Column radiators Technology I/2015-N
Buch_020_Roehrenradiator_128_ex.indb 1
5/22/2015 12:23:08 PM
Mode l d e s c rip t io n
Example standard without built-in valve: Example: 3060 3
060
Number of columns, Depth (3 columns)
Height in cm (60 cm)
Example with built-in valve: Example: 2180V 2
180
V
Number of columns, Depth (2 columns)
Height in cm (180 cm)
with factory preset kv built-in valve
M
4
090
SANO - radiator
Number of columns, Depth (4 columns)
Height in cm (90 cm)
4
F
5
200
Number of elements (4-7) = height
Bench-radiator
Number of columns, Depth (5 columns)
Length in cm (200 cm)
Example SANO-Radiator: Example: M4090
Example Bench-Radiator: Example: 4F5200
Buch_020_Roehrenradiator_128_ex.indb 2
5/22/2015 12:23:08 PM
Column radiators
Contents
Outputs
Connection images and dimensional drawings
Arbonia individual
3
Sano-radiator
4
Sano-radiators with built-in valve
5
Cambiotherm - replacement radiator
6
Standard column radiators with and without built-in valve
Tender specification, sizes
2
Standard column radiators with built-in valve
7
Sano-radiators with and without built-in valve
10
Cambiotherm - replacement radiator
13
Standard column radiators with and without built-in valve
14
Sano-radiators with and without built-in valve
35
Cambiotherm - replacement radiator
35
Connection options flow/return 2-pipe and 1-pipe connections without built-in valve Dimensional drawings 2-pipe connections with built-in valve Dimensional drawings Air vent and drain
63
Special constructions Angled and curved versions Room divider installation Fixing with bench bracket ZB0226 Round pipe feet, welded feet Bench version
70
Multi-section radiators
84
Technical data
Technical data
Standard column radiators
Outputs
Tender specification, range available and sizes
Page
Connections
Sections
• • • •
69
Arbonia individual
• • • • •
• Coupled column radiator • Coupled column radiators
86
Fixing with brackets
87
• Possible combinations - fixings according to VDI 6036 • Without rear lugs (built into wall bracket ,quick assembly bracket,
Fixing
Fixing and Dimensional drawings
On request • High-pressure version • Special heights, heights above 3000 mm • Insert pipe
wall bracket, clamping bracket, soil stand bracket and lifting bracket)
Accessories and miscellaneous
112
Further information
Sample order
120
Surface finish
124
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 1
4echnology 2015-N
Further information
Accessories
Accessories
• With rear lugs (wall bracket)
1
5/22/2015 12:23:08 PM
Standard column radiators Tender specification, range available and sizes Standard column radiators
Tender specification
Range available
Tender specification, sizes
Arbonia column radiators 2–6 columns of steel; individual elements (length 45 mm) as welded assembly, consisting of head pieces (band steel pressings) and precision round steel pipes. Blocks welded together from elements up to the maximum length of the delivery unit. Ready to install with 4 threaded plugs for flow and return, and for air vent and drain. Edges rounded on all sides with Rmin = 2 mm. Coating according to DIN 55900 part 1 and part 2. Design characteristics comply with the basic principles for the testing of the occupational safety (statutory accident insurance). Awarded compliance with high hygiene requirements from the Institut Prof. Dr. Pieldner / Stuttgart.
• 5 depths: 65–225 mm (2–6 columns) • 21 Heights: 180–3000 mm • Length: − calculation: number of elements x 45 mm − length gradation: 45 mm ( 1 element) − minimum length: 270 mm (6 elements) − maximum length see paragraph "Maximum length" • 2-pipe connections, side • Can be installed as a bench For column radiators with connections on the same side, starting from a certain length and height an insert pipe will also be delivered for an additional price in order to guarantee correct water circulation.
Pressure and leak tested. Heat output tested and measured in accordance with EN 442. Awarded the RAL quality mark. CE-compliant. Suitable for hot water heating systems in accordance with DIN 18380 and water quality in accordance with VDI 2035, ÖNORM H5195 and SWIKI 97-1. Maximum permissible operating temperature: 110 °C Max. operating pressure: 2–6-columns 10 bar / 1000 kPa 2–6-columns 16 bar / 1600 kPa (high-pressure version) Suitably packed for transport.
Maximum length For reasons of weight and transport, column radiators can only be shipped from the factory as a single piece up to a maximum length. If the maximum length is exceeded in a single piece, the column radiators will be delivered in several blocks. These blocks must be coupled on site, or if necessary at the factory.
Version 2 columns
3 columns
4 columns
5 columns
6 columns
2
The overall length for column radiators is limited to three blocks. Column radiators in the high-pressure version cannot be coupled. The overall length for the high-pressure version is thus limited to the maximum number of elements per block.
Height [mm]
Max. number of elements first block
190–2000
66
2970
22
22
2200–3000
42
1890
22
22
Length [mm]
Max. number of elements second block
Max. number of elements third block
190–1800
66
2970
22
22
2000–2200
59
2655
22
22
2500–3000
30
1350
22
22
190–1200
66
2970
22
22
1500–1800
54
2430
22
22
2000–2200
44
1980
22
22
2500–3000
30
1350
22
22
180–1000
66
2970
22
22
1100–1200
44
1980
22
22
1500–2500
30
1350
22
22
2800–3000
26
1170
22
22
180–900
66
2970
22
22
1000
58
2610
22
22
1100–1200
44
1980
22
22
1500–2000
30
1350
22
22
2200–3000
22
990
22
22
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 2
Technical specifications subject to change.
5/22/2015 12:23:08 PM
Standard column radiators with built-in valve Tender specification, range available and sizes Standard column radiators with built-in valve
Range available
Arbonia column radiators with built-in valve 2–6 columns of steel; individual elements (length 45 mm) as welded assembly, consisting of head pieces (band steel pressings) and precision round steel pipes. Blocks welded together from elements up to the maximum length of the delivery unit. With integrated, adjustable valve insert. The kV value is preset at the factory and adjusted to the heat output. Ready to install with connections for flow and return and for air vent. Optional connection for drain. Edges rounded on all sides with Rmin = 2 mm. Coating according to DIN 55900 part 1 and part 2. Design characteristics comply with the basic principles for the testing of the occupational safety (statutory accident insurance). Awarded compliance with high hygiene requirements from the Institut Prof. Dr. Pieldner / Stuttgart. Pressure and leak tested. Heat output tested and measured in accordance with EN 442. Awarded the RAL quality mark.
• 5 depths: 65–225 mm (2–6 columns) • 21 Heights: 180–3000 mm • Length: − calculation: number of elements x 45 mm − length gradation: 45 mm ( 1 element) − minimum length: 270 mm (6 elements) − maximum length see paragraph "Maximum length" • Can be installed as a bench • Factory kV preset built-in valve, arranged above or below, right or left • Standard connection: − 2-pipe connection bottom, on same side (on the side of the valve) with hub distance 50 mm − connection size: thread 1/2’’ internal thread − flow welded into the 1st element, return into the 2nd element − for the version with valve arranged at the bottom, two air vents are provided • Thermostatic sensor head is not included in the scope of delivery, must be ordered as an accessory • Not available in high-pressure version
Tender specification, sizes
Tender specification
CE-compliant. Suitable for hot water heating systems in accordance with DIN 18380 and water quality in accordance with VDI 2035, ÖNORM H5195 and SWIKI 97-1. Maximum permissible operating temperature: 110 °C Max. operating pressure: 2–6-columns 10 bar / 1000 kPa Suitably packed for transport.
Maximum length For reasons of weight and transport, column radiators can only be shipped from the factory as a single piece up to a maximum length. If the maximum length is exceeded, the column radiators will be delivered in several blocks.
Version 2 columns
3 columns
4 columns
5 columns
6 columns
These blocks must be coupled on site, or if necessary at the factory. Built-in valve bottom not possible. The overall length for column radiators is limited to three blocks.
Height [mm]
Max. number of elements first block
190–2000
66
2970
22
22
2200–3000
42
1890
22
22
Length [mm]
Max. number of elements second block
Max. number of elements third block
190–1800
66
2970
22
22
2000–2200
59
2655
22
22
2500–3000
30
1350
22
22
190–1200
66
2970
22
22
1500–1800
54
2430
22
22
2000–2200
44
1980
22
22
2500–3000
30
1350
22
22
180–1000
66
2970
22
22
1100–1200
44
1980
22
22
1500–2500
30
1350
22
22
2800–3000
26
1170
22
22
180–900
66
2970
22
22
1000
58
2610
22
22
1100–1200
44
1980
22
22
1500–2000
30
1350
22
22
2200–3000
22
990
22
22
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 3
Technology 2015-N
3
5/22/2015 12:23:08 PM
Sano-radiator Tender specification, range available and sizes Sano-radiator
Tender specification
Range available
Tender specification, sizes
Arbonia Sano-radiators 2–6 columns of steel; individual elements (length 65 mm) as welded assembly, consisting of head pieces (band steel pressings) and precision round steel pipes. Blocks welded together from elements up to the maximum length of the delivery unit. Ready to install with 4 threaded plugs for flow and return, and for air vent and drain. Edges rounded on all sides with Rmin = 2 mm. Coating according to DIN 55900 part 1 and part 2. Design characteristics comply with the basic principles for the testing of the occupational safety (statutory accident insurance).
• 5 depths: 65–225 mm (2–6 columns) • 20 standard heights: 260-3000 mm • Length: − calculation: (number of elements x 65 mm) - 20 mm − length gradation: 65 mm ( 1 element) − minimum length: 370 mm (6 elements) − maximum length see paragraph "Maximum length" • 2-pipe connections, side For Sano-radiators with connections on the same end, from a certain length and height an insert pipe is supplied at an extra charge to guarantee the correct water circulation.
Awarded compliance with high hygiene requirements from the Institut Prof. Dr. Pieldner / Stuttgart. Pressure and leak tested. Heat output tested and measured in accordance with EN 442. CE-compliant. Suitable for hot water heating systems in accordance with DIN 18380 and water quality in accordance with VDI 2035, ÖNORM H5195 and SWIKI 97-1. Maximum permissible operating temperature: 110 °C Max. operating pressure: 2–6-columns 10 bar / 1000 kPa 2–6-columns 16 bar / 1600 kPa (high-pressure version) Suitably packed for transport.
