pqrg_2010-v1.0-low

Page 1

Product Quick Reference Guide 2010

www.infortrend.com


Table of Contents EonStor DS Data Services

1

Fibre RAID Fibre to Fibre Head Fibre to Fibre RAID Subsystem Fibre to SAS/SATA RAID Subsystem 4G Fibre to 2.5” SAS/SATA RAID Subsystem 2.5” SAS/SATA JBOD

2 3 4 9 10

SAS RAID SAS to SAS/SATA RAID Subsystem iSCSI to SAS RAID Subsystem SAS JBOD SAS to SATA RAID Subsystem

11 12 13 15

Connection Topology High Capacity Guide

16

Shipping Reference & Rackmount Kits Shipping and Rack Planning Reference Rackmount Guide

22 23

SANWatch Overview

24

Warranty & Quality

25

©2010 by Infortrend Technology, Inc. All rights reserved. * Any information provided herein is without warranties of any kind and is subject to change by Infortrend without prior notice. * Infortrend offers a 3-year limited warranty on systems. * Infortrend and the Infortrend logo are registered trademarks of Infortrend Technology, Inc. * ESVA and SANWatch are registered trademarks of Infortrend Technology, Inc. * All other names, brands, products, or services are trademarks or registered trademarks of their respective owners.


EonStor DS - Data Services EonStor DS is designed to support critical applications for small and medium businesses. It features redundant, hot-swappable hardware components, CacheSafe technology and full RAID protection to deliver high fault-tolerant capability. To protect data from even more critical threats, Infortrend allows users to enable snapshot and volume copy/mirror functions on their EonStor DS. By configuring the scheduler in SANWatch, users can automate data protection tasks, such as snapshot-taking, data copying and source/target synchronizing. In case of human errors or data volume failure, the differential and full copies for critical data sets can be leveraged to quickly recover data and restart services. SNAPSHOT • Copy-on-write technology to create point-in-time differential copies without disrupting online applications • Restore deleted files or rolling data volume back in seconds based on space-saving recovery points VOLUME COPY/MIRROR • Create independent point-in-time and mirrored full data copies without downtime • Allow production data to be immediately shared by secondary applications, such as testing, data mining and tape back-up • Restart service in minutes with minimized data loss when the source data volume fatally fail

Specifications Snapshot Maximum Number of Snapshot Images for a Source Volume Maximum Number of Snapshot Images in a System

256 4,000

Volume Copy/Mirror Maximum Number of Source Volumes in a System

16

Maximum Number of Replication Pairs for a Source Volume

4

Maximum Number of Replication Pairs in a System

64

Subsystem Overview

4U 3U

F16F-R4840 F16F-S4840 F16F-R4031-6/4 F16F-S4031-6/4

S24F-R1840-4

S24F-R2840-4

S24F-R1440

S24F-G1840-4

S24F-G2840-4

S24F-G1440

S16F-R1840-4

S16F-R2840-4

S16F-R1440

S16F-G1840-4

S16F-G2840-4

S16F-G1440

S12F-R1840-4

S12F-R2840-4

S12F-G1842-4

S12F-G2840-4

S12F-R1440

2U 1U

S12F-G1440 S12F-G1433

FF-R4031-6 FF-S4031-6

FC-FC

B12F-R1430 B12F-G1431

8G FC-3G SAS

8G FC-6G SAS

4G FC-3G SAS

* Models may vary by regions. 1

S16S-R1030 S16S-G1030 S16S-J1000-R S16S-J1000-S S12S-R1032 S12S-G1033 S12S-J1002-R S12S-J1000-S

S16S-J2000-R

S16E-R1130

S16S-J2000-S

S16E-G1130

S12S-J2000-R

S12E-G1133

S12S-J2000-G

S12E-R1132

6G SAS-6G SAS

iSCSI- 3G SAS

B12S-R1030 B12S-G1031 B12S-J1000-R B12S-J1000-S 3G SAS-3G SAS


Fibre to Fibre head The 1U-profile ESDS FF-R4031 and ESDS FF-S4031 controller heads feature 4Gb/s FC channels and support up to 224 drives. With scalability to expansion enclosures, both secure and cost-effective storage can be achieved for companies managing high volumes of data transactions on FC drives and second-tier capacity on SATA drives.

Model

FF-R4031-6

FF-S4031-6

4G FC to 4G FC Redundant RAID Heads

4G FC to 4G FC Single-UPG RAID Heads

Rear View

1U Rackmount

Form Factor

ASIC400

Controller Drive Channels*1 Hot Swap Trays

Host Channels*1 Expansion Channels*2

. 6 Channels / 4 G FC . Each channel has two (2) SFP ports (PBC) . Each channel model has built-in HUB which links the two(2) controllers and two(2) SFP ports in one(1) loop . Every channel can be assigned as host or drive channel mode, dual-loop

Redundant Controller*3

Single controller upgradeable to redundant

Redundant Controller Enabled

RAID Function

RAID 0, 1, (0+1), 3, 5, 6,10, 30, 50, 60 with local spare, global spare, and enclosure spare drives Multiple RAID logical drives (LD), logical volumes (LV), partitions, host IDs, host LUNs, instant RAID ready, LD configuration on disks, dynamic host LUN mappings.

Advanced Functions

Host-side redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric log-in (supported on fibre-host models) Dual-mode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Auto-sync firmware and configuration on replacement controller

Management

LCD front panel: Easy-to-use tool for accessing system functions and features that does not require software installation or management server. RS-232 Terminal: User friendly menu-driven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including e-mail, LAN broadcast, SNMP trap, MSN and fax).

Management via Built-in LAN

Embedded RAIDWatch: Storage management, event notifications (e-mail, SNMP trap, etc.) via HTTP. Telnet-terminal: use- friendly menu for accessing all functions and features via telnet.

Hot Swap Cooling Modules

2

Hot Swap Power Supplies

(2) x 250 W

Cache Memory*4

1GB - 2GB DDR (PC-3200 DDR400)

Cache Backup*5

BBU

Variations & Spare Parts Controller Module

86F40RE6CDMA (INC x 1 ) 86F40RE6CDMB (OPT)

86F40RE6CDMA (INC x 2 ) 86F40RE6CDMB (OPT)

9276CFanMod (INC x 2)

Fan Module Power Supply Module

9276CPSU (INC x 2)

Channel IO Module

9276CF4HIO2(INC x 6)

RS-232C Cable

9270AYCab (INC x 1)

9270ASCab (INC x 1)

UPS Cable

9270CUPSYCab (OPT)

9270CUPSCab (OPT)

RS-232C Null Modem

9011 (INC x 1)

Fibre SFP

9270CSFP4GA01(OPT)

Cable

9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT)

Cache Memory*4 BBU or CBM*5

9276CSlider36 (OPT) DDRESCEMA ( 1GB, INC x 2) DDRESCMB ( 2GB, OPT)

DDRESC EMA (1GB, INC x 1) DDRESC MB ( 2GB, OPT)

Included (INC x 2) 9276CBTE (OPT)

Included (INC x 1) 9276CBTE (OPT) QIG (INC) CD (INC x 2)

CD, Manual & Quick Installation Guide*7

* 5. There two cache backup methods. One is battery backup, providing power to cache memory during power outages. Another is cache backup module, providing power to save cache memory data into a flash module during power outages. A cache backup module(CBM)consists of a BBU and Flash module. * 6. For details about rackmount kits, please refer to page 23. * 7. All hardware and software manuals are provided in PDF format in the product CD and SANWatch CD. The Quick Installation Guide (QIG) provides basic steps to set up and configure the subsystem and activate the software licenses. For detailed functions and settings, please refer to the hardware and software manual * 8. MUX board for SAS 6Gb/s drive side and SFF models is user-supplied.

* 1. Host-side dual-loop is supported by using multi-path software on the OS or EonPath to provide path redundancy. Drive-side dual-loop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dual-loops. * 2. SAS expansion ports connect SAS JBOD when there is a need to expand subsystem capacity. * 3. Single-UPG: Single RAID controller upgradable to redundant Redundant : Dual-Redundant controller configuration * 4. We do not recommend using 3rd-party memory module due to compatibility issues. Please contact Infortrend for compatible memory modules. 2

All specifications are subject to change without prior notice.

Rack Mount Kits*6


Fibre to Fibre RAID Subsystem

Infortrend's 4Gb/s Fibre Channel (FC) host or the latest 8Gb/s FC host storage subsystems feature outstanding performance, robust availability and high capacity. They help users meet intense data center demands in a SAN environment.

Model

F16F-R4840

F16F-S4840

F16F-R4031-6/4

F16F-S4031-6/4

8G FC to 4G FC RAID Redundant Subsystems

8G FC to 4G FC RAID Single-UPG Subsystems

4G FC to 4G FC RAID Redundant Subsystems

4G FC to 4G FC RAID Single-UPG Subsystems

Rear View

Form Factor

3U 16-bay

3U 16-bay

Controller

ASIC667

ASIC400

16 Channels / 16-bay FC 4Gb/s drives

Drive Channels*1 Hot Swap Trays

Host Channels*1

. 4 Channels / 8 G FC . Each channel has two (2) SFP ports

Expansion Channels*2 Redundant Controller*3

. 2 Channels / 8 G FC . Each channel has two (2) SFP ports

. 6/4 Channels / 4G FC . Each channel has two (2) SFP ports (PBC) . Each channel model has built-in HUB which links the two (2) controllers and two(2) SFP ports in one (1) loop

Four (4) 4G FC SFP ports Single controller upgradeable to redundant

Redundant Controller Enabled

Single controller upgradeable to redundant

Redundant Controller Enabled

RAID Function

RAID 0, 1, (0+1), 3, 5, 6,10, 30, 50, 60 with local spare, global spare, and enclosure spare drives Multiple RAID logical drives (LD), logical volumes (LV), partitions, host IDs, host LUNs, instant RAID ready, LD configuration on disks, dynamic host LUN mappings.

Advanced Functions

Host-side redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric log-in (supported on fibre-host models) Dual-mode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Auto-sync firmware and configuration on replacement controller

Management

LCD front panel: Easy-to-use tool for accessing system functions and features that does not require software installation or management server. RS-232 Terminal: User friendly menu-driven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including e-mail, LAN broadcast, SNMP trap, MSN and fax).

Management via Built-in LAN

Embedded RAIDWatch: Storage management, event notifications (e-mail, SNMP trap, etc.) via HTTP. Telnet-terminal: use- friendly menu for accessing all functions and features via telnet.

Hot Swap Cooling Modules

2(Embedded in PSU)

2 (Embedded in PSU)

Hot Swap Power Supplies

(2) x 530 W

(2) x 530 W

Cache Memory*4

1GB - 4GB DDR-II

1GB - 2GB DDR (PC-3200 DDR400)

Cache Backup*5

CBM or BBU

BBU

Variations & Spare Parts Controller Module

83 FF48RF16DA (INC x 1) 83FF48RF16DB(OPT) 83FF48RF16DC(OPT)

83 FF48RF16DA (INC x 2) 83FF48RF16DB(OPT) 83FF48RF16DC(OPT)

9273ECFanMod (INC x 2)

Included x 2

Fan Module Power Supply Module

83F40REC4DMA (INC x 1 for -4 ) 83F40REC6DMA (INC x 1 for -6) 83F40REC6DMA (OPT for -6) 83F40REC4DMB (OPT for -4)

83F40REC4DMA (INC x 2 for -4 ) 83F40REC6DMA (INC x 2 for -6 ) 83F40REC6DMB (OPT for -6) 83F40REC4DMB (OPT for -4)

9373CPSU (INC x 2)

9273ECPSU (INC x 2)

Drive tray

9373CDTray (INC x 16)

9273CDTray (INC x 16)

Channel IO Module

9373F4DIO2L (INC x 1) 9373F4DIO2L (INC x 1)

RS-232C Cable

9373AYCAB (INC x 1)

9273CF4HIO2L (INC x 1) 9273CF4HIO2R(INC x 1)

9373ASCAB (OPT)

9273F4DIO2L (INC x 1 for 4) 9273F4DIO2R (INC x 1 for 4) 9273F4DIO4L (INC x 1 for 6) 9273F4DIO4R (INC x 1 for 6)

9270AYCab (INC x 1)

9270ASCab (INC x 1)

9270CUPSYCab (OPT )

UPS Cable

9270CUPSCab (OPT)

9011 (INC x 1)

Fibre SFP

9 3 70 CSFP8G ( OPT) 9270CSFP4GA01(OPT)

9270CSFP4GA01 (OPT)

Cable

9270 CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT)

9270CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT)

9373CSlider36 (INC)

9273CSlider32 (OPT) 9273CSlider36 (OPT)

Rack Mount Kits*6

Cache Memory*4

BBU or CBM*5 CD, Manual & Quick Installtion Guide*7

DDR2RECMA (1GB, INC x 2) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT)

DDR2RECMA (1GB, INC x 1) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT)

DDRESCEMA (1GB, INC x 2) DDRESCMB (2GB, OPT)

DDRESCEMA (1GB, INC x 1) DDRESCMB (2GB, OPT)

9373CCBM (INC x 2) 9373CBBU (OPT) 9373CFBM (OPT)

9373CCBM (INC x 1) 9373CBBU (OPT) 9373CFBM (OPT)

Included x 2 9273CBTE (OPT)

Included x 1 9273CBTE (OPT)

QIG (INC) CD (INC x 2)

QIG(INC) CD (INC x 2) 3

All specifications are subject to change without prior notice.

-

RS-232C Null Modem


Fibre to SAS/SATA RAID Subsystem Leveraging Infortrend's world-class RAID engine and Fibre Channel technology, EonStor DS systems can deliver breakthrough performance for data-intensive applications. With EonStor DS Fibre-host Series, SMBs can enjoy the enterprise-class data protection and high performance at reasonable and affordable prices. Model

S24F-R2840-4

S24F-G2840-4

8G FC to SAS/SATA RAID Redundant Subsystems

8G FC to SAS/SATA RAID Single Subsystems

Rear View

4U-24 Bay ASIC667

Form Factor Controller

24 Channels / 24 -bay SAS 6Gb/s / SATA - II 3 Gb / s drives

Drive Channels*1 Hot Swap Trays

4 Channels / 8G FC Four (4) 8G FC SFPs per controller

4 Channels / 8G FC Four (4) 8G FC SFPs per controller

Expansion Channels*2

Two (2) SAS 6Gb/s 4x wide port (SFF-8088)

One (1) SAS 6Gb/s 4x wide port (SFF-8088)

Redundant Controller*3

Redundant Controller Enabled

-

Host Channels*1

RAID Function

RAID 0, 1, (0+1), 3, 5, 6,10, 30, 50, 60 with local spare, global spare, and enclosure spare drives Multiple RAID logical drives (LD), logical volumes (LV), partitions, host IDs, host LUNs, instant RAID ready, LD configuration on disks, dynamic host LUN mappings.

