Specifications

5CSB2-04A

5.2 Outdoor unit Outdoor Unit Nominal Capacity

Cooling Heating

Nominal Input

Cooling Heating

kW Btu/h kW Btu/h kW kW

LBUC306GSS0

LBUC366GSS0

LBUC368GSS0

8.79 30,000 3.3 15 1/220~240/50 3 x 5.5

10.6 36,000 4.0 18.5 125/1/220~240/50 3 x 5.5

10.6 36,000 4 7.2 45/3/380~415/50 5 x 2.5

Testing Combination Running Current(Rating) Cooling A Heating A Starting Current Cooling/Heating A Power Supply Ø / V / Hz Power Supply Cable(Outdoor) No. x mm2 Power and Transmission Cable 4 x 0.75(Including Earth) 4 x 0.75(Including Earth) 4 x 0.75(Including Earth) No. x mm2 (Outdoor to Indoor or Outdoor to BD) 2 Power and Transmission Cable(BD to Indoor) No. x mm 870 x 808 x 320(34.3 x 31.8 x 12.6) 870 x 808 x 320(34.3 x 31.8 x 12.6) 870 x 808 x 320(34.3 x 31.8 x 12.6) Dimensions WxHxD mm(inch) 72(158.7) 72(158.7) 73(160.9) Net Weight kg(lbs) 1 1 1 Max. Number of Connectable Indoor Units Rotary(Tropical) Reciprocating(Tropical) Reciprocating(Tropical) Compressor (#1) Type 1 x NHT52VBAT 1 x CR47KQ-PFZ-290JB 1 x CR47KQ-TFD-290JB Qty x Model Single phase induction 1 Phase PSC 3 Phase PSC Motor type 1,300 1,331 1,331 Oil charge volume cc DIAMOND MS 56 3GS 3GS Oil Type Compressor (#2) Type Qty x Model Motor type Oil charge volume cc Oil type Compressor (#3) Type Qty x Model Motor type Oil charge volume cc Oil type 2,100(74.1) 1,700(60.0) 1,840(64.9) Refrigerant Cycle A Charge (at 7.5m) g(oz) Cycle B Charge (at 7.5m) g(oz) 45(1.59) 60(2.12) 40(1.41) Cycle A Additional Charge g(oz)/m Cycle B Additional Charge g(oz)/m R22 R22 R22 Type Capillary tube Capillary tube Capillary tube Control (2R x 30C x 17) x 1 (2 x 36 x 18) x 1 (2R x 36C x 18) x 1 Heat Exchanger (Rows x Column x FPI) x No. Defrosting Method 6/370 10/370 10/370 Fan Capacitor µF/Vac Direct Drive Direct Drive DIRECT Drive Side Side Side Discharge Direction(Side/Top) 49(1730) x 1 58(2048) x 1 58(2048) x 1 Air Flow Rate x No. of Fan CMM(cfm) 56 58 58 Sound Level(H/L) Sound Pressure dB(A)+3 6.35(1/4) 6.35(1/4) 6.35(1/4) Piping Connections Liquid(Cycle A) mm(inch) 15.88(5/8) 15.88(5/8) 15.88(5/8) Gas(Cycle A) mm(inch) Liquid(Cycle B) mm(inch) Gas(Cycle B) mm(inch) High Pressure Gas mm(inch) 50 50 50 Max. Interunit Total Piping m 7.5 7.5 7.5 Piping Length Main Piping m Total Branch Piping m Each Branch Piping m 30 30 30 Max. Elevation Outdoor Unit~Indoor Unit m Difference Indoor Unit~Indoor Unit m Note: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB - Outdoor Temperature 35°C(95°F) DB/24°C(75.2°F) WB Heating: - Indoor Temperature 20°C(68°F) DB/15°C(59°F) WB - Outdoor Temperature 7°C(44.6°F) DB/6°C(42.8°F) WB Piping Length - Interconnecting Piping Length 7.5m - Level Difference of Zero 2. Wiring cable size must comply with the applicable local and national code. 3. The specification may be subject to change without prior notice for purpose of improvement.

22

Ceiling Concealed Duct

50Hz, R22


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.