Content:
Load Cells
Page
Dynamometer Wireless Remote Display for Dynamometer Mechanical Overload Switch Static Line Tensiometer Heavy Duty Tensiometer Running Line Tensiometer Offshore Dynamometer Shackle Pin Load Pin Junction Box S Cell Compression Cell Pressure Transducer Bellows Bending Beam ET Stainless Series Bolt-on Bin Lift Silo Mount Shear Beam Button Cell Annular Load Cell
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
Display and Amplifier Options
Page
Amplifier Panel Meter Display Large Display Remote Control
22 23 24 25
Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
Option
Option
ATEX
ATEX ATEX ATEX
OIML
ATEX ATEX ATEX ATEX ATEX
OIML OIML
ATEX
OIML
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
V-LINK Dynamometer 670601, 671201, 672501, 675501 • Highly accurate and reliable, ±0,2% FS accuracy. • Very clear red digit LED display. Visible at long distances / in bright daylight. • IP Class 67. Ideal for wet/humid environments. • Robust high strength steel construction for use in hostile environments. • Supplied with full certificate of calibration. • Delivered in smart carry case from hard ABS plastic. • Designed and manufactured in DK for high quality assurance. Specifications: Application: Capacity: Accuracy: Safe overload: Materials: IP class: Display: Digit height: Digit color: Operating time: Operation temp.: Batteries: Charger:
Crane and hoist calibration and proof load testing 6.5T, 12T, 25T, 55T ±0,2% FS 110% High strenght steel housing. Fe/Zn12/A surface treatment according to ISO 2081 IP 67 Bright LED 14 mm Red 16-20 hours (Operating at low temperatures will decrease the operating time) -20°C - +50°C Build-in Li-on High quality USB charger
Item No:
Capacity (T) A (mm) B (mm) C (mm) D (mm) E (mm) Ø (mm) Weight (kg.) Increment (kg.)
670601 671201 672501 675501
6.5 12 25 55
200.00 200.00 230.00 282.00
115.00 115.00 115.00 115.00
117.00 117.00 117.00 155.00
260.00 281.00 338.00 440.00
41.50 41.50 41.50 46.00
31.00 37.30 54.00 73.00
4.47 5.65 7.56 16.93
5 10 10 20
Accessory options: WRDTX01
Wirless remote display
1 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Remote Display, Wireless WRDTX01 • Handheld display for V-LINK Dynamometer. • Enables measurements to be read from long distances and moving objects. • Up to 99 Dynamometers with remote display can be used in the same area. • Very easy to use. Highly reliable and comfortable.
Specifications: Application areas: Range: Number of channels: Standard frequency: Communication form: RF output power: IP class: Operating time: Operating temp.: Batteries: Charger:
For use with V-LINK Dynamometer only 150 meters in free range 99 869.750 Mhz Duplex 10 mW IP65 16-20 hours From -20°C - +50°C Build-in LI-ON Standard USB charger, (used for V-LINK)
Item No:
Dimensions
Weight (kg.)
WRDTX01
H145 x L88 x W23 mm
0.15
2 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Mechanical Overload Switch SM4067, SM4068 • Designed for load limitation of hoisting devices and cranes. • The compact size provides a minimal lifting height reduction. L150 mm. • Quick and precise installation with simple tools. • Can easily be adjusted to fit different wire types and capacities. • Linear force development gives a user-friendly reaction pattern. • Available with 1 or 2 cut off points. • Designed and manufactured in DK for high quality assurance. Specifications: Application areas:
• Load limitation of hoisting devices, cranes and overhead cranes. Suitable for a variety of industrial environments, including high-temperature and dusty environments. • Can be used for low and high weights limits.
Materials:
Item No:
Housing: Nickel plated steel. Springs: Heat treated spring steel, according to GB/T 13304. Axles: CK45. Max 4% FS 0 to 80°C. Below 0°C a heating device is recommended. UI: 500V UL Listed. Utilisator: AC-15:230V/4A IEC 60947-5-1 DC-13: 24V / 1A Wire Capacity Weight Dimensions
SM4067-2 SM4067-4 SM4067-6
6-13 mm 6-13 mm 6-13 mm
500-1500 kg. per reeving 1500-3000 kg. per reeving 3000-5000 kg. per reeving
2,45 kg. 2,80 kg. 3,15 kg.
W70 x H145 x L150 W70 x H145 x L150 W70 x H145 x L150
SM4068-2 SM4068-4 SM4068-6
13-20 mm 13-20 mm 13-20 mm
500-1500 kg. per reeving 1500-3000 kg. per reeving 3000-5000 kg. per reeving
2,45 kg. 2,80 kg. 3,15 kg.
