Pyro Panel Full Spec Sheet

Page 1

TM

Pyropanel™ is the first LED panel on the UK market to offer certified fire-safety compliance in addition to premium quality LED lighting. FIRST CHOICE IN FIRE-SAFE LED PANELS.

The correct specification and installation of LED lighting

Panels are a leading type of LED lighting readily

importance to ensure that building fire-safety is not

installed in suspended ceilings previously dominated by

compromised.

during both new build and renovation are of paramount

fluorescent lighting. Pyropanel™ is the first LED panel available in the UK LED technology offers compelling economic, health and

which has been tested according to BS476-22 and

environmental benefits which make it the light source

certified to offer 30 minutes fire-resistance when

of choice for new build and renovation of public and

correctly installed.

workplace buildings. As a premium LED panel, Pyropanel™ offers a low glare, Health and safety of people in public buildings and

low energy, low maintenance lighting solution backed

workplaces is protected by comprehensive legislation

by a 5-year manufacturer’s warranty.

and regulations. In particular, fire-safety is key part designed to retard the spread of fire through a

Pyropanel™ presents an advanced LED lighting option

building and allow the occupants to evacuate to safety.

for new construction and upgrade for existing buildings

Consequently, Building Regulations specifically

that complies with Building Regulations, fire-safety

mandate fire-resistance of building materials and

legislation and HSE guidance.

installed equipment.

Pyropanel™ has been tested in the UK according to BS476-22 and certified to offer 30 minutes fire-resistance when correctly installed. LED PANEL LIGHTING.

CHEAPER Low energy costs

In recent years, improvements in technology and cost

Long lifespan

have driven the rise of LED lighting to become the light

Low maintenance

source of choice for interior lighting. Its combination of benefits is truly compelling for both new build and upgrade of existing lighting installations.

HEALTHIER No flickering

In office, education and healthcare environments,

No ultraviolet

LED panels are popular replacements for ubiquitous

No infrared

fluorescent fittings in suspended ceilings. They enable public and private enterprises to enjoy the benefits of LED lighting and deliver on their emissions obligations by means of a readily-installed fitting.

GREENER Low carbon footprint Low energy consumption No mercury

© Brite Source Pte Ltd 2016


WHEN BUILDING REGULATIONS REQUIRE THAT A CEILING ACHIEVE A SPECIFIC FIRE-RESISTANCE, THE LIGHTING AND ALL OTHER FITMENTS WITHIN THE CEILING MUST ALSO BE CERTIFIED TO AN EQUAL FIRE-RESISTANCE.

THE CHALLENGE FOR LED PANEL LIGHTING. Lighting is often an integral component within ceiling

However, there are important fire-safety questions

structures. When building regulations require that a

concerning LED light panels; particularly those with

ceiling achieve a specific fire-resistance, the lighting

thermoplastic construction.

and all other fitments within the ceiling must also be certified to an equal fire-resistance; otherwise fire can quickly spread through lighting or fitments that offer less fire-resistance. This applies to both new build and renovation works.

• Are these LED panels certified fire-resistant to BS476-22? • Will their installation comply with Building Regulations? • Is fire-safety compliance maintained after installation? • Is fire insurance cover compromised after installation?

There are many fire-resistant LED lights that comply with Building Regulations and safety legislation.

IS IT CERTIFIED FIRE-SAFE?

BUILDING SAFETY LEGISLATION. All involved in the design, construction, maintenance

Resistance to fire is a key part of Building Regulations

and operations of commercial and public buildings

designed to slow the spread of flames through a

understand why they are subject to legislation and

building in case of fire, allowing the occupants sufficient

regulation.

time to evacuate to safety.

In the UK, people’s health and safety rightfully takes

In case of a fire incident, maintaining compliance with

precedence over all other considerations and has

fire-safety regulations can make the difference between

become embedded both within our culture,

life and death.

and within law. Important legislation and guidance for interior lighting is included in the following publications: • The Building Regulations (2013) Part B – Fire Safety. • Approved Document L2A. Conservation of fuel and power in new buildings other than dwellings. • Approved Document L2B. Conservation of fuel and power in existing buildings other than dwellings. • Regulatory Reform (Fire Safety) Order2005. • Health and Safety Executive HSG38 Lighting at Work. • The Construction (Design & Management) Regulations 2015.

