Shubham inc wastewater treatment company in india gujarat

Page 1

OOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOO

A Brief about Reverse Osmosis & Ultrafiltration !!


Reverse

Osmosis & Ultra Filtration System

OOOO OOOOOOOOO OOOOOOOOOOOOOOOOOO OOOOOOOOO OOOOOOOOO

TABLE OF CONTENT

About us .............................................................................………...........3

Product Portfolio ..................................................................................4

Osmosis………………………………………………………………………………………….…….7

Reverse Osmosis Definition…………………………………………………….………8

How does it work …………………………………………………… ……………………….8

RO membranes……………………………………………………………………………......9

Membrane Structure………………………………………………….......................10

Types of Membrane…………………………………………………........................11

Parameters aftects RO…………………………………………………………………13 RO 13

Production rate V/s Feed Water Conditions…………......................14

Capable of Removing……………………………………………………………………..15

Rejection ranges of contaminants ……………………………………………16

RO Treated water…………………………………………………………………............17

yp Membrane Types………………………………………………………………………..18-19

| 2


Reverse

Osmosis & Ultra Filtration System

OOOO OOOOOOOOO OOOOOOOOOOOOOOOOOO OOOOOOOOO OOOOOOOOO

TABLE OF CONTENT

Ultrafiltration .............................................................................…………..21

Difference Between RO & UF ...............................................................22

Advantages of Ultrafiltration…………………..……………………………………….24

Ultrafiltration Application …………………………………………………………….……25

UF as Pre & Post Treatment ………………………………… ……………………….26

MF to RO …………….……………………………………………………………………………......27

Configuration fi i off UF…………………………………………………..................................28

UF Flow Pattern …………………………………………………........................................29

Design Guide lines for UF………………………………………………………………………30

| 3


A role of Shubham in Saving Precious water ……..

Shubham is in the business of making this planet water secure………..

Shubham Inc. is the leading EPC contractor of Water and Sewage Water Treatment Plants. We use the bestin-class technology and cutting-edge tools to foster high-quality, sustainable, community-level water supply projects.

We design, engineer, and deliver the most innovative, cost-effective solutions for managing your most challenging water woes!

| 4


Product Portfolio | 5

Product Portfolio Membrane and separation Reverse Osmosis Plant UF Plants Media Filters Activated Carbon Filters Dual Media Filters Multigrade Filters Pressure Sand Filters Side Stream Filters ION exchange DM Plants Softening Plants Mixed Bed units

Waste Water Treatment

Swimming Pool

Septic Tanks

Operation & Maintenance

Sewage Treatment Plants [ Civil & Modular ] Bio Accelerator 360°™ Electra Rapid™ Bio Memclean™ Bio Synthesis Effluent Treatment Plant (ETP) Grey G W Water t Treatment T t t (GWT) Laundry Water treatment


Osmosis| 6  Osmosis is a natural phenomenon that provides water to all animal and vegetable cells to support life  Water moves from a high concentration of water (less sugar/salt dissolved in it) to a low concentration of water (more salt/sugar dissolved in it) across a semi-permeable membrane  This means that water can cross a selectively permeable membrane from a dilute solution (less dissolved in it) to a concentrated solution (more dissolved in it))


Osmosis | 7

Net et Movement o e e t of o Water ate Mol o A se semi-permeable pe eab e membrane e b a e is s a membrane e b a e which c will allow only certain molecules or ions to pass through  Osmosis is very y important p in biology gy as it p provides the p primary y means by y which water is transported in and out of cellsecules ecules


Reverse Osmosis | 8

 RO is a form of filtration using osmosis in reverse  Water passes from a more concentrated solution to a less concentrated solution p this a force or p pressure MUST  To accomplish be applied

 RO is used to remove dissolved solids from water but it can also improve taste, odor & color of water  RO membranes have the capability to remove particles as small as ions i.e. magnesium ions or sodium ions  RO membrane b will ill reject j most compounds d based b d largely l l on size i  Dissolved ions, such as salts, carry an electric charge and will also be rejected by membrane


