ELECTRIC SYSTEM

Pegaso 650 I.E. 6.5.8 CHECKING THE COOLANT THERMISTOR OPERATION ◆ Remove the thermistor (1), see 5.5 (REMOVING THE

COOLANT THERMISTOR). ◆ Connect a tester (2) (set as an ohmmeter) to the ther-

mistor (1), as illustrated in the figure. ◆ Immerse the thermistor (1) in a container (3) holding

coolant. ◆ Immerse a thermometer (4) with a 0 to 150 °C (32 to

302 °F) range in the same container. ◆ Place the container on a burner (5) and slowly warm up

the liquid. ◆ Check the temperature indicated on the thermometer

(4) and the thermistor (1) value indicated by the tester. Make sure that the value varies according to the temperature, as indicated.

Water temperature (°C)

(°F)

Standard values (Ω) (± 10%)

0

32

5896

20

68

2500

40

104

1175

60

140

595.5

80

176

322.5

100

212

186.6

NOTE If when the temperature changes the standard values do not change or differ excessively from those indicated in the table, change the thermistor (1).

Release 00/2002-02