MYSON Design Radiators Brochure and Technical Guide

Page 1

MYSON

Design Radiators Brochure & Technical Guide

heatingthroughinnovation.


02

Contents

COLUMN.

DÉCOR.


Contents

NEW

NEW

Introduction

04

COLUMN Range

06

Technical Information

08

Sizes and Outputs

10

General Specifications

12

Colour Board

13

Electric COLUMN

22

DÉCOR Range

14

Technical Information

16

Sizes and Outputs

18

General Specifications

20

Colour Board

21

Electric DÉCOR

22

03


04

I n t ro d u c t i o n

Join the design

revolution!


I n t ro d u c t i o n

In recent years, there has been a revolution in attitude towards radiators. Previously perceived as a purely functional item that ideally needs to disappear into the background and not be seen at all, a radiator is now increasingly being viewed as a stylish feature and upfront, focal point within a room. The MYSON COLUMN and DÉCOR ranges of design radiators have been at the very forefront of this trend since its beginning. They have played a leading role in helping to turn the humble radiator into a treasured decorative addition to a home. COLUMN and DÉCOR radiators are produced in both hydronic and electric versions and with an unbeatable choice of heights, lengths and colours available, there is a COLUMN or DÉCOR radiator to suit the decorative needs of every room. Take a little time to browse the many options available in this brochure and discover which ones are right for you. By installing a COLUMN or DÉCOR radiator into your home, you too can join the design revolution!

05


06

COLUMN Range

Now Available in Electric please see page 22 for more information

COLUMN Vertical.


COLUMN Range

COLUMN Range Looking to add an individual, stylish feature to your rooms? The MYSON COLUMN range has turned the humble radiator into a focal point and created a selection of new interior design possibilities for you. The proportions, scale and detailing of the MYSON COLUMN combine to give a symmetry and elegance that feels just right. Each unit is manufactured using the very latest, unique laser welding technology to create a radiator range of the highest quality, with a paint finish that is second to none. There is a colour, size and column configuration to suit every situation. COLUMN radiators are ideal for a variety of domestic or commercial uses.

COLUMN Bench Seat.

COLUMN Horizontal.

07


08

C O L U M N Te c h n i c a l I n f o r m a t i o n

Fixing Brackets (supplied with every radiator) - Wall Brackets 50

30

16

20

10.5

6

14

5 6.5

8.5

18

59

6

83

20.5 14

4.5 34.5 3.6 17

15

12

20

Radiator Brackets A (see table below)

19 32.5

62

Ensure tight fit here

11

13

Radiator Bracket 25 Angle Wall Bracket

11.5

20

11

30

Wall & Bracket

Wall Bracket & Radiator Bracket

Wall & Radiator

20mm

11mm

30mm

11mm

A = Distance between Wall & Centre

2 column

3 column

4 column

31mm

62.5

81.5

100.5

41mm

72.5

91.5

110.5

insert

Connections All MYSON COLUMN radiators are fitted with 4 x 1/2 inch BSP connections.

blue. It is important that the water inlet is connected to the tapping identified in red.

Radiators include plug and vent.

N.B. The radiator is suitable for the use of BBOE (Bottom Bottom Opposite End), TBSE (Top Bottom Same End) and TBOE (Top Bottom Opposite End) connections. TTOE (Top Top Opposite End) connections cannot be used.

Radiators are manufactured with an internal baffle. The tapping with the baffle is identified with a red plastic cap, all others being


C O L U M N Te c h n i c a l I n f o r m a t i o n

Fixing Brackets - Clamped Floor Bracket FK 8

10

Complete system for free-standing radiators, from 2-6 column up to 1000mm height. Painted to RAL 9016.

30

Comprises;

26 20

40

180-300mm

120

26

- 3mm thick base-plate fixing for either finished or unfinished floor

60 100

Clamped Floor Bracket FK

Order Code

Dimensions of base-plate for Clamped Floor Bracket FK

For 2-6 Column Rads.