Maximum length For reasons of weight and transport, Sano-radiators can only be shipped from the factory as a single piece up to a maximum length. If the maximum length is exceeded in a single piece, the column radiators will be delivered in several blocks. These blocks must be coupled on site, or if necessary at the factory.
Version 2 columns
3 columns
4 columns
5 columns
6 columns
4
The overall length for Sano-radiators is limited to three blocks. Column radiators in the high-pressure version cannot be coupled. The overall length for the high-pressure version is thus limited to the maximum number of elements per block.
Max. number of elements second block
Max. number of elements third block
Height [mm]
Max. number of elements
260–2000
46
2970
15
15
2200–3000
30
1930
15
15
Length [mm]
260–2000
46
2970
15
15
2200–3000
30
1930
15
15
260–2000
46
2970
15
15
2200–3000
30
1930
15
15
260–1500
46
2970
15
15
1800–2000
38
2450
15
15
2200–2500
30
1930
15
15
2800–3000
26
1670
15
15
260–1200
46
2970
15
15
1500
42
2710
15
15
1800–2000
32
2060
15
15
2200–2500
26
1670
15
15
2800–3000
21
1345
15
15
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 4
Technical specifications subject to change.
5/22/2015 12:23:08 PM
Sano-radiators with built-in valve Tender specification, range available and sizes Sano-radiators with built-in valve
Range available
Arbonia Sano-radiators with built-in valve 2–6 columns of steel; individual elements (length 65 mm) as welded assembly, consisting of head pieces (band steel pressings) and precision round steel pipes. Blocks welded together from elements up to the maximum length of the delivery unit. With integrated, adjustable valve insert. The kV value is preset at the factory and adjusted to the heat output. Ready to install with connections for flow and return and for air vent. Connection for drain optional. Edges rounded on all sides with Rmin = 2 mm. Coating according to DIN 55900 part 1 and part 2. Design characteristics comply with the basic principles for the testing of the occupational safety (statutory accident insurance). Awarded compliance with high hygiene requirements from the Institut Prof. Dr. Pieldner / Stuttgart. Pressure and leak tested. Heat output tested and measured in accordance with EN 442.
• 5 depths: 65–225 mm (2–6 columns) • 20 standard heights: 260-3000 mm • Length: − calculation: (number of elements x 65 mm) - 20 mm − length gradation: 65 mm ( 1 element) − minimum length: 370 mm (6 elements) − maximum length see paragraph "Maximum length" • Factory kV preset built-in valve, arranged above or below, right or left • Standard connection: − 2-pipe connection bottom, on same side (on the side of the valve) with hub distance 50 mm − connection size: thread 1/2’’ internal thread − flow welded into the 1st element, return into the 2nd element − for the version with valve arranged at the bottom, two air vents are provided • Thermostatic sensor head is not included in the scope of delivery, must be ordered as an accessory • Not available in high-pressure version
Tender specification, sizes
Tender specification
CE-compliant. Suitable for hot water heating systems in accordance with DIN 18380 and water quality in accordance with VDI 2035, ÖNORM H5195 and SWIKI 97-1. Maximum permissible operating temperature: 110 °C Max. operating pressure: 2–6-columns 10 bar / 1000 kPa Suitably packed for transport.
Maximum length For reasons of weight and transport, Sano-radiators can only be shipped from the factory as a single piece up to a maximum length. If the maximum length is exceeded in a single piece, the column radiators will be delivered in several blocks.
Version 2 columns
3 columns
4 columns
5 columns
6 columns
These blocks must be coupled on site, or if necessary at the factory. Built-in valve bottom not possible. The overall length for Sano-radiators is limited to three blocks.
Length [mm]
Max. number of elements second block
Max. number of elements third block
2970
15
15
30
1930
15
15
46
2970
15
15
30
1930
15
15
Height [mm]
Max. number of elements
260–2000
46
2200–3000 260–2000 2200–3000 260–2000
46
2970
15
15
2200–3000
30
1930
15
15
260–1500
46
2970
15
15
1800–2000
38
2450
15
15
2200–2500
30
1930
15
15
2800–3000
26
1670
15
15
260–1200
46
2970
15
15
1500
42
2710
15
15
1800–2000
32
2060
15
15
2200–2500
26
1670
15
15
2800–3000
21
1345
15
15
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 5
Technology 2015-N
5
5/22/2015 12:23:09 PM
Cambiotherm® Tender specification, range available and sizes Cambiotherm
Tender specification
Range available
Tender specification, sizes
Arbonia Cambiotherm 2–6 columns of steel; individual elements (length 45 mm) as welded assembly, consisting of head pieces (band steel pressings) and precision round steel pipes. Blocks welded together from elements up to the maximum length of the delivery unit. Ready to install with 4 threaded plugs for flow and return, and for air vent and drain. With identical pipe connection dimensions as DIN steel radiators and DIN cast iron radiators according to DIN 4703. Edges rounded on all sides with Rmin = 2 mm. Coating according to DIN 55900 part 1 and part 2. Design characteristics comply with the basic principles for the testing of the occupational safety (statutory accident insurance).
• • • •
5 depths: 65–225 mm (2–6 columns) 7 height: 270–1070 mm (hub distance: 200–1000 mm) More heights (hub distance) on request Length: − calculation: number of elements x 45 mm − length gradation: 45 mm ( 1 element) − minimum length: 270 mm (6 elements) − maximum length see paragraph "maximum length" • 2-pipe connections, side For Cambiotherm with connections on the same end, from a certain length and height an insert pipe is supplied to guarantee correct water circulation.
Pressure and leak tested. Heat output tested and measured in accordance with EN 442. Awarded the RAL quality mark. CE-compliant. Suitable for hot water heating systems in accordance with DIN 18380 and water quality in accordance with VDI 2035, ÖNORM H5195 and SWIKI 97-1. Maximum permissible operating temperature: 110 °C Max. operating pressure: 2–6-columns 10 bar / 1000 kPa 2–6-columns 16 bar / 1600 kPa (high-pressure version) Suitably packed for transport.
Maximum length For reasons of weight and transport, Cambiotherm can only be shipped from the factory as a single piece up to a maximum length. If the maximum length is exceeded in a single piece, Cambiotherm is delivered in several blocks. These blocks must be coupled on site, or if necessary in the factory.
The overall length of Cambiotherm is limited to three blocks. Cambiotherm in the high-pressure version cannot be coupled. The overall length for the high-pressure version is thus limited to the maximum number of elements per block.
Height [mm]
Max. number of elements first block
Length [mm]
Max. number of elements second block
2 columns
190–1070
66
2970
22
22
3 columns
190–1070
66
2970
22
22
4 columns
190–1070
66
2970
22
22
180–970
66
2970
22
22
1070
44
1980
22
22
180–670
66
2970
22
22
970
58
2610
22
22
1070
44
1980
22
22
Version
5 columns
6 columns
6
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 6
Max. number of elements third block
Technical specifications subject to change.
5/22/2015 12:23:09 PM
Standard column radiators Technical data Standard column radiators
Technical data Height 180–500 mm Heat output EN 442
Height H [mm]
Depth D [mm]
Φ ΔT 60K ΦL ΔT 50K Φ ΔT 42K Φ ΔT 30K 90/70/20°C 75/65/20°C 70/55/20°C 55/45/20°C Version [watts/el.] [watts/el.] [watts/el.] [watts/el.]
Exponent n [ ]
water Ø content Mass Surface per Standard Radiper per element water ated element element W flow rate portion M A [l/eleqms s [kg/el.] [m²/el.] ment] [kg/h el.] [%]
185
5018
40
32
26
16
1,29
0,89
0,08
0,62
2,5
30
225
6018
49
39
31
20
1,31
1,08
0,01
0,74
2,8
27
190
260
300
350
400
450
500
65
2019
18
15
12
8
1,23
0,33
0,03
0,28
1,2
49
105
3019
25
20
16
11
1,27
0,50
0,05
0,40
1,7
38
145
4019
33
27
22
14
1,25
0,66
0,07
0,52
2,2
33
65
2026
25
20
16
11
1,25
0,42
0,04
0,34
1,6
49
105
3026
35
28
22
14
1,31
0,63
0,07
0,48
2,2
38
145
4026
46
36
29
19
1,30
0,84
0,09
0,63
2,8
33
185
5026
56
45
36
22
1,33
1,11
0,11
0,78
3,6
30
225
6026
67
53
42
26
1,36
1,34
0,13
0,93
4,0
27
65
2030
30
24
19
12
1,26
0,47
0,05
0,37
1,9
49
105
3030
41
33
26
16
1,33
0,70
0,08
0,53
2,7
38
145
4030
54
43
34
21
1,33
0,93
0,10
0,69
3,4
33
185
5030
67
53
42
26
1,36
1,23
0,13
0,86
4,1
30
225
6030
79
62
49
30
1,39
1,49
0,15
1,02
4,9
27
65
2035
35
28
22
14
1,31
0,53
0,06
0,41
2,2
49
105
3035
48
38
30
19
1,36
0,79
0,09
0,59
3,1
38
145
4035
63
49
39
25
1,35
1,06
0,12
0,77
4,0
33
185
5035
78
61
48
30
1,39
1,38
0,15
0,96
4,8
30
225
6035
92
72
56
34
1,41
1,67
0,18
1,14
5,7
27
65
2040
40
31
25
16
1,31
0,59
0,07
0,45
2,4
49
105
3040
55
43
34
21
1,36
0,88
0,10
0,65
3,5
38
145
4040
71
56
44
28
1,35
1,18
0,13
0,85
4,5
33
185
5040
88
69
55
34
1,39
1,53
0,17
1,06
5,5
30
225
6040
104
81
64
39
1,41
1,85
0,20
1,26
6,5
27
65
2045
44
35
28
18
1,31
0,65
0,07
0,49
2,8
49
105
3045
61
48
38
24
1,36
0,97
0,11
0,71
4,0
38
145
4045
79
62
50
31
1,35
1,30
0,15
0,93
5,0
33
185
5045
98
77
61
37
1,39
1,68
0,19
1,16
6,2
30
225
6045
115
90
71
43
1,41
2,03
0,22
1,38
7,2
27
65
2050
49
39
31
20
1,31
0,71
0,08
0,53
3,2
49
105
3050
68
53
42
26
1,36
1,06
0,12
0,77
4,4
38
145
4050
87
69
55
34
1,35
1,42
0,17
1,01
5,6
33
185
5050
108
85
67
41
1,39
1,83
0,21
1,26
6,9
30
225
6050
127
99
78
48
1,41
2,21
0,25
1,50
8,1
27
Technical data
180
For individual calculations of heat outputs, see "General Information" Length calculation: length in mm = number of elements x 45 mm Note extra charge for connection images.