Advanced Functions

Host-side redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric log-in (supported on fibre-host models). Dual-mode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Auto-sync firmware and configuration on replacement controller

Management

LCD front panel: Easy-to-use tool for accessing system functions and features that does not require software installation or management server. RS-232 Terminal: User friendly menu-driven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including e-mail, LAN broadcast, SNMP trap, MSN and fax).

Management via Built-in LAN

Embedded RAIDWatch: Storage management, event notifications (e-mail, SNMP trap, etc.) via HTTP. Telnet-terminal: use- friendly menu for accessing all functions and features via telnet.

Hot Swap Cooling Modules

3

Hot Swap Power Supplies

(2) x 405 W

Cache Memory*4

1GB - 4GB DDR-II

Cache Backup*5

CBM or BBU

Variations & Spare Parts Controller Module

84SF28RF244DA (INC x 2) 84SF28RF244DB (OPT) 84SF28RF244DC (OPT)

84SF28GF244DA (INC x 1) 84SF28GF244DB (OPT) 84SF28GF244DC (OPT) 9374CFanMod (INC x 3)

Fan Module Power Supply Module

9274CPSU (INC x 2)

MUX board*8

9373CDTray (INC x 24) 9373CMUX3GTRP (OPT) 9373CMUX3G (OPT)

RS-232C Cable

9373AYCAB (INC x 1)

Drive Tray

9373CDTray (INC x 24) 9373ASCAB (OPT) 9 3 70 CSFP8G ( OPT)

Fibre SFP Cable Cable for SAS JBOD expansion

Rack Mount Kits*6 Cache Memory*4 BBU or CBM*5

9373CSlider36 (INC) DDR2RECMA (1GB, INC x 2) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT) 9373CCBM (INC x 2) 9373CBBU (OPT) 9373CFBM (OPT)

DDR2RECMA (1GB, INC x 1) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT) 9373CCBM (OPT) 9373CBBU (OPT) 9373CFBM (OPT) QIG (INC) CD (INC x 2)

CD, Manual & Quick Installation Guide*7

* 5. There two cache backup methods. One is battery backup, providing power to cache memory during power outages. Another is cache backup module, providing power to save cache memory data into a flash module during power outages. A cache backup module(CBM)consists of a BBU and Flash module. * 6. For details about rackmount kits, please refer to page 23. * 7. All hardware and software manuals are provided in PDF format in the product CD and SANWatch CD. The Quick Installation Guide (QIG) provides basic steps to set up and configure the subsystem and activate the software licenses. For detailed functions and settings, please refer to the hardware and software manual * 8. MUX board for SAS 6Gb/s drive side and SFF models is user-supplied.

* 1. Host-side dual-loop is supported by using multi-path software on the OS or EonPath to provide path redundancy. Drive-side dual-loop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dual-loops. * 2. SAS expansion ports connect SAS JBOD when there is a need to expand subsystem capacity. * 3. Single-UPG: Single RAID controller upgradable to redundant Redundant : Dual-Redundant controller configuration * 4. We do not recommend using 3rd-party memory module due to compatibility issues. Please contact Infortrend for compatible memory modules. 4

All specifications are subject to change without prior notice.

9270 CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 9270 CmSASCab1 (OPT) 9270CmSASCab2 (OPT) 9270CmSASCab6 (OPT)


Fibre to SAS/SATA RAID Subsystem • Array-based snapshots and volume mirror/copy • 4Gb/s or 8Gb/s high-speed FC-host connectivity • High availability features with redundant hardware components • Pay-as-you-grow scalability with expansion units • Easy to deploy and manage with SANWatch storage management suite • Green enhancements Model

S24F-R1840-4

S24F-G1840-4

S24F-R1440

S24F-G1440

8G FC to SAS/SATA RAID Redundant Subsystems

8G FC to SAS/SATA RAID Single Subsystems

4G FC to SAS/SATA RAID Redundant Subsystems

4G FC to SAS/SATA RAID Single Subsystems

Rear View

4U-24 Bay

Form Factor

ASIC667

Controller Drive Channels*1 Hot Swap Trays

Host Channels*1

4 Channels / 8G FC Four (4) 8G FC SFPs per controller

24 Channels / 24 -bay SAS/SATA - II 3 Gb / s drives 4 Channels / 8G FC 2 Channels / 4G FC Four (4) 8G FC SFPs per controller Two (2) 4G FC SFPs per controller

2 Channels / 4G FC Two (2) 4G FC SFPs per controller

Expansion Channels*2

Two (2) SAS 4x wide port (SFF-8088)

One (1) SAS 4x wide port (SFF-8088)

Two (2) SAS 4x wide port (SFF-8088)

One (1) SAS 4x wide port (SFF-8088)

Redundant Controller*3

Redundant Controller Enabled

-

Redundant Controller Enabled

-

RAID Function

RAID 0, 1, (0+1), 3, 5, 6,10, 30, 50, 60 with local spare, global spare, and enclosure spare drives Multiple RAID logical drives (LD), logical volumes (LV), partitions, host IDs, host LUNs, instant RAID ready, LD configuration on disks, dynamic host LUN mappings.

Advanced Functions

Host-side redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric log-in (supported on fibre-host models) Dual-mode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Auto-sync firmware and configuration on replacement controller

Management

LCD front panel: Easy-to-use tool for accessing system functions and features that does not require software installation or management server. RS-232 Terminal: User friendly menu-driven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including e-mail, LAN broadcast, SNMP trap, MSN and fax).

Management via Built-in LAN

Embedded RAIDWatch: Storage management, event notifications (e-mail, SNMP trap, etc.) via HTTP. Telnet-terminal: use- friendly menu for accessing all functions and features via telnet.

Hot Swap Cooling Modules

3

Hot Swap Power Supplies

(2) x 405 W

Cache Memory*4

1GB - 4GB DDR-II

Cache Backup*5

CBM or BBU

Variations & Spare Parts Controller Module

84SF18RF244DA (INC x 2) 84SF18RF244DB (OPT) 84SF18RF244DC (OPT)

84SF18GF244DA (INC x 1) 84SF18GF244DB (OPT) 84SF18GF244DC (OPT)

84SF14RF24DMA (INC x 2) 84SF14RF24DMB (OPT) 84SF14RF24DMC (OPT)

84SF14GF24DMA (INC x 1) 84SF14GF24DMB (OPT) 84SF14GF24DMC (OPT)

9374CFanMod (INC x 3)

Fan Module Power Supply Module

9274CPSU (INC x 2) 9373S1DT2S1S (INC x 24)

9373CDTray (INC x 24)

9373S1DT2S1S (INC x 24)

9373CDTray (INC x 24)

MUX board*8

9273S1N2S1S (OPT)

9273S1N2S1S (OPT)

RS-232C Cable

9373AYCAB (INC x 1)

9373ASCAB (OPT)

9373ASCAB (OPT)

Drive tray

Fibre SFP

9 3 70 CSFP8G ( OPT)

9270 CSFP4GA01 ( OPT)

Cable for SAS JBOD expansion Rack Mount Kits*6

BBU or CBM*5

DDR2RECMA (1GB, INC x 2) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT) 9373CCBM (INC x 2) 9373CBBU (OPT) 9373CFBM (OPT)

DDR2RECMA (1GB, INC x 1) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT) 9373CCBM (OPT) 9373CBBU (OPT) 9373CFBM (OPT)

DDR2RECMA (1GB, INC x 2) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT) 9373CCBM (INC x 2) 9373CBBU (OPT) 9373CFBM (OPT)

DDR2RECMA (1GB, INC x 1) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT) 9373CCBM (OPT) 9373CBBU (OPT) 9373CFBM (OPT)

QIG (INC) CD (INC x 2)

CD, Manual & Quick Installation Guide*7

* 5. There two cache backup methods. One is battery backup, providing power to cache memory during power outages. Another is cache backup module, providing power to save cache memory data into a flash module during power outages. A cache backup module(CBM)consists of a BBU and Flash module. * 6. For details about rackmount kits, please refer to page 23. * 7. All hardware and software manuals are provided in PDF format in the product CD and SANWatch CD. The Quick Installation Guide (QIG) provides basic steps to set up and configure the subsystem and activate the software licenses. For detailed functions and settings, please refer to the hardware and software manual * 8. MUX board for SAS 6Gb/s drive side and SFF models is user-supplied.

* 1. Host-side dual-loop is supported by using multi-path software on the OS or EonPath to provide path redundancy. Drive-side dual-loop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dual-loops. * 2. SAS expansion ports connect SAS JBOD when there is a need to expand subsystem capacity. * 3. Single-UPG: Single RAID controller upgradable to redundant Redundant : Dual-Redundant controller configuration * 4. We do not recommend using 3rd-party memory module due to compatibility issues. Please contact Infortrend for compatible memory modules. 5

All specifications are subject to change without prior notice.

9270 CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT) 9270 CmSASCab3 (OPT) 9270CmSASCab4 (OPT) 9270CmSASCab5 (OPT) 9373CSlider36 (INC)

Cable

Cache Memory*4

9373AYCAB (INC x1)


Fibre to SAS/SATA RAID Subsystem Leveraging Infortrend's world-class RAID engine and Fibre Channel technology, EonStor DS systems can deliver breakthrough performance for data-intensive applications. With EonStor DS Fibre-host Series, SMBs can enjoy the enterprise-class data protection and high performance at reasonable and affordable prices. Model

S16F-R2840-4

S16F-G2840-4

S16F-R1840-4

S16F-G1840-4

8G FC to SAS/SATA RAID Redundant Subsystems

8G FC to SAS/SATA RAID Single Subsystems

8G FC to SAS/SATA RAID Redundant Subsystems

8G FC to SAS/SATA RAID Single Subsystems

Rear View

3U-16 Bay

Form Factor

ASIC667

Controller Drive Channels*1 Hot Swap Trays

Host Channels*1

16 Channels / 16 -bay SAS / SATA - II 3 Gb / s drives 4 Channels / 8G FC 4 Channels / 8G FC Four (4) 8G FC SFPs per controller Four (4) 8G FC SFPs per controller

16 Channels / 16 -bay SAS 6Gb/s / SATA-II 3Gb/s drives 4 Channels / 8G FC 4 Channels / 8G FC Four (4) 8G FC SFPs per controller Four (4) 8G FC SFPs per controller

Expansion Channels*2

Two (2) SAS 6Gb/s 4x wide port (SFF-8088)

One (1) SAS 6Gb/s 4x wide port (SFF-8088)

Two (2) SAS 4x wide port (SFF-8088)

One (1) SAS 4x wide port (SFF-8088)

Redundant Controller*3

Redundant Controller Enabled

-

Redundant Controller Enabled

-

RAID Function

RAID 0, 1, (0+1), 3, 5, 6,10, 30, 50, 60 with local spare, global spare, and enclosure spare drives Multiple RAID logical drives (LD), logical volumes (LV), partitions, host IDs, host LUNs, instant RAID ready, LD configuration on disks, dynamic host LUN mappings.

Advanced Functions

Host-side redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric log-in (supported on fibre-host models). Dual-mode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Auto-sync firmware and configuration on replacement controller

Management

LCD front panel: Easy-to-use tool for accessing system functions and features that does not require software installation or management server. RS-232 Terminal: User friendly menu-driven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including e-mail, LAN broadcast, SNMP trap, MSN and fax).

Management via Built-in LAN

Embedded RAIDWatch: Storage management, event notifications (e-mail, SNMP trap, etc.) via HTTP. Telnet-terminal: use- friendly menu for accessing all functions and features via telnet.

Hot Swap Cooling Modules

2 (Enbedded in PSU)

Hot Swap Power Supplies

(2) x 530 W

Cache Memory*4

1GB - 4GB DDR-II

Cache Backup*5

CBM or BBU

Variations & Spare Parts Controller Module

83SF28RF164DA (INC x 2) 83SF28RF164DB (OPT) 83SF28RF164DC (OPT)

83SF28GF164DA (INC x 2) 83SF28GF164DB (OPT) 83SF28GF164DC (OPT)

9373CPSU (INC x 2) 9373CDTray (INC x 16) 9373CMUX3GTRP (OPT)

9373CDTray (INC x 16)

9373S1DT2S1S (INC x 16)

9373CDTray (INC x 16) 9373ASCAB (OPT)

MUX board*8

9373CMUX3G (OPT)

-

9273S1N2S1S (OPT)

RS-232C Cable

9373AYCAB (INC x 1)

9373ASCAB (OPT)

9373AYCAB (INC x 1) 9 3 70 CSFP8G ( OPT)

Fibre SFP

9270 CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT)

Cable Cable for SAS JBOD expansion

9270 CmSASCab1 (OPT) 9270CmSASCab2 (OPT) 9270CmSASCab6 (OPT)

9270 CmSASCab3 (OPT) 9270CmSASCab4 (OPT) 9270CmSASCab5 (OPT)

BBU or CBM*5

DDR2RECMA (1GB, INC x 2) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT) 9373CCBM (INC x 2) 9373CBBU (OPT) 9373CFBM (OPT)

DDR2RECMA (1GB, INC x 2) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT) 9373CCBM (INC x 2) 9373CBBU (OPT) 9373CFBM (OPT)

DDR2RECMA (1GB, INC x 1) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT) 9373CCBM (OPT) 9373CBBU (OPT) 9373CFBM (OPT)

DDR2RECMA (1GB, INC x 1) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT) 9373CCBM (OPT) 9373CBBU (OPT) 9373CFBM (OPT)

QIG (INC) CD (INC x 2)

CD, Manual & Quick Installation Guide*7

* 5. There two cache backup methods. One is battery backup, providing power to cache memory during power outages. Another is cache backup module, providing power to save cache memory data into a flash module during power outages. A cache backup module(CBM)consists of a BBU and Flash module. * 6. For details about rackmount kits, please refer to page 23. * 7. All hardware and software manuals are provided in PDF format in the product CD and SANWatch CD. The Quick Installation Guide (QIG) provides basic steps to set up and configure the subsystem and activate the software licenses. For detailed functions and settings, please refer to the hardware and software manual * 8. MUX board for SAS 6Gb/s drive side and SFF models is user-supplied.

* 1. Host-side dual-loop is supported by using multi-path software on the OS or EonPath to provide path redundancy. Drive-side dual-loop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dual-loops. * 2. SAS expansion ports connect SAS JBOD when there is a need to expand subsystem capacity. * 3. Single-UPG: Single RAID controller upgradable to redundant Redundant : Dual-Redundant controller configuration * 4. We do not recommend using 3rd-party memory module due to compatibility issues. Please contact Infortrend for compatible memory modules. 6

All specifications are subject to change without prior notice.