FK1021

Base-Plate Cover

COVERFK

(

= base-plate cover) For use with 2-6 column radiators

Two-part cover for base-plate in white plastic 106 x 128mm

Floor Bracket SK Complete system for free-standing radiators, from 2-6 column up to 1000mm height. Painted to RAL 9016. Comprises; Two-part cover for base-plate in white plastic 110 x 135mm

104

75

8

91

116

Dimensions of base-plate for Floor Bracket SK

Operating Pressures Every MYSON COLUMN radiator is tested to a pressure of 13 bar (188.5 psi) and is suitable for a working pressure of up to 10 bar (145 psi).

- 3mm thick base-plate for fixing to either finished or unfinished floor - upright support 35 x 10 x 1.5mm, fixing set with adjustable bracket, security fixing, anti-vibration insert - adjustable bottom support with spacer and security fixing, anti-vibration insert, white plastic end stop for top of upright. Height of Upright

Height of Radiator

Order Code

460

300

SK20046

610

450

SK20061

760

600

SK20076

910

750

SK20091

Base-Plate Cover

COVERSK

09


10

COLUMN Sizes & Outputs

63 mm

101 mm

139 mm

2 COLUMN

3 COLUMN

4 COLUMN

2 COLUMN Length (mm - inches)

No. of Sections

Output (watts)

Output (Btu/h)

Order Code

Height 450 mm

600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72

12 16 20 24 28 36

435 580 725 870 1015 1305

1485 1980 2474 2969 3464 4454

12 SEC 2045 16 SEC 2045 20 SEC 2045 24 SEC 2045 28 SEC 2045 36 SEC 2045

Height 600 mm

600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55

12 16 20 24 28

564 752 940 1128 1317

1925 2567 3209 3850 4492

12 SEC 2060 16 SEC 2060 20 SEC 2060 24 SEC 2060 28 SEC 2060

300 - 12 400 - 16 500 - 20 600 - 24 750 - 30

6 8 10 12 15

881 1175 1468 1762 2202

3006 4008 5010 6012 7515

6 SEC 2200 8 SEC 2200 10 SEC 2200 12 SEC 2200 15 SEC 2200

Length (mm - inches)

No. of Sections

Output (watts)

Output (Btu/h)

Order Code

Height 300 mm

800 - 32 1000 - 40 1400 - 55 1800 - 71

16 20 28 36

566 708 991 1274

1933 2416 3382 4348

16 SEC 3030 20 SEC 3030 28 SEC 3030 36 SEC 3030

Height 450 mm

600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72

12 16 20 24 28 36

606 808 1010 1212 1414 1818

2068 2757 3446 4135 4825 6203

12 SEC 3045 16 SEC 3045 20 SEC 3045 24 SEC 3045 28 SEC 3045 36 SEC 3045

Height 600 mm

600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55

12 16 20 24 28

781 1042 1302 1562 1823

2665 3554 4442 5331 6219

12 SEC 3060 16 SEC 3060 20 SEC 3060 24 SEC 3060 28 SEC 3060

Height 750 mm

600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55

12 16 20 24 28

935 1270 1588 1906 2223

3251 4335 5418 6502 7586

12 SEC 3075 16 SEC 3075 20 SEC 3075 24 SEC 3075 28 SEC 3075

Length (mm - inches)

No. of Sections

Output (watts)

Output (Btu/h)

Order Code

Height 600 mm

600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55

12 16 20 24 28

997 1330 1662 1994 2327

3402 4537 5671 6805 7939

12 SEC 4060 16 SEC 4060 20 SEC 4060 24 SEC 4060 28 SEC 4060

Height 750 mm

600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55

12 16 20 24 28

1214 1619 2024 2429 2834

4144 5525 6906 8287 9668

12 SEC 4075 16 SEC 4075 20 SEC 4075 24 SEC 4075 28 SEC 4075

Height 2000 mm

3 COLUMN

4 COLUMN


COLUMN Sizes & Outputs

Architecture Range - Bench Radiator Length inc. seat (mm - inches)

Height inc. seat (mm - inches)

Depth inc. seat (mm - inches)

Output (watts)

Output (Btu/h)

Order Code

1850 - 73 1850 - 73 2150 - 85 2150 - 85 2350 - 93 2350 - 93

472 - 19 522 - 21 472 - 19 522 - 21 472 - 19 522 - 21

365 - 14 365 - 14 365 - 14 365 - 14 365 - 14 365 - 14

1489 1738 1816 2119 2053 2396

5080 5930 6196 7230 7005 8175

23 SEC 056150 23 SEC 066150 23 SEC 056180 23 SEC 066180 23 SEC 056200 23 SEC 066200

D

The Bench Radiator is H

sold complete, but can be sold seperately if required.

