Sleep Lab Portrait

Page 1

IU Health Drawings: Lighting Power Fire Alarm


PANEL G

EXIT LS8

EXIT LS8

EXIT LS8

EX CIR

EX CIR

EX CIR

EX CIR

CLICK HERE FOR OUTSIDE FLOOD LIGHTS


FIXTURE TYPE EXIT MANUFACTURE: SURE-LITES DESCRIPTION: EXIT LIGHT PART # AP6 0 R W 120 LAMPS: LED WEB SITE: www.cooperindustries.com FACTORY REP: Specified Lighting 317-577-8100 SUPPLIER: FD Lawrence 317-549-1100 Warranty on Ballast 5 Years from Ship Date 01-02-2011

RETURN

SPECIFICATIONS


RETURN

DESCRIPTION

COOPER LIGHTING - SURE-LITES ®

The All Pro Series exit (AP60/70) is the most economical LED exit for general purpose applications. The durable, injection molded, thermoplastic material resists discoloration due to UV radiation and the energy efficient, low maintenance LED's provide bright illumination. All AP series exits offer universal configurations (single and double face) and have universal mounting capability (ceiling, wall, end).

Type

Catalog #

EXIT

BMH Sleep Lab

Project

Date

Comments Prepared by

EMD

S P E C I F I C AT I O N F E AT U R E S

construction to facilitate under 5-minute installation - Reinforcing ribs throughout to provide maximum strength - Molded-in wireways facilitate internal wire routing and connections - All components including battery and electronics are located inside the exit housing - Snap-out or snap-in chevron directional indicators have full 3/4" stroke - Universal exits can be field configured as single face or double face - Snap-fit canopy with mounting screws included with all exits - Exit can be ceiling, wall, or end mounted - Universal J-box mounting pattern

E l e c t ri c a l

- Dual Voltage Input 120/277 VAC, 60Hz - Solid-state Voltage Limited charger (AP70) - Brownout circuit (AP70) Test Switch/Power Indicator Light (AP70) B a tte r y ( A P 7 0 )

- Sealed Nickel Cadmium - Maintenance-free, Long-life - Full recharge time, 24 hrs. (max.) H o u s i n g C o n s t ru c t i o n

- All components are injectionmolded, color stable, high impact thermoplastic material - Designer white textured finish standard - Components are of snap-fit

L a m p Da t a

- AC LED: Long-life LED lamps provide uniform diffused illumination - DC: LED DC lamps (Brighter in emergency mode, AP70) Code Compliance

- UL 924 Listed - Damp Location - Life Safety NFPA 101 - NEC/OSHA - Most State and Local Codes Wa rra n t y

- Exit: 5-Year - Battery: 15-Year, pro-rata (Nickel Cadmium, AP70)

AP SERIES

4 5/16” [109.53mm]

T H E R M O P L AST I C E X I T AC O N LY S E L F P OW E R E D EMERGENCY LED LAMPS EXIT LIGHTING

4 3/4” [120.65mm]

7 1/2” [190mm]

11/16” [17.46.mm]

1 7/8” [47.62mm]

11 13/16” [300mm]

ORDERING INFORMATION

ENERGY D ATA

Family =AC only LED, All Pro Exit AP6=AC

Letter Colors =Red R=Red

AP7=Self-Powered with LED, All Pro Exit

G=Green

Face Options =Universal 0=Universal

Voltage __=120 / 277V Accessories

Housing Finish __=White

2

Protective Housing VS=Polycarbonate Vandal Shield3 WG=Wire Guard4

Battery __=Nickel Cadmium1

Notes:

1 Nickel Cadmium for AP70 only. 2 Order separately. 3 Choose polycarbonate vandal shield desired from accessories sheet. 4 Choose size of wire guard from accessories sheet.

Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes.

Sealed Nickel

ENERGY D ATA

Cadmium Battery

AC Only

LED Exits - Red

LED Exits - Red

Input Power:

Input Power:

120V = 2.3W

120V = 2.0W

277V = 2.3W

277V = 2.0W

Input Current (Max.):

Input Current (Max.):

120V = .02A

120V = .02A

277V = .01A

277V = .01A

Power Factor:

Power Factor:

120V = > .8

120V = > .8

277V = > .8

277V = > .8

LED Exits - Green

LED Exits - Green

Input Power:

Input Power:

120V = 2.0W

120V = 1.3W

277V = 2.0W

277V = 1.2W

Input Current (Max.):

Input Current (Max.):

120V = .02A

120V = .02A

277V = .01A

277V = .01A

Power Factor:

Power Factor:

120V = > .8

120V = > .7

277V = > .8

277V = > .7

ADX041751 pc 2010-08-18 11:37:42


T E C H N I C A L DATA

AP SERIES

RETURN

Lamps

Lens

S e a l e d N i cke l C a d m i u m B a tte r y ( A P 7 0 )

Self-Powered LED versions of the All Pro Emergency Series Exits use energy efficient, long life LEDs to provide uniform diffuse illumination of the exit face. Both the red and green LEDs require no maintenance and consume a total of 3.0 watts. The low operating costs and zero maintenance requirement makes LED lamps the wisest choice for exit signs today. Emergency illumination is provided by LED lamps.

Lenses for Self-powered versions of the All Pro Series Exits are made from durable impact resistant thermoplastic. All exit faces are designed with full 3/4” stroke snap-out or snapin chevron directional indicators to insure maximum visibility and compliance with the latest codes.

All Pro Emergency sealed nickel cadmium batteries are maintenance free with a life expectancy of 15 years. The sealed rechargeable nickel cadmium battery offers high discharge rates and stable performance over a wide range of temperatures. The specially designed resealable vent automatically controls cell pressure, assuring safety and reliability. This battery is best suited for harsh ambient temperatures because the electrolyte is not active in the electrochemical process.

H o u s i n g C o n s t ru c t i o n

Rugged, durable, injection molded thermoplastic materials are used throughout the All Pro Emergency Series Exits. All structural components are designed with reinforcing ribs to add additional rigidity and to maximize structural integrity. These materials are impact and scratch resistant, and they have been UV stabilized to resist discoloration due to age and ultraviolet radiation. All components are designed to be of snap-fit construction - no mechanical fasteners - to facilitate installation in under 5-minutes. Any components required for installation (wirenuts, wire leads, universal metal J-box bracket, etc.) are all included with each exit. The universal design of the All Pro Series Exits enables universal exits to be configured as single face or double face in the field. All Self-Powered All Pro Series Exits can be wall, ceiling, or end mounted; a rugged, snap-fit, low profile canopy with captive screws is included with every exit for ceiling and end mounting applications.

S o l i d - S t a te C h a rge r ( A P 7 0 )

Supplied with a 120/277 VAC, voltage regulated solid-state charger. Immediately upon restoration of AC current after a power failure, the charger provides a high charge rate. The charge circuit reacts to the condition of the battery and regulates the charging process in order to maintain peak battery capacity and maximize battery life. Solid-state construction recharges the battery following a power failure in accordance with UL 924.

Wa rra n t y

The All Pro Series exit signs are backed by a firm (5) year warranty against defects in material and workmanship. In addition, the sealed nickel cadmium batteries carry a (15) year pro-rata warranty.

B row n o u t C i rc u i t ( A P 7 0 )

The brownout circuit on All Pro exits monitors the flow of AC current to the exit and activates the emergency lighting system when a predetermined reduction of AC power occurs. This dip in voltage will cause most ballasted fixtures to extinguish causing loss of normal lighting even though a total power failure has not occurred. Te s t Sw i t ch / Powe r I n d i c a to r L i g h t ( A P 7 0 )

A test switch located on the side of the exit permits the activation of the emergency circuit for a complete operational systems check. The Power Indicator Light provides visual assurance that the AC power is on.

Specifications and dimensions subject to change without notice. Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

ADX041751 pc 2010-08-18 11:37:42 2010-08-18 11:08:54


FIXTURE TYPE F1 MANUFACTURE: METALUX DESCRIPTION: 2X4 STANDARD LENS PART # 2-GR8-332-A-UNV-L8735-EB81 LAMPS: T8 32 L8735 WEB SITE: www.cooperindustries.com FACTORY REP: Specified Lighting 317-577-8100 SUPPLIER: FD Lawrence 317-549-1100 Warranty on Ballast 5 Years from Ship Date 01-02-2011

RETURN SPECIFICATIONS


RETURN

COOPER LIGHTING - METALUX

®

DESCRIPTION

The GR8 is a T8-dedicated lensed troffer designed to offer premium performance in a low profile housing. T8 dedication and optimized lamp to lens spacing provides the best in energy efficiency and optical control. The GR8’s shallow, low profile housing is compatible with even highly restrictive plenums. Luminaires are compatible with today’s popular ceiling systems.

Catalog #

APPLICATION

Prepared by

Type

F1

BMH Sleep Lab

Project

Date

Comments

EMD

The GR8 offers great performance and great quality. The series is an excellent choice for commercial offices, schools, hospitals, retail merchandising and many other applications. SPECIFICATION FEATURES A…Construction

B…Electrical**

E…Frame/Shielding

Unitized low profile recessed housing is die formed of code gauge prime cold rolled steel with full length stiffeners and mechanical endplate attachment for added strength. Off center, ballast cover is easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring for easy lampholder replacement. Ample KOs are provided for continuous row wiring. Built-in grid-lock feature for safety and convenience. Standard unit is NYC Approved. (No modifications necessary).

Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations.

Heavy gauge flat steel door is die formed with reinforced mitered corners. Housing and door frame assemblies incorporate full length and width mechanical light traps. Light stabilized, acrylic prismatic lens.

C…Finish

Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Lighting grade baked white enamel finish with premium reflectance for high efficiency.

2GR8 328T8 332

D…Hinging/Latching

Positive spring loaded cam action steel latches and safety lock Thinges provide secure, high quality door fit and allow hinging and latching from either side.

A

B

C

2' X 4' TROFFER 3 T8 LAMPS

E

General Purpose T8 Commercial Troffer

D

3-3/4" [95mm]

23-3/4" [603mm]

ENERGY DATA MOUNTING DATA

LAMP CONFIGURATIONS

Input Watts: EB Ballast & STD Lamps 328T8 (67) 332 (91)

3-3/4" [95mm] X=5-3/8" [137mm]

1" [26mm] 23-3/4" [603mm]

X

X

23-3/4" [603mm]

Luminaire Efficacy Rating LER = FL-68 Catalog Number: 2GR8-332A

2-11/16" [69mm] 1-1/2" [38mm]

3-7/8" [98mm] 5-3/4" [146mm]

1-1/2" [38mm]

Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.53

47-15/16" [1218mm]

*Standard G (Grid) Type Fixtures can be field converted by adding trim kits. See Compatibility Section or Consult Factory.

DOOR FRAMES 2GR8 Flat, White Steel (White Latches)

**Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. ***Order FCS-24W-U Flange Kit for installation in drywall ceiling. See options and accessories compatibility section.

CEILING COMPATIBILITY G Grid/Lay-in Standard

G Concealed T

COOPER LIGHTING

G Slot Grid

F Flange Trim With Supporting Swing Gates

Ceiling Type

Trim Type

Exposed Grid Concealed T Slot Grid Flange

G G G G***

LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS

Safe and convenient means of disconnecting power.

ADF012708


RETURN

2GR8

PHOTOMETRICS

Coefficients of Utilization

rc rw RCR 0

Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10

1 2 3 4

||

5 6 7 8 9 10

2GR8-332A Electronic Ballast F32T8/35K lamps 2800 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height

Candela

91 84 77 71 66 60 56 51 47 44 41

91 81 72 64 58 51 46 42 37 34 30

91 78 67 59 52 45 40 35 31 27 24

91 75 63 54 47 40 35 31 27 23 20

88 82 75 70 64 59 54 50 46 43 40

88 79 70 63 57 51 46 41 37 33 30

88 76 66 58 51 45 40 35 31 27 24

88 74 63 54 47 40 35 31 27 23 20

20% 50% 50 30 10

30% 50 30 10

10% 50 30 10

0% 0

84 76 68 61 55 49 44 40 36 32 29

81 73 65 59 53 48 43 39 35 31 29

78 70 63 57 51 46 42 38 34 31 28

76 66 57 50 43 37 33 29 25 21 19

84 74 64 57 50 44 39 34 30 27 24

84 72 61 53 46 40 35 31 27 23 20

81 71 62 55 49 43 38 34 30 26 24

81 69 60 52 45 39 35 30 26 23 20

Zonal Lumen Summary

Typical VCP Percentages

Zone 0-30 0-40

Room Size (Ft.) 20 x 20 30 x 30

Efficiency 76.0%

0-60

Test Report: 2GR8332A.IES

0-90 0-180

Lumens

%Lamp

%Fixture

1965 3239 5421 6386 6386

23.4 38.6 64.5 76.0 76.0

30.8 50.7 84.9 100.0 100.0

Height Along 8.5’ 10.0’ 67 71 60 64 52 62 52

30 x 60 60 x 30 60 x 60

55 66 55

78 69 61 54 48 42 38 33 30 26 23

78 67 59 51 45 39 34 30 26 23 20

Height Across 8.5’ 10.0’ 64 68 57 61 47 60 48

Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

Along II 2460 2445 2416 2367 2295 2194 2063 1900 1705 1474 1200 932 710 533 389 275 201 110 0

Across ⊥ 2460 2468 2464 2449 2413 2352 2266 2163 2015 1794 1474 1122 811 566 416 327 251 143 0

45° 2460 2456 2440 2409 2358 2281 2176 2045 1879 1650 1362 1045 745 497 326 243 204 122 0

50 64 51

LER = FL-68 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.53

ORDERING INFORMATION SAMPLE NUMBER: 2GR8-332A-120V-EB81-U 2

GR8

2=2' Width Series GR8=General Purpose T8 Commercial Troffer (1)

3

32

A

UNV

Number of Lamps (2) 3=3 Lamps (Not included)

Wattage (Length) 28T8=28W T8 (48") 32=32W T8 (48") A=#12 Pattern Acrylic A125=#12 Pattern Acrylic (.125" Thick) A19/156=#19 Pattern Acrylic (.156" Thick) IMA 48=Injection Moldeed Acrylic (.150" Thick) PB1S=Silver Parabolic Louver (1/2" x 1/2" x 1/2") (Additional shielding media available, see accessory section)

Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4)

L8735

EB81

U

Ballast Type (3) EB8 = T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. No. of Total Harmonic Distortion < 10% Ballast 1, 2 or 3

Options FCS-24W-U=Field Installed Flange Kit

Packaging U=Unit Pack

(See options & accessories )

ACCESSORIES

EQ-CLIP-U=T-BAR Safety Earthquake Clips(1) ER8 = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 HPT8 Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2

Options GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps Installed Flex=Flex Installed EL=Emergency Installed

SHIPPING INFORMATION (1)

(2)

(3)

NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Standard off-center ballast compartment on 3-lamp fixtures. Products also (4) available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must be specific.

