beko part2

Page 1

LG Air Conditioners 2011


Tropical Multi V III

If you need a highly efficient air conditioning system in your building, VRS is the right choice for you. Wall Mounted

2Way Casstte

Tropical Multi V Mini

4Way Casstte

1Way Casstte

High Static

Tropical Multi V Water II

Low Static

Ceiling & Floor

Floor Standing - With Case

Multi V series Indoor unit

Ceiling Suspended

Floor Standing - Without Case

eco V V-Net & Accessory



Tropical Multi V III Tropical Multi V Mini

Low Noise Super light BLDC motor guarantees your enhanced comfortable indoor environment.

Office

Conversation

Library

4 way CST

Tropical Multi V Water II

Typing

4 Vanes Independent Operation

All vane operation

Air flow rate control

Multi V series Indoor unit

Vane angle control satisfies both users who like direct wind and indirect wind. and also it prevents cold air draft.

Individual vane operation

Direct air flow

Indirect air flow Individual vane angle control

eco V

Auto Elevation Grille Easy filter cleaning with elevation grille - Installed inside main body - Auto horizontal level - 4 points support - Memory for user’s level - Max. 4.5m length Memory for user’s level

Auto bottom detection

STOP Memory *Available for 24k ~ 48k Btu/h

Max. 4.5m

Auto horizontal control

Conventional 3.5m

V-Net & Accessory

4-Point support structure

New Cassette 4.5m


Wide Jet Vane Improved wide and narrow vane will provide comfortable temperature distribution without air flow dead zone.

• Air flow improvement

80mm Wider!!

567mm

NEW Current

487mm

Highlander Even air distribution

Temp. 27°C

15°C

Current

Air flow dead zone

Temp. 27°C

15°C

High Ceiling Mode High ceiling mode with phase-control algorithm is possible to apply as high as 3.6m of ceiling. Conventional

4 way CST


Tropical Multi V III Tropical Multi V Mini

Flexible Connection Flexible connection of remote controller

• Easy & solid attachment to the wall

Tropical Multi V Water II

- Group control : 1 remote controller to several indoor units - Second remote control : 2 remote controllers to 1 indoor unit

Multi V series Indoor unit

Application of Ceiling Concealed Duct It is possible to make each rooms cool & warm with installing a chamber and a spiral duct.

eco V

Max. 9 discharging

V-Net & Accessory


Linear E.S.P Control Air volume and sound are always kept as design regardless of E.S.P change using this technology , you can • Optimize duct work Installation • Keep capacity & sound level as desired • Simplify model numbers The phase control motor technology offers money saving benefit to the installer. *E.S.P is easily controlled by remote controller

Compact Size The indoor unit with slim and compact size has reduced the restriction which enables successful installation in various spaces.

6.0 ~ 7.2 kW 8.3 ~ 11.0 kW conventional LG 218mm

288mm

204mm 246mm


Tropical Multi V III Tropical Multi V Mini

One Touch Type Panel It provides easy installation with a one-touch detachable panel.

Tropical Multi V Water II

Convenient Installation • Coner detachable design

Refrigerant piping check

Hanger adjust

Drain leakage check

Drain leakage check

Multi V series Indoor unit

Easy installation with corner detachable decoration panel.

Hanger adjust

Hanger adjust eco V V-Net & Accessory


Easy Drain Installation It reduces the installation time by over 40% with elbow-less drain hose.

Drain hose

Drain pump

Midget drain pump covers maximum 800mm high, featuring easy piping installation. * Accessory (Drain hose) PHDHA05T – 500mm 30EA PHDHA07T - 700mm 30EA

PHDHA05B – 500mm 5EA PHDHA07B – 700mm 5EA

3Way Flexible Installation All sides (front, back, floor) are possible to install and connect to the outdoor unit.

Back

Side

Floor

Sliding Type Filter All sides (front, back, floor) are possible to install and connect to the outdoor unit. Anti-biotic filter

Sliding type

Easy cleaning


Tropical Multi V III Tropical Multi V Mini

Neo Plasma Air Purifying System Unique NEO Plasma air purifying system is equipped with 7 specialized filters in 5 separate stages to enhance its cleaning power. It reduces fine dust and mold, unpleasant odors and cigarette smoke as air passes through each filter.

Clean Air

03 Bio Fusion Filter

The antibacterial pre-filter primarily reduces large dust, mold and quilt dust.

Bio fusion filters allow their Bio enzymes to directly penetrate through cell walls of some bacteria and allergen to decompose its cell nuclei.