W70 x H145 x L150 W70 x H145 x L150 W70 x H145 x L150
Hysteresis: Operating temp.: Switch:
3 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Static Line Tensiometer WT1-N, WT2-N • Combined load indication and load limitation system for hoisting devices, cranes and overhead cranes. • Electronic clamp-on tensiometer, universal fit. • Highly accurate and reliable, ±1% FS accuracy. • Minimal lifting height reduction. Down to L100 mm. • Quick and easy to install on the dead end of the wire rope. • Designed and manufactured in DK for high quality assurance. Specifications: Accuracy: On unit: Mounted: Output: Material: Temperature: Input: Cable:
± 1% FS 0.1% FS 0.1% x wire diameter x2. 2.0 Nom MV/V balanced signal. Alu 7075 0,0011 MV/C EXC. 5-10 VDC 3 mtrs. (Up to 15 mtrs. as option)
Item No:
Wire (mm)
Capacity (T)
Dimensions (mm)
Weight (kg.)
WT1-N WT2-N
6-15 mm 14-28 mm
5T per reeving 10T per reeving
L100 x W62 x H65 L138x W80 x H85
0.8 kg. 1.5 kg.
Complete systems: WT1-N + OL3000A WT1-N + P1001, D1002, D1004
Tensiometer + Amplifer (load limitation only) Tensiometer + Display w. Amplifer (load indication and limitation)
WT1-N
WT2-N 4
Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Heavy Duty Tensiometer WT3 • Combined load indication and load limitation system for hoisting devices and cranes with large wires. • Electronic clamp-on tensiometer, universal fit. • Highly accurate and reliable, ±1% FS accuracy. • Fully welded stainless steel construction. • Quick and easy to install on the dead end of the wire rope. • Supplied with 10 mtrs. cable. Specifications: Full Load Output: Zero Load Output: Excitation (Max): Accuracy: Repeatability: Input Resistance: Output Resistance: Compensated Temp. Range: Operating Temp. Range: Temp. Coefficient on Zero: Temp. Coefficient on Span: Safe Overload: Insulation: IP Class: Item No:
1.0 nom mV/V <±5.0% 10 (15) V ±1% FS <0.25% 375 (±20) Ω 350 (±2) Ω -10° to 40°C -20° to 60°C <0.0010%Capacity/°C <0.0010%Capacity/°C 150% >500 @ 100Vdc MΩ IP68 Wire (mm)
Capacity (kg.)
Dimensions (mm)
WT3-27-28 WT3-29-32 WT3-33-35 WT3-36-38 Complete systems:
27-28 29-32 33-35 36-38
9700 12600 15100 17900
L230 x H116 L230 x H116 L230 x H116 L230 x H116
WT3 + OL3000A WT3 + P1001, D1002, D1004
Tensiometer + Amplifer (load limitation only) Tensiometer + Display w. Amplifer (load indication and limitation)
5 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Running Line Tensiometer RLT • Combined load indication and load limitation system for moving wires. • Accuracy down to 1%. • Heavy duty ball bearing construction. • Hardened stainless load pin. • 3 standard housing models. • Wide assortment of mounting accessories. • Available in galvanised steel for corrosive environments. Specifications: Capacity: Wire size: Output signal: IP Class: Relative humidity: Operating Temp.: Item No:
1-1000T 13-38 mm 1mv/v at full load IP67 >98% -20°C to +60°C. Under 0°C a heating device is recommended. Wire (mm) A (mm) B (mm) C (mm) Weight (kg.)
RLT13 RLT16 RLT19 RLT22 RLT25 RLT28 RLT32 RLT35 RLT38 Complete systems:
13 16 19 22 25 28 32 35 38
RLT + OL3000A RLT + P1001, D1002, D1004 RLT PAYOUTCOUNTER Mounting Arm:
Tensiometer + Amplifer (load limitation only) Tensiometer + Display w. Amplifer (load indication and limitation) Payout counter. Wire (mm) D (mm) E (mm) Weight (kg.)