Catalog No.

For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.

2GR8-228T8A 2GR8-332A

Wt. 31 lbs. 31 lbs.

Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801

8/09

ADF012708


FIXTURE TYPE F1T MANUFACTURE: METALUX DESCRIPTION: 2X4 STANDARD LENS PART # 2-GR8-332-A-UNV-L8735-EB81 W-2 BALLAST LAMPS: T8 32 L8735 WEB SITE: www.cooperindustries.com FACTORY REP: Specified Lighting 317-577-8100 SUPPLIER: FD Lawrence 317-549-1100 Warranty on Ballast 5 Years from Ship Date 01-02-2011

RETURN SPECIFICATIONS


COOPER LIGHTING - METALUX

RETURN

®

DESCRIPTION

The GR8 is a T8-dedicated lensed troffer designed to offer premium performance in a low profile housing. T8 dedication and optimized lamp to lens spacing provides the best in energy efficiency and optical control. The GR8’s shallow, low profile housing is compatible with even highly restrictive plenums. Luminaires are compatible with today’s popular ceiling systems.

Catalog #

APPLICATION

Prepared by

Type

F1T

BMH Sleep Lab

Project

Date

Comments

EMD

The GR8 offers great performance and great quality. The series is an excellent choice for commercial offices, schools, hospitals, retail merchandising and many other applications. SPECIFICATION FEATURES A…Construction

B…Electrical**

E…Frame/Shielding

Unitized low profile recessed housing is die formed of code gauge prime cold rolled steel with full length stiffeners and mechanical endplate attachment for added strength. Off center, ballast cover is easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring for easy lampholder replacement. Ample KOs are provided for continuous row wiring. Built-in grid-lock feature for safety and convenience. Standard unit is NYC Approved. (No modifications necessary).

Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations.

Heavy gauge flat steel door is die formed with reinforced mitered corners. Housing and door frame assemblies incorporate full length and width mechanical light traps. Light stabilized, acrylic prismatic lens.

C…Finish

Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Lighting grade baked white enamel finish with premium reflectance for high efficiency.

2GR8 328T8 332

D…Hinging/Latching

Positive spring loaded cam action steel latches and safety lock Thinges provide secure, high quality door fit and allow hinging and latching from either side.

A

B

C

2' X 4' TROFFER 3 T8 LAMPS

E

General Purpose T8 Commercial Troffer

D

3-3/4" [95mm]

23-3/4" [603mm]

ENERGY DATA MOUNTING DATA

LAMP CONFIGURATIONS

Input Watts: EB Ballast & STD Lamps 328T8 (67) 332 (91)

3-3/4" [95mm] X=5-3/8" [137mm]

1" [26mm] 23-3/4" [603mm]

X

X

23-3/4" [603mm]

Luminaire Efficacy Rating LER = FL-68 Catalog Number: 2GR8-332A

2-11/16" [69mm] 1-1/2" [38mm]

3-7/8" [98mm] 5-3/4" [146mm]

1-1/2" [38mm]

Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.53

47-15/16" [1218mm]

*Standard G (Grid) Type Fixtures can be field converted by adding trim kits. See Compatibility Section or Consult Factory.

DOOR FRAMES 2GR8 Flat, White Steel (White Latches)

**Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. ***Order FCS-24W-U Flange Kit for installation in drywall ceiling. See options and accessories compatibility section.

CEILING COMPATIBILITY G Grid/Lay-in Standard

G Concealed T

COOPER LIGHTING

G Slot Grid

F Flange Trim With Supporting Swing Gates

Ceiling Type

Trim Type

Exposed Grid Concealed T Slot Grid Flange

G G G G***

LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS

Safe and convenient means of disconnecting power.

ADF012708


2GR8

RETURN PHOTOMETRICS

Coefficients of Utilization

rc rw RCR 0

Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10

1 2 3 4

||

5 6 7 8 9 10

2GR8-332A Electronic Ballast F32T8/35K lamps 2800 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height

Candela

91 84 77 71 66 60 56 51 47 44 41

91 81 72 64 58 51 46 42 37 34 30

91 78 67 59 52 45 40 35 31 27 24

91 75 63 54 47 40 35 31 27 23 20

88 82 75 70 64 59 54 50 46 43 40

88 79 70 63 57 51 46 41 37 33 30

88 76 66 58 51 45 40 35 31 27 24

88 74 63 54 47 40 35 31 27 23 20

20% 50% 50 30 10

30% 50 30 10

10% 50 30 10

0% 0

84 76 68 61 55 49 44 40 36 32 29

81 73 65 59 53 48 43 39 35 31 29

78 70 63 57 51 46 42 38 34 31 28

76 66 57 50 43 37 33 29 25 21 19

84 74 64 57 50 44 39 34 30 27 24

84 72 61 53 46 40 35 31 27 23 20

81 71 62 55 49 43 38 34 30 26 24

81 69 60 52 45 39 35 30 26 23 20

Zonal Lumen Summary

Typical VCP Percentages

Zone 0-30 0-40

Room Size (Ft.) 20 x 20 30 x 30

Efficiency 76.0%

0-60

Test Report: 2GR8332A.IES

0-90 0-180

Lumens

%Lamp

%Fixture

1965 3239 5421 6386 6386

23.4 38.6 64.5 76.0 76.0

30.8 50.7 84.9 100.0 100.0

Height Along 8.5’ 10.0’ 67 71 60 64 52 62 52

30 x 60 60 x 30 60 x 60

55 66 55

78 69 61 54 48 42 38 33 30 26 23

78 67 59 51 45 39 34 30 26 23 20

Height Across 8.5’ 10.0’ 64 68 57 61 47 60 48

Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

Along II 2460 2445 2416 2367 2295 2194 2063 1900 1705 1474 1200 932 710 533 389 275 201 110 0

Across ⊥ 2460 2468 2464 2449 2413 2352 2266 2163 2015 1794 1474 1122 811 566 416 327 251 143 0

45° 2460 2456 2440 2409 2358 2281 2176 2045 1879 1650 1362 1045 745 497 326 243 204 122 0

50 64 51

LER = FL-68 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.53

ORDERING INFORMATION SAMPLE NUMBER: 2GR8-332A-120V-EB81-U 2

GR8

2=2' Width Series GR8=General Purpose T8 Commercial Troffer (1)

3

32

A

UNV

Number of Lamps (2) 3=3 Lamps (Not included)

Wattage (Length) 28T8=28W T8 (48") 32=32W T8 (48") A=#12 Pattern Acrylic A125=#12 Pattern Acrylic (.125" Thick) A19/156=#19 Pattern Acrylic (.156" Thick) IMA 48=Injection Moldeed Acrylic (.150" Thick) PB1S=Silver Parabolic Louver (1/2" x 1/2" x 1/2") (Additional shielding media available, see accessory section)

Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4)

L8735

EB82

U

Ballast Type (3) EB8 = T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. No. of Total Harmonic Distortion < 10% Ballast 1, 2 or 3

Options FCS-24W-U=Field Installed Flange Kit

Packaging U=Unit Pack

(See options & accessories )

ACCESSORIES

EQ-CLIP-U=T-BAR Safety Earthquake Clips(1) ER8 = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 HPT8 Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2

Options GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps Installed Flex=Flex Installed EL=Emergency Installed

SHIPPING INFORMATION (1)

(2)

(3)

NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Standard off-center ballast compartment on 3-lamp fixtures. Products also (4) available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must be specific.

Catalog No.

For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.

2GR8-228T8A 2GR8-332A

Wt. 31 lbs. 31 lbs.

Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801

8/09

ADF012708


FIXTURE TYPE F2 MANUFACTURE: METALUX DESCRIPTION: 2X4 STANDARD LENS 2 LAMP PART # 2-GR8-232-A-UNV-L8735-EB81 LAMPS: T8 32 L8735 WEB SITE: www.cooperindustries.com FACTORY REP: Specified Lighting 317-577-8100 SUPPLIER: FD Lawrence 317-549-1100 Warranty on Ballast 5 Years from Ship Date 01-02-2011

RETURN SPECIFICATIONS


COOPER LIGHTING - METALUX

RETURN

®

DESCRIPTION

The GR8 is a T8-dedicated lensed troffer designed to offer premium performance in a low profile housing. T8 dedication and optimized lamp to lens spacing provides the best in energy efficiency and optical control. The GR8’s shallow, low profile housing is compatible with even highly restrictive plenums. Luminaires are compatible with today’s popular ceiling systems.

Catalog #

APPLICATION

Prepared by

Type

F2

BMH Sleep Lab

Project

Date

Comments

EMD

The GR8 offers great performance and great quality. The series is an excellent choice for commercial offices, schools, hospitals, retail merchandising and many other applications. SPECIFICATION FEATURES A…Construction

B…Electrical**

E…Frame/Shielding

Unitized low profile recessed housing is die formed of code gauge prime cold rolled steel with full length stiffeners and mechanical endplate attachment for added strength. Off center, ballast cover is easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring for easy lampholder replacement. Ample KOs are provided for continuous row wiring. Built-in grid-lock feature for safety and convenience. Standard unit is NYC Approved. (No modifications necessary).

Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations.

Heavy gauge flat steel door is die formed with reinforced mitered corners. Housing and door frame assemblies incorporate full length and width mechanical light traps. Light stabilized, acrylic prismatic lens.

C…Finish

Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Lighting grade baked white enamel finish with premium reflectance for high efficiency.

2GR8 328T8 332

D…Hinging/Latching

Positive spring loaded cam action steel latches and safety lock Thinges provide secure, high quality door fit and allow hinging and latching from either side.

A

B

C

2' X 4' TROFFER 3 T8 LAMPS

E

General Purpose T8 Commercial Troffer

D

3-3/4" [95mm]

23-3/4" [603mm]

ENERGY DATA MOUNTING DATA

LAMP CONFIGURATIONS

Input Watts: EB Ballast & STD Lamps 328T8 (67) 332 (91)

3-3/4" [95mm] X=5-3/8" [137mm]

1" [26mm] 23-3/4" [603mm]

X

X

23-3/4" [603mm]

Luminaire Efficacy Rating LER = FL-68 Catalog Number: 2GR8-332A

2-11/16" [69mm] 1-1/2" [38mm]

3-7/8" [98mm] 5-3/4" [146mm]

1-1/2" [38mm]

Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.53

47-15/16" [1218mm]

*Standard G (Grid) Type Fixtures can be field converted by adding trim kits. See Compatibility Section or Consult Factory.

DOOR FRAMES 2GR8 Flat, White Steel (White Latches)

**Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. ***Order FCS-24W-U Flange Kit for installation in drywall ceiling. See options and accessories compatibility section.

CEILING COMPATIBILITY G Grid/Lay-in Standard

G Concealed T

COOPER LIGHTING

G Slot Grid

F Flange Trim With Supporting Swing Gates

Ceiling Type

Trim Type

Exposed Grid Concealed T Slot Grid Flange

G G G G***

LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS

Safe and convenient means of disconnecting power.

ADF012708


2GR8

RETURN PHOTOMETRICS

Coefficients of Utilization

rc rw RCR 0

Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10

1 2 3 4

||

5 6 7 8 9 10

2GR8-332A Electronic Ballast F32T8/35K lamps 2800 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height

Candela

91 84 77 71 66 60 56 51 47 44 41

91 81 72 64 58 51 46 42 37 34 30

91 78 67 59 52 45 40 35 31 27 24

91 75 63 54 47 40 35 31 27 23 20

88 82 75 70 64 59 54 50 46 43 40

88 79 70 63 57 51 46 41 37 33 30

88 76 66 58 51 45 40 35 31 27 24

88 74 63 54 47 40 35 31 27 23 20

20% 50% 50 30 10

30% 50 30 10

10% 50 30 10

0% 0

84 76 68 61 55 49 44 40 36 32 29

81 73 65 59 53 48 43 39 35 31 29

78 70 63 57 51 46 42 38 34 31 28

76 66 57 50 43 37 33 29 25 21 19

84 74 64 57 50 44 39 34 30 27 24

84 72 61 53 46 40 35 31 27 23 20

81 71 62 55 49 43 38 34 30 26 24

81 69 60 52 45 39 35 30 26 23 20

Zonal Lumen Summary

Typical VCP Percentages

Zone 0-30 0-40

Room Size (Ft.) 20 x 20 30 x 30

Efficiency 76.0%

0-60

Test Report: 2GR8332A.IES

0-90 0-180

Lumens

%Lamp

%Fixture

1965 3239 5421 6386 6386

23.4 38.6 64.5 76.0 76.0

30.8 50.7 84.9 100.0 100.0

Height Along 8.5’ 10.0’ 67 71 60 64 52 62 52

30 x 60 60 x 30 60 x 60

55 66 55

78 69 61 54 48 42 38 33 30 26 23

78 67 59 51 45 39 34 30 26 23 20

Height Across 8.5’ 10.0’ 64 68 57 61 47 60 48

Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

Along II 2460 2445 2416 2367 2295 2194 2063 1900 1705 1474 1200 932 710 533 389 275 201 110 0

Across ⊥ 2460 2468 2464 2449 2413 2352 2266 2163 2015 1794 1474 1122 811 566 416 327 251 143 0

45° 2460 2456 2440 2409 2358 2281 2176 2045 1879 1650 1362 1045 745 497 326 243 204 122 0

50 64 51

LER = FL-68 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.53

ORDERING INFORMATION SAMPLE NUMBER: 2GR8-332A-120V-EB81-U 2

GR8

2=2' Width Series GR8=General Purpose T8 Commercial Troffer (1)

2

32

A

UNV

Number of Lamps (2) 3=3 Lamps (Not included)

Wattage (Length) 28T8=28W T8 (48") 32=32W T8 (48") A=#12 Pattern Acrylic A125=#12 Pattern Acrylic (.125" Thick) A19/156=#19 Pattern Acrylic (.156" Thick) IMA 48=Injection Moldeed Acrylic (.150" Thick) PB1S=Silver Parabolic Louver (1/2" x 1/2" x 1/2") (Additional shielding media available, see accessory section)

Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4)

L8735

EB81

U

Ballast Type (3) EB8 = T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. No. of Total Harmonic Distortion < 10% Ballast 1, 2 or 3

Options FCS-24W-U=Field Installed Flange Kit

Packaging U=Unit Pack

(See options & accessories )

ACCESSORIES

EQ-CLIP-U=T-BAR Safety Earthquake Clips(1) ER8 = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 HPT8 Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2

Options GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps Installed Flex=Flex Installed EL=Emergency Installed

SHIPPING INFORMATION (1)

(2)

(3)

NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Standard off-center ballast compartment on 3-lamp fixtures. Products also (4) available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must be specific.