Special order only.

L

Accessories Micro Fibre Cleaning Brush

Towel Rail

Decorative Foot

Product Code: COLUMNBRUSH2

Clip-on rail to fit all

Product Code: COLDECFOOT

radiators up to 1m long (20 sections) Product Code: 12SECRAIL 16SECRAIL 20SECRAIL

Fixing Brackets

Floor Brackets

Product Code: FK1021

Product Code: SK20046

Product Code: COVERFK

Product Code: SK20061 Product Code: SK20076 Product Code: SK20091 Product Code: COVERSK

11


12

COLUMN General Specifications

General Specifications Approval and Certification All

MYSON

The installation work must be carried out in accordance with COLUMN

radiators

are

manufactured and tested to EN 442.

recognised good practice, and precautions taken to avoid contamination which could lead to corrosion. If a corrosion inhibitor or other water treatment is to be used, the

All MYSON hydronic COLUMN radiators

Manufacturer’s Instructions must be strictly followed.

carry a 10 year guarantee from date of installation against defects caused by faulty materials or

All systems must be designed with suitable pipe sizing (15mm or

manufacture.

22mm minimum depending on the length of run) and with a pump or adequate pump head. Failure to do this may lead to

2

2

2

All MYSON sealed electric COLUMN radiators

trapped air and cold spots because of insufficient pressure and

carry a 2 year guarantee from date of installation

water flow will not drive the air from the radiator. The taller and

against defects caused by faulty materials or

more tubes a radiator has, the more likely this is to happen.

manufacture. The recommendations of BS 7593, Code of Practice for treatment of water in domestic central heating systems, should be observed.

Paint Finish Every MYSON COLUMN radiator undergoes a multi-stage pre-treatment process followed by an epoxy polyester primer

Safety Precautions

coating. A stoved epoxy polyester powder coat in white (RAL

Radiators are hot when in use, and as such, present a risk of burns

9016) is applied to all front and rear surfaces allowing the

to users on prolonged contact. The temperature of a radiator is

MYSON COLUMN to be fitted without further painting. Other

dependent on the temperature of the system water, as set by the

colours are available, please refer to page 13.

system installer or user. Installers and users should ensure that those who may come into close proximity to hot radiators are aware

Manufacture

of the risk of burns. Installers and users should take all necessary

MYSON COLUMN radiators are manufactured using a unique

steps to minimise the risks of burns. If the risk is significant,

laser welding process that virtually eliminates the visible welding

consideration should be given to installing low surface temperature

points associated with the traditional methods of manufacturing

radiators, or to placing guards in front of the radiators.

this type of radiator. The clean finish significantly enhances the aesthetic qualities of the radiator.

Tube Details Precision, D-profile steel tube is used for all outside surfaces

Fixings

which ensures high outputs and soft, rounded edges for

For the correct installation of radiators it is essential that the fixing

maximum safety.

of the radiator is carried out in such a way that it is suitable for intended use AND predictable misuse. A number of elements need

Heat Output

to be taken into consideration including the fixing method used to

The heat outputs for all MYSON COLUMN radiators can be

secure the radiator to the wall, the type and condition of the wall

found on pages 10 and 11. The tabulated figures are quoted in

itself, and any additional potential forces or weights that may

accordance with EN 442 for a mean water to air temperature of

happen to be applied to the radiator, prior to finalising installation.

50oC. When the difference is not 50oC, the output should be multiplied by the appropriate factor from within the table below:

Application MYSON COLUMN radiators are for use on two pipe, pumped, Centigrade

Factor

Fahrenheit

with a maximum working temperature of 120 C. The system

40°C

0.75

72°F

should be designed in accordance with BS 5449 or BS 6880

45°C

0.87

81°F

50°C

1.00

90°F

55°C

1.13

99°F

60°C

1.27

108°F

65°C

1.41

117°F

70°C

1.55

126°F

indirect, domestic and commercial central heating installations, o

as appropriate, with particular care taken to avoid air entry or water discharge. We do not recommend the use of single feed indirect cylinders, as the possibility of aeration due to water interchange may lead to corrosion.