9373CSlider36 (INC)

Rack Mount Kits*6 Cache Memory*4

83SF18GF164DA (INC x 1) 83SF18GF164DB (OPT) 83SF18GF164DC (OPT)

Included

Fan Module Power Supply Module

Drive tray

83SF18RF164DA (INC x 2) 83SF18RF164DB (OPT) 83SF18RF164DC (OPT)


Fibre to SAS/SATA RAID Subsystem • Array-based snapshots and volume mirror/copy • 4Gb/s or 8Gb/s high-speed FC-host connectivity • High availability features with redundant hardware components • Pay-as-you-grow scalability with expansion units • Easy to deploy and manage with SANWatch storage management suite • Green enhancements

S16F-R1440

S16F-G1440

S12F-R2840-4

S12F-G2840-4

4G FC to SAS/SATA RAID Redundant Subsystems

4G FC to SAS/SATA RAID Single Subsystems

8G FC to SAS/SATA RAID Redundant Subsystems

8G FC to SAS/SATA RAID Single Subsystems

Model

Rear View

3U-16 Bay

Form Factor

2U-12 Bay ASIC667

Controller

16 Channels / 16-bay SAS/SATA - II 3 Gb / s drives

Drive Channels*1 Hot Swap Trays

Host Channels*1

4 Channels / 4G FC Four (4) 4G FC SFPs per controller

Expansion Channels*2

Two (2) SAS 4x wide port (SFF-8088)

Redundant Controller*3

Redundant Controller Enabled

2 Channels / 4G FC Two (2) 4G FC SFPs per controller

12 Channels / 1 2 -bay SAS 6Gb/s / SATA-II 3Gb/s drives 4 Channels / 8G FC 4 Channels / 8G FC Four (4) 8G FC SFPs per controller Four (4) 8G FC SFPs per controller

One (1) SAS 4x wide port (SFF-8088) -

Two (2) SAS 6Gb/s 4x wide port (SFF-8088)

One (1) SAS 6Gb/s 4x wide port (SFF-8088)

Redundant Controller Enabled

-

RAID Function

RAID 0, 1, (0+1), 3, 5, 6,10, 30, 50, 60 with local spare, global spare, and enclosure spare drives Multiple RAID logical drives (LD), logical volumes (LV), partitions, host IDs, host LUNs, instant RAID ready, LD configuration on disks, dynamic host LUN mappings.

Advanced Functions

Host-side redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric log-in (supported on fibre-host models). Dual-mode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Auto-sync firmware and configuration on replacement controller

Management

LCD front panel: Easy-to-use tool for accessing system functions and features that does not require software installation or management server. RS-232 Terminal: User friendly menu-driven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including e-mail, LAN broadcast, SNMP trap, MSN and fax).

Management via Built-in LAN

Embedded RAIDWatch: Storage management, event notifications (e-mail, SNMP trap, etc.) via HTTP. Telnet-terminal: use- friendly menu for accessing all functions and features via telnet.

Hot Swap Cooling Modules

2 (Embedded in PSU)

2 (Embedded in PSU)

2

(2) x 530 W

(2) x 530 W

(2) x 350 W

85SF28RF124DA (INC x 2) 85SF28RF124DB (OPT) 85SF28RF124DC (OPT)

82SF28GF124DA (INC x 1) 82SF28GF124DB (OPT) 82SF28GF124DC (OPT)

Included

9272CPSU (INC x 2)

9373CPSU (INC x 2)

9372CFanMod (INC x 2)

9373CDTray (INC x 12) 9373CMUX3GTRP (OPT)

9373CDTray (INC x 12)

Hot Swap Power Supplies Cache Memory*4

1GB - 4GB DDR-II

Cache Backup*5

CBM or BBU

Variations & Spare Parts Controller Module

83SF14GF16DMA (INC x 1) 83SF14GF16DMB (OPT) 83SF14GF16DMC (OPT)

83SF14RF16DMA (INC x 2) 83SF14RF16DMB (OPT) 83SF14RF16DMC (OPT) Included

Fan Module Power Supply Module

9373CPSU (INC x 2) 9373S1DT2S1S (INC x 16)

9373CDTray (INC x 16)

MUX board*8

9273S1N2S1S (OPT)

RS-232C Cable

9373AYCAB (INC x 1)

9373ASCAB (OPT)

Drive tray

Fibre SFP

9270 CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT)

BBU or CBM*5

DDR2RECMA (1GB, INC x 2) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT) 9373CCBM (INC x 2) 9373CBBU (OPT) 9373CFBM (OPT)

9270 CmSASCab1 (OPT) 9270CmSASCab2 (OPT) 9270CmSASCab6 (OPT)

9373CSlider36 (INC) DDR2RECMA (1GB, INC x 1) DDR2RECMA (1GB, INC x 2) DDR2RECMB (2GB, OPT) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT) DDR2RECMC (4GB, OPT) 9373CCBM (OPT) 9373CBBU (OPT) 9373CFBM (OPT)

9373CCBM (INC x 2) 9373CBBU (OPT) 9373CFBM (OPT)

DDR2RECMA (1GB, INC x 1) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT) 9373CCBM(OPT) 9373CBBU (OPT) 9373CFBM (OPT)

QIG (INC) CD (INC x 2)

CD, Manual & Quick Installation Guide*7

* 5. There two cache backup methods. One is battery backup, providing power to cache memory during power outages. Another is cache backup module, providing power to save cache memory data into a flash module during power outages. A cache backup module(CBM)consists of a BBU and Flash module. * 6. For details about rackmount kits, please refer to page 23. * 7. All hardware and software manuals are provided in PDF format in the product CD and SANWatch CD. The Quick Installation Guide (QIG) provides basic steps to set up and configure the subsystem and activate the software licenses. For detailed functions and settings, please refer to the hardware and software manual * 8. MUX board for SAS 6Gb/s drive side and SFF models is user-supplied.

* 1. Host-side dual-loop is supported by using multi-path software on the OS or EonPath to provide path redundancy. Drive-side dual-loop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dual-loops. * 2. SAS expansion ports connect SAS JBOD when there is a need to expand subsystem capacity. * 3. Single-UPG: Single RAID controller upgradable to redundant Redundant : Dual-Redundant controller configuration * 4. We do not recommend using 3rd-party memory module due to compatibility issues. Please contact Infortrend for compatible memory modules. 7

All specifications are subject to change without prior notice.

9270 CmSASCab3 (OPT) 9270CmSASCab4 (OPT) 9270CmSASCab5 (OPT)

Rack Mount Kits*6 Cache Memory*4

9373ASCAB (OPT)

9370 CSFP8G ( OPT)

9270 CSFP4GA01 ( OPT)

Cable Cable for SAS JBOD expansion

9373CMUX3G (OPT) 9373AYCAB (INC x 1)


Fibre to SAS/SATA RAID Subsystem Leveraging Infortrend's world-class RAID engine and Fibre Channel technology, EonStor DS systems can deliver breakthrough performance for data-intensive applications. With EonStor DS Fibre-host Series, SMBs can enjoy the enterprise-class data protection and high performance at reasonable and affordable prices. Model

S12F-R1840-4

S12F-G1842-4

S12F-R1440

S12F-G1440

8G FC to SAS/SATA RAID Redundant Subsystems

8G FC to SAS/SATA RAID Single Subsystems

4G FC to SAS/SATA RAID Redundant Subsystems

4G FC to SAS/SATA RAID Single Subsystems

Rear View

2U-12 Bay

Form Factor

ASIC667 12 Channels / 1 2 -bay SAS/SATA - II 3 Gb / s drives

Controller Drive Channels*1 Hot Swap Trays

8 Channels / 8G FC Four (4) 8G FC SFPs per controller

4 Channels / 8G FC Four (4) 8G FC SFPs per controller

4 Channels / 4G FC Two (2) 4G FC SFPs per controller

2 Channels / 4G FC Two (2) 4G FC SFPs per controller

Expansion Channels*2

Two (2) SAS 4x wide port (SFF-8088)

One (1) SAS 4x wide port (SFF-8088)

Two (2) SAS 4x wide port (SFF-8088)

One (1) SAS 4x wide port (SFF-8088)

Redundant Controller*3

Redundant Controller Enabled

-

Redundant Controller Enabled

-

Host Channels*1

RAID Function

RAID 0, 1, (0+1), 3, 5, 6,10, 30, 50, 60 with local spare, global spare, and enclosure spare drives Multiple RAID logical drives (LD), logical volumes (LV), partitions, host IDs, host LUNs, instant RAID ready, LD configuration on disks, dynamic host LUN mappings.

Advanced Functions

Host-side redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric log-in (supported on fibre-host models). Dual-mode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Auto-sync firmware and configuration on replacement controller

Management

LCD front panel: Easy-to-use tool for accessing system functions and features that does not require software installation or management server. RS-232 Terminal: User friendly menu-driven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including e-mail, LAN broadcast, SNMP trap, MSN and fax).

Management via Built-in LAN

Embedded RAIDWatch: Storage management, event notifications (e-mail, SNMP trap, etc.) via HTTP. Telnet-terminal: use- friendly menu for accessing all functions and features via telnet.

Hot Swap Cooling Modules Hot Swap Power Supplies

2 (Embedded in PSU)

2

2 (Embedded in PSU)

3

(2) x 530 W

(2) x 350 W

(2) x 530 W

(2) x 350 W

85SF14RF12DMA (INC x 2) 85SF14RF12DMB (OPT) 85SF14RF12DMC (OPT)

Included

82SF18GF124DA (INC x 1) 82SF18GF124DB (OPT) 82SF18GF124DC (OPT) 9372CFanMod (INC x 2)

Included

82SF14GF12DMA (INC x 2) 82SF14GF12DMB (OPT) 82SF14GF12DMC (OPT) 9279CFanMod (INC x 3)

9373CPSU (INC x 2)

9272CPSU (INC x 2)

9373CPSU (INC x 2)

9272CPSU (INC x 2) 9373CDTray (INC x 12)

Cache Memory*4

1GB - 4GB DDR-II

Cache Backup*5

CBM or BBU

Variations & Spare Parts Controller Module Fan Module Power Supply Module

85SF18RF124DA (INC x 2) 85SF18RF124DB (OPT) 85SF18RF124DC (OPT)

9373S1DT2S1S (INC x 12)

9373CDTray (INC x 12)

9373S1DT2S1S (INC x 12)

MUX board*8

9273S1N2S1S (OPT)

-

9273S1N2S1S (OPT)

RS-232C Cable

9373AYCAB (INC x 1)

9373ASCAB (OPT)

9373AYCAB (INC x 1)

Drive tray

Fibre SFP

9 3 70 CSFP8G ( OPT)

9270 CSFP4GA01 ( OPT) 9270 CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT)

Cable Cable for SAS JBOD expansion

9270 CmSASCab1 (OPT) 9270CmSASCab2 (OPT) 9270CmSASCab6 (OPT)

9270 CmSASCab3 (OPT) 9270CmSASCab4 (OPT) 9270CmSASCab5 (OPT)

DDR2RECMA (1GB, INC x 2) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT) 9373CCBM (INC x 2) 9373CBBU (OPT) 9373CFBM (OPT)

DDR2RECMA (1GB, INC x 1) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT)

DDR2RECMA (1GB, INC x 2) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT) 9373CCBM (INC x 2) 9373CBBU (OPT) 9373CFBM (OPT)

DDR2RECMA (1GB, INC x 1) DDR2RECMB (2GB, OPT) DDR2RECMC (4GB, OPT)

9373CCBM (OPT) 9373CBBU (OPT) 9373CFBM (OPT)

9373CCBM (OPT) 9373CBBU (OPT) 9373CFBM (OPT)

QIG (INC) CD (INC x 2)

CD, Manual & Quick Installation Guide*7

* 5. There two cache backup methods. One is battery backup, providing power to cache memory during power outages. Another is cache backup module, providing power to save cache memory data into a flash module during power outages. A cache backup module(CBM)consists of a BBU and Flash module. * 6. For details about rackmount kits, please refer to page 23. * 7. All hardware and software manuals are provided in PDF format in the product CD and SANWatch CD. The Quick Installation Guide (QIG) provides basic steps to set up and configure the subsystem and activate the software licenses. For detailed functions and settings, please refer to the hardware and software manual * 8. MUX board for SAS 6Gb/s drive side and SFF models is user-supplied.

* 1. Host-side dual-loop is supported by using multi-path software on the OS or EonPath to provide path redundancy. Drive-side dual-loop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dual-loops. * 2. SAS expansion ports connect SAS JBOD when there is a need to expand subsystem capacity. * 3. Single-UPG: Single RAID controller upgradable to redundant Redundant : Dual-Redundant controller configuration * 4. We do not recommend using 3rd-party memory module due to compatibility issues. Please contact Infortrend for compatible memory modules. 8

All specifications are subject to change without prior notice.

BBU or CBM*5

9270 CmSASCab1 (OPT) 9270CmSASCab2 (OPT) 9270CmSASCab6 (OPT) 9373CSlider36 (INC)

Rack Mount Kits*6 Cache Memory*4

9373ASCAB (OPT)


2.5" SAS/SATA RAID Subsystem ESDS B12F-R1430 and ESDS B12F-G1431 provide budget-friendly choices to help SMB users easily deploy high-availability 4Gb/s Fibre Channel (FC) SANs. Accommodating 12 Small Form Factor (SFF) drives in a high-density 1U enclosure, the ESDS B12F delivers optimal performance density. In mission-critical environments, their outstanding price-performance combined with enterprise-class data protection can contribute to significant business benefits

B12F-R1430

B12F-G1431

B12S-R1030

B12S-G1031

4G FC to 2.5" SAS/SATA RAID Redundant Subsystems

4G FC to 2.5" SAS/SATA RAID Single Subsystems

SAS to 2.5" SAS/SATA RAID Redundant Subsystems

SAS to 2.5" SAS/SATA RAID Single Subsystems

Model

Rear View

1U-12 Bay

Form Factor

ASIC400 12 Channels / 1 2 -bay 2.5�SAS/ S ATA drives

Controller Drive Channels*1 Hot Swap Trays

Host Channels*1 Expansion Channels*2 Redundant Controller

2 Channels / 4G FC Two (2) 4G FC SFPs per controller

2 Channels / 4G FC Two (2) 4G FC SFPs per controller

2 Channels / SAS 3Gb/s Two (2) SAS 4x wide ports (SFF-8088) per controller

Two (2) SAS 4x wide port (SFF-8088)

One (1) SAS 4x wide port (SFF-8088)

Two (2) SAS 4x wide ports (SFF-8088)

One (1) SAS 4x wide ports (SFF-8088)

Redundant Controller Enabled

-

Redundant Controller Enabled

-

RAID Function

RAID 0, 1, (0+1), 3, 5, 6,10, 30, 50, 60 with local spare, global spare, and enclosure spare drives Multiple RAID logical drives (LD), logical volumes (LV), partitions, host IDs, host LUNs, instant RAID ready, LD configuration on disks, dynamic host LUN mappings.

Advanced Functions

Host-side redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric log-in (supported on fibre-host models). Dual-mode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Auto-sync firmware and configuration on replacement controller

Management

LCD front panel: Easy-to-use tool for accessing system functions and features that does not require software installation or management server. RS-232 Terminal: User friendly menu-driven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including e-mail, LAN broadcast, SNMP trap, MSN and fax).

