Catalogo UHF-VHF 13

Page 1


VHF-UHF Filters and Combiners - Catalogue 13

Via Senatore Simonetta,26 20867 Caponago (MB) - Italy tel.: +39 02.95.96.11 fax +39 02.95.96.13.11 e-mail: info@sira.mi.it www.sira.mi.it


200


history SIRA SIRA is a privately owned company, founded in 1977 by a group of technicians active in the telecommunication field and specialized in RF technology. Sira has 11,000 sq.meters of manufacturing and support facility based in Caponago (MI) Italy. SIRA is a customer oriented company, which has adopted the philosophy of working together with its customers to meet the critical technical requirements for their systems with an attitude of enthusiasm and concern in order to provide the best results in the final products. This approach has given Sira a position of leadership in its field. Sira products are designed and manufactured in accordance with the particular international standards in force in the area. As a major position of its cross revenues, Sira has been investing in research and development, quality and reliability control and products safety in the RF field. This policy of investments has provided Sira with an extremely high level of experience in its field: there are Sira installations in more than 80 countries in the world.

1


quality

SIRA’s aim is to give to all its customers reliable products and services with the highest quality standards, this ambitious goal is achieved mainly by means of an integrated management system (Quality-Safety-environment) and is certified according to the norms UNI EN ISO 9001 (2000) and UNI EN 14001 (1996). The enhancement of company efficiency through the continuous improvement of the operative quality of the internal functions (effectiveness), the reduction of defects on sold products and the notable attention to the quality culture at all company levels have become SIRA’s fundamental cares. Moreover SIRA is committed in a thorough policy of environmental protection: a training and information process on all personnel is continuously carried out in order to grant a responsible management of all the activities in a special respect of the environment. For instance, the development and the implementation of new technologies, products and production processes is carried out with a thorough control for a rational use of energetic sources and of raw materials, minimizing the production of waste and the use of non-renewable resources, everything with the aim of keeping environmental impact on air and water as lowest as it is possible. For all SIRA’s activities it is fundamental to oppose the conditions of life and work which are against the health of the workers, as well as promoting freedom principles and self-respect for any human being. An extract from SIRA’s ethic code states that “Sira refuses any discrimination based on sex, race, languages, personal and social conditions, religion and political choices” and to this aim Sira promotes a working environment that, inspired to the principles of respect, fairness and collaboration, is meant to support the involvement of all Employees and Contributors giving the common sense of responsibility in reaching all the Company goals.

2


index

VHF BIII Filters

5

VHF DAB Filters

11

UHF ATV Filters

17

UHF DTV Filters

29

VHF BIII Combiners

49

VHF DAB Combiners

57

UHF ATV Combiners

63

UHF DTV Combiners

83

Coaxial Components

109

3



VHF BIII FILTERS

VHF BIII Filters

CTV/B3/DVB6-2.5

7

CTV/B3/DVB6-5

8

CTV/B3/DVB6-10

9

CTV/B3/DVB8-5

5

10



CTV/B3/DVB6-2.5

VHF BIII FILTERS

VHF BIII DTV BANDPASS FILTER

FEATURES VHF BIII 2.5 kW Digital TV bandpass filter DVB/ATSC applications 6 Pole elliptical response / 120 mm tunable within the whole VHF BIII range temperature compensated SMA output monitor probe (optional)

162 ÷ 254 MHz 2.5 kW DTV (3.75 kW ATV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 2.5 kW DTV 26 Kg

MAX 770

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS DD

2 x 1-5/8” Unfl.

* referred to DVB-T 7 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 7 MHz Mask ≤ 0.25 dB at C.F. ≤ 0.75 dB at C.F. ± 3.325 MHz ≥ 4 dB at C.F. ± 3.675 MHz ≥ 16 dB at C.F. ± 5.25 MHz ≥ 42 dB at C.F. ± 10.5 MHz > 26 dB ≤ 400 ns (Typical)

ATSC 6 MHz Mask ≤ 0.35 dB at C.F. ≤ 0.77 dB at C.F. ± 2.7 MHz ≥ 3 dB at C.F. ± 3.5 MHz ≥ 29 dB at C.F. ± 6 MHz ≥ 38 dB at C.F. ± 9 MHz > 26 dB ≤ 350 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

7

281

ELECTRICAL DATA

448


CTV/B3/DVB6-5 VHF BIII DTV BANDPASS FILTER

VHF BIII 5 kW Digital TV bandpass filter DVB/ATSC applications 6 Pole elliptical response / 150 mm tunable within the whole VHF BIII range temperature compensated SMA output monitor probe (optional)

162 ÷ 254 MHz 5 kW DTV (7.5 kW ATV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 5 kW DTV 33 Kg

MAX 770

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS DD

2 x 1-5/8” Unfl.

* referred to DVB-T 7 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 7 MHz Mask ≤ 0.24 dB at C.F. ≤ 0.70 dB at C.F. ± 3.325 MHz ≥ 4 dB at C.F. ± 3.675 MHz ≥ 16 dB at C.F. ± 5.25 MHz ≥ 42 dB at C.F. ± 10.5 MHz ≥ 26 dB ≤ 300 ns (Typical)

ATSC 6 MHz Mask ≤ 0.30 dB at C.F. ≤ 0.55 dB at C.F. ± 2.7 MHz ≥ 3 dB at C.F. ± 3.5 MHz ≥ 29 dB at C.F. ± 6 MHz ≥ 38 dB at C.F. ± 9 MHz ≥ 26 dB ≤ 350 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

8

343

VHF BIII FILTERS

FEATURES

526


CTV/B3/DVB6-10

VHF BIII FILTERS

VHF BIII DTV BANDPASS FILTER

FEATURES VHF BIII 10 kW Digital TV bandpass filter DVB/ATSC applications 6 Pole elliptical response / 200 mm tunable within the whole VHF BIII range temperature compensated SMA output monitor probe (optional)

162 ÷ 254 MHz 10 kW DTV (15 kW ATV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 10 kW DTV 59 Kg

MAX 780

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS EE

2 x 3-1/8” Unfl.

* referred to DVB-T 7 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 7 MHz Mask ≤ 0.17 dB at C.F. ≤ 0.49 dB at C.F. ± 3.325 MHz ≥ 4 dB at C.F. ± 3.675 MHz ≥ 16 dB at C.F. ± 5.25 MHz ≥ 42 dB at C.F. ± 10.5 MHz ≥ 26 dB ≤ 300 ns (Typical)

ATSC 6 MHz Mask ATSC 6 MHz Mask ≤ 0.23 dB at C.F. ≤ 0.39 dB at C.F. ± 2.7 MHz ≥ 3 dB at C.F. ± 3.5 MHz ≥ 29 dB at C.F. ± 6 MHz ≥ 38 dB at C.F. ± 9 MHz ≥ 26 dB ≤ 350 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

9

418

ELECTRICAL DATA

744


CTV/B3/DVB8-5 VHF BIII DTV BANDPASS FILTER

VHF BIII 5 kW Digital TV bandpass filter DVB/ATSC applications 8 Pole elliptical response / 150 mm tunable within the whole VHF BIII range temperature compensated SMA output monitor probe (optional)

162 ÷ 254 MHz 5 kW DTV (7.5 kW ATV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 5 kW DTV 46 Kg

MAX 770

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS DD

2 x 1-5/8” Unfl. * referred to DVB-T 7 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 7 MHz Mask ≤ 0.30 dB at C.F. ≤ 0.85 dB at C.F. ± 3.325 MHz ≥ 14 dB at C.F. ± 3.675 MHz ≥ 26 dB at C.F. ± 5.25 MHz ≥ 55 dB at C.F. ± 10.5 MHz ≥ 26 dB ≤ 550 ns (Typical)

343

VHF BIII FILTERS

FEATURES

676

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

10


CTV/B3/DAB6-0.6

13

CTV/B3/DAB6-1.2

14

CTV/B3/DAB6-2.5

15

SpeciямБcations are subject to change without prior notice

11

VHF DAB FILTERS

VHF DAB Filters



CTV/B3/DAB6-0.6 VHF BIII DAB BANDPASS FILTER

FEATURES

174 ÷ 240 MHz 600 W 1.54 MHz ≤ 1 kHz/K -10 to + 50°C 30K at 600 W 26 Kg MAX 750

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS BB CC DD

VHF DAB FILTERS

VHF BIII 600 W DAB bandpass filter DAB/T-DMB applications 6 Pole elliptical response / 120 mm tunable within the whole VHF BIII DAB range temperature compensated SMA output monitor probe (optional)

2 x 7/16 F 2 x 7/8” Unfl. 2 x 1-5/8” Unfl.

* referred to DAB block 12D, C.M.1 standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DAB C.M.1 ≤ 1.05 dB at C.F. ≤ 2.5 dB at C.F. ± 0.77 MHz ≥ 15 dB at C.F. ± 0.97 MHz ≥ 45 dB at C.F. ± 1.75 MHz ≥ 45 dB at C.F. ± 2.2 MHz ≥ 45 dB at C.F. ± 3 MHz ≥ 26 dB ≤ 950 ns (Typical)

DAB C.M.2 ≤ 1.05 dB at C.F. ≤ 2.3 dB at C.F. ± 0.77 MHz ≥ 10 dB at C.F. ± 0.97 MHz ≥ 40 dB at C.F. ± 1.75 MHz ≥ 40 dB at C.F. ± 2.2 MHz ≥ 40 dB at C.F. ± 3 MHz ≥ 26 dB ≤ 800 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating DAB block number

Specifications are subject to change without prior notice

13

281

ELECTRICAL DATA

375


CTV/B3/DAB6-1.2 VHF BIII DAB BANDPASS FILTER

FEATURES

174 ÷ 240 MHz 1.2 kW 1.54 MHz ≤ 1 kHz/K -10 to + 50°C 30K at 1.2 kW 33 Kg MAX 750

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS BB CC DD

2 x 7/16 F 2 x 7/8” Unfl. 2 x 1-5/8” Unfl.

* referred to DAB block 12D, C.M.1 standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DAB C.M.1 ≤ 0.85 dB at C.F. ≤ 2.0 dB at C.F. ± 0.77 MHz ≥ 15 dB at C.F. ± 0.97 MHz ≥ 45 dB at C.F. ± 1.75 MHz ≥ 45 dB at C.F. ± 2.2 MHz ≥ 45 dB at C.F. ± 3 MHz ≥ 26 dB ≤ 950 ns (Typical)

DAB C.M.2 ≤ 0.85 dB at C.F. ≤ 1.9 dB at C.F. ± 0.77 MHz ≥ 10 dB at C.F. ± 0.97 MHz ≥ 40 dB at C.F. ± 1.75 MHz ≥ 40 dB at C.F. ± 2.2 MHz ≥ 40 dB at C.F. ± 3 MHz ≥ 26 dB ≤ 800 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating DAB block number Specifications are subject to change without prior notice

14

343

VHF DAB FILTERS

VHF BIII 1.2 kW DAB bandpass filter DAB/T-DMB applications 6 Pole elliptical response / 150 mm tunable within the whole VHF BIII DAB range temperature compensated SMA output monitor probe (optional)

452


CTV/B3/DAB6-2.5 VHF BIII DAB BANDPASS FILTER

FEATURES

174 ÷ 240 MHz 2.5 kW 1.54 MHz ≤ 1 kHz/K -10 to + 50°C 30K at 2.5 kW 56 kg

MAX 750

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS DD EE

VHF DAB FILTERS

VHF BIII 2.5 kW DAB bandpass filter DAB/T-DMB applications 6 Pole elliptical response / 200 mm tunable within the whole VHF BIII DAB range temperature compensated SMA output monitor probe (optional)

2 x 1-5/8” Unfl. 2 x 3-1/8” Unfl.

* referred to DAB block 12D, C.M.1 standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DAB C.M.1 ≤ 0.6 dB at C.F. ≤ 1.5 dB at C.F. ± 0.77 MHz ≥ 15 dB at C.F. ± 0.97 MHz ≥ 45 dB at C.F. ± 1.75 MHz ≥ 45 dB at C.F. ± 2.2 MHz ≥ 45 dB at C.F. ± 3 MHz ≥ 26 dB ≤ 950 ns (Typical)

DAB C.M.2 ≤ 0.6 dB at C.F. ≤ 1.5 dB at C.F. ± 0.77 MHz ≥ 10 dB at C.F. ± 0.97 MHz ≥ 40 dB at C.F. ± 1.75 MHz ≥ 40 dB at C.F. ± 2.2 MHz ≥ 40 dB at C.F. ± 3 MHz ≥ 26 dB ≤ 800 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating DAB block number Specifications are subject to change without prior notice

15

418

ELECTRICAL DATA

702



CTV/U3-03

19

CTV/U3-075

20

CTV/U32-075

21

CTV/U4-03

22

CTV/U4-075

23

CTV/U4-1.5

24

CTV/U4-3

25

CTV/U4-7.5

26

CTV/U4-15

27

SpeciямБcations are subject to change without prior notice

17

UHF ATV FILTERS

UHF ATV Filters



CTV/U3-03 UHF ATV BANDPASS FILTER

FEATURES

UHF ATV FILTERS

UHF 300 W Analog TV bandpass filter 3 Pole / 40 mm tunable within the whole UHF range

470 ÷ 862 MHz 300 W ATV (100 W DTV) 6 to 8 MHz ≤15 kHz/K -10 to + 50°C 40K at 300 W ATV 0.7 Kg

132

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS AA

2 x NF

126

* referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS GROUP DELAY VARIATION

CCIR G Standard ≤ 0.60 dB at C.F. ≥ 3 dB at V.C. -5.5/+11 MHz ≥ 12 dB at V.C. -11/+16.5 MHz ≥ 26 dB ≤ 25 ns (Typical)

FCC M Standard ≤ 0.70 dB at C.F. ≥ 3 dB at V.C. -4.5/+9 MHz ≥ 12 dB at V.C. -9/+13.5 MHz ≥ 26 dB ≤ 25 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

19

41


CTV/U3-075 UHF ATV BANDPASS FILTER

FEATURES UHF 750 W Analog TV bandpass filter 3 Pole / 50 mm tunable within the whole UHF range SMA output monitor probe (optional)

156

UHF ATV FILTERS

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS BB

470 ÷ 862 MHz 750 W ATV (250 W DTV) 6 to 8 MHz ≤15 kHz/K -10 to + 50°C 35K at 750 W ATV 1.25 Kg 2 x 7/16 F

224

* referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS GROUP DELAY VARIATION

CCIR G Standard ≤ 0.45 dB at C.F. ≥ 3 dB at V.C. -5.5/+11 MHz ≥ 12 dB at V.C. -11/+16.5 MHz ≥ 26 dB ≤ 25 ns (Typical)

FCC M Standard ≤ 0.55 dB at C.F. ≥ 3 dB at V.C. -4.5/+9 MHz ≥ 12 dB at V.C. -9/+13.5 MHz ≥ 26 dB ≤ 25 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

20

57


CTV/U32-075 UHF ATV BANDPASS FILTER

FEATURES

160

UHF ATV FILTERS

UHF 750 kW Analog TV bandpass filter 3 Pole + 2 notch / 50 mm tunable within the whole UHF range SMA output monitor probe (optional)

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS BB

470 ÷ 862 MHz 750 W ATV (250 W DTV) 6 to 8 MHz ≤15 kHz/K -10 to + 50°C 35K at 750 W ATV 1.6 Kg 2 x 7/16 F

278

* referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS GROUP DELAY VARIATION

CCIR G Standard ≤ 0.40 dB at C.F. ≥ 30 dB at V.C. -5.5/+11 MHz ≥ 13 dB at V.C. -11/+16.5 MHz ≥ 26 dB ≤ 25 ns (Typical)

FCC M Standard ≤ 0.50 dB at C.F. ≥ 30 dB at V.C. -4.5/+9 MHz ≥ 13 dB at V.C. -9/+13.5 MHz ≥ 26 dB ≤ 25 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

21

57


CTV/U4-03 UHF ATV BANDPASS FILTER

FEATURES UHF 300 W Analog TV bandpass filter 4 Pole / 40 mm tunable within the whole UHF range

132

UHF ATV FILTERS

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS AA

470 ÷ 862 MHz 300 W ATV (100 W DTV) 6 to 8 MHz ≤15 kHz/K -10 to + 50°C 40K at 300 W ATV 0.9 Kg 2 x NF

166

* referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS GROUP DELAY VARIATION

CCIR G Standard ≤ 0.80 dB at C.F. ≥ 8 dB at V.C. -5.5/+11 MHz ≥ 25 dB at V.C. -11/+16.5 MHz ≥ 26 dB ≤ 35 ns (Typical)

FCC M Standard ≤ 0.95 dB at C.F. ≥ 8 dB at V.C. -4.5/+9 MHz ≥ 25 dB at V.C. -9/+13.5 MHz ≥ 26 dB ≤ 35 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

22

41


CTV/U4-075 UHF ATV BANDPASS FILTER

FEATURES

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS BB

156

UHF ATV FILTERS

UHF 750 W Analog TV bandpass filter 4 Pole / 50 mm tunable within the whole UHF range SMA output monitor probe (optional)

470 ÷ 862 MHz 750 W ATV (250 W DTV) 6 to 8 MHz ≤15 kHz/K -10 to + 50°C 35K at 750 W ATV 1.3 Kg 2 x 7/16 F

224

* referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS GROUP DELAY VARIATION

CCIR G Standard ≤ 0.70 dB at C.F. ≥ 8 dB at V.C. -5.5/+11 MHz ≥ 25 dB at V.C. -11/+16.5 MHz ≥ 26 dB ≤ 35 ns (Typical)

FCC M Standard ≤ 0.85 dB at C.F. ≥ 8 dB at V.C. -4.5/+9 MHz ≥ 25 dB at V.C. -9/+13.5 MHz ≥ 26 dB ≤ 35 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

23

57


CTV/U4-1.5 UHF ATV BANDPASS FILTER

FEATURES UHF 1.5 kW Analog TV bandpass filter 4 Pole elliptical response / 85 mm tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

UHF ATV FILTERS

470 ÷ 862 MHz 1.5 kW ATV (500W DTV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 35K at 1.5 kW ATV 4 Kg

223

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS BB CC DD

2 x 7/16 F 2 x 7/8” EIA 2 x 1-5/8” Unfl. * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS GROUP DELAY

CCIR G Standard ≤ 0.35 dB at C.F. ≥ 40 dB at V.C. -5.5/+11 MHz ≥ 24 dB at V.C. -11/+16.5 MHz ≥ 26 dB ≤ 45 ns (Typical)

FCC M Standard ≤ 0.40 dB at C.F. ≥ 40 dB at V.C. -4.5/+9 MHz ≥ 24 dB at V.C. -9/+13.5 MHz ≥ 26 dB ≤ 45 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

24

164

ELECTRICAL DATA

172


CTV/U4-3 UHF ATV BANDPASS FILTER

FEATURES

UHF ATV FILTERS

UHF 3 kW Analog TV bandpass filter 4 Pole elliptical response / 120 mm tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

470 ÷ 862 MHz 3 kW ATV (1 kW DTV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 35K at 3kW ATV 6 Kg

302

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS CC DD

2 x 7/8” EIA 2 x 1-5/8” Unfl. * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS GROUP DELAY VARIATION

CCIR G Standard ≤ 0.25 dB at C.F. ≥ 40 dB at V.C. -5.5/+11 MHz ≥ 24 dB at V.C. -11/+16.5 MHz ≥ 26 dB ≤ 45 ns (Typical)

FCC M Standard ≤ 0.30 dB at C.F. ≥ 40 dB at V.C. -4.5/+9 MHz ≥ 24 dB at V.C. -9/+13.5 MHz ≥ 26 dB ≤ 45 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

25

175

ELECTRICAL DATA

242


CTV/U4-7.5 UHF ATV BAND PASS FILTER

FEATURES UHF 7.5 kW Analog TV bandpass filter 4 Pole elliptical response / 150 mm tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

UHF ATV FILTERS

470 ÷ 862 MHz 7.5 kW ATV (3.75 kW DTV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 45K at 7.5 kW ATV 15 Kg

372

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS DD EE

MAX 380

2 x 1-5/8” Unfl 2 x 3-1/8” Unfl * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS GROUP DELAY