Catalog No.

For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.

2GR8-228T8A 2GR8-332A

Wt. 31 lbs. 31 lbs.

Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801

8/09

ADF012708


FIXTURE TYPE F3 MANUFACTURE: METALUX DESCRIPTION: WALL MOUNT FIXTURE PART # BUI 2 32 UNV EB81 LAMPS: T8 32 L8735 WEB SITE: www.cooperindustries.com FACTORY REP: Specified Lighting 317-577-8100 SUPPLIER: FD Lawrence 317-549-1100 Warranty on Ballast 5 Years from Ship Date 01-02-2011

RETURN SPECIFICATIONS


RETURN

""* ,Ê / Ê Ê / 18

DESCRIPTION

The BI Series fills the need for a very low brightness wall bracket. This specification grade wall bracket with an injection molded refractor produces effective up, down or combination lighting. This energy efficient luminaire offers up lighting, multi-level switching and convenience outlets as options. These design features ensure that the BI Series will offer ease of use and comfort. The BI Series features specification efficiency in a low profile wall bracket. The Series is an excellent choice for dressing rooms, lavatories, hospital and nursing homes, stairways and task lighting.

Type

Catalog # Project

F3

BMH Sleep Lab

Date

Comments Prepared by

Á

EMD

SPECIFICATION FEATURES

C ... Finish Painted after fabrication. Electrostatically applied baked white polyester powder enamel finish. Multistage cleaning cycle, iron phosphate coating with rust inhibitor. Conveyorized application and baking timing accurately controlled at an elevated temperature.

A ... Construction Housing die formed code gauge cold rolled steel. Channel cover secured by quarter-turn fasteners for easy wiring. Up, down or combination lighting with 3 and 4 foot fixtures. Decorative opaque injection molded end plates. B ... Electrical Ballast are CBM/ETL Class "P" and positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations.

A

B

C

D ... Frame/Shielding Injection molded 100% virgin acrylic diffuser and end cap. Quadrasided diffuser prism shapes accurately molded for optimum light brightness control. Diffuser slides forward for easy installation and maintenance. Uplight diffuser prismatic acrylic.

BI, BIU 120 117 130 125 140 132 220 217 230 225 240 232

D

3-1/2" [89mm]

7-1/2" [190mm]

MOUNTING DATA

1" [25mm] 3-1/2" [89mm]

Ceiling Stand-Off Ground Screw Bump Embossments 7/8" K.O. (1) 1-3/4" Keyhole [44mm]

7/8" K.O. (1) Ground Screw Bump Stand-Off Embossments

1" [25mm] 3-1/2" [89mm]

5-7/8" [149mm] 16" [406mm] 24-3/4" [629mm]

COMMERCIAL PLUS WALL BRACKET 2' Wall Bracket 1 or 2 Lamp LTS or HTS 3' or 4' Wall Bracket 1 or 2 Lamp

1-3/4" [44mm]

Keyhole

32" [813mm] 36-3/4" [933mm]

LAMP CONFIGURATIONS

X

X

X=3-1/2" [89mm]

X=3-1/2" [89mm]

7-1/2" [190mm]

X

X

X=3-1/2" [89mm]

X=3-1/2" [89mm]

7-1/2" [190mm]

1" [25mm] 7-1/2" [190mm]

7-1/2" [190mm]

7/8" [22mm] K.O. (3) Ceiling Stand-Off Embossments

Ground Screw Bump Keyhole

3-1/2" [89mm]

1-3/4" [44mm]

32" [813mm] 40-5/8" [1032mm] 48-3/4" [1238mm]

LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS

Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes.

Safe and convenient means of disconnecting power

ADF020687 10/31/2007 2:26:22 PM


RETURN

BI, BIU

PHOTOMETRICS

iÀ}ÞÊ->Û }Ê > >ÃÌ]Ê ÎÓ/nÉÎx Ê > «ÃÊÀ>Ìi`Ê>ÌÊÓnxäÊ Õ i ð -«>V }ÊVÀ ÌiÀ \Ê­ ®£°ÈÊÝÊ Õ Ì }Ê i } Ì]Ê­ ®£°ÎÊÝÊ Õ Ì } i } Ì°

} ÌÊ ÃÃÊ >VÌ ÀÊ°Ç{°Ê ÀÊV « iÌiÊ« Ì iÌÀ VÊÀi« ÀÌÊÀiµÕiÃÌ Ài« ÀÌÊ ÓÎÓ° -

ÓÎÓ > «Ã

­Ó®Ê ÎÓ/nÉÎx

Õ i à ÓnxäÊ >V

` Ì Ã

ο ä¸

, Ê- âiÊ

£Ó¿Ê7 `Ì ÊÝ £{¿Ê i }Ì È¿ ä¸

i }Ê i } Ì ¿ ä¸

Èn°x

xΰÓ

,iv iVÌ> Vi

nΰ

Ó°ä

n{°ä

x롊

È{°ä

È °

È{°£

£¿

Èn°Î

nä¯

7> Ã

xä¯

À

Óä¯

룡

룡n

ÎÇ°x

{ä°Ç

i }

ӿ ο

ÎÇ°x

£n°x

Óä°n

ÓÓ°£

£Ó°Î

Óä°n

£n°È

{¿ x¿

£Î°£ £Î°È

£Î°£

£Ó°Î

È¿

°Ó °{

Ç°ä

°Ó

Ç¿

Ç°£

Ç°Ó Ç°Ó

ÊÊ

Ç°ä

ο ä¸ £Ó¸ ¸

-V> iÊ ÃÊ Ý>}}iÀ>Ìi`Ê Ê ÝÌÕÀi «« V>Ì Ê> `Ê Õ Ì } ORDERING INFORMATION Sample Number: BI-232-120V-EB81-U

BIU

2

Series BI=Steel Wall Bracket Downlight only Steel Wall Bracket (Up =Steel BIU= and Down Light) Number of Lamps 1 Lamp (Not Included) 2 Lamps (Not Included) Wattage 20=20W T12 (24") 17=17W T8 (24") 25=25W T8 (36") 30=30W T12 (36") 32 2=32W T8 (48") 40=40W T12 (48")

UNV

32 Ballast Start Type LTS=Low Trigger Start (20W only) (120V only) HTS=High Trigger Start (20W only)

Ballast Type

1

8 1

Blank=Standard Magnetic T12 Ballast EB B=Electronic Instant Start ER=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%

Voltage e2

Options GL=Single Element Fuse

RS1=Rotary Switch (1 Circuit, 120V only)

GM=Double Element Fuse EL=Emergency Installed

Products also available in non-US voltage and freqeuncies for international markets Not Available when specifying emergencies, voltage must be specific

RLS=Rotor Lock Socket (T8 Lamp only)

BH=Matte Black Finish (Lens Housing) CO=Convenience Outlet (120V only)

2=2 Ballast

PS1=Pull Switch (1 Circuit) RS1D=Rotary Switch wired to Downlight Circuit on a two circuit fixture (120V only)

Catalog No.

2

Packaging U=Unit Pack

PL5PL7=Fluorescent Night Light (5 or 7 Watt) only available in fixtures without a baffle

Number of Ballasts 1=1 Ballast

SHIPPING INFORMATION

Notes: 1

Options PLUS=Higher Ballast Factor > 1.13. Total Harmonic Distortion < 20%

INL=Incandescent Night Light (up to 40 Watt)

8=T8

277V=277 Volt 347V=347 Volt

U

2/1LB=(2) One-Lamp Ballasts (When RS4 or PS4 option is used)

Lamp Size 2=T12

Voltage 1 120V=120 Volt

UNV V=Universal 120-277

EB

BI-117 BI-125 BI-132 BIU-117 BIU-125 BIU-132 BI-217 BI-225 BI-232 BIU-217 BIU-225 BIU-232

Wt. 8 lbs. 11 lbs. 14 lbs. 8 lbs. 11 lbs. 14 lbs. 8 lbs. 11 lbs. 14 lbs. 8 lbs. 11 lbs. 14 lbs.

PS1D=Pull Switch, wired to Downlight Circuit on a two circuit fixture (120V only) RS4=Four-way rotary switch, for two 1 circuit, two lamp fixture (120V only) PS4=Four-way pull switch, for two circuit 2 lamp fixture (120V only)

Specifications and Dimensions subject to change without notice. Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

ADF020687 10/31/2007 2:26:22 PM


FIXTURE TYPE F4 MANUFACTURE: METALUX DESCRIPTION: 2X2 DIRECT INDIRECT PART # 2RDI-217RP-UNV-L8735-EB8 LAMPS: 17WT8 L8735 WEB SITE: www.cooperindustries.com FACTORY REP: Specified Lighting 317-577-8100 SUPPLIER: FD Lawrence 317-549-1100 Warranty on Ballast 5 Years from Ship Date 01-02-2011

RETURN SPECIFICATIONS


RETURN

COOPER LIGHTING - METALUX

®

DESCRIPTION

The Ovation Series is a complete family of recessed direct/indirect luminaires featuring pleasant modern architectural styling, computerdesigned optics and the latest energy efficient lamp and ballast technology. The luminaire combines a matte white indirect reflector and a perforated direct lamp shield to provide optimum brightness control. All components are located above the ceiling plane for a clean architectural appearance in the finished space. Carefully balanced design elements combine to provide an efficient and exciting alternative to traditional general lighting. Ovation is an excellent choice for a wide variety of commercial applications.

Type

Catalog #

F4

BMH Sleep Lab

Project

Date

Comments Prepared by

EMD

SPECIFICATION FEATURES A…Construction

C…Ballast Access

E…Ref lector s

Nominal 6" deep housing is die formed of code gauge, prime cold rolled steel. Heavy gauge end plates are securely attached with screws for strength and rigidity and the elimination of gaps. Four auxiliary fixture end suspension points are provided. KOs for continuous row wiring. Large access plate for supply connection.

Ballast can be removed from below without tools or from above using the unique ballast mounting/access plate.3

Indirect reflector has high reflectance baked matte white enamel finish for luminous uniformity. A positively retained direct lamp shield is constructed of heavy gauge perforated steel with high reflectance painted after fabrication finish and milky white overlay diffuser for visual comfort. All reflectors are precision formed in a computer-controlled operation

B…Electrical*

Ballasts are CBM/ETL Class “P” and are positively secured. Biax models use 2G11 base lampholders with double edge wiping action pressure lock contacts and vertically oriented lamp support clips. T8 models use rotor-lock lampholders for positive lamp retention. UL/CUL listed. Suitable for damp locations.

D…Finish

Durable cold rolled steel with multistage, iron phosphate pretreatment and white enamel finish to ensure maximum bonding and rust inhibition.

A

B C

E

E

2RDI 1BX40 2BX40 3BX40 117 217 317

D

BIAXIAL OR T8 LAMPS

2' X 2' Recessed Direct/Indirect C e n t e r- M o u n t

6" [152mm]

ENERGY DATA Input Watts:

23-3/4" [603 mm]

LAMP CONFIGURATIONS

MOUNTING DATA

6" [152mm]

Ballast Access Plate 8" [203mm] 23-3/4" [603mm]

23-11/16" [602mm] Wiring Access Plate 7/8" [22mm] K.O. (2)

EB Ballast & STD Lamps 1BX40 (43), 2BX40 (67), 3BX40 (102) 1BX50 (54), 2BX50 (106), 3BX50 (160) 1BX55 (59), 2BX55 (117), 3BX55 (176) 117 (19), 217 (34), 317 (54) 6" [152mm]

8" [203mm] 23-3/4" [603mm] 6" [152mm]

1-1/2" [38mm]

2-1/2" [64mm]

9-11/16" [246mm]

3-1/4" [83mm]

2-3/4" [70mm]

8" [203mm] 23-3/4" [603mm]

23-3/4" [603mm]

6" [152mm]

23-3/4" [603mm]

7/8" [22mm] K.O. (1) 6" [152mm]

23-3/4" [603mm]

COOPER LIGHTING

1-5/8" [41mm]

8" [203mm] 23-3/4" [603mm]

1-5/8" [41mm]

6" [152mm]

8" [203mm] 23-3/4" [603mm]

STD Ballast & STD Lamps 1BX40 (46), 2BX40 (82), 3BX40 (128) Luminaire Efficacy Rating LER = FL65 Catalog Number: 2RDI-2BX40RP Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.69 *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. **Consult Pre Sales Technical Support. ***See Drywall Frame Kit Accessory

CEILING COMPATIBILITY

BIAX MODEL

T8 MODEL

8" [203mm] 23-3/4" [603mm]

6" [152mm]

7/8" [22mm] K.O. (1)

6-9/16" [167mm]

3-1/4" [83mm]

6" [152mm]

ES Ballast & STD Lamps 117 (23), 217 (45), 317 (68)

G Grid/Lay-in Standard

T Slot Grid

F Drywall Frame Kit

Ceiling Type**

Trim Type

Exposed Grid Concealed T Slot Grid Flange

G G or T G or T ***

LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS

Safe and convenient means of disconnecting power.