Management via Built-in LAN

Embedded RAIDWatch: Storage management, event notifications (e-mail, SNMP trap, etc.) via HTTP. Telnet-terminal: use- friendly menu for accessing all functions and features via telnet.

Hot Swap Cooling Modules

2

Hot Swap Power Supplies

(2) x 380 W

(2) x 250 W

(2) x 380 W

(2) x 250 W

8ABS10RE12DMA (INC x 2) 8ABS10RE12DMB (OPT)

8ABS10GE12CDA (INC x 1) 8ABS10GE12CDB (OPT)

1 GB - 2 G B DDR (PC-3200 DDR 400)

Cache Memory*3

BBU

Cache Backup*4

Variations & Spare Parts Controller Module

8ABF14RE12DMA (INC x 2) 8ABF14RE12DMB (OPT)

8ABF14GE12CDA (INC x 1) 8ABF14GE12CDB (OPT)

9ACFanMod (INC x 2)

Fan Module Power Supply Module

Drive tray

9ACPSU (INC x 2) 9ACETray (INC x 12) 9AS1DT2S1S (OPT)

9271CPSU (INC x 2)

9ACPSU (INC x 2)

9271CPSU (INC x 2)

9ACETray (INC x 12)

9ACETray (INC x 12) 9AS1DT2S1S (OPT)

9ACETray (INC x 12)

MUX board*8

9AS1N2S1S (OPT)

-

9AS1N2S1S (OPT)

-

RS-232C Cable

9270AYCab (INC x 1)

9270ASCab (INC x 1)

9270AYCab (INC x 1)

9270ASCab (INC x 1)

UPS Cable

9270CUPSYCab (OPT)

9270CUPSCab (OPT)

9270CUPSYCab (OPT)

9270CUPSCab (OPT)

RS-232C Null Modem

9011 (INC x 1) -

9270 CSFP4GA01 ( OPT)

Fibre SFP

9270 CFCCab01 (OPT) 9270CFCCab02 (OPT) 9270CFCCab03 (OPT)

Cable

9270 CmSASCab2 ( INC x 2 ) 9270CmSASCab4 (OPT)

9277CSlider36 (OPT)

Rack Mount Kits*6 Cache Memory*4 BBU or CBM*5

9270 CmSASCab3 (OPT) 9270CmSASCab4 (OPT) 9270CmSASCab5 (OPT)

DDRESCEMA (1GB, INC x 2) DDRESCMB (OPT)

DDRESCEMA (1GB, INC x 1) DDRESCMB (OPT)

Included x 2 9ACBTE (OPT)

9ACBTE (OPT)

DDRESCEMA (1GB, INC x 2) DDRESCMB (OPT) Included x 2 9ACBTE (OPT)

DDRESCEMA (1GB, INC x 1) DDRESCMB (OPT) 9ACBTE (OPT)

QIG (INC) CD (INC x 2)

CD, Manual & Quick Installation Guide*7

* 5. There two cache backup methods. One is battery backup, providing power to cache memory during power outages. Another is cache backup module, providing power to save cache memory data into a flash module during power outages. A cache backup module(CBM)consists of a BBU and Flash module. * 6. For details about rackmount kits, please refer to page 23. * 7. All hardware and software manuals are provided in PDF format in the product CD and SANWatch CD. The Quick Installation Guide (QIG) provides basic steps to set up and configure the subsystem and activate the software licenses. For detailed functions and settings, please refer to the hardware and software manual * 8. MUX board for SAS 6Gb/s drive side and SFF models is user-supplied.

* 1. Host-side dual-loop is supported by using multi-path software on the OS or EonPath to provide path redundancy. Drive-side dual-loop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dual-loops. * 2. SAS expansion ports connect SAS JBOD when there is a need to expand subsystem capacity. * 3. Single-UPG: Single RAID controller upgradable to redundant Redundant : Dual-Redundant controller configuration * 4. We do not recommend using 3rd-party memory module due to compatibility issues. Please contact Infortrend for compatible memory modules. 9

All specifications are subject to change without prior notice.

9270 CmSASCab1 (OPT) 9270CmSASCab2 (OPT) 9270CmSASCab6 (OPT)

Cable for SAS JBOD expansion

9270 CmSASCab2 ( INC x 1 ) 9270CmSASCab4 (OPT)


EonStor DS Expansion Enclosure The high density 3Gbps SAS-based expansion enclosures house twelve SAS drives in a 1U enclosure. They allow users to easily attach terabytes of capacity to the ESDS B12S and B12F storage systems. The J1000-R provides fault-tolerant links across separate SAS domains, while the J1000-S provides a single, straight-through data path

Model

B12S-J1000-R

B12S-J1000-S

SAS JBOD Subsystems

SAS JBOD Subsystems

Rear View

1U-12 Bay -

Form Factor Controller Drive Channels*1 Hot Swap Trays

12 Channels / 1 2 -bay 2.5�SAS/ S ATA drives

Host Channels*1

2 Channels / SAS 3Gb/s Two (2) SAS 4x wide ports (SFF-8088) per controller

Expansion Channels*2 Redundant Controller*3

-

RAID Function

RAID 0, 1, (0+1), 3, 5, 6,10, 30, 50, 60 with local spare, global spare, and enclosure spare drives Multiple RAID logical drives (LD), logical volumes (LV), partitions, host IDs, host LUNs, instant RAID ready, LD configuration on disks, dynamic host LUN mappings.

Advanced Functions

Host-side redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric log-in (supported on fibre-host models). Dual-mode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Auto-sync firmware and configuration on replacement controller

Management

LCD front panel: Easy-to-use tool for accessing system functions and features that does not require software installation or management server. RS-232 Terminal: User friendly menu-driven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including e-mail, LAN broadcast, SNMP trap, MSN and fax).

Management via Built-in LAN

Embedded RAIDWatch: Storage management, event notifications (e-mail, SNMP trap, etc.) via HTTP. Telnet-terminal: use- friendly menu for accessing all functions and features via telnet.

Hot Swap Cooling Modules

2

Hot Swap Power Supplies

(2) x 380 W

Cache Memory*4

-

Battery Backup*5

-

Variations & Spare Parts Controller Module

8ABS10J122D (INC x 1)

8ABS10J122D (INC x 2) 9ACFanMod (INC x 2)

Fan Module Power Supply Module

Drive tray MUX board*8 Cable

9ACPSU (INC x 2) 9ACETray (INC x 12) 9AS1DT2S1S (OPT)

9ACETray (INC x 12)

9AS1N2S1S (OPT)

-

9270 CmSASCab1 ( INC x 2 ) 9270CmSASCab3 (OPT)

9270 CmSASCab1 ( INC x 1 ) 9270CmSASCab3 (OPT)

Rack Mount Kits*6

9277CSlider36 (OPT)

CD, Manual & Quick Installtion Guide*7

QIG (INC) CD (INC x 1)

10

All specifications are subject to change without prior notice.

* 5. There two cache backup methods. One is battery backup, providing power to cache memory during power outages. Another is cache backup module, providing power to save cache memory data into a flash module during power outages. A cache backup module(CBM)consists of a BBU and Flash module. * 6. For details about rackmount kits, please refer to page 23. * 7. All hardware and software manuals are provided in PDF format in the product CD and SANWatch CD. The Quick Installation Guide (QIG) provides basic steps to set up and configure the subsystem and activate the software licenses. For detailed functions and settings, please refer to the hardware and software manual * 8. MUX board for SAS 6Gb/s drive side and SFF models is user-supplied.

* 1. Host-side dual-loop is supported by using multi-path software on the OS or EonPath to provide path redundancy. Drive-side dual-loop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dual-loops. * 2. SAS expansion ports connect SAS JBOD when there is a need to expand subsystem capacity. * 3. Single-UPG: Single RAID controller upgradable to redundant Redundant : Dual-Redundant controller configuration * 4. We do not recommend using 3rd-party memory module due to compatibility issues. Please contact Infortrend for compatible memory modules.


EonStor SAS to SAS/SATA RAID The Infortrend EonStor DS SAS-host Series is designed to help SMB users implement high-reliability DAS storage solutions with outstanding throughput. With the SAS 3G or the latest 6G technology, users can enjoy high performance and cost effectiveness and meet the needs of high-availability applications. Additionally, data service functionalities such as snapshot and volume copy/mirror are available on all products in the EonStor DS Family. Therefore, SMBs can enjoy the same high level of data protection as enterprises

S16S-R1030

S16S-G1030

S12S-R1032

S12S-G1033

SAS to SAS RAID Redundant Subsystems

SAS to SAS RAID Single Subsystems

SAS to SAS RAID Redundant Subsystems

SAS to SAS RAID Single Subsystems

Model

Rear View

3U-16 Bay

Form Factor

2U-12 Bay ASIC400

Controller Drive Channels*1 Hot Swap Trays

Host Channels*1 Expansion Channels*2 Redundant Controller*3

16 Channels / 16-bay SAS/SATA-II 3 Gb/s drives 2 Channels / SAS 3Gb/s 2 Channels / SAS 3Gb/s Two (2) SAS 4x wide port (SFF-8470) Two (2) SAS 4x wide port (SFF-8470) per controller per controller

12 Channels / 1 2 -bay SAS/SATA-II 3 Gb/s drives 2 Channels / SAS 3Gb/s 2 Channels / SAS 3Gb/s Two (2) SAS 4x wide port (SFF-8088) Two (2) SAS 4x wide port (SFF-8088) per controller per controller

Two (2) SAS 4x wide port (SFF-8470)

One (1) SAS 4x wide port (SFF-8470)

Two (2) SAS 4x wide port (SFF-8088)

Redundant Controller Enabled

-

Redundant Controller Enabled

One (1) SAS 4x wide port (SFF-8088) -

RAID Function

RAID 0, 1, (0+1), 3, 5, 6,10, 30, 50, 60 with local spare, global spare, and enclosure spare drives Multiple RAID logical drives (LD), logical volumes (LV), partitions, host IDs, host LUNs, instant RAID ready, LD configuration on disks, dynamic host LUN mappings.

Advanced Functions

Host-side redundant path and load balancing supported (EonPath software required in the host computers) , switched fabric support, fabric log-in (supported on fibre-host model). Dual-mode RAID expansion "Add-in Drive" and "Copy & Replace with large drive" Redundant models: Auto-sync firmware and configuration on replacement controller

Management

LCD front panel: Easy-to-use menu for accessing all functions and features. RS-232 Terminal: User friendly menu-driven for accessing all functions and features. SANWatch: Storage management suite. (Storage management, central view, and Notification manager via e-mail, LAN broadcast, SNMP trap, MSN and fax)

Management via Built-in LAN

Embedded RAIDWatch: Storage management, event notifications (e-mail, SNMP trap, etc.) via HTTP. Telnet-terminal: User friendly menu-driven for accessing all function and feature via telnet.

Hot Swap Cooling Modules

2 (Embedded in PSU)

Hot Swap Power Supplies

(2) x 530 W

2 (Embedded in PSU)

3

(2) x 530 W

(2) x 350 W

Cache Memory*4

1GB - 2GB DDR (PC-3200 DDR400)

Cache Backup*5

BBU

Variations & Spare Parts Controller Module

83S10RE16DMA (INC x 2) 83S10RE16DMB (OPT)

Fan Module Power Supply Module Drive tray

83S10GE16DMA (INC x 1) 83S10GE16DMB (OPT)

89S10RE12DMA (INC x 2) 89S10RE12DMB (OPT)

82S10GE12DMA (INC x 1) 82S10GE12DMB (OPT)

9273ECFanMod (INC x 2)

9279CFanMod (INC x 2)

9272CFanMod (INC x 3)

9273ECPSU (INC x 2)

9279CPSU (INC x 2)

9272CPSU (INC x 2)

9373S1DT2S1S (INC x 12)

9373CDTray (INC x 12)

9373S1DT2S1S (INC x 16)

9373CDTray (INC x 16) -

MUX board*8 RS-232C Cable

9270AYCab (INC x 1)

9270ASCab (INC x 1)

9270AYCab (INC x 1)

9270ASCab (INC x 1)

UPS Cable

9270CUPSYCab (OPT)

9270CUPSCab (OPT)

9270CUPSYCab (OPT)

9270CUPSCab (OPT)

RS-232C Null Modem Cable

9011 (INC x 2 ) 9270 CmSASCab4 (INC X 2) 9270CmSASCab3 (OPT) 9270CmSASCab5 (OPT)

9270 CmSASCab2 (INC X 1) 9270CmSASCab1 (OPT) 9270CmSASCab6 (OPT) 9270 CmSASCab3 (OPT) 9270CmSASCab4 (OPT) 9270CmSASCab5 (OPT)

9279CSlider36 (OPT)

9272CESlide28 (OPT) 9272CESlider36 (OPT)

DDRESCEMA (1GB, INC x 2) DDRESCMB (OPT)

DDRESCEMA (1GB, INC x 1) DDRESCMB (OPT)

DDRESCEMA (1GB, INC x 2) DDRESCMB (OPT)

DDRESCEMA (1GB, INC x 1) DDRESCMB (OPT)

Included x 2 9273CBTE (OPT)

9273CBTE (OPT)

Included x 2 9275CBTE (OPT)

9273CBTE (OPT)

QIG (INC) CD (INC x 2)

CD, Manual & Quick Installation Guide*7

* 1. Host-side dual-loop is supported by using multi-path software on the OS or EonPath to provide path redundancy. Drive-side dual-loop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dual-loops. * 2. SAS expansion ports connect SAS JBOD when there is a need to expand subsystem capacity. * 3. Single-UPG: Single RAID controller upgradable to redundant Redundant : Dual-Redundant controller configuration * 4. We do not recommend using 3rd-party memory module due to compatibility issues. Please contact Infortrend for compatible memory modules.

* 5. There two cache backup methods. One is battery backup, providing power to cache memory during power outages. Another is cache backup module, providing power to save cache memory data into a flash module during power outages. A cache backup module(CBM)consists of a BBU and Flash module. * 6. For details about rackmount kits, please refer to page 23. * 7. All hardware and software manuals are provided in PDF format in the product CD and SANWatch CD. The Quick Installation Guide (QIG) provides basic steps to set up and configure the subsystem and activate the software licenses. For detailed functions and settings, please refer to the hardware and software manual * 8. MUX board for SAS 6Gb/s drive side and SFF models is user-supplied. 11

All specifications are subject to change without prior notice.

9273CSlider32 (OPT) 9273CSlider36 (OPT)

Rack Mount Kits*6

BBU or CBM*5

9270 CmSASCab2 (INC X 2) 9270CmSASCab1 (OPT) 9270CmSASCab6 (OPT)

9270 CSASCab01 (OPT) 9270CSASCab02 (OPT)

Cable for SAS JBOD expansion

Cache Memory*4

9270 CmSASCab4 (INC X 1) 9270CmSASCab3 (OPT) 9270CmSASCab5 (OPT)


iSCSI to SAS RAID Subsystem The Infortrend EonStor DS iSCSI-host Series is designed to help SMB users leverage their existing investment on IP network to implement high-availability iSCSI SANs. With minimized additional costs and maintenance training, users can easily realize storage consolidation and in turn improve IT efficiency. In addition to fault-tolerant hardware designs, the data service functionalities such as snapshot and volume copy/mirror are available for EonStor DS Family. EonStor DS iSCSI-host Series is an ideal choice for SMBs to achieve enterprise-class availability while staying within stringent budgets.

