SAP 10 CHANGES TO LIGHTING MATT DR LISA NALLY BLAKE FOUNDER, TECHNICAL SURVEY MANAGER, BOOKER SAVA
SAP 2012
As homes become more energy efficient due to insulation and air tightness, much like hot water algorithms, lighting will account for a higher percentage of energy use, therefore, the calculations for lighting need to be more sophisticated to accurately model the energy used. The calculations also need to be updated to allow for new lighting technologies.
Floor area
SAP 2012
SAP 2012
% LEL
Figure 1 – how lighting is calculated in SAP 2012
20
Daylight (windows)
SAP 2012
The current method of calculating the lighting requirement is quite simplistic. The floor area is used to calculate a
base energy requirement for lighting based on Tungsten lights. This energy is then adjusted for the proportion of low energy lights present, such as LED or CFL lights. This energy requirement is then adjusted for the daylighting which is based on the size, type and orientation of the windows present. In RdSAP, the window area is normally assumed with the orientation calculated using East. Currently SAP 2012 does not differentiate between different types of low energy lights or consider excessive or insufficient lighting.
SAP 2012
If you’re a regular reader of our technical bulletins, you’ll know that in our last two issues we looked at two of the methodological changes expected in the next version of SAP: hot water calculations and heating patterns. In this issue, we will take a closer look at another change to the methodology, which is the lighting calculations.
Lighting Requirements