C O L U M N C o l o u r B o a rd

Colour Board (Hydronic Models Only)

White/Ref. 1S Ral 9016

C re a m / Ral 9001

A e g e a n G re e n / T20

P e rg a m o n / T14

L i g h t G re y / Ral 7035

Bahama Beige/ T10

Manhattan/ T11

Ye l l o w / Ral 1023

M u s t a rd / Ral 1003

Calypso/ T27

Dove/ Ral 5014

Violet/ Ral 4008

Blue/ Ral 5002

G a rd e n G re e n / Ral 6010

M o s s G re e n / Ral 6005

Ruby Red/ Ral 3003

Wine/ Ral 4004

B ro w n / Ral 8007

Chocolate/ Ral 8017

Black/ Ral 9004

IMPORTANT We can match any colour - please supply RAL reference. Due to print restrictions, exact colour match of swatches is not possible. However, every effort has been made to ensure as much accuracy as possible.

13


14

DÉCOR Range

Now Available in Electric please see page 22 for more information

V 10.


DÉCOR Range

DÉCOR Range The MYSON DÉCOR range has played a leading role in the world of interior design over the last decade. It treats radiators as decorative items as well as heating devices. With four distinctive flat tube styles to choose from you can find a model to enhance the look of any interior. We think you’ll agree that the MYSON DÉCOR range offers some stunning alternatives to mainstream radiators. The style, quality of construction and paint finish are of the highest order, so you can feel confident using MYSON DÉCOR in the most prestigious environments.

TS4.

15


16

D É C O R Te c h n i c a l I n f o r m a t i o n

DÉCOR V10 & V20 70

23 52

5

Fixing brackets

H

Fixing brackets

Connection Dimensions (V10 & V20)

33 70

Connection Dimensions

V10

V20

Wall Bracket Positioning

H

5

L

Plug

Vent

c H 110

8.2 8.2

Wall Bracket Dimensions

Water Connection

a

100 min

Distance between bottom connections = L-68

8

34

Bottom connections = 68

60 min

34

8

Bottom connections = 44

b

110

a

a = 77.5mm b = L - (2 x a)

12

BBOE (not flow specific)

12

c = H - 220 L = (Number of tubes x 75) + 5mm

= Water inlet = Water outlet

H = Height

Vent 1/8" BSP

V20

55

V10

25

DÉCOR H11 & H22 Connection Dimensions H = (Number of tubes x 75)+5

H11 Side connections = 54

Fixing brackets

H22 Side connections = 108

80 min

34

Central distance between water connections = H-68

34

5 70 5

Fixing brackets

33 110

Wall Bracket Dimensions H = (Number of tubes x 75)+5

33 52

8

8.2

12

100 min

Connection Dimensions

25

Wall Bracket Positioning Length from 600mm to 1200mm

L 150

150

Vent

4 Tubes = Water inlet = Water outlet

b

b

b

b

150

150

120

40

H

Or Plug

150 H

Plug

150

L

H

L b

110

150 110

150

L b

120

Vent

Wall Bracket Positioning Length from 1400mm to 1800mm

H 110

(Top Bottom Same End)

110

Not suitable for TBSE

6 to 10 Tubes b = L - 300

H = (Number of tubes x 75) + 5mm

Vent 1/2" BSP

4 Tubes

40

Water Connection

6 to 10 Tubes

b = L - 300 2 H = (Number of tubes x 75) + 5mm L = Length

Connections the

All TS4 (600mm high only) models must have the supplied diverter fitted inside the radiator prior to installation.

4 x 1/2 inch, including plug and vent (H11, H22 and H28) 2 x 1/2 inch BOE, including plug and vent (V10 and V20) 2 x 1/2 inch BOE, including plug and vent (TS4 2000mm high) 6 x 1/2 inch, including plug and vent (TS4 600mm high)

N.B. For H11, H22 and H28, the use of TBSE (Top Bottom Same End) connections is not suitable.