RTL MOUNTINGARM1 RTL MOUNTINGARM2 RTL MOUNTINGARM3
13-19 22-28 32-38
720 720 720 810 810 810 963 963 963
810 850 850
225 225 225 270 270 270 297 297 297
1270 1320 1320
180 180 180 186 186 186 188 188 188
14.5 21.5 21.5 37 37 37 56 56 56
11 11 15
6 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Offshore Dynamometer D2000E • Robust aluminium construction. Very compact size. • Highly accurate and reliable, ±0.5% FS accuracy. • Environmentally sealed to IP66. IP67 as option. • Transmission distance up to 200 m. • For use with standard Crosby or Green Pin shackles. The Dynamometer is as standard provided with handheld display and suitcase. Specifications: Radio Frequency: Accuracy: Input Resistance: Output Resistance: Compensated Temp. Range: Operating Temp. Range: Temp. Coefficient on Zero: Temp. Coefficient on Span: Safe Overload: Ultimate Overload: Insulation: Battery Life: Item No: Capacity (T)
2,4 GHz ±0,05% FS 800 Ω 700 Ω -10° to 40°C -20° to 60°C <0,005 %FRO/°C <0,003 %FRO/°C 150% 400% >500 @ 100Vdc MΩ Up to 200 hours. A (mm) B (mm)
C (mm)
DØ (mm)
E (mm)
Weight (kg.)
D2000E-12T-S D2000E-25T-S D2000E-35T-S D2000E-50T-S D2000E-100T-S D2000E-150T-S D2000E-200T-S D2000E-250T-S
120 131 147 170 228 300 325 365
41,5 55 55 75 120 120 159 189
38 53 60 73 100 110 135 145
239 284 335 375 500 550 660 720
2.0 4.5 5.5 10.0 28.0 50.0 75.0 90.0
12 25 35 50 100 150 200 250
105 125 138 150 220 260 290 304
7 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Shackle Pin SHA-PIN • Robust stainless steel pin & bobbin for use in hostile environments. • Highly accurate and reliable, ±0.5% FS accuracy. • Bobbin and anti-rotation bracket for centralized, accurate loading. • Green Pin shackles. Crosby shackles as option. • 4-20 mA output. • Telemetry and cabled version, 10 mtrs cable. To ensure the right fit shackles and load pins are always provided together. Specifications: Full load output: Zero load output: Excitation (Max): Input resistance: Output resistance: Compensated temp. Range: Operating temp. Range: Temp. Coefficient on Zero: Temp. Coefficient on Span: Insulation: Capacity: (T) A (mm)
2.0 nom. mV/V <±2.0 % 10 (15) V 375 or 745 Ω 350 or 750 Ω -10° to 40°C -20° to 60°C <0.005 %Capacity/°C <0.003 %Capacity/°C >500 @100Vdec MΩ B (mm) C (mm)
Accuracy: Repeatability: Safe overload: IP class:
D (mm)
L (mm)
T (mm)
3,25 (only cabled) 6,5 12 25 35 42,5 55 85 120 150 250
40 54 76 106 127 134 142 163 203 229 305
19 25,4 35 50 57 65 70 83 95 108 127
57 84 119 146 187 212 267 309 368 371 475
27 38 50 73 83 95 105 127 133 140 215
75 100 146 216 238 287 311 355 420 460 625
16 22 32 45 51 57 68 75 89 100 115
±0.5% FS <0.10% 150% IP66
8 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Load Pin LOADPIN-18000 • Combined load indication and load limitation system for hoisting devices, cranes and overhead cranes. • Designed according to customers specifications as direct replacement for load bearing pins in lifting equipment. • Provides the highest accuracy within weighing, ±0.1% FS accuracy. • Robust stainless steel construction. IP68.
Specifications: Capacity: Proof load: Ultimate breaking load: Bridge resistance: Excitation: Output: Non-linearity: Non-repeatability: IP class: Operating temp.: Temp. Coefficient on Zero: Temp. Coefficient on Span: Signal cable:
0.1 to 1000T 150 % of rated load 500 % of rated load 350/700/1000 ohms 5 to 10 volts (dc) 1.0 to 1.5 mV/V ±1 % typical ±0.04 % optimum IP67 -20° to 70° C <0.02 % Capacity/°C <0.02 % Capacity/°C 5 mtrs. Polyurethane 4 core
Complete systems: LOADPIN + OL3000A LOADPIN + P1001, D1002
Tensiometer + Amplifer (load limitation only) Tensiometer + Display w. Amplifer (load indication and limitation)
Options: ∙ Special anti-rotation / locking plates ∙ Second redundancy gauge bridge ∙ Internal signal amplifier ∙ Single shear pins fully welded ∙ Submersible ∙ Internal greaseways plug / socket breakdown at pi
9 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Junction Box JB02C-4-WB • Junction Box fitted with electronic board for junction and equalisation of 4 and 6 load cells. • Fully encapsulated, water proof and moisture proof. • Easy connection of the load cells. • Not weight dependant.