© Brite Source Pte Ltd 2016


IF BUILDING WORK DOES NOT COMPLY WITH THE BUILDING REGULATIONS, THE BUILDING OWNER MAY BE SERVED WITH AN ENFORCEMENT NOTICE.

RESPONSIBILITY FOR COMPLIANCE. Building Regulations state; “People who are responsible

“If building work does not comply with the Building

for building work; for example the owner, agent,

Regulations, the building owner may be served with an

designer, builder or installer, must ensure that the

enforcement notice.”

work complies with all applicable requirements of the Building Regulations.”

ENFORCEMENT. The main enforcing authority for the Regulatory Reform (Fire Safety) Order 2005 will normally be the local Fire and Rescue Authority. However there are some special areas where others have been appointed as the enforcing authority. These are listed in detail in article 25 of the Order. Building Control Bodies (BCB) are responsible for enforcing standards and ensuring compliance with Building Regulations. There are 2 types: • Local Authority Building Control. • Approved Inspector Building Control. Since 2002, Government has additionally established Competent Persons Schemes to allow individuals and enterprises to self-certify that their work complies with the Building Regulations as an alternative to submitting

SINCE 2002, GOVERNMENT HAS ESTABLISHED A COMPETENT PERSONS SCHEME TO ALLOW INDIVIDUALS AND ENTERPRISES TO SELF-CERTIFY THAT

a building notice or using an approved inspector. Enforcement of the Construction Design & Management Regulations (2015) depends on building occupancy during construction works.

THEIR WORK COMPLIES WITH THE

CDM2015 - is enforced by the HSE when the building is

BUILDING REGULATIONS.

unoccupied and by the Local Fire and Rescue Authority when the building or a part of the building under construction is occupied.

© Brite Source Pte Ltd 2016


Choose Safety, Choose Pyropanel™ KEY FEATURES.

SAFETY.

ECONOMY.

• Tested in the UK and certified

• Complies with Building Regulations

fire-resistant to BS476-22.

Part L (2014).

• Complies with Building Regulations Part B (2013).

• Robust construction and Philips driver allow us to offer a 5-year warranty.

• Self-test and conventional emergency lighting options available.

• Energy Saving – Up to 60% compared to fluorescent.

• 3 hour emergency version available.

• Occupancy and lux control available.

• CE certified.

• Addressable version available for BMS. • Low maintenance, long lifetime.

ENVIRONMENT.

HEALTH.

• Eco-friendly design.

• Low glare (UGR < 19) in compliance with

• Low energy consumption.

EN12464-1 Lighting of indoor workplaces.

• Reduced CO2.

• High quality light: good colour rendition,

• Zero mercury.

no flickering, no UV, no IR.

• RoHS compliant.

• Popular light colours available: cool white (4000K), daylight white (6000K). • Dimmable option.

Key Data Dimensions Colours Colour Rendition (CRI) CCT Range

Luminous Flux

596x596x11mm Daylight White (6000K) Cool White (4000K) Ra80 4000K: 3700-4200K

TM

6000K: 5700-6300K 4000K: 3600lm 6000K: 3700lm

Beam Angle

103°

Dimmable

Optional DALI/triac dimming

Power Input (50-60Hz AC)

48w, 220-240VAC, 50-60Hz

Power Factor, Current

0.92, 1150mA

Lamp Type

2835 SMD

Working Temperature

-20 ~ +40°C

Construction

PC/AL/Steel

IP Rating

IP20

Certification

CE, RoHS, BS476-22

Energy Efficiency Label

A

Energy Consumption (Ec)

48 kWh / 1000 hrs

T:

0844 251 2382

Lifetime

50,000 hours

E:

safe@pyropanel.co.uk

Warranty and LMF at EoL

5 Years, 70%

Switching Cycles

100,000

W:

www.pyropanel.co.uk

© Brite Source Pte Ltd 2016

(30 mins)

CONTACT US.