Remanufacturing the Lexmark MS/MX Series Toner and Drum Cartridges 5) Remove chip holder and chip. See Figure 13
Continued
end cap and three screws. See Figure 16 9) Fill the hopper with the appropriate load of toner to match the chip you installed. Replace the fill plug. See Figure 17
Figure 19 Figure 13 6) Replace the chip in the chip holder. See Figure 14 Figure 17 10) Install the end cap and three screws. See Figure 18
Figure 20
Figure 14 7) Install the chip holder and two screws. See Figure 15
Figure 18
OPC (Drum) cartridge instructions: Figure 21
Figure 15 8) On the large cartridge; Install the chip 1) Remove the two screws from both sides of the handle. See Figures 19 & 20 2) Pull the edge of the frame out slightly and remove the handle. See Figure 21. 3) Remove the developer assembly. See Figure 22
Figure 16
52
www.rechargeasia.com
4) With a small Phillips jeweler’s screwdriver, remove the drum axle pin screw. See Figure 23
Figure 22 5) Remove the axle pin. See Figure 24 6) With a small pair of needle nose pliers, turn the locking ring until loose. Pry the drive gear and ring from the drum axle shaft. See Figures 25, 26 & 27 7) Remove the drum. See Figure 28 8) Remove the PCR and both PCR