Specifications: Material: Load cell output resistance range: Load cell input resistance range: Excitation, recommended voltage: Excitation, maximum: Load cell sensitivity range: Cable Ø: Correction method: Trimming range: Temperature range, operating: Housing connected to shield: External grounding: IP Class:
Cast aluminium housing. Protective coasting. 340 to 1100 Ω 340 to 1100 Ω 5 to 20V (AC&DC) 30V (AC&DC) 0.6 - 3 mV/V 5 to 6.2 mm Excitation trim 24 Ω -40° to 85°C Yes No IP65
Item No:
Amount of connections
Dimensions (mm)
JB02C-4-WB
4
135 x 65 x 38
10 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
S Cell S-CELL • Suitable for hanging, hopper and other weighing devices. • Tension and compression applications. • Stainless steel construction. • Highly accurate and reliable. • IP 68.
Specifications:
C3
OIML R60 C3
Output sensitivity (= FS): Max. Numbr of load cell intervals: Ratio of min. LC verification interval: Combined Error: Min. dead load: Safe overload: Ultimate overload: Zero balance: Excitation, recommended voltage: Excitation maximum: Input resistance: Output resistance: Insulation resistance: Compensated temperature: Operating temperature: Storage temperature: Item No: Capacity
2.0 ± 0.008 mV/V
2.0 ± 0.004 mV/V
Output
W (mm)
H (mm)
≤±0.0230 %FS 0% 150% 300% ≤± 1.5% FS 5 to12 V 18 V 350 ± 3 Ω 350 ± 3 Ω ≥5000 (at 50VDC) MΩ -10 to 40 °C -35 to 65 °C -40 to 70 °C Diameter (mm) M (mm)
S-CELL500KG-Z1 S-CELL1000KG-Z1 S-CELL2000KG-Z1 S-CELL5000KG-Z1
2mV/V 2mV/V 2mV/V 2mV/V
32 32 32 50
25 25 25 24
Ø99 Ø99 Ø99 Ø99
0.5T 1T 2T 5T
3000 7500
12000
M12 x 1.75 M12 x 1.75 M20 x 1.5 M24 x 2
11 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Compression Cell COMP • Suitable for high precision applications such as dosing systems, machines and other scale applications. • Stainless steel construction. Welded cover. • Highly accurate and reliable. ±0.25% accuracy. • Low weight. • Integral load button.
Specifications: Full load output: Zero load output: Excitation (Max): Accuracy: Repeatability: Input resistance: Output resistance: Compensated temp.: Operating temp. Range: Temp. Coefficient on zero: Temp. Coefficient on span: Safe overload: Insulation: IP class: Item No: Capacity (T)
2.0 (±0.25%) mV/V <±2.0% 10 (15) V <0.25% <0.1% 750 (±20) Ω 700 (±2) Ω -10 to 50 °C -20 to 70 °C <0.005 % capacity/°C <0.005 % capacity/°C 150% >500 @ 100Vdc MΩ IP68 H (mm) B (mm) W (mm)
R (mm)
D (mm)
T (mm)
P (mm)
COMP0,5T COMP1T COMP2T COMP5T COMP10T COMP20T
21 21 35 35 35 35
50 50 150 150 150 150
Ø59 Ø59 Ø98 Ø98 Ø98 Ø98
M3x7 M3x7 M6x18 M6x18 M6x18 M6x18
42 42 72 72 72 72
0.5 1 2 5 10 20
4 4 5 5 5 5
10 10 20 20 20 20
12 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Pressure Transducer PRESSTRANS • Economical pressure measurement. • Sealed gauge operation. • Resistant to transients and spikes. • Robust stainless steel construction. • IP 67
Specifications: Capacities: Full load output: Zero balance: Excitation (max): Accuracy: Repeatability: Input resistance: Output resistance: Compensated temp. Range: Operating temp. Rage: Temp. Coefficient on zero: Temp. Coefficient on span: Safe overload: Insulation: Cable length:
50, 100, 200, 250, 350, 500, 700, 1000 bar. 2.0 nom. mV/V <±5.0% 10 (12) V <0.2% <0.10% 350Ω 350Ω -10 to 40 °C -20 to 60 °C <0.040 % Capacity/°C <0.040 % Capacity/°C 150% >500 @100Vdc MΩ 4 mtrs.
Item No: PRESSTRANS100B Options: ∙ Other ranges and non-standard sizes available on request ∙ Cable or plug and socket ∙ Connector ∙ Amplified outputs (voltage or current)
13 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Bellows Bending Beam BELLOWSBEAM • Suitable for belt and tank weighing, bag fillers and platforms. • Range 10-200 kg. • Stainless steel construction, 17/4/PH. • Hermetically sealed. Fully welded. • 4 mtrs. Screened polyurethane cable. • Easy installation.