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 7
Technology 2015-N
7
5/22/2015 12:23:09 PM
Standard column radiators Technical data Standard column radiators
Technical data Height 550–1200 mm Heat output EN 442
Technical data
Height H [mm]
550
600
750
900
1000
1100
1200
Depth D [mm]
Φ ΔT 60K ΦL ΔT 50K Φ ΔT 42K Φ ΔT 30K 90/70/20°C 75/65/20°C 70/55/20°C 55/45/20°C Version [watts/el.] [watts/el.] [watts/el.] [watts/el.]
Exponent n [ ]
water Ø content Mass Surface per Standard Radiper per element water ated element element W flow rate portion M A [l/eleqms s [kg/el.] [m²/el.] ment] [kg/h el.] [%]
65
2055
53
42
34
21
1,31
0,77
0,09
0,57
3,5
49
105
3055
74
58
46
29
1,36
1,16
0,14
0,83
4,7
38
145
4055
95
75
60
37
1,35
1,54
0,18
1,09
6,1
33
185
5055
118
93
73
45
1,39
1,99
0,23
1,36
7,5
30
225
6055
138
108
85
52
1,41
2,40
0,27
1,62
8,9
27
65
2060
58
46
37
23
1,31
0,83
0,10
0,61
3,8
49
105
3060
80
63
50
31
1,36
1,25
0,15
0,89
5,2
38
145
4060
103
81
64
40
1,35
1,66
0,20
1,17
6,6
33
185
5060
128
100
79
49
1,39
2,14
0,25
1,45
8,2
30
225
6060
150
117
92
56
1,41
2,58
0,29
1,74
9,7
27
65
2075
71
57
45
29
1,31
1,02
0,12
0,73
4,7
49
105
3075
99
78
62
39
1,36
1,52
0,18
1,07
6,5
38
145
4075
126
100
79
50
1,35
2,03
0,24
1,41
8,2
33
185
5075
157
123
97
60
1,39
2,59
0,30
1,75
10,1
30
225
6075
183
143
113
69
1,40
3,12
0,37
2,10
11,8
27
65
2090
84
67
54
34
1,31
1,20
0,15
0,84
5,8
49
105
3090
117
92
73
46
1,36
1,79
0,22
1,25
7,7
38
145
4090
148
117
93
58
1,35
2,39
0,29
1,65
9,6
33
185
5090
184
144
114
70
1,39
3,05
0,36
2,05
11,9
30
225
6090
215
168
132
81
1,40
3,67
0,44
2,45
14,0
27
65
2100
93
74
59
37
1,32
1,32
0,16
0,92
6,3
49
105
3100
130
102
81
51
1,36
1,98
0,24
1,37
8,4
38
145
4100
164
129
103
64
1,35
2,63
0,32
1,81
10,7
33
185
5100
202
158
125
77
1,38
3,35
0,40
2,25
13,0
30
225
6100
237
185
146
90
1,40
4,03
0,48
2,69
15,5
27
65
2110
102
81
65
41
1,32
1,44
0,18
1,00
6,9
49
105
3110
141
111
88
55
1,35
2,16
0,27
1,49
9,2
38
145
4110
179
141
112
70
1,35
2,88
0,35
1,97
11,6
33
185
5110
219
172
136
84
1,38
3,65
0,44
2,45
14,2
30
225
6110
257
201
158
97
1,40
4,40
0,53
2,93
16,9
27
65
2120
111
88
70
44
1,32
1,56
0,19
1,08
7,4
49
105
3120
152
120
95
60
1,35
2,34
0,29
1,60
10,0
38
145
4120
193
152
121
76
1,35
3,12
0,38
2,13
12,6
33
185
5120
237
186
147
91
1,38
3,96
0,48
2,65
15,4
30
225
6120
278
217
171
105
1,40
4,76
0,58
3,17
18,0
27
For individual calculations of heat outputs, see "General Information" Length calculation: length in mm = number of elements x 45 mm Note extra charge for connection images.
8
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 8
Technical specifications subject to change.
5/22/2015 12:23:09 PM
Standard column radiators Technical data Standard column radiators
Technical data Height 1500–3000 mm
Height H [mm]
1500
1800
2000
2200
2500
2800
3000
Depth D [mm]
Φ ΔT 60K ΦL ΔT 50K Φ ΔT 42K Φ ΔT 30K 90/70/20°C 75/65/20°C 70/55/20°C 55/45/20°C Version [watts/el.] [watts/el.] [watts/el.] [watts/el.]
Exponent n [ ]
water Ø content Mass Surface per Standard Radiper per element water ated element element W flow rate portion M A [l/eleqms s [kg/el.] [m²/el.] ment] [kg/h el.] [%]
65
2150
138
109
87
55
1,32
1,93
0,24
1,32
9,1
49
105
3150
187
147
117
73
1,35
2,89
0,36
1,96
12,3
38
145
4150
236
186
148
93
1,35
3,85
0,48
2,60
15,5
33
185
5150
286
225
178
111
1,37
4,87
0,60
3,24
18,5
30
225
6150
338
264
208
128
1,40
5,85
0,72
3,88
21,5
27
65
2180
164
130
104
66
1,32
2,29
0,29
1,56
10,8
49
105
3180
219
173
138
86
1,35
3,43
0,43
2,32
14,6
38
145
4180
277
219
174
110
1,34
4,58
0,57
3,08
18,4
33
185
5180
335
263
208
130
1,37
5,78
0,72
3,84
22,0
30
225
6180
395
309
244
151
1,39
6,95
0,86
4,60
25,5
27
65
2200
182
144
115
73
1,32
2,53
0,32
1,72
12,0
49
105
3200
241
190
151
95
1,34
3,80
0,48
2,56
16,3
38
145
4200
305
241
192
121
1,34
5,06
0,64
3,40
20,4
33
185
5200
365
287
227
141
1,37
6,38
0,80
4,24
24,3
30
225
6200
433
339
268
165
1,39
7,67
0,95
5,08
28,4
27
65
2220
199
158
126
80
1,32
2,78
0,35
1,88
13,2
49
105
3220
262
207
165
104
1,34
4,16
0,52
2,80
17,9
38
145
4220
332
262
209
131
1,34
5,55
0,70
3,72
22,4
33
185
5220
394
310
246
153
1,36
6,99
0,87
4,64
26,5
30
225
6220
469
367
290
179
1,39
8,40
1,05
5,55
31,0
27
65
2250
226
179
143
90
1,32
3,14
0,40
2,12
15,0
49
105
3250
293
231
184
116
1,34
4,71
0,59
3,16
20,3
38
145
4250
371
293
233
147
1,34
6,27
0,79
4,19
25,4
33
185
5250
436
343
272
170
1,36
7,90
0,99
5,23
29,8
30
225
6250
521
408
322
199
1,39
9,49
1,19
6,27
34,7
27
65
2280
253
200
160
101
1,33
3,50
0,44
2,36
16,8
49
105
3280
323
255
203
128
1,34
5,25
0,67
3,51
22,5
38
145
4280
409
323
257
162
1,34
7,00
0,89
4,67
28,2
33
185
5280
474
374
297
186
1,35
8,81
1,11
5,83
33,1
30
225
6280
571
448
354
220
1,38
10,59
1,33
6,99
38,6
27
65
2300
271
214
171
108
1,33
3,75
0,48
2,51
17,9
49
105
3300
341
270
215
136
1,33
5,62
0,71
3,75
24,0
38
145
4300
434
343
273
172
1,34
7,49
0,95
4,99
30,1
33
185
5300
500
394
313
196
1,35
9,42
1,19
6,23
35,3
30
225
6300
605
474
375
232
1,38
11,31
1,43
7,46
41,3
27
Technical data
Heat output EN 442
For individual calculations of heat outputs, see "General Information" Length calculation: length in mm = number of elements x 45 mm Note extra charge for connection images.
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 9
Technology 2015-N
9
5/22/2015 12:23:09 PM
Sano-radiator Technical data Sano-radiator
Technical data Height 260–550 mm Heat output EN 442
Technical data
Height H [mm]
260
300
350
400
450
500
550
Depth D [mm]
Φ ΔT 60K ΦL ΔT 50K Φ ΔT 42K Φ ΔT 30K 90/70/20°C 75/65/20°C 70/55/20°C 55/45/20°C Version [watts/el.] [watts/el.] [watts/el.] [watts/el.]