CCIR G Standard ≤ 0.20 dB at C.F. ≥ 40 dB at V.C. -5.5/+11 MHz ≥ 24 dB at V.C. -11/+16.5 MHz ≥ 26 dB ≤ 45 ns (Typical)

FCC M Standard ≤ 0.25 dB at C.F. ≥ 40 dB at V.C. -4.5/+9 MHz ≥ 24 dB at V.C. -9/+13.5 MHz ≥ 26 dB ≤ 45 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

26

302


CTV/U4-15 UHF ATV BANDPASS FILTER

FEATURES

UHF ATV FILTERS

UHF 15 kW Analog TV bandpass filter 4 Pole elliptical response / 200 mm tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

470 ÷ 862 MHz 15 kW ATV (7.5 kW DTV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 40K at 15 kW ATV 28 Kg

464

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS DD EE

MAX 440

2 x 1-5/8” Unfl 2 x 3-1/8” Unfl * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS GROUP DELAY VARIATION

CCIR G Standard ≤ 0.15 dB at C.F. ≥ 40 dB at V.C. -5.5/+11 MHz ≥ 24 dB at V.C. -11/+16.5 MHz ≥ 26 dB ≤ 45 ns (Typical)

FCC M Standard ≤ 0.15 dB at C.F. ≥ 40 dB at V.C. -4.5/+9 MHz ≥ 24 dB at V.C. -9/+13.5 MHz ≥ 26 dB ≤ 45 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

27

418



CTV/U/DVB5-01

31

CTV/U/DVB5-025

32

CTV/U/DVB6-01

33

CTV/U/DVB6-025

34

CTV/U/DVB6-025/F

35

CTV/U/DVB6-05

36

CTV/U/DVB6-1

37

CTV/U/DVB6-2.5

38

CTV/U/DVB6-5

39

CTV/U/DVB6-10/LC

40

CTV/U/DVB8-005

41

CTV/U/DVB8-020

42

CTV/U/DVB8-05

43

CTV/U/DVB8-1

44

CTV/U/DVB8-2.5

45

CTV/U/DVB8-5

46

CTV/U/DVB8-10/LC

47

SpeciямБcations are subject to change without prior notice

29

UHF DTV FILTERS

UHF DTV Filters



CTV/U/DVB5-01 UHF DTV BANDPASS FILTER

FEATURES

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS AA

132

UHF DTV FILTERS

UHF 100 W Digital TV bandpass filter DVB/ATSC applications 5 Pole / 40 mm tunable within the whole UHF range temperature compensated

470 ÷ 862 MHz 100 W DTV (150 W ATV) 6 to 8 MHz ≤10 kHz/K -10 to + 50°C 30K at 100 W DTV 1.1 Kg

204

2 x NF * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS GROUP DELAY

DVB 8 MHz Mask ≤ 1.20 dB at C.F. ≤ 1.70 dB at C.F. ± 3.8 MHz ≥ 7 dB at C.F.. ±6MHz ≥ 36 dB at C.F. ±12MHz ≥ 26 dB ≤ 80 ns (Typical)

ATSC 6 MHz Mask ≤ 1.30 dB at C.F. ≤ 1.60 dB at C.F. ± 2.7 MHz ≥ 7 dB at C.F. ±6MHz ≥ 28 dB at C.F. ±9MHz ≥ 26 dB ≤ 80 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

31

41


CTV/U/DVB5-025 UHF DTV BANDPASS FILTER

FEATURES UHF 250 W Digital TV bandpass filter DVB/ATSC applications 5 Pole / 50 mm tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

156

UHF DTV FILETRS

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS BB

470 ÷ 862 MHz 250 W DTV (375 W ATV) 6 to 8 MHz ≤10 kHz/K -10 to + 50°C 30K at 250 W DTV 1.4 Kg

278

2 x 7/16 F * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS GROUP DELAY

DVB 8 MHz Mask ≤ 1.0 dB at C.F. ≤ 1.50 dB at C.F. ± 3.8 MHz ≥ 7 dB at C.F. ±6MHz ≥ 36 dB at C.F. ±12MHz ≥ 26 dB ≤ 80 ns (Typical)

ATSC 6 MHz Mask ≤ 1.10 dB at C.F. ≤ 1.40 dB at C.F. ± 2.7 MHz ≥ 7 dB at C.F. ±6MHz ≥ 26 dB at C.F. ±9MHz ≥ 26 dB ≤ 80 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

32

57


CTV/U/DVB6-01 UHF DTV BANDPASS FILTER

FEATURES

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS AA

132

UHF DTV FILTERS

UHF 100 W Digital TV bandpass filter DVB/ATSC applications 6 Pole / 40 mm tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

470 ÷ 862 MHz 100 W DTV (150 W ATV) 6 to 8 MHz ≤10 kHz/K -10 to + 50°C 30K at 100 W DTV 1.3 Kg 2 x NF

243

* referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 8 MHz Mask ≤ 1.4 dB at C.F. ≤ 1.9 dB at C.F. ± 3.8 MHz ≥ 2 dB at C.F. ± 4.2 MHz ≥ 12 dB at C.F. ± 6 MHz ≥ 36 dB at C.F. ± 12 MHz ≥ 26 dB ≤ 150 ns (Typical)

ATSC 6 MHz Mask ≤ 1.6 dB at C.F. ≤ 2.2 dB at C.F. ± 2.7 MHz ≥ 4 dB at C.F. ± 3.5 MHz ≥ 12 dB at C.F. ± 6 MHz ≥ 36 dB at C.F. ± 9 MHz ≥ 26 dB ≤ 150 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

33

41


CTV/U/DVB6-025 UHF DTV BANDPASS FILTER

FEATURES UHF 250 W Digital TV bandpass filter DVB/ATSC applications 6 Pole / 50 mm tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

156

UHF DTV FILETRS

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS BB

470 ÷ 862 MHz 250 W DTV (375 W ATV) 6 to 8 MHz ≤10 kHz/K -10 to + 50°C 30K at 250 W DTV 1.7 Kg 2 x 7/16 F

329

* referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 8 MHz Mask ≤ 1.10 dB at C.F. ≤ 1.80 dB at C.F. ± 3.8 MHz ≥ 2 dB at C.F. ± 4.2 MHz ≥ 12 dB at C.F. ± 6 MHz ≥ 36 dB at C.F. ± 12 MHz ≥ 26 dB ≤ 150 ns (Typical)

ATSC 6 MHz Mask ≤ 1.30 dB at C.F. ≤ 2.00 dB at C.F. ± 2.7 MHz ≥ 4 dB at C.F. ± 3.5 MHz ≥ 12 dB at C.F. ± 6 MHz ≥ 36 dB at C.F. ± 9 MHz ≥ 26 dB ≤ 150 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

34

57


CTV/U/DVB6-025/F UHF DTV BANDPASS FILTER

FEATURES

UHF DTV FILTERS

UHF 250 W Digital TV bandpass filter DVB/ATSC applications 6 Pole / 50 mm elliptical response tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

470 ÷ 862 MHz 250 W DTV (375 W ATV) 6 to 8 MHz ≤ 4 kHz/K -10 to + 50°C 30K at 250 W DTV 1.7 Kg

191

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS BB

2 x 7/16 F

* referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 8 MHz Mask ≤ 0.90 dB at C.F. ≤ 2.20 dB at C.F. ± 3.8 MHz ≥ 4 dB at C.F. ± 4.2 MHz ≥ 16 dB at C.F. ± 6 MHz ≥ 42 dB at C.F. ± 12 MHz ≥ 26 dB ≤ 250 ns (Typical)

ATSC 6 MHz Mask ≤ 1.50 dB at C.F. ≤ 2.70 dB at C.F. ± 2.7 MHz ≥ 6 dB at C.F. ± 3.5 MHz ≥ 25 dB at C.F. ± 6 MHz ≥ 45 dB at C.F. ± 9 MHz ≥ 26 dB ≤ 150 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

35

140

ELECTRICAL DATA

113


CTV/U/DVB6-05 UHF DTV BANDPASS FILTER

FEATURES UHF 500 W Digital TV bandpass filter DVB/ATSC applications 6 Pole / 85 mm elliptical response tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

UHF DTV FILETRS

470 ÷ 862 MHz 500 W DTV (750 W ATV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 500 W DTV 5 Kg

288

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS BB CC DD

2 x 7/16 F 2 x 7/8” EIA 2 x 1-5/8” Unfl * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 8 MHz Mask ≤ 0.45 dB at C.F. ≤ 1.45 dB at C.F. ± 3.8 MHz ≥ 4 dB at C.F. ± 4.2 MHz ≥ 16 dB at C.F. ± 6 MHz ≥ 42 dB at C.F. ± 12 MHz ≥ 26 dB ≤ 250 ns (Typical)

ATSC 6 MHz Mask ≤ 0.70 dB at C.F. ≤ 1.30 dB at C.F. ± 2.7 MHz ≥ 6 dB at C.F. ± 3.5 MHz ≥ 25 dB at C.F. ± 6 MHz ≥ 45 dB at C.F. ± 9 MHz ≥ 26 dB ≤ 150 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

36

179

ELECTRICAL DATA

172


CTV/U/DVB6-1 UHF DTV BANDPASS FILTER

FEATURES

UHF DTV FILTERS

UHF 1 kW Digital TV bandpass filter DVB/ATSC applications 6 Pole / 120 mm elliptical response tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

470 ÷ 862 MHz 1 kW DTV (1.5 kW ATV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 1 kW DTV 9 Kg

409

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS BB CC DD

2 x 7/16 F 2 x 7/8”EIA 2 x 1-5/8” Unfl * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 8 MHz Mask ≤ 0.40 dB at C.F. ≤ 1.25 dB at C.F. ± 3.8 MHz ≥ 4 dB at C.F. ± 4.2 MHz ≥ 16 dB at C.F. ± 6 MHz ≥ 42 dB at C.F. ± 12 MHz ≥ 26 dB ≤ 250 ns (Typical)

ATSC 6 MHz Mask ≤ 0.60 dB at C.F. ≤ 1.00 dB at C.F. ± 2.7 MHz ≥ 6 dB at C.F. ± 3.5 MHz ≥ 25 dB at C.F. ± 6 MHz ≥ 45 dB at C.F. ± 9 MHz ≥ 26 dB ≤ 150 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

37

240

ELECTRICAL DATA

250


CTV/U/DVB6-2.5 UHF DTV BANDPASS FILTER

FEATURES UHF 2.5 kW Digital TV bandpass filter DVB/ATSC applications 6 Pole / 150 mm elliptical response tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

UHF DTV FILETRS

470 ÷ 862 MHz 2.5 kW DTV (3.75 kW ATV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 2.5 kW DTV 18.5 Kg

518

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS DD EE

2 x 1-5/8” Unfl 2 x 3-1/8” Unfl * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 8 MHz Mask ≤ 0.30 dB at C.F. ≤ 1.10 dB at C.F. ± 3.8 MHz ≥ 4 dB at C.F. ± 4.2 MHz ≥ 16 dB at C.F. ± 6 MHz ≥ 42 dB at C.F. ± 12 MHz ≥ 26 dB ≤ 250 ns (Typical)

ATSC 6 MHz Mask ≤ 0.50 dB at C.F. ≤ 0.90 dB at C.F. ± 2.7 MHz ≥ 6 dB at C.F. ± 3.5 MHz ≥ 25 dB at C.F. ± 6 MHz ≥ 45 dB at C.F. ± 9 MHz ≥ 26 dB ≤ 150 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

38

MAX 485

ELECTRICAL DATA

302


CTV/U/DVB6-5 UHF DTV BANDPASS FILTER

FEATURES

UHF DTV FILTERS

UHF 5 kW Digital TV bandpass filter DVB/ATSC applications 6 Pole / 200 mm elliptical response tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

470 ÷ 862 MHz 5 kW DTV (7.5 kW ATV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 25K at 5 kW DTV 40 Kg

744

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS DD EE

2 x 1-5/8” Unfl 2 x 3-1/8” Unfl * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 8 MHz Mask ≤ 0.25 dB at C.F. ≤ 0.70 dB at C.F. ± 3.8 MHz ≥ 4 dB at C.F. ± 4.2 MHz ≥ 16 dB at C.F. ± 6 MHz ≥ 42 dB at C.F. ± 12 MHz ≥ 26 dB ≤ 250 ns (Typical)

ATSC 6 MHz Mask ≤ 0.30 dB at C.F. ≤ 0.50 dB at C.F. ± 2.7 MHz ≥ 6 dB at C.F. ± 3.5 MHz ≥ 25 dB at C.F. ± 6 MHz ≥ 45 dB at C.F. ± 9 MHz ≥ 26 dB ≤ 150 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

39

MAX 440

ELECTRICAL DATA

418


CTV/U/DVB6-10/LC UHF DTV BANDPASS FILTER

FEATURES UHF 10 kW Digital TV bandpass filter DVB/ATSC applications 6 Pole / 200 mm elliptical response tunable within the whole UHF range temperature compensated SMA output monitor probe (optional) liquid cooled

UHF DTV FILETRS

470 ÷ 862 MHz 10 kW DTV (15 kW ATV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 10 kW DTV 42 Kg

744

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS DD EE

2 x 1-5/8” Unfl 2 x 3-1/8” Unfl * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 8 MHz Mask ≤ 0.25 dB at C.F. ≤ 0.70 dB at C.F. ± 3.8 MHz ≥ 4 dB at C.F. ± 4.2 MHz ≥ 16 dB at C.F. ± 6 MHz ≥ 42 dB at C.F. ± 12 MHz ≥ 26 dB ≤ 250 ns (Typical)

ATSC 6 MHz Mask ≤ 0.30 dB at C.F. ≤ 0.50 dB at C.F. ± 2.7 MHz ≥ 6 dB at C.F. ± 3.5 MHz ≥ 25 dB at C.F. ± 6 MHz ≥ 45 dB at C.F. ± 9 MHz ≥ 26 dB ≤ 150 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

40

MAX 440

ELECTRICAL DATA

418


CTV/U/DVB8-005 UHF DTV BANDPASS FILTER

FEATURES

UHF DTV FILTERS

UHF 50 W Digital TV bandpass filter DVB applications 8 Pole / 40 mm elliptical response tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

470 ÷ 862 MHz 50 W DTV (75 W ATV) 6 to 8 MHz ≤10 kHz/K -10 to + 50°C 30K at 50 W DTV 1.9 Kg

132

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS AA

2 x NF

* referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA

SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 8 MHz Mask ≤ 2 dB at C.F. ≤ 4.95 dB at C.F. ± 3.8 MHz ≥ 12 dB at C.F. ± 4.2 MHz ≥ 30 dB at C.F. ± 6 MHz ≥ 55 dB at C.F. ± 12 MHz ≥ 26 dB ≤ 450 ns (Typical)

166

INSERTION LOSS (Typical)**

81

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

41


CTV/U/DVB8-020 UHF DTV BANDPASS FILTER

FEATURES UHF 200 W Digital TV bandpass filter DVB/ATSC applications 8 Pole / 50 mm elliptical response tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

UHF DTV FILETRS

470 ÷ 862 MHz 200 W DTV (300 W ATV) 6 to 8 MHz ≤ 4 kHz/K -10 to + 50°C 30K at 200 W DTV 2.6 Kg

250

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS BB

2 x 7/16 F

* referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 8 MHz Mask ≤ 1.5 dB at C.F. ≤ 4.5 dB at C.F. ± 3.8 MHz ≥ 12 dB at C.F. ± 4.2 MHz ≥ 30 dB at C.F. ± 6 MHz ≥ 55 dB at C.F. ± 12 MHz ≥ 26 dB ≤ 450 ns (Typical)

ATSC 6 MHz Mask ≤ 1.80 dB at C.F. ≤ 5.20 dB at C.F. ±2.85 MHz ≥ 14 dB at C.F. ±3.15 MHz ≥ 30 dB at C.F. ±4.5 MHz ≥ 50 dB at C.F. ±9 MHz ≥ 26 dB ≤ 450 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

42

140

ELECTRICAL DATA

113


CTV/U/DVB8-05 UHF DTV BANDPASS FILTER

FEATURES

UHF DTV FILTERS

UHF 500 W Digital TV bandpass filter DVB/ATSC applications 8 Pole / 85 mm elliptical response tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

470 ÷ 862 MHz 500 W DTV (750 W ATV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 500 W DTV 6.5 kg

399

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS BB CC DD

2 x 7/16 F 2 x 7/8” EIA 2 x 1-5/8” Unfl

* referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 8 MHz Mask ≤ 0.85 dB at C.F. ≤ 3.00 dB at C.F. ± 3.8 MHz ≥ 12 dB at C.F. ± 4.2 MHz ≥ 30 dB at C.F. ± 6 MHz ≥ 55 dB at C.F. ± 12 MHz ≥ 26 dB ≤ 450 ns (Typical)

ATSC 6 MHz Mask ≤ 1.00 dB at C.F. ≤ 3.85 dB at C.F. ±2.85 MHz ≥ 14 dB at C.F. ±3.15 MHz ≥ 30 dB at C.F. ±4.5 MHz ≥ 50 dB at C.F. ±9 MHz ≥ 26 dB ≤ 450 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

43

179

ELECTRICAL DATA

172


CTV/U/DVB8-1 UHF DTV BANDPASS FILTER

FEATURES UHF 1 kW Digital TV bandpass filter DVB/ATSC applications 8 Pole / 120 mm elliptical response tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

UHF DTV FILETRS

470 ÷ 862 MHz 1 kW DTV (1.5 kW ATV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 1 kW DTV 12 kg

569

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS BB CC DD

2 x 7/16 F 2 x 7/8’’ EIA 2 x 1-5/8’’ Unfl * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 8 MHz Mask ≤ 0.65 dB at C.F. ≤ 2.5 dB at C.F. ± 3.8 MHz ≥ 12 dB at C.F. ± 4.2 MHz ≥ 30 dB at C.F. ± 6 MHz ≥ 55 dB at C.F. ± 12 MHz ≥ 26 dB ≤ 450 ns (Typical)

ATSC 6 MHz Mask ≤ 0.80 dB at C.F. ≤ 3.45 dB at C.F. ±2.85 MHz ≥ 14 dB at C.F. ±3.15 MHz ≥ 30 dB at C.F. ±4.5 MHz ≥ 50 dB at C.F. ±9 MHz ≥ 26 dB ≤ 450 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

44

240

ELECTRICAL DATA

250


CTV/U/DVB8-2.5 UHF DTV BANDPASS FILTER

FEATURES

UHF DTV FILTERS

UHF 2.5 kW Digital TV bandpass filter DVB/ATSC applications 8 Pole / 150 mm elliptical response tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

470 ÷ 862 MHz 2.5 kW DTV (3.75 kW ATV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 2.5 kW DTV 23.5 kg

676

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS DD EE

2 x 1-5/8” Unfl 2 x 3-1/8” Unfl * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 8 MHz Mask ≤ 0.55 dB at C.F. ≤ 2 dB at C.F. ± 3.8 MHz ≥ 12 dB at C.F. ± 4.2 MHz ≥ 30 dB at C.F. ± 6 MHz ≥ 55 dB at C.F. ± 12 MHz ≥ 26 dB ≤ 450 ns (Typical)

ATSC 6 MHz Mask ≤ 0.70 dB at C.F. ≤ 2.85 dB at C.F. ±2.85 MHz ≥ 14 dB at C.F. ±3.15 MHz ≥ 30 dB at C.F. ±4.5 MHz ≥ 50 dB at C.F. ±9 MHz ≥ 26 dB ≤ 450 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

45

MAX 485

ELECTRICAL DATA

301


CTV/U/DVB8-5 UHF DTV BANDPASS FILTER

FEATURES UHF 5 kW Digital TV bandpass filter DVB/ATSC applications 8 Pole / 200 mm elliptical response tunable within the whole UHF range temperature compensated SMA output monitor probe (optional)

UHF DTV FILETRS

470 ÷ 862 MHz 5 kW DTV (7.5 kW ATV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 25K at 5 kW DTV 55 kg