ADF020601


2RDI

RETURN PHOTOMETRICS

Coefficients of Utilization

Candela

Effective floor cavity reflectance

rc rw RCR 0 1 2

||

2RDI-2BX40RP Electronic Ballast F40BX/35K/RS Lamps 3150 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height

3 4 5 6 7 8 9 10

80% 70 50 30 10 93 86 79 72 66 60 55 51 47 43 40

93 82 73 64 57 50 45 40 36 32 29

93 79 68 58 51 44 38 34 30 26 23

93 76 63 53 46 38 33 29 25 21 19

20%

70% 70 50 30 10

50% 50 30 10

30% 50 30 10

10% 50 30 10

0% 0

91 84 77 70 64 59 54 50 46 42 39

87 77 68 61 54 48 43 39 35 31 28

83 74 66 59 52 46 42 37 34 30 28

80 71 63 57 51 45 40 36 33 29 27

78 67 57 49 42 35 31 27 23 20 17

91 81 71 63 56 50 44 40 36 32 29

91 78 66 57 50 43 38 33 29 26 23

91 75 63 53 45 38 33 29 25 21 19

87 75 64 56 49 42 37 33 29 25 23

87 73 61 52 45 38 33 29 25 21 19

83 72 63 55 48 41 36 32 28 25 22

83 71 60 51 44 37 33 28 25 21 19

Zonal Lumen Summary

Typical VCP Percentages

Zone 0-30 0-40

Room Size (Ft.) 20 x 20 30 x 30

Efficiency 78.2%

0-60

Test Report: 2RDI2BX40RP.IES

0-90 0-180

Lumens

%Lamp

%Fixture

1339 2205 3932 4926 4926

21.2 35.0 62.4 78.2 78.2

27.2 44.8 79.8 100.0 100.0

Height Along 8.5’ 10.0’ 48 54 44 46 43 43 47 48 44 44

30 x 60 60 x 30 60 x 60

80 70 61 53 47 41 36 32 28 25 22

80 69 58 50 43 37 32 28 24 21 19

Height Across 8.5’ 10.0’ 41 48 38 40 35 35 43 45 38 38

Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

Along II 1701 1701 1677 1634 1574 1497 1406 1301 1182 1052 912 762 610 465 334 217 119 48 0

45° 1701 1698 1682 1648 1599 1539 1468 1386 1292 1186 1067 933 792 637 466 305 176 66 0

Across ⊥ 1701 1700 1689 1665 1631 1587 1533 1465 1381 1282 1167 1029 867 683 520 362 205 72 0

LER = FL65 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.69 ORDERING INFORMATION SAMPLE NUMBER: 2RDI-2BX40RP-120V-EB51-U

Rating Blank= Standard NY=New York City Rated ATW-SW4= Chicago Rated Width 2=2' Width Series RDI=Ovation Series (Recessed Direct/Indirect)

Number of Lamps 1=1 Lamp 2= 2 Lamp 3= 3 Lamp

Voltage (2) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277

Wattage 17=17W T8 (24") BX40=40W Biax (24") BX50=50W Biax (24")(1) BX55=55W Biax (24")(1) Lamp Shield X=Solid Matte White RP=Round Perforated White Steel

Options Lamps=Lamps Installed GL=Single Element Fuse GM=Double Element Fuse Flex=Flex Installed EL=Emergency Installed

Trim Type Blank=Grid/Lay-in (Standard) Lamp Position Blank=Center Mounted Lamps (standard)

(1)

(2)

NOTES: 2' x 2' and 2' x 4' Center Lamp Shield models only. Products also available in non-US volt(3) ages and frequencies for international markets. Not available in UNV voltages. Must specify voltage. (4) An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.

Ballast Type (2) EB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. No. of Total Harmonic Distortion < 10% Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 HPT8 Ballast ( __ = no. of Ballast, 1 or 2) HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 EB5

Packaging Options RIF1=Radio Interference U=Unit Pack Suppressor PALC=Job REP=Riveted Endplates, for Pack, in carton use in New York City. ST=Semi-Specular Tannenbaum Main Reflector LSC=Lamp Shield Cable RLS=Rotor-Lock Socket (T8 Lamps Only)

ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(4) DF-22-W=Drywall Frame Kit

(3)

=T5 Biax Electronic Instant Start. Total Harmonic Distortion < 20% No. of Ballast 1 or 2 TEB5 (3)= T5 Biax Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 ER5 (3)=T5 Biax Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2

SHIPPING INFORMATION Catalog No.

Wt.

2RDI-1BX40RP 2RDI-2BX40RP 2RDI-3BX40RP 2RDI-117RP 2RDI-217RP 2RDI-317RP

19 lbs. 19 lbs. 19 lbs. 19.5 lbs. 19.5 lbs. 19.5 lbs.

Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801

3/10

ADF020601


FIXTURE TYPE F5 MANUFACTURE: METALUX DESCRIPTION: 2X4 DIRECT INDIRECT OVATION DIMABLE FLUORESENT W-LUTRON HI LUME BALLAST PART # 2RDI-232RP-120V-L8735-LU-H3DT832CU210-U LAMPS: T8 L8735 WEB SITE: www.cooperindustries.com FACTORY REP: Specified Lighting 317-577-8100 SUPPLIER: FD Lawrence 317-549-1100 Warranty on Ballast 2 Years from Ship Date 01-02-2011

RETURN SPECIFICATIONS


RETURN

COOPER LIGHTING - METALUX

®

DESCRIPTION

The Ovation Series is a complete family of recessed direct/indirect luminaires featuring pleasant modern architectural styling, computerdesigned optics and the latest energy efficient lamp and ballast technology. The luminaire combines a matte white indirect reflector and a perforated direct lamp shield to provide optimum brightness control. All components are located above the ceiling plane for a clean architectural appearance in the finished space. Carefully balanced design elements combine to provide an efficient and exciting alternative to traditional general lighting. Ovation is an excellent choice for a wide variety of commercial applications.

Type

Catalog # Project

F5

BMH Sleep Lab

Date

Comments Prepared by

EMD

SPECIFICATION FEATURES A…Construction

C…Ballast Access

E…Ref lector s

Nominal 6" deep housing is die formed of code gauge, prime cold rolled steel. Heavy gauge end plates are securely attached with screws for strength and rigidity and the elimination of gaps. Four auxiliary fixture end suspension points are provided. KOs for continuous row wiring. Large access plate for supply connection.

Ballast can be removed from below without tools or from above using the unique ballast mounting/access plate.3

Indirect reflector has high reflectance baked matte white enamel finish for luminous uniformity. Positively retained direct lamp shield is constructed of heavy gauge perforated steel with high reflectance painted after fabrication finish and milky white overlay diffuser for visual comfort. All reflectors are precision formed in a computer-controlled operation.

D…Finish

Durable cold rolled steel with multistage, iron phosphate pretreatment and white enamel finish to ensure maximum bonding and rust inhibition.

B…Electrical*

Ballasts are CBM/ETL Class “P” and are positively secured. Biax models use 2G11 base lampholders with double edge wiping action pressure lock contacts and vertically oriented lamp support clips. T8 models use rotor-lock lampholders for positive lamp retention. UL/CUL listed. Suitable for damp locations.

B

A

C

E

E

D

2RDI 128T8 132 228T8 232 328T8 332 T1BX40,T2BX40 T3BX40 T8 OR BIAXIAL LAMPS

2' X 4' Recessed Direct/Indirect C e n t e r- M o u n t

6" [152mm]

ENERGY DATA

23-3/4" [603 mm]

Input Watts:

MOUNTING DATA

LAMP CONFIGURATIONS 7/8" [22mm] K O (1) 6" [152mm]

6" [152mm] 1 5/8" [41mm]

6 9/16" [167mm]

T8 MODEL

23 3/4" [603mm]

8" [203mm] 23 3/4" [603mm]

7/8" [22mm] K O (1)

6" [152mm] 6" [152mm] 1 5/8" [41mm]

Ballast Access Plate

47-11/16" [1211mm]

BIAX MODEL

23 3/4" [603mm]

8" [203mm] 23 3/4" [603mm]

G Grid/Lay-in Standard 1-1/2" [38mm]

2-1/2" [64mm]

2-3/4" [70mm] 23-3/4" [603mm]

COOPER LIGHTING

9-11/16" [246mm]

T Slot Grid

F Drywall Frame Kit

Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.69 *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. **Consult Pre Sales Technical Support. ***See Drywall Frame Kit Accessory

CEILING COMPATIBILITY

Wiring Access Plate 7/8" [22mm] K.O. (2)

EB Ballast & STD Lamps 128T8 (28), 228T8 (49), 328T8 (98) 132 (32), 232 (61), 332 (91), T1BX40 (70), T2BX40 (140), T3BX40 (210) T1BX50 (106), T2BX50 (212) T3BX50 (318) T1BX55 (110), T2BX55 (220) T3BX55 (330) LER = FL65 Catalog Number: 2RDI-232RF

Ceiling Type**

Trim Type

Exposed Grid Concealed T Slot Grid Flange

G G or T G or T ***

LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS

Safe and convenient means of disconnecting power.

ADF091048


2RDI

RETURN PHOTOMETRICS

Coefficients of Utilization

rc rw RCR 0 1 2 3 4 5 6

2RDI-232RP Electronic Ballast F032/830/XP3 Lamps 3100 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height

7 8 9 10

Candela

Effective floor cavity reflectance 80% 70% 70 50 30 10 84 77 69 63 57 53 48 45 42 39 36

84 73 63 55 49 43 39 35 32 29 27

84 70 58 49 42 37 32 29 26 23 21

84 67 54 44 37 32 28 24 21 19 17

20% 50%

30%

10%

70 50 30 10

50 30 10

50 30 10

50 30 10

0

82 75 67 61 56 51 47 44 41 38 36

79 68 59 52 46 41 37 33 30 28 26

75 66 57 50 44 39 36 32 30 27 25

72 63 55 48 43 38 34 31 29 26 24

71 58 48 40 34 29 25 22 20 18 16

82 71 62 54 48 42 38 34 31 29 27

82 68 57 48 42 36 32 28 25 23 21

82 66 53 44 37 32 27 24 21 19 17

79 66 55 47 41 35 31 28 25 23 21

79 64 52 43 36 31 27 24 21 19 17

75 64 54 46 40 35 31 27 25 22 20

Zonal Lumen Summary

Luminance Data

Zone 0-30 0-40

Angle in Deg 0-30 0-40

Efficiency 70.7 %

0-60

Test Report: 2RDI232RP.IES

0-90 0-180

Lumens

%Lamp

%Fixture

17.6 29.2 53.9 70.7 70.7

24.8 41.3 76.2 100.0 100.0

1088.56 1810.67 3339.06 4383.85 4383.85

0%

0-60 0-90 0-180

75 62 51 42 36 31 27 24 21 19 17

72 61 52 45 39 34 30 27 24 22 20

72 60 50 42 35 31 27 24 21 19 17

Average 0-Deg cd/sm 1801 1693

Average 45-Deg cd/sm 2068 2130

Average 90-Deg cd/sm 2279 2393

1519 1284 953

2142 1893 1397

2380 2125 1545

Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

Along II 1372 1367 1348 1316

45° 1372 1370 1357 1334

Across 1372 1374 1365 1351

1273 1216 1148 1071 984 889 785 678 564 448 335 232 139 58 0

1302 1261 1212 1156 1092 1021 941 853 753 632 498 342 205 85 0

1332 1304 1271 1231 1182 1125 1053 958 846 702 539 384 228 94 0

LER = FL61 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.93

Lutron Hi-Lume Dimming H3DT832CU210

ORDERING INFORMATION SAMPLE NUMBER: 2RDI-232RP-120V-EB51-U

Rating Blank= Standard NY=New York City Rated ATW-SW4= Chicago Rated Width 2=2' Width Series RDI=Ovation Series (Recessed Direct/Indirect) Trim Type Leave Blank=Grid/Lay-in (Standard)

Number of Lamps 1=1 Lamp 2=2 Lamp 3=3 Lamp T1=2' x 4' Fixture with One Biax Lamp at Each End T2=2' x 4' Fixture with Two Biax Lamps at Each End T3=2' x 4' Fixture with Three Biax Lamps at Each End

Lamp Shield X=Solid Matte White RP=Round Perforated White Steel Voltage (2) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 Options GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps Installed Flex=Flex Installed EL=Emergency Installed

Lamp Position Leave Blank=Center Mounted Lamps (Standard) Wattage 28T8=28W T8 (48") 32=32W T8 (48") BX40=40W Biax (24") BX50=50W Biax (24")(1) BX55=55W Biax (24")(1)

(1)

(2)

NOTES: 2' x 2' and 2' x 4' Center Lamp Shield models only. Products also available in non-US (3) voltages and frequencies for international markets. Not available in UNV voltages. Must specify (4) voltage. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.

2) Ballast Type ((2) EB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. No. of Total Harmonic Distortion < 10% Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 HPT8 Ballast ( __ = no. of Ballast, 1 or 2) HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2

EB5

(3)

=T5 Biax Electronic Instant Start. Total Harmonic Distortion < 20% No. of Ballast 1 or 2 TEB5 (3)= T5 Biax Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 ER5 (3)=T5 Biax Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2

Packaging Options RLS=Rotor-Lock Socket U=Unit Pack (T8 Lamps Only) PALC=Palletize RIF1=Radio Interference d Fixtures in Suppressor Carton REP=Riveted Endplates LSC=Lamp Shield Cable ST=Semi-Specular Tannenbaum

ACCESSORIES EQ=T-BAR Safety Earthquake Clips(4) DF-24-W=Drywall Frame Kit

SHIPPING INFORMATION Catalog No.

Wt.

2RDI-132RP 2RDI-128T8RP 2RDI-232RP 2RDI-228T8RP 2RDI-332RP 2RDI-328T8RP 2RDI-T1BX40 2RDI-T2BX40 2RDI-T3BX40

30 lbs. 30 lbs. 30 lbs. 30 lbs. 30 lbs. 30 lbs. 31 lbs. 31 lbs. 31 lbs.

Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801

3/10

ADF091048


FIXTURE TYPE F6 MANUFACTURE: METALUX DESCRIPTION: 1X4 RECESSED 2 LAMP PART # GR8 232 A UNV L EB8 1 LAMPS: T8 L8735 WEB SITE: www.cooperindustries.com FACTORY REP: Specified Lighting 317-577-8100 SUPPLIER: FD Lawrence 317-549-1100 Warranty on Ballast 5 Years from Ship Date 01-02-2011

RETURN SPECIFICATION


RETURN

""* ,Ê / Ê Ê / 18

DESCRIPTION

The GR8 is a T8-dedicated lensed troffer designed to offer premium performance in a low profile housing. T8 dedication and optimized lamp to lens spacing provides the best in energy efficiency and optical control. The GR8's shallow, low profile housing is compatible with even highly restrictive plenums. Luminaires are compatible with today's popular ceiling systems.