S16E-R1130

S16E-G1130

S12E-R1132

S12E-G1133

iSCSI to SAS RAID Redundant Subsystems

iSCSI to SAS RAID Single Subsystems

iSCSI to SAS RAID Redundant Subsystems

iSCSI to SAS RAID Single Subsystems

Model

Rear View

3U-16 Bay

Form Factor Controller

2U-12 Bay ASIC400

12 Channels / 1 2 -bay SAS/SATA-II 3 Gb/s drives

16 Channels / 16-bay SAS/SATA-II 3 Gb/s drives

Drive Channels*1 Hot Swap Trays

4 Channels / GbE Four (4) RJ-45 ports per controller

4 Channels / GbE Four (4) RJ-45 ports per controller

2 Channels / GbE Four (4) RJ-45 ports per controller

2 Channels / GbE Two (2) RJ-45 ports per controller

Expansion Channels*2

Two (2) SAS 4x wide port (SFF-8088)

One (1) SAS 4x wide port (SFF-8088)

Two (2) SAS 4x wide port (SFF-8088)

One (1) SAS 4x wide port (SFF-8088)

Redundant Controller*3

Redundant Controller Enabled

-

Redundant Controller Enabled

-

Host Channels*1

RAID Function

RAID 0, 1, (0+1), 3, 5, 6,10, 30, 50, 60 with local spare, global spare, and enclosure spare drives Multiple RAID logical drives (LD), logical volumes (LV), partitions, host IDs, host LUNs, instant RAID ready, LD configuration on disks, dynamic host LUN mappings.

Advanced Functions

Host-side redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric log-in (supported on fibre-host models). Dual-mode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Auto-sync firmware and configuration on replacement controller

Management

LCD front panel: Easy-to-use tool for accessing system functions and features that does not require software installation or management server. RS-232 Terminal: User friendly menu-driven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including e-mail, LAN broadcast, SNMP trap, MSN and fax).

Management via Built-in LAN

Embedded RAIDWatch: Storage management, event notifications (e-mail, SNMP trap, etc.) via HTTP. Telnet-terminal: use- friendly menu for accessing all functions and features via telnet.

Hot Swap Cooling Modules

2 (Embedded in PSU)

Hot Swap Power Supplies

(2) x 530 W

2 (Embedded in PSU)

3

(2) x 530 W

(2) x 350 W

Cache Memory*4

1GB - 2GB DDR (PC-3200 DDR400)

Cache Backup*5

BBU

Variations & Spare Parts Controller Module

83SE11RE16DMA (INC x 2) 83SE11RE16DMB (OPT)

89SE11RE124DA (INC x 2) 89SE11RE124DB (OPT)

82SE11GE122DA (INC x 1) 82SE11GE122DB (OPT)

9279CFanMod (INC x 2)

9272CFanMod (INC x 3)

9273ECFanMod (INC x 2)

Fan Module Power Supply Module

Drive tray

83SE11GE16DMA (INC x 1) 83SE11GE16DMB (OPT)

9273ECPSU (INC x 2) 9373S1DT2S1S (INC x 16)

9373CDTray (INC x 16)

9279CPSU (INC x 2)

9272CPSU (INC x 2)

9373S1DT2S1S (INC x 12)

9373CDTray (INC x 12)

MUX board*8

9273S1N2S1S (OPT)

-

9273S1N2S1S (OPT)

-

RS-232C Cable

9270AYCab (INC x 1)

9270ASCab (INC x 1)

9270AYCab (INC x 1)

9270ASCab (INC x 1)

9270CUPSYCab (OPT)

9270CUPSCab (OPT)

9270CUPSYCab (OPT)

9270CUPSCab (OPT)

9270 CmSASCab1 (OPT) 9270CmSASCab2 (OPT) 9270CmSASCab6 (OPT)

UPS Cable RS-232C Null Modem

9011 (INC x 2 ) 9273CSTPCab (OPT )

Cable

9279CSlider36 (OPT)

9270 CmSASCab3 (OPT) 9270CmSASCab4 (OPT) 9270CmSASCab5 (OPT) 9272CESlide28 (OPT) 9272CESlide36 (OPT)

DDRESCEMA (1GB, INC x 2) DDRESCMB (OPT)

DDRESCEMA (1GB, INC x 1) DDRESCMB (OPT)

DDRESCEMA (1GB, INC x 2) DDRESCMB (OPT)

DDRESCEMA (1GB, INC x 1) DDRESCMB (OPT)

Included x 2 9273CBTE (OPT)

9273CBTE (OPT)

Included x 2 9275CBTE (OPT)

9273CBTE (OPT)

Rack Mount Kits*6 Cache Memory*4 BBU or CBM*5

QIG (INC) CD (INC x 2)

CD, Manual & Quick Installation Guide*7

* 5. There two cache backup methods. One is battery backup, providing power to cache memory during power outages. Another is cache backup module, providing power to save cache memory data into a flash module during power outages. A cache backup module(CBM)consists of a BBU and Flash module. * 6. For details about rackmount kits, please refer to page 23. * 7. All hardware and software manuals are provided in PDF format in the product CD and SANWatch CD. The Quick Installation Guide (QIG) provides basic steps to set up and configure the subsystem and activate the software licenses. For detailed functions and settings, please refer to the hardware and software manual * 8. MUX board for SAS 6Gb/s drive side and SFF models is user-supplied.

* 1. Host-side dual-loop is supported by using multi-path software on the OS or EonPath to provide path redundancy. Drive-side dual-loop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dual-loops. * 2. SAS expansion ports connect SAS JBOD when there is a need to expand subsystem capacity. * 3. Single-UPG: Single RAID controller upgradable to redundant Redundant : Dual-Redundant controller configuration * 4. We do not recommend using 3rd-party memory module due to compatibility issues. Please contact Infortrend for compatible memory modules.

12

All specifications are subject to change without prior notice.

9270 CmSASCab3 (OPT) 9270CmSASCab4 (OPT) 9270CmSASCab5 (OPT) 9273CSlider32 (OPT) 9273CSlider36 (OPT)

Cable for SAS JBOD expansion


EonStor DS Expansion Enclosure

Infortrend EonStor DS expansion enclosures deliver high reliability and density. Through SAS expansion ports, users can quickly and easily connect the enclosures to EonStor DS storage systems for flexible capacity expansion. The incremental approach of capacity scaling effectively satisfies growing application needs while reducing wasted upfront investment.

Model

S16S-J2000-R

S16S-J2000-S

S12S-J2000-R

S12S-J2000-G

SAS to SAS/SATA JBOD Subsystems

SAS to SAS/SATA JBOD Subsystems

SAS to SAS/SATA JBOD Subsystems

SAS to SAS/SATA JBOD Subsystems

Rear View

3U-16 Bay

Form Factor

2U-12 Bay

-

Controller

16 Channels / 16-bay SAS 6Gb/s / SATA-II 3Gb/s drives

Drive Channels*1 Hot Swap Trays

Host Channels*1

12 Channels / 1 2 -bay SAS 6Gb/s / SATA-II 3Gb/s drives

Expansion Channels*2

2 Channels / SAS 6Gb/s Two (2) SAS 4x wide ports (SFF-8088) per controller

Redundant Controller*3

-

RAID Function

RAID 0, 1, (0+1), 3, 5, 6,10, 30, 50, 60 with local spare, global spare, and enclosure spare drives Multiple RAID logical drives (LD), logical volumes (LV), partitions, host IDs, host LUNs, instant RAID ready, LD configuration on disks, dynamic host LUN mappings.

Advanced Functions

Host-side redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric log-in (supported on fibre-host models). Dual-mode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Auto-sync firmware and configuration on replacement controller

Management

LCD front panel: Easy-to-use tool for accessing system functions and features that does not require software installation or management server. RS-232 Terminal: User friendly menu-driven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including e-mail, LAN broadcast, SNMP trap, MSN and fax).

Management via Built-in LAN

Embedded RAIDWatch: Storage management, event notifications (e-mail, SNMP trap, etc.) via HTTP. Telnet-terminal: use- friendly menu for accessing all functions and features via telnet.

Hot Swap Cooling Modules

2 (Embedded in PSU)

2 (Embedded in PSU)

2

(2) x 530 W

(2) x 530 W

(2) x 350 W

85S20J122D (INC x 2)

82S20J122D (INC x 1)

Included

9279CFanMod (INC x 2)

9272CFanMod (INC x 3)

9373 CPSU (INC x 2)

9279CPSU (INC x 2)

9272CPSU (INC x 2)

Hot Swap Power Supplies Cache Memory*4

-

Cache Backup*5

-

Variations & Spare Parts Controller Module

83S20J162D (INC x 2)

83S20J162D (INC x 1)

Fan Module Power Supply Module

Drive tray MUX board*8

Cable

9373CDTray (INC x 16) 9373CMUX3GTRP (OPT)

9373CDTray (INC x 16)

9373CDTray (INC x 12) 9373CMUX3GTRP (OPT)

9373CDTray (INC x 12)

9373CMUX3G (OPT)

-

9373CMUX3G (OPT)

-

9270 CmSASCab1 (INC x 2) 9270CmSASCab2 (OPT) 9270CmSASCab6 (OPT)

9270 CmSASCab1 (INC x 1) 9270CmSASCab2 (OPT) 9270CmSASCab6 (OPT)

9270 CmSASCab1 (INC x 2) 9270CmSASCab2 (OPT) 9270CmSASCab6 (OPT)

9270 CmSASCab1 (INC x 1) 9270CmSASCab2 (OPT) 9270CmSASCab6 (OPT)

9373CSlider36 (INC)

CD, Manual & Quick Instillation Guide*7

QIG (INC) CD (INC x 1) * 5. There two cache backup methods. One is battery backup, providing power to cache memory during power outages. Another is cache backup module, providing power to save cache memory data into a flash module during power outages. A cache backup module(CBM)consists of a BBU and Flash module. * 6. For details about rackmount kits, please refer to page 23. * 7. All hardware and software manuals are provided in PDF format in the product CD and SANWatch CD. The Quick Installation Guide (QIG) provides basic steps to set up and configure the subsystem and activate the software licenses. For detailed functions and settings, please refer to the hardware and software manual * 8. MUX board for SAS 6Gb/s drive side and SFF models is user-supplied.

* 1. Host-side dual-loop is supported by using multi-path software on the OS or EonPath to provide path redundancy. Drive-side dual-loop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dual-loops. * 2. SAS expansion ports connect SAS JBOD when there is a need to expand subsystem capacity. * 3. Single-UPG: Single RAID controller upgradable to redundant Redundant : Dual-Redundant controller configuration * 4. We do not recommend using 3rd-party memory module due to compatibility issues. Please contact Infortrend for compatible memory modules.

13

All specifications are subject to change without prior notice.

Rack Mount Kits*6


EonStor DS Expansion Enclosure

• Various drive size options to suit your capacity requirements • Support both high-performance SAS drives and cost-effective SATA drives • Easy to deploy, install and manage • Shipped with standard warranty and provide extension options

Model

S16S-J1000-R

S16S-J1000-S

S12S-J1002-R

S12S-J1000-G

SAS to SAS/SATA JBOD Subsystems

SAS to SAS/SATA JBOD Subsystems

SAS to SAS/SATA JBOD Subsystems

SAS to SAS/SATA JBOD Subsystems

Rear View

3U-16 Bay

Form Factor

2U-12 Bay

-

Controller

16 Channels / 16-bay SAS/SATA-II 3 Gb/s drives

Drive Channels Hot Swap Trays*1

Host Channels*1 Expansion Channels*2

2 Channels / SAS 6Gb/s Two (2) SAS 4x wide ports (SFF-8470) per controller

12 Channels / 1 2 -bay SAS/SATA-II 3 Gb/s drives

2 Channels / SAS 6Gb/s Two (2) SAS 4x wide ports (SFF-8470) per controller

Redundant Controller*3

2 Channels / SAS 6Gb/s Two (2) SAS 4x wide ports (SFF-8088) per controller

2 Channels / SAS 6Gb/s Two (2) SAS 4x wide ports (SFF-8470) per controller

-

RAID Function

RAID 0, 1, (0+1), 3, 5, 6,10, 30, 50, 60 with local spare, global spare, and enclosure spare drives Multiple RAID logical drives (LD), logical volumes (LV), partitions, host IDs, host LUNs, instant RAID ready, LD configuration on disks, dynamic host LUN mappings.

Advanced Functions

Host-side redundant path and load balancing support (via EonPath software in Windows hosts or multipathing software on Linux and Solaris hosts); switched fabric support; fabric log-in (supported on fibre-host models). Dual-mode RAID expansion: Add drives or copy and replace with larger hard disk drive. Redundant models: Auto-sync firmware and configuration on replacement controller

Management

LCD front panel: Easy-to-use tool for accessing system functions and features that does not require software installation or management server. RS-232 Terminal: User friendly menu-driven for accessing all functions and features. SANWatch: Storage management suite (centralized system overview, storage management, notification manager including e-mail, LAN broadcast, SNMP trap, MSN and fax).

Management via Built-in LAN

Embedded RAIDWatch: Storage management, event notifications (e-mail, SNMP trap, etc.) via HTTP. Telnet-terminal: use- friendly menu for accessing all functions and features via telnet.

Hot Swap Cooling Modules

2 (Embedded in PSU)

2 (Embedded in PSU)

2

(2) x 530 W

(2) x 530 W

(2) x 460 W

89S10J122D(INC x 2)

85S10J12C2D (INC x 1)

9273ECFanMod (INC x 2)

9279CFanMod (INC x 2)

9275ECFanMod (INC x 2)

9273ECPSU (INC x 2)

9279CPSU (INC x 2)

9275ECPSU (INC x 2) 9373CDTray (INC x 12)

Hot Swap Power Supplies Cache Memory*4

-

Battery Backup*5

-

Variations & Spare Parts Controller Module Fan Module

83S10J162D (INC x 2)

Power Supply Module

Drive tray MUX board*8 Cable

Rack Mount Kits*6

83S10J162D (INC x 1)

9373S1DT2S1S (INC x 16)

9373CDTray (INC x 16)

9373S1DT2S1S (INC x 12)

9273S1N2S1S (OPT)

-

9273S1N2S1S (OPT)

9270 CmSASCab3 (INC x 2) 9270CmSASCab4 (OPT) 9270CmSASCab5 (OPT)

9270 CmSASCab3 (INC x 1) 9270CmSASCab4 (OPT) 9270CmSASCab5 (OPT)

9270 CmSASCab1 (INC x 2) 9270CmSASCab2 (OPT) 9270CmSASCab6 (OPT)

9270 CmSASCab3 (INC x 1) 9270CmSASCab4 (OPT) 9270CmSASCab5 (OPT)

9279CSlider36 (OPT)

9272CESlide28 (OPT) 9272CESlide36 (OPT)

9273CSlider32 (OPT) 9273CSlider36 (OPT)

-

* 5. There two cache backup methods. One is battery backup, providing power to cache memory during power outages. Another is cache backup module, providing power to save cache memory data into a flash module during power outages. A cache backup module(CBM)consists of a BBU and Flash module. * 6. For details about rackmount kits, please refer to page 23. * 7. All hardware and software manuals are provided in PDF format in the product CD and SANWatch CD. The Quick Installation Guide (QIG) provides basic steps to set up and configure the subsystem and activate the software licenses. For detailed functions and settings, please refer to the hardware and software manual * 8. MUX board for SAS 6Gb/s drive side and SFF models is user-supplied.