Exponent n [ ]
water Ø content Mass Surface per Standard Radiper per element water ated element element W flow rate portion M A [l/eleqms s [kg/el.] [m²/el.] ment] [kg/h el.] [%]
65
M 2026
31
25
20
13
1,25
0,42
0,04
0,34
1,6
49
105
M 3026
41
33
26
17
1,31
0,63
0,07
0,48
2,2
38
145
M 4026
53
42
34
21
1,30
0,84
0,09
0,63
2,8
33
185
M 5026
64
51
41
26
1,33
1,11
0,11
0,78
3,6
30
225
M 6026
78
61
49
30
1,36
1,34
0,13
0,93
4,0
27
65
M 2030
35
28
23
15
1,26
0,47
0,05
0,37
1,9
49
105
M 3030
47
37
30
19
1,33
0,70
0,08
0,53
2,7
38
145
M 4030
60
48
38
24
1,33
0,93
0,10
0,69
3,4
33
185
M 5030
74
58
46
29
1,36
1,23
0,13
0,86
4,1
30
225
M 6030
89
70
55
34
1,39
1,49
0,15
1,02
4,9
27
65
M 2035
40
32
25
16
1,31
0,53
0,06
0,41
2,2
49
105
M 3035
55
43
34
21
1,36
0,79
0,09
0,59
3,1
38
145
M 4035
70
55
44
27
1,35
1,06
0,12
0,77
4,0
33
185
M 5035
85
67
53
33
1,39
1,38
0,15
0,96
4,8
30
225
M 6035
103
81
63
39
1,41
1,67
0,18
1,14
5,7
27
65
M 2040
45
36
28
18
1,31
0,59
0,07
0,45
2,4
49
105
M 3040
62
48
38
24
1,36
0,88
0,10
0,65
3,5
38
145
M 4040
79
62
49
31
1,35
1,18
0,13
0,85
4,5
33
185
M 5040
97
76
60
37
1,39
1,53
0,17
1,06
5,5
30
225
M 6040
117
91
72
44
1,41
1,85
0,20
1,26
6,5
27
65
M 2045
49
39
31
20
1,31
0,65
0,07
0,49
2,8
49
105
M 3045
68
54
43
27
1,36
0,97
0,11
0,71
4,0
38
145
M 4045
88
69
55
34
1,35
1,30
0,15
0,93
5,0
33
185
M 5045
108
84
67
41
1,39
1,68
0,19
1,16
6,2
30
225
M 6045
131
102
80
49
1,41
2,03
0,22
1,38
7,2
27
65
M 2050
54
43
34
22
1,31
0,71
0,08
0,53
3,2
49
105
M 3050
75
59
47
29
1,36
1,06
0,12
0,77
4,4
38
145
M 4050
97
76
61
38
1,35
1,42
0,17
1,01
5,6
33
185
M 5050
119
93
73
45
1,39
1,83
0,21
1,26
6,9
30
225
M 6050
144
112
88
54
1,41
2,21
0,25
1,50
8,1
27
65
M 2055
59
47
37
24
1,31
0,77
0,09
0,57
3,5
49
105
M 3055
82
65
51
32
1,36
1,16
0,14
0,83
4,7
38
145
M 4055
106
83
66
41
1,35
1,54
0,18
1,09
6,1
33
185
M 5055
129
101
80
49
1,39
1,99
0,23
1,36
7,5
30
225
M 6055
158
123
97
59
1,41
2,40
0,27
1,62
8,9
27
For individual calculations of heat outputs, see "General Information" Length calculation: length in mm = number of elements x 65 mm - 20 mm Note extra charge for connection images.
10
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 10
Technical specifications subject to change.
5/22/2015 12:23:10 PM
Sano-radiator Technical data Sano-radiator
Technical data Height 600–1500 mm
Height H [mm]
600
750
900
1000
1100
1200
1500
Depth D [mm]
Φ ΔT 60K ΦL ΔT 50K Φ ΔT 42K Φ ΔT 30K 90/70/20°C 75/65/20°C 70/55/20°C 55/45/20°C Version [watts/el.] [watts/el.] [watts/el.] [watts/el.]
Exponent n [ ]
water Ø content Mass Surface per Standard Radiper per element water ated element element W flow rate portion M A [l/eleqms s [kg/el.] [m²/el.] ment] [kg/h el.] [%]
65
M 2060
63
50
40
26
1,31
0,83
0,10
0,61
3,8
49
105
M 3060
89
70
55
35
1,36
1,25
0,15
0,89
5,2
38
145
M 4060
114
90
72
45
1,35
1,66
0,20
1,17
6,6
33
185
M 5060
141
110
87
54
1,39
2,14
0,25
1,45
8,2
30
225
M 6060
171
133
105
64
1,41
2,58
0,29
1,74
9,7
27
65
M 2075
77
61
49
31
1,31
1,02
0,12
0,73
4,7
49
105
M 3075
109
86
68
42
1,36
1,52
0,18
1,07
6,5
38
145
M 4075
141
111
88
55
1,35
2,03
0,24
1,41
8,2
33
185
M 5075
172
135
107
66
1,39
2,59
0,30
1,75
10,1
30
225
M 6075
209
163
129
79
1,40
3,12
0,37
2,10
11,8
27
65
M 2090
91
72
58
37
1,31
1,20
0,15
0,84
5,8
49
105
M 3090
128
101
80
50
1,36
1,79
0,22
1,25
7,7
38
145
M 4090
166
131
104
65
1,35
2,39
0,29
1,65
9,6
33
185
M 5090
204
160
126
78
1,39
3,05
0,36
2,05
11,9
30
225
M 6090
247
193
152
94
1,40
3,67
0,44
2,45
14,0
27
65
M 2100
100
79
63
40
1,32
1,32
0,16
0,92
6,3
49
105
M 3100
141
111
88
55
1,36
1,98
0,24
1,37
8,4
38
145
M 4100
183
144
115
72
1,35
2,63
0,32
1,81
10,7
33
185
M 5100
224
176
139
86
1,38
3,35
0,40
2,25
13,0
30
225
M 6100
271
212
167
103
1,40
4,03
0,48
2,69
15,5
27
65
M 2110
109
87
69
44
1,32
1,44
0,18
1,00
6,9
49
105
M 3110
155
122
97
61
1,35
2,16
0,27
1,49
9,2
38
145
M 4110
199
157
125
78
1,35
2,88
0,35
1,97
11,6
33
185
M 5110
245
192
152
94
1,38
3,65
0,44
2,45
14,2
30
225
M 6110
297
232
183
113
1,40
4,40
0,53
2,93
16,9
27
65
M 2120
119
94
75
48
1,32
1,56
0,19
1,08
7,4
49
105
M 3120
167
132
105
66
1,35
2,34
0,29
1,60
10,0
38
145
M 4120
216
170
135
85
1,35
3,12
0,38
2,13
12,6
33
185
M 5120
267
209
165
102
1,38
3,96
0,48
2,65
15,4
30
225
M 6120
321
251
198
122
1,40
4,76
0,58
3,17
18,0
27
65
M 2150
148
117
94
59
1,32
1,93
0,24
1,32
9,1
49
105
M 3150
207
163
130
81
1,35
2,89
0,36
1,96
12,3
38
145
M 4150
264
208
165
104
1,35
3,85
0,48
2,60
15,5
33
185
M 5150
327
257
204
127
1,37
4,87
0,60
3,24
18,5
30
225
M 6150
393
307
242
149
1,40
5,85
0,72
3,88
21,5
27
Technical data
Heat output EN 442
For individual calculations of heat outputs, see "General Information" Length calculation: length in mm = number of elements x 65 mm - 20 mm Note extra charge for connection images.
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 11
Technology 2015-N
11
5/22/2015 12:23:10 PM
Sano-radiator Technical data Sano-radiator
Technical data Height 1800–3000 mm Heat output EN 442
Technical data
Height H [mm]
1800
2000
2200
2500
2800
3000
Depth D [mm]
Φ ΔT 60K ΦL ΔT 50K Φ ΔT 42K Φ ΔT 30K 90/70/20°C 75/65/20°C 70/55/20°C 55/45/20°C Version [watts/el.] [watts/el.] [watts/el.] [watts/el.]
Exponent n [ ]
water Ø content Mass Surface per Standard Radiper per element water ated element element W flow rate portion M A [l/eleqms s [kg/el.] [m²/el.] ment] [kg/h el.] [%]
65
M 2180
178
141
113
71
1,32
2,29
0,29
1,56
10,8
49
105
M 3180
245
193
153
96
1,35
3,43
0,43
2,32
14,6
38
145
M 4180
312
246
196
123
1,34
4,58
0,57
3,08
18,4
33
185
M 5180
388
305
242
150
1,37
5,78
0,72
3,84
22,0
30
225
M 6180
461
361
285
176
1,39
6,95
0,86
4,60
25,5
27
65
M 2200
198
157
125
79
1,32
2,53
0,32
1,72
12,0
49
105
M 3200
271
214
170
107
1,34
3,80
0,48
2,56
16,3
38
145
M 4200
342
270
215
135
1,34
5,06
0,64
3,40
20,4
33
185
M 5200
429
337
267
166
1,37
6,38
0,80
4,24
24,3
30
225
M 6200
507
397
314
194
1,39
7,67
0,95
5,08
28,4
27
65
M 2220
221
175
140
88
1,32
2,78
0,35
1,88
13,2
49
105
M 3220
298
235
187
118
1,34
4,16
0,52
2,80
17,9
38
145
M 4220
374
295
235
148
1,34
5,55
0,70
3,72
22,4
33
185
M 5220
469
369
293
183
1,36
6,99
0,87
4,64
26,5
30
225
M 6220
552
432
341
211
1,39
8,40
1,05
5,55
31,0
27
65
M 2250
254
201
161
102
1,32
3,14
0,40
2,12
15,0
49
105
M 3250
337
266
212
133
1,34
4,71
0,59
3,16
20,3
38
145
M 4250
419
331
264
166
1,34
6,27
0,79
4,19
25,4
33
185
M 5250
530
417
331
206
1,36
7,90
0,99
5,23
29,8
30
225
M 6250
617
483
382
235
1,39
9,49
1,19
6,27
37,4
27
65
M 2280
291
230
184
116
1,33
3,50
0,44
2,36
16,8
49
105
M 3280
376
297
237
149
1,34
5,25
0,67
3,51
22,5
38
145
M 4280
464
366
292
183
1,34
7,00
0,89
4,67
28,2
33
185
M 5280
591
466
371
232
1,35
8,81
1,11
5,83
33,1
30
225
M 6280
680
533
422
261
1,38
10,59
1,33
6,99
38,6
27
65
M 2300
316
250
199
126
1,33
3,75
0,48
2,51
17,9
49
105
M 3300
402
318
254
160
1,33
5,62
0,71
3,75
24,0
38
145
M 4300
494
390
311
195
1,34
7,49
0,95
4,99
30,1
33
185
M 5300
632
498
396
248
1,35
9,42
1,19
6,23
35,3
30
225
M 6300
722
566
448
277
1,38
11,31
1,43
7,46
41,3
27
For individual calculations of heat outputs, see "General Information" Length calculation: length in mm = number of elements x 65 mm - 20 mm Note extra charge for connection images.
12
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 12
Technical specifications subject to change.
5/22/2015 12:23:10 PM
Cambiotherm® Technical data Cambiotherm
Technical data Height 270–1070 mm
Height H [mm]
270
370
420
570
670
970
1070
Depth D [mm]
Φ ΔT 60K ΦL ΔT 50K Φ ΔT 42K Φ ΔT 30K 90/70/20°C 75/65/20°C 70/55/20°C 55/45/20°C Version [watts/el.] [watts/el.] [watts/el.] [watts/el.]
