Agenda 

Company Overview & Product Portfolio

S2600

T- Series Storage

N8000 NAS

Case studies

Service & Support

Q & A.

Huawei Symantec Technologies Co., Ltd.

page 2


About Huawei Symantec Technologies Co. Ltd. Name History Location Ownership

Huawei Symantec Technologies Co. Ltd. (Huawei Symantec) Established in May 2007. Officially listed in February 2008 Headquartered in Chengdu, China. The company has 7 regional divisions in China and around the world, covering over 100 countries Huawei Technologies Co.,Ltd. (Huawei): 51% Symantec Corporation (Nasdaq: SYMC): 49%

Management

John W. Thompson, Chairman of Symantec & Chairman of the HS Board Ren Zhengfei, CEO of Huawei and CEO of HS Technologies

Business

The JV develops and manufactures world leading storage and security products for businesses worldwide, and delivers end-to-end solution and service sets

Operation

4500 employees, $300M turnover (2009), $505M in 2010

Huawei Symantec Technologies Co., Ltd.

page 3


Key Success Factors

Targeted Synergies

Huawei Strengths Top 3 comprehensive telecom solutions providers International reach to over 100 countries Partner with 36 of the world’s top 50 carriers

 World-class R&D force and customer service capability  Inherits highly reliable and scalable system capability from Huawei  Inherits years' experience and knowledge in information security and storage from Symantec

Sales 25%

Service 10%

Admin Mkt 5% 5% R&D 55%

Huawei Symantec Technologies Co., Ltd.

page 4

Symantec Strengths World leading security and storage software technology Comprehensive portfolio of security and storage solutions Customers include 99% of Fortune 1000 companies


EU Storage Customers of Huawei

Enterprise Customers

… OEM Customers

… Huawei Symantec Technologies Co., Ltd.

page 5


Storage Lineup

New Product Strategy: CDC

• Fast connection (8Gb FC, 10GE, 6Gb SAS2.0) • SSD, SAS HDD application

High-End Storage

Integrated Application

• Extended portfolio

Appliance Storage

S12000

Application

High Performance Large Capacity Unified Storage Best Cost Effectiveness

New VIS

VTL S8000

SAN Storage HDP

SSS S2600

S5500T S5800T S6800T S5600T New

N8300

N8500

New Implementation

Huawei Symantec Technologies Co., Ltd.

page 6

New


Introducing the S2600

12 bay 2U storage

Single or Dual controllers

Multiple connectivity options

Modular chassis with Hot Swap components

Expandable to 96 Drives via D120 expansion chassis

Supported raid configurations RAID 0, 1, 5, 6 ,10, & 50

Huawei Symantec Technologies Co., Ltd.

page 8


Controller / Chassis options •Single or Dual Controller •Choice of Host Interface •4 x FC ports per controller •4 x GbE iSCSI ports per controller •2 x 4Gb FC & 2 x GbE iSCSI ports per controller •2 x 8Gb FC & 2 x GbE iSCSI ports per controller •2 Mini SAS ports per controller •Choice of cache size (2 or 4GB per controller *) •Up to 12 hard drives per enclosure (either SAS and/or SATA and or SSD**) •Up to 7 expansion D120 units via mini SAS connections •Total of 96 drives per array •Dependent on host interface ** Maximum 6 SSD’s supported

Huawei Symantec Technologies Co., Ltd.

page 9


World Best IOPS/Drive Performance (S2600)

http://www.storageperformance.org/results

Huawei Symantec Technologies Co., Ltd.

page 10

Page 10


Oceanspace S2600 Users Challenge - Lack of backup performance - High investment in expansion

Oracle

SQL Server

Exchange

Lotus

Solution - HyperImage combine with backup software,

realizes quick backup; - The green technology of Oceanspace S2600 reduces power consumption.

IP SAN/FC SAN

Benefit

Data replication

- Low investment; LUN1

- Shot backup time;

LUN2

- Low power consumption;

- Easy expansion.

Huawei Symantec Technologies Co., Ltd.

Third party storage

page 11

S2600/S5000


Agenda 

Company Overview & Product Portfolio

S2600

T- Series Storage

HDP3500

N8000 NAS

Case studies

Service & Support

Q & A.