* 1. Host-side dual-loop is supported by using multi-path software on the OS or EonPath to provide path redundancy. Drive-side dual-loop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dual-loops. * 2. SAS expansion ports connect SAS JBOD when there is a need to expand subsystem capacity. * 3. Single-UPG: Single RAID controller upgradable to redundant Redundant : Dual-Redundant controller configuration * 4. We do not recommend using 3rd-party memory module due to compatibility issues. Please contact Infortrend for compatible memory modules.

14

All specifications are subject to change without prior notice.

QIG (INC) CD (INC x 1)

CD, Manual & Quick Installtion Guide*7


SAS to SATA RAID Subsystem Featuring multi-lane 3Gb/s SAS connectivity, ESDS A24S-G2130 provides a budget-friendly choice to help SMB users easily deploy high-availability DAS with abundant capacity. Through expansion enclosures, each ESDS A24S storage system can be scaled up to 88 SATA drives. When more capacity is required, users can further cascade the ESDS A24S with other A24S systems for a maximum capacity of 264 drives. In addition to capacity scalability, the ESDS A24S also provides advanced data protection and outstanding price/performance to support business-critical applications

A24S-G2130

Model

SAS to SATA RAID Single Subsystems

Rear View

4U-24 Bay

Form Factor

ASIC400

Controller Drive Channels*1 Hot Swap Trays

24 Channels / 24 -bay SATA - II 3 Gb / s drives

Host Channels*1

2 Channels / SAS 3Gb/s Two (2) SAS 4x wide ports (SFF-8088) per controller

Expansion Channels*2

One (1) SAS 4x wide port (SFF-8088)

Redundant Controller*3

-

RAID Function

RAID 0, 1, (0+1), 3, 5, 6,10, 30, 50, 60 with local spare, global spare, and enclosure spare drives Multiple RAID logical drives (LD), logical volumes (LV), partitions, host IDs, host LUNs, instant RAID ready, LD configuration on disks, dynamic host LUN mappings.

Advanced Functions

Host-side redundant path and load balancing supported (EonPath software required in the host computers) , switched fabric support, fabric log-in (supported on fibre-host model). Dual-mode RAID expansion "Add-in Drive" and "Copy & Replace with large drive" Redundant models: Auto-sync firmware and configuration on replacement controller

Management

LCD front panel: Easy-to-use menu for accessing all functions and features. RS-232 Terminal: User friendly menu-driven for accessing all function and feature. SANWatch: Storage management suite. (Storage management, central view, and Notification manager via e-mail, LAN broadcast, SNMP trap, MSN and fax)

Management via Built-in LAN

Embedded RAIDWatch: Storage management, event notifications (e-mail, SNMP trap, etc.) via HTTP. Telnet-terminal: User friendly menu-driven for accessing all function and feature via telnet.

Hot Swap Cooling Modules

3

Hot Swap Power Supplies

(3) x 405 W

Cache Memory*4

1GB - 2GB DDR (PC-3200 DDR400)

Cache Backup*5

BBU

Notes: * 1. Host-side dual-loop is supported by using multi-path software on the OS or EonPath to provide path redundancy. Drive-side dual-loop is supported by RAID controllers with Fibre Channel drive side connecting. RAID controller provides redundant path and dynamic load balancing across dual-loops.

Variations & Spare Parts Controller Module Fan Module Power Supply Module

Drive tray

84AS21GE24DMA (INC x 1) 84AS21GE24DMB (OPT)

9373CDTray (INC x 24) 9270ASCab (INC x 1)

UPS Cable

9270CUPSCab (OPT)

Cable for SAS JBOD expansion

9270 CmSASCab3 (OPT) 9270CmSASCab4 (OPT) 9270CmSASCab4 (OPT)

Rack Mount Kits*6

9373CSlider36 (INC)

Cache Memory*4

DDRESCEMA (1GB, INC x 1) DDRESCMB (OPT)

* 5. There two cache backup methods. One is battery backup, providing power to cache memory during power outages. Another is cache backup module, providing power to save cache memory data into a flash module during power outages. A cache backup module(CBM)consists of a BBU and Flash module. * 6. For details about rackmount kits, please refer to page 23. * 7. All hardware and software manuals are provided in PDF format in the product CD and SANWatch CD. The Quick Installation Guide (QIG) provides basic steps to set up and configure the subsystem and activate the software licenses. For detailed functions and settings, please refer to the hardware and software manual

9274CBTE (OPT)

* 8. MUX board for SAS 6Gb/s drive side and SFF models is user-supplied.

QIG (INC) CD (INC x 2)

15

All specifications are subject to change without prior notice.

Cable

CD, Manual & Quick Instillation Guide*7

* 4. We do not recommend using 3rd-party memory module due to compatibility issues. Please contact Infortrend for compatible memory modules.

9011 (ING x 1) 9270 CmSASCab2 (INC x 1) 9270CmSASCab1 (OPT) 9270CmSASCab1 (OPT)

BBU or CBM*5

* 3. Single-UPG: Single RAID controller upgradable to redundant Redundant : Dual-Redundant controller configuration

9274CPSU (INC x 3)

RS-232C Cable

RS-232C Null Modem

* 2. SAS expansion ports connect SAS JBOD when there is a need to expand subsystem capacity.

9274CFanMod (INC x 3)


High Capacity Guide

Fibre

Fibre Disk Based Combination 1:

F16F-R/S4031+ F16F-J4000-R

F16F-R/S4031 (3U, 16 Disks)

+

F16F-J4000-R (Up to 13 units)(3U, 16 Disks each)

=

Up to 224 Disks

Up to 42U Height

Configuration: CH0, CH1 Host channels; CH2, CH3, CH4, CH5 Drive expansion channels . Combination 2: F16F-R/S4031+

F16F-R/S4031 (3U, 16 Disks)

A16F-J2430-G

A16F-J2430-G (Up to 6 units)(3U, 16 Disks each)

+

=

Up to 112 Disks

Up to 21U Height

Configuration: CH0, CH1 Host channels; CH2, CH3, CH4, CH5 Drive expansion channels . Combination 3:

FF-R/S4030 (1U, no Disks)

FF-R/S4030+ F16F-J4000-R F16F-J4000-R (Up to 14 units)(3U, 16 Disks each)

+

=

Up to 224 Disks

Up to 43U Height

Configuration: CH0, CH1 Host channels; CH2, CH3, CH4, CH5 Drive expansion channels . Combination 4:

FF-R/S4031+ A16F-J2430-G

FF-R/S4031 (1U, no Disks)

+

A16F-J2430-G (Up to 6 units)(3U, 16 Disks each)

=

Up to 7U Height

Up to 96 Disks

Configuration: CH0, CH1 Host channels; CH2, CH3, CH4, CH5 Drive expansion channels . Combination 5:

F16F-R/S4840+ F16F-J4000-R

F16F-R4840 (3U, 16 Disks)

+

F16F-J4000-R (Up to 6 units) (3U, 16 Disks each)

=

Up to 112 Disks

Up to 21U Height

F16F-S4840 (3U, 16 Disks)

+

F16F-J4000-R (Up to 6 units) (3U, 16 Disks each)

=

Up to 112 Disks

Up to 21U Height

Cables and SFPs: 1. Fibre optical cables and SFPs are not included in the above models; they should be purchased separately. 2. At least 512MB cache memory is required in each RAID controller, when there are more than 96 disks in the configuration. 3. Host channels: Basically two LC-LC optical cables and four SFP modules. May vary by host connections. 4. Drive channels: Each F16F-J4000-R unit requires at least two LC-LC optical cables and four SFP modules. Accessories of SFP, and Cables 9270CSFP4GA01: Agilent Fibre Channel 4.25 / 2.125 / 1.0625 GBd Small Form Pluggable Optical Transceiver, LC, wave-length 850nm, multi-mode 9270CFCCab01: Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 1 Meter 9270CFCCab02: Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 5 Meter 9270CFCCab03: Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 10 Meter 9270CmSASCab1: SAS external cable, 50 cm(SFF-8088 to SFF-8088) 9270CmSASCab2: SAS external cable, 120 cm(SFF-8088 to SFF-8088) 9270CmSASCab3: SAS external cable, 50 cm(SFF-8470 to SFF-8088) 9270CmSASCab4: SAS external cable, 120 cm(SFF-8470 to SFF-8088) 9270CmSASCab5: SAS external cable, 170 cm(SFF-8470 to SFF-8088) 9270CmSASCab6: SAS external cable, 170 cm(SFF-8088 to SFF-8088) 9270CSASCab01: SAS external cable, 50 cm(SFF-8470 to SFF-8470) 9270CSASCab02: SAS external cable, 120 cm(SFF-8470 to SFF-8470)

SBODs Connections F16F-J4000-R Connecting to the RAID Controller's Drive Channels Drive Drive Channel-A Channel-B

Configuration: CH0, CH1 Host channels; CH2, CH3, CH4, CH5 Drive expansion channels . Combination 6: F16F-R/S4840+

F16F-R4840 (3U, 16 Disks) F16F-S4840 (3U, 16 Disks)

RAID System

A16F-J2430-G (SATA-II 3Gb/s Drives)

0

+

A16F-J2430-G (Up to 6 units) (3U, 16 Disks each)

=

Up to 112 Disks

Up to 21U Height

+

A16F-J2430-G (Up to 6 units) (3U, 16 Disks each)

=

Up to 112 Disks

Up to 21U Height

1 SBOD

Configuration: CH0, CH1 Host channels; CH2, CH3, CH4, CH5 Drive expansion channels .

2 SBOD

RAID Subsystem Connections 3

F16F-R4031

SBOD

F16F-S4031

4 SBOD

SBOD Chain 1 SBOD Chain 2

SBOD Chain 1 SBOD Chain 2

5 SBOD

6 SBOD

F16F-R4840 F16F-R4840

F16F-S4840 Exp. 2

Exp. 1

SBOD Chain 1 Chain 2 CH0

CH1

CH0

CH1

CH1

CH1

0

SBOD Chain 1 Chain 2 CH0

CH0

CH0

RAID System

CH1

1 SBOD

2 SBOD

FF-R4031

3

FF-S4031

SBOD

4 SBOD

SBOD Chain 1

SBOD Chain 1

5 SBOD Up to 6 SBODs (112 drives)

SBOD Chain 2

SBOD Chain 2

6 SBOD

Up to 7 SBOD Subsystems (FF-R/S4031) or up to 6 SBOD Subsystems (F16F) in a drive-side dual-loop 16


High Capacity Guide Fibre Disk Based S24F-R/G2840-4+ S16S-J2000-R/S

Combination 1:

S24F-R2840-4 (4U, 24 Disks) S24F-G2840-4 (4U, 24 Disks)

SAS Disk Based

+

S16S-J2000-R (Up to 5 units)(3U, 16 Disks each)

=

Up to 104 Disks

+

S16S-J2000-S (Up to 5 units)(3U, 16 Disks each)

=

Up to 104 Disks

Combination 2:

Co mbi na tion 11 : S16S-R/ G1 030

Up to 19U Height

S16S-R1030 (3U, 16 Disks)

Up to 19U Height

S16S-G1030 (3U, 16 Disks)

S24F-R/G1840-4/1440+ S16S-J1000-R/S

S24F-R1840-4/1440 (4U, 24 Disks)

S16S-J1000-R (Up to 5 units)(3U, 16 Disks each)

=

Up to 104 Disks

Up to 19U Height

S24F-G1840-4/1440 S16S-J1000-S + (Up to 5 units)(3U, 16 Disks each) (4U, 24 Disks)

=

Up to 104 Disks

Up to 19U Height

+

S16F-R2840-4 (3U, 16 Disks)

+

S16F-G2840-4 (3U, 16 Disks)

+

Combination 4:

S16S-J2000-R (Up to 6 units)(3U, 16 Disks each)

=

S16S-J2000-S (Up to 6 units)(3U, 16 Disks each)

=

Combina tion 5 : S16F-R/G1430

S12S-G1033 (2U, 12 Disks)

Up to 112 Disks Up to 112 Disks

Up to 21U Height

= =

Up to 112 Disks Up to 112 Disks

+

S12S-J1002-R Up to 48 Disks (Up to 3 units) (2U, 12 Disks each)=

Up to 8U Height

S12S-G1033 + S12S-J1000-G

+

S12S-J1000-G Up to 60 Disks (Up to 4 units) (2U, 12 Disks each) =

Up to 10U Height

S16E-R/G1130 + S16S-J1000-R/S

S16E-R1130 (3U, 16 Disks)

+

S16S-J1000-R Up to 64 Disks (Up to 3 units) (3U, 16 Disks each)=

Up to 12U Height

S16E-G1130 (3U, 16 Disks)

+

S16S-J1000-S (Up to 4 units) (3U, 16 Disks each)= Up to 80 Disks

Up to 15U Height

Up to 21U Height

Up to 12U Height

S16F-G1430 (3U, 16 Disks)

+

S16S-J1000-S (Up to 4 units) (3U, 16 Disks each)

=

Up to 80 Disks

Up to 15U Height

S12E-G1133 (2U, 12 Disks)

+

S12S-J2000-R (Up to 6 units)(2U, 12 Disks each)

=

Up to 84 Disks

Up to 14U Height

+

S12S-J2000-G (Up to 6 units)(2U, 12 Disks each)

=

Up to 84 Disks

Up to 14U Height

9270CSASCab01:SAS external cable, 50 cm (SFF-8470 to SFF-8470) 9270CSASCab02:SAS external cable, 120 cm (SFF-8470 to SFF-8470)

S12F-R/G1840-4/1440+S12S-J1002-R

S12S-R1840-4/1440 S12S-J1002-R + (Up to 6 units)(2U, 12 Disks each) (2U, 12 Disks)

=

Up to 84 Disks

9270CmSASCab1-SAS external cable, 50 cm (SFF-8088 to SFF-8088) 9270CmSASCab2-SAS external cable, 120 cm (SFF-8088 to SFF-8088) 9270CmSASCab3-SAS external cable, 50 cm (SFF-8470 to SFF-8088) 9270CmSASCab4-SAS external cable, 120 cm(SFF-8470 to SFF-8088) 9270CmSASCab5-SAS external cable, 170 cm(SFF-8470 to SFF-8088) 9270CmSASCab6-SAS external cable, 170 cm(SFF-8088 to SFF-8088)

Up to 14U Height

S12F-G1842-4/1440+S12S-J1000-G

S12S-G1842-4/1440 S12S-J1000-S + (Up to 6 units)(2U, 12 Disks each) (2U, 12 Disks)

=

Up to 84 Disks

Up to 14U Height

+ S12S-J1000-G

S12S-J1000-G (Up to 4 units) (2U, 12 Disks each)

=

Up to 60 Disks

Up to 10U Height

SAS Disk Based Co mb ination 10 : A24S-G2130

+

+ S16S-J1000-S (SAT A- II Dr ives)

S16S-J1000-S (Up to 4 units) (3U, 16 Disks each)

+ S12S-J1000-G

S12S-J1000-G Up to 60 Disks (Up to 4 units) (2U, 12 Disks each) =

Up to 10U Height

Accessories Cables 9270CSFP4GA01: Agilent Fibre Channel 4.25/2.125 / 1.0625 GBd Small Form Pluggable Optical Transceiver, LC, wave-length 850nm, multi-mode 9270CFCCab01: Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 1 Meter 9270CFCCab02: Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 5 Meter 9270CFCCab03: Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 10 Mete

Configuration: CH0, CH1 Host channels; CH2, CH3, CH4, CH5 Drive expansion channels .

