AUTO-ANSWER RING COUNT The auto-answer ring count is the number of rings the panel must count before answering an in-coming call. For Fax defeat to work the auto-answer ring count must be set to a number other than “0�. (typically 25 rings) P249E

Auto-answer Ring Count - Value 0-99 (0= Auto-answer disabled) - Default = 8

MAINS FAIL REPORTING DELAY This address (P319E) is used to set a timer that delays the reporting of Mains Failure to a Monitoring Station. If the mains voltage returns before the timer expires then no report is sent. P319E

Mains Failure Report Delay - Value 0-9999 Seconds (Default = 600)

Mains Fail Report 600

SETTING DIALER TEST REPORT PARAMETERS This option sets the days of the week and the time when an automatic test report is sent to a central monitoring station. PLEASE NOTE: If daylight saving adjustments are set (P408-P413) do not set the value at P402 to be a value between 1-3 am otherwise unwanted results will occur at the start & finish of daylight saving. Also, if a Domestic or Voice mode alarm is initiated but not reset or kissed off, when the test time comes around the dialer will attempt to report the event/s again. To prevent this from happening, turn off ALL days at P404E. P402E P404E

Automatic Test Report Hour/Minute - Value 0-2359 Automatic Test Report Day/s of Week - Value 1-7 (where 1 = Sunday, 2 = Monday, 3 = Tuesday, etc)

UPLOAD/DOWNLOAD SITE CODE NUMBER The upload/download site code number must be entered if the panel is set for auto-answer as this provides a security access level to the panel. The number can be up to 8 characters in length. Valid characters for this number are 0-9, B-F (refer to the chart on page 35). P505E

Site Code Number - 8 characters