Type

Catalog #

F6

BMH Sleep Lab

Project

Date

Comments

The GR8 offers great performance and great quality. The series is an excellent choice for commercial offices, schools, hospitals, retail merchandising and many other applications.

Á

Prepared by

EMD

SPECIFICATION FEATURES

A ... Construction Low profile recessed housing is die formed of code gauge prime cold rolled steel with full length stiffeners and mechanical endplate attachment for added strength. Ballast cover is easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring for easy lampholder replacement. Ample KOs are provided for continuous row wiring. Built-in grid-lock feature for safety and convenience.

B ... Electrical** Ballasts are CBM/ETL Class "P" and are positively secured. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. C ... Finish Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Lighting grade baked white enamel finish with premium reflectance for high efficiency.

E ... Frame/Shielding Heavy gauge flat steel door is die formed with reinforced mitered corners. Housing and door frame assemblies incorporate full length and width mechanical light traps. Light stabilized, acrylic prismatic lens.

GR8 232

D ... Hinging/Latching Positive cam action steel latches and integral safety hinges provide secure, high quality door fit and allow hinging and latching from either side.

1' X 4' TROFFER 2 LAMP General Purpose T8 Commercial Troffer

Î ÎÉ{¸ Q x R

££ ÎÉ{¸ÊQÓ n R

MOUNTING DATA

DOOR FRAMES VViÃÃÊ* >Ìi ÇÉn¸ÊQÓÓ RÊ °"°Ê­Ó® £ £ÉÓ¸Ê QÎn R

ÇÉn¸ÊQÓÓ RÊ °"°Ê­Ó®

,n >Ì]Ê7 ÌiÊ -Ìii Ê­7 ÌiÊ >ÌV iî

££ ÎÉ{¸ QÓ n R

x ÎÉ{¸ÊQ£{È R Î £ÉÓ¸ÊQn R

n ÇÉÎÓ¸ÊQÓä R {n¸ÊQ£Ó£ R

LAMP CONFIGURATIONS Î ÎÉ{¸ÊQ x R x¸ Q£ÓÇ R ££ ÎÉ{¸ QÓ n R

CEILING COMPATIBILITY À `É >Þ -Ì> `>À`

Vi> i`Ê/

- ÌÊ À `

> }iÊ/À 7 Ì Ê-Õ«« ÀÌ } -Ü }Ê >ÌiÃ

i } /Þ«i

/À /Þ«i

Ý« Ãi`Ê À `

Vi> i`Ê/ - ÌÊ À ` > }i

III

­6iÀ vÞÊV «>Ì L ÌÞÉÊV ÃÕ Ì v>VÌ ÀÞ°®

Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes.

LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS

Safe and convenient means of disconnecting power

ADF031753 11/07/2007 2:05:51 PM


RETURN

PHOTOMETRICS

GR8

ivv V i ÌÃÊ vÊ1Ì â>Ì

> ` i« ÜiÀ

vviVÌ ÛiÊv ÀÊV>Û ÌÞÊÀiv iVÌ> Vi ÀV ÀÜ

\\

, , ä £ >

Ó Î { x È

,n ÓÎÓ iVÌÀ VÊ > >ÃÌ ÎÓ/nÉÎx Ê > «Ã ÓnääÊ Õ i à -«>V }ÊVÀ ÌiÀ \ ­ ®Ê£°ÓÊÝÊ Õ Ì } i } Ì]Ê­>®Ê£°ÓÊÝ Õ Ì }Ê i } Ì vv V i VÞÊÈn°Ó¯

Ç n £ä

nä¯ Çä xä Îä £ä n£ Çx Çä Èx Èä xx x£ {Ç {{

n£ Çä È£ x{ {Ç {Ó ÎÇ ÎÎ Îä

n£ Èn xn xä {Î În ÎÎ Ó ÓÈ

{ä ÎÓ ÓÈ ÓÎ În Ó Ó{ Óä

} i

xä¯ xä Îä £ä

Îä¯ xä Îä £ä

£ä¯ xä Îä £ä

ä¯ ä

Ç Ç{ Èn ÈÎ xn x{ xä {È {Î

ÇÎ ÈÈ x x{ { {{ {ä ÎÈ ÎÎ

Ç Ç£ È{ xn xÓ {Ç {Ó În Îx

Ç È Èä xÎ {Ç {£ ÎÇ ÎÎ Ó

Ç ÈÇ xÇ xä {Î În ÎÎ Ó ÓÈ

ÇÈ Èn È£ xÈ xä {x {£ ÎÇ Î{

ÇÈ ÈÈ xn xÓ {È {£ ÎÈ ÎÎ Ó

ΠΣ ÎÇ Ón

ÓÈ ÓÎ

ÓÓ Óä

Îä Ón

ÓÈ ÓÓ ÓÎ Óä

< > Ê Õ i Ê-Õ >ÀÞ < i

Õ i Ã

¯ > «

¯ ÝÌÕÀi

ä Îä ä {ä ä Èä

£ÎÓÓ Ó£ä{ ÎÎä£ ÎnÓ£

ÓÎ°È ÎÇ°È xn° Èn°Ó

Î{°È xx°£ nÈ°{ £ää°ä

ÎnÓ£

Èn°Ó

£ää°ä

ä ä ä £nä

/iÃÌÊ,i« ÀÌ\ ,nÓÎÓ ° -

n£ ÇÎ Èx x xÎ {Ç {Î Î Îx

Óä¯

Çä¯ Çä xä Îä £ä

ÇÈ Èx xÈ { {Î ÎÇ ÎÎ Ó ÓÈ

ÇÎ È{ xÇ x£ {x {ä ÎÈ ÎÓ Ó

ÇÎ ÈÎ xx {n {Ó ÎÇ ÎÎ Ó Óx

Çä ÈÎ xÇ xÓ {Ç {Î Î Îx ÎÓ

Çä ÈÓ xx { {{ Î Îx ÎÓ Ón

Çä È£ xÎ {Ç {Ó ÎÈ ÎÓ Ó Óx

Èn Èä xÓ {È {ä Îx Σ ÓÇ Ó{

Îä Óx ÓÇ ÓÎ

ÓÓ Óä

Ó Óx ÓÓ ÓÇ ÓÎ Óä

Ó£ £ Ê

ä x £ä £x Óä Óx Îä

, Ê- âiÊ­ Ì°® ÓäÊÝÊÓä ÎäÊÝÊÎä ÎäÊÝÊÈä ÈäÊÝÊÎä ÈäÊÝÊÈä

{x £Çä{ £Çä£ £ÈnÎ £Èxä £x Ç £x£

£{£n £Îää ££xn nn Ç x È£

£{äx £ÓÈä £än äÓ Ç£n xxä

£ÎxÇ ££ £äÎä nx{ ÈÇÇ xän

{ÈÓ ÎÎÓ ÓÎx

Î Î ÓÈ{ £Çx

ÎÈ ÓÇÓ Ó££

£ÈÇ £ÓÎ Èx ä

£Ó £äÇ Èä ä

£ÇÓ £ÎÓ ÇÓ ä

Îx {ä {x xä xx Èä Èx Çä Çx nä

/Þ « V > Ê 6 * Ê * i À V i Ì > } i à i } ÌÊ } n°x¿ £ä°ä¿ È£ È{ x{ xn {x {n xÈ Èä {È {

}Ê £Çä{ £È x £ÈÇ{ £ÈÎÇ £xnÎ £x££

i } ÌÊ VÀ Ãà n°x¿ £ä°ä¿ ÈÓ ÈÇ x{ x {{ {Ç xÇ È£ {x {n

nx ä

VÀ Ãà > £Çä{ £È £Ènx £ÈxÓ £x x £{ È

,ÊrÊ xn 9i>À ÞÊ ÃÌÊ vÊ£äää Õ i Ã]ÊÎäääÊ ÀÃÊ>Ì °änÊ 7 ÊrÊf{°£{

ORDERING INFORMATION Sample Number: 2GR8-232A-120V-EB81-U

G

R8

2

32

Width __=1' width

Number of Lamps 2 2=2 Lamps (Not Included)

Trim Type G=Grid/Lay-in (Standard)

Wattage 32=32W T8 (48")

Series R8=General Purpose 1 T8 Commercial Troffer

A

UNV

Shielding A=# 12 Acrylic Pattern A125=#12 Pattern Acrylic (.125" Thickness) Voltage 3 120V=120 Volt

L

EB

8

Ballast Type 3 EB=Electronic Instant Start

1

U

ER=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%

Options /PLUS=Higher Ballast Factor > 1.13. Total Harmonic Distortion < 20%

DLS=Digital Lighting System Dimming

FR=Fire Rated Label

Packaging U=Unit Pack

Lamp Size 8=T8 Number of Ballasts 1=1 Ballast 2=2 Ballast

277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-2774 Options GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps Installed Flex=Flex Installed Emergency=EM Installed

ACCESSORIES EQ = T-Bar Safety Earthquake Clips 1 FCS-XXW-U = Field Installed Flange Kit

Notes: 1

An EQ Grid Clip is recommended for all 9/16" ceiling systems.

2

Standard off-center ballast on 3 lamp fixtures.

3

Products also available in non-US voltage and freqeuncies for international markets

4

Not Available when specifying emergencies, voltage must be specific

SHIPPING INFORMATION

>Ì> }Ê ° ,n ÓÎÓ

Specifications and Dimensions subject to change without notice. Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

7Ì° £ Ê LðÊ

ADF031753 11/07/2007 2:05:51 PM


FIXTURE TYPE F7 MANUFACTURE: METALUX DESCRIPTION: SURFACE WRAP AROUND PART # WN 232A UNV EB81 LAMPS: T8 L8735 WEB SITE: www.cooperindustries.com FACTORY REP: Specified Lighting 317-577-8100 SUPPLIER: FD Lawrence 317-549-1100 Warranty on Ballast 5 Years from Ship Date 01-02-2011

RETURN SPECIFICATIONS


RETURN

COOPER LIGHTING - METALUX

®

DESCRIPTION

The WN Series is a specification wraparound luminaire featuring energy efficient performance. The luminaire's clean, low profile design is both appealing and functional. The WN Series utilizes a clear, low brightness, extruded acrylic refractor for high performance and aesthetics.

Type

Catalog #

F7

BMH Sleep Lab

Project

Date

Comments

The efficient and stylish WN Series is the perfect wraparound for schools, offices and other commercial and retail spaces.

Prepared by

EMD

S P E C I F I C AT I O N F E AT U R E S A…Construction

B…Electrical*

D…Lens

Housing consists of die formed cold rolled steel. Ends formed with the housing for strength and provisions for continuous row aligners. Steel end plates with 7/8" KO and light-seal embossment. Ballast cover easily removed without tools.

Ballasts are CBM/ETL Class "P" and are positively secured by mounting bolt. Rotor lock lampholders. UL/CUL listed. Suitable for damp locations.

100% clear acrylic prismatic lens. Sides have inside linear prisms and bottom has pyramidal prisms for low brightness control.

C…Finish

Multistage, prepaint ensures maximum bonding and rust prevention.

A

B

C

WN 217 228T8 232

D

6" [152mm]

2 ' , 4 ' O R 8 ' S U R FA C E T8 LAMPS

2-1/2" [63mm]

Commercial Wrap 7-5/8" [194mm]

L A M P C O N F I G U R AT I O N S

L E N S R E M O VA L

6" [152mm]

1

2-1/2" [63mm] 4-5/8" [117mm] 7-5/8" [194mm]

E N E R G Y D ATA Input Watts:

2

M O U N T I N G D ATA

EB Ballast & STD Lamps 217 (36) 228T8 (48) 232 (55)

92-1/2" [2349mm] 8'

1-13/16" [46mm]

90-7/8" [2309mm]

Luminaire Efficacy Rating LER = FW-80 Catalog Number: WN-232A

44-1/2" [1131mm] 42-15/16" [1090mm]

7-5/8" [194mm] 6" [152mm] 1-1/8" [29mm]

Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.00 3" [76mm] 4-1/2" [114mm]

Ceiling Stand-Off Embossments

LER = FW-93 Catalog Number: WN-228T8-HB1

41-3/8" [1051mm] 42-3/8" [1076mm]

Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.59

88-7/16" [2246mm] 90-7/16" [2297mm] 96" [2440mm]

4'

1-13/16" [46mm]

44-1/2" [1131mm] 42-15/16" [1090mm] Ceiling Stand-Off Ground Screw Bump Embossments

7-5/8" [194mm] 6" [152mm] 1-1/8" [29mm]

2'

1-13/16" [46mm]

1-1/8" [29mm]

7-5/8" [194mm] 6" [152mm] 3" [76mm] 4-1/2" [114mm] 40-7/16" [1027mm]

7/8" [22mm] K.O. (5)

42-7/16" [1078mm]

*Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements.

20-5/8" [523mm] 19" [483mm]

1" [25mm]

8-3/16" [208mm] 24" [610mm]

1" [25mm]

LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS

Safe and convenient means of disconnecting power.