+

+

Up to 8U Height

Configuration: CH0, CH1 Host channels; CH2, CH3, CH4, CH5 Drive expansion channels .

S12F-R/G2840-4+ S12S-J2000-R/G

Combina tion 9 : S12F-G1433

+

+ S12S-J1002-R

S12S-J1002-R Up to 48 Disks (Up to 3 units) (2U, 12 Disks each) =

Comb ination 16 : S12E-G1133

+ S16S-J1000-R/S Up to 64 Disks

A24S-G2130 (4U, 24 Disks)

S12S-R1032 + S12S-J1002-R

S12E-R1132 (2U, 12 Disks)

=

S12F-G1433 (2U, 12 Disks)

Up to 15U Height

Comb ination 15 : S12E-R1132

S16S-J1000-R (Up to 3 units) (3U, 16 Disks each)

Combination 8:

Up to 80 Disks

Up to 21U Height

+

Combination 7:

S16S-J1000-S (Up to 4 units) (3U, 16 Disks each) =

Combination 14 :

Up to 21U Height

S16F-R1430 (3U, 16 Disks)

S12F-G2840-4 (2U, 12 Disks)

+

S16F-R/G1840-4/1440+ S16S-J1000-R/S

S16F-G1840-4/1440 S16S-J1000-S + (Up to 6 units)(3U, 16 Disks each) (3U, 16 Disks)

S12F-R2840-4 (2U, 12 Disks)

Up to 12U Height

S16F-R/G2840-4+ S16S-J2000-R/S

S16S-R1840-4/1440 S16S-J1000-R + (Up to 6 units)(3U, 16 Disks each) (3U, 16 Disks)

Combination 6:

Up to 64 Disks

Comb ination 13 :

Configuration: CH0, CH1 Host channels; CH2, CH3, CH4, CH5 Drive expansion channels .

Combination 3:

+

Comb ination 12 :

S12S-R1032 (2U, 12 Disks)

+ S16S-J1000-R/ S

S16S-J1000-R (Up to 3 units) (3U, 16 Disks each) =

=

Up to 88 Disks

Up to 16U Height

17


High Capacity Guide S12E-R1132

S12E-G1133

S12S-G1033

S12F-G1440

CH0

JBOD Chain 1

JBOD Chain 1

CH1

JBOD Chain 1

JBOD Chain 1

JBOD Chain 2

S12F-R1432

S12S-R1032

S12F-G1433

JBOD Chain 1

JBOD Chain 1

JBOD Chain 1

JBOD Chain 2

S16E-R1130/S16E-G1130

S16F-R1430/S16F-G1430

S16S-R1030/S16S-G1030

JBOD Chain 1

JBOD Chain 1

CH1

CH1

JBOD Chain 1

JBOD Chain 2

JBOD Chain 2

6

JBOD Chain 1

JBOD Chain 1

CH0

S16F-R1440/S16F-G1440

JBOD Chain 1

JBOD Chain 2

3

CH0

JBOD Chain 1

JBOD Chain 2

JBOD Chain 2

S12F-R1440/S12F-G1440

A24S-G2130

JBOD Chain 1

JBOD Chain 1

S24F-R1440/S24F-G1440

S12F-R1840-4/S12F-G1840-4

S16F-R1840-4/S16F-G1840-4

JBOD Chain 1

JBOD Chain 1 JBOD Chain 2

JBOD Chain 1

JBOD Chain 1 JBOD Chain 2

JBOD Chain 2

JBOD Chain 2 CH0

CH1

JBOD Chain 1 JBOD Chain 1

JBOD Chain 1 JBOD Chain 1

S24F-R1840-4/S24F-G1840-4

S12F-R2840-4/S12F-G2840-4

CH0

CH1

CH2

CH3

CH0

CH1

CH2

CH3

S16F-R2840-4/S16F-G2840-4

S24F-R2840-4/S24F-G2840-4

Be sure every PSU should have the same mark

CH0

CH1

CH0

CH1

3Y 405W

CH2

CH3

CH2

CH3

Be sure every PSU should have the same mark

Be sure every PSU should have the same mark

3Y 405W

3Y 405W

1 0

JBOD Chain 1 JBOD Chain 2

JBOD Chain 1 JBOD Chain 2 CH0

CH1

CH2

JBOD Chain 1 JBOD Chain 2

JBOD Chain 1 JBOD Chain 2

CH3

CH0

JBOD Chain 1

JBOD Chain 1

Be sure every PSU should have the same mark

3Y 405W

CH1

CH2

CH3

Be sure every PSU should have the same mark

Be sure every PSU should have the same mark

3Y 405W

1 0

JBOD Chain 1

JBOD Chain 1

18

3Y 405W


High Capacity Guide S16F-R2840-4+S16S-J2000-R

CH1

CH0

CH1

CH0

CH1

CH0

CH1

RAID System CH0

S12F-R2840-4+S12S-J2000-R

CH0

CH1

CH0

CH1

RAID System CH0

S12F-R1440+S12S-J1002-R

S24F-G2840-4+S16S-J2000-S

S24F-R1840-4+S16S-J1000-R

RAID System

CH1

S12F-G1440+S12S-J1000-G RAID System

RAID System

S24F-G1840-4+S16S-J1000-S RAID System

RAID System

JBOD

JBOD JBOD

CH0

CH1

RAID System

RAID System

JBOD

CH1

S12F-G2840-4+S12S-J2000-S

RAID System

S24F-R2840-4+S16S-J2000-R

S16F-G1440+S16S-J1000-S

RAID System

RAID System CH0

S16F-R1440+S16S-J1000-R

S16F-G2840-4+S16S-J2000-S

JBOD

JBOD

JBOD JBOD JBOD

JBOD

JBOD JBOD JBOD

JBOD

JBOD

JBOD

JBOD

JBOD

JBOD JBOD

JBOD

JBOD

*ASIC400 model s: Up to 2 or 3 JBOD Subsy stems for R model , or 4 JBOD Subsy stem for G model , R model can be chai ned usi ng faul t-tolera nt links. 120cm SAS ext ern al cabl e is rec ommended *ASIC667 modes: Up to 6 JBOD Subsy stems for bot h R and G model s. 170cm SAS ext ern al cabl e is rec ommended.

19


High Capacity Guide S12S-R1032+S12S-J1002-R Connecting to the RAID Controller's Drive Channels

S12S-G1033+S12S-J1000-G

S12E-G1133+S12S-J1000-G

Connecting to the RAID Controller's Drive Channels

RAID System

Connecting to the RAID Controller's Drive Channels

RAID System

0

0

1

Connecting to the RAID Controller's Drive Channels

RAID System

RAID System

0

S12E-R1132+S12S-J1002-R

0

1

1

1

JBOD

JBOD

JBOD

JBOD

2

2

2

JBOD

JBOD

2 JBOD

JBOD

3 JBOD

S16S-R1030+S16S-J1000-R Connecting to the RAID Controller's Drive Channels

3

3

JBOD

JBOD

4

4

JBOD

JBOD

S16E-R1130+S16S-J1000-R

S16S-G1030+S16S-J1000-S

Connecting to the RAID Controller's Drive Channels

Connecting to the RAID Controller's Drive Channels

RAID System

RAID System

1

1

JBOD

JBOD

Connecting to the RAID Controller's Drive Channels RAID System

0

0

2

2

JBOD

JBOD

S16E-G1130+S16S-J1000-S

RAID System

0

0

3 JBOD

1

1

JBOD

JBOD

2

JBOD

2

JBOD

3

3

3

3

JBOD

JBOD

JBOD

JBOD

4

4

JBOD

JBOD

A24S-G2130+S16S-J1000-S

A24S-G2130+S16S-J1000-S Connecting to the RAID Controller's Drive Channels RAID System IN OUT

HBAs

A24S-G2130

0

1 JBOD

Controller A SFF-8088

2

SFF-8470

* A 120cm cable may be necessary

JBOD

Controller B S A S

SAS-IN

3

IN

S A S

S16S-J1000-S

• Both diagrams show one application server directly attached to three A24S RAID enclosures via the Cascade link. • A24S-G2130 provides additional Cascade ports that connect other three (3) A24S Enclosures. • The configuration supports up to 264 disk drives, including JBOD Connections.

SAS-OUT

OUT

JBOD

4 JBOD

*ASIC400 model s: Up to 2 or 3 JBOD Subsy stems for R model , or 4 JBOD Subsy stem for G model , R model can be chai ned usi ng faul t-tolera nt links. 120cm SAS ext ern al cabl e is rec ommended *ASIC667 modes: Up to 6 JBOD Subsy stems for bot h R and G model s. 170cm SAS ext ern al cabl e is rec ommended.

20


High Capacity Guide Accessories Cables 9270CSFP4GA01: Agilent Fibre Channel 4.25/2.125 / 1.0625 GBd Small Form Pluggable Optical Transceiver, LC, wave-length 850nm, multi-mode 9270CFCCab01: Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 1 Meter 9270CFCCab02: Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 5 Meter 9270CFCCab03: Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 10 Meter

2.5� SAS Disk Based Combination 1: B12F-R1430/G1431+ B12S-J1000-R/S

B12F-R1430 (1U, 12 Disks) B12F-G1431 (1U, 12 Disks)

B12S-J1000-R + (Up to 3 units) (1U, 12 Disks each) = Up to 48 Disks B12S-J1000-S + (Up to 4 units) (1U, 12 Disks each) = Up to 60 Disks

Up to 4U Height

9270CSASCab01:SAS external cable, 50 cm (SFF-8470) 9270CSASCab02:SAS external cable, 120 cm (SFF-8470)

Up to 5U Height

9270CmSASCab1-SAS external cable, 50 cm (SFF-8088) 9270CmSASCab2-SAS external cable, 120 cm (SFF-8088) 9270CmSASCab3-SAS external cable, 50 cm (SFF-8470-SFF-8088) 9270CmSASCab4-SAS external cable, 120 cm(SFF-8470-SFF-8088)

Combination 2: B12F-R1430+S12S-J1002-R & B12F-G1431+S12S-J1000-G

B12F-R1430 (1U, 12 Disks) B12F-G1431 (1U, 12 Disks)

S12S-J1002-R + (Up to 3 units) (2U, 12 Disks each) = Up to 48 Disks S12S-J1000-G + (Up to 4 units) (2U, 12 Disks each) = Up to 60 Disks

Up to 7U Height Up to 9U Height

RAID Subsyst em Conne ctions

Combination 3: B12F-R1430/G1431+S16S-J1000-R/S

B12F-R1430 (1U, 12 Disks) B12F-G1431 (1U, 12 Disks)

S16S-J1000-R + (Up to 3 units) (3U, 16 Disks each) = Up to 60 Disks S16S-J1000-S + (Up to 4 units) (3U, 16 Disks each) = Up to 76 Disks

B12F-R1430 Up to 10U Height

JBOD Chain2

Up to 13U Height JBOD Chain1

Combination 4 : B12S-R1030/G1031+B12S-J1000-R/S

B12S-R1030 (1U, 12 Disks) B12S-G1031 (1U, 12 Disks)

B12S-J1000-R + (Up to 3 units) (1U, 12 Disks each) = Up to 48 Disks B12S-J1000-S + (Up to 4 units) (1U, 12 Disks each) = Up to 60 Disks

B12F-G1431 Up to 4U Height JBOD Chain1

Up to 5U Height

B12S-R1030

Combination 5: B12S-R1030+S12S-J1002-R & B12S-G1031+S12S-J1000-G

B12S-R1030 (1U, 12 Disks) B12S-G1031 (1U, 12 Disks)

S12S-J1002-R + (Up to 3 units) (2U, 12 Disks each) = Up to 48 Disks S12S-J1000-G + (Up to 4 units) (2U, 12 Disks each) = Up to 60 Disks

JBOD Chain2

Up to 7U Height Up to 9U Height

JBOD Chain1

B12S-G1031

Combination 6: B12S-R1030/G1031+S16S-J1000-R/S

B12S-R1030 (1U, 12 Disks) B12S-G1031 (1U, 12 Disks)

S16S-J1000-R + (Up to 3 units) (3U, 16 Disks each) = Up to 60 Disks S16S-J1000-S + (Up to 4 units) (3U, 16 Disks each) = Up to 76 Disks

Up to 10U Height JBOD Chain1

Up to 13U Height

JBODs Connections B12F-R1430+B12S-J1000-R Connecting to the RAID Controller's Drive Channels

B12S-R1030+B12S-J1000-R Connecting to the RAID Controller's Drive Channels

RAID System

B12F-R1430+S12S-J1002-R

B12S-R1030+S12S-J1002-R

Connecting to the RAID Controller's Drive Channels

Connecting to the RAID Controller's Drive Channels

RAID System

0

0

1

JBOD

1 Link

Link

2

Link

JBOD

2

SAS-OUT

SAS-IN Link

Link

Link

Link

3

Link

3

SAS-OUT

SAS-IN Link

Link

Link

Link

B12F-R1430+S16S-J1000-R Connecting to the RAID Controller's Drive Channels RAID System

0 1 JBOD

Link

B12S-R1030+B12S-J1000-R+ S12S-J1002-R

B12S-R1030+S16S-J1000-R Connecting to the RAID Controller's Drive Channels

Connecting to the RAID Controller's Drive Channels

0 1 JBOD SAS-OUT

SAS-IN Link

Link

2 JBOD

3 JBOD

2 3 JBOD

* Up to 3 JBOD Subsyste ms for R model, or 4 JBOD Subsyste m for G model, R model can be chaine d using fau lt-toleran t links. *120cm SAS extern al cable is rec ommended