Huawei Symantec Technologies Co., Ltd.

page 12


Overview Market Positioning 

Designed for the mid-range and high-end storage markets. Meets the requirements of large databases (OLTP and OLAP), high performance computing, centralized storage, data backup, disaster recovery, and data migration, thus effectively ensuring the security and continuity of services for customers.

Hardware Architecture 

Adopts the latest PANGEA hardware platform. S5500T: integration of the controller and disks (2U controller enclosure) S5600T/S5800T/S6800T: separation of the controller and disks (4U independent engine) Active-active redundancy dual controllers

Huawei Symantec Technologies Co., Ltd.

page 13

S5500T

S5600T/S5800T/S6800T


Overview Product Features 

High performance:  PCIE2.0 high-speed bus and SAS2.0 high-speed I/O channel  SmartCache technology High reliability:  Dual plane power supply  Built-in BBU + data coffers  Various data protection technologies Powerful scalability:  Hot-swappable I/O modules  The S6800T can be expanded up to 1,440 disks and 192 GB cache. Green features:  CPU frequency control  Intelligent fan speed adjustment  Disk spin-down

Huawei Symantec Technologies Co., Ltd.

page 14

S5500T

S5600T/S5800T/S6800T


T-Series Performance at a Glance

Huawei Symantec Technologies Co., Ltd.

page 15


Hot Swap and Online Expansion of I/O Modules Hot Swap and Online Expansion of I/O Modules

Introduction 

I/O moduless can be replaced and expanded online without interrupting services. Before hot swapping an I/O module, a user can press the indicator button to make the I/O modulesstop working. In this way, security of hot swap is ensured.

1. 2.

Press the indicator button of the I/O modulesto stop the work of the I/O modules. The system releases resources occupied by the I/O module. Wait until the running indicator is off, and then replace the I/O modules.

Technical Advantages 

More flexible networking: Multiple types of networking, such as FC SAN, IP SAN, and FC+IP SAN, through combination of different I/O modules. Online expansion for lower cost: According to the incremental services, I/O modules can be expanded online for more available ports. In this way, additional switching

devices are not needed, and therefore the cost is reduced. I/O modulesTypes -

8 Gbit/s FC I/O modules with four ports GE I/O modules with four ports 10GE I/O modules with two ports 4x6 Gbit/s SAS I/O modules with two ports 4 Gbit/s FC I/O modules with four ports

Huawei Symantec Technologies Co., Ltd.

page 16

8Gb FC


Work Principle of SmartCache 1. 2.

3.

5.

If the SmartCache pool contains all the data that a host wants to read, the host reads data from the pool.

If the pool does not contain all the data that a host wants to read, the host reads data from the HDD. hotspot data in the SmartCache pool is updated synchronously with the source data on the HDDs.

Huawei Symantec Technologies Co., Ltd.

3 ncy

ncy 24

LUN1 1 LUN1 2 2 LUN1 1

23 2 5

24 15 11

LUN1 2 LUN1 3 LUN2 3 LUN2 2

12 2 11

11 12 10

LUN1 3 4 LUN2 4 LUN1 3

32 1 24

10 11 5

5 LUN2 4

LUN2 LUN1 1

2 1 3

10 5

6 LUN2 5

LUN1 LUN2 2

1 1 10

5 3

LUN2 6

LUN2 3

3 1

1

1

Every half hour, the system sorts these data blocks according to the access frequencies. The system copies data blocks that rank higher in the list to the SmartCache pool. If data blocks that originally have copies in the pool still keep their positions in the ranking, no update is made.

7.

Rank LUN No.LUNBlock No. No. Blockfreque No. freque

When hosts read data from HDDs, the system counts the access frequency of data blocks on LUNs for which SmartCache is enabled, and creates a list to record the access frequency of these data blocks.

4.

6.

Work Principle of SmartCache

Divides SSDs to blocks and number each block. The default block size (not user-definable) is 1 MB.

page 17

LUN1

12

3

9

6

HDD

HDD

HDD

1

2

3

LUN1

1

3

11

22

3

LUN2

2

4

SSD

SSD


Agenda

Company Overview & Product Portfolio

S2600

T- Series Storage

HDP3500

N8000 NAS

Case studies

Service & Support

Q & A.

