CROW PW4-Inst&Prog_Guide_Rev_B_V1

Page 34

P412E Daylight Saving End Month - Value 1-12 - Default = 3 P413E Daylight Saving End Hour - Value 0-23 - Default = 3 When setting up a panel for the first time using daylight saving, you must ascertain whether daylight saving is currently ACTIVE. If it is you must enter in P414E then 1E to tell the panel that daylight saving is ON to sync the panel to daylight saving mode. If this is not done then when daylight saving finishes the panel will not adjust the clock. P414E Daylight Saving is Active (If LED #1 is On, Daylight Saving is currently active)

DLS Status 1

RESTORE FACTORY DEFAULTS This address (P620E) is used to return the panel back to factory default settings. P620E

Restore Factory Defaults

Reset All Done

RESTORING SELECTED DEFAULTS P621E P622E P623E P624E P625E

Restore Restore Restore Restore Restore

User Codes to Default only. all Program Addresses from 20-199 to Default all Program Addresses from 200-399 to Default all Program Addresses from 500-599 to Default all Radio & Pendant codes to Default

Reset Addr 21-199 Done

CLEAR ALARM MEMORY BUFFER This address (P626E) is used to clear the panels alarm memory buffer. P626E

Clear Alarm Memory Buffer

Clear Mem Buffer Done

WALK TEST MODE This address (P627E) is used to enable walk-test mode while in installer program mode. By pressing P627E at the keypad, the keypad buzzer will beep at 1 second intervals to indicate walk-test mode is active. By walking past all of the detectors connected to the system and activating them, the associated zone light will latch up at the keypad to allow verification that all zones are working properly. By pressing the “Program” or “Enter” buttons, walk-test mode can be terminated and normal programming resumed. Page 34


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.