How does it work ? |

 Feed water flows into RO unit with the force of line pressure

 Water is forced through membrane by cross flow filtration  Cross C fl flow filtration fil i is i most commonly l used d in i RO as it i allows ll membrane to continually clean itself  Membrane then either rejects or repels contaminants  Two exit streams generated: waste & product stream  Waste stream consists of: A concentrate (reject) stream which carries i contaminants i ((compounds d too large l to pass through h h membrane)  Permeate stream consists of: Product water which has been forced through the membrane & is virtually free of TDS

PNID or Process flow chart

9


RO Membrane |

10


| 11

FEED WATER

Main flow of impure water to be treated

PRODUCT WATER

Portion of feed water which passes through membrane as permeate

REJECT WATER:

Portion of feed water which did not pass through membrane; carries impurities to drain

MODULE

Combination of spiral round membrane element & pressure vessel


Spiral Wound Membrane |

Thin Film Composite Membrane (TFC) 

RO membrane is a method of fine filtration but much smaller

Membrane consists of tiny pores which are approximately 0.0005 microns in size

THEREFORE reverse osmosis i membranes b are capable bl off rejecting j ti contaminants t i t as smallll as 0.0001 to 0.00001 microns

12


RO Membrane | 13

 Membrane is the work work--horse of an reverse osmosis system

 When h choosing h i an RO system you must do d so wisely i l – taking ki iinto account water quality li iis very important membranes:  Three main types of membranes: CTA membrane:: Cellulose acetate/triacetate blend  Provides lowest cost per gallon of water  Resists chlorine but has a lower flow rate limit in applications of high water consumptio TFC membrane:: Thin film/thin layer composite  Can handle high flow, has a high rejection rate & can handle high water consumption  Cannot handle chlorine concentrations; water must be carbon pre pre--filtered


Parameters that affect RO |

Water Temperature: Temperature: RO system ratings are based on 770F/ 250C water temperature

i.e. : RO system rated at 20 GPD (gallons per day) at 340F/10C will only produce 6 GPD

Feed Water Pressure: Pressure: A lack in water pressure (less than 40 PSI) will reduce product p water; this can be helped p with the aid of a booster pump p p

Contaminants in Feed Water: Water: Large particles, iron concentration or high levels of hardness in feed water can cause clogging of the membrane Clogging of the membrane can decrease its life

Microorganisms:: RO membranes can filter out bacteria, depending on the Microorganisms bacteria size, however this may cause fouling of the membrane as bacteria can begin to grow through pores of membrane causing

BACTERIA CREEP – RO systems should not be installed on nonnon-potable water

14


RO Production Rate vs. Feed Water Conditions | Feedwater Temp TDS 째F ppm 40

45

50

50 250 500 750 1000 1500 2000 50 250 500 750 1000 1500 2000 50 250 500 750 1000 1500 2000

Feed Pressure (psi) 30

40

50

60

70

80

7.06 6.76 6 17 6.17 5.59 5.00 3.53 2 35 2.35 8.53 7.94 7.35 6.47 5.88 4.41 2.94 10.00 9 11 9.11 8.53 7.64 6.76 5.00 3.23

9.70 9.11 8 53 8.53 7.94 7.35 6.17 5 00 5.00 11.47 10.88 10.00 9.41 8.82 7.35 5.88 13.23 12 64 12.64 11.76 10.88 10.00 8.53 6.76

12.05 11.47 10 88 10.88 10.29 9.70 8.53 7 35 7.35 14.41 13.82 12.94 12.35 11.47 10.00 8.82 16.46 15 88 15.88 14.99 14.11 13.52 11.76 10.00

14.41 14.11 13 52 13.52 12.94 12.05 10.88 9 70 9.70 17.35 16.76 15.88 15.29 14.41 12.94 11.47 19.99 19 40 19.40 18.52 17.64 16.76 14.99 13.52

