1 minute read
Vibrators
■ Aids the flow of dry materials ■ Produces blows of high intensity but low frequency ■ Can be mounted in any position ■ Explosion proof controls are available
Equipment
Advertisement
Solenoid control valves with adequate orifice openings must be used to ensure full starting force even at low regulator settings.
For vibrators with 1/4” inlets, use a solenoid valve with a minimum orifice of 3/16” diameter. Use 3/8” O.D. flex-tubing not to exceed 12’ in length from the operating valve.
For vibrators with 3/8” inlets, use a solenoid valve with a minimum orifice of 1/4” diameter. Use 1/2” O.D. flex-tubing not to exceed 12’ in length from the operating valve.
For vibrators with 1/2” inlets, use a solenoid valve with a minimum orifice of 3/8” diameter. Use 5/8” O.D. flex-tubing not to exceed 12’ in length from the operating valve. All vibrators must be installed with an inline filter, regulator, and lubricator.
Model
BH1 BH1-1/4 BH1-5/8 BH2 BH3S BH3L BH4 HCP3 HCP4
Weight (lbs.)
3 8 18 20 50
Hopper / Bin Dimensions (inches) Inlet NPT Mounting Centers Bolt SCFM Cap. Cu. Ft. Thk. In. Height Length Width Qty. Dia. 3 1/8 3-3/4 4-1/2 2 1/4 3-1/2 2 1/2 3.3
7 1/8 5-5/8 6 2-1/2 1/4 4-1/2 2 1/2 4.2
20 1/4 7-1/4 9 3-1/4 1/4 50 1/4 7-1/4 9-1/2 3-1/4 1/4 10 ton + 3/8 9-1/2 10-1/2 5 3/8 7-1/2 2 5/8 7.5 7-1/2 2 5/8 8.3 7-3/4 x 3-1/4 4 7/8 11.6
64 105 20 ton + 3/8 12 10-1/2 5 3/8 50 ton + 1/2 11-3/4 14-1/2 6-1/2 1/2
7-3/4 x 3-1/4 4 7/8 14.0 4 x 12 4 1 18.2 68 Hopper Car -- 14-1/4 -- 8 3/8 Dovetail Bracket -- -- 11.0 115 Hopper Car -- 16-3/4 -- 8 1/2 Dovetail Bracket -- -- 18.0