Specifications: Rated output: Accuracy class: Combined error: Non repeatability: Creep 30 mins: Temp. effect on zero: Temp. effect on span: Compensated temp. Range: Operating temp. Range: Safe overload: Ultimate overload: Zero balance: Input resistance: Output resistance: Insulation resistance: Supply voltage (nominal): Max voltage:
2 ±0.1% mV/V 3000 n.OIML <±0.017% <±0.015% <±0.016% <±0.001%/ °C <±0.001%/ °C -10 to 40 °C -20 to 60 °C 150% 200% <1% 400±20 Ω 350±3 Ω >5000 MΩ@100VDC 10 V 15V
Item No:
ØA
ØB
C
D
E
F
ØG
BELLOWSBEAM
42 ØH
34 J
20 K
24.5 L
53.5 M
42 N
8.2 P
27
10
82
120
18
10
30
14 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
ET Stainless Series TD • Highly accurate and reliable, ±0.1% FS accuracy. • Robust high strength steel construction for use in hostile environments. • For use with standard shackles. • Sealed to IP 68. • Supplied with 10 mtrs. Cable and full certificate of calibration.
Specifications: Full Load Output: Zero Load Output: Excitation (Max): Repeatability: Input Resistance: Output Resistance: Compensated Temp. Range: Operation Temp. Range: Temp. Coefficient on Zero: Temp. Coefficient on Span: Safe Overload: Insulation: Item No: Capacity (T)
1 (nominal) mV/V <±2.0% 10 (15) V <0.05% 375 (±20) Ω 350 (±2) Ω -10 to 40 °C -20 to 60 °C <0.0010 %Capacity/°C <0.0010 %Capacity/°C 300% >500 @100Vdc MΩ A (mm) B (mm)
C (mm)
D (mm)
Dia. (mm)
TD1,5 TD2,5 TD5 TD7,5 TD10 TD12,5 TD15 TD20 TD25
175 185 185 200 270 270 270 350 350
70 70 70 75 90 90 90 120 120
17 25 25 25 30 30 30 50 50
16 20 26 35 36 39 43 52 52
1,5 2,5 5 7,5 10 12,5 15 20 25
110 120 120 135 170 170 170 220 220
15 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
BOLT-ON BOLT-ON • Cost effective solution for high capacity. vessel/silo weighing applications. • Robust construction. • Simple installation. • IP65. • Supplied with 4 mtrs. Cable and all mounting accessories.
Specifications:
BOSS-F
BOSS-F
Full Load Output: Zero Load Output: Excitation (Max): Accuracy: Repeatability: Terminal resistance: Deflection: Compensated Temp. Range: Operation Temp. Range: Temp. Coefficient on Zero: Temp. Coefficient on Span: Safe Overload: Insulation: Item No:
1.0 nom. mV/V @1000psi <±5.0% 10 (15)V <0.25% <0.04% 350 nom.Ω <0.5 mm -10 to 40 °C -20 to 60 °C 0.010% Capacity/°C 0.005% Capacity/°C 200% >5000@100Vdc MΩ
20.0 nom. mV/V @1000psi <±5.0% 10 (15)V <0.25% <0.04% 2100 nom.Ω <0.5 mm -10 to 40 °C -20 to 60 °C 0.010% Capacity/°C 0.010% Capacity/°C 200% >5000@100Vdc MΩ
BOLT-ON
16 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Bin Lift Cell BINLIFT CELL • Designed for extremely high fatigue stress and impact loads experienced in onbord vehicle weighing. • Approved for commercial weighing to OIML R60 2000. • Stainless steel construction. Fully welded. • Ideal for hostile environments. • High accuracy and durability. • Excellent dynamic. Specifications:
DT4650
Accuracy class: Rated output Combined error Non-repeatability: Creep (30 mins): Temp. coef. of zero: Temp. coef. of span: Safe overload: Ultimate overload: Zero balance: Input resistance: Output resistance: Insulation: Excitation (max): Env. Protection: 4-core screened cable: Item No:
0.1% 1.0 mV/V ±0,25% 0.1 %FRO 0.02%FRO 0.03%FRO 0.005 %FRO 0.002 %FRO 150 % 300 % <1 380 (±30) Ω 350 (±2) Ω <5000 M Ω 10 (15) Volts IP68 2 mtrs. Capacity A (mm)
BIN LIFT CELL 1T BIN LIFT CELL 2T BIN LIFT CELL 5T
1T 2T 5T
56 56 56
C3 0.88 mV/V In accordance with OIML Class C3
B (mm)
150% 300% <1 380 (±30) Ω 350 (±2) Ω <5000 M Ω 10 (15) Volts IP68 2 mtrs. C (mm) D (mm)
E (mm)
F (mm)
G (mm)
35,5 35,5 35,5
75 75 75
139 139 139
95 95 95
46 46 46
127 127 127
17 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Silo Mount SILOCELL • Complete silo weighing solution incorporating lift off prevention and silo expansion without compromising accuracy. • Fully welded sensor. • High tensile stainless steel type 17-4PH. • High accuracy, durability and corrosion resistance. • High resistance to off axis loads.
