Specifications VRV IV Heat Pump with continuous heating: RYYQ-T* Capacity range HP Cooling Nom. kW capacity Heating Nom. kW capacity Nom. kW Power input - Cooling 50Hz Heating Nom. kW EER ESEER COP Maximum number of connectable indoor units Min. Indoor index Nom. connection Max. HxWxD mm Dimensions Unit Weight Unit kg Sound power Cooling Nom. dBA level Sound pressure Cooling Nom. dBA level 째CDB Cooling Min.~Max. Operation range Min.~Max. 째CWB Heating Type Refrigerant Liquid OD mm Gas OD mm Piping OU IU Max. m Piping length connections Total piping System Actual m length Level OU - IU m difference Power supply Phase/Frequency/Voltage Hz/V Current Maximum fuse amps (MFA) A 50Hz

RYYQ8T 8

RYYQ10T 10

RYYQ12T 12

RYYQ14T 14

RYYQ16T 16

RYYQ18T 18

RYYQ20T 20

22.4

28.0

33.5

40.0

45.0

50.0

56.0

25.0

31.5

37.5

45.0

50.0

56.0

63.0

5.2 5.5 4.30 7.53 1 4.55

7.29 7.38 3.84 7.20 1 4.27

8.98 9.10 3.73 6.96 1 4.12

13.0 12.8 3.46 6.50 1 3.91

14.7 14.4 3.40 6.38 1 3.89

18.5 17.0 3.03 5.67 1 3.71

100 200 260

125 250 325 1,685x930x765

150 300 390

11.0 11.2 3.64 6.83 1 4.02 64 2 175 350 455

261

200 400 520

268

78

225 450 585 1,685x1,240x765

250 500 650

364

79

398

81

58

86

61

88

64

65

66

-5~43 -20~15.5 R-410A 12.7

9.52 19.1

15.9

22.2

28.6 165 3 1,000 3 90 3 Outdoor unit in highest position / 90 3 Indoor unit in highest position 3N~/50/380-415

20

25

32

40

50

(1) The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variable refrigerant temperature control operation) (2) Actual number of connectable indoor units depends on the indoor unit type (VRV indoor, Hydrobox, Split indoor, etc.) and the connection ratio restriction for the system (50% <= CR <= 130%) (3) Refer to technical specifications for more detail

OUTDOOR SYSTEM System

RYYQ22T

RYYQ24T

RYYQ26T

RYYQ28T

RYYQ30T

RYYQ32T

RYYQ34T

RYYQ36T

RYMQ10T

RYMQ8T

RYMQ12T

RYMQ12T

RYMQ12T

RYMQ16T

RYMQ16T

RYMQ16T

HP

RYMQ12T 22

RYMQ16T 24

RYMQ14T 26

RYMQ16T 28

RYMQ18T 30

RYMQ16T 32

RYMQ18T 34

RYMQ20T 36

kW

61.5

67.4

73.5

78.5

83.5

90.0

95.0

101.0

kW

69.0

75.0

82.5

87.5

93.5

100.0

106.0

113.0

kW kW

16.3 16.5 3.77 7.07 1 4.18

18.2 18.3 3.70 6.81 1 4.10

20.0 20.3 3.68 6.89 1 4.06

22.0 21.9 3.57 6.69 1 4.00

23.7 23.5 3.52 6.60 1 3.98

26.0 25.6 3.46 6.50 1 3.91

27.7 27.2 3.43 6.44 1 3.90

31.5 29.8 3.21 6.02 1 3.79

Outdoor unit module 1

Outdoor unit module 2 Capacity range Cooling Nom. capacity Heating Nom. capacity Nom. Power input - Cooling 50Hz Heating Nom. EER ESEER COP Maximum number of connectable indoor units Liquid OD Gas OD Piping Piping length OU - IU Max. connections Total piping System Actual length Level OU - IU difference Current Maximum fuse amps (MFA) 50Hz

64 2 mm mm m

15.9

19.1

28.6

34.9 165 3

41.3

m

1,000 3

m

90 Outdoor unit in highest position / 90 3 Indoor unit in highest position

A

63

3

80

(1) The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variable refrigerant temperature control operation) (2) Actual number of connectable indoor units depends on the indoor unit type (VRV indoor, Hydrobox, Split indoor, etc.) and the connection ratio restriction for the system (50% <= CR <= 130%) (3) Refer to technical specifications for more detail

OUTDOOR SYSTEM System

RYYQ38T

RYYQ40T

RYYQ42T

RYYQ44T

RYYQ46T

RYYQ48T

RYYQ50T

RYYQ52T

RYYQ54T

Outdoor unit module 1

RYMQ8T

RYMQ10T

RYMQ10T

RYMQ12T

RYMQ14T

RYMQ16T

RYMQ16T

RYMQ16T

RYMQ18T

Outdoor unit module 2

RYMQ10T

RYMQ12T

RYMQ16T

RYMQ16T

RYMQ16T

RYMQ16T

RYMQ16T

RYMQ18T

RYMQ18T

Outdoor unit module 3 HP

RYMQ20T 38

RYMQ18T 40

RYMQ16T 42

RYMQ16T 44

RYMQ16T 46

RYMQ16T 48

RYMQ18T 50

RYMQ18T 52

RYMQ18T 54

kW

106.0

112.0

118.0

124.0

130.0

135.0

140.0

145.0

150.0

kW

120.0

125.0

132.0

138.0

145.0

150.0

156.0

162.0

168.0

33.3 33.0

35.0 34.7

37.0 36.8 3.51 6.60 1 3.94 64 2 19.1 41.3 165 3

39.0 38.4 3.46 6.50 1 3.91

40.7 40.0 3.44 6.46 1 3.90

42.4 41.6 3.42 6.42 1 3.89

44.1 43.2 3.40 6.38 1 3.89

Capacity range Cooling Nom. capacity Heating Nom. capacity Nom. Power input - Cooling 50Hz Heating Nom. EER ESEER COP Maximum number of connectable indoor units Liquid OD Gas OD Piping length OU - IU Max. Piping connections Total piping System Actual length Level OU - IU difference Current - 50Hz Maximum fuse amps (MFA)

kW kW

31.0 29.9 3.42 6.36 1 4.01

30.9 3.61 6.74 1 4.05

3.54 6.65 1 4.00

mm mm m

6.62 1 3.98

m

1,000 3

m

90 Outdoor unit in highest position / 90 3 Indoor unit in highest position

A

3

100

125

Setting new standards in comfort and efficiency 48

Outdoor Units

OUTDOOR SYSTEM


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.