MBVC Variable-Speed, ComfortNet™Compatible Modular Blowers Cooling Capacity: 18,000 - 60,000 BTU/h

Standard Features

• Compatible with the ComfortNet Communication System family of products • Variable-speed ECM blower motor • Auto configuration of the airflow and tonnage in communicating mode • CFM indicator • Maximum four low-voltage wires required for operation in communicating mode • Built-in dehumidify feature • Diagnostic indicator lights • Storage of six prior fault codes • Programmable heat strip settings • Color-coded terminal strip for noncommunicating set-up • Cooling and heat pump applications • AHRI Certified • ETL Listed

Cabinet Features

• Painted, galvanized steel cabinet • Blower section usable as an electric furnace • Foil-faced insulation is glued in place and covers the entire blower case, reducing sound and cabinet condensation • Bottom flanges formed inward for additional strength, and to provide mounting surface for cased-coil section

* Complete warranty details available from your local dealer or at www. goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec.

SS-GMBVC

www.goodmanmfg.com

11/09


Product Specifications

Nomenclature MB 1,2

VC 3,4

12 5,6

00 7,8

A 9

Design Series MB Modular Blower

1 11

Electrical 1 208-230/60/1

Motor Speed V Variable Speed C ComfortNet™ Compatible

Revisions A First Series Circuit Breaker A No Circuit Breaker B Circuit Breaker

Airflow Delivered 08 800 CFM 12 1200 CFM 16 1600 CFM 20 2000 CFM

2

A 10

Factory-installed Electric Heat 00 No Heat

www.goodmanmfg.com

SS-GMBVC


Product Specifications

Specifications Blower Dimensions Motor HP Diameter Width

CFM @ 0.3” ESP (High to Low)

VoltagePhase

MCA*

MOP*

MBVC1200AA-1

1,200 to 600

208/230-1

4.3

15

10”

8”

½

73

MBVC1600AA-1

1,600 to 1,000

208/230-1

6.3

15

10”

8”

¾

83

MBVC2000AA-1

2,000 to 1,200

208/230-1

5.8

15

11”

10”

¾

95

Model

Ship Weight (lbs)

* Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed. Refer to unit nameplate for these specifications with approved accessory heaters installed.

Heat Kit Selection MBVC1200 AA-1A*

MBVC1600 AA-1A*

MBVC2000 AA-1A*

HKR-03*

X

X

X

HKR-05*/-05C*

X

X

X

HKR-06*

X

X

X

HKR-08*/-08C*

X

X

X

HKR-10*/-10C*

X

X

X

HKR-15C*

X

X

X

HKR-20C*

X

X Allowable combinations * Indicates revision level that may or may not be designated C Indicates Circuit Breaker option

Single Point Kit ** Model SPW-01

HKR-15C

HKR-20C

HKR-21C

X

X

X

** Must be installed along with any of the above compatible heat kits. This kit will fit any MBVC blower as long as a compatible heat kit is installed in the unit.

SS-GMBVC

www.goodmanmfg.com

3


Product Specifications Cooling / HP Airflow S1

S2

Speed Tap

MBVC1200 Airflow (SCFM)

MBVC1600 Airflow (SCFM)

MBVC2000 Airflow (SCFM)

off on off on

off off on on

A B C D

600 800 1000 1200

1000 1200 1400 1600

1200 1600 1800 2000

Cooling / HP / Aux Trim S3 S4 Trim Value off off 0

S5 off

Cooling Profile S6 off

A

on off on

on off on

off on on

B C D

off on on

10% -10% 0

Heater Kit kW Airflow S9

S10

S11

Heater KW

MBVC1200 Airflow (SCFM)

MBVC1600 Airflow (SCFM)