All MYSON DÉCOR following connections: H V T T

radiators

are

fitted

with


D É C O R Te c h n i c a l I n f o r m a t i o n

17

DÉCOR H28

Side connections = 64

Floor Mounting Dimensions Length from 1000mm to 1200mm

Not suitable for TBSE (Top Bottom Same End) Vent

Floor Mounting Dimensions

Adjustable Foot

119

90 to 120

34 34 Distance between water connections = H-68

5 70 5

Water Connection

33 119 H = (Number of tubes x 75)+5

Connection Dimensions

8

100 min

Connection Dimensions

Floor Mounting Dimensions Length from 1400mm to 2200mm

a=

L - 190 2

Plug Or Plug

Vent

= Water inlet = Water outlet

95

Vent 1/2" BSP

95

95

a

a

95

DÉCOR TS4 (600 & 2000)

34 Distance between bottom connections = L-68

H = Height

H = Height

a 25

Vent

Wall Bracket Dimensions*

L a a 25

Plug

a

H

2000mm high 34

8.2

Plug

12 a = 74mm

25

25

L = 308mm to 828mm

Vent 1/2" BSP

Vent

Water Connection TS4 (2000 high) = Water inlet = Water outlet

b = L - (2 x a)

= Water inlet = Water outlet

60 min

16

Bottom connections = 54

Wall Bracket Positioning* L b

70

Fixing brackets

18.5 Bottom connections = 54 Side connections = 54

TS4 (600 high)

33

Fixing brackets

34

Water Connection

Pitch

16

34

14

H

600mm high Distance between bottom connections = L-68

Connection Dimensions (2000mm High) 70

60 min

Pitch

33

Central distance between water connections = H-37

14

18.5

Connection Dimensions (600mm High)

25

Vent 1/8" BSP

*suitable for 600 & 2000mm high

NB: TS4 (600mm high only) models must have the supplied diverter fitted inside the radiator prior to installation.

Operating Pressures

Mounting Brackets

Every MYSON DÉCOR radiator is tested to a pressure of 6 bar (87 psi) and is suitable for a working pressure of up to 4.6 bar (66.7 psi).

All MYSON DÉCOR radiators are supplied with the appropriate standard brackets. V10, V20, H11, H22 and TS4 radiators are supplied with wall mounting brackets and the H28 radiator is supplied with floor mounting brackets only.

N.B. Because of the narrow waterways in longer DÉCOR TS4 radiators, care must be taken to ensure that the system pressure is sufficient to feed the whole radiator. Pressure loss data can be supplied if required.

Mounting feet for floor fixing and support for ceiling fixings can be supplied for the V10 and TS4 (2000mm high) radiator, only at the time of ordering.


18

DÉCOR Sizes & Outputs

(with fins)

DÉCOR V10

DÉCOR V20

DÉCOR H11

DÉCOR V10 Height 2000 mm

No. of Tubes

Width (mm - inches)

Output (watts)

Output (Btu/h)

Order Code

6 8 10

455 - 18 605 - 24 755 - 30

991 1322 1652

3381 4511 5637

6V10200 8V10200 10V10200

No. of Tubes

Width (mm - inches)

Output (watts)

Output (Btu/h)

Order Code

8 11 13 16 18

605 - 24 830 - 33 980 - 39 1205 - 48 1355 - 54

680 935 1105 1360 1530

2320 3190 3770 4640 5220

8V20060 11V20060 13V20060 16V20060 18V20060

DÉCOR V20

Height 600 mm

DÉCOR H11 Length (mm - inches)

Output (watts)

Output (Btu/h)

Order Code

4 Tube 305 mm

600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72

347 462 578 694 809 1040

1184 1576 1972 3262 2760 3548

4H11060 4H11080 4H11100 4H11120 4H11140 4H11180

6 Tube 455 mm

600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72

478 638 797 956 1116 1435

1631 2177 2719 3262 3808 4896

6H11060 6H11080 6H11100 6H11120 6H11140 6H11180

8 Tube 605 mm

600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72

602 802 1003 1204 1404 1805

2054 2736 3422 4108 4790 6159

8H11060 8H11080 8H11100 8H11120 8H11140 8H11180

10 Tube 755 mm

600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72

721 962 1202 1442 1683 2164

2460 3282 4101 4920 5742 7384

10H11060 10H11080 10H11100 10H11120 10H11140 10H11180


DÉCOR Sizes & Outputs

(with fins)