952

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS DD EE

2 x 1-5/8” Unfl 2 x 3-1/8” Unfl * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 8 MHz Mask ≤ 0.50 dB at C.F. ≤ 1.6 dB at C.F. ± 3.8 MHz ≥ 12 dB at C.F. ± 4.2 MHz ≥ 30 dB at C.F. ± 6 MHz ≥ 55 dB at C.F. ± 12 MHz ≥ 26 dB ≤ 450 ns (Typical)

ATSC 6 MHz Mask ≤ 0.55 dB at C.F. ≤ 2.15 dB at C.F. ±2.85 MHz ≥ 14 dB at C.F. ±3.15 MHz ≥ 30 dB at C.F. ±4.5 MHz ≥ 50 dB at C.F. ±9 MHz ≥ 26 dB ≤ 450 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

46

MAX 485

ELECTRICAL DATA

418


CTV/U/DVB8-10/LC UHF DTV BANDPASS FILTER

FEATURES

UHF DTV FILTERS

UHF 10 kW Digital TV bandpass filter DVB/ATSC applications 8 Pole / 200 mm elliptical response tunable within the whole UHF range temperature compensated SMA output monitor probe (optional) liquid cooled

470 ÷ 862 MHz 10 kW DTV (15 kW ATV) 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 10 kW DTV 57 kg

952

SPECIFICATIONS FREQUENCY RANGE MAX INPUT POWER * BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS DD EE

2 x 1-5/8” Unfl 2 x 3-1/8” Unfl * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY

RETURN LOSS GROUP DELAY VARIATION

DVB 8 MHz Mask ≤ 0.50 dB at C.F. ≤ 1.6 dB at C.F. ± 3.8 MHz ≥ 12 dB at C.F. ± 4.2 MHz ≥ 30 dB at C.F. ± 6 MHz ≥ 55 dB at C.F. ± 12 MHz ≥ 26 dB ≤ 450 ns (Typical)

ATSC 6 MHz Mask ≤ 0.55 dB at C.F. ≤ 2.15 dB at C.F. ±2.85 MHz ≥ 14 dB at C.F. ±3.15 MHz ≥ 30 dB at C.F. ±4.5 MHz ≥ 50 dB at C.F. ±9 MHz ≥ 26 dB ≤ 450 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

47

MAX 485

ELECTRICAL DATA

418



VHF BIII Combiners

51

UC/V/DVB-T/LB6-5

52

UC/V/DVB-T/LB6-10

53

UC/V/DVB-T/LB6-20

54

UC/V/DVB-T/LB8-10

55

VHF BIII COMBINERS

Functioning principles of VHF combiners

SpeciďŹ cations are subject to change without prior notice

49



Functioning principles of VHF combiners

FUNCTIONING PRINCIPLES OF VHF DIRECTIONAL FILTER TYPE COMBINERS

2

Tx 1 1 A1 (f1) 3

BP 1

R

Antenna

(f1)

2

Tx 2 1 A2 (f2)

4

SCHEMATIC DIAGRAM

(f1)

4

f1 + f2

3

BP 2

Specifications are subject to change without prior notice

51

VHF BIII COMBINERS

The signal generated by a transmitter on a specific VHF channel, say ch1, is delivered to port 1 (Narrow Band input) of coupler A1 (3 dB coupler) which splits the power in two halves onto ports 2 and 3, whilst virtually no power goes to port 4 which is the absorber load port. The two half power signals flow through the band pass filters BP1 and BP2, both tuned on frequency of ch1, and reach ports 2 and 3 of 3dB coupler A2. Due to the phase difference between the two half signals, they get summed up on A2 (3 dB coupler), so that the whole ch1 transmitter power (less NB input loss) gets to port 4 of A2, which actually is the combiner output. Similarly, the signal from another transmitter (ch2), is delivered to port 1 of coupler A2 (3 dB coupler). The signal is split in two by the 3dB coupler and flows towards the band pass filters. Being these tuned on frequency of ch1, ch2 signal is rejected by the band pass filters, and as per the previous case, the phase difference between ports 2 and 3 of the 3 dB coupler allows the summed up half power ch2 signals to get to the combiner output (port 4). By doing so, both transmitter signals are summed up at the output and kept separated (isolation) by means of the 3 dB coupler directivity as well as by the selectivity of the band pass filters. Different stages of selectivity and isolation of SIRA’s VHF filters and 3dB couplers make SIRA’s combiner modules suitable for ATV and DTV uses, in both eventualities of critical and non-critical mask applications. The high quality standard applied to each single component forming a part of SIRA’s Combiners, along with the regular testing measurements that each SIRA product subdues before leaving the factory, guarantees the best return loss characteristics, and makes the combiners suitable even for VSWR-critical applications.


UC/V/DVB-T/LB6-5 VHF BIII DTV COMBINER

FEATURES VHF BIII DTV double bridge channel combiner 5 kW NB Input power DVB/ATSC applications 6 Pole elliptical response / 120 mm suitable for adjacent channel combination

174 ÷ 240 MHz 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 5 kW DTV (NB) 90 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 5kW (7.5kW) 10kW (15kW) 10kW (15kW) * referred to DVB-T 7 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C t

A=Nf

B=7/16f

C= 7/8”unfl

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

G=RL-120

DVB 7 MHz Mask NB INSERTION LOSS (Typical)** ≤ 0.30 dB at C.F. ≤ 0.80 dB at C.F. ±3.325 MHz WB INSERTION LOSS ≤ 0.05 dB SELECTIVITY ≥ 4 dB at C.F.±3.675 MHz ≥ 16 dB at C.F.±5.25 MHz ≥ 42 dB at C.F.±10.5 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 400 ns (Typical)

ATSC 6 MHz Mask ≤ 0.40 dB at C.F. ≤ 0.82 dB at C.F. ±2.7 MHz ≤ 0.05 dB ≥ 3 dB at C.F.±3.5 MHz ≥ 29 dB at C.F.±6 MHz ≥ 38 dB at C.F.±9 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 350 ns (Typical)

880

ELECTRICAL DATA

WB INPUT

NB INPUT

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

52

OUTPUT

300

VHF BIII COMBINERS

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT D D D

1460


UC/V/DVB-T/LB6-10 VHF BIII DTV COMBINER

FEATURES VHF BIII DTV double bridge channel combiner 10 kW NB Input power DVB/ATSC applications 6 Pole elliptical response / 150 mm suitable for adjacent channel combination

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT E E E D E E

A=Nf

B=7/16f

C= 7/8”unfl

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

G=RL-120 1090

t

VHF BIII COMBINERS

174 ÷ 240 MHz 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 10 kW DTV (NB) 110 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 10kW (15kW) 20kW (30kW) 20kW (30kW) 10kW (15kW) 20kW (30kW) 20kW (30kW) * referred to DVB-T 7 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA ATSC 6 MHz Mask ≤ 0.35 dB at C.F. ≤ 0.60 dB at C.F. ±2.7 MHz ≤ 0.05 dB ≥ 3 dB at C.F.±3.5 MHz ≥ 29 dB at C.F.±6 MHz ≥ 38 dB at C.F.±9 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 350 ns (Typical)

WB INPUT

NB INPUT

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

53

OUTPUT

365

DVB 7 MHz Mask NB INSERTION LOSS (Typical)** ≤ 0.29 dB at C.F. ≤ 0.75 dB at C.F. ±3.325 MHz WB INSERTION LOSS ≤ 0.05 dB SELECTIVITY ≥ 4 dB at C.F.±3.675 MHz ≥ 16 dB at C.F.±5.25 MHz ≥ 42 dB at C.F.±10.5 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 300 ns (Typical)

1610


UC/V/DVB-T/LB6-20 VHF BIII DTV COMBINER

FEATURES VHF BIII DTV double bridge channel combiner 20 kW NB Input power DVB/ATSC applications 6 Pole elliptical response / 200 mm suitable for adjacent channel combination

174 ÷ 240 MHz 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 20 kW DTV (NB) 175 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 20kW (30kW) 30kW (45kW) 30kW (45kW) * referred to DVB-T 7 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C A=Nf

B=7/16f

C= 7/8”unfl

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

G=RL-120

1000

t

ELECTRICAL DATA DVB 7 MHz Mask NB INSERTION LOSS (Typical)** ≤ 0.23 dB at C.F. ≤ 0.54 dB at C.F. ±3.325 MHz WB INSERTION LOSS ≤ 0.05 dB SELECTIVITY ≥ 4 dB at C.F.±3.675 MHz ≥ 16 dB at C.F.±5.25 MHz ≥ 42 dB at C.F.±10.5 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 300 ns (Typical)

ATSC 6 MHz Mask ≤ 0.28 dB at C.F. ≤ 0.44 dB at C.F. ±2.7 MHz ≤ 0.05 dB ≥ 3 dB at C.F.±3.5 MHz ≥ 29 dB at C.F.±6 MHz ≥ 38 dB at C.F.±9 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 350 ns (Typical)

WB INPUT

NB INPUT

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

54

OUTPUT

485

VHF BIII COMBINERS

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT E E E

2020


UC/V/DVB-T/LB8-10 VHF BIII DTV COMBINER

FEATURES VHF BIII DTV double bridge channel combiner 10 kW NB Input power DVB/ATSC applications 8 Pole elliptical response / 150 mm suitable for adjacent channel combination

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT D E E

A=Nf

B=7/16f

C= 7/8”unfl

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

G=RL-120

1090

t

VHF BIII COMBINERS

174 ÷ 240 MHz 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 10 kW DTV (NB) 136 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 10kW (15kW) 20kW (30kW) 20kW (30kW) * referred to DVB-T 7 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA DVB 7 MHz C. Mask NB INSERTION LOSS (Typical)** ≤ 0.35 dB at C.F. ≤ 0.95 dB at C.F. ±3.325 MHz WB INSERTION LOSS ≤ 0.05 dB SELECTIVITY ≥ 14 dB at C.F.±3.675 MHz ≥ 26 dB at C.F.±5.25 MHz ≥ 55 dB at C.F.±10.5 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 550 ns (Typical)

WB INPUT

365

OUTPUT

NB INPUT 1910

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

55



VHF DAB Combiners

59

UC/V/DAB/LB6-2.4

60

UC/V/DAB/LB6-5

61

VHF DAB COMBINERS

UC/V/DAB/LB6-1.2

SpeciямБcations are subject to change without prior notice

57



UC/V/DAB/LB6-1.2 VHF BIII DAB COMBINER

FEATURES VHF BIII DAB double bridge channel combiner 1.2 kW NB Input power DAB/T-DMB applications 6 Pole elliptical response / 120 mm suitable for adjacent block combination

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT B B B C C C

A=Nf

B=7/16f

C= 7/8”unfl

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

G=RL-120

875

t

ELECTRICAL DATA DAB C.M.2 ≤ 1.10 dB at C.F. ≤ 2.35 dB at C.F. ±0.77 MHz ≤ 0.05 dB ≥ 10 dB at C.F. ± 0.97 MHz ≥ 40 dB at C.F. ± 1.75 MHz ≥ 40 dB at C.F. ± 2.2 MHz ≥ 40 dB at C.F. ± 3 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 800 ns (Typical)

WB INPUT

NB INPUT

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

59

OUTPUT

300

DAB C.M.1 NB INSERTION LOSS (Typical)** ≤ 1.10 dB at C.F. ≤ 2.55 dB at C.F. ±0.77 MHz WB INSERTION LOSS ≤ 0.05 dB SELECTIVITY ≥ 15 dB at C.F. ± 0.97 MHz ≥ 45 dB at C.F. ± 1.75 MHz ≥ 45 dB at C.F. ± 2.2 MHz ≥ 45 dB at C.F. ± 3 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 950 ns (Typical)

1350

VHF DAB COMBINERS

174 ÷ 240 MHz 1.54 MHz ≤ 1 kHz/K -10 to + 50°C 30K at 1.2 kW (NB) 85 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 1.2kW (1.8kW) 3kW (4.5kW) 3kW (4.5kW) 1.2kW (1.8kW) 3kW (4.5kW) 3kW (4.5kW) * referred to DAB block 12D, C.M.1 standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C


UC/V/DAB/LB6-2.4 VHF BIII DAB COMBINER

FEATURES VHF BIII DAB double bridge channel combiner 2.4 kW NB Input power DAB/T-DMB applications 6 Pole elliptical response / 150 mm suitable for adjacent block combination

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT D D D

174 ÷ 240 MHz 1.54 MHz ≤ 1 kHz/K -10 to + 50°C 30K at 2.4 kW (NB) 110 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 2.4kW (3.6kW) 10kW (15kW) 10kW (15kW) * referred to DAB block 12D, C.M.1 standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C t

B=7/16f

C= 7/8”unfl

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

G=RL-120

DAB C.M.1 NB INSERTION LOSS (Typical)** ≤ 0.90 dB at C.F. ≤ 2.05 dB at C.F. ±0.77 MHz WB INSERTION LOSS ≤ 0.05 dB SELECTIVITY ≥ 15 dB at C.F. ± 0.97 MHz ≥ 45 dB at C.F. ± 1.75 MHz ≥ 45 dB at C.F. ± 2.2 MHz ≥ 45 dB at C.F. ± 3 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 950 ns (Typical)

DAB C.M.2 ≤ 0.90 dB at C.F. ≤ 1.95 dB at C.F. ±0.77 MHz ≤ 0.05 dB ≥ 10 dB at C.F. ± 0.97 MHz ≥ 40 dB at C.F. ± 1.75 MHz ≥ 40 dB at C.F. ± 2.2 MHz ≥ 40 dB at C.F. ± 3 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 800 ns (Typical)

875

ELECTRICAL DATA

WB INPUT

NB INPUT

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

60

OUTPUT

365

VHF DAB COMBINERS

A=Nf

1610


UC/V/DAB/LB6-5 VHF BIII DAB COMBINER

FEATURES VHF BIII DAB double bridge channel combiner 5 kW NB Input power DAB/T-DMB applications 6 Pole elliptical response / 200 mm suitable for adjacent block combination

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT D E E

174 ÷ 240 MHz 1.54 MHz ≤ 1 kHz/K -10 to + 50°C 30K at 5 kW (NB) 165 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 5kW (7.5kW) 20kW (30kW) 20kW (30kW) * referred to DAB block 12D, C.M.1 standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C A=Nf

B=7/16f

C= 7/8”unfl

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

G=RL-120

VHF DAB COMBINERS

t

DAB C.M.2 ≤ 0.65 dB at C.F. ≤ 1.55 dB at C.F. ±0.77 MHz ≤ 0.05 dB ≥ 10 dB at C.F. ± 0.97 MHz ≥ 40 dB at C.F. ± 1.75 MHz ≥ 40 dB at C.F. ± 2.2 MHz ≥ 40 dB at C.F. ± 3 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 800 ns (Typical)

WB INPUT

NB INPUT

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

61

OUTPUT

485

DAB C.M.1 NB INSERTION LOSS (Typical)** ≤ 0.65 dB at C.F. ≤ 1.55 dB at C.F. ±0.77 MHz WB INSERTION LOSS ≤ 0.05 dB SELECTIVITY ≥ 15 dB at C.F. ± 0.97 MHz ≥ 45 dB at C.F. ± 1.75 MHz ≥ 45 dB at C.F. ± 2.2 MHz ≥ 45 dB at C.F. ± 3 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 950 ns (Typical)

995

ELECTRICAL DATA

1960



Functioning principles of UHF combiners

65

UC/U/M3-015/2

66

UC/U/M3-015/3

67

UC/U/M3-015/4

68

UC/U/M3-015/5

69

UC/U/M3-015/6

70

UC/U/M3-030/5

71

UC/U/M3-030/6

72

UC/U/LB3-06

73

UC/U/LB3-1.5

74

UC/U/LB32-1.5

75

UC/U/LB4-06

76

UC/U/LB4-1.5

77

UC/U/LB4-3

78

UC/U/LB4-6/M

79

UC/U/LB4-15/M

80

UC/U/LB4-30/M

81

SpeciďŹ cations are subject to change without prior notice

63

UHF ATV COMBINERS

UHF ATV Combiners



Functioning principles of UHF combiners

FUNCTIONING PRINCIPLES OF UHF DIRECTIONAL FILTER TYPE COMBINERS The signal generated by a transmitter on a specific UHF channel, say ch1, is delivered to port 1 (Narrow Band input) of coupler A1 (3 dB coupler) which splits the power in two halves onto ports 2 and 3, whilst virtually no power goes to port 4 which is the absorber load port. The two half power signals flow through the band pass filters BP1 and BP2, both tuned on frequency of ch1, and reach ports 2 and 3 of 3dB coupler A2. Due to the phase difference between the two half signals, they get summed up on A2 (3 dB coupler), so that the whole ch1 transmitter power (less NB input loss) gets to port 4 of A2, which actually is the combiner output. Similarly, the signal from another transmitter (ch2), is delivered to port 1 of coupler A2 (3 dB coupler). The signal is split in two by the 3dB coupler and flows towards the band pass filters. Being these tuned on frequency of ch1, ch2 signal is rejected by the band pass filters, and as per the previous case, the phase difference between ports 2 and 3 of the 3 dB coupler allows the summed up half power ch2 signals to get to the combiner output (port 4). By doing so, both transmitter signals are summed up at the output and kept separated (isolation) by means of the 3 dB coupler directivity as well as by the selectivity of the band pass filters. Different stages of selectivity and isolation of SIRA’s UHF filters and 3dB couplers make SIRA’s combiner modules suitable for ATV and DTV uses, in both eventualities of critical and non-critical mask applications. The high quality standard applied to each single component forming a part of SIRA’s Combiners, along with the regular testing measurements that each SIRA product subdues before leaving the factory, guarantees the best return loss characteristics, and makes the combiners suitable even for VSWR-critical applications.

2

Tx 1 1 A1 (f1) 3

BP 1

R

Antenna

(f1)

2

Tx 2 1 A2 (f2)

4

SCHEMATIC DIAGRAM

(f1)

4

f1 + f2

3

BP 2

The Star Type Combiner basically consists of parallel connecting several transmitters to a single antenna system through suitable bandpass filters, each one tuned on the transmitter frequency to which it is connected. The parallel connection is obtained by means of coaxial lines of critical lenght. The RF power generated by TX1 (ch1) passes through filter BP1 to the star centre C to which the antenna is connected. In order to transfer to the antenna the total power from TX1,the short circuit of TX2 at TX1 frequency , must be converted to an open circuit at the star junction centre by means of L2. The same applies for transferring power from transmitters TX2 and the related conversion lines L1, L2.

SCHEMATIC DIAGRAM ANTENNA

TX1 (f1)

65

L1

f1 + f2

L2

TX2 (f2)

?

?