17.05 16.46 15 88 15.88 15.29 14.70 13.52 12 05 12.05 19.99 19.70 18.82 18.23 17.35 15.88 14.41 23.23 22 64 22.64 21.76 20.87 19.99 18.52 16.76

19.40 18.82 18 23 18.23 17.64 17.05 15.88 14 70 14.70 22.93 22.34 21.76 20.87 20.29 18.82 17.35 26.75 25 87 25.87 25.28 24.40 23.52 21.76 19.99

15


RO System Can is capable of removing …. | 16

 Dissolved solids = TDS (salts & minerals) – UP TO 2000 ppm  Most Heavy metals (lead, mercury, silver)  Most radioactive elements  RO systems may not be capable of removing nitrates to recommended levels


Typical Rejection Ranges of Contaminants |

17


RO Treated Water RO Treated Water | 18

RO systems will remove up to 97% (depending on parameters) of salts in water bringing it closer to a level of ‘pure pure water water’  The purer the water, the more aggressive it will be with materials it comes in contact with  THEREFORE RO can be slightly corrosive  It’s recommended NEVER to use copper piping on RO water


Membrane Types | 19

ED

Retained

Transported

Water, TSS, microbes uncharged molecules

MF Larger particles

Dissolved salts, Dissolved salts small small particles

UF

NF

RO

Larger molecules

Higher charged ions

almost everything

Small molecules and ions

Mono‐ valent ions, small small molecules

Very small uncharged molecules


Membrane Types | 20


Ultrafiltration


Ultrafiltration| 22

Primarily a concentration process p g energy gy is required q to force liquid q through g Pumping the membrane Relatively large size particles (MW 10000 – 40000<) are retained and concentrated Potential use in the recycling of metal containing alkaline cleaner wastes and paints (concentrate) Reduction of metals in industrial wastes


Ultrafiltration| 23

Does not change the chemistry of water. •For example to obtain potable water from surface water, which is chemically clean, but contains algea and bacteria, UF can be used. Same water quality with coagulation / flocculaltion  Removes turbidity •Same UF removes larger organics, colloids, bacteria while allowing most ions and small organics to permeate the porous structure. Larger pore size  Requires much lower differential operating pressure. pressure


Ultrafiltration|

Cross flow or transverse flow Any Any membrane configuration Use re-circulation for high TSS Operating O i pressures ~ 50 psii Uses back flush to loosen fouling Excellent pretreatment for RO or Post treatment for ED

24


Ultrafiltration|

UF can replace several conventional processes

25


Ultrafiltration – Applications | 26

Mayy be considered as p pre-treatment before R/O to p prevent clogging gg g of membranes. Applications in industrial wastes: Metal industry  Seperation of water-oil emulsions Automotive painting industry  to seperate d from dye f washing hi water t Pharmaceutical industry  Seperation of enzymes Food industry  Cheese waste


Ultrafiltration|

UF as Pre or Post Treatment ?

27


MF to RO |

28


UF Basic Configurations | 29


UF Flow Pattern | 30


Design Guidelines |

31


Locate Shubham |

OFFICE ADDRESS

HEAD OFFICE

501, Kalash – II, Nr. Jain Derasar, B/h. Navrangpura

A – 305, Shivalik Yash, Opp. Shastri Nagar

Post Office, Navrangpura,

BRTS, 132 Ft. Ring Road, Naranpura,

AHMEDABAD, Gujarat - INDIA.

AHMEDABAD, Gujarat – INDIA

VOICE +91 – 79 – 30086162 – 66 | FAX 91 – 79 –

VOICE +91 - 79 – 40086151 - 54 | FAX 91- 79 -

30086163

40086155 WORKS ADDRESS

Survey No. 481/2/3/1 , Gokul Hotel Lane, B/h Khodal Kathiyavadi Hotel, B/s One Shine Marbles, S. G, Highway Gota, AHMEDABAD, Gujarat – INDIA E mail - info@shubahmindia.com

32


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.