econoMaster EM
Drive components
end stop
motor emergency open battery
control unit
mains adapter
belt connection
belt
carriage
lock (optional)
pulley cover support
USBDL
DPWFS
Technical data Type of drive
econoMaster EM 1 door leaf
Clearance width
[1]
2 door leaves
800 – 1250 mm
800 – 2500 mm
Clearance height [1]
max. 2500 mm
Weight of door leaf
max. 80 kg/leaf
Mains voltage
230 V/AC, 50 Hz
Power consumption
max. 160 VA (50 VA during operation)
Hold open time
0 – 60 s
Opening speed
max. 0,7 m/s
Closing speed
max. 0,5 m/s
Winter opening width
50 – 100 % of clear opening width
Ambient temperature
for dry rooms only; -15 °C up to +50 °C
Protection class
[1]
IP 20
Standard widths with regard to total dimension of drive system and local situation. Special solutions on request.
7