Exponent n [ ]
water Ø content Mass Surface per Standard Radiper per element water ated element element W flow rate portion M A [l/eleqms s [kg/el.] [m²/el.] ment] [kg/h el.] [%]
65
2027
29
23
18
12
1,30
0,43
0,04
0,34
1,6
49
105
3027
35
28
22
14
1,30
0,65
0,07
0,48
2,2
38
145
4027
44
35
28
18
1,30
0,86
0,09
0,63
2,8
33
185
5027
54
43
34
22
1,30
1,14
0,11
0,78
3,6
30
225
6027
63
50
40
26
1,30
1,37
0,13
0,95
4,2
27
65
2037
34
27
22
14
1,30
0,55
0,06
0,41
2,2
49
105
3037
48
38
30
19
1,30
0,83
0,09
0,51
3,1
38
145
4037
60
48
38
25
1,30
1,10
0,12
0,67
3,9
33
185
5037
73
58
47
30
1,30
1,44
0,15
0,83
5,1
30
225
6037
86
68
55
35
1,30
1,74
0,18
1,00
5,7
27
65
2042
39
31
25
16
1,30
0,62
0,07
0,45
2,4
49
105
3042
54
43
34
22
1,30
0,92
0,10
0,58
3,5
38
145
4042
68
54
43
28
1,30
1,23
0,13
0,76
4,5
33
185
5042
83
66
53
34
1,30
1,59
0,17
1,06
5,5
30
225
6042
98
78
63
40
1,30
1,92
0,20
1,13
6,5
27
65
2057
53
42
34
21
1,30
0,80
0,09
0,57
3,5
49
105
3057
73
58
47
30
1,30
1,19
0,14
0,78
4,8
38
145
4057
93
74
59
38
1,30
1,59
0,18
1,03
6,1
33
185
5057
113
90
72
46
1,30
2,05
0,23
1,28
7,4
30
225
6057
132
105
84
54
1,30
2,47
0,27
1,53
8,8
27
65
2067
64
51
41
26
1,30
0,92
0,10
0,61
3,8
49
105
3067
86
68
55
35
1,30
1,37
0,16
0,92
5,7
38
145
4067
108
86
69
44
1,30
1,83
0,21
1,21
7,1
33
185
5067
133
106
85
54
1,30
2,35
0,27
1,51
8,7
30
225
6067
156
124
99
63
1,30
2,83
0,32
1,80
10,4
27
65
2097
91
72
58
37
1,30
1,28
0,16
0,92
6,3
49
105
3097
124
99
79
51
1,30
1,92
0,23
1,33
8,2
38
145
4097
157
125
100
64
1,30
2,56
0,31
1,76
10,3
33
185
5097
192
153
123
78
1,30
3,26
0,40
2,25
13,0
30
225
6097
225
179
144
91
1,30
3,92
0,47
2,61
15,0
30
65
2107
99
79
63
40
1,30
1,40
0,18
1,00
6,9
49
105
3107
137
109
87
56
1,30
2,10
0,26
1,47
9,0
38
145
4107
174
138
111
70
1,30
2,80
0,34
1,94
11,4
33
185
5107
213
169
136
86
1,30
3,56
0,43
2,41
13,9
30
225
6107
249
198
159
101
1,30
4,29
0,51
2,88
16,6
27
Technical data
Heat output EN 442
For individual calculations of heat outputs, see "General Information" Length calculation: length in mm = number of elements x 45 mm Note extra charge for connection images.
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 13
Technology 2015-N
13
5/22/2015 12:23:10 PM
Standard column radiators Prices and outputs Standard column radiators
Height 180–190 mm with heat outputs depending on length and depth
Version
2019
3019
4019
5018
6018
Height H [mm]
190
190
190
180
180
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
0,33
0,50
0,66
0,89
1,08
Exponent n [ ]
1,23
1,27
1,25
1,29
1,31
Outputs
Standard heat output ΦL [Watt/element]
15
20
27
32
39
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
87 116 145 174 203
122 162 203 244 284
160 214 267 320 374
191 254 318 382 445
232 310 387 464 542
720 810 900 990 1080
16 18 20 22 24
232 261 290 319 348
325 365 406 447 487
427 481 534 587 641
509 572 636 700 763
619 697 774 851 929
1170 1260 1350 1440 1530
26 28 30 32 34
377 406 435 464 493
528 568 609 650 690
694 748 801 854 908
827 890 954 1018 1081
1006 1084 1161 1238 1316
1620 1710 1800 1890 1980
36 38 40 42 44
522 551 580 609 638
731 771 812 853 893
961 1015 1068 1121 1175
1145 1208 1272 1336 1399
1393 1471 1548 1625 1703
2070 2160 2250 2340 2430
46 48 50 52 54
667 696 725 754 783
934 974 1015 1056 1096
1228 1282 1335 1388 1442
1463 1526 1590 1654 1717
1780 1858 1935 2012 2090
2520 2610 2700
56 58 60
812 841 870
1137 1177 1218
1495 1549 1602
1781 1844 1908
2167 2245 2322
66
66
66
66
66
maximum number of elements per block
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99 For an overview of the connection versions please see connection options.
14
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 14
Technical specifications subject to change.
5/22/2015 12:23:11 PM
Standard column radiators Prices and outputs Standard column radiators
Height 260 mm
Version
2026
3026
4026
5026
6026
Height H [mm]
260
260
260
260
260
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
0,42
0,63
0,84
1,11
1,34
Exponent n [ ]
1,25
1,31
1,30
1,33
1,36
Standard heat output ΦL [Watt/element]
20
28
36
45
53
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
122 162 203 244 284
167 222 278 334 389
218 290 363 436 508
267 356 445 534 623
316 422 527 632 738
720 810 900 990 1080
16 18 20 22 24
325 365 406 447 487
445 500 556 612 667
581 653 726 799 871
712 801 890 979 1068
843 949 1054 1159 1265
1170 1260 1350 1440 1530
26 28 30 32 34
528 568 609 650 690
723 778 834 890 945
944 1016 1089 1162 1234
1157 1246 1335 1424 1513
1370 1476 1581 1686 1792
1620 1710 1800 1890 1980
36 38 40 42 44
731 771 812 853 893
1001 1056 1112 1168 1223
1307 1379 1452 1525 1597
1602 1691 1780 1869 1958
1897 2003 2108 2213 2319
2070 2160 2250 2340 2430
46 48 50 52 54
934 974 1015 1056 1096
1279 1334 1390 1446 1501
1670 1742 1815 1888 1960
2047 2136 2225 2314 2403
2424 2530 2635 2740 2846
2520 2610 2700
56 58 60
1137 1177 1218
1557 1612 1668
2033 2105 2178
2492 2581 2670
2951 3057 3162
66
66
66
66
66
maximum number of elements per block
Outputs
with heat outputs depending on length and depth
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89, 50, 70 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89, 50, 70 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 15
For an overview of the connection versions please see connection options. Technology 2015-N
15
5/22/2015 12:23:11 PM
Standard column radiators Prices and outputs Standard column radiators
Height 300 mm with heat outputs depending on length and depth
Version
2030
3030
4030
5030
6030
Height H [mm]
300
300
300
300
300
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
0,47
0,70
0,93
1,23
1,49
Exponent n [ ]
1,26
1,33
1,33
1,36
1,39
Outputs
Standard heat output ΦL [Watt/element]
24
33
43
53
62
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
143 191 239 287 335
196 262 327 392 458
256 342 427 512 598
316 422 527 632 738
372 496 620 744 868
720 810 900 990 1080
16 18 20 22 24
382 430 478 526 574
523 589 654 719 785
683 769 854 939 1025
843 949 1054 1159 1265
992 1116 1240 1364 1488
1170 1260 1350 1440 1530
26 28 30 32 34
621 669 717 765 813
850 916 981 1046 1112
1110 1196 1281 1366 1452
1370 1476 1581 1686 1792
1612 1736 1860 1984 2108
1620 1710 1800 1890 1980
36 38 40 42 44
860 908 956 1004 1052
1177 1243 1308 1373 1439
1537 1623 1708 1793 1879
1897 2003 2108 2213 2319
2232 2356 2480 2604 2728
2070 2160 2250 2340 2430
46 48 50 52 54
1099 1147 1195 1243 1291
1504 1570 1635 1700 1766
1964 2050 2135 2220 2306
2424 2530 2635 2740 2846
2852 2976 3100 3224 3348
2520 2610 2700
56 58 60
1338 1386 1434
1831 1897 1962
2391 2477 2562
2951 3057 3162
3472 3596 3720
66
66
66
66
66
maximum number of elements per block
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99 For an overview of the connection versions please see connection options.
16
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 16
Technical specifications subject to change.
5/22/2015 12:23:11 PM
Standard column radiators Prices and outputs Standard column radiators
Height 350 mm
Version
2035
3035
4035
5035
6035
Height H [mm]
350
350
350
350
350
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
0,53
0,79
1,06
1,38
1,67
Exponent n [ ]
1,31
1,36
1,35
1,39
1,41
Standard heat output ΦL [Watt/element]
28
38
49
61
72
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
166 222 277 332 388
228 304 380 456 532
296 395 494 593 692
366 488 610 732 854
429 572 715 858 1001
720 810 900 990 1080
16 18 20 22 24
443 499 554 609 665
608 684 760 836 912
790 889 988 1087 1186
976 1098 1220 1342 1464
1144 1287 1430 1573 1716
1170 1260 1350 1440 1530
26 28 30 32 34
720 776 831 886 942
988 1064 1140 1216 1292
1284 1383 1482 1581 1680
1586 1708 1830 1952 2074
1859 2002 2145 2288 2431
1620 1710 1800 1890 1980
36 38 40 42 44
997 1053 1108 1163 1219
1368 1444 1520 1596 1672
1778 1877 1976 2075 2174
2196 2318 2440 2562 2684
2574 2717 2860 3003 3146
2070 2160 2250 2340 2430
46 48 50 52 54
1274 1330 1385 1440 1496
1748 1824 1900 1976 2052
2272 2371 2470 2569 2668
2806 2928 3050 3172 3294
3289 3432 3575 3718 3861
2520 2610 2700
56 58 60
1551 1607 1662
2128 2204 2280
2766 2865 2964
3416 3538 3660
4004 4147 4290
66
66
66
66
66
maximum number of elements per block
Outputs
with heat outputs depending on length and depth
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89, 50, 70 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89, 50, 70 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 17
For an overview of the connection versions please see connection options. Technology 2015-N
17
5/22/2015 12:23:11 PM
Standard column radiators Prices and outputs Standard column radiators
Height 400 mm with heat outputs depending on length and depth
Version
2040
3040
4040
5040
6040
Height H [mm]
400
400
400
400
400
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
0,59
0,88
1,18
1,53
1,85
Exponent n [ ]
1,31
1,36
1,35
1,39
1,41
Outputs
Standard heat output ΦL [Watt/element]
31
43
56
69
81
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
188 251 314 377 440
259 345 431 517 603
335 447 559 671 783
414 552 690 828 966
485 646 808 970 1131
720 810 900 990 1080
16 18 20 22 24
502 565 628 691 754
690 776 862 948 1034
894 1006 1118 1230 1342
1104 1242 1380 1518 1656
1293 1454 1616 1778 1939
1170 1260 1350 1440 1530
26 28 30 32 34
816 879 942 1005 1068
1121 1207 1293 1379 1465
1453 1565 1677 1789 1901
1794 1932 2070 2208 2346
2101 2262 2424 2586 2747
1620 1710 1800 1890 1980
36 38 40 42 44
1130 1193 1256 1319 1382
1552 1638 1724 1810 1896
2012 2124 2236 2348 2460
2484 2622 2760 2898 3036
2909 3070 3232 3394 3555
2070 2160 2250 2340 2430
46 48 50 52 54
1444 1507 1570 1633 1696
1983 2069 2155 2241 2327
2571 2683 2795 2907 3019
3174 3312 3450 3588 3726
3717 3878 4040 4202 4363
2520 2610 2700
56 58 60
1758 1821 1884
2414 2500 2586
3130 3242 3354
3864 4002 4140
4525 4686 4848
66
66
66
66
66
maximum number of elements per block
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99 For an overview of the connection versions please see connection options.