BP1

Specifications are subject to change without prior notice

UHF ATV COMBINERS

FUNCTIONING PRINCIPLES OF UHF STAR TYPE MODULAR COMBINER

BP2


UC/U/M3-015/2 UHF ATV COMBINER

FEATURES UHF Modular Multiplexer 150 W channel input power (ATV) 50 W channel input power (DTV) 3 Pole / 40 mm 2 Inputs Low Loss Very compact and lightweight

SPECIFICATIONS FREQUENCY RANGE MAX CHANNEL INPUT POWER * MAX OUTPUT POWER BANDWITH MIN DISTANCE BETWEEN CH.*** TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS inputs / output

132

470 ÷ 862 MHz 150 W ATV (50 W DTV) 300 W ATV (100 W DTV) 6 to 8 MHz 2 guard channels (CCIR G) 3 guard channels (FCC M, UHF B) ≤ 15 kHz/K -10 to + 50°C 30K at 150 W ATV 1.5 Kg

2 x NF / NF * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C *** 1 guard channel available on request

INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS DE-COUPLING GROUP DELAY VARIATION

CCIR G Standard ≤ 0.7 dB at C.F. ≥ 3 dB at V.C. -5.5/+11 MHz ≥ 10 dB at V.C. -11/+16.5 MHz ≥ 21 dB ≥ 20 dB (2 guard channels) ≥ 30 dB (3 or more guard channels) ≤ 25 ns (Typical)

FCC M Standard ≤ 0.7 dB at C.F. ≥ 6 dB at V.C. -9/+13.5 MHz ≥ 21 dB ≥ 20 dB (3 guard channels) ≥ 30 dB (4 or more guard channels) ≤ 25 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

66

122

UHF ATV COMBINERS

ELECTRICAL DATA

81


UC/U/M3-015/3 UHF ATV COMBINER

FEATURES UHF Modular Multiplexer 150 W channel input power (ATV) 50 W channel input power (DTV) 3 Pole / 40 mm 3 Inputs Low Loss Very compact and lightweight

SPECIFICATIONS FREQUENCY RANGE MAX CHANNEL INPUT POWER * MAX OUTPUT POWER BANDWITH MIN DISTANCE BETWEEN CH.*** TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS inputs / output

132

470 ÷ 862 MHz 150 W ATV (50 W DTV) 400 W ATV (150 W DTV) 6 to 8 MHz 2 guard channels (CCIR G) 3 guard channels (FCC M, UHF B) ≤ 15 kHz/K -10 to + 50°C 30 K at 150 W ATV 2 Kg

3 x NF / NF * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C UHF ATV COMBINERS

*** 1 guard channel available on request

ELECTRICAL DATA

RETURN LOSS DE-COUPLING GROUP DELAY VARIATION

CCIR G Standard ≤ 0.7 dB at C.F. ≥ 3 dB at V.C. -5.5/+11 MHz ≥ 10 dB at V.C. -11/+16.5 MHz ≥ 21 dB ≥ 20 dB (2 guard channels) ≥ 30 dB (3 or more guard channels) ≤ 25 ns (Typical)

FCC M Standard ≤ 0.7 dB at C.F. ≥ 6 dB at V.C. -9/+13.5 MHz ≥ 21 dB ≥ 20 dB (3 guard channels) ≥ 30 dB (4 or more guard channels) ≤ 25 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

67

122

INSERTION LOSS (Typical)** SELECTIVITY

121


UC/U/M3-015/4 UHF ATV COMBINER

FEATURES UHF modular multiplexer 150 W channel input power (ATV) 50 W channel input power (DTV) 3 Pole / 40 mm 4 Inputs Low Loss Very compact and lightweight

SPECIFICATIONS FREQUENCY RANGE MAX CHANNEL INPUT POWER * MAX OUTPUT POWER BANDWITH MIN DISTANCE BETWEEN CH.*** TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS inputs / output

132

470 ÷ 862 MHz 150 W ATV (50 W DTV) 400 W ATV (200 W DTV) 6 to 8 MHz 2 guard channels (CCIR G) 3 guard channels (FCC M, UHF B) ≤ 15 kHz/K -10 to + 50°C 30K at 150 W ATV 2.5 Kg

4 x NF / NF * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C *** 1 guard channel available on request

INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS DE-COUPLING GROUP DELAY VARIATION

CCIR G Standard ≤ 0.7 dB at C.F. ≥ 3 dB at V.C. -5.5/+11 MHz ≥ 10 dB at V.C. -11/+16.5 MHz ≥ 21 dB ≥ 20 dB (2 guard channels) ≥ 30 dB (3 or more guard channels) ≤ 25 ns (Typical)

FCC M Standard ≤ 0.7 dB at C.F. ≥ 6 dB at V.C. -9/+13.5 MHz ≥ 21 dB ≥ 20 dB (3 guard channels) ≥ 30 dB (4 or more guard channels) ≤ 25 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

68

122

UHF ATV COMBINERS

ELECTRICAL DATA


UC/U/M3-015/5 UHF ATV COMBINER

FEATURES UHF modular multiplexer 150 W channel input power (ATV) 50 W channel input power (DTV) 3 Pole / 40 mm 5 Inputs Low Loss Very compact and lightweight

SPECIFICATIONS FREQUENCY RANGE MAX CHANNEL INPUT POWER * MAX OUTPUT POWER BANDWITH MIN DISTANCE BETWEEN CH.*** TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS inputs / output

132

470 ÷ 862 MHz 150 W ATV (50 W DTV) 400 W ATV (200 W DTV) 6 to 8 MHz 2 guard channels (CCIR G) 3 guard channels (FCC M, UHF B) ≤ 15 kHz/K -10 to + 50°C 30K at 150 W ATV 3.5 Kg

5 x NF / NF * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS DE-COUPLING GROUP DELAY VARIATION

CCIR G Standard ≤ 0.7 dB at C.F. ≥ 3 dB at V.C. -5.5/+11 MHz ≥ 10 dB at V.C. -11/+16.5 MHz ≥ 21 dB ≥ 20 dB (2 guard channels) ≥ 30 dB (3 or more guard channels) ≤ 25 ns (Typical)

FCC M Standard ≤ 0.7 dB at C.F. ≥ 6 dB at V.C. -9/+13.5 MHz ≥ 21 dB ≥ 20 dB (3 guard channels) ≥ 30 dB (4 or more guard channels) ≤ 25 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

69

121

UHF ATV COMBINERS

243

*** 1 guard channel available on request


UC/U/M3-015/6 UHF ATV COMBINER

FEATURES UHF modular multiplexer 150 W channel input power (ATV) 50 W channel input power (DTV) 3 Pole / 40 mm 6 Inputs Low Loss Very compact and lightweight

TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS inputs / output

470 ÷ 862 MHz 150 W ATV (50 W DTV) 400 W ATV (200 W DTV) 6 to 8 MHz 2 guard channels (CCIR G) 3 guard channels (FCC M, UHF B) ≤ 15 kHz/K -10 to + 50°C 30K at 150 W ATV 3.7 Kg

132

SPECIFICATIONS FREQUENCY RANGE MAX CHANNEL INPUT POWER * MAX OUTPUT POWER BANDWITH MIN DISTANCE BETWEEN CH.***

6 x NF / NF

UHF ATV COMBINERS

243

* referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C *** 1 guard channel available on request

ELECTRICAL DATA INSERTION LOSS (typical)** SELECTIVITY RETURN LOSS DE-COUPLING GROUP DELAY VARIATION

CCIR G Standard ≤ 0.7 dB at C.F. ≥ 3 dB at V.C. -5.5/+11 MHz ≥ 10 dB at V.C. -11/+16.5 MHz ≥ 21 dB ≥ 20 dB (2 guard channels) ≥ 30 dB (3 or more guard channels) ≤ 25 ns (Typical)

FCC M Standard ≤ 0.7 dB at C.F. ≥ 6 dB at V.C. -9/+13.5 MHz ≥ 21 dB ≥ 20 dB (3 guard channels) ≥ 30 dB (4 or more guard channels) ≤ 25 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

70

121


UC/U/M3-030/5 UHF ATV COMBINER

FEATURES UHF modular multiplexer 300 W channel input power (ATV) 150 W channel input power (DTV) 3 Pole / 50 mm 5 Inputs Low Loss Very compact and lightweight

TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS inputs / output

470 ÷ 862 MHz 300 W ATV (150 W DTV) 800 W ATV (500 W DTV) 6 to 8 MHz 2 guard channels (CCIR G) 3 guard channels (FCC M, UHF B) ≤ 15 kHz/K -10 to + 50°C 30K at 300 W ATV 4.2 Kg

157

SPECIFICATIONS FREQUENCY RANGE MAX CHANNEL INPUT POWER * MAX OUTPUT POWER BANDWITH MIN DISTANCE BETWEEN CH.***

5 x NF / 7/16 F

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS DE-COUPLING GROUP DELAY VARIATION

CCIR G Standard ≤ 0.5 dB at C.F. ≥ 3 dB at V.C. -5.5/+11 MHz ≥ 10 dB at V.C. -11/+16.5 MHz ≥ 21 dB ≥ 20 dB (2 guard channels) ≥ 30 dB (3 or more guard channels) ≤ 25 ns (Typical)

FCC M Standard ≤ 0.5 dB at C.F. ≥ 6 dB at V.C. -9/+13.5 MHz ≥ 21 dB ≥ 20 dB (3 guard channels) ≥ 30 dB (4 or more guard channels) ≤ 25 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

71

169

UHF ATV COMBINERS

329

* referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C *** 1 guard channel available on request


UC/U/M3-030/6 UHF ATV COMBINER

FEATURES UHF modular multiplexer 300 W channel input power (ATV) 150 W channel input power (DTV) 3 Pole / 50 mm 6 Inputs Low Loss Very compact and lightweight

SPECIFICATIONS FREQUENCY RANGE MAX CHANNEL INPUT POWER * MAX OUTPUT POWER BANDWITH MIN DISTANCE BETWEEN CH.*** TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS inputs / output

157

470 ÷ 862 MHz 300 W ATV (150 W DTV) 800 W ATV (500 W DTV) 6 to 8 MHz 2 guard channels (CCIR G) 3 guard channels (FCC M, UHF B) ≤ 15 kHz/K -10 to + 50°C 30K at 300 W ATV 4.4 Kg

6 x NF / 7/16 F * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C UHF ATV COMBINERS

329

*** 1 guard channel available on request

ELECTRICAL DATA INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS DE-COUPLING GROUP DELAY VARIATION

CCIR G Standard ≤ 0.5 dB at C.F. ≥ 3 dB at V.C. -5.5/+11 MHz ≥ 10 dB at V.C. -11/+16.5 MHz ≥ 21 dB ≥ 20 dB (2 guard channel) ≥ 30 dB (3 or more guard channel) ≤ 25 ns (Typical)

FCC M Standard ≤ 0.5 dB at C.F. ≥ 6 dB at V.C. -9/+13.5 MHz ≥ 21 dB ≥ 20 dB (3 guard channel) ≥ 30 dB (4 or more guard channel) ≤ 25 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

72

169


UC/U/LB3-06 UHF ATV COMBINER

FEATURES UHF double bridge channel combiner 600 W ATV NB input power 3 Pole / 40 mm

SPECIFICATIONS FREQUENCY RANGE BANDWITH MIN. DISTANCE BETWEEN CH. TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT B B B A A A B=7/16f

C= 7/8”unfl or EIA D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

G=RL-120

WB INPUT

ELECTRICAL DATA CCIR G Standard NB INSERTION LOSS (Typical)** ≤ 0.65 dB at C.F. WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 3 dB at V.C. -5.5/+11 MHz ≥ 12 dB at V.C. -11/+16.5 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB DE-COUPLING ≥ 30 dB NB Group Delay Variation ≤ 25 ns (Typical)

FCC M Standard ≤ 0.75 dB at C.F. ≤ 0.08 dB ≥ 3 dB at V.C. -4.5/+9 MHz ≥ 12 dB at V.C. -9/+13.5 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 25 ns (Typical)

NB INPUT

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

73

OUTPUT

175

UHF ATV COMBINERS

A=Nf

168

t

294

470 ÷ 862 MHz 6 to 8 MHz 1 guard channel ≤ 15 kHz/K -10 to + 50°C 40K at 600 W ATV (NB) 4 Kg INPUTS / OUTPUT ATV (DTV) POWER * NB WB OUT 600W (200W) 600W (400W) 600W (400W) 300W (200W) 300W (200W) 300W (200W) * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C


UC/U/LB3-1.5 UHF ATV COMBINER

FEATURES UHF double bridge channel combiner 1.5 kW ATV NB input power 3 Pole / 50 mm

SPECIFICATIONS FREQUENCY RANGE BANDWITH MIN. DISTANCE BETWEEN CH. TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT C C C B B B

t

A=Nf

B=7/16f

C= 7/8”EIA or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

367

470 ÷ 862 MHz 6 to 8 MHz 1 guard channel ≤ 15 kHz/K -10 to + 50°C 35K at 1.5 kW ATV (NB) 6.8 Kg INPUTS / OUTPUT ATV (DTV) POWER * NB WB OUT 1.5kW (500W) 3kW (2kW) 3kW (2kW) 1.5kW (500W) 1.5kW (1kW) 1.5kW (1kW) * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120

WB INPUT

OUTPUT

CCIR G Standard NB INSERTION LOSS (Typical)** ≤ 0.50 dB at C.F. WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 3 dB at V.C. -5.5/+11 MHz ≥ 12 dB at V.C. -11/+16.5 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB DE-COUPLING ≥ 30 dB NB Group Delay Variation ≤ 25 ns (Typical)

FCC M Standard ≤ 0.60 dB at C.F. ≤ 0.08 dB ≥ 3 dB at V.C. -4.5/+9 MHz ≥ 12 dB at V.C. -9/+13.5 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 25 ns (Typical)

258

UHF ATV COMBINERS

ELECTRICAL DATA

NB INPUT

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

74

191


UC/U/LB32-1.5 UHF ATV COMBINER

FEATURES UHF double bridge channel combiner 1.5 kW ATV NB input power 3 Pole + 2 notch / 50 mm

SPECIFICATIONS FREQUENCY RANGE BANDWITH MIN. DISTANCE BETWEEN CH. TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT C C C B B B

t

A=Nf

B=7/16f

C= 7/8”unfl

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

360

470 ÷ 862 MHz 6 to 8 MHz 1 guard channel ≤ 15 kHz/K -10 to + 50°C 35K at 1.5 kW ATV (NB) 7.4 Kg INPUTS / OUTPUT ATV (DTV) POWER * NB WB OUT 1.5kW (500W) 3kW (2kW) 3kW (2kW) 1.5kW (500W) 3kW (2kW) 3kW (2kW) * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120 WB INPUT

UHF ATV COMBINERS

OUTPUT

CCIR G Standard NB INSERTION LOSS (Typical)** ≤ 0.50 dB at C.F. WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 30 dB at V.C. -5.5/+11 MHz ≥ 13 dB at V.C. -11/+16.5 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB DE-COUPLING ≥ 30 dB NB Group Delay Variation ≤ 25 ns (Typical)

FCC M Standard ≤ 0.60 dB at C.F. ≤ 0.08 dB ≥ 30 dB at V.C. -4.5/+9 MHz ≥ 13 dB at V.C. -9/+13.5 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 25 ns (Typical)

312

ELECTRICAL DATA

NB INPUT

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

75

191


UC/U/LB4-06 UHF ATV COMBINER

FEATURES UHF double bridge channel combiner 600 W ATV NB input power 4 Pole / 40 mm

SPECIFICATIONS FREQUENCY RANGE BANDWITH MIN. DISTANCE BETWEEN CH. TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT B B B A A A

t

A=Nf

B=7/16f

C= 7/8”unfl or EIA D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

293

470 ÷ 862 MHz 6 to 8 MHz 1 guard channel ≤ 15 kHz/K -10 to + 50°C 40K at 600 W ATV (NB) 4.5 Kg INPUTS / OUTPUT ATV (DTV) POWER * NB WB OUT 600W (200W) 600W (400W) 600W (400W) 300W (200W) 300W (200W) 300W (200W) * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120 WB INPUT

OUTPUT

CCIR G Standard NB INSERTION LOSS (Typical)** ≤ 0.85 dB at C.F. WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 8 dB at V.C. -5.5/+11 MHz ≥ 25 dB at V.C. -11/+16.5 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB DE-COUPLING ≥ 30 dB NB Group Delay Variation ≤ 35 ns (Typical)

FCC M Standard ≤ 0.99 dB at C.F. ≤ 0.08 dB ≥ 8 dB at V.C. -4.5/+9 MHz ≥ 25 dB at V.C. -9/+13.5 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 35 ns (Typical)

211

UHF ATV COMBINERS

ELECTRICAL DATA

NB INPUT

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

76

175


UC/U/LB4-1.5 UHF ATV COMBINER

FEATURES UHF double bridge channel combiner 1.5 kW ATV NB input power 4 Pole / 50 mm

SPECIFICATIONS FREQUENCY RANGE BANDWITH MIN. DISTANCE BETWEEN CH. TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT C C C B B B

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

G=RL-120

WB INPUT

OUTPUT

CCIR G Standard NB INSERTION LOSS (Typical)** ≤ 0.75 dB at C.F. WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 8 dB at V.C. -5.5/+11 MHz ≥ 25 dB at V.C. -11/+16.5 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB DE-COUPLING ≥ 30 dB NB Group Delay Variation ≤ 35 ns (Typical)

FCC M Standard ≤ 0.90 dB at C.F. ≤ 0.08 dB ≥ 8 dB at V.C. -4.5/+9 MHz ≥ 25 dB at V.C. -9/+13.5 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 35 ns (Typical)

258

ELECTRICAL DATA

NB INPUT

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

77

191

UHF ATV COMBINERS

t

367

470 ÷ 862 MHz 6 to 8 MHz 1 guard channel ≤ 15 kHz/K -10 to + 50°C 30K at 1.5 kW ATV (NB) 7.8 Kg INPUTS / OUTPUT ATV (DTV) POWER * NB WB OUT 1.5kW (500W) 3kW (2kW) 3kW (2kW) 1.5kW (500W) 1.5kW (1kW) 1.5kW (1kW) * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C


UC/U/LB4-3 UHF ATV COMBINER

FEATURES UHF double bridge channel combiner 3 kW ATV NB input power 4 Pole elliptical response / 85 mm

SPECIFICATIONS FREQUENCY RANGE BANDWITH MIN. DISTANCE BETWEEN CH. TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT D D D C D D

t

A=Nf

B=7/16f

C= 7/8”unfl or EIA D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

560

470 ÷ 862 MHz 6 to 8 MHz 1 guard channel ≤ 2 kHz/K -10 to + 50°C 35K at 3 kW ATV (NB) 18 Kg INPUTS / OUTPUT ATV (DTV) POWER * NB WB OUT 3kW (1kW) 7.5kW (5kW) 7.5kW (5kW) 3kW (1kW) 7.5kW (5kW) 7.5kW (5kW) * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120

CCIR G Standard NB INSERTION LOSS (Typical)** ≤ 0.40 dB at C.F. ≤ 0.08 dB WB INSERTION LOSS ≥ 40 dB at V.C. -5.5/+11 MHz SELECTIVITY ≥ 24 dB at V.C. -11/+16.5 MHz NB ≥ 26 dB RETURN LOSS WB ≥ 26 dB on specified channel or WB ≥ 23 dB DE-COUPLING ≥ 30 dB ≤ 45 ns (Typical) NB Group Delay Variation

FCC M Standard ≤ 0.45 dB at C.F. ≤ 0.08 dB ≥ 40 dB at V.C. -4.5/+9 MHz ≥ 24 dB at V.C. -9/+13.5 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 45 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

78

WB INPUT

OUTPUT

250

UHF ATV COMBINERS

ELECTRICAL DATA

NB INPUT 480


UC/U/LB4-6/M UHF ATV COMBINER

FEATURES UHF double bridge channel combiner 6 kW ATV NB Input power 4 Pole elliptical response/ 120 mm multisection 3dB couplers

SPECIFICATIONS FREQUENCY RANGE BANDWITH MIN. DISTANCE BETWEEN CH. TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT D E E D D E D D D

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

G=RL-120

UHF ATV COMBINERS

t

600

470 ÷ 862 MHz 6 to 8 MHz 1 guard channel ≤ 2 kHz/K -10 to + 50°C 35K at 6 kW ATV (NB) 27 Kg INPUTS / OUTPUT ATV (DTV) POWER * NB WB OUT 6kW (2kW) 15kW (10kW) 15kW (10kW) 6kW (2kW) 7.5kW (5kW) 13.5kW (7kW) 6kW (2kW) 7.5kW (5kW) 7.5kW (5kW) * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA NB INSERTION LOSS (Typical)** ≤ 0.30 dB at C.F. WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 40 dB at V.C. -5.5/+11 MHz ≥ 24 dB at V.C. -11/+16.5 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB (Typical) DE-COUPLING ≥ 30 dB NB Group Delay Variation ≤ 45 ns (Typical)

≤ 0.35 dB at C.F. ≤ 0.08 dB ≥ 40 dB at V.C. -4.5/+9 MHz ≥ 24 dB at V.C. -9/+13.5 MHz NB ≥ 26 dB WB ≥ 26 dB (Typical) ≥ 30 dB ≤ 45 ns (Typical)

WB INPUT

NB INPUT

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

79

OUTPUT

280

FCC M Standard

CCIR G Standard

638


UC/U/LB4-15/M UHF ATV COMBINER

FEATURES UHF double bridge channel combiner 15 kW ATV NB Input power 4 Pole elliptical response/ 150 mm multisection 3dB couplers

SPECIFICATIONS FREQUENCY RANGE BANDWITH MIN. DISTANCE BETWEEN CH. TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT E E E D E E D D E

t

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

760

470 ÷ 862 MHz 6 to 8 MHz 1 guard channel ≤ 2 kHz/K -10 to + 50°C 45K at 15 kW ATV (NB) 70 Kg INPUTS / OUTPUT ATV (DTV) POWER * NB WB OUT 15kW (7.5kW) 20kW (15kW) 20kW (15kW) 7.5kW (5kW) 20kW (15kW) 20kW (15kW) 7.5kW (5kW) 7.5kW (5kW) 15kW (10kW) * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120