Huawei Symantec Technologies Co., Ltd.

page 18


HDP3500 specification Oceanspace HDP3500 Processor

1*Intel 4 core processor (can be expanded to 2)

Cache

4GB(can be expanded to 32GB)

Host Interface

2*GE(can be expanded to 6*GE)

Archive Interface

1*4Gb FC or 1*3GB SAS (used to connect the tape library)

Max disk number

24

Disk type

1TB/2TB SATA

RAID

RAID 0,1,5,6

Protocol Advanced function

Oceanspace HDP3500

NFS、CIFS、iSCSI、FTP、HTTP Data Deduplication、Snapshot、Distribute File system namespace, (DFS-N) 、Distribute File system replication (DFS-R) Quotas

Disk hot/plug in Hardware

support Power/FAN

redundancy

Huawei Symantec Technologies Co., Ltd.

page 19


NAS & Storage “All-in-one” IP SAN

NAS

IP

IP

IP

IP

NFS/CIFS/FTP/ AppleTalk/HTTP

IP

IP

iSCSI

File level access

Block level access Oceanspace HDP3500

NAS and IP SAN-based integration, to build a unified storage platform, adapted to different application characteristics ▬ Provide multi-protocol file services, NFS, CIFS, iSCSI, FTP, HTTP

Huawei Symantec Technologies Co., Ltd.

page 20


Agenda 

Company Overview & Product Portfolio

S2600

T- Series Storage

HDP3500

N8000 NAS

Case studies

Service & Support

Q & A.

Huawei Symantec Technologies Co., Ltd.

page 21


N8000 Clustered Storage Product Appearance

Oceanspace TM N8300 integrated storage system

Huawei Symantec Technologies Co., Ltd.

Oceanspace TM N8500 integrated storage system

page 22


Introduction of N8000 Item

N8300

N8500

Num of NAS engine

2-6

4-16

Clustering mode

Active-Active

Cache

Each engine 8/16GB

Interface of network

4-6 GE/engine, 2 10GE/engine

Interface of FC Max.capacity

Disk type

Huawei Symantec Technologies Co., Ltd.

4-6GE/engine

2*4Gb /engine 7.68PB

15PB

FC:,300GB (15k RPM), 450GB(15k RPM),600GB(15k RPM) SAS: 300GB (15k RPM), 450GB(15k RPM), 600GB(15k RPM) SATA:1TB (7.2k RPM),2TB(7.2k RPM) SSD:100GB(SLC)

page 23


Specifications Item

N8300

N8500

Protocols supported Network protocol support

FC, iSCSI, CIFS, NFS, NDMP,

Management protocols

SSH, SNMP,NIS, DNS, NTP, Email Alerts

File system attributes Multi-protocol support

Simultaneous CIFS and NFS

Maximum file system size

256TB

Maximum files per system

Up to 200 million

RAID striping

Automated Parallel RAID Striping and Multi-Pathing

Backup attributes NDMP support

yes

Backup type

Support Clustered Symantec Netbackup client for SAN and LAN Connectivity

System management RAID controller management NAS management Management interfaces

N8000 ISM GUI, Command Line Interface(CLI)

Standard Features

Dynamic storage tiering、Snapshot、Mirror、Clustered Veritas NetBackup Client

Huawei Symantec Technologies Co., Ltd.

page 24


Huawei Symantec Technologies Co., Ltd.

page 25


Unified storage File servers

Application servers

Database servers

iSCSI

NFS/CIFS

FC

Block-level access

File-level access Applicable to requirements that requires lots of bandwidth

NAS IP SAN FC SAN

N8000 Cluster NAS

Huawei Symantec Technologies Co., Ltd.

page 26


N8000 Clustered NAS System • Multiple value-added functions CIFS/NFS Client

IP

– DST dynamic hierarchical storage – Integration of the NBU client to implement the server-free backup – Snapshot

• Multi-dimensional and flexible

N8000 Clustered NAS System

expansion NAS Engines Install/Upgrade

– Capacity – Performance – File system

• High reliability

FC Storage Units

– Active-active mode – Automatic failover and failback

• Protocol support – NFS V2/V3 – CIFS Huawei Symantec Technologies Co., Ltd.

page 27


N8000 Series Storage Architecture •

NAS engine architecture –

Active-active cluster architecture

The nodes communicate with one another through the high-speed private network.