18
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 18
Technical specifications subject to change.
5/22/2015 12:23:11 PM
Standard column radiators Prices and outputs Standard column radiators
Height 450 mm
Version
2045
3045
4045
5045
6045
Height H [mm]
450
450
450
450
450
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
0,65
0,97
1,30
1,68
2,03
Exponent n [ ]
1,31
1,36
1,35
1,39
1,41
Standard heat output ΦL [Watt/element]
35
48
62
77
90
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
210 280 350 420 490
289 386 482 578 675
374 498 623 748 872
461 615 769 923 1077
540 720 900 1080 1260
720 810 900 990 1080
16 18 20 22 24
560 630 700 770 840
771 868 964 1060 1157
997 1121 1246 1371 1495
1230 1384 1538 1692 1846
1440 1620 1800 1980 2160
1170 1260 1350 1440 1530
26 28 30 32 34
910 980 1050 1120 1190
1253 1350 1446 1542 1639
1620 1744 1869 1994 2118
1999 2153 2307 2461 2615
2340 2520 2700 2880 3060
1620 1710 1800 1890 1980
36 38 40 42 44
1260 1330 1400 1470 1540
1735 1832 1928 2024 2121
2243 2367 2492 2617 2741
2768 2922 3076 3230 3384
3240 3420 3600 3780 3960
2070 2160 2250 2340 2430
46 48 50 52 54
1610 1680 1750 1820 1890
2217 2314 2410 2506 2603
2866 2990 3115 3240 3364
3537 3691 3845 3999 4153
4140 4320 4500 4680 4860
2520 2610 2700
56 58 60
1960 2030 2100
2699 2796 2892
3489 3613 3738
4306 4460 4614
5040 5220 5400
66
66
66
66
66
maximum number of elements per block
Outputs
with heat outputs depending on length and depth
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89, 50, 70 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89, 50, 70 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 19
For an overview of the connection versions please see connection options. Technology 2015-N
19
5/22/2015 12:23:12 PM
Standard column radiators Prices and outputs Standard column radiators
Height 500 mm with heat outputs depending on length and depth
Version
2050
3050
4050
5050
6050
Height H [mm]
500
500
500
500
500
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
0,71
1,06
1,42
1,83
2,21
Exponent n [ ]
1,31
1,36
1,35
1,39
1,41
Outputs
Standard heat output ΦL [Watt/element]
39
53
69
85
99
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
232 309 386 463 540
319 426 532 638 745
412 549 686 823 960
509 678 848 1018 1187
595 793 991 1189 1387
720 810 900 990 1080
16 18 20 22 24
618 695 772 849 926
851 958 1064 1170 1277
1098 1235 1372 1509 1646
1357 1526 1696 1866 2035
1586 1784 1982 2180 2378
1170 1260 1350 1440 1530
26 28 30 32 34
1004 1081 1158 1235 1312
1383 1490 1596 1702 1809
1784 1921 2058 2195 2332
2205 2374 2544 2714 2883
2577 2775 2973 3171 3369
1620 1710 1800 1890 1980
36 38 40 42 44
1390 1467 1544 1621 1698
1915 2022 2128 2234 2341
2470 2607 2744 2881 3018
3053 3222 3392 3562 3731
3568 3766 3964 4162 4360
2070 2160 2250 2340 2430
46 48 50 52 54
1776 1853 1930 2007 2084
2447 2554 2660 2766 2873
3156 3293 3430 3567 3704
3901 4070 4240 4410 4579
4559 4757 4955 5153 5351
2520 2610 2700
56 58 60
2162 2239 2316
2979 3086 3192
3842 3979 4116
4749 4918 5088
5550 5748 5946
66
66
66
66
66
maximum number of elements per block
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99 For an overview of the connection versions please see connection options.
20
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 20
Technical specifications subject to change.
5/22/2015 12:23:12 PM
Standard column radiators Prices and outputs Standard column radiators
Height 550 mm
Version
2055
3055
4055
5055
6055
Height H [mm]
550
550
550
550
550
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
0,77
1,16
1,54
1,99
2,40
Exponent n [ ]
1,31
1,36
1,35
1,39
1,41
Standard heat output ΦL [Watt/element]
42
58
75
93
108
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
253 338 422 506 591
350 466 583 700 816
449 599 749 899 1049
555 740 925 1110 1295
648 864 1080 1296 1512
720 810 900 990 1080
16 18 20 22 24
675 760 844 928 1013
933 1049 1166 1283 1399
1198 1348 1498 1648 1798
1480 1665 1850 2035 2220
1728 1944 2160 2376 2592
1170 1260 1350 1440 1530
26 28 30 32 34
1097 1182 1266 1350 1435
1516 1632 1749 1866 1982
1947 2097 2247 2397 2547
2405 2590 2775 2960 3145
2808 3024 3240 3456 3672
1620 1710 1800 1890 1980
36 38 40 42 44
1519 1604 1688 1772 1857
2099 2215 2332 2449 2565
2696 2846 2996 3146 3296
3330 3515 3700 3885 4070
3888 4104 4320 4536 4752
2070 2160 2250 2340 2430
46 48 50 52 54
1941 2026 2110 2194 2279
2682 2798 2915 3032 3148
3445 3595 3745 3895 4045
4255 4440 4625 4810 4995
4968 5184 5400 5616 5832
2520 2610 2700
56 58 60
2363 2448 2532
3265 3381 3498
4194 4344 4494
5180 5365 5550
6048 6264 6480
66
66
66
66
66
maximum number of elements per block
Outputs
with heat outputs depending on length and depth
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89, 50, 70 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89, 50, 70 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 21
For an overview of the connection versions please see connection options. Technology 2015-N
21
5/22/2015 12:23:12 PM
Standard column radiators Prices and outputs Standard column radiators
Height 600 mm with heat outputs depending on length and depth
Version
2060
3060
4060
5060
6060
Height H [mm]
600
600
600
600
600
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
0,83
1,25
1,66
2,14
2,58
Exponent n [ ]
1,31
1,36
1,35
1,39
1,41
Outputs
Standard heat output ΦL [Watt/element]
46
63
81
100
117
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
275 366 458 550 641
379 506 632 758 885
487 649 811 973 1135
600 800 1000 1200 1400
702 936 1170 1404 1638
720 810 900 990 1080
16 18 20 22 24
733 824 916 1008 1099
1011 1138 1264 1390 1517
1298 1460 1622 1784 1946
1600 1800 2000 2200 2400
1872 2106 2340 2574 2808
1170 1260 1350 1440 1530
26 28 30 32 34
1191 1282 1374 1466 1557
1643 1770 1896 2022 2149
2109 2271 2433 2595 2757
2600 2800 3000 3200 3400
3042 3276 3510 3744 3978
1620 1710 1800 1890 1980
36 38 40 42 44
1649 1740 1832 1924 2015
2275 2402 2528 2654 2781
2920 3082 3244 3406 3568
3600 3800 4000 4200 4400
4212 4446 4680 4914 5148
2070 2160 2250 2340 2430
46 48 50 52 54
2107 2198 2290 2382 2473
2907 3034 3160 3286 3413
3731 3893 4055 4217 4379
4600 4800 5000 5200 5400
5382 5616 5850 6084 6318
2520 2610 2700
56 58 60
2565 2656 2748
3539 3666 3792
4542 4704 4866
5600 5800 6000
6552 6786 7020
66
66
66
66
66
maximum number of elements per block
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99 For an overview of the connection versions please see connection options.
22
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 22
Technical specifications subject to change.
