ACS355UM

Page 162

162 Program features Note: The jogging speed overrides the constant speeds. Note: The jogging uses ramp stop even if parameter 2102 STOP FUNCTION selection is COAST. Note: The ramp shape time is set to zero during the jogging (ie linear ramp). Jogging function uses constant speed 7 as jogging speed and acceleration/deceleration ramp pair 2. It is also possible to activate jogging function 1 or 2 through fieldbus. Jogging function 1 uses constant speed 7 and jogging function 2 uses constant speed 6. Both functions use acceleration/deceleration ramp pair 2.

Settings Parameter 1010

Additional information Jogging activation

1208 1208/1207

Jogging speed Jogging speed for jogging function 1/2 activated through fieldbus Zero speed delay Acceleration and deceleration times Acceleration and deceleration ramp shape time: Set to zero during the jogging (ie linear ramp).

2112 2205, 2206 2207

Diagnostics Actual signal 0302

Additional information Jogging 1/2 activation through fieldbus

1401 1402/1403/1410

Jogging function status through RO 1 Jogging function status through RO 2…4. With option MREL-01 only.

1805

Jogging function status through DO