Oceanspace N8000

Engine node automatic failover –

Any node can be the master node.

The master node monitors the working status of the clustered engine.

DNS Load Balancing

Through the private network, the master node can identify a failed node or any node that is added to or disconnected from the cluster.

NAS node

Storage controller

Through the DNS server, the load is balanced between multiple nodes in the NAS cluster, hence preventing a single node from overheating.

Huawei Symantec Technologies Co., Ltd.

NAS node

Failover Redundant power supplies Redundant fans Redundant UPS’s

Load balancing –

NAS node

page 28

NAS node

Storage controller


Savenet & Datastore 365 Case Studies Integrated Data Center

ISP LAN Pepsi Lotus

Typical Scenario Coca-cola

Storage Space host: Internet Service Provider host storage space for file sharing, data backup and remote recovery; Cloud Storage

Huawei Symantec Technologies Co., Ltd.

page 29


Agenda 

Company Overview & Product Portfolio

S2600

T- Series Storage

HDP3500

N8000 NAS

Case studies

Service & Support

Q & A.

Huawei Symantec Technologies Co., Ltd.

page 30


OmniPay Case study Business Need Need a reliable hardware solution to facilitate larger and more scalable virtual server deployments for actual use within office environment. Solution The solution consisted of: IBM X3850 X5 (64GB RAM, 2 x 4 port 10/100/100 NIC for ISCSI connections, 2 x 4 core cpu) and the Huawei Symantec S2600 storage systems with 8TB of available storage. Results Storage solution brings considerable options that are only found in high end storage System. Storage system enhances the ability to deploy servers that are fit for purpose at a greater speed to better meet business need. Storage solution saves on procurement and engineering setup time to meet the business need in an efficient manner. “The Huawei Symantec storage array punches above its weight, is highly scalable, very resilient with dual PSU and dual controllers, can be configured for iSCSI or FC, has energy efficient disk spin down capabilities and optional data replication capabilities to a sister device. Most of these options are generally available only on highere nd systems.” Production Support Manager of OmniPay David O’Brien Huawei Symantec Technologies Co., Ltd.

page 31


Londonderry Ports Case study Business Need A new data storage solution to enhance their IT infrastructure to deal with growing data and meet expanded business needs. Solution The solution comprised of a managed S2600 storage system and 2 TB of available storage. The SAN was coupled with an ML350 Server from HP running VMware essentials. On the VMware environment there are four different servers running SBS 2008, Ericom Weconnect, A Full ERP Implementation and Maintenance Management System. As a result of this install the port are now saving over £2000 per year in Server running costs and have future proofed all storage needs for the foreseeable future. Results The storage solution addresses the immediate business requirement with good performance and in a highly cost effective way. The solution provides strong future scalability capability. “We are extremely happy with our decision to adopt a new brand technology from the market place. The Huawei Symantec solution has delivered on all counts.” IT Director of Londonderry Port, Mark Doherty Huawei Symantec Technologies Co., Ltd.

page 32


Agenda 

Company Overview & Product Portfolio

S2600

T- Series Storage

HDP3500

N8000 NAS

Case studies

Service & Support

Q & A.

Huawei Symantec Technologies Co., Ltd.

page 33


Warranty / Maintenance Options

Standard warranty ▬

3 years hardware warranty, no SLA

SLA available ▬

Silver 

8 x 5, Next business day

Gold 

24 x 7, 4 hour response

Huawei Symantec Technologies Co., Ltd.

page 34


Thank you

Any Questions ? Huawei Symantec Technologies Co., Ltd.

page 35


Coffee Break

Please feel free to contact us

Sales Technical

jon.reeves@huaweisymantec.com martin.cooper@huaweisymantec.com www.huaweisymantec.com

Huawei Symantec Technologies Co., Ltd.

Huawei Symantec Confidential


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.