5/22/2015 12:23:12 PM
Standard column radiators Prices and outputs Standard column radiators
Height 750 mm
Version
2075
3075
4075
5075
6075
Height H [mm]
750
750
750
750
750
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
1,02
1,52
2,03
2,59
3,12
Exponent n [ ]
1,31
1,36
1,35
1,39
1,40
Standard heat output ΦL [Watt/element]
57
78
100
123
143
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
339 452 565 678 791
467 623 779 935 1091
597 796 995 1194 1393
738 984 1230 1476 1722
858 1144 1430 1716 2002
720 810 900 990 1080
16 18 20 22 24
904 1017 1130 1243 1356
1246 1402 1558 1714 1870
1592 1791 1990 2189 2388
1968 2214 2460 2706 2952
2288 2574 2860 3146 3432
1170 1260 1350 1440 1530
26 28 30 32 34
1469 1582 1695 1808 1921
2025 2181 2337 2493 2649
2587 2786 2985 3184 3383
3198 3444 3690 3936 4182
3718 4004 4290 4576 4862
1620 1710 1800 1890 1980
36 38 40 42 44
2034 2147 2260 2373 2486
2804 2960 3116 3272 3428
3582 3781 3980 4179 4378
4428 4674 4920 5166 5412
5148 5434 5720 6006 6292
2070 2160 2250 2340 2430
46 48 50 52 54
2599 2712 2825 2938 3051
3583 3739 3895 4051 4207
4577 4776 4975 5174 5373
5658 5904 6150 6396 6642
6578 6864 7150 7436 7722
2520 2610 2700
56 58 60
3164 3277 3390
4362 4518 4674
5572 5771 5970
6888 7134 7380
8008 8294 8580
66
66
66
66
66
maximum number of elements per block
Outputs
with heat outputs depending on length and depth
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89, 50, 70 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89, 50, 70 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 23
For an overview of the connection versions please see connection options. Technology 2015-N
23
5/22/2015 12:23:12 PM
Standard column radiators Prices and outputs Standard column radiators
Height 900 mm with heat outputs depending on length and depth
Version
2090
3090
4090
5090
6090
Height H [mm]
900
900
900
900
900
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
1,20
1,79
2,39
3,05
3,67
Exponent n [ ]
1,31
1,36
1,35
1,39
1,40
Outputs
Standard heat output ΦL [Watt/element]
67
92
117
144
168
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
402 536 670 804 938
554 738 923 1108 1292
702 936 1170 1404 1638
864 1152 1440 1728 2016
1008 1344 1680 2016 2352
720 810 900 990 1080
16 18 20 22 24
1072 1206 1340 1474 1608
1477 1661 1846 2031 2215
1872 2106 2340 2574 2808
2304 2592 2880 3168 3456
2688 3024 3360 3696 4032
1170 1260 1350 1440 1530
26 28 30 32 34
1742 1876 2010 2144 2278
2400 2584 2769 2954 3138
3042 3276 3510 3744 3978
3744 4032 4320 4608 4896
4368 4704 5040 5376 5712
1620 1710 1800 1890 1980
36 38 40 42 44
2412 2546 2680 2814 2948
3323 3507 3692 3877 4061
4212 4446 4680 4914 5148
5184 5472 5760 6048 6336
6048 6384 6720 7056 7392
2070 2160 2250 2340 2430
46 48 50 52 54
3082 3216 3350 3484 3618
4246 4430 4615 4800 4984
5382 5616 5850 6084 6318
6624 6912 7200 7488 7776
7728 8064 8400 8736 9072
2520 2610 2700
56 58 60
3752 3886 4020
5169 5353 5538
6552 6786 7020
8064 8352 8640
9408 9744 10080
66
66
66
66
66
maximum number of elements per block
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99 For an overview of the connection versions please see connection options.
24
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 24
Technical specifications subject to change.
5/22/2015 12:23:12 PM
Standard column radiators Prices and outputs Standard column radiators
Height 1000 mm
Version
2100
3100
4100
5100
6100
Height H [mm]
1000
1000
1000
1000
1000
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
1,32
1,98
2,63
3,35
4,03
Exponent n [ ]
1,32
1,36
1,35
1,38
1,40
Standard heat output ΦL [Watt/element]
74
102
129
158
185
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
444 592 740 888 1036
612 816 1020 1224 1428
774 1032 1290 1548 1806
948 1264 1580 1896 2212
1110 1480 1850 2220 2590
720 810 900 990 1080
16 18 20 22 24
1184 1332 1480 1628 1776
1632 1836 2040 2244 2448
2064 2322 2580 2838 3096
2528 2844 3160 3476 3792
2960 3330 3700 4070 4440
1170 1260 1350 1440 1530
26 28 30 32 34
1924 2072 2220 2368 2516
2652 2856 3060 3264 3468
3354 3612 3870 4128 4386
4108 4424 4740 5056 5372
4810 5180 5550 5920 6290
1620 1710 1800 1890 1980
36 38 40 42 44
2664 2812 2960 3108 3256
3672 3876 4080 4284 4488
4644 4902 5160 5418 5676
5688 6004 6320 6636 6952
6660 7030 7400 7770 8140
2070 2160 2250 2340 2430
46 48 50 52 54
3404 3552 3700 3848 3996
4692 4896 5100 5304 5508
5934 6192 6450 6708 6966
7268 7584 7900 8216 8532
8510 8880 9250 9620 9990
2520 2610 2700
56 58 60
4144 4292 4440
5712 5916 6120
7224 7482 7740
8848 9164 9480
10360 10730 11100
66
66
66
66
58
maximum number of elements per block
Outputs
with heat outputs depending on length and depth
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89, 50, 70 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89, 50, 70 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 25
For an overview of the connection versions please see connection options. Technology 2015-N
25
5/22/2015 12:23:13 PM
Standard column radiators Prices and outputs Standard column radiators
Height 1100 mm with heat outputs depending on length and depth
Version
2110
3110
4110
5110
6110
Height H [mm]
1100
1100
1100
1100
1100
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
1,44
2,16
2,88
3,65
4,40
Exponent n [ ]
1,32
1,35
1,35
1,38
1,40
Outputs
Standard heat output ΦL [Watt/element]
81
111
141
172
201
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
486 648 810 972 1134
666 888 1110 1332 1554
846 1128 1410 1692 1974
1032 1376 1720 2064 2408
1206 1608 2010 2412 2814
720 810 900 990 1080
16 18 20 22 24
1296 1458 1620 1782 1944
1776 1998 2220 2442 2664
2256 2538 2820 3102 3384
2752 3096 3440 3784 4128
3216 3618 4020 4422 4824
1170 1260 1350 1440 1530
26 28 30 32 34
2106 2268 2430 2592 2754
2886 3108 3330 3552 3774
3666 3948 4230 4512 4794
4472 4816 5160 5504 5848
5226 5628 6030 6432 6834
1620 1710 1800 1890 1980
36 38 40 42 44
2916 3078 3240 3402 3564
3996 4218 4440 4662 4884
5076 5358 5640 5922 6204
6192 6536 6880 7224 7568
7236 7638 8040 8442 8844
2070 2160 2250 2340 2430
46 48 50 52 54
3726 3888 4050 4212 4374
5106 5328 5550 5772 5994
6486 6768 7050 7332 7614
2520 2610 2700
56 58 60
4536 4698 4860
6216 6438 6660
7896 8178 8460
66
66
66
44
44
maximum number of elements per block
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99 For an overview of the connection versions please see connection options.
26
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 26
Technical specifications subject to change.
5/22/2015 12:23:13 PM
Standard column radiators Prices and outputs Standard column radiators
Height 1200 mm
Version
2120
3120
4120
5120
6120
Height H [mm]
1200
1200
1200
1200
1200
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
1,56
2,34
3,12
3,96
4,76
Exponent n [ ]
1,32
1,35
1,35
1,38
1,40
Standard heat output ΦL [Watt/element]
88
120
152
186
217
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
528 704 880 1056 1232
720 960 1200 1440 1680
912 1216 1520 1824 2128
1116 1488 1860 2232 2604
1302 1736 2170 2604 3038
720 810 900 990 1080
16 18 20 22 24
1408 1584 1760 1936 2112
1920 2160 2400 2640 2880
2432 2736 3040 3344 3648
2976 3348 3720 4092 4464
3472 3906 4340 4774 5208
1170 1260 1350 1440 1530
26 28 30 32 34
2288 2464 2640 2816 2992
3120 3360 3600 3840 4080
3952 4256 4560 4864 5168
4836 5208 5580 5952 6324
5642 6076 6510 6944 7378
1620 1710 1800 1890 1980
36 38 40 42 44
3168 3344 3520 3696 3872
4320 4560 4800 5040 5280
5472 5776 6080 6384 6688
6696 7068 7440 7812 8184
7812 8246 8680 9114 9548
2070 2160 2250 2340 2430
46 48 50 52 54
4048 4224 4400 4576 4752
5520 5760 6000 6240 6480
6992 7296 7600 7904 8208
2520 2610 2700
56 58 60
4928 5104 5280
6720 6960 7200
8512 8816 9120
66
66
66
44
44
maximum number of elements per block
Outputs
with heat outputs depending on length and depth
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89, 50, 70 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89, 50, 70 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 27
For an overview of the connection versions please see connection options. Technology 2015-N
27
5/22/2015 12:23:13 PM
Standard column radiators Prices and outputs Standard column radiators
Height 1500 mm with heat outputs depending on length and depth
Version
2150
3150
4150
5150
6150
Height H [mm]
1500
1500
1500
1500
1500
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
1,93
2,89
3,85
4,87
5,85
Exponent n [ ]
1,32
1,35
1,35
1,37
1,40
Outputs
Standard heat output ΦL [Watt/element]
109
147
186
225
264
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
654 872 1090 1308 1526
882 1176 1470 1764 2058
1116 1488 1860 2232 2604
1350 1800 2250 2700 3150
1584 2112 2640 3168 3696
720 810 900 990 1080
16 18 20 22 24
1744 1962 2180 2398 2616
2352 2646 2940 3234 3528
2976 3348 3720 4092 4464
3600 4050 4500 4950 5400
4224 4752 5280 5808 6336
1170 1260 1350 1440 1530
26 28 30 32 34
2834 3052 3270 3488 3706
3822 4116 4410 4704 4998
4836 5208 5580 5952 6324
5850 6300 6750
6864 7392 7920
1620 1710 1800 1890 1980
36 38 40 42 44
3924 4142 4360 4578 4796
5292 5586 5880 6174 6468
6696 7068 7440 7812 8184
2070 2160 2250 2340 2430
46 48 50 52 54
5014 5232 5450 5668 5886
6762 7056 7350 7644 7938
8556 8928 9300 9672 10044
2520 2610 2700
56 58 60
6104 6322 6540
8232 8526 8820
10416 10788 11160
66
66
54
30
30
maximum number of elements per block
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99 For an overview of the connection versions please see connection options.
28
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 28
Technical specifications subject to change.
