ACS355UM

Page 256

256 Actual signals and parameters

All parameters No. Name/Value Description 3420 OUTPUT3 MIN Sets the minimum display value for the signal selected by parameter 3415 SIGNAL3 PARAM. See parameter 3402 SIGNAL1 MIN. x‌x Setting range depends on parameter 3415 SIGNAL3 PARAM setting. 3421 OUTPUT3 Sets the maximum display value for the signal selected by MAX parameter 3415 SIGNAL3 PARAM. See parameter 3402 SIGNAL1 MIN. x‌x Setting range depends on parameter 3415 setting. 35 MOTOR TEMP MEAS 3501 SENSOR TYPE NONE 1 x PT100

2 x PT100 3 x PT100

Motor temperature measurement. See section Motor temperature measurement through the standard I/O on page 155. Activates the motor temperature measurement function and selects the sensor type. See also parameter group 15 ANALOG OUTPUTS. The function is inactive. The function is active. The temperature is measured with one Pt 100 sensor. Analog output AO feeds constant current through the sensor. The sensor resistance increases as the motor temperature rises, as does the voltage over the sensor. The temperature measurement function reads the voltage through analog input AI1/2 and converts it to degrees centigrade. The function is active. Temperature is measured using two Pt 100 sensors. See selection 1 x PT100. The function is active. Temperature is measured using three Pt 100 sensors. See selection 1 x PT100.

Def/FbEq -

-

-

NONE

0 1