Specifications: Capacity: Full Load Output: Zero Load Output: Excitation (Max): Accuracy (combined error): Repeatability: Input resistance: Output resistance: Compensated Temp. Range: Operating Temp. Range: Temp. Coefficient on Zero: Temp. Coefficient on Span: Safe overload: Insulation: IP Class: Cable Length: Capacity (T) A (mm) B (mm)
0,5T, 1T, 2T, 5T, 7,5T, 10T, 15T, 20T, 30T, 50T, 75T, 100T 2.0 (±0.25%) mV/V <±2.0% 10 (15) V <0.05% <0.01% 750 (±20) Ω 700 (±2) Ω -10° to 40°C -20° to 60°C <0.005 % Capacity/°C <0.003 % Capacity/°C 150% >500 @100Vdc MΩ IP68 10 mtrs. C (mm) D (mm) E (mm) ØF No.F G (mm)
Mim. Exsp.
1-5T 2-20T 10-50T 75T 100T
94 125 175 190 230
3 mm 4 mm 6 mm 6 mm 8 mm
105 140 175 240 250
150 200 280 300 320
124 165 230 250 300
88 117 162 184 210
13 18 22 26 26
8 8 8 12 12
12.7 18 25 25 30
18 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Shear Beam SHEARBEAM • Suitable for floor scales, vehicle-test line, hopper scales and other electronic weighing devices. • Highly accurate and reliable. • Stainless steel construction. • Sealed to IP68.
Specifications: Output sensitivity (=FS): Maximum capacity (Emax): Max. Number of load cell interval: Ratio of min. LC verification interval: Combined Error: Minimum dead load: Safe overload: Ultimate overload: Zero balance: Excitation, recommended voltage: Excitation maximum: Input resistance: Output resistance: Insulation resistance: Compensated temp.: Operating temp.: Storage temp.: Item No: SHEARBEAM-xxT-z1 SHEARBEAM-xxT-z1 SHEARBEAM-xxT-z1
OIML R60 C3 2.0 ± 0.04 mV/V
OIML R60 C4 2.0 ± 0.04 mV/V
OIML R60 C5 3.0 ± 0.08 mV/V
OIML R60 C6 3.0 ± 0.08 mV/V
0.5T, 1T, 1.5T, 2T, 2.5T, 3T, 5T, 7.5T, 10T 3000 nLC 4000 nLC 5000 nLC 1000 15000 20000 ≤± 0.0230 %FS ≤± 0.0175 %FS ≤± 0.0140 %FS 0% of Emax 150% of Emax 300% of Emax <± 1.0% of FS 5 to 12 V 18 V 350 ± 3.5 Ω 350 ± 3.5 Ω ≥ 5000 (at 50VDC) MΩ -10 to 40°C -35 to 65°C -40 to 75°C Capacity (T) L x B x H (mm) ØD (mm)
0.5, 1, 1.5, 2, 2.5T 6000 nLC 20000 ≤± 0.0116 %FS
0.5, 1, 1.5, 2 2.5, 5 7.5, 10
M12 M20 M24
130 x 31.3 x 31.3 171 x 36.8 x 36.8 222 x 49.5 x 49.5
13.5 20.5 26.9
M
19 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Button Cell BUTTON • Capacities 500kN to 20kN. • Robust, durable and very compact construction. • Highly accurate and reliable. ±0.25% accuracy. • Low height. • Integral load button. • Compression applications. • Easy connection to the customers' applications. Specifications: Full load output: Zero load output: Excitation (Max): Accuracy: Repeatability: Input resistance: Output resistance: Compensated temp.: Operating temp. Range: Temp. Coefficient on zero: Temp. Coefficient on span: Safe overload: Insulation: IP class: Item No: Capacity (kN)
2.0 (±0.25%) mV/V. <±2.0%. 10 (15) V. <0.25%. <0.01%. 375 (±20) Ω. 350 (±2) Ω. -10°C to 40°C. -20°C to 70°C. <0.0015 % capacity/°C. <0.002 % capacity/°C. 150%. >500 @ 100Vdc MΩ. IP65. A (mm) B (mm) C (mm)
D (mm)
Options:
BUTTON0.5kN BUTTON1kN BUTTON2kN BUTTON5kN BUTTON10kN BUTTON20kN
15 15 15 30 30 30
4 4 4 4 4 4
Non-standard sizes available. Other ranges on request. Special mounting adaptors. Shunt calibration facility. Different temperature compensation available.