MBVC2000 Airflow (SCFM)

off off off off on on on on

off off on on off off on on

off on off on off on off on

21 20 15 10 8 6 5 3

NA NA 1400 1000 740 635 600 600

NA NA 1500 1000 1000 800 800 800

NA 2000 1500 1200 1000 800 800 800

MBVC Blower Performance Data — Dipswitch Summary Dipswitch # S1 - S2* S3 - S4* S5 - S6* S7* S8 S9 - S11

Function Cooling / HP Airflow A/B/C/D Cooling / HP / Aux Trim (-10%, 0, +10%) Cooling Profile A,B,C,D Dehum (on/off) Unused Heater Kit Kw

Default Setting Airflow D No Trim Profile 1 Off On Off/Off/Off

* Valid only if the system is wired in legacy mode. If system is wired in the 4-wire communicating mode, these functions are selected via the user menu in the CTK01AA T-STAT.

4

www.goodmanmfg.com

SS-GMBVC


Product Specifications

Dimensions Side and Front Views D 3 1/4

5 C1/8

(3) KNOCKOUTS 1.125 1.375 1.750 .875 KNOCKOUT (2 PLACES)

H

5 6 1/2

20"

W

Dimensions

Model

Width

Depth

Height

17½”

21”

26”

MBVC1600AA-1

21”

21”

30”

MBVC2000AA-1

24½”

21”

30”

MBVC1200AA-1

Top View 11.029 11”

13 88.840 /16” 3 10.159 10 /16”

13.178

11¼” 11.209

11.209 11¼” 20.021 201/16”

16.500 16 ½”

SMALL 17½”

SS-GMBVC

23.464 23 ½”

21” MEDIUM

www.goodmanmfg.com

24½” LARGE

5


PWIRING roduct Specifications DIAGRAMS

THERMOSTATS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

Wiring Diagrams

R

Typical Two-Stage Cool, Two-Stage Heat Thermostat Y2

C G

1

2

R C G

Y1 W1 W2

W1 W2 Y1

Y2

Y1

Y2

O

DEHUM

Modular Blower Integrated Control Module

* C

R

NEU HOT

Remote Condensing Unit (Two-Stage AC)

Dehumidistat [Optional]

Typical Two-Stage Cooling with Two-Stage Heating

O

R C

Y1

G EMR

1

2

R C G

Typical Two-Stage Cool, Two-Stage Heat Heat Pump Thermostat

Y2 W2

W1 W2 Y1

Y2

O

W1

Y2

O

DEHUM

Modular Blower Integrated Control Module

* C

R

Y1

Remote Condensing Unit (Two-Stage HP)

NEU HOT

Dehumidistat [Optional]

Typcial Two-Stage Heat Pump Heating and Auxiliary/Emergency Heating

Typical Two Stage Heat Pump heating and Auxiliary/Emergency Heating Wiring is subject to change. Always Wiring is subject to refer to the wiring diagram or the unit for the most up-to-date wiring.

6

change. Always refer theDisconnect wiring diagram the servicing unit for ortheinstalling most up-to-date wiring. High to Voltage: all poweron before this unit. Multiple power Warning sources may be present. Failure to do so may cause property damage, personal injury, or death.

www.goodmanmfg.com

7

SS-GMBVC


Product Specifications

WIRING DIAGRAMS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

Wiring Diagrams (cont.)

FL

PU BL

BK

3

WH BK

RD

5

M2

M1

R

6

RD

BK

8

PU

M2

BL M3

RD

M1

M4

BL

M2

R1

5

M4

M2

RD

R2

BR

BK

BK

BK RD

RD

WH

6

RD

PLM

BL BK

3

BL

1

4 5

M1

YL

RD

M4

M5

M7

M6

M8

R1

6

3

BL

M3

M2

2

PU

BK R D

RD

R2

BK

BK

RD

BL

4

BR

5 6

WH

7 7

BK RD

YL

7

8

BK

8

9

RD

YL

9

BL BK

8

RD

9 L1

YL

H TR4 TL

1 2

YL

BK M1

4

M3

H TR1 TL

H TR3 TL

FL

P LM BK

RD

YL

3

WH

7

BK

2

PU BL

BK

RD

HT R3 TL

1

RD

4

M1

R

BK

BK

2

HT R2 TL

FL

PLM

1

RD

FL

9

L2 L1

ONE (1) ELEMENT ROWS

L2

L1

TWO (2) ELEMENT ROWS

L2

L1

L2

THREE (3) ELEMENT ROWS

L1

L2

L1

L2

FOUR (4) ELEMENT ROWS

NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE. MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROW S INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED.