FCC M Standard

CCIR G Standard NB INSERTION LOSS (Typical)** ≤ 0.25 dB at C.F. WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 40 dB at V.C. -5.5/+11 MHz ≥ 24 dB at V.C. -11/+16.5 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB (Typical) DE-COUPLING ≥ 30 dB NB Group Delay Variation ≤ 45 ns (Typical)

≤ 0.30 dB at C.F. ≤ 0.08 dB ≥ 40 dB at V.C. -4.5/+9 MHz ≥ 24 dB at V.C. -9/+13.5 MHz NB ≥ 26 dB WB ≥ 26 dB (Typical) ≥ 30 dB ≤ 45 ns (Typical)

WB INPUT

NB INPUT

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

80

OUTPUT

400

UHF ATV COMBINERS

ELECTRICAL DATA

980


UC/U/LB4-30/M UHF ATV COMBINER

FEATURES UHF double bridge channel combiner 30 kW ATV NB Input power 4 Pole elliptical response/ 200 mm multisection 3dB couplers

SPECIFICATIONS FREQUENCY RANGE BANDWITH MIN. DISTANCE BETWEEN CH. TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT F G G F F F E F G E F F E E F B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

G=RL-120

ELECTRICAL DATA FCC M Standard

CCIR G Standard NB INSERTION LOSS (Typical)** ≤ 0.20 dB at C.F. WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 40 dB at V.C. -5.5/+11 MHz ≥ 24 dB at V.C. -11/+16.5 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB (Typical) DE-COUPLING ≥ 30 dB NB Group Delay Variation ≤ 45 ns (Typical)

≤ 0.25 dB at C.F. ≤ 0.08 dB ≥ 40 dB at V.C. -4.5/+9 MHz ≥ 24 dB at V.C. -9/+13.5 MHz NB ≥ 26 dB WB ≥ 26 dB (Typical) ≥ 30 dB ≤ 45 ns (Typical)

WB INPUT

OUTPUT

NB INPUT

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

81

UHF ATV COMBINERS

A=Nf

480

t

961

470 ÷ 862 MHz 6 to 8 MHz 1 guard channel ≤ 2 kHz/K -10 to + 50°C 40K at 30 kW ATV (NB) 120 Kg INPUTS / OUTPUT ATV (DTV) POWER * NB WB OUT 30kW (15kW) 60kW (40kW) 60kW (40kW) 30kW (15kW) 40kW (28kW) 40kW (28kW) 20kW (15kW) 40kW (28kW) 60kW (40kW) 20kW (15kW) 40kW (28kW) 40kW (28kW) 20kW (15kW) 20kW (15kW) 40kW (28kW) * referred to CCIR G standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

960



UHF DTV Combiners

85

UC/U/DVB-T/LB6-10/M

100

UC/U/DVB-T/M5-005/3

86

UC/U/DVB-T/LB8-01

101

UC/U/DVB-T/M5-005/4

87

UC/U/DVB-T/LB8-04

102

UC/U/DVB-T/M5-005/5

88

UC/U/DVB-T/LB8-1

103

UC/U/DVB-T/M5-005/6

89

UC/U/DVB-T/LB8-1/M

104

UC/U/DVB-T/M5-015/2

90

UC/U/DVB-T/LB8-2/M

105

UC/U/DVB-T/M5-015/3

91

UC/U/DVB-T/LB8-5/M

106

UC/U/DVB-T/M5-015/4

92

UC/U/DVB-T/LB8-10/M

107

UC/U/DVB-T/LB6-02

93

UC/U/DVB-T/LB6-05

94

UC/U/DVB-T/LB6-05/F

95

UC/U/DVB-T/LB6-1

96

UC/U/DVB-T/LB6-1/M

97

UC/U/DVB-T/LB6-2/M

98

UC/U/DVB-T/LB6-5/M

99

UHF DTV COMBINERS

UC/U/DVB-T/M5-005/2

SpeciямБcations are subject to change without prior notice

83



UC/U/DVB-T/M5-005/2 UHF DTV COMBINER

FEATURES UHF modular multiplexer 150 W channel input power (ATV) 50 W channel input power (DTV) 5 Pole / 40 mm 2 Inputs Low Loss Very compact and lightweight

TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS inputs / output

470 ÷ 862 MHz 50 W DTV (150 W ATV) 100 W DTV (300 W ATV) 6 to 8 MHz 1 guard channel (DVB 8 MHz) 2 guard channels (ATSC, DVB 7MHz) ≤ 15 kHz/K -10 to + 50°C 25K at 50 W DTV 1.8 Kg

132

SPECIFICATIONS FREQUENCY RANGE MAX CHANNEL INPUT POWER * MAX OUTPUT POWER BANDWITH MIN DISTANCE BETWEEN CH.

2 x NF / NF * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

SELECTIVITY RETURN LOSS DE-COUPLING GROUP DELAY

DVB 8 MHz N.C. Mask <1.30 dB at C.F. <1.70 dB at C.F. ±3.8 MHz >7 dB at C.F. ±6 MHz >36 dB at C.F. ±12 MHz >21 dB >30 dB <80 ns (Typical)

ATSC 6 MHz FCC Mask <1.40 dB at C.F. <1.60 dB at C.F. ±2.7 MHz >7 dB at C.F. ±6 MHz >28 dB at C.F. ±9 MHz >21 dB >30 dB <80 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

85

UHF DTV COMBINERS

INSERTION LOSS (Typical)**

203

ELECTRICAL DATA

81


UC/U/DVB-T/M5-005/3 UHF DTV COMBINER

FEATURES UHF modular multiplexer 150 W channel input power (ATV) 50 W channel input power (DTV) 5 Pole / 40 mm 3 Inputs Low Loss Very compact and lightweight

TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS inputs / output

470 ÷ 862 MHz 50 W DTV (150 W ATV) 150 W DTV (400 W ATV) 6 to 8 MHz 1 guard channel (DVB 8 MHz) 2 guard channels (ATSC, DVB 7MHz) ≤ 15 kHz/K -10 to + 50°C 25K at 50 W DTV 3 Kg

132

SPECIFICATIONS FREQUENCY RANGE MAX CHANNEL INPUT POWER * MAX OUTPUT POWER BANDWITH MIN DISTANCE BETWEEN CH.

3 x NF / NF * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** UHF DTV COMBINERS

SELECTIVITY RETURN LOSS DE-COUPLING GROUP DELAY

DVB 8 MHz N.C. Mask <1.30 dB at C.F. <1.70dB at C.F. ±3.8 MHz >7 dB at C.F. ±6 MHz >36 dB at C.F. ±12 MHz >21 dB >30 dB <80 ns (Typical)

ATSC 6 MHz FCC Mask <1.40 dB at C.F. <1.60 dB at C.F. ±2.7 MHz >7 dB at C.F. ±6 MHz >28 dB at C.F. ±9 MHz >21 dB >30 dB <80 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

86

203

ELECTRICAL DATA

121


UC/U/DVB-T/M5-005/4 UHF DTV COMBINER

FEATURES UHF modular multiplexer 150 W channel input power (ATV) 50 W channel input power (DTV) 5 Pole / 40 mm 4 Inputs Low Loss Very compact and lightweight

TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS inputs / output

470 ÷ 862 MHz 50 W DTV (150 W ATV) 200 W DTV (400 W ATV) 6 to 8 MHz 1 guard channel (DVB 8 MHz) 2 guard channels (ATSC, DVB 7MHz) ≤ 15 kHz/K -10 to + 50°C 25K at 50 W DTV 4 Kg

132

SPECIFICATIONS FREQUENCY RANGE MAX CHANNEL INPUT POWER * MAX OUTPUT POWER BANDWITH MIN DISTANCE BETWEEN CH.

4 x NF / NF * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

SELECTIVITY RETURN LOSS DE-COUPLING GROUP DELAY

DVB 8 MHz N.C. Mask <1.30 dB at C.F. <1.70 dB at C.F. ±3.8 MHz >7 dB at C.F. ±6 MHz >36 dB at C.F. ±12 MHz >21 dB >30 dB <80 ns (Typical)

ATSC 6 MHz FCC Mask <1.40 dB at C.F. <1.70 dB at C.F. ±2.7 MHz >7 dB at C.F. ±6 MHz >28 dB at C.F. ±9 MHz >21 dB >30 dB <80 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

87

UHF DTV COMBINERS

INSERTION LOSS (Typical)**

203

ELECTRICAL DATA

161


UC/U/DVB-T/M5-005/5 UHF DTV COMBINER

FEATURES UHF modular multiplexer 150 W channel input power (ATV) 50 W channel input power (DTV) 5 Pole / 40 mm 5 Inputs Low Loss Very compact and lightweight

TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS inputs / output

470 ÷ 862 MHz 50 W DTV (150 W ATV) 200 W DTV (400 W ATV) 6 to 8 MHz 1 guard channel (DVB 8 MHz) 2 guard channels (ATSC, DVB 7MHz) ≤ 15 kHz/K -10 to + 50°C 25K at 50 W DTV 5 Kg

132

SPECIFICATIONS FREQUENCY RANGE MAX CHANNEL INPUT POWER * MAX OUTPUT POWER BANDWITH MIN DISTANCE BETWEEN CH.

402

5 x NF / NF * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** UHF DTV COMBINERS

SELECTIVITY RETURN LOSS DE-COUPLING GROUP DELAY

DVB 8 MHz N.C. Mask <1.30 dB at C.F. <1.70 dB at C.F. ±3.8 MHz >7 dB at C.F. ±6 MHz >36 dB at C.F. ±12 MHz >21 dB >30 dB <80 ns (Typical)

ATSC 6 MHz FCC Mask <1.40 dB at C.F. <1.70 dB at C.F. ±2.7 MHz >7 dB at C.F. ±6 MHz >28 dB at C.F. ±9 MHz >21 dB >30 dB <80 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

88

121


UC/U/DVB-T/M5-005/6 UHF DTV COMBINER

FEATURES UHF modular multiplexer 150 W channel input power (ATV) 50 W channel input power (DTV) 5 Pole / 40 mm 6 Inputs Low Loss Very compact and lightweight

TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS inputs / output

470 ÷ 862 MHz 50 W DTV (150 W ATV) 200 W DTV (400 W ATV) 6 to 8 MHz 1 guard channel (DVB 8 MHz) 2 guard channels (ATSC, DVB 7MHz) ≤ 15 kHz/K -10 to + 50°C 25K at 50 W DTV 5.2 Kg

132

SPECIFICATIONS FREQUENCY RANGE MAX CHANNEL INPUT POWER * MAX OUTPUT POWER BANDWITH MIN DISTANCE BETWEEN CH.

402

6 x NF / NF * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

INSERTION LOSS (Typical)** SELECTIVITY RETURN LOSS DE-COUPLING GROUP DELAY

DVB 8 MHz N.C. Mask <1.30 dB at C.F. <1.70 dB at C.F. ±3.8 MHz >7 dB at C.F. ±6 MHz >36 dB at C.F. ±12 MHz >21 dB >30 dB <80 ns (Typical)

ATSC 6 MHz FCC Mask <1.40 dB at C.F. <1.70 dB at C.F. ±2.7 MHz >7 dB at C.F. ±6 MHz >28 dB at C.F. ±9 MHz >21 dB >30 dB <80 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

89

UHF DTV COMBINERS

ELECTRICAL DATA

121


UC/U/DVB-T/M5-015/2 UHF DTV COMBINER

FEATURES UHF modular multiplexer 300 W channel input power (ATV) 150 W channel input power (DTV) 5 Pole / 50 mm 2 Inputs Low Loss Very compact and lightweight

TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS inputs / output

470 ÷ 862 MHz 150 W DTV (300 W ATV) 300 W DTV (600 W ATV) 6 to 8 MHz 1 guard channel (DVB 8 MHz) 2 guard channels (ATSC, DVB 7MHz) ≤ 15 kHz/K -10 to + 50°C 30K at 150 W DTV 3 Kg

157

SPECIFICATIONS FREQUENCY RANGE MAX CHANNEL INPUT POWER * MAX OUTPUT POWER BANDWITH MIN DISTANCE BETWEEN CH.

279

2 x NF / 7/16 F * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** UHF DTV COMBINERS

SELECTIVITY RETURN LOSS DE-COUPLING GROUP DELAY

DVB 8 MHz N.C. Mask <1.0 dB at C.F. <1.50 dB at C.F. ±3.8 MHz >7 dB at C.F. ±6 MHz >36 dB at C.F. ±12 MHz >21 dB >30 dB <80 ns (Typical)

ATSC 6 MHz FCC Mask <1.10 dB at C.F. <1.40 dB at C.F. ±2.7 MHz >7 dB at C.F. ±6 MHz >28 dB at C.F. ±9 MHz >21 dB >30 dB <80 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

90

113


UC/U/DVB-T/M5-015/3 UHF DTV COMBINER

FEATURES UHF modular multiplexer 300 W channel input power (ATV) 150 W channel input power (DTV) 5 Pole / 50 mm 3 Inputs Low Loss Very compact and lightweight

TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS inputs / output

470 ÷ 862 MHz 150 W DTV (300 W ATV) 450 W DTV (800 W ATV) 6 to 8 MHz 1 guard channel (DVB 8 MHz) 2 guard channels (ATSC, DVB 7MHz) ≤ 15 kHz/K -10 to + 50°C 30K at 150 W DTV 3 Kg

157

SPECIFICATIONS FREQUENCY RANGE MAX CHANNEL INPUT POWER * MAX OUTPUT POWER BANDWITH MIN DISTANCE BETWEEN CH.

3 x NF / 7/16 F * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

SELECTIVITY RETURN LOSS DE-COUPLING GROUP DELAY

DVB 8 MHz N.C. Mask <1.0 dB at C.F. <1.50 dB at C.F. ±3.8 MHz >7 dB at C.F. ±6 MHz >36 dB at C.F. ±12 MHz >21 dB >30 dB <80 ns (Typical)

ATSC FCC Mask <1.10 dB at C.F. <1.40 dB at C.F. ±2.7 MHz >7 dB at C.F. ±6 MHz >28 dB at C.F. ±9 MHz >21 dB >30 dB <80 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

91

UHF DTV COMBINERS

INSERTION LOSS (Typical)**

279

ELECTRICAL DATA

169


UC/U/DVB-T/M5-015/4 UHF DTV COMBINER

FEATURES UHF modular multiplexer 300 W channel input power (ATV) 150 W channel input power (DTV) 5 Pole / 50 mm 4 Inputs Low Loss Very compact and lightweight

TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS inputs / output

470 ÷ 862 MHz 150 W DTV (300 W ATV) 500 W DTV (800 W ATV) 6 to 8 MHz 1 guard channel (DVB 8 MHz) 2 guard channels (ATSC, DVB 7MHz) ≤ 15 kHz/K -10 to + 50°C 30K at 150 W DTV 4 Kg

157

SPECIFICATIONS FREQUENCY RANGE MAX CHANNEL INPUT POWER * MAX OUTPUT POWER BANDWITH MIN DISTANCE BETWEEN CH.

4 x NF / 7/16 F

329

* referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C

ELECTRICAL DATA INSERTION LOSS (Typical)** UHF DTV COMBINERS

SELECTIVITY RETURN LOSS DE-COUPLING GROUP DELAY

DVB 8 MHz N.C. Mask <1.0 dB at C.F. <1.50 dB at C.F. ±3.8 MHz >7 dB at C.F. ±6 MHz >36 dB at C.F. ±12 MHz >21 dB >30 dB <80 ns (Typical)

ATSC 6 MHz FCC Mask <1.10 dB at C.F. <1.40 dB at C.F. ±2.7 MHz >7 dB at C.F. ±6 MHz >28 dB at C.F. ±9 MHz >21 dB >30 dB <80 ns (Typical)

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

92

227


UC/U/DVB-T/LB6-02 UHF DTV COMBINER

FEATURES UHF DTV double bridge channel combiner 200 W NB Input power DVB/ATSC applications 6 Pole / 40 mm

SPECIFICATIONS FREQUENCY RANGE BANDWITH MIN. DISTANCE BETWEEN CH. TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT B B B A A A

t

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

263

470 ÷ 862 MHz 6 to 8 MHz 1 guard channel ≤ 10 kHz/K -10 to + 50°C 30K at 200 W DTV (NB) 6.7 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 200W (300W) 400W (600W) 400W (600W) 200W (300W) 200W (300W) 200W (300W) * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120 WB INPUT

OUTPUT

ATSC 6 MHz Mask ≤ 1.65 dB at C.F. ≤ 2.25 dB at C.F. ±2.7 MHz ≤ 0.08 dB ≥ 4 dB at C.F. ± 3.5 MHz ≥ 12 dB at C.F. ± 6 MHz ≥ 36 dB at C.F. ± 9 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 150 ns (Typical)

UHF DTV COMBINERS

DVB 8 MHz Mask NB INSERTION LOSS (Typical)** ≤ 1.45 dB at C.F. ≤ 1.95 dB at C.F. ±3.8 MHz ≤ 0.08 dB WB INSERTION LOSS ≥ 2 dB at C.F. ± 4.2 MHz SELECTIVITY ≥ 12 dB at C.F. ± 6 MHz ≥ 36 dB at C.F. ± 12 MHz NB ≥ 26 dB RETURN LOSS WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB DE-COUPLING GROUP DELAY VARIATION ≤ 150 ns (Typical)

284

ELECTRICAL DATA

NB INPUT

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

93

175


UC/U/DVB-T/LB6-05 UHF DTV COMBINER

FEATURES UHF DTV double bridge channel combiner 500 W NB Input power DVB/ATSC applications 6 Pole / 50 mm

SPECIFICATIONS FREQUENCY RANGE BANDWITH MIN. DISTANCE BETWEEN CH. TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT C C C B B B

t

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

366

470 ÷ 862 MHz 6 to 8 MHz 1 guard channel ≤ 10 kHz/K -10 to + 50°C 30K at 500 W DTV (NB) 8 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 500W (750W) 2kW (3kW) 2kW (3kW) 500W (750W) 1kW (1.5kW) 1kW (1.5kW) * referred to DVB-T 8 MHz standard, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120 WB INPUT

OUTPUT

UHF DTV COMBINERS

DVB 8 MHz Mask NB INSERTION LOSS (Typical)** ≤ 1.15 dB at C.F. ≤ 1.85 dB at C.F. ±3.8 MHz WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 2 dB at C.F. ± 4.2 MHz ≥ 12 dB at C.F. ± 6 MHz ≥ 36 dB at C.F. ± 12 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 150 ns (Typical)

ATSC 6 MHz Mask ≤ 1.35 dB at C.F. ≤ 2.05 dB at C.F. ±3.8 MHz ≤ 0.08 dB ≥ 4 dB at C.F. ± 3.5 MHz ≥ 12 dB at C.F. ± 6 MHz ≥ 36 dB at C.F. ± 9 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 150 ns (Typical)

363

ELECTRICAL DATA

NB INPUT

** A tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

94

191


UC/U/DVB-T/LB6-05/F UHF DTV COMBINER

FEATURES UHF DTV double bridge channel combiner 500 W NB Input power DVB/ATSC applications 6 Pole / 50 mm suitable for adjacent channel combination

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT C C C B B B

t

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

397

470 ÷ 862 MHz 6 to 8 MHz ≤ 4 kHz/K -10 to + 50°C 30K at 500 W DTV (NB) 8 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 500W (750W) 2kW (3kW) 2kW (3kW) 500W (750W) 1kW (1.5kW) 1kW (1.5kW) * referred to DVB-T 8 MHz standard, no adjacent channels, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120

ELECTRICAL DATA

WB INPUT

NB INPUT

** No adjacent channels, tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

95

OUTPUT

336

UHF DTV COMBINERS

ATSC 6 MHz Mask ≤ 1.55 dB at C.F. ≤ 2.75 dB at C.F. ±2.7 MHz ≤ 0.08 dB ≥ 6 dB at C.F. ± 3.5 MHz ≥ 25 dB at C.F. ± 6 MHz ≥ 45 dB at C.F. ± 9 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 150 ns (Typical)