DÉCOR H22

DÉCOR H28

DÉCOR TS4

DÉCOR H22 Length (mm - inches)

Output (watts)

Output (Btu/h)

Order Code

6 Tube 455 mm

600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72

833 1110 1388 1666 1943 2498

2842 3787 4736 5684 6630 8523

6H22060 6H22080 6H22100 6H22120 6H22140 6H22180

8 Tube 605 mm

600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72

1027 1369 1711 2053 2395 3080

3504 4671 5838 7005 8172 10509

8H22060 8H22080 8H22100 8H22120 8H22140 8H22180

10 Tube 755 mm

600 - 24 800 - 32 1000 - 40 1200 - 47 1400 - 55 1800 - 72

1206 1608 2010 2412 2814 3618

4115 5486 6858 8230 9601 12345

10H22060 10H22080 10H22100 10H22120 10H22140 10H22180

Length (mm - inches)

Output (watts)

Output (Btu/h)

Order Code

2 Tube 155 mm

1000 - 40 1400 - 55 1800 - 72 2200 - 88

682 955 1228 1500

2327 3258 4190 5118

2H28100 2H28140 2H28180 2H28220

4 Tube 305 mm

1000 - 40 1400 - 55 1800 - 72 2200 - 88

1195 1673 2151 2629

4077 5708 7339 8970

4H28100 4H28140 4H28180 4H28220

DÉCOR H28

DÉCOR TS4 No. of Tubes

Width (mm - inches)

Output (watts)

Output (Btu/h)

Order Code

Height 600 mm

15 21 25 31 35

588 - 23 828 - 33 1028 - 41 1228 - 49 1428 - 56

506 708 843 1045 1180

1726 2416 2876 3566 4026

15TS4060 21TS4060 25TS4060 31TS4060 35TS4060

Height 2000 mm

8 11 13 16 18 21

308 - 12 428 - 17 508 - 20 628 - 25 708 - 28 828 - 33

936 1287 1521 1872 2106 2457

3194 4391 5190 6387 7186 8383

8TS4200 11TS4200 13TS4200 16TS4200 18TS4200 21TS4200

19


20

DÉCOR General Specifications

General Specifications Approval and Certification All

MYSON

All systems must be designed with suitable pipe sizing (15mm or DÉCOR

radiators

are

manufactured and tested to EN 442.

22mm minimum depending on the length of run) and with a pump or adequate pump head. Failure to do this may lead to trapped air and cold spots because of insufficient pressure and

All MYSON hydronic DÉCOR radiators carry

water flow will not drive the air from the radiator. The taller and

a 10 year guarantee from date of installation

more tubes a radiator has, the more likely this is to happen.

against defects caused by faulty materials or manufacture.

The recommendations of BS 7593, Code of Practice for treatment of water in domestic central heating systems, should be observed.

2

2

2

All MYSON sealed electric DÉCOR radiators carry a 2 year guarantee from date of installation

Safety Precautions

against defects caused by faulty materials or

Radiators are hot when in use, and as such, present a risk of burns

manufacture.

to users on prolonged contact. The temperature of a radiator is

Paint Finish

dependent on the temperature of the system water, as set by the system installer or user. Installers and users should ensure that

Every MYSON DÉCOR radiator undergoes a multi-stage

those who may come into close proximity to hot radiators are aware

pre-treatment process followed by an epoxy polyester primer

of the risk of burns. Installers and users should take all necessary

coating. A stoved epoxy polyester powder coat in white (RAL

steps to minimise the risks of burns. If the risk is significant,

9016) is applied to all front and rear surfaces allowing the

consideration should be given to installing low surface temperature

MYSON DÉCOR to be fitted without further painting. Other

radiators, or to placing guards in front of the radiators.

colours are available, please refer to page 21.

Tube Dimensions Fixings For the correct installation of radiators it is essential that the fixing of the radiator is carried out in such a way that it is suitable for intended use AND predictable misuse. A number of elements need to be taken into consideration including the fixing method used to secure the radiator to the wall, the type and condition of the wall itself, and any additional potential forces or weights that may happen to be applied to the radiator, prior to finalising installation.

