Specifications VRV IV Heat Pump with continuous heating: RYYQ-T* Capacity range HP Cooling Nom. kW capacity Heating Nom. kW capacity Nom. kW Power input - Cooling 50Hz Heating Nom. kW EER ESEER COP Maximum number of connectable indoor units Min. Indoor index Nom. connection Max. HxWxD mm Dimensions Unit Weight Unit kg Sound power Cooling Nom. dBA level Sound pressure Cooling Nom. dBA level 째CDB Cooling Min.~Max. Operation range Min.~Max. 째CWB Heating Type Refrigerant Liquid OD mm Gas OD mm Piping OU IU Max. m Piping length connections Total piping System Actual m length Level OU - IU m difference Power supply Phase/Frequency/Voltage Hz/V Current Maximum fuse amps (MFA) A 50Hz
RYYQ8T 8
RYYQ10T 10
RYYQ12T 12
RYYQ14T 14
RYYQ16T 16
RYYQ18T 18
RYYQ20T 20
22.4
28.0
33.5
40.0
45.0
50.0
56.0
25.0
31.5
37.5
45.0
50.0
56.0
63.0
5.2 5.5 4.30 7.53 1 4.55
7.29 7.38 3.84 7.20 1 4.27
8.98 9.10 3.73 6.96 1 4.12
13.0 12.8 3.46 6.50 1 3.91
14.7 14.4 3.40 6.38 1 3.89
18.5 17.0 3.03 5.67 1 3.71
100 200 260
125 250 325 1,685x930x765
150 300 390
11.0 11.2 3.64 6.83 1 4.02 64 2 175 350 455
261
200 400 520
268
78
225 450 585 1,685x1,240x765
250 500 650
364
79
398
81
58
86
61
88
64
65
66
-5~43 -20~15.5 R-410A 12.7
9.52 19.1
15.9
22.2
28.6 165 3 1,000 3 90 3 Outdoor unit in highest position / 90 3 Indoor unit in highest position 3N~/50/380-415
20
25
32
40
50
(1) The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variable refrigerant temperature control operation) (2) Actual number of connectable indoor units depends on the indoor unit type (VRV indoor, Hydrobox, Split indoor, etc.) and the connection ratio restriction for the system (50% <= CR <= 130%) (3) Refer to technical specifications for more detail
OUTDOOR SYSTEM System
RYYQ22T
RYYQ24T
RYYQ26T
RYYQ28T
RYYQ30T
RYYQ32T
RYYQ34T
RYYQ36T
RYMQ10T
RYMQ8T
RYMQ12T
RYMQ12T
RYMQ12T
RYMQ16T
RYMQ16T
RYMQ16T
HP
RYMQ12T 22
RYMQ16T 24
RYMQ14T 26
RYMQ16T 28
RYMQ18T 30
RYMQ16T 32
RYMQ18T 34
RYMQ20T 36
kW
61.5
67.4
73.5
78.5
83.5
90.0
95.0
101.0
kW
69.0
75.0
82.5
87.5
93.5
100.0
106.0
113.0
kW kW
16.3 16.5 3.77 7.07 1 4.18
18.2 18.3 3.70 6.81 1 4.10
20.0 20.3 3.68 6.89 1 4.06
22.0 21.9 3.57 6.69 1 4.00
23.7 23.5 3.52 6.60 1 3.98
26.0 25.6 3.46 6.50 1 3.91
27.7 27.2 3.43 6.44 1 3.90
31.5 29.8 3.21 6.02 1 3.79
Outdoor unit module 1
Outdoor unit module 2 Capacity range Cooling Nom. capacity Heating Nom. capacity Nom. Power input - Cooling 50Hz Heating Nom. EER ESEER COP Maximum number of connectable indoor units Liquid OD Gas OD Piping Piping length OU - IU Max. connections Total piping System Actual length Level OU - IU difference Current Maximum fuse amps (MFA) 50Hz
64 2 mm mm m
15.9
19.1
28.6
34.9 165 3
41.3
m
1,000 3
m
90 Outdoor unit in highest position / 90 3 Indoor unit in highest position
A
63
3
80
(1) The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variable refrigerant temperature control operation) (2) Actual number of connectable indoor units depends on the indoor unit type (VRV indoor, Hydrobox, Split indoor, etc.) and the connection ratio restriction for the system (50% <= CR <= 130%) (3) Refer to technical specifications for more detail
OUTDOOR SYSTEM System
RYYQ38T
RYYQ40T
RYYQ42T
RYYQ44T
RYYQ46T
RYYQ48T
RYYQ50T
RYYQ52T
RYYQ54T
Outdoor unit module 1
RYMQ8T
RYMQ10T
RYMQ10T
RYMQ12T
RYMQ14T
RYMQ16T
RYMQ16T
RYMQ16T
RYMQ18T
Outdoor unit module 2
RYMQ10T
RYMQ12T
RYMQ16T
RYMQ16T
RYMQ16T
RYMQ16T
RYMQ16T
RYMQ18T
RYMQ18T
Outdoor unit module 3 HP
RYMQ20T 38
RYMQ18T 40
RYMQ16T 42
RYMQ16T 44
RYMQ16T 46
RYMQ16T 48
RYMQ18T 50
RYMQ18T 52
RYMQ18T 54
kW
106.0
112.0
118.0
124.0
130.0
135.0
140.0
145.0
150.0
kW
120.0
125.0
132.0
138.0
145.0
150.0
156.0
162.0
168.0
33.3 33.0
35.0 34.7
37.0 36.8 3.51 6.60 1 3.94 64 2 19.1 41.3 165 3
39.0 38.4 3.46 6.50 1 3.91
40.7 40.0 3.44 6.46 1 3.90
42.4 41.6 3.42 6.42 1 3.89
44.1 43.2 3.40 6.38 1 3.89
Capacity range Cooling Nom. capacity Heating Nom. capacity Nom. Power input - Cooling 50Hz Heating Nom. EER ESEER COP Maximum number of connectable indoor units Liquid OD Gas OD Piping length OU - IU Max. Piping connections Total piping System Actual length Level OU - IU difference Current - 50Hz Maximum fuse amps (MFA)
kW kW
31.0 29.9 3.42 6.36 1 4.01
30.9 3.61 6.74 1 4.05
3.54 6.65 1 4.00
mm mm m
6.62 1 3.98
m
1,000 3
m
90 Outdoor unit in highest position / 90 3 Indoor unit in highest position
A
3
100
125
Setting new standards in comfort and efficiency 48
Outdoor Units
OUTDOOR SYSTEM