147

DVB 8 MHz Mask NB INSERTION LOSS (Typical)** ≤ 0.95 dB at C.F. ≤ 2.25 dB at C.F. ±3.8 MHz ≤ 0.08 dB WB INSERTION LOSS ≥ 4 dB at C.F. ± 4.2 MHz SELECTIVITY ≥ 16 dB at C.F. ± 6 MHz ≥ 42 dB at C.F. ± 12 MHz NB ≥ 26 dB RETURN LOSS WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB DE-COUPLING GROUP DELAY VARIATION ≤ 250 ns (Typical)


UC/U/DVB-T/LB6-1 UHF DTV COMBINER

FEATURES UHF DTV double bridge channel combiner 1 kW NB Input power DVB/ATSC applications 6 Pole elliptical response/ 85 mm suitablef oradjacent channel com bination

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT D D D C D D

t

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

650

470 ÷ 862 MHz 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 1 kW DTV (NB) 21.5 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 1kW (1.5kW) 5kW (7.5kW) 5kW (7.5kW) 1kW (1.5kW) 5kW (7.5kW) 5kW (7.5kW) * referred to DVB-T 8 MHz standard, no adjacent channels, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120

ELECTRICAL DATA ATSC 6 MHz Mask ≤ 0.75 dB at C.F. ≤ 1.35 dB at C.F. ±2.7 MHz ≤ 0.08 dB ≥ 6 dB at C.F. ± 3.5 MHz ≥ 25 dB at C.F. ± 6 MHz ≥ 45 dB at C.F. ± 9 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 150 ns (Typical)

WB INPUT

NB INPUT

** No adjacent channels, tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

96

OUTPUT

250

UHF DTV COMBINERS

DVB 8 MHz Mask NB INSERTION LOSS (Typical)** ≤ 0.50 dB at C.F. ≤ 1.50 dB at C.F. ±3.8 MHz WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 4 dB at C.F. ± 4.2 MHz ≥ 16 dB at C.F. ± 6 MHz ≥ 42 dB at C.F. ± 12 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 250 ns (Typical)

480


UC/U/DVB-T/LB6-1/M UHF DTV COMBINER

FEATURES UHF DTV double bridge channel combiner 1 kW NB Input power DVB/ATSC applications 6 Pole elliptical response/ 85 mm multisection 3dB coupl ers suitable for adjacent channel combination

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT D D D C D D

t

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

605

470 ÷ 862 MHz 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 1 kW DTV (NB) 23 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 1kW (1.5kW) 5kW (7.5kW) 5kW (7.5kW) 1kW (1.5kW) 5kW (7.5kW) 5kW (7.5kW) * referred to DVB-T 8 MHz standard, no adjacent channels, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120

ELECTRICAL DATA

WB INPUT

NB INPUT

** No adjacent channels, tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

97

OUTPUT

638

UHF DTV COMBINERS

ATSC 6 MHz Mask ≤ 0.75 dB at C.F. ≤ 1.35 dB at C.F. ±2.7 MHz ≤ 0.08 dB ≥ 6 dB at C.F. ±3.5 MHz ≥ 25 dB at C.F. ±6 MHz ≥ 45 dB at C.F. ±9 MHz NB ≥ 26 dB WB ≥ 26 dB (Typical) ≥ 30 dB ≤ 150 ns (Typical)

240

DVB 8 MHz Mask NB INSERTION LOSS (Typical)** ≤ 0.50 dB at C.F. ≤ 1.50 dB at C.F. ±3.8 MHz WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 4 dB at C.F. ±4.2 MHz ≥ 16 dB at C.F. ±6 MHz ≥ 42 dB at C.F. ±12 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB (Typical) DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 250 ns (Typical)


UC/U/DVB-T/LB6-2/M UHF DTV COMBINER

FEATURES UHF DTV double bridge channel combiner 2 kW NB Input power DVB/ATSC applications 6 Pole elliptical response/ 120 mm multisection 3dB coupl ers suitable for adjacent channel combination

470 ÷ 862 MHz 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 2 kW DTV (NB) 33 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 2kW (3kW) 10kW (15kW) 10kW (15kW) 2kW (3kW) 5kW (7.5kW) 7kW (10kW) 2kW (3kW) 5kW (7.5kW) 5kW (7.5kW)

737

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT D E E D D E D D D

* referred to DVB-T 8 MHz standard, no adjacent channels, recommended: [AmbientTemp. + OverTemp.] ≤60°C t

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

G=RL-120

ELECTRICAL DATA ATSC 6 MHz Mask ≤ 0.65 dB at C.F. ≤ 1.05 dB at C.F. ±2.7 MHz ≤ 0.08 dB ≥ 6 dB at C.F. ±3.5 MHz ≥ 25 dB at C.F. ±6 MHz ≥ 45 dB at C.F. ±9 MHz NB ≥ 26 dB WB ≥ 26 dB (Typical) ≥ 30 dB ≤ 150 ns (Typical)

WB INPUT

NB INPUT

** No adjacent channels, tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

98

OUTPUT

300

UHF DTV COMBINERS

DVB 8 MHz Mask NB INSERTION LOSS (Typical)** ≤ 0.45 dB at C.F. ≤ 1.30 dB at C.F. ±3.8 MHz WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 4 dB at C.F. ±4.2 MHz ≥ 16 dB at C.F. ±6 MHz ≥ 42 dB at C.F. ±12 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB (Typical) DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 250 ns (Typical)

740


UC/U/DVB-T/LB6-5/M UHF DTV COMBINER

FEATURES UHF DTV double bridge channel combiner 5 kW NB Input power DVB/ATSC applications 6 Pole elliptical response/ 150 mm multisection 3dB coupl ers suitable for adjacent channel combination

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT E E E D D E D E E

470 ÷ 862 MHz 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 5 kW DTV (NB) 75 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 5kW (7.5kW) 15kW (20kW) 15kW (20kW) 5kW (7.5kW) 5kW (7.5kW) 10kW (15kW) 5kW (7.5kW) 15kW (20kW) 15kW (20kW)

t

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

900

* referred to DVB-T 8 MHz standard, no adjacent channels, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120

ELECTRICAL DATA

WB INPUT

NB INPUT

** No adjacent channels, tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

99

OUTPUT

960

UHF DTV COMBINERS

ATSC 6 MHz Mask ≤ 0.55 dB at C.F. ≤ 0.95 dB at C.F. ±2.7 MHz ≤ 0.08 dB ≥ 6 dB at C.F. ±3.5 MHz ≥ 25 dB at C.F. ±6 MHz ≥ 45 dB at C.F. ±9 MHz NB ≥ 26 dB WB ≥ 26 dB (Typical) ≥ 30 dB ≤ 150 ns (Typical)

400

DVB 8 MHz Mask NB INSERTION LOSS (Typical)** ≤ 0.35 dB at C.F. ≤ 1.15 dB at C.F. ±3.8 MHz WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 4 dB at C.F. ±4.2 MHz ≥ 16 dB at C.F. ±6 MHz ≥ 42 dB at C.F. ±12 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB (Typical) DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 250 ns (Typical)


UC/U/DVB-T/LB6-10/M UHF DTV COMBINER

FEATURES UHF DTV double bridge channel combiner 10 kW NB Input power DVB/ATSC applications 6 Pole elliptical response/ 200 mm multisection 3dB coupl ers suitable for adjacent channel combination SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT E G G E F G E F F E E F E E E D F F D E E

t

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

1150

470 ÷ 862 MHz 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 25K at 10 kW DTV (NB) 140 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 10kW (15kW) 40kW (60kW) 40kW (60kW) 10kW (15kW) 28kW (40kW) 38kW (55kW) 10kW (15kW) 28kW (40kW) 28kW (40kW) 10kW (15kW) 15kW (20kW) 25kW (35kW) 10kW (15kW) 15kW (20kW) 15kW (20kW) 5kW (7.5kW) 28kW (40kW) 28kW (40kW) 5kW (7.5kW) 15kW (20kW) 15kW (20kW) * referred to DVB-T 8 MHz standard, no adjacent channels, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120

ELECTRICAL DATA ATSC 6 MHz Mask ≤ 0.35 dB at C.F. ≤ 0.55 dB at C.F. ±2.7 MHz ≤ 0.08 dB ≥ 6 dB at C.F. ±3.5 MHz ≥ 25 dB at C.F. ±6 MHz ≥ 45 dB at C.F. ±9 MHz NB ≥ 26 dB WB ≥ 26 dB (Typical) ≥ 30 dB ≤ 150 ns (Typical)

WB INPUT

NB INPUT

** No adjacent channels, tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

100

OUTPUT

480

UHF DTV COMBINERS

DVB 8 MHz Mask NB INSERTION LOSS (Typical)** ≤ 0.30 dB at C.F. ≤ 0.75 dB at C.F. ±3.8 MHz WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 4 dB at C.F. ±4.2 MHz ≥ 16 dB at C.F. ±6 MHz ≥ 42 dB at C.F. ±12 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB (Typical) DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 250 ns (Typical)

960


UC/U/DVB-T/LB8-01 UHF DTV COMBINER

FEATURES UHF DTV double bridge channel combiner 100 W NB Input power DVB applications 8 Pole / 40 mm suitable for adjacent channel combination

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT B B B A A A

t

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

268

470 ÷ 862 MHz 6 to 8 MHz ≤ 10 kHz/K -10 to + 50°C 30K at 100 W DTV (NB) 8 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 100W (150W) 400W (600W) 400W (600W) 100W (150W) 200W (300W) 200W (300W) * referred to DVB-T 8 MHz standard, no adjacent channels, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120

WB INPUT

ELECTRICAL DATA

UHF DTV COMBINERS

207

DVB 8 MHz Mask NB INSERTION LOSS (Typical)** ≤ 2.05 dB at C.F. ≤ 5.05 dB at C.F. ±3.8 MHz ≤ 0.08 dB WB INSERTION LOSS ≥ 12 dB at C.F. ± 4.2 MHz SELECTIVITY ≥ 30 dB at C.F. ± 6 MHz ≥ 55 dB at C.F. ± 12 MHz NB ≥ 26 dB RETURN LOSS WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB DE-COUPLING GROUP DELAY VARIATION ≤ 450 ns (Typical)

OUTPUT

NB INPUT 175

** No adjacent channels, tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

101


UC/U/DVB-T/LB8-04 UHF DTV COMBINER

FEATURES UHF DTV double bridge channel combiner 400 W NB Input power DVB/ATSC applications 8 Pole elliptical response / 50 mm suitable for adjacent channel combination

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT C C C B B B

t

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

466

470 ÷ 862 MHz 6 to 8 MHz ≤ 4 kHz/K -10 to + 50°C 30K at 400 W DTV (NB) 9.8 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 400W (600W) 2kW (3kW) 2kW (3kW) 400W (600W) 1kW (1.5kW) 1kW (1.5kW) * referred to DVB-T 8 MHz standard, no adjacent channels, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120

ELECTRICAL DATA ATSC 6 MHz Mask ≤ 1.85 dB at C.F. ≤ 5.25 dB at C.F. ±2.85 MHz ≤ 0.08 dB ≥ 14 dB at C.F. ±3.15 MHz ≥ 30 dB at C.F. ±4.5 MHz ≥ 50 dB at C.F. ±9 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 450 ns (Typical)

** No adjacent channels, tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

102

WB INPUT

OUTPUT

147

UHF DTV COMBINERS

DVB 8 MHz Mask NB INSERTION LOSS (Typical)** ≤ 1.55 dB at C.F. ≤ 4.55 dB at C.F. ±3.8 MHz ≤ 0.08 dB WB INSERTION LOSS ≥ 12 dB at C.F. ± 4.2 MHz SELECTIVITY ≥ 30 dB at C.F. ± 6 MHz ≥ 55 dB at C.F. ± 12 MHz NB ≥ 26 dB RETURN LOSS WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB DE-COUPLING GROUP DELAY VARIATION ≤ 450 ns (Typical)

NB INPUT 336


UC/U/DVB-T/LB8-1 UHF DTV COMBINER

FEATURES UHF DTV double bridge channel combiner 1 kW NB Input power DVB/ATSC applications 8 Pole elliptical response/ 85 mm suitablef or adjacent channel com bination

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT D D D C D D

t

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

730

470 ÷ 862 MHz 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 1 kW DTV (NB) 24.5 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 1kW (1.5kW) 5kW (7.5kW) 5kW (7.5kW) 1kW (1.5kW) 5kW (7.5kW) 5kW (7.5kW) * referred to DVB-T 8 MHz standard, no adjacent channels, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120

ELECTRICAL DATA

WB INPUT

NB INPUT

** No adjacent channels, tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

103

OUTPUT

480

UHF DTV COMBINERS

ATSC 6 MHz Mask ≤ 1.05 dB at C.F. ≤ 3.90 dB at C.F. ±2.85 MHz ≤ 0.08 dB ≥ 14 dB at C.F. ±3.15 MHz ≥ 30 dB at C.F. ±4.5 MHz ≥ 50 dB at C.F. ±9 MHz NB ≥ 26 dB WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB ≤ 450 ns (Typical)

250

DVB 8 MHz Mask NB INSERTION LOSS (Typical)** ≤ 0.90 dB at C.F. ≤ 3.05 dB at C.F. ±3.8 MHz ≤ 0.08 dB WB INSERTION LOSS ≥ 12 dB at C.F. ± 4.2 MHz SELECTIVITY ≥ 30 dB at C.F. ± 6 MHz ≥ 55 dB at C.F. ± 12 MHz NB ≥ 26 dB RETURN LOSS WB ≥ 26 dB on specified channel or WB ≥ 23 dB ≥ 30 dB DE-COUPLING GROUP DELAY VARIATION ≤ 450 ns (Typical)


UC/U/DVB-T/LB8-1/M UHF DTV COMBINER

FEATURES UHF DTV double bridge channel combiner 1 kW NB Input power DVB/ATSC applications 8 Pole elliptical response/ 85 mm multisection 3dB coupl ers suitable for adjacent channel combination

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT D D D C D D

t

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

690

470 ÷ 862 MHz 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 1 kW DTV (NB) 26 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 1kW (1.5kW) 5kW (7.5kW) 5kW (7.5kW) 1kW (1.5kW) 5kW (7.5kW) 5kW (7.5kW) * referred to DVB-T 8 MHz standard, no adjacent channels, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120

ELECTRICAL DATA ATSC 6 MHz Mask ≤ 1.05 dB at C.F. ≤ 3.90 dB at C.F. ±2.85 MHz ≤ 0.08 dB ≥ 14 dB at C.F. ±3.15 MHz ≥ 30 dB at C.F. ±4.5 MHz ≥ 50 dB at C.F. ±9 MHz NB ≥ 26 dB WB ≥ 26 dB (Typical) ≥ 30 dB ≤ 450 ns (Typical)

WB INPUT

NB INPUT

** No adjacent channels, tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

104

OUTPUT

240

UHF DTV COMBINERS

DVB 8 MHz Mask NB INSERTION LOSS (Typical)** ≤ 0.90 dB at C.F. ≤ 3.05 dB at C.F. ±3.8 MHz WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 12 dB at C.F. ±4.2 MHz ≥ 30 dB at C.F. ±6 MHz ≥ 55 dB at C.F. ±12 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB (Typical) DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 450 ns (Typical)

638


UC/U/DVB-T/LB8-2/M UHF DTV COMBINER

FEATURES UHF DTV double bridge channel combiner 2 kW NB Input power DVB/ATSC applications 8 Pole elliptical response/ 120 mm multisection 3dB coupl ers suitable for adjacent channel combination

470 ÷ 862 MHz 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 2 kW DTV (NB) 39 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 2kW (3kW) 10kW (15kW) 10kW (15kW) 2kW (3kW) 5kW (7.5kW) 7kW (10.5kW) 2kW (3kW) 5kW (7.5kW) 5kW (7.5kW)

860

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT D E E D D E D D D

* referred to DVB-T 8 MHz standard, no adjacent channels, recommended: [AmbientTemp. + OverTemp.] ≤60°C t

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

G=RL-120

ELECTRICAL DATA

WB INPUT

NB INPUT

** No adjacent channels, tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

105

OUTPUT

740

UHF DTV COMBINERS

ATSC 6 MHz Mask ≤ 0.85 dB at C.F. ≤ 3.50 dB at C.F. ±2.85 MHz ≤ 0.08 dB ≥ 14 dB at C.F. ±3.15 MHz ≥ 30 dB at C.F. ±4.5 MHz ≥ 50 dB at C.F. ±9 MHz NB ≥ 26 dB WB ≥ 26 dB (Typical) ≥ 30 dB ≤ 450 ns (Typical)

300

DVB 8 MHz Mask NB INSERTION LOSS (Typical)** ≤ 0.70 dB at C.F. ≤ 2.55 dB at C.F. ±3.8 MHz WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 12 dB at C.F. ±4.2 MHz ≥ 30 dB at C.F. ±6 MHz ≥ 55 dB at C.F. ±12 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB (Typical) DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 450 ns (Typical)


UC/U/DVB-T/LB8-5/M UHF DTV COMBINER

FEATURES UHF DTV double bridge channel combiner 5 kW NB Input power DVB/ATSC applications 8 Pole elliptical response/ 150 mm multisection 3dB coupl ers suitable for adjacent channel combination

470 ÷ 862 MHz 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 5 kW DTV (NB) 90 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 5kW (7.5kW) 15kW (20kW) 15kW (20kW) 5kW (7.5kW) 15kW (20kW) 15kW (20kW) 5kW (7.5kW) 5kW (7.5kW) 10kW (15kW)

1062

SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT E E E D E E D D E

* referred to DVB-T 8 MHz standard, no adjacent channels, recommended: [AmbientTemp. + OverTemp.] ≤60°C t

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

G=RL-120

ELECTRICAL DATA ATSC 6 MHz Mask ≤ 0.75 dB at C.F. ≤ 2.90 dB at C.F. ±2.85 MHz ≤ 0.08 dB ≥ 14 dB at C.F. ±3.15 MHz ≥ 30 dB at C.F. ±4.5 MHz ≥ 50 dB at C.F. ±9 MHz NB ≥ 26 dB WB ≥ 26 dB (Typical) ≥ 30 dB ≤ 450 ns (Typical)

WB INPUT

NB INPUT

** No adjacent channels, tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

106

OUTPUT

400

UHF DTV COMBINERS

DVB 8 MHz Mask NB INSERTION LOSS (Typical)** ≤ 0.60 dB at C.F. ≤ 2.05 dB at C.F. ±3.8 MHz WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 12 dB at C.F. ±4.2 MHz ≥ 30 dB at C.F. ±6 MHz ≥ 55 dB at C.F. ±12 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB (Typical) DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 450 ns (Typical)

960


UC/U/DVB-T/LB8-10/M UHF DTV COMBINER

FEATURES UHF DTV double bridge channel combiner 10 kW NB Input power DVB/ATSC applications 8 Pole elliptical response/ 200 mm multisection 3dB couplers suitable for adjacent channel combination SPECIFICATIONS FREQUENCY RANGE BANDWITH TEMPERATURE STABILITY OPERATING TEMPERATURE OVER TEMPERATURE * WEIGHT (approx) CONNECTORS t NB WB OUT E G G E F G E F F E E F E E E D F F D E E

t

A=Nf

B=7/16f

C= 7/8”unfl or EIA

D=1-5/8”unfl

E=3-1/8”unfl

F=4-1/2”unfl

1360

470 ÷ 862 MHz 6 to 8 MHz ≤ 2 kHz/K -10 to + 50°C 30K at 10 kW DTV (NB) 170 Kg INPUTS / OUTPUT DTV (ATV) POWER * NB WB OUT 10kW (15kW) 40kW (60kW) 40kW (60kW) 10kW (15kW) 28kW (40kW) 38kW (55kW) 10kW (15kW) 28kW (40kW) 28kW (40kW) 10kW (15kW) 15kW (20kW) 25kW (35kW) 10kW (15kW) 15kW (20kW) 15kW (20kW) 5kW (7.5kW) 28kW (40kW) 28kW (40kW) 5kW (7.5kW) 15kW (20kW) 15kW (20kW) * referred to DVB-T 8 MHz standard, no adjacent channels, recommended: [AmbientTemp. + OverTemp.] ≤60°C G=RL-120