Headers Triangular 51mm x 42mm x 42mm header: thickness 1.5mm Heating tubes Flat 70mm x 11mm: thickness 1.25mm

Heat Output The heat outputs for all MYSON DÉCOR radiators can be

Application

found on pages 18 and 19. The tabulated figures are quoted in

MYSON DÉCOR radiators are for use on two pipe, pumped,

accordance with EN 442 for a mean water to air temperature of

indirect, domestic and commercial central heating installations,

50oC. When the difference is not 50oC, the output should be

with a maximum working temperature of 100oC. The system

multiplied by the appropriate factor from within the table below:

should be designed in accordance with BS 5449 or BS 6880 as appropriate, with particular care taken to avoid air entry or water discharge. We do not recommend the use of single feed indirect cylinders, as the possibility of aeration due to water interchange may lead to corrosion.

Centigrade

Factor

Fahrenheit

40°C

0.75

72°F

45°C

0.87

81°F

50°C

1.00

90°F

55°C

1.13

99°F

The installation work must be carried out in accordance with

60°C

1.27

108°F

recognised good practice, and precautions taken to avoid

65°C

1.41

117°F

contamination which could lead to corrosion. If a corrosion

70°C

1.55

126°F

inhibitor or other water treatment is to be used, the Manufacturer’s Instructions must be strictly followed.


D É C O R C o l o u r B o a rd

Colour Board (Hydronic Models Only)

White/Ref. 1S Ral 9016

P e rg a m o n / Ref. 64

Jasmin/ Ref. 63

Natura/ Ref. 73

Bahama Beige/ Ref. 61

Metallic Silver/ Ref. 27

Edelweiss/ Ref. 59

Camelia/ Ref. 53

Manhattan/ Ref. 31

Pastel Rose/ Ref. 54

Pastel Blue/ Ref. 56

Cool Mint/ Ref. 70

Keywest/ Ref. 80

IMPORTANT We can match any colour - please supply RAL reference. Due to print restrictions, exact colour match of swatches is not possible. However, every effort has been made to ensure as much accuracy as possible.

21


22

Electric COLUMN & DÉCOR

Available Now

Electric COLUMN. The proportions, scale and detailing of the round tube Electric COLUMN combine to give a symmetry and elegance that feels just right. Available in horizontal and vertical styles with a paint finish that is second to none, there is a size and column configuration to suit every need.

Electric COLUMN Horizontal.

Electric DÉCOR. Electric COLUMN Vertical.

The Electric DÉCOR offers a stunning alternative to mainstream radiators with its distinctive and contemporary flat tube design. Available in horizontal and vertical styles with high quality white gloss paint finish, you can find a model to enhance the look of any interior.

Electric DÉCOR Horizontal.

Electric DÉCOR Vertical.


E l e c t r i c C O L U M N & D É C O R Te c h n i c a l I n f o r m a t i o n

Electric COLUMN Technical Information Electric COLUMN Horizontal Order Code

Width (mm)

Height (mm)

Heat Outputs (watts)

E8-3060 E10-3060 E12-3060 E14-3060

450 550 650 750

600 600 600 600

500 750 1000 1250

133-143

94-104

Electric COLUMN Vertical Order Code

Width (mm)

Height (mm)

Heat Outputs (watts)

E8-2180 E12-2180

400 600

1845 1845

1000 1500

Electric COLUMN Horizontal

Electric COLUMN Vertical

Projection (mm)

Projection (mm)

Electric DÉCOR Technical Information Electric DÉCOR Horizontal Order Code

Width (mm)

Height (mm)

Heat Outputs (watts)

E6V20060 E8V20060 E11V20060 E13V20060

485 635 860 1010

600 600 600 600

500 750 1000 1250

106

75

Electric DÉCOR Vertical Order Code

Width (mm)

Height (mm)

Heat Outputs (watts)

E6V10180 E9V10180

455 680

1835 1835

1000 1500

Electric DÉCOR Horizontal

Electric DÉCOR Vertical

Projection (mm)

Projection (mm)

Wireless Thermostats Wall mounted wireless thermostats are available that will control one or more Electric COLUMN or Electric DÉCOR radiators in any one room, using only a single remote control!

23


MYSON Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UK T: 0845 402 3434, F: 0191 491 7568, sales@myson.co.uk, www.myson.co.uk

heatingthroughinnovation.

01.11.2011

MYSON


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.