6

6 5 4

5 4 7 8 9

SEE NOTE 7

WH BL

GN DISCONNECT

BL

BK BR

BL

RD

TR

TH

4 CIRCUIT HEATER CONNECTOR

FUSE

CFM LED

24 V 3A

SEE NOTE 5

ELEC HEAT AF

DELAY

DEHUM UNUSED

1

O Y2

2

DIP SWITCHES

W2

LEARN

W1

BIAS TERM

STATUS LED

BIAS

4

G C

RX LED

R

SEE NOTE 6

2

1 TWO-STAGE INTEGRATED CONTROL MODULE

CIRCULATOR BLOWER GND

3 2 1

ECM MOTOR HARNESS

TH 24 VAC

W1 (1)

W1

HEAT SEQUENCER R1

W2 (2)

W2 Y1 Y2

L2 40 VA TRANSFORMER

HEAT SEQUENCER R2

+VDC (1) TO MICRO

G

RX (2)

INDOOR AIR CIRCULATOR BLWR

TX (3)

O

4

BL GY BK RD

24V THERMOSTAT CONNECTIONS

Y1

3

FUSE 3 A R

GND

208/230 VAC

L1

DEHUM 24 V THERMOSTAT CONNECTIONS

ADJUST

DIAGNOSTIC LED

COOL

R D

INDOOR AIR CIRCULATOR BLWR

COM

-

B K

7 8 9

COM

BK

Warning

1

24 VAC

1 2 3 4 5

GN BK

DEHUM C

NOTES:

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE BLOWER MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY. 4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (N THERMOSTAT INPUTS). 6. BIAS AND TERM DIPSWITCHES MUST BE IN "ON" POSITION. RED STATUS LED PROVIDES NETWORK STATUS. GREEN RX LED INDICATES NETWORK TRAFFIC. USE LEARN BUTTON TO RESET NETWORK.

TR COM

RD

1. PLACE RED WIRE ON TRANSFORMER TERMINAL 2 FOR 208 VAC OPERATION. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

GND (4)

1

L2

GND

GND

RD

208 VAC

1

3

230 VAC RD

3

3

RD

2

2

4

2

L1

40 VA TRANSFORMER, SEE NOTE 1

PL1 PL2

INTEGRATED CONTROL MODULE

GY GRAY RD RED YL YELLOW OR ORANGE VT VIOLET GN GREEN

GND

LOW VOLTAGE (24V)

COLOR CODES: PK PINK BR BROWN WH WHITE BL BLUE

LOW VOLTAGE FIELD HI VOLTAGE (230V) HI VOLTAGE FIELD JUNCTION TERMINAL INTERNAL TO INTEGRATED CONTROL

BK BLACK

BK

RD

BK

EQUIPMENT GND

Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring.

HTR1 TL

H TR2 TL

FL HT R1 TL

FL

PLM

BK

FL

HTR2 TL

FL

HTR1 TL

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.

FL

FL

FIELD GND FIELD SPLICE RESISTER

7. DISCARD CONNECTOR PL1 WHEN INSTALLING OPTIONAL HEAT KIT.

OVERCURRENT PROT. DEVICE PLUG CONNECTION

0140A00039 REV. A

8

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

SS-GMBVC

www.goodmanmfg.com

7


Product Specifications

Notes

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2010 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.

8

www.goodmanmfg.com

SS-GMBVC


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.