ELECTRICAL DATA

NB INPUT

** No adjacent channels, tolerance of 0.05dB could be applied at stated value on the basis of operating channel

Specifications are subject to change without prior notice

107

OUTPUT

WB INPUT

960

UHF DTV COMBINERS

ATSC 6 MHz Mask ≤ 0.60 dB at C.F. ≤ 2.20 dB at C.F. ±2.85 MHz ≤ 0.08 dB ≥ 14 dB at C.F. ±3.15 MHz ≥ 30 dB at C.F. ±4.5 MHz ≥ 50 dB at C.F. ±9 MHz NB ≥ 26 dB WB ≥ 26 dB (Typical) ≥ 30 dB ≤ 450 ns (Typical)

480

DVB 8 MHz Mask NB INSERTION LOSS (Typical)** ≤ 0.55 dB at C.F. ≤ 1.65 dB at C.F. ±3.8 MHz WB INSERTION LOSS ≤ 0.08 dB SELECTIVITY ≥ 12 dB at C.F. ±4.2 MHz ≥ 30 dB at C.F. ±6 MHz ≥ 55 dB at C.F. ±12 MHz RETURN LOSS NB ≥ 26 dB WB ≥ 26 dB (Typical) DE-COUPLING ≥ 30 dB GROUP DELAY VARIATION ≤ 450 ns (Typical)



Rigid Lines

111

Fine Matchers

113

Directional Couplers

116

Frequency Equalized Directional Couplers

118

Coaxial Elbows

122

UHF 3dB Couplers

127

Cable Test Sections

128

Coaxials Accessories

130

SpeciďŹ cations are subject to change without prior notice

109

COAXIAL COMPONENTS

Coaxial Components



RIGID LINES

FEATURES flanged / unflanged rigid lines low insertion losses low V.S.W.R indoor / outdoor applications*

GENERAL FEATURES FREQUENCY RANGE IMPEDANCE RETURN LOSS MAX MEAN POWER LENGHT WEIGHT OPERATING TEMPERATURE RANGE MATERIALS - Outer conductor - Inner conductor - Insulating material TERMINATED TYPE

0.1 ÷ 860 MHz 50 ohm ≥ 32 dB See table 0.1 ÷ 4 m (typical 4 m) See table -40 ÷ +70° C Polished Copper / Aluminium Polished Copper Teflon EIA Flanged / EIA Unflanged

* only for flanged types

MAX MEAN POWER (kW) 300 200

100

6-1/8” RL 120 4-1/2”

50

20

3-1/8” 10

1-5/8”

5

7/8”

0.5

N

0.2 40

50

VHF-BI

100

200

FM

VHF-BIII

1000

500

(MHz)

UHF Specifications are subject to change without prior notice

111

STANDARD CONDITIONS: V.S.W.R. = 1.0 Ambient temperature 40°C Atmospheric Pressure, DryAir Inner Conductor Temperature 120°C

COAXIAL COMPONENTS

7/16

1


RIGID LINES

EIA UNFLANGED RIGID LINES DIMENSIONS (mm) TYPE 7/8” 1-5/8” 3-1/8” 4-1/2” RL 120 6-1/8”

Outer conductor (A/B)

Inner conductor (C/D)

E

WEIGHT (kg/m)

22.3 / 20 41.27 / 38.78 79.4 / 76.88 106 / 103 123 / 120 155.6 / 151.9

8.7 / 7.4 16.87 / 14.93 33.4 / 31.26 44.8 / 42.8 52.1 / 50.1 66 / 64

10.5 11 18 18 0 26

0.33 1.83 3.75 5.6 3 9.76

EIA FLANGED RIGID LINES DIMENSIONS (mm) TYPE 7/8” 1-5/8” 3-1/8” 4-1/2” 6-1/8”

Outer conductor (A/B)

Inner conductor (C/D)

E

WEIGHT (kg/m)

25 / 20 41.27 / 38.78 79.4 / 76.88 106 / 103 155.6 / 151.9

8.7 / 7.4 16.87 / 14.93 33.4 / 31.26 44.8 / 42.8 66 / 64

58 89 128 159 206

2 2.7 5.2 7.9 14.5

COAXIAL COMPONENTS

Specifications are subject to change without prior notice

112


FINE MATCHERS

FEATURES flanged / unflanged fine matchers low insertion losses low V.S.W.R indoor / outdoor applications*

GENERAL FEATURES FREQUENCY RANGE IMPEDANCE RETURN LOSS MAX MEAN POWER OPERATING TEMPERATURE RANGE CONNECTORS WEIGHT PRESSURIZATION * MATERIALS - External body - Inner conductor - Insulator EXTERNAL FINISHING

See table 50 ohm ≥ 32 dB See table below -40 ÷ +70° C See table below See table below Typical operating pressure 300 hPa (300 mBar) Polished copper, polished brass, Aluminium Silver plated brass Teflon Painted Ral 7001, Passivation SURTEC 650

* only for flanged types

MAX MEAN POWER (kW) 300 200

100

6-1/8” RL 120 4-1/2”

50

20

3-1/8” 10

1-5/8”

5

7/8”

0.5

N

0.2 40

50

VHF-BI

100

200

FM

VHF-BIII

1000

500

(MHz)

UHF Specifications are subject to change without prior notice

113

STANDARD CONDITIONS: V.S.W.R. = 1.0 Ambient temperature 40°C Atmospheric Pressure, DryAir Inner Conductor Temperature 120°C

COAXIAL COMPONENTS

7/16

1


FINE MATCHERS

figure “1”

TYPE

COAXIAL COMPONENTS

FMBP1-03 FMBP-03 FMBP-04 FMBPFM-03 FMBPFM-07 FMFM-03 FMFM-04 FMFM-06 FMFM-07 FMBT-03 FMBT-04 FMTV-03 FMTV-04 FMTV-06/SP FMTV-07

FREQUENCY RANGE (MHz)

CONNECTORS

47 ÷ 57 66 ÷ 88 66 ÷ 88 76 ÷ 108 76 ÷ 108 87.5 ÷ 108 87.5 ÷ 108 87.5 ÷ 108 87.5 ÷ 108 174 ÷ 230 174 ÷ 230 470 ÷ 860 470 ÷ 860 470 ÷ 860 470 ÷ 860

1-5/8” EIA 1-5/8” EIA 3-1/8” EIA 1-5/8” EIA 4-1/2” EIA 1-5/8” EIA 3-1/8” EIA 6-1/8” EIA 4-1/2” EIA 1-5/8” EIA 3-1/8” EIA 1-5/8” EIA 3-1/8” EIA 6-1/8” EIA 4-1/2” EIA

figure “2”

DIMENSIONS A (mm)

B (mm)

C (mm)

WEIGHT (kg)

1442 980 950 816 816 764 764 764 764 370 370 354 390 520 442

127.5 127.5 208.7 127.5 264.5 127.5 208.7 363 264.5 127.5 208.7 121.2 183.5 265 233.5

89 89 128 89 159 89 128 206 159 89 128 89 128 206 159

6.5 6 7.5 5 10 4 6.5 17.5 9 3.2 4 5 7.4 16 10.5

FIGURE 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2

Specifications are subject to change without prior notice

114


FINE MATCHERS

figure “1”

figure “2” C

B

A

TYPE TRIM-01 TRIM-02 TRIM-05 TRIM-15 TRIM-08 TRIM-18

CONNECTORS NF - NF 7/16F - 7/16F 7/8” Unfl - 7/8” Unfl. 1-5/8” Unfl. - 1-5/8” Unfl. 3-1/8” Unfl. - 3-1/8” Unfl. 4-1/2” Unfl. - 4-1/2” Unfl.

DIMENSIONS A (mm)

B (mm)

C (mm)

WEIGHT (kg)

150 162.5 235 348 407.5 433

35.5 35.5 60 90 142 180

32 32 58 41.3 79.4 106

0.7 0.9 1 1.3 3.9 7.1

FIGURE 1 1 2 2 2 2

Note: M = male / F = female Specifications are subject to change without prior notice

115

COAXIAL COMPONENTS

UHF 470 - 862 MHz TRIMMER LINES


DIRECTIONAL COUPLERS

FEATURES flanged / unflanged directional couplers low insertion losses low V.S.W.R high directivity value indoor / outdoor applications* GENERAL FEATURES FREQUENCY RANGE IMPEDANCE RETURN LOSS COUPLING FACTOR DIRECTIVITY MAX MEAN POWER OPERATING TEMPERATURE RANGE CONNECTORS PROBE CONNECTORS WEIGHT PRESSURIZATION * MATERIALS - External body - Inner conductor - Insulator EXTERNAL FINISHING

0.1 ÷ 860 MHz 50 ohm ≥ 32 dB See table below ≥ 40 dB See table below -40 ÷ +70° C See table below NF See table below Typical operating pressure 300 hPa (300 mBar) Nickel plated brass, polished brass Silver plated brass Teflon Painted Ral 7001

*only for waterproff and protection type

MAX MEAN POWER (kW) 300 200

100

6-1/8” RL 120 4-1/2”

50

20

3-1/8” 10

1-5/8”

5

7/8” 7/16

1

0.5

COAXIAL COMPONENTS

N

0.2 40

50

VHF-BI

100

200

FM

VHF-BIII

1000

500

(MHz)

UHF Specifications are subject to change without prior notice

116

STANDARD CONDITIONS: V.S.W.R. = 1.0 Ambient temperature 40°C Atmospheric Pressure, DryAir Inner Conductor Temperature 120°C


DIRECTIONAL COUPLERS

figure “1”

figure “2”

B

figure “3”

TYPE ADR-01/W ADR-02/P ADR-02/W ADR-02/U ADR-03/P ADR-03/W ADR-03/U ADR-04/P ADR-04/W ADR-04/U ADR-06/P ADR-06/W ADR-06/U ADR-07/W ADR-08/P ADR-08/W ADR-08/U

CONNECTORS

Nr PROBES

FIGURE

NF 7/8” EIA 7/8” EIA 7/8” Unfl. 1-5/8” EIA 1-5/8” EIA 1-5/8” Unfl. 3-1/8” EIA 3-1/8” EIA 3-1/8” Unfl. 6-1/8” EIA 6-1/8” EIA 6-1/8” Unfl. 7/16 F 4-1/2” EIA 4-1/2” EIA 4-1/2” Unfl.

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 1 3 1 1 3 2 2 3 2 2 3 1 2 2 3

C

DIMENSIONS A (mm)

B (mm)

C (mm)

(kg)

WATER PROOF

177 200 200 195.5 198 198 190.4 246 246 237 281 281 273 180 246 246 236.5

149 172 148 145 172 149 145 195 172 153.5 276 253 234 149 229 206 185.5

45 58 58 22.3 89 89 41.3 128 128 79.4 206 206 155.6 45 159 159 106

2.5 2.8 2.6 1.5 2.4 2.2 1.4 4.5 4 2.8 10 9.6 5.1 2.5 6 5.5 3.6

NO YES NO NO YES NO NO YES NO NO YES NO NO NO YES NO NO

WEIGHT

Note: F = female / M = male Specifications are subject to change without prior notice

117

PROTECTION NO YES NO NO YES NO NO YES NO NO YES NO NO NO YES NO NO

COUPLING FACTOR (dB) FM VHF UHF min/max min/max min/max -56/-51 -56/-51 -56/-51 -56/-51 -56/-51 -56/-51 -56/-51 -61/-56 -61/-56 -61/-56 -67/-62 -67/-62 -67/-62 -56/-51 -64/-59 -64/-59 -64/-59

-49/-45 -49/-45 -49/-45 -49/-45 -49/-45 -49/-45 -49/-45 -55/-51 -55/-51 -55/-51 -61/-57 -61/-57 -61/-57 -49/-45 -58/-54 -58/-54 -58/-54

-38/-35 -38/-35 -38/-35 -38/-35 -38/-35 -38/-35 -38/-35 -45/-42 -45/-42 -45/-42 -49/-46 -49/-46 -49/-46 -38/-35 -43/-46 -43/-46 -43/-46

COAXIAL COMPONENTS

A


FREQUENCY EQUALIZED DIRECTIONAL COUPLERS

FEATURES unflanged directional coupler low V.S.W.R and insertion losses only for indoor applications GENERAL FEATURES FREQUENCY RANGE

FM band 87.5 ÷ 108 MHz (EF) VHF band 174 ÷ 254 MHz (EV) UHF band 470 ÷ 860 MHz (EU) 50 ohm ≥ 30 dB See table below ≥ 30 dB ≤ ±0.15 dB See table below -10 ÷ +45° C See table below SMA F See table below No Aluminium Silver plated brass Teflon, rexolite Surtec 650

IMPEDANCE RETURN LOSS COUPLING FACTOR DIRECTIVITY FLATNESS MAX MEAN POWER OPERATING TEMPERATURE RANGE CONNECTORS PROBE CONNECTORS WEIGHT WATERPROOF MATERIALS - External body - Inner conductor - Insulator EXTERNAL FINISHING MAX MEAN POWER (kW) 300 200

100

6-1/8” RL 120 4-1/2”

50

20

3-1/8” 10

1-5/8”

5

7/8” 7/16

1

0.5

COAXIAL COMPONENTS

N

0.2 40

50

VHF-BI

100

200

FM

VHF-BIII

1000

500

(MHz)

UHF Specifications are subject to change without prior notice

118

STANDARD CONDITIONS: V.S.W.R. = 1.0 Ambient temperature 40°C Atmospheric Pressure, DryAir Inner Conductor Temperature 120°C


FREQUENCY EQUALIZED DIRECTIONAL COUPLERS

figure “3” figure “2”

figure “1”

TYPE ADR-01/EF/n/AA ADR-01/EF/n/AA ADR-01/EF/n/AA1 ADR-01/EF/n/AA1 ADR-01/EF/n/BB ADR-01/EF/n/BB ADR-01/EF/n/BB1 ADR-01/EF/n/BB1 ADR-01/EF/n/CC ADR-01/EF/n/CC ADR-01/EF/n/CC1 ADR-01/EF/n/CC1 ADR-02/EF/n/DD ADR-02/EF/n/DD ADR-02/EF/n/DD1 ADR-02/EF/n/DD1 ADR-03/EF/n/EE ADR-03/EF/n/EE1 ADR-04/EF/n/FF ADR-04/EF/n/FF1

CONNECTORS NF - NF NF - NF NF - NM NF - NM 7/16 F - 7/16 F 7/16 F - 7/16 F 7/16 F - 7/16 M 7/16 F - 7/16 M 7/8 Unfl F - 7/8 Unfl F 7/8 Unfl F - 7/8 Unfl F 7/8 Unfl F - 7/8 Unfl M 7/8 Unfl F - 7/8 Unfl M 1-5/8 Unfl F - 1-5/8 Unfl F 1-5/8 Unfl F - 1-5/8 Unfl F 1-5/8 Unfl F - 1-5/8 Unfl M 1-5/8 Unfl F - 1-5/8 Unfl M 3-1/8 Unfl F - 3-1/8 Unfl F 3-1/8 Unfl F - 3-1/8 Unfl M 4-1/2 Unfl F - 4-1/2 Unfl F 4-1/2 Unfl F - 4-1/2 Unfl M

Nr PROBES

FIGURE

1/2 3/4 1/2 3/4 1/2 3/4 1/2 3/4 1/2 3/4 1/2 3/4 1/2 3/4 1/2 3/4 1/4 1/4 1/4 1/4

1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 3 3 3 3

A (mm)

B (mm)

C (mm)

WEIGHT kg (max)

105 165 123 183 102 162 111 171 138 198 128 187 170 230 190 250 155 155 184 184

104 104 104 104 104 104 104 104 104 104 104 104 119.5 119.5 119.5 119.5 110 110 151.5 151.5

50 50 50 50 50 50 50 50 50 50 50 50 60 60 60 60 177.4 172 184 173.6

0.60 1.13 0.65 1.18 0.68 1.21 0.72 1.25 0.59 1.12 0.62 1.15 0.93 1.69 1.06 1.82 2.37 2.17 2.90 3.02

DIMENSIONS (max)

Note: n = nr probes F = female / M = male (*) ambient temperature 40°C Specifications are subject to change without prior notice

119

MAX POWER kW (*)

COUPLING FACTOR (dB) min/max

0.75 0.75 0.75 0.75 4.1 4.1 4.1 4.1 7.3 7.3 7.3 7.3 17 17 17 17 50 50 75 75

-50/-70 -50/-70 -50/-70 -50/-70 -50/-70 -50/-70 -50/-70 -50/-70 -50/-70 -50/-70 -50/-70 -50/-70 -55/-75 -55/-75 -55/-75 -55/-75 -60/-80 -60/-80 -65/-85 -65/-85

COAXIAL COMPONENTS

FM Band


FREQUENCY EQUALIZED DIRECTIONAL COUPLERS figure “3” figure “2”

figure “1”

VHF Band TYPE

COAXIAL COMPONENTS

ADR-01/EV/n/AA ADR-01/EV/n/AA ADR-01/EV/n/AA1 ADR-01/EV/n/AA1 ADR-01/EV/n/BB ADR-01/EV/n/BB ADR-01/EV/n/BB1 ADR-01/EV/n/BB1 ADR-01/EV/n/CC ADR-01/EV/n/CC ADR-01/EV/n/CC1 ADR-01/EV/n/CC1 ADR-02/EV/n/DD ADR-02/EV/n/DD ADR-02/EV/n/DD1 ADR-02/EV/n/DD1 ADR-03/EV/n/EE ADR-03/EV/n/EE1 ADR-04/EV/n/FF ADR-04/EV/n/FF1

CONNECTORS NF - NF NF - NF NF - NM NF - NM 7/16 F - 7/16 F 7/16 F - 7/16 F 7/16 F - 7/16 M 7/16 F - 7/16 M 7/8 Unfl F - 7/8 Unfl F 7/8 Unfl F - 7/8 Unfl F 7/8 Unfl F - 7/8 Unfl M 7/8 Unfl F - 7/8 Unfl M 1-5/8 Unfl F - 1-5/8 Unfl F 1-5/8 Unfl F - 1-5/8 Unfl F 1-5/8 Unfl F - 1-5/8 Unfl M 1-5/8 Unfl F - 1-5/8 Unfl M 3-1/8 Unfl F - 3-1/8 Unfl F 3-1/8 Unfl F - 3-1/8 Unfl M 4-1/2 Unfl F - 4-1/2 Unfl F 4-1/2 Unfl F - 4-1/2 Unfl M

Nr PROBES

FIGURE

1/2 3/4 1/2 3/4 1/2 3/4 1/2 3/4 1/2 3/4 1/2 3/4 1/2 3/4 1/2 3/4 1/4 1/4 1/4 1/4

1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 3 3 3 3

A (mm)

B (mm)

C (mm)

WEIGHT kg (max)

105 165 123 183 102 162 111 171 138 198 128 187 170 230 190 250 155 155 184 184

104 104 104 104 104 104 104 104 104 104 104 104 119.5 119.5 119.5 119.5 110 110 151.5 151.5

50 50 50 50 50 50 50 50 50 50 50 50 60 60 60 60 177.4 172 184 173.6

0.60 1.13 0.65 1.18 0.68 1.21 0.72 1.25 0.59 1.12 0.62 1.15 0.93 1.69 1.06 1.82 2.37 2.17 2.90 3.02

DIMENSIONS (max)

Note: n = nr probes F = female / M = male (*) ambient temperature 40°C Specifications are subject to change without prior notice

120

MAX POWER kW (*)

COUPLING FACTOR (dB) min/max

0.52 0.52 0.52 0.52 2.8 2.8 2.8 2.8 5 5 5 5 11.6 11.6 11.6 11.6 33 33 52 52

-45/-65 -45/-65 -45/-65 -45/-65 -45/-65 -45/-65 -45/-65 -45/-65 -45/-65 -45/-65 -45/-65 -45/-65 -50/-70 -50/-70 -50/-70 -50/-70 -55/-75 -55/-75 -60/-80 -60/-80


FREQUENCY EQUALIZED DIRECTIONAL COUPLERS figure “3” figure “2”

figure “1”