48" [1219mm]

ADF081637 COOPER LIGHTING


WN T8

RETURN P H OTO M E T R I C S Candlepower WN-232-EB81-U Energy Saving Ballast Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

F32T8/35K lamps 3100 lumens Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.4 x mounting height Efficiency = 82.0% Test Report: 134P132 LER = FW-80 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.00

Along II 1583 1588 1580 1554 1512 1454 1380 1291 1181 1043 848 602 429 317 240 180 123 62 3

Candlepower WN-228T8-HB81-U Energy Saving Ballast Across ⊥ 1583 1591 1607 1618 1605 1563 1488 1375 1225 1030 809 626 512 444 409 390 369 347 332

45° 1583 1594 1597 1591 1573 1534 1473 1384 1258 1077 851 655 518 413 333 270 223 185 155

Coefficients of Utilization

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

95 82 72 64 57 51 46 42 38 35 32

95 79 67 57 50 44 39 35 31 28 26

95 76 62 52 45 39 34 30 27 24 22

92 83 76 69 64 59 54 50 47 44 41

92 80 70 62 55 49 45 41 37 34 31

92 76 65 56 49 43 38 34 31 28 26

92 73 61 51 44 38 33 29 26 24 22

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180

Lumens 1304 2152 3544 4441 645 5086

%Lamp 21.0 34.7 57.2 71.6 10.4 82.0

Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.4 x mounting height Efficiency = 90.2% Test Report: 134P133 LER = FW-93 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.59

Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

Along II 1562 1566 1558 1532 1490 1432 1358 1270 1162 1025 833 590 422 312 236 178 121 61 3

Across ⊥ 1562 1569 1586 1597 1586 1545 1472 1361 1214 1022 803 623 510 442 407 389 367 345 332

45° 1562 1572 1576 1570 1552 1514 1453 1365 1242 1063 841 648 512 408 328 267 221 184 152

Coefficients of Utilization

Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 95 86 79 72 66 61 57 52 49 46 43

F28T8 28W lamps 2800 lumens

%Fixture 25.6 42.3 69.7 87.3 12.7 100.0

20% 50% 50 30 10

30% 50 30 10

50

85 74 65 58 52 47 42 38 35 32 30

80 69 61 54 49 44 40 36 33 31 29

74 65 57 51 46 41 38 34 32 29 27

85 72 61 53 46 41 36 33 30 27 25

85 69 58 49 42 37 32 29 26 23 21

80 67 58 50 44 39 35 31 28 26 24

80 65 55 47 40 35 31 28 25 22 20

10% 30 10 74 63 54 47 42 37 33 30 27 25 23

74 61 52 45 39 34 30 27 24 22 20

0% 0 72 59 50 42 37 32 28 25 22 20 18

Ty p i c a l VC P Pe r c e n t a g e s Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60

Height Along 8.5’ 10.0’ 52 58 43 48 36 40 40 46 32 37

Height Across 8.5’ 10.0’ 44 53 31 39 15 21 35 42 17 22

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 105 95 87 79 73 67 62 58 54 50 47

105 91 79 70 62 56 50 46 42 38 35

105 105 87 83 73 68 63 57 55 49 48 42 43 37 38 33 34 29 31 26 29 24

101 91 83 76 70 64 60 55 52 48 45

101 87 77 68 60 54 49 45 41 37 35

101 84 71 61 53 47 42 37 34 31 28

101 81 66 56 48 42 36 32 29 26 24

20% 50% 50 30 10

30% 50 30 10

50

94 81 72 63 57 51 46 42 39 36 33

87 76 67 59 53 48 44 40 37 34 31

81 71 62 56 50 45 41 38 35 32 30

94 78 67 58 51 45 40 36 32 30 27

94 76 63 53 46 40 35 31 28 25 23

87 74 63 55 48 43 38 34 31 28 26

87 71 60 51 44 39 34 30 27 25 22

Zonal Lumen Summary

Ty p i c a l VC P Pe r c e n t a g e s

Zone 0-30 0-40 0-60 0-90 0-180

Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60

Lumens 1286 2124 3498 4389 5052

%Lamp 23.0 37.9 62.5 78.4 90.2

%Fixture 25.5 42.0 69.2 86.9 100.0

10% 30 10

Height Along 8.5’ 10.0’ 52 58 43 49 36 40 41 47 33 37

81 69 60 52 46 41 36 33 30 27 25

81 67 57 49 42 37 33 29 26 24 22

0% 0 78 65 54 46 40 35 31 27 25 22 20

Height Across 8.5’ 10.0’ 44 54 31 40 15 21 35 43 17 22

O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : W N - 2 3 2 A - U N V- E B 8 1 - U

Length Blank=2' or 4' Length 8T=8' (Tandem) Series(1) WN=Commercial Surface Wrap Number of Lamps (2) 2=2 Lamps (Not Included)

Wattage 17=17W T8 (24") 28T8=28W T8 (48")) ((6) 32=32W T8 (48")

Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 4) 120-277 ((4) Options GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (5)

Lamps Included

Lens A=Acrylic Refractor/Lens

Packaging Options Ballast Type (3) DEC=Decorative End Cap U=Unit Pack EB8 =T8 Electronic Instant Start. CRA=Continuous Row Total Harmonic Distortion < 10% Aligner No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. No. of Total Harmonic Distortion < 20% Ballast 1 or 2 ACCESSORIES REB1= T8 Electronic Instant Start Residential Ballast. SCF=Fixed Stem Set (Specify Length) ER8 =T8 Electronic Program Rapid Start. SCS=Swivel Stem Set (Specify Length) Total Harmonic Distortion < 10% SCA=Adjustable 48” Stem Set No. of Ballast WN-2LT-DEC-ENDS=Decorative End 1 or 2 Caps - 2 Lamps (2 pieces) ER8 /PLUS= T8 Electronic Program Start. WN-CRA=Continuous Row Aligner High Ballast Factor >1.13. (24 pieces) No. of Total Harmonic Distortion < 10% Ballast 1 or 2 HPT8 Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2

S H I P P I N G I N F O R M AT I O N (1)

(2)

NOTES: Steel endplates with 7/8" KO standard for continuous row mounting. 2 point suspension recommended for 2 and 4 lamp models. 3 point suspension (3) recommended for 8 foot tandems. Products also available in non-US voltage and freqeuncies for international markets. 120V must be specified with a residential (4) (5) ballast. Not Available when specifying emergencies, voltage must be specified. A low profile battery pack is required for installation with standard ballast cover (6) (consult Cooper Lighting). When utilizing 28W T8 lamps, HB Ballast must be specified. Other ballast restrictions may apply. Consult your Cooper Lighting Representative for availability and ordering information. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.

Catalog No.

Wt.

WN-217A WN-228T8A 8TWN-228T8A WN-232A 8TWN-232A

6 8 15 8 15

lbs. lbs. lbs. lbs. lbs.

Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801

12/09

ADF081637


FIXTURE TYPE F8 MANUFACTURE: METALUX DESCRIPTION: 2X2 STANDARD LENS PART # 2GR8 2BX40A-UNV-L8735-EB81 LAMPS: BX40 24” L8735 WEB SITE: www.cooperindustries.com FACTORY REP: Specified Lighting 317-577-8100 SUPPLIER: FD Lawrence 317-549-1100 Warranty on Ballast 5 Years from Ship Date 01-02-2011

RETURN SPECIFICATIONS


RETURN

BMH Sleep Lab EMD

F8


RETURN


FIXTURE TYPE H1 MANUFACTURE: LUMARK DESCRIPTION: OUTDOOR FLOOD LIGHT PART # MP MS K 150 120V LAMPS: MP150/U/MED WEB SITE: www.cooperindustries.com FACTORY REP: Specified Lighting 317-577-8100 SUPPLIER: FD Lawrence 317-549-1100 Warranty on Ballast 5 Years from Ship Date 01-02-2011

RETURN SPECIFICATIONS


RETURN

COOPER LIGHTING - LUMARK ®

DESCRIPTION

Impact Flood's cylindrical form blends effortlessly to architectural and landscape environments. Available in wattages up to 175W Metal Halide and High Pressure Sodium, and up to 42W Compact Fluorescent. Impact Flood offers properly scaled solutions for any floodlighting application.

Type

Catalog #

BMH Sleep Lab

Project

Date

Comments Prepared by

H1

EMD

S P E C I F I C AT I O N F E AT U R E S

Construction

Electrical

HOUSING: Rugged one-piece diecast aluminum housing will endure the toughest environments while maintaining precise tolerance control. Housing incorporates a one-piece extruded silicone gasket that seals the optical/electrical compartment from external moisture and contaminants. DOOR: Die-cast aluminum door features integral hinging to the housing. Door is secured with two (2) tamper resistant stainless steel allen head fasteners. Door frame features an integral accessory channel for the mounting of a wide array of optional vandal and light control accessories. The door lens is 0.2" thick, impact resistant, clear flat tempered glass sealed to the door with a one-piece silicone gasket.

ELECTRICAL COMPONENTS: High Power Factor (HPF) ballast components are strategically located and heat sunk to the housing for cooler operation and longer life. Optical

OPTICAL ASSEMBLY: Available in horizontal or vertical lamp orientations, high efficiency optical systems are formed from premium 95% reflective sheet aluminum. Optics feature medium-base lampholders. Mounting

Heavy-duty die-cast aluminum knuckle utilizes tooth-lock adjustment mechanism for both solid engagement and easy aiming adjustment. Knuckle adjustment is made via one (1) captive stainless

steel allen head fastener consistent with door frame fasteners. Knuckle tested to safely sustain 3G of vibration. Knuckle features a 3/4" NPT nipple for rigid attachment to available mounting accessories. Optional heavy-gauge adjustable steel trunnion mount provides additional durability when required. Finish

Fixture is finished in a 5 stage premium TGIC polyester powder coat paint, 2.5 mil nominal thickness for superior protection against fade and wear. Standard color is bronze. Optional white, black, and grey finishes are available.

MS IMPACT FLOOD SMALL 50 - 175W Pulse Start Metal Halide Metal Halide High Pressure Sodium

28 - 42W Compact Fluorescent

ARCHITECTURAL FLOOD LUMINAIRE

DIMENSIONS Knuckle Mount

Trunnion Mount

13-7/8" [352 mm]

12-5/8" [322 mm] T E C H N I C A L D ATA UL Wet Location Listed CSA Certified 25°C Maximum Ambient Temperature External Supply Wiring 60°C Minimum 15-1/8" [385 mm]

6-11/16" [171 mm]

DRILLING DIMENSIONS Trunnion Mount

3-1/8" [80mm]

LAMP TYPE

WATTAGE

Pulse Start Metal Halide (MP)

50, 70, 100, 150W

Metal Halide (MH)

175W

High Pressure Sodium (HP)

50, 70, 100, 150W

Compact Fluorescent (CF)

26, 32, 42W

1-9/16” [40mm]

7/16" Dia. [12mm]

17/32" Dia. [14mm]

E N E R G Y D ATA High Reactance Ballast Input Watts 50W HPS HPF (66 Watts) 50W MP HPF (72 Watts) 70W HPS HPF (91 Watts) 70W MP HPF (90 Watts) 100W HPS HPF (130 Watts) 100W MP HPF (129 Watts) 150W HPS HPF (188 Watts) 150W MP HPF (185 Watts) Electronic Ballast Input Watts 26W CF HPF (29 Watts) 32W CF HPF (36 Watts) 42W CF HPF (46 Watts) E P A (effected projected area) 1.12 S H I P P I N G D ATA (Approx.) Net Weight (lbs.): 25

C

ER

TEM

S

YS

D

6-11/16" [171 mm]

S

15-1/8" [385 mm]

TIFIE

ADH082292 pc 2010-09-14 10:49:32


RETURN

MS IMPACT FLOOD SMALL

P H OTO M E T R I C S 3

3

2

2 1

1 A BC D

3

2

1

0

1

E

2

0

3

1

2

2

3

1

0

MPMS-X-VF-150 150—Watt MP 14,000—Lumen Clear Lamp Vertical Flood

3

2

1

0

1

2

3

E 0.45 0.20 0.11

Footcandle Table Select mounting height and read across for footcandle values of each isofootcandle line. Distance in units of mounting height. Mounting Footcandle Values for Height Isofootcandle Lines A B C D 10' 11.25 4.50 2.25 1.13 15' 5.00 2.00 1.00 0.50 20' 2.80 1.12 0.56 0.28

E 0.45 0.20 0.11

3

MPMS-X-HF-150-XX-TV 150—Watt MP 14,000—Lumen Clear Lamp Horizontal Flood with Top Visor

A

2

0

1

MPMS-X-HF-150 150—Watt MP 14,000—Lumen Clear Lamp Horizontal Flood

3

A BCDE

Footcandle Table Select mounting height and read across for footcandle values of each isofootcandle line. Distance in units of mounting height. Mounting Footcandle Values for Height Isofootcandle Lines A B C D 10' 11.25 4.50 2.25 1.13 15' 5.00 2.00 1.00 0.50 20' 2.80 1.12 0.56 0.28

1

BCD E

2

3

3

2

2

1

1 A B CD E

0

3

0

1

1

2

2

3

3

2

1

0

1

2

3

3

HPMS-X-VF-150 150—Watt HP 16,000—Lumen Clear Lamp Vertical Flood

NOTE: Specifications and dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801

ADH082292 pc 2010-09-14 10:49:32

2010-09-14 13:09:47


RETURN

MS IMPACT FLOOD SMALL

ORDERING INFORMATION Sample Number: MHMS-K-HF-175-MT-LL

Lamp Type

1

=Pulse Pulse Start Metal MP= Halide

Mounting T=Trunnion

Distribution HF=Horizontal Flood

Voltage

K=Knuckle

VF=Vertical Flood

208V

MH=Metal Halide2 HP=High Pressure Sodium

Lamp Wattage

CF=Compact Fluorescent

MP

3

120V 240V

1

347V

50=50W 70=70W

Series =Impact Flood Small MS=Impact

277V 480V DT

100=100W =150W 150=150W

MT TT

MH

E

175=175W2

4

HP

Options Q=Quartz Restrike (Hot Strike Only) EM=Quartz Restrike with ''Delay Relay'' (Quartz lamp strikes at both hot and cold starts) EM/SC=Emergency Separate Circuit LL=Lamp Included (Must Specify Wattage with Fluorescent) PE=Internal Photocontrol (Specify Voltage) PC=Button Type Photocontrol F=Single Fuse (120, 277 or 347V. Specify Voltage) FF=Double Fuse (208, 240 or 480V. Specify Voltage)

50=50W 70=70W 100=100W

Accessories 6 MS/JB-XX=Architectural J-Box MS/SF-XX=Slipfitter MS/TMA-XX=Twin Mount Arm (EPA 0.35)

MS/WMA-XX=Wall Mount Arm (EPA 0.22) MS/WM-XX=Wall Mount MS/BD-XX=Barn Doors (EPA 1.03) MS/TV-XX=Top Visor (EPA 0.51) MS/4V-XX=Four-Sided Shield (EPA 0.87) MS/VS=Vandal Shield MS/WG=Wire Guard

Standard Color 5 __=Bronze (Standard)

150=150W

WH=White =Black BK=Black

CF

26=26W 32=32W

AP=Grey

42=42W Notes:

1 All HID lamps are medium-base. 2 175W MH available in non-U.S. markets only. 3 Products also available in non-US voltages and 50HZ for international markets. 4 Compact Fluorescent lamps only, 120-277V with internal fusing. In cold temperatures, compact fluorescent lamps produce lower illumination levels. 5 Other finish colors available. Consult your Cooper Lighting representative. 6 Order separately, replace XX with color specification.

