Chapter 5: Configuration Decoded (ISCP) RSS Code (Reduced Space Symbology)

5.14.3.18 RSS Code (Reduced Space Symbology) Enable Setting this parameter to on enables “RSS Code” scanning capability. Enable RSS-14 RSS-14 code can be either purely linear or split in half with one half stacked on top of the other half. Stacking the code reduces the bar code length, and providing the nominal height of the code is maintained, it can be omni-directionally scanned. Enable RSS Limited “RSS-Limited” is restricted, in that it can only encode 14 digit GTINs (global trade item number) that begin with either a 0 or a 1. It is not stackable and is not designed to be read omni-directionally. Enable RSS Expanded “RSS Expanded” uses the same application identifiers as UCC/EAN-128 codes but they can be split into sections and stacked several rows high, reducing the length of the symbol, while increasing the capacity of data that can be stored. “RSS Expanded” code can be omnidirectionally scanned. Field Size/Chars Refer to “Field Size/Chars” on page 170 for details. 5.14.3.19 PDF-417 Enabled Set this parameter to on to enable “PDF-417”. Field Size/Chars Refer to “Field Size/Chars” on page 170 for details. 5.14.3.20 Micro PDF-417 Enabled Set this parameter to on to enable “Micro PDF-417”. Code 128 Emulation When this parameter is enabled, the scanner transmits data from certain Micro PDF-417 symbols as if it was encoded in Code 128 symbols. Ikôn Rugged PDA (Windows CE 5.0) User Manual