TYPE ADR-01/EU/n/AA ADR-01/EU/n/AA ADR-01/EU/n/AA1 ADR-01/EU/n/AA1 ADR-01/EU/n/BB ADR-01/EU/n/BB ADR-01/EU/n/BB1 ADR-01/EU/n/BB1 ADR-01/EU/n/CC ADR-01/EU/n/CC ADR-01/EU/n/CC1 ADR-01/EU/n/CC1 ADR-02/EU/n/DD ADR-02/EU/n/DD ADR-02/EU/n/DD1 ADR-02/EU/n/DD1 ADR-03/EU/n/EE ADR-03/EU/n/EE1 ADR-04/EU/n/FF ADR-04/EU/n/FF1

CONNECTORS NF - NF NF - NF NF - NM NF - NM 7/16 F - 7/16 F 7/16 F - 7/16 F 7/16 F - 7/16 M 7/16 F - 7/16 M 7/8 Unfl F - 7/8 Unfl F 7/8 Unfl F - 7/8 Unfl F 7/8 Unfl F - 7/8 Unfl M 7/8 Unfl F - 7/8 Unfl M 1-5/8 Unfl F - 1-5/8 Unfl F 1-5/8 Unfl F - 1-5/8 Unfl F 1-5/8 Unfl F - 1-5/8 Unfl M 1-5/8 Unfl F - 1-5/8 Unfl M 3-1/8 Unfl F - 3-1/8 Unfl F 3-1/8 Unfl F - 3-1/8 Unfl M 4-1/2 Unfl F - 4-1/2 Unfl F 4-1/2 Unfl F - 4-1/2 Unfl M

Nr PROBES

FIGURE

1/2 3/4 1/2 3/4 1/2 3/4 1/2 3/4 1/2 3/4 1/2 3/4 1/2 3/4 1/2 3/4 1/4 1/4 1/4 1/4

1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 3 3 3 3

A (mm)

B (mm)

C (mm)

WEIGHT kg (max)

105 165 123 183 102 162 111 171 138 198 128 187 170 230 190 250 155 155 184 184

104 104 104 104 104 104 104 104 104 104 104 104 119.5 119.5 119.5 119.5 110 110 151.5 151.5

50 50 50 50 50 50 50 50 50 50 50 50 60 60 60 60 177.4 172 184 173.6

0.60 1.13 0.65 1.18 0.68 1.21 0.72 1.25 0.59 1.12 0.62 1.15 0.93 1.69 1.06 1.82 2.37 2.17 2.90 3.02

DIMENSIONS (max)

Note: n = nr probes F = female / M = male (*) ambient temperature 40°C Specifications are subject to change without prior notice

121

DTV MAX POWER kW (*)

ATV MAX POWER kW (*)

COUPLING FACTOR (dB) min/max

0.26 0.26 0.26 0.26 1.4 1.4 1.4 1.4 2.5 2.5 2.5 2.5 6.0 6.0 6.0 6.0 20 20 30 30

0.39 0.39 0.39 0.39 2.1 2.1 2.1 2.1 3.7 3.7 3.7 3.7 9.0 9.0 9.0 9.0 30 30 45 45

-35/-55 -35/-55 -35/-55 -35/-55 -35/-55 -35/-55 -35/-55 -35/-55 -35/-55 -35/-55 -35/-55 -35/-55 -40/-60 -40/-60 -40/-60 -40/-60 -45/-65 -45/-65 -50/-70 -50/-70 COAXIAL COMPONENTS

UHF Band


COAXIAL ELBOWS

FEATURES flanged / unflanged coaxial elbows low insertion losses low V.S.W.R indoor / outdoor applications* GENERAL FEATURES FREQUENCY RANGE IMPEDANCE RETURN LOSS MAX MEAN POWER OPERATING TEMPERATURE RANGE CONNECTORS WEIGHT PRESSURIZATION * MATERIALS - External body - Inner conductor - Insulator EXTERNAL FINISHING

0.1 ÷ 860 MHz ** 50 ohm ≥ 32 dB See table below -40 ÷ +70° C See table below See table below Typical operating pressure 300hPa (300mBar) Polished copper, polished brass, Aluminium Silver plated brass Teflon Painted Ral 7001, Nickel plating, Passivation SURTEC 650

* only for flanged types ** up to 790 MHz for 6-1/8”

MAX MEAN POWER (kW) 300 200

100

6-1/8” RL 120 4-1/2”

50

20

3-1/8” 10

1-5/8”

5

7/8” 7/16

1

0.5

COAXIAL COMPONENTS

N

0.2 40

50

VHF-BI

100

200

FM

VHF-BIII

1000

500

(MHz)

UHF Specifications are subject to change without prior notice

122

STANDARD CONDITIONS: V.S.W.R. = 1.0 Ambient temperature 40°C Atmospheric Pressure, DryAir Inner Conductor Temperature 120°C


COAXIAL ELBOWS

figure “1”

figure “2”

figure “3”

GMT-01 GMT-01/CP* GMT-03 GMT-04 GMT-05 GMT-06 GMT-07 GMT-10 GMT-17 GMT-11 GMT-12 GMT-15 GMT-16 GMT-18

CONNECTORS 7/8” EIA 7/8” EIA 1-5/8” EIA M-F 1-5/8” EIA 3-1/8” EIA 4-1/8” FL 6-1/8” EIA 4-1/2” EIA 7/8” Unfl. M 1-5/8” Unfl. M 3-1/8” Unfl. M 6-1/8” Unfl. M 4-1/2” Unfl. M RL 120 Unfl. M

DIMENSIONS

FIGURE 2 4 3 2 2 2 2 2 1 1 1 1 1 1

WEIGHT

A (mm)

B (mm)

C (mm)

D (mm)

(kg)

55 55 65 65 85 100 130 100 18.7 38.4 59.5 89.5 79.5 85

84 84 110 110 149 180 233 179.5 35 60 89 140 109 115

58 58 89 89 128 160 206 159 32 48 90 170 120 130

149 62.3 98.4 149 256.5 184.3 218

0.62 0.72 1.4 1.3 2.9 4 9.1 4.4 0.12 0.4 2.1 6.7 3.5 3.4

figure “4”

Note: F = female / M = male * with Capacitive Probe Specifications are subject to change without prior notice

123

COAXIAL COMPONENTS

TYPE


COAXIAL ADAPTORS

FEATURES flanged / unflanged coaxial elbows low insertion losses low V.S.W.R indoor / outdoor applications GENERAL FEATURES FREQUENCY RANGE IMPEDANCE RETURN LOSS MAX MEAN POWER OPERATING TEMPERATURE RANGE CONNECTORS WEIGHT PRESSURIZATION *

0.1 ÷ 860 MHz 50 ohm ≥ 32 dB See table below -40 ÷ +70° C See table See table Typical operating pressure 300 hPa (300 mbar) Polished copper, polished brass Silver plated brass Teflon Painted Ral 7001, Nickel plating

MATERIALS

- External body - Inner conductor - Insulator EXTERNAL FINISHING * only for flanged types

MAX MEAN POWER (kW) 300 200

100

6-1/8” RL 120 4-1/2”

50

20

3-1/8” 10

1-5/8”

5

7/8” 7/16

1

0.5

N

0.2

COAXIAL COMPONENTS

40

50

VHF-BI

100

200

FM

VHF-BIII

1000

500

(MHz)

UHF

Note: Power handling is limited by the smallest size Specifications are subject to change without prior notice

124

STANDARD CONDITIONS: V.S.W.R. = 1.0 Ambient temperature 40°C Atmospheric Pressure, DryAir Inner Conductor Temperature 120°C


COAXIAL ADAPTORS

figure “1”

figure “2”

FLANGED COAXIAL ADAPTORS

TRS-01 TRS-02 TRS-03 TRS-04 TRS-05 TRS-06 TRS-07 TRS-08 TRS-11 TRS-12 TRS-13 TRS-14 TRS-15 TRS-16 TRS-17 TRS-19 TRS-22 TRS-26 TRS-27 TRS-36 TRS-37 TRS-39 TRS-40 TRS-41 TRS-42 TRS-44 TRS-45 TRS-46

CONNECTORS 7/16 F 7/16 M 7/8” EIA M 7/8” EIA M 7/8” EIA 7/8” EIA 7/8” EIA 7/8” EIA 1-5/8” EIA 1-5/8” EIA 1-5/8” EIA 1-5/8” EIA 1-5/8” EIA 1-5/8” EIA M 3-1/8” EIA 3-1/8” EIA 6-1/8” EIA 3-1/8” EIA 4-1/2” EIA 6-1/8” EIA 4-1/2” EIA 4-1/2” EIA 1-5/8” EIA M 6-1/8” EIA 4-1/2” EIA 6-1/8” EIA 3-1/8” EIA 1-5/8” EIA

FIGURE

NF NF NF NM NF NM 7/16 F 7/16 M NF NM 7/16 F 7/16 M 7/8” EIA 7/8” EIA 1-5/8” EIA NF 3-1/8” EIA 7/8” EIA 4-1/8” FL M NF 3-1/8” EIA NF 7/8” EIA 4-1/2” EIA 3-1/8” EIA 7/16 F 7/16 F Dezifix D

6 6 5 5 4 4 3 3 4 4 4 4 1 2 1 4 1 1 2 4 1 4 2 1 1 4 4 3

DIMENSIONS

WEIGHT

A (mm)

B (mm)

(kg)

45 59 42.5 39 83.5 80 63.5 66 123.5 120 111 125 83.5 60 110 162 150 120 65 207 95 150 21 150 117 194.5 149.5 138.5

32 35 58 58 58 58 58 58 89 89 89 89 89 89 128 128 150 128 159 206 159 159 89 206 159 206 128 98

0.14 0.19 0.3 0.32 0.3 0.36 0.2 0.28 1 1 1 1 0.77 0.85 1.5 3 3.8 1.3 2.6 6.4 3 3.5 0.65 4.5 2.5 4.8 3 2.6

Note: F = female / M = male Specifications are subject to change without prior notice

125

figure “3”

figure “4”

figure “5”

figure “6”

COAXIAL COMPONENTS

TYPE


COAXIAL ADAPTORS

figure “7”

figure “8”

UNFLANGED COAXIAL ADAPTORS

COAXIAL COMPONENTS

TRS-11/U TRS-12/U TRS-13/U TRS-14/U TRS-16/U TRS-17/U TRS-19/U TRS-22/U TRS-26/U TRS-27/U TRS-38/U TRS-39/U TRS-40/U TRS-41/U TRS-42/U TRS-43/U TRS-45/U TRS-47/U TRS-48/U TRS-50/U TRS-51/U TRS-52/U TRS-56/U

CONNECTORS 1-5/8” Unfl. M 1-5/8” Unfl. M 1-5/8” Unfl. M 1-5/8” Unfl. M 1-5/8” Unfl. M 3-1/8” Unfl. M 3-1/8” Unfl. M 6-1/8” Unfl. M 3-1/8” Unfl. M 4-1/2” Unfl. M 6-1/8” Unfl. M 4-1/2” Unfl. M 1-5/8” Unfl. M 6-1/8” Unfl. M 4-1/2” Unfl. M 4-1/2” Unfl. M 3-1/8” Unfl. M 4-1/2” Unfl. M 4-1/2” Unfl. M 4-1/2” Unfl. M RL 120 Unfl. M 4-1/2” Unfl. M 6-1/8” Unfl. M

FIGURE

NF NM 7/16 F 7/16 M 7/8” EIA 1-5/8” Unfl. M NF 3-1/8” Unfl. M 7/8” EIA 4-1/8 FL 1-5/8” Unfl. M NF 7/8” Unfl. 4-1/2” Unfl. M 3-1/8” Unfl. M 4-1/8” Unfl. M 7/16 F 7/8” EIA 4-1/2” EIA 7/16 F NF 1-5/8” Unfl. M 3-1/8” Unfl. F

9 9 9 9 8 7 9 7 8 8 7 9 10 7 7 7 9 8 8 9 9 7 10

DIMENSIONS

WEIGHT

A (mm)

B (mm)

(kg)

103 99.5 56.4 104 115 124.5 104 177 101 45 152.5 106 90 153 145 119 94 103 149 96 115 127.2 185.6

57.5 57.5 45 57.5 58 100 100 177 100 159 177 127 58 177 127 127 100 127 159 127 145 127 177

0.3 0.33 0.25 0.35 0.5 1 1 3.5 1 1.2 3 0.75 0.15 3.3 1.8 1.8 0.5 1.4 2 0.8 1.2 0.77 3.4

Note: F = female / M = male Specifications are subject to change without prior notice

126

figure “9”

figure “10”

B

TYPE

A


UHF 3dB COUPLERS

FEATURES flanged / unflanged 3dB couplers low insertion losses low V.S.W.R indoor applications multisection design GENERAL FEATURES FREQUENCY RANGE IMPEDANCE RETURN LOSS COUPLING standard layout multisection (M) layout ISOLATION PHASE DIFFERENCE BETWEEN THE OUTPUTS MAX MEAN POWER * OPERATING TEMPERATURE RANGE CONNECTORS WEIGHT PRESSURIZATION MATERIALS - External body - Inner conductor

470 ÷ 862 MHz 50 ohm ≥ 30 dB 3 ± 0.3 dB 3 ± 0.1 dB ≥ 30 dB 90° ± 1° See table below -40 ÷ +70° C See table below See table below No Brass and aluminium Silver plated brass, polished brass silver plated aluminium deoxidized aluminium Teflon Painted Ral 9005, Surtec 650

- Insulator EXTERNAL FINISHING

figure “1”

* at 860 MHz, V.S.W.R. =1.0, Atmospheric Pressure, Dry Air, ambient temperature 40°C, Inner conductor temperature 120°C

ITV-02XM ITV-03X ITV-03XM ITV-04XM ITV-05XM ITV-06XM

NF NF 7/16 F NF 7/16 F 7/8” Unfl. F 7/8” Unfl. F 1-5/8” Unfl. F 1-5/8” Unfl. F 3-1/8” Unfl. F 3-1/8” Unfl. F 4-1/2” Unfl. F RL 120 Unfl. F

FIGURE 1 1 1 2 2 2 1 1 2 2 2 2 2

DIMENSIONS A (mm)

B (mm)

C (mm)

D (mm)

112 134 134 320 320 320 151 151 320 320 320 320 320

138 172 172 360 360 360 222 222 380 380 465 480 480

78 94 97 109 111 139 177 177 211 244 280 321 309

30 80 80 49 49 49 96 96 78 78 116 196 196

WEIGHT MAX MEAN (kg) POWER (kW) 0.5 1.2 1.2 2.2 2.2 2.2 3 3.2 5 5.2 7.5 15 15.5

0.2 0.2 1.4 0.2 1.4 2.5 2.5 5 5 10 20 30 42

Note: F = female Specifications are subject to change without prior notice

127

figure “2”

A B

D

COAXIAL COMPONENTS

ITV-01X ITV-02X

CONNECTORS

C

TYPE


CABLE TEST SECTIONS

FEATURES direct antenna system VSWR testing quick and accurate measurements low V.S.W.R suitable for outdoor applications

GENERAL FEATURES FREQUENCY RANGE IMPEDANCE RETURN LOSS MAX MEAN POWER OPERATING TEMPERATURE RANGE CONNECTORS WEIGHT PRESSURIZATION * MATERIALS - External body - Inner conductor - Insulator EXTERNAL FINISHING

See table 50 ohm ≥ 32 dB See table below -40 ÷ +70° C See table below See table below Typical operating pressure 300 hPa (300 mBar) Polished copper, polished brass Silver plated brass Teflon Painted Ral 7001

MAX MEAN POWER (kW) 300 200

100

6-1/8” RL 120 4-1/2”

50

20

3-1/8” 10

1-5/8”

5

7/8” 7/16

1

0.5

COAXIAL COMPONENTS

N

0.2 40

50

VHF-BI

100

200

FM

VHF-BIII

1000

500

(MHz)

UHF Specifications are subject to change without prior notice

128

STANDARD CONDITIONS: V.S.W.R. = 1.0 Ambient temperature 40°C Atmospheric Pressure, DryAir Inner Conductor Temperature 120°C


CABLE TEST SECTIONS

figure “1”

CONNECTORS

PCM-04

up to 860

1-5/8” EIA

PCM-14

up to 860

PCM-24 PCM-26

DIMENSIONS

FIGURE

WEIGHT

A (mm)

B (mm)

C (mm)

(kg)

1

300

145

89

7

3-1/8” EIA

1

350

184

128

10

up to 860

4-1/2” EIA

1

430

208

159

15

up to 860

6-1/8” EIA

1

520

245

206

26.5

Specifications are subject to change without prior notice

129

INSERT SECTION 1-5/8” - NF 1-5/8” - 7/16 F 3-1/8” - NF 3-1/8” - 7/16 F 4-1/2” - NF 4-1/2” - 7/16 F 6-1/8” - NF 6-1/8” - 7/16 F

COAXIAL COMPONENTS

FREQUENCY RANGE (MHz)

TYPE


COAXIAL ACCESSORIES

FEATURES flanged / unflanged coaxial accessories low insertion losses low V.S.W.R indoor / outdoor applications

GENERAL FEATURES FREQUENCY RANGE IMPEDANCE RETURN LOSS MAX MEAN POWER OPERATING TEMPERATURE RANGE CONNECTORS WEIGHT MATERIALS - External body - Inner conductor - Insulator EXTERNAL FINISHING

0.1 ÷ 860 MHz 50 ohm ≥ 32 dB See table below -40 ÷ +70° C See table See table Polished copper, polished brass, Aluminium Silver plated brass Teflon Nickel plating, Passivation SURTEC 650

MAX MEAN POWER (kW) 300 200

100

6-1/8” RL 120 4-1/2”

50

20

3-1/8” 10

1-5/8”

5

7/8” 7/16

1

0.5

COAXIAL COMPONENTS

N

0.2 40

50

VHF-BI

100

200

FM

VHF-BIII

1000

500

(MHz)

UHF Specifications are subject to change without prior notice

130

STANDARD CONDITIONS: V.S.W.R. = 1.0 Ambient temperature 40°C Atmospheric Pressure, DryAir Inner Conductor Temperature 120°C


COAXIAL ACCESSORIES

BULLETS DIMENSIONS TYPE

CONNECTORS

INN-01 INN-02 INN-03 INN-07 INN-12 INN-05

7/8” 1-5/8” 3-1/8” 4-1/2” RL 120 6-1/8”

WEIGHT

A (mm)

B (mm)

(kg)

59.8 78.4 100 10 118 125

20.65 41.75 81.2 105.3 123.8 154

0.02 0.1 0.3 0.6 0.9 1.3

GAS BARRIERS DIMENSIONS TYPE

CONNECTORS

BAR-01 BAR-02 BAR-03 BAR-04 BAR-05

7/8” EIA M 1-5/8”EIA M 3-1/8”EIA M 4-1/2”EIA M 6-1/8”EIA M

WEIGHT

A (mm)

B (mm)

(kg)

30 30 35 40 40

58 89 128 159 206

0.6 1.3 2.7 4.3 8.5

CLAMP FLANGE DIMENSIONS TYPE

CONNECTORS

FLN-33 FLN-01 FLN-02 FLN-27 FLN-34 FLN-10

7/8” EIA 1-5/8” EIA 3-1/8” EIA 4-1/2” EIA RL 120 6-1/8” EIA

WEIGHT

A (mm)

B (mm)

(kg)

29 41 42 35.5 53.5 64

58 89 128 159 180 206

0.2 0.5 0.9 1.2 0.6 2

STRAIGHT COUPLINGS CONNECTORS

FLN-32 FLN-03 FLN-04 FLN-09 FLN-28 FLN-35

7/8” Unfl. M 1-5/8” Unfl. M 3-1/8” Unfl. M 6-1/8” Unfl. M 4-1/2” Unfl. M RL 120 Unfl. M

WEIGHT

A (mm)

B (mm)

(kg)

59.8 78.4 100 95 71.6 70

30 60 100 177 127 142

0.15 0.3 0.81 2.2 0.9 1.1

Note: M = male Specifications are subject to change without prior notice

131

COAXIAL COMPONENTS

DIMENSIONS TYPE


notes

SpeciďŹ cations are subject to change without prior notice

132


notes

SpeciďŹ cations are subject to change without prior notice

133


notes

SpeciďŹ cations are subject to change without prior notice

134



Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.