0.5 1 2 5 10 20
7 7 7 11 11 11
0.5 0.5 0.5 0.5 0.5 0.5
20 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Annular Load Cell FORCE-WASHER • Range 10kN to 200kN. • Highly accurate and reliable. • Robust, compact and low profile construction. • Suitable for metric or imperial bolts. • Compression applications. • Easy connection to the customers' applications. • Provided with 4 mtrs. cable length. Specifications:
Options:
Full load output: Zero load output: Excitation (Max): Accuracy: Repeatability: Input resistance: Output resistance: Compensated temp.: Operating temp. Range: Temp. Coefficient on zero: Temp. Coefficient on span: Safe overload: Insulation: IP class: Item No:
1.0 nom. mV/V. <±1.0%. 10 (15) V. <0.5%. <0.10%. 750 Ω. 700 Ω. -10°C to 40°C. -20°C to 60°C. <0.030 % capacity/°C. <0.0050 % capacity/°C. 150%. >500 @ 100Vdc MΩ. IP66. Capacity (kN) Bolt Size
A (mm)
B (mm)
C (mm)
FORCE-WASHER10kN FORCE-WASHER20kN FORCE-WASHER40kN FORCE-WASHER80kN FORCE-WASHER100kN FORCE-WASHER120kN FORCE-WASHER160kN FORCE-WASHER200kN
10 20 40 80 100 120 160 200
18 22 28 38 42 50 60 75
6.1 8.1 10.2 12.2 16.3 24.3 30.5 36.5
12 12 12 15 20 25 30 30
M6 M8 M10 M12 M16 M24 M30 M36
Other ranges available on request. Full range of mounting options. Non-standard sizes available.
21 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Amplifier OL3000A • For overload protection on hoist, winches in lifting or crane applications. • The load cell amplifier is used in conjunction with load cells as Static Line Tensiometers and Load Pins. • Din rail mounted.
Specifications: Accuracy: Output: Features: Weight:
<0.1% 4-20 mA Relays (n0) triggers at a user set level. 0.20 kg.
Item No: OL3000A-230 OL3000A-48 OL3000A-115 OL3000A-24 OL3000A-SUM
Output 230 VAC 48 VAC 115 VAC 24 VDC 230 VAC
Relay Output
4-20 mA 4-20 mA 4-20 mA 4-20 mA 2 x 4-20 mA
2 2 2 2 2
Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
Dimensions 54 x 90 x 61 mm 54 x 90 x 61 mm 54 x 90 x 61 mm 54 x 90 x 61 mm 54 x 90 x 61 mm
22 www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Panel Meter P1001/6 • Vetec Panel Meter Display is ideal in combination with load cells. • Clear, variable brightness display. • Provided with and without Relay output (alarms) and special output options. • Very easy to programme and use. No-menu programming. • High precision and long term reliability.
Specifications: Digits: Viewing: Input signals:
Output options:
IP Class: Materials: Case dimensions: Item No.:
6 digits. 14 mm digit height. Up to 7m away. • Load cells • 4-20mA, 0-10V, 1-5V etc. • Serial Data RS232, RS485 etc. • 2 or 4 alarms SPST relays, 2x SPDT. • 4-20mA, 0-10V or -10 to +10 analog. • RS232, RS485, Modbus, Ethernet. RTU Modbus for Tiger G2. IP65 front. 1/8 DIN format case. Black polycarbonate. W 96 x H 48 x L136 mm, (±1mm) Digits Digit height Power Supply
Analogue Output
Relay Output
P1001/6-L-R-AC-0 P1001/6-L-R-DC-0 P1001/6-L-ANI-R-AC P1001/6-L-ANI-R-DC Item No.:
6 6 6 6 Digits
14 mm 14 mm 14 mm 14 mm Digit height
95-265 VAC 11-30 VDC 95-265 VAC 11-30 VDC Power Supply
4-20 mA 4-20 mA Analogue Output
0 0 0 0 Relay Output
P1001/6-L-AL2-R-AC P1001/6-L-AL2-R-DC P1001/6-L-ANI-AL2-R-AC P1001/6-L-ANI-AL2-R-DC Item No.:
6 6 6 6 Digits
14 mm 14 mm 14 mm 14 mm Digit height
95-265 VAC 11-30 VDC 95-265 VAC 11-30 VDC Power Supply
4-20 mA 4-20 mA Analogue Output
2 2 2 2 Relay Output
4-20 mA RS485 MODBUS RTU (Tiger) MODBUS RTU (Tiger)
0 0 0 2
P1001/6-L-ANI-R-AC 6 14 mm 95-265 VAC P1001/6-L-485-R-AC 6 14 mm 95-265 VAC P1001/6-L-RTU-R-AC 6 14 mm 95-265 VAC P1001/6-L-A2-RTU-R-AC 6 14 mm 95-265 VAC * The listed examples are all with load cell input. Other displays can be provided to meet specific requirements and applications.
