AP-MIY-09

Page 1

All Product Catalogue R410A Inverter Wall Mounted Y-Series INDOOR UNIT

M5WMY010JR

M5WMY015JR

OUTDOOR UNIT

M5LCY010DR

M5LCY015DR

Btu/h

8,530

11,950

W

2,500

3,500

Btu/h

10,240

12,970

W

3,000

3,800

EER

W/W

3.41

3.30

COP

W/W

3.62

3.61

HEATPUMP MODEL

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

POWER SOURCE

INDOOR UNIT

AIR FLOW

158 / 335

l/s / cfm

132 / 279

138 / 293

l/s / cfm

105 / 222

113 / 240

dBA

39 / 25

41 / 27

HEIGHT

mm

288

288

WIDTH

mm

800

800

DEPTH

mm

204

204

dBA

46

49

HEIGHT

mm

550

550

WIDTH

mm

765

765

DEPTH

mm

285

SIZE

285 FLARE VALVE

TYPE PIPE CONNECTION

163 / 346

MEDIUM

SOUND PRESSURE LEVEL UNIT DIMENSION

l/s / cfm

LOW SOUND PRESSURE LEVEL (MAX/MIN)

UNIT DIMENSION

OUTDOOR UNIT

220-240/1/50

V/Ph/Hz HIGH

LIQUID

mm

6.35

6.35

GAS

mm

9.52

12.7

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT. 5) SPECIFICATIONS ARE TENTATIVE VALUES AT THE TIME OF PRINTING. CONSULT YOUR DEALER FOR LATEST INFORMATION.

Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.mcquay.com.

©2009 McQuay International

+1 (800) 432-1342

www.mcquay.com

A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration.

AP-MIY-09


HIGHER ENERGY SAVINGS

STYLISH FLAT-PANEL

Higher performance at lower power consumption. • Makes air-conditioners more economically sensible to operate when compared to conventional fixed-speed units. • By using intelligent controls, compressor running speed is matched with air-conditioning load. This achieves significant savings in energy consumption.

Ideal blend of style and function. • The front panel is designed for contemporary style without compromising on function. • Air intake area is designed to ensure smooth air flow profile for better sound quality and optimized air flow volume.

DC INVERTER TECHNOLOGY

R410A REFRIGERANT WITH ZERO-ODP

UNSURPASSED LEVEL OF COMFORT

LONG-TERM RELIABILITY

Reduced wear and tear. • Compared to conventional fixed-speed units, start-stop cycle is lessened. Therefore, compressor lifespan is extended naturally.

25 25

LOWER SOUND LEVEL

More quiet room environment. • With up to five selectable fan speeds, users are given more dBA choices. By selecting Quiet mode, the sound pressure level is reduced down to an unobtrusive 25 dBA. • To quickly cool down the room, turbo mode can be selected for maximum cooling power and highest airflow.

COMPACT G17 HANDSET

Full-featured and easy-to-use. • Prominent temperature display. • Real-time clock display. • Easily accessible buttons for On/Off, Temperature Setting, Fan Speed and Mode control. • Dedicated buttons or Silent and Turbo functions.

Fast Cooling

UNSURPASSED LEVELS OF COMFORT

Set Temperature

Narrow temperature band at ±0.5 deg C. • Working in tandem, the inverter compressor and electronic expansion valve ensures smooth refrigerant flow. • Room temperature variation is never more than 0.5 deg Celsius to ensure optimum comfort for room occupants.

Conventional Air Conditioner

• High starting current • Frequent on/off cycle

Soft-start feature. • High current draw during startup is avoided due to the smooth ramp-up profile of inverter compressor.

Inverter Air Conditioner

• Low starting current • Smooth operation

*R410A Characteristics

1

Time

Conventional System

Refrigerant

ODP*1

GWP*2

R22

0.05

1,700

R410A

0

1,950

*1: Ozone Depletion Potential

Efficiency

Flammability

Toxicity

High

Nonflammable

Low

Providing right conditions for restful sleep. • Once activated, sleep mode ensures a comfortable environment for restful sleep. • Depending on the mode, set temperature is increased / decreased gradually according to normal sleeping temperature patterns.

ling

Sl 0 1/ eep Set On 2 1 2

-1˚C ng

ati

He

-2˚C

Heating mode*

-3˚C

Coo

0 1/ 2 Slee 1 p Se tO

Cooling mode

+1˚C

+0.5˚C

+0.5˚C

n

2

* Heat pump models only Running Current

LOW STARTING CURRENT

The Ozone Depletion Potential (O.D.P.) for R410A is zero. However, it is a green house gas whose Global Warming Potential (G.W.P.) is similar to the high G.W.P. for R22. McQuay is working to develop next generation refrigerants and the products that will use them.

Inverter System

SLEEP FUNCTION

rs

Time

Room Temperature

Hou

Set Temperature

Temperature

Precise & Stable Temperature Control

s

Room comfort level is constantly maintained even when the number of people in the room increases or decreases.

Room Temperature

Temperature

Rapid response time. After quickly reaching Set Temperature, the inverter system constantly adjusts and fine-tunes the cooling/heating capacity to prevent undesired temperature swings.

Ho ur

FLEXIBLE PERFORMANCE

PERSONALIZED FUNCTION

One-button access to your favorite conditions. Allows users to store 2 sets of individual settings including operating mode, temperature, fan speed, and ON/OFF timer according to your specific needs. Each setting can be restored quite conveniently at a later time.

Hours of operation

*2: Global Warming Potential (IPCC2001)

2


All Product Catalogue R410A DC Inverter Wall Mounted Y-Series INDOOR UNIT

M5WMY10JR

M5WMY15JR

OUTDOOR UNIT

M5LCY10DR

M5LCY15DR

Btu/h

8,530

11,950

W

2,500

3,500

Btu/h

10,240

12,970

W

3,000

3,800

EER

W/W

3.41

3.30

COP

W/W

3.62

3.61

HEAT PUMP MODEL

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

POWER SOURCE

INDOOR UNIT

AIR FLOW

158 / 335

l/s / cfm

132 / 279

138 / 293

l/s / cfm

105 / 222

113 / 240

dBA

39 / 25

41 / 27

HEIGHT

mm

288

288

WIDTH

mm

800

800

DEPTH

mm

204

204

dBA

46

49

HEIGHT

mm

550

550

WIDTH

mm

765

765

DEPTH

mm

285

SIZE

285 FLARE VALVE

TYPE PIPE CONNECTION

163 / 346

MEDIUM

SOUND PRESSURE LEVEL UNIT DIMENSION

l/s / cfm

LOW SOUND PRESSURE LEVEL (MAX/MIN)

UNIT DIMENSION

OUTDOOR UNIT

220-240/1/50

V/Ph/Hz HIGH

LIQUID

mm

6.35

6.35

GAS

mm

9.52

12.7

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT. 5) SPECIFICATIONS ARE TENTATIVE VALUES AT THE TIME OF PRINTING. CONSULT YOUR DEALER FOR LATEST INFORMATION.

Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.mcquay.com.

©2009 McQuay International

+1 (800) 432-1342

www.mcquay.com

A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration.

AP-MIY-09