STO C K S A M P L E N U M B E R ( L A M P I N C L U D E D ) : Sample Number: MPMS15

MP

MS

MP=Pulse Start Metal Halide

Series MS=Impact Flood Small

Lamp Wattage 70=70W 10=100W 15=150 W

NOTES: [stock]:

Accessories (order separately) MS/TV-BZ=Top Visor MS/4V-BZ=Four Sided Shield MS/BD-BZ=Barn Doors MS/WG=Wire Guard

Horizontal flood optics, knuckle mount, multi-tap ballast and bronze paint are standard for stock oproducts. Add “W” to the end of the catalog logic to specify white finish (available on small housing 150W only). Stock accessories only available in bronze finish. Options not available with stock products. Refer to standard ordering information. Refer to In-Stock Guide for availability.

VOLTAGE CHART DT=Dual-Tap

120/277 (wired 277V)

MT=Multi-Tap

120/208/240/277 (wired 277V)

TT=Triple-Tap

120/277/347 (wired 347V)

E=Electronic Ballast (CF only)

120-277V (wired 277V) (50/60 HZ)

NOTE: Specifications and dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801

ADH082292 pc 2010-09-14 10:49:32

2010-09-14 13:09:47


C AT A L O G # :

TYPE:

COOPER LIGHTING—LUMARK

®

DESCRIPTION

The Impact Flood Medium (MM) lower knuckle slip-fits over a standard 2" pipe size (2 3/8" O.D.) tenon. Impact MM can be mounted to the following accessories: Surface Mount Tenon (MM/SMT), Stanchion Mount Tenon (MM/ST), Twin Mount Tenon (MM/TMT), and Wall Mount Tenon (MM/WMT).

RETURN

A C C E S S O R I E S S P E C I F I C AT I O N S

S U R FA C E M O U N T T E N O N [ M M / S M T ] For above-grade surface mount placement, the MM/SMT is supplied with a 4" tall standard 2" pipe size (2 3/8" O.D.) tenon. S TA N C H I O N M O U N T T E N O N [ M M / S T ] Used to mount fixture above grade to solid surface, or partially buried when secured to concrete pad. Cast aluminum housing and mounting plate is 18" tall and is supplied with a standard 2" pipe size (2 3/8" O.D.) tenon.

5/16" Dia. [8 mm]

4" [102 mm]

6 1/2" [166 mm] Sq.

MM IMPACT FLOOD MEDIUM ACCESSORIES

5" [127 mm] Sq. Bolt Pattern TM

Surface Mount Tenon [MM/SMT]

TWIN MOUNT TENON [MM/TMT] Soft form extruded aluminum arm is 42" in length and features two (2) standard 2" pipe size (2 3/8" O.D.) tenons for twin fixture mount. Other lengths and drilling patterns available upon request. Twin arm base slip fits over standard 2" pipe size (2 3/8" O.D.) tenon. End caps are removable for wiring access. Useful in ground mount and pole mount applications.

4" [102mm]

5/16" [8 mm] Dia.

WA L L M O U N T T E N O N [ M M / W M T ] Extruded aluminum arm with cast mounting plate is 15" in length and is supplied with a standard 2" pipe size (2 3/8" O.D.) tenon. Also useful as an arm extension off square area light pole.

18" [457 mm]

6" [152 mm] Sq. Bolt Pattern

Stanchion Mount Tenon [MM/ST]

4" [102 mm]

42" [1067 mm]

2 3/8" [60 mm] O.D.

Twin Mount Tenon [MM/TMT]

4" [102 mm] 6 1/2" [165 mm]

AIMING RANGE

5" [127 mm] Sq. Bolt Pattern

15" [381 mm]

180°

ER

T EM

D

ADH051417

C

COOPER LIGHTING

YS

S

S

Wall Mount Tenon [MM/WMT]

TIFIE


RETURN

M M I M PA C T F L O O D M E D I U M A C C E S S O R I E S

A C C E S S O R I E S S P E C I F I C AT I O N S ( C O N ’ T. )

4-SIDED SHIELD [MM/4V] Controls lamp glare and spill light in all directions. Useful when aiming direction or intended target lies in close proximity to pedestrian and/or motor vehicle activity. Mounts to accessory channel in doorframe. Compatible with all distributions (EPA 2.21). BARN DOORS [MM/BD] Four (4) independently mounted and adjustable doors control cutoff angles in all directions, allowing custom distribution control for any application. Mounts to accessory channel in door frame. Compatible with all distributions (EPA 2.49).

4-Sided Shield [MM/4V]

TO P V I S O R [ M M / T V ] Controls excess spill and glare on top portion of distribution. Especially useful in uplighting applications to limit light travel above intended wall surface or sign. Mounts to accessory channel in doorframe. Compatible with all distributions (EPA 1.3). VA N DA L S H I E L D [ M M / V S ] 3/16" thick molded polycarbonate convex lens. Treated with UV inhibitor to discourage the gradual discoloration that results from exposure to sunlight and metal halide lamps. Compatible with all distributions. W I R E G UA R D [ M M / W G ] Heavy-gauge corrosion resistant wire guard with silver polyester powder coat finish provides protection for glass from projected objects. Compatible with all distributions.

Barn Doors [MM/BD]

Top Visor [MM/TV]

Wire Guard [MM/WG]

Vandal Shield [MM/VS]

NOTE: Specifications and dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801

ADH051417


FIXTURE TYPE H2 MANUFACTURE: RAB DESCRIPTION: FLUORESENT WALL PACK PART # WPTF26 LAMPS: 26W TRIPLE LAMP BASE GX24q-3 WEB SITE: www.rabweb.com SUPPLIER: All Phase Electric 765-282-2259 Warranty 1 Year from Ship Date 01-02-2011

RETURN SPECIFICATIONS


RETURN JOB NAME: DATE: TYPE:

WPTF26 DESCRIPTION Compact Fluorescent Tallpack. Vandal resistant polycarbonate housing. Heavy die-cast aluminum back plate with 1/2" bottom and back conduit knockout. Factory installed photocontrol optional. Lamp supplied.

SPECIFICATIONS

DIMENSIONS

Back Plate: Heavy die cast aluminum. 1/2" bottom conduit knockout. Knockouts for mounting to 3" or 4" junction boxes Ballast Housing: Stamped steel painted white Reflector: Die formed aluminum for wide light distribution. Moveable Glare Shield for field adjustable light control slanted slightly downward for more light on the job UL Listing: Suitable for wet locations

Ballast Minimum Starting Temperature: 0° F Housing and Refractor: Vandal resistant polycarbonate molded refractor. Die cast aluminum back plate Patents: The unique RAB Tallpack is protected by U.S. Patent D569,029; China Patent ZL200730149211.2; Taiwan Patent D124,864 and Canada Patent D121,993 Color: Bronze Weight: 4.5

PHOTOMETRIC

ORDERING INFORMATION Compact Fluorescent Lamp supplied with fixture

Total Watts 26

Factory Installed Options Add suffix to Catalog Number

Lamp Type 26W Triple

Lamp Base

Ballast

GX24q-3 Elec HPF QT

Tamperproof screws (/TP) Swivel Photocontrol (/PCS) Single fusing for 120 and 277 volt (/F)

Starting Amps/ Operating Amps 120V 208V 240V 277V 0.24

0.2

0.18

0.11

Input Watts 29

LAMP Initial ANSI Lumens 1800

Lamp Hours 12000

Double fusing for 208 and 240 volt (/FF) Button Photocontrol (/PC)

Note: Specifications may change without notice

RAB Lighting, Inc. • 170 Ludlow Ave• Northvale, NJ 07647 • Tel: 888 RAB-1000 • Fax: 888 RAB-1232 • www.rabweb.com © 2011 RAB Lighting, Inc.


READ AND SAVE THESE INSTRUCTIONS RETURN

TYPE K CF700BS

Model No.

CF700AW07 CF700WW07 CF700AB07 CF700PB07 CF700PBW07 Net Weight:

CF700WPB07 CF700BS07 CF700WB07 CF700OB07 CF700CK07 13.7

Lbs.

BUILDER Series Ceiling Fan Owner's Manual Part No. F40BP71810009

Form No. BP7181-9


RETURN

!

WARNING

WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. 3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing. 4. Do not put anything into the fan blades while they are turning. 5. Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation 1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades. 2. All wiring must satisfy National and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician. 3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt. 4. The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling. 5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades. 6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician. WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan. WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use this product by Emerson Company could result in personal injury or property damage. WARNING: To Reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

Tools Required Standard screwdriver Phillips screwdriver

!

!

Wire stripper Step ladder

WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Company. Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage.

WARNING

Do not install or use fan if any part is damaged or missing. Call Toll-Free:

1-800-654-3545

!

WARNING

If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.

2


RETURN

General

After opening the box you should find the following parts: • One motor housing assembly • One upper canopy • One set of blade flanges • One hanger bracket • One downrod/hanger ball assembly • Parts bag • One set of blades • One switch housing cover • One Owner's Manual

Installation Instructions !

WARNING

The fan must be hung with at least 7' of clearance from floor to blades.

1. If your fan is to replace an existing ceiling light fixtures, turn electricity off at the main fuse box at this time and remove the existing light fixture. !

WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local Codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

!

WARNING

To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt. !

WARNING

The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support”. 2. Install hanger bracket (item 1) to outlet box using the two screws supplied with the outlet box. Hanger bracket must seat firmly against outlet box. Remove wall board if necessary until bracket contacts box. !

WARNING

Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.

4. The fan is supplied with a hanger ball/downrod assembly. Slide the downrod (Item 3) into motor mount adapter until the hole in the downrod aligns with the cross hole in the adapter. (Make sure wires do not twist during this step.) Next, insert clevis pin through cross holes in adapter and downrod. Install hairpin clip in hole in clevis pin. Now tighten the downrod setscrews securely to the downrod. !

WARNING

It is critical that the clevis pin in the motor mount adapter is properly installed and the setscrews securely tightened. Failure to verify that the clevis pin and setscrews are properly installed could result in the fan falling. 5. To attach switch housing (item 5) align the color stripes of connectors. Slide the connectors together until plastic latch on connector snaps over the tab on connector. Carefully tuck all wires and splices into the switch housing. Position switch housing (item 5) on plate and align the holes in the switch housing by installing the three screws in the side of plate. NOTE: To install an accessory light kit, remove switch housing (item 5) and make light kit electrical connections to blue and white leads marked “For Light” in the switch housing. Follow light kit instructions for wiring and installation. Then reinstall switch housing as outlined above. 6. Lift the fan, without blades, and put the downrod assembly into the hanger bracket. Make sure to engage the groove on the hanger ball (item 2) with the tab on the hanger bracket (item 1) to prevent rotation. !

WARNING

Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard. !

WARNING

To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket. WIRING THE FAN. If you do not have enough electrical experience, have your fan installed by a licensed electrician. NOTE: This fan comes with 80” long electrical leads. Before installing the fan, measure approximately 6 to 9 inches above the hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads. !

WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

3. Run the downrod (item 3) through the ceiling cover (item 4). Run the three wires from the fan through the downrod.

3


RETURN

7. Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation). Securely connect wires with wire connectors supplied. Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied. Securely connect the fan motor black wire and the blue wire to the supply black (hot) wire using wire connector supplied. After connections have been made, separate the white and green leads from the black and blue leads. Carefully turn the leads upward and push the green and white leads into one side of the outlet box. Then push the black and blue leads into the other side of the outlet box. !

Do not use water when cleaning you fan, as it could damage the motor or blades and create the possibility of an electrical shock.

!

WARNING

To reduce the risk of fire or electrical shock, do not use the fan with any solid-state speed control device.

WARNING

!

WARNING

Any control not specifically approved for this fan could result in fire, shock, and personal injury.

Remove rubber packing grommets from the motor and discard. They are for shipping protection only.

10. Attach the five blades (item 6) to their blade flanges (item 7) using the 3/16-24 x 5/16� screws provided. !

WARNING

Emerson SW95 Speed Control can be used with this fan.

To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling. 9.

!

Accessories

Attach the ceiling cover (item 4) to the hanger bracket (item 1) using the two canopy setscrews. !

Do not use abrasive cleaners which may cut through the protective lacquer and possibly damage the finish, use only a soft brush or lint free cloth to avoid scratching finish. Do not use water when cleaning you fan, as it could damage the motor or blades and create the possibility of an electrical shock.

WARNING

Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result. 8.

Maintenance 1.

!

WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Company. Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or properly damage.

WARNING

To reduce the risk of personal injury, do not bend the blade flanges when installing the flanges, balancing the blades, or cleaning the fan. Do not insert foreign objects between rotating fan blades. 11. Attach the blades to the fan motor with the ten 1/4-20 x 1/2� screws. Tighten the blades securely to the motor. Failure to securely tighten the blades could result in fan wobble. Attach the ball and chain to the pull chain. 12. Turn on the electricity. Check to see that the fan forward and reverse speeds work properly. Use the pull chain switch to cycle through the three fan speed, plus off. Use the reversing slide switch on the switch housing to change fan direction. Make sure blades come to a complete stop before changing fan direction. Installation is now complete.

4


! WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.

RETURN TROUBLE 1. Fan will not start.

Trouble Shooting PROBABLE CAUSE

SUGGESTED REMEDY

1. Fuse or circuit breaker blown. 2. Loose power line connections to the fan, or loose switch wire connections in the switch housing.

turned 3. Reversing switch in neutral position. 2. Fan sounds noisy.

1. Blades not attached to fan. 2. Loose screws in motor housing. 3. Screws securing fan blade holders to motor are loose. 4. Wire connectors inside switch housing rattling.

turned 3. Fan wobbles or shakes excessively.

