automatic_entrance_systems

Page 7

econoMaster EM

Drive components

end stop

motor emergency open battery

control unit

mains adapter

belt connection

belt

carriage

lock (optional)

pulley cover support

USBDL

DPWFS

Technical data Type of drive

econoMaster EM 1 door leaf

Clearance width

[1]

2 door leaves

800 – 1250 mm

800 – 2500 mm

Clearance height [1]

max. 2500 mm

Weight of door leaf

max. 80 kg/leaf

Mains voltage

230 V/AC, 50 Hz

Power consumption

max. 160 VA (50 VA during operation)

Hold open time

0 – 60 s

Opening speed

max. 0,7 m/s

Closing speed

max. 0,5 m/s

Winter opening width

50 – 100 % of clear opening width

Ambient temperature

for dry rooms only; -15 °C up to +50 °C

Protection class

[1]

IP 20

Standard widths with regard to total dimension of drive system and local situation. Special solutions on request.