A U D I T O R Iconstruction UM PLOT AREA:1,500sq.mt.
Capacity 350+100 persons
INTENT:
To design an auditorium on a neighboring plot and resolve it in terms of:Entry/exit,Visual angles,Seating capacity,Acoustic To resolve structurally the balcony component of the auditorium.
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
CANAL
CANAL
20MM THK CARPET 20MM THK COIR BASE
FLOATING MARKET
UPPER LOBBY EMERGENCY EXIT
EMERGENCY EXIT
LOBBY
AC PLANT ROOM
+1.5 M
ENTRY ENTRANCE LOBBY
ENTRY
+ 7.35m
+0.45M
TOILET BLOCK
UP
EXHIBITION +1.5 M
+0.45M ENTRANCE
UP
REHERSAL ROOM
EXIT LOBBY
OFFICE
+.6m FIRE EXIT
12 DIA CHAIRS AT 150 CENTERS
+3m
STAGE
+ 1.35m + 0.9m + 0.45m
FIRE EXIT
+.45
AIR LOCK LOBBY
12 TOR R/F FOR RAKER SLAB
SERVICE ENTRANCE
WAITING
TOILET BLOCK
STORAGE
+ 4.5 m
+ 4.35m
+2.7m
DOWEL
CONTROLL ROOM
GREEN ROOM
DRY CAFE/ CANTEEN
DRY CAFE/ CANTEEN
100 MM THK RCC PRECAST SLAB
+8.40m
+0.6M
TRANSIT STOP
STORE/ SERVICE ENTRY
DRY CAFE
0.0 M
AIR LOCK LOBBY
APPRON +1.35
8MM DISTRIBUTION R/F
ROAD
entry
GROCERY +1.5 M
ROAD
CAFE
waiting y
UGT
BOX OFFICE
+1.5 M
up
SECTION sc SC 1:200
KEY SECTION
WAITING
stack
trolle
BACKSTAGE
ADMIN
+1.5 M
+1.35
EXIT
exit
299
VIP PARKING GREEN ROOM
VIP ROOM
GREEN ROOM
0
workshop
rehersal room
VISITOR PARKING
toilet block
toilet block
UNLOADING DECK
security
store room
security
GROUND FLOOR PLAN
SC 1:500
700
KEY PLAN
100
MAIN ROAD
600X1200 CROSS BEAM UPPER LOBBY
345X1200 RCC COLUMNS
UPPER LOBBY
18 MM TOR FULCRUM BEAM REINFORCEMENT
AHU
ENTRY
EXIT
B
880
150
500
400
700
SECTION THROUGH BALCONY SLAB
SC 1:20
100
+3.0m EXIT
DN
1000
EXIT LOBBY
EXIT EXIT
+.45 AIR LOCK LOBBY
AIR LOCK LOBBY
APPRON
ROAD ROAD
STAGE
VIP PARKING
500
BACKSTAGE
A
toilet block wc
toilet block
wc
SECTION THROUGH RAKER BEAM
SC 1:20
UPPER LOBBY
VISITOR PARKING changing rooms
changing rooms
changing rooms
changing rooms
security
PLAN AT BALCONY LEVEL sc
PLAN AT BALCONY LEVEL
SC 1:200
150MM T.W. HANDRAIL DOWEL
16MM REINFORCEMENT BARS FOR RAKER BEAM
12MM REINFORCEMENT BARS FOR BEAM 8MM DIA LINKS AT 75 CENTERS
8MM DIA LINKS AT 75 CENTERS
12MM REINFORCEMENT BARS FOR SLAB
18MM ACOUSTICAL PLASTER
+8.40m
20MM THK CARPET 20MM THK COIR BASE 100 MM THK RCC PRECAST SLAB 12MM REINFORCEMENT MESH 16 TOR FULCRUM BEAM R/F 12 DIA CHAIRS AT 150 CENTERS
12MM REINFORCEMENT BARS FOR PARAPET WALL
CONTROLL ROOM
8MM DIA LINKA AT 150 CENTERS
+ 4.5 m
16MM REINFORCEMENT BARS FOR RAKER BEAM 8MM DIA LINKS AT 150 CENTERS
12000
+3m
20000
80000
8MM DIA LINKS AT 75 CENTERS 12MM DIA CHAIRS AT150 CENTERS
18 MM TOR FULCRUM BEAM REINFORCEMENT
DRY CAFE
0.0 M
10000 6000
DETAIL AT - B
SC 1:10
DETAIL AT - A
SC 1:10
STRIP SECTION THROUGH BALCONY PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
8MM DIA LINKS AT 150 CENTERS
1000
150x300 RAKER BEAM AT 3000MM CENTERS 500X900 FULCRUM BEAM
345X1200 RCC COLUMNS
SC 1:50
semester VII CONSTRUCTION
33
AUDITO