21

RAID System

0

0 1

1

JBOD

JBOD

2

2

JBOD

JBOD

SAS-OUT

SAS-IN Link

JBOD

B12S-R1030+B12S-J1000-R+ S16S-J1000-R Connecting to the RAID Controller's Drive Channels

RAID System

RAID System

Link

JBOD

SAS-OUT

SAS-IN Link

JBOD

SAS-OUT

SAS-IN Link

JBOD

3

SAS-OUT

SAS-IN

JBOD

JBOD

SAS-OUT

SAS-IN Link

JBOD

SAS-OUT

SAS-IN Link

2

SAS-OUT

SAS-IN Link

JBOD

JBOD

SAS-OUT

SAS-IN Link

JBOD

SAS-OUT Link

Link

1

SAS-OUT

SAS-IN Link

1

SAS-OUT

SAS-IN Link

SAS-IN

3

0

0

JBOD

2

RAID System

RAID System

Link


Shipping Package Dimensions

BTU & Amps

Air

590mm 23.23”

18kg 39.68lbs

-

43.5mm 1.71”

442mm 556.84mm 560.72mm 21.93” 22.06” 17.4”

15kg 33.07lbs

B12F-R1430 B12F-G1430 B12F-G1431 B12S-R1030 B12S-G1030 B12S-G1031 B12S-J1000-R B12S-J1000-S

220mm 780mm 30.7” 8.66”

590mm 23.23”

20.42kg 44.91lbs

24.26kg 53.48lbs

43.5mm 1.71”

445mm 504.81mm 528.3mm 15.1” 19.87” 20.79”

13.36kg 29.41lbs

1296 (380W) BTU/Hour

1.65A

Front to Rear

25.9kg 56.98lbs 23.6kg 52.03lbs 25kg 55.12lbs 25.5kg 56.22lbs

35.74kg 78.79lbs 33.44kg 73.72lbs 34.84kg 76.81lbs 35.34kg 77.91lbs

88mm 3.46”

446mm 17.56”

498mm 19.61” 486.7mm 19.61”

18.71kg 41.16lbs

1725 (530W) BTU/Hour

2.30A

Front to Rear

1381 (460W) BTU/Hour

1.75A

Front to Rear

32.34kg

41.44kg

1813 (530W) BTU/Hour

2.30A

1197 (350W) BTU/Hour

1.52A

1813(350W) BTU/Hour

2.30A

Front to Rear

2.29A

Front to Rear

1725 (530W) BTU/Hour

2.29A

Front to Rear

1643 (405W) BTU/Hour

2A

Front to Rear

S12S-G1033 S12E-G1133

B

C

390mm 780mm 15.35” 30.7”

570mm 22.44”

S12S-J1000-G S12F-R2840-4 S12F-R1840-4 S12F-R1440 S12S-J2000-R S12F-G2840-4 S12F-G1842-4 S12F-G1440 S12S-J2000-G F16F-R4840 F16F-S4840 F16F-R4031-4 S16S-R1030 S16E-R1130 S16S-J1000-R F16F-S4031-4 S16S-G1030 S16E-G1130 S16S-J1000-S S16F-R2840-4 S16F-R1840-4 S16F-R1440 S16S-J2000-R S16F-G2840-4 S16F-G1840-4 S16F-G1440 S16S-J2000-S A24S-G2130

4U

System Weight

210mm 780mm 30.7” 8.27”

S12S-J1002-R

3U

System Dimensions

FF-R4031 FF-S4031

A

S12S-R1032 S12E-R1132

2U

Shipping Wei ght with Subsystem and HDD

Maximum Maximum Heat Current at Airflow Dissipation 230V AC Direction (Estimated) (Estimated) 850 Front to (250W) 1.08A Rear BTU/Hour

Model

1U

Shipping Wei ght without Subsystem

S24F-R2840-4 S24F-R1840-4 S24F-R1440 S24F-G2840-4 S24F-G1840-4 S24F-G1440

515mm 779mm 20.28” 30.67”

564mm 779mm 22.20” 30.67”

460mm 780mm 18.11” 30.7”

564mm 779mm 22.20” 30.67”

597mm 23.5”

597mm 23.5”

580mm 22.83”

580mm 22.83”

642mm 779mm 25.28” 30.67”

597mm 23.5”

88mm 3.46”

E

F

445.6mm 498mm 19.61” 17.54”

Net weight

G*2

510.04mm 20.08” 514.3mm 20.25” 527.36mm 20.76”

15.7kg 34.61lbs 23.5kg 51.8lbs 17.6kg 38.8lbs

18.1kg 440mm 17.32”

90mm 8.54”

500mm 19.68”

42.54kg

36.22kg 79.85lbs

130mm 49.82kg 109.83lbs 5.12”

30.5kg 67.24lbs

43.62kg 96.17lbs

445mm 17.52”

497mm 19.57”

550mm 21.65”

20.56kg 45.33lbs 28.5kg 62.83lbs

445mm 17.52”

130mm 5.12”

488.2mm 499.88mm 17.57” 19.68”

29.5kg 65.04lbs

42.62kg 93.96lbs

27.5kg 60.63lbs

37.84kg

51.44kg

21.66kg 445mm 17.52”

130mm 5.12” 36.74kg

50.34kg

41kg 90.39lbs

60.68kg 133.78lbs

45.62kg

66kg

497mm 19.57”

550mm 21.65”

1725 (530W) BTU/Hour

20.56kg 45.33lbs 174.4mm 445mm 6.87” 17.52”

498mm 17.52”

520.66mm 20.50”

445mm 17.52”

498mm 19.61”

550mm 21.65”

38kg 83.78lbs 27.44kg

174mm 6.85” 44.52kg

Front to Rear

550mm 21.65” 17kg

31.24kg

597mm 23.5”

520mm 780mm 20.47” 30.7”

D

64.92kg

26.34kg

*1. Shipping weight includes subsystem weight, spare parts and accessares packages and outer carton weight. All weight information are estimated numbers. The actual weight can be varied with drives and configurations. *2. Subsystem width (deep) is from the back of chassis ear to the rear-end protrudings (PSU handles). For cube, subsystem height (desktop) and length (tower) both includes height and length of footplate. *3. Please allow 200mm (7.87inch) at the back and 50mm (1.97inch) in front of the subsystem for cabling and airflow

C

F A

Shipping Box

D

Subsystem

G B

E 22


Rackmount Kits for Subsystems 9276Cslider36 9277CSlider36 9272CESlide28/36 9273CSlider32/36 9274CSlider32/36 9279CSlider36 9373CSlider36

Model

FF-R4031 FF-S4031 B12F-R1430 B12F-G1431 B12S-R1030 B12S-G1031 B12S-J1000-R B12S-J1000-S S12E-G1133 S12S-G1033 S12S-J1000-G S12E-R1432 S12S-R1030 S12S-J1000-R S12F-R2840-4 S12F-G2840-4 S12F-R1840-4 S12F-G1842-4 S12F-R1440 S12F-G1440 S12S-J2000-R S12S-J2000-G S16F-R2840-4 S16F-G2840-4 S16F-R1840-4 S16F-G1840-4 S16F-R1440 S16F-G1440 F16F-R4840 F16F-G4840 S16S-J2000-R S12S-J2000-G S16E-R1130 S16E-G1130 S16S-R1030 S16S-G1030 F16F-R4031-4/6 F16F-S4031-4/6 A24S-G2130 S24F-R2840-4 S24F-G2840-4 S24F-R1840-4 S24F-G1840-4 S24F-R1440 S24F-G1440 Minimum Length (Pole-to-pole) *1

603.20mm (23.75 inches)

608 mm (23.94 inches)

600mm/650 mm (23.62/25.59 inches)

593 mm/601mm (23.35/23.66 inches)

593.40mm/601.50 mm (23.36/23.68 inches)

575 mm (22.64 inches)

609.6 mm (24 inches)

Maximum Length (Pole-to-pole) *1

917.30mm (36.11 inches)

920.70m m (32.25 inches)

730mm/930 mm (28.74/36.61 inches)

824mm/907 mm (32.44/35.71 inches)

812.80mm/914.40m m (32/36 inches)

916.20 mm (36.07 inches)

914.4 mm (36 inches)

Side View of Rack Cabin

Front Screw Pole Rear Screw Pole

Top View of Rack Cabinet Rear Screw Pole

Pole -to-pole Length

Pole-to-pole Length

1U Rail Kit

Subsystem

Subsystem Slide Rail Kit

Subsystem

Brackets

Front Screw Pole

23

* 1. The "pole-to-pole" length (or "post-to-post" length) is referring to the distance between the front screw hole pole (post) to the rear screw hole pole (post) in a rack cabin. A typical 900mm rack cabin often has pole-to-pole length of around 670 mm, and 800mm rack has around 615 mm.


®

SANWatch

SANWatch Storage Management Suite KEY FEATURES

OVERVIEW

• Applicable to Infortrend’s ESVA, EonStor DS and EonStor storage systems. • Java-based GUI provides graphical display of physical and logical RAID system components. • Centralized management of multiple arrays locally or remotely over LAN/WAN. • Complete RAID configuration functions for physical and logical storage components. • EonPath multi-path device and load-balancing configurations. • Event notification via Email, Fax, SNMP traps, LAN broadcast, MSN, and SMS messaging. • Collection of events from multiple systems to an administrator. • Event severity, type, and order filtering. • Connection view of multiple RAID systems showing either in-band or out-of-band connectivity. • Agent-based hierarchy for one-to-many manage-ment. • Automatically detects RAID systems within a network. • Export and restore system configuration profiles. • Supports many mainstream operating systems, including Windows, Solaris and Linux platforms. • SANWatch is shipped together with product packages. Licenses for additional software packages are separately purchased and activated.

SANWatch, Infortrend's storage management suite, provides all functions necessary to discover, configure, administer, and monitor Infortrend's storage solutions. SANWatch also provides management interfaces for EonPath, virtualization, snapshot, remote replication and more data service functions. SANWatch enables you to easily manage your storage and access all data protection and high-availability features through one easy-to-use interface.

TECHNICAL BRIEF SANWatch is a Java-based, cross-platform software management suite that provides support for many mainstream operating systems. Furthermore, SANWatch enables users to centrally manage their RAID systems, with all necessary management tools integrated into one single software suite. SANWatch features SSL (Secure Socket Layer) link protection and role-based access levels for management carried out on different installation sites and for different purposes. An administrator can also develop groups of managed systems based on their geographical or functional relationships.

SANWatch Centralized Management for Direct-Attached Storage (DAS) or Storage Area Network (SAN)

SANWATCH MANAGEMENT SUPPORTED PLATFORMS • Windows Sever 2003 R2 SP2 (32/64) • Windows Sever 2008 SP1 Enterprise / SP1 Enterprise cluster (32/64) • Windows Server 2008 SP2 Enterprise / Enterprise cluster (32) • Windows Server 2008 R2 / R2 cluster (64) • Windows Vista Ultimate • Windows 7 • Linux RHEL 5.2 & 5.3 (32/64) • Linux SUSE Enterprise Sever 10 SP2 (32/64) • Sun (Sparc) Solaris 10 • Apple Mac OS X 10.5

APPLICABLE MODELS • ESVA series • EonStor DS series • EonStor series

24


Warranty and Quality

Optional Extended Warranty In addition to the three-year Regular Warranty, Infortrend offers an Optional Extended Warranty (battery excluded) that extends the warranty period for the product an additional two years. Customers may purchase the Optional Extended Warranty at the time of sale or within the Regular Warranty period. For more detailed information, please contact your local representatives.

Quality System Infortrend is an ISO-9001:2000 and ISO-14001:2004 certified manufacturer known for its high quality standards. Our finished goods adhere to international standards including RoHS, Mil-std-105E, Mil-std-810F, IEC 60950, and IEC 17025. We have also passed prevalent company and product certifications, such as UL, CE, CB, BSMI, and FCC. Sound quality assurance is achieved through the following measures:

. Fully implemented TQM (Total Quality Methodology) and an automated shop floor control system . Serial-number-based product traceability from subsystems, modules, all the way down to the component level . In-house RoHS-compliance inspection starting from system design and SCM (Supply Chain Management) through mass production . Pre-pilot design verification and NPI (New Product Introduction) gate control procedures . 100 % burn-in and aging testing for quality control of mass production . Continual improvement in response to customer feedback

Our products are fully tested at all stages of manufacturing to verify they are stable and problem-free. All RAID systems come with a standard three-year warranty. As an option, customers may purchase a two-year extension to enjoy five-year worry-free warranty protection for their RAID systems.

1

40

01


w w w. i n f o r t r e n d . c o m

Americas Infortrend Corporation

Europe(EMEA) Infortrend Europe Ltd.

Germany Infortrend Deutschland GmbH

China Infortrend Technology, Ltd.

JAPAN Infortrend Japan, Inc. Asia Pacific Infortrend Technology, Inc.

Asia Pacific Infortrend Technology, Inc. 8F, No. 102, Sec. 3, Jhongshan Rd., Jhonghe City, Taipei County 23544, Taiwan Tel:+886-2-2226-0126 Fax:+886-2-2226-0020 sales.ap@infortrend.com support.ap@infortrend.com http://www.infortrend.com/taiwan

China Infortrend Technology, Ltd. Room 1210, West Wing, Tower One, Junefield Plaza, No. 6, Xuanwumen Street, Xuanwu District, Beijing, China. 100052 Tel:+86-10-63106168 Fax:+86-10-63106158 sales.cn@infortrend.com support.cn@infortrend.com http://www.infortrend.com/china

Japan Infortrend Japan, Inc. 6F Okayasu Bldg., 1-7-14 Shibaura, Minato-ku, Tokyo, 105-0023 Japan Tel:+81-3-5730-6551 Fax:+81-3-5730-6552 sales.jp@infortrend.com support.jp@infortrend.com http://www.infortrend.com/japan

Americas Infortrend Corporation 2200 Zanker Road, Shiue 130, San Jose, CA. 95131, USA Tel:+1-408-988-5088 Fax:+1-408-988-6288 sales.us@infortrend.com support.us@infortrend.com http://www.infortrend.com/americas

Europe Infortrend Europe Ltd. 1 Cherrywood, Stag Oak Lane Chineham Business Park Basingstoke, Hampshire RG24 8WF, UK Tel:+44-1256-707-700 Fax:+44-1256-707-889 sales.eu@infortrend.com support.eu@infortrend.com http://www.infortrend.com/europe

Germany Infortrend Deutschland GmbH Werner-Eckert-Str. 8 D-81829 Munich Germany Tel: +49 89 45 15 18 70 Fax: +49 89 45 15 18 765 sales.de@infortend.com support.eu@infortrend.com http://www.infortrend.com/germany

Š Copy right by Infortrend Technology, Inc.

Product quick reference guide_2010 v1.0


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.