23 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Large Display D1002, D1004 • Vetec Large Display is ideal in combination with load cells. • Provided with and without Relay Output (alarms) and special output options. • Remote setting from ground level. • Very easy to programme and use. No-menu programming.
Specifications: Digits: Input signals:
Output options:
IP Class: Materials:
Available with 4 and 6 digits. • Load cells. • 4-20mA, 0-10V, 1-5V etc. • Serial Data RS232, RS485, 422 etc. • 2 or 4 alarms SPST relays, 2x SPDT. • 4-20mA, 0-10V or -10 to +10 analog. • RS232, RS485, Ethernet data output. IP65 for bottom glands, IP54 for top. Black polycarbonate.
Examples, all with load cell input. Item No.: Digits
Digit height
Viewing Power Supply
Relay Output
Analogue Output
D1002/4-L-R-AC-3 D1004/4-L-R-AC-3 D1004/6-L-R-AC-3 D1004/6-L-R-48VAC-3 Item No.:
4 4 6 6 Digits
57 mm 102 mm 102 mm 102 mm Digit height
25 mtrs. 50 mtrs. 50 mtrs. 50 mtrs. Viewing
95-265 VAC 95-265 VAC 95-265 VAC 48 VAC Power Supply
0 0 0 0 Relay Output
Analogue Output
D1002/4-L-AL2-R-AC-3 D1004/4-L-AL2-R-AC-3 D1004/6-L-AL2-R-AC-3 D1004/6-L-AL2-R-48-3 Item No.:
4 4 6 6 Digits
57 mm 102 mm 57 mm 102 mm Digit height
25 mtrs. 50 mtrs. 25 mtrs. 50 mtrs. Viewing
95-265 VAC 95-265 VAC 95-265 VAC 48 VAC Power Supply
2 2 2 2 Relay Output
Analogue Output
D1004/4-L-ANI-AC-3 4 102 mm 50 mtrs. 95-265 VAC 0 D1004/4-L-485-AC-3 4 102 mm 50 mtrs. 95-265 VAC 0 D1004/4-L-A2-RTU-AC-3 4 102 mm 50 mtrs. 95-265 VAC 2 D1004/6-L-A2-RTU-AC-3 6 102 mm 50 mtrs. 95-265 VAC 2 * Other displays can be provided to meet specific requirements and other applications.
4-20Ma RS485 MODBUS RTU MODBUS RTU
24 Address Lucernemarken 18 A DK-5260 Odense S
Bank Account DKK 8117-4522421 EUR 8117-9653680
SWIFT code NYKBDKKK
Bank Nykredit Bank
IBAN no. DKK DK7681170004522421 EUR DK1981170009653680
VAT no. 27414621
www.vetec.dk Telephone +45 6590 5802 Mail post@vetec.dk
Remote Controls TIGER G2 • Tiger G2 has been developed for radio controlled lifting applications, e.g. EOT cranes, container cranes and more. • Transmitters with display show load indication when combined with our complete load cell systems. • For maximum load control and safety.
Specifications: Channels: Approvals:
69. The stop function and two relays in the receivers are approved according to SIL3 IEC 61508 standard and PLe.
IP Class:
Item No.:
Transmitters and receivers are approved according to IP65. TG-T9 transmitters are approved according to IP66. All receivers IP66. Frequency Channels
Buttons
TG-T9-2 TG-T11-4 TG-T12-20 TG-T12-21 Item No.:
433 MHz, 915 MHz and 2,4 GHZ 433 MHz, 915 MHz and 2,4 GHZ 433 MHz and 915 MHz 433 MHz and 915 MHz Frequency
69 69 69 69 Channels
6 10 Joystick Joystick Relays
TG-R4-1 TG-R4-6 TG-R9-11
433 MHz, 915 MHz and 2,4 GHZ 433 MHz, 915 MHz and 2,4 GHZ 433 MHz and 915 MHz