1. Check main and branch circuit fuses or circuit breakers. 2. Check line wire connections to fan and switch wire connections in switch housing. ! WARNING: Make sure main power is off. 3. Make sure reversing switch position is all the way to one side. 1. Attach blades to fan before operating. 2. Check to make sure all screws in motor housing are snug (not over-tight). 3. Check to make sure the screws which attach the fan blade holders to the motor are tight. 4. Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing. ! WARNING: Make sure main power is off.

1. Setscrew in motor mount adapter is loose.

1. Tighten setscrew in motor mount adapter.

2. Setscrew in hanger ball/downrod assembly is loose.

2. Tighten the setscrew in the hanger ball/ downrod assembly.

3. Screws securing fan blade flanges to motor are loose. 4. Fan blade flanges are not seated properly.

3. Check to be sure screws which attach the fan blade flanges to the motor are tight. 4. Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor. If flanges are seated incorrectly, loosen the holder screws and retighten. 5. Tighten the hanger bracket screws to the outlet box, and/or secure outlet box. 6. Interchanging an adjacent (side-by-side) blade pair can redistribute the weight and result in smoother operation.

5. Hanger bracket and/or ceiling outlet box is not securely fastened. 6. Fan blades are out of balance.

5


Repair Parts

RETURN

GREEN GROUND WIRE

(8) SREWS (SUPPLIED WITH OUTLET BOX)

(1) HANGER BRACKET GREEN GROUND WIRE

TAB

GROOVE

(2) HANGER BALL

(8) CEILING COVER SETSCREW (2 PCS)

(4) CEILING COVER

(3) DOWNROD

(8) HAIRPIN

(8) CLEVIS PIN

MOTOR MOUNT ADAPTER

(8) DOWNROD SETSCREW

MOTOR HOUSING

(8) SCREW (15 PCS)

(6) BLADE (5 PCS)

SWITCH HOUSING PLATE COLOR CODED MOTOR CONNECTOR (7) BLADE HOLDERS (5 PCS)

(9) WIRING HARNESS (8) SCREW (3 PCS) REVERSE SWITCH

(8) LOCKWASHER (10 PCS) (8) SCREW (10 PCS) COLOR CODED SWITCH HOUSING CONNECTOR

(5) SWITCH HOUSING

ON/OFF 3-SPEED PULL CHAIN (8) BALL AND CHAIN

6


Ceiling Cover

Switch Housing

Blade Assembly (set of 5)

Blade Flanges (set of 5)

Loose Parts Bag Containing: Blade Hardware Clevis Pin and Hairpin Pull Chain Ball Ceiling Cover Hardware Wire Connectors

Wiring Harness

Owner’s Manual

4

5

6

7

8

9

1 2 3

Hanger Ball Assembly, Consisting of: Hanger Bracket Hanger Ball Downrod

DESCRIPTION

*

KEY NO.

7 BP7181-9

BP7181-9

761592-3

— — — — —

761870-1

761601-1

761599-6

760321-2

760169-28

— — —

760750-1

CF700PB07

BP7181-9

761592-4

— — — — —

761870

761601

761599-6

760321-1

760169-29

— — —

760750

CF700AB07

BP7181-9

761592-3

— — — — —

761870-1

761601-1

761599

760321-2

760169-28

— — —

760750-1

BP7181-9

761592-3

— — — — —

761870-1

761601-4

761599-8

760321-28

760169-37

— — —

760750-41

MODEL NUMBER CF700PBW07 CF700AW07

HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION • NAME OF ITEM • MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing. For repair parts, phone 1-800-654-3545.

BP7181-9

761592-4

— — — — —

761870

761601-5

761599-9

760321-29

760169-36

— — —

760750-39

BP7181-9

761592-5

— — — — —

761870-2

761601-6

761599-10

760321-16

760169-38

— — —

760750-24

CF700WB07 CF700BS07

Before discarding packaging material, be certain all parts have been removed.

BP7181-9

761592-5

— — — — —

— — — — — 761592-3

761870-2

761601-2

761599-7

760321-4

760169-27

— — —

760750-3

CF700WW07

761870-1

761601-1

761599-7

760321-4

760169-27

— — —

760750-3

CF700WPB07

Repair Parts Listing

BP7181-9

761592-4

— — — — —

761870

761601-7

761599-11

760321-23

760169-39

— — —

760750-36

CF700OB07

BP7181-9

761592-5

— — — — —

761870-2

761601-8

761599-12

760321-30

760169-40

— — —

760750-43

CF700CK07

RETURN


RETURN

LIMITED WARRANTY

What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for fifteen years from the date you purchased your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR. What Will Emerson Company Do To Correct Problems: Emerson Company will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan. We will ship the repaired product or replacement to you at no charge, but you are responsible for all costs or removal, reinstallation and shipping of the product to Emerson Company. How Can You Get Service: YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center. • To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request. • To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center. You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage. What Is Not Covered: The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures caused by: • Repairs by persons not authorized by Emerson Company, • Use of parts or accessories not authorized by Emerson Company, • Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or • Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear. Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when: • The original purchaser or user ceases to own the product, or • The fan is moved from its original point of installation. This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Company. REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly. How State Law Relates To The Warranty: Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W. Florissant ¥ St. Louis, MO 63136 Part No. F40BP71810009

07/04 Printed in Taiwan

Form No. BP7181-9


FIXTURE TYPE L1 MANUFACTURE: ALL PRO DESCRIPTION: FLUORESENT CAN LIGHT SHOWER PART # CAN EI2072AT TRIM ERT724 LAMPS: 26 WATT PL WEB SITE: www.cooperindustries.com FACTORY REP: Specified Lighting 317-577-8100 SUPPLIER: FD Lawrence 317-549-1100 Warranty on Ballast 5 Years from Ship Date 01-02-2011

RETURN SPECIFICATIONS


ALL-PRO

RETURN

DESCRIPTION

The EI2072AT is designed for use in insulated ceilings and can be in direct contact with ceiling insulation. This AIRTITE™ housing prevents air flow between attic and living areas. The 26W electronic compact fluorescent ballast meets Energy Star requirements including FCC Title 47 CFR part 18 for consumer equipment. The EI2072AT offers trim types including reflector and lensed trims. The EI2072AT is covered under a 2 year Energy Star Limited Warranty.

Type

Catalog # Project

L1

BMH Sleep Lab

Date

Comments Prepared by

EMD

SPECIFICATION FEATURES

A ...H o u s i n g

Single wall aluminum housing. Openings are gasketed for AIRTITE installation. Housing height allows use in 2” x 8” joist construction. Housing adjusts for ceilings up to 1-1/8” thick. AIRTITE ceiling-to-housing installation gasket included. B ...P l a s t e r F r a m e

Includes regressed locking screw for hanger bars and cutouts for crimping hanger bars in position. C ...J u n c t i o n

Box

• UL listed for thorough branch wiring. • Positioned to accommodate straight conduit runs. • Seven conduit knockouts are uniform 1/2” size with true pryout slots. • Four pryouts with integral strain relief simplify non-metallic sheathed cable installation. D ...B a r H a n g e r s

Bar Hanger features include • Pre-installed nail. • Mini leveling foot aligns the housing to the bottom of the joist. • Housing can be positioned at any point within 24” joist spans • Score lines allow tool-free shortening for narrow joist spacing.

• Bar hangers may be repositioned 90° on plaster frame • Integral T-bar clip snaps onto T-bars – no additional clips are required E ...S o c k e t

G24q-3/GX28-3 socket for one 26W DTT*- Double Twin Tube (Quad) or 26W TTT -Triple twin Tube 4-pin lamp F ...L a m p

Compact Fluorescent Lamp (by others) 26 watt lamp generic designations: DTT-Double Twin Tube (Quad)(CFQ) • CFQ26W/G24q 2700K, 3000K, 3500K, 4100K TTT-Triple Twin tube (CFTR) • CFTR26W/GX24q 2700K, 3000K, 3500K, 4100K • Up to 12,000 hr rated average life • 82CRI rated lamps provide excellent color and high visual comfort. • Color temperature (warm to cool) options offer 2700K warm, 3000K, 3500K medium warm and 4100K cool incandescent-like light. G ...E l e c t r o n i c B a l l a s t

Models are provided with Energy Star Qualified and Title 24 compliant electronic fluorescent ballast. The ballast is rated for

use with 26W Double Twin Tube or Triple Twin Tube lamps (Triple Twin Tube is preferred for best visual comfort). Ballast is a high frequency electronic type that operates lamps above 40 kHz. In addition the ballast is thermally protected and end of life feature shuts down the ballast upon lamp failure with auto restart to eliminate need to reset power after lamp replacement. Meets FCC EMI/RFI Consumer Level Limits.

6" Insulated Ceiling

Labels

• UL/cUL Listed for Damp Location • UL/cUL Listed for Feed Through • UL/cUL Listed for Direct Contact with Insulation and combustible material Compliance

Meets following restricted air flow and IC requirements: • Washington State Energy Code • State of California Title 24 High Efficacy Luminaire • International Energy Conservation Code • New York State Energy Conservation Construction Code • Certified AIRTITE under ASTME283

C

AIRTITE Recessed Housing 26 Watt Compact Fluorescent

6” TRIMS FOR USE IN INSULATED CEILINGS FOR DIRECT CONTACT WITH INSULATION

Rated Lamp Watts: 26W (CFQ26WG238 Voltage: 120V-60Hz Input current: 0.40 Amps Input (Full) Power (ANSI watts): 24

EMI: FCC Title 47 CFR Part 18 (Class B) Consumer compliant for EMI (conducted and radiated) Sound rating: A Power Factor: 0.54 Ballast factor: .90 Max. THD: 150% Min. Starting Temperature: 0°F/-18°C Crest Factor: <1.7

7" [178mm]

F

Compact Fluorescent

Energy Data

Top View

A E

EI2072AT

G

B

7-1/2" [191mm]

D 1/2" [13mm] 6-1/2" [165mm]

10-1/2" [267mm]

California Title 24 Compliant

Ordering Information and 2 year limited warranty information on reverse

COOPER LIGHTING

11/08 ADV082456


EI2072AT

RETURN TRIMS ORDERING INFORMATION SAMPLE NUMBER: EI2072AT-ERT770TS Order housing, trim and accessories separately.

Housing

2 YEAR PRODUCT WARRANTY Energy Star Labeled Recessed Lighting EI2072AT=Insulated Ceiling 26W Compact Fluorescent AIR-TITE Housing

Trims

ERT770

Specular and Matte (Haze) Reflectors, Gloss White Trim Ring, Torsion Springs 26W DTT, 26W TTT Compact Fluorescent ERT770TS=Clear Specular Reflector ERT770MTS=Matte (Haze) Reflector OD: 7-1/4" (184mm)

ERT771

Gloss White Reflector with Torsion Springs 26W DTT, 26W TTT Compact Fluorescent ERT771TS=Gloss White Reflector OD: 7-1/4" (184mm) Metal Baffle with Torsion Springs 26W DTT, 26W TTT Compact Fluorescent ET772TS=Black Baffle, Gloss White Upper Reflector, Gloss White Trim Ring

ERT772

ET772WHTTS=Gloss White Baffle, Gloss White Upper Reflector, Gloss White Trim Ring OD: 7-1/4" (184mm)

ERT724

Drop Opal Lens 26W DTT, 26W TTT Compact Fluorescent ERT724=Wet location listed Shower Light with Drop Opal Lens and White Trim Ring OD: 8" (203mm)

Cooper Lighting (The Company) warrants this product ("the product") against defects in material or workmanship for a period of two years from date of original purchase, and agrees to repair or, at the company's option, replace a defective product without charge for either replacement parts or labor during such time. This does not include labor to remove or install fixtures. This warranty is extended only to the original purchaser of the product. A purchasers receipt or other proof of date of original purchase acceptable to the Company is required before warranty performance shall be rendered. This warranty only covers product failure due to defects in materials or workmanship which occurs in normal use. It does not cover the bulb or failure of product caused by accident, misuse, abuse, lack of reasonable care, alteration, or faulty installation, subjecting the product to any but the specified electrical service or any other failure not resulting from defects in materials or workmanship. Damage to the product caused by separately purchased, non-Company supplied components or bulbs, and corrosion or discoloration of components are not covered by this warranty. There are no express warranties except as described above. THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THE PRODUCT OR ARISING OUT OF ANY BREACH OF THIS WARRANTY. ALL IMPLIED WARRANTIES, IF ANY, INCLUDING IMPLIED WARRANTS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE DURATION OF THIS EXPRESS WARRANTY. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitations on how long an implied warranty lasts, so the above exclusions or limitations may not apply to you. No other warranty, written or verbal, is authorized by the Company. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To obtain warranty service, please write to Cooper Lighting, 1121 Highway 74 South, Peachtree City Georgia 30269. Enclose product model number and problems you are experiencing, along with address and telephone number. You will then be contacted with a solution or a Return Goods Authorization number and full instructions for returning the product. All returned products must be accompanied by a Return Goods Authorization Number issued by the Company and must be returned freight prepaid. Any product received without a Return Goods Authorization Number from the Company will be refused. Cooper Lighting is not responsible for merchandise damaged in transit. Repaired or replaced products shall be subject to the terms of this warranty and are inspected when packed. Evident or concealed damage that is made in transit should be reported at once to the carrier making the delivery and a claim filed with them.

Accessories

Gasket Kit GA-ATH7-6PK= AIRTITE Finished Ceiling Gasket Kit, 6 pieces (Seals ceiling cut-out irregularities) Oversise Trim Rings For use when ceiling opening is cut too large. Fits behind trim flange OT400P= 9-1/4” OD White Metal OT403P= 8” OD White plastic

Note: Specifications and Dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049


FIXTURE TYPE L3 MANUFACTURE: HALO DESCRIPTION: INCANDESENT CAN PART # CAN H7ICT TRIM 30CAT LAMPS: 75 WATT PAR 30 HALOGEN LONG NECK WEB SITE: www.cooperindustries.com FACTORY REP: Specified Lighting 317-577-8100 SUPPLIER: FD Lawrence 317-549-1100 Warranty on Ballast 5 Years from Ship Date 01-02-2011

RETURN SPECIFICATIONS


RETURN BMH Sleep Lab EMD

30CAT

L3


RETURN


FIXTURE TYPE L4 MANUFACTURE: PORTFOLIO DESCRIPTION: TRACK LIGHT PART # EC1475SBA LAMPS: GU10-16 50WATT WEB SITE: www.lowes.com

RETURN


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.