5/22/2015 12:23:13 PM
Standard column radiators Prices and outputs Standard column radiators
Height 1800 mm
Version
2180
3180
4180
5180
6180
Height H [mm]
1800
1800
1800
1800
1800
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
2,29
3,43
4,58
5,78
6,95
Exponent n [ ]
1,32
1,35
1,34
1,37
1,39
Standard heat output ΦL [Watt/element]
130
173
219
263
309
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
780 1040 1300 1560 1820
1038 1384 1730 2076 2422
1314 1752 2190 2628 3066
1578 2104 2630 3156 3682
1854 2472 3090 3708 4326
720 810 900 990 1080
16 18 20 22 24
2080 2340 2600 2860 3120
2768 3114 3460 3806 4152
3504 3942 4380 4818 5256
4208 4734 5260 5786 6312
4944 5562 6180 6798 7416
1170 1260 1350 1440 1530
26 28 30 32 34
3380 3640 3900 4160 4420
4498 4844 5190 5536 5882
5694 6132 6570 7008 7446
6838 7364 7890
8034 8652 9270
1620 1710 1800 1890 1980
36 38 40 42 44
4680 4940 5200 5460 5720
6228 6574 6920 7266 7612
7884 8322 8760 9198 9636
2070 2160 2250 2340 2430
46 48 50 52 54
5980 6240 6500 6760 7020
7958 8304 8650 8996 9342
10074 10512 10950 11388 11826
2520 2610 2700
56 58 60
7280 7540 7800
9688 10034 10380
12264 12702 13140
66
66
54
30
30
maximum number of elements per block
Outputs
with heat outputs depending on length and depth
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89, 50, 70 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89, 50, 70 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 29
For an overview of the connection versions please see connection options. Technology 2015-N
29
5/22/2015 12:23:13 PM
Standard column radiators Prices and outputs Standard column radiators
Height 2000 mm with heat outputs depending on length and depth
Version
2200
3200
4200
5200
6200
Height H [mm]
2000
2000
2000
2000
2000
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
2,53
3,80
5,06
6,38
7,67
Exponent n [ ]
1,32
1,34
1,34
1,37
1,39
Outputs
Standard heat output ΦL [Watt/element]
144
190
241
287
339
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
864 1152 1440 1728 2016
1140 1520 1900 2280 2660
1446 1928 2410 2892 3374
1722 2296 2870 3444 4018
2034 2712 3390 4068 4746
720 810 900 990 1080
16 18 20 22 24
2304 2592 2880 3168 3456
3040 3420 3800 4180 4560
3856 4338 4820 5302 5784
4592 5166 5740 6314 6888
5424 6102 6780 7458 8136
1170 1260 1350 1440 1530
26 28 30 32 34
3744 4032 4320 4608 4896
4940 5320 5700 6080 6460
6266 6748 7230 7712 8194
7462 8036 8610
8814 9492 10170
1620 1710 1800 1890 1980
36 38 40 42 44
5184 5472 5760 6048 6336
6840 7220 7600 7980 8360
8676 9158 9640 10122 10604
2070 2160 2250 2340 2430
46 48 50 52 54
6624 6912 7200 7488 7776
8740 9120 9500 9880 10260
11086 11568 12050 12532 13014
2520 2610 2700
56 58 60
8064 8352 8640
10640 11020 11400
13496 13978 14460
66
59
44
30
30
maximum number of elements per block
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99 For an overview of the connection versions please see connection options.
30
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 30
Technical specifications subject to change.
5/22/2015 12:23:14 PM
Standard column radiators Prices and outputs Standard column radiators
Height 2200 mm
Version
2220
3220
4220
5220
6220
Height H [mm]
2200
2200
2200
2200
2200
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
2,78
4,16
5,55
6,99
8,40
Exponent n [ ]
1,32
1,34
1,34
1,36
1,39
Standard heat output ΦL [Watt/element]
158
207
262
310
367
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
948 1264 1580 1896 2212
1242 1656 2070 2484 2898
1572 2096 2620 3144 3668
1860 2480 3100 3720 4340
2202 2936 3670 4404 5138
720 810 900 990 1080
16 18 20 22 24
2528 2844 3160 3476 3792
3312 3726 4140 4554 4968
4192 4716 5240 5764 6288
4960 5580 6200 6820 7440
5872 6606 7340 8074 8808
1170 1260 1350 1440 1530
26 28 30 32 34
4108 4424 4740 5056 5372
5382 5796 6210 6624 7038
6812 7336 7860 8384 8908
8060 8680 9300
9542 10276 11010
1620 1710 1800 1890 1980
36 38 40 42 44
5688 6004 6320 6636 6952
7452 7866 8280 8694 9108
9432 9956 10480 11004 11528
2070 2160 2250 2340 2430
46 48 50 52 54
7268 7584 7900 8216 8532
9522 9936 10350 10764 11178
12052 12576 13100 13624 14148
2520 2610 2700
56 58 60
8848 9164 9480
11592 12006 12420
14672 15196 15720
42
59
44
30
22
maximum number of elements per block
Outputs
with heat outputs depending on length and depth
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89, 50, 70 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89, 50, 70 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 31
For an overview of the connection versions please see connection options. Technology 2015-N
31
5/22/2015 12:23:14 PM
Standard column radiators Prices and outputs Standard column radiators
Height 2500 mm with heat outputs depending on length and depth
Version
2250
3250
4250
5250
6250
Height H [mm]
2500
2500
2500
2500
2500
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
3,14
4,71
6,27
7,90
9,49
Exponent n [ ]
1,32
1,34
1,34
1,36
1,39
Outputs
Standard heat output ΦL [Watt/element]
179
231
293
343
408
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
1074 1432 1790 2148 2506
1386 1848 2310 2772 3234
1758 2344 2930 3516 4102
2058 2744 3430 4116 4802
2448 3264 4080 4896 5712
720 810 900 990 1080
16 18 20 22 24
2864 3222 3580 3938 4296
3696 4158 4620 5082 5544
4688 5274 5860 6446 7032
5488 6174 6860 7546 8232
6528 7344 8160 8976 9792
1170 1260 1350 1440 1530
26 28 30 32 34
4654 5012 5370 5728 6086
6006 6468 6930
7618 8204 8790
8918 9604 10290
10608 11424 12240
1620 1710 1800 1890 1980
36 38 40 42 44
6444 6802 7160 7518 7876
2070 2160 2250 2340 2430
46 48 50 52 54
8234 8592 8950 9308 9666
2520 2610 2700
56 58 60
10024 10382 10740 30
30
30
22
maximum number of elements per block
42
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99 For an overview of the connection versions please see connection options.
32
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 32
Technical specifications subject to change.
5/22/2015 12:23:14 PM
Standard column radiators Prices and outputs Standard column radiators
Height 2800 mm
Version
2280
3280
4280
5280
6280
Height H [mm]
2800
2800
2800
2800
2800
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
3,50
5,25
7,00
8,81
10,59
Exponent n [ ]
1,33
1,34
1,34
1,35
1,38
Standard heat output ΦL [Watt/element]
200
255
323
374
448
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
1200 1600 2000 2400 2800
1530 2040 2550 3060 3570
1938 2584 3230 3876 4522
2244 2992 3740 4488 5236
2688 3584 4480 5376 6272
720 810 900 990 1080
16 18 20 22 24
3200 3600 4000 4400 4800
4080 4590 5100 5610 6120
5168 5814 6460 7106 7752
5984 6732 7480 8228 8976
7168 8064 8960 9856 10752
1170 1260 1350 1440 1530
26 28 30 32 34
5200 5600 6000 6400 6800
6630 7140 7650
8398 9044 9690
9724 10472 11220
11648 12544 13440
1620 1710 1800 1890 1980
36 38 40 42 44
7200 7600 8000 8400 8800
2070 2160 2250 2340 2430
46 48 50 52 54
9200 9600 10000 10400 10800
2520 2610 2700
56 58 60
11200 11600 12000 30
30
26
22
maximum number of elements per block
42
Outputs
with heat outputs depending on length and depth
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89, 50, 70 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89, 50, 70 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99
Technical specifications subject to change.
Buch_020_Roehrenradiator_128_ex.indb 33
For an overview of the connection versions please see connection options. Technology 2015-N
33
5/22/2015 12:23:14 PM
Standard column radiators Prices and outputs Standard column radiators
Height 3000 mm with heat outputs depending on length and depth
Version
2300
3300
4300
5300
6300
Height H [mm]
3000
3000
3000
3000
3000
Depth T [mm]
65
105
145
185
225
Ø Mass per element M [kg/element]
3,75
5,62
7,49
9,42
11,31
Exponent n [ ]
1,33
1,33
1,34
1,35
1,38
Outputs
Standard heat output ΦL [Watt/element]
214
270
343
394
474
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
ΦS ΔT 50K [watts]
Length L [mm]
Length [el.]
ΦS ΔT 50K [watts]
270 360 450 540 630
6 8 10 12 14
1284 1712 2140 2568 2996
1620 2160 2700 3240 3780
2058 2744 3430 4116 4802
2364 3152 3940 4728 5516
2844 3792 4740 5688 6636
720 810 900 990 1080
16 18 20 22 24
3424 3852 4280 4708 5136
4320 4860 5400 5940 6480
5488 6174 6860 7546 8232
6304 7092 7880 8668 9456
7584 8532 9480 10428 11376
1170 1260 1350 1440 1530
26 28 30 32 34
5564 5992 6420 6848 7276
7020 7560 8100
8918 9604 10290
10244 11032 11820
12324 13272 14220
1620 1710 1800 1890 1980
36 38 40 42 44
7704 8132 8560 8988 9416
2070 2160 2250 2340 2430
46 48 50 52 54
9844 10272 10700 11128 11556
2520 2610 2700
56 58 60
11984 12412 12840 30
30
26
22
maximum number of elements per block
42
Mass per radiator > 125 kg (empty weight) Standard heat output ΦL and ΦS at 75 / 65 / 20 °C (ΔT 50K) acc. to EN 442 The radiators are delivered in 2 or 3 parts as per the maximum number of elements. These can be fitted together on-site (on site BG) or at factory (at factory at an additional charge). Connection without built-in valve Connection with built-in valve Con- 12, 34, 14 and 32 Valve side top connection arrangement - 69, 89 nection - 24, 42, 2 and 4 Valve side top connection arrangement - 96, 98 arrange- 13, 31, 23, 41, 6 and 8 Valve side bottom connection arrangement - 69, 89 ment - 68, 86, 58, 76, 69, 89, 50 and 70 Valve side bottom connection arrangement - 96, 98 - 57, 75, 67, 85 and 99 For an overview of the connection versions please see connection options.
34
Technology 2015-N
Buch_020_Roehrenradiator_128_ex.indb 34
Technical specifications subject to change.
5/22/2015 12:23:14 PM