02 Triple Filter

04 Plasma Filter

The triple filter consists of three specialized filters to reduce the symptoms associated with various organic compounds including formaldehyde. It also has the ability to reduce unpleasant odors creating a more comfortable environment.

The PLASMA Air Purifying System developed uniquely and not only reduces microscopic contaminants and dust, but also reduces house mites, pollen, and pet fur to reduce allergy and asthma symptoms.

eco V

01 Pre Filter

Multi V series Indoor unit

Odor Free! Dust Free! Allergy Free!

Tropical Multi V Water II

Polluted Air

V-Net & Accessory


Digital Air Flow Control The air flow can be controlled to ensure maximum comfort and convenience.

Normal

fast & even widely

Jet cool

speedy & powerful

Sleep mode

indirectly & softly

Swirl Swing Swirl swing distributes air evenly throughout the room to ensure a more comfortable conditioned environment by adjusting the movement of the vane.

• Comparison of temperatures

Swirl swing (plaesant air)

Normal air flow

Vertical Temp. differences

Horizontal Temp. differences

Healthy Dehumidification Dehumidification mode reduces uncomfortable humidity from the room without over cooling.

Indoor Temperature Distribution Chart Healthy By increasing the vane angle, a better approach of the actual temperature is possible to prevent over cooling.

Conventional Since the surrounding temperature is measured after the air from the unit is widely distributed, accurate approach of the air is not possible.


Tropical Multi V III Tropical Multi V Mini

Comfort Air Flow

Cooling

Heating (Nomal)

Heating (Floor Heating Mode)

1st Advanced pre filter : The antibacterial pre-filter primarily reduces large dust, mould and quilt dust.

3rd Plazma Inon Generator

V-Net & Accessory

3rd Plazma Inon Generator : The sterilized ion generating system, Ion Generator, emits around 1.2 million ions, and catches hazardous substances floating in the air, therefore proactively looking for and catching germs.

2nd Allergy Filter

eco V

2nd Allergy Filter : Filter consists of enzyme that breaks down allergen, apatite, andorganic/inorganic binder that attaches the enzyme to the filter. When the air passes the filter, allergen clings to the filter and like tiny pairs of scissors the enzymes cut allergen's protein to deactivate the allergen.

1st Advanced pre filter

Multi V series Indoor unit

Healthy Air (3 stage air filter system)

Tropical Multi V Water II

Different air flow of cooling & heating For cooling, the vane is adjusted upwards to let the cold air travel up. As for heating, the vane sends the heated air downwards to balance room temperature specially for floor.


Auto Clean Auto clean helps to remove odor and save clean-up time. After using airconditioner, “Auto clean” makes the inner part of Air conditioner dry for 30 min. It removes mositure and mold so you can enjoy odor-free air and save time to clean up.

Auto Clean

Conventional

1 STEP Dries the evaporator with gentle low noise air from the fan by removing any remaining moisture. Pressing the Auto Clean button will activate the automatic cleaning function after the cooling operation.

2 STEP Removes moulds through the neo plasma system. Only the fan will operate to dry the inner part of the air conditioner in just 30 minutes.

Air Flow Direction Control ow control Adjust the horizontal airflow direction by manually moving the horizontal airflow direction vane by hand. ow The airflow direction can be adjusted as desired by using the remote controller.

• Horizontal airflow control

• Vertical airflow control


Tropical Multi V III Tropical Multi V Mini

Weekly Program The operator can set an on/off reservation of the air conditioner for a period of one week. SUNDAY MONDAY

• On/Off • Test run mode • Self-diagnosis • 3-step fan speed selection • Operation indication • Room temperature

TUESDAY WEDNESDAY THURSDAY FRIDAY

Tropical Multi V Water II

LCD Wired Remote Controller

SATURDAY

Multi V series Indoor unit

Accessory Wired Remote Controller

Deluxe Type

Standard Type

Standard Type

Standard Type

Simple Type

Simple Type for Hotel

PQRCUDS0-X

PQRCVSL0-X

PQRCVSL0QW-X

PZRCUSB0-X

PQRCVCL0QW-X PQRCVCL0Q-X

PQRCHCA0QW-X PQRCHCA0Q-X

eco V

Wireless remote controller

V-Net & Accessory

PQWRH(C)DF0-X


WALL MOUNTED BTNI07GGSEP-X BTNI09GGSEP-X BTNI12GGSEP-X BTNI15GGSEP-X BTNI18GS5P-X BTNI24GS5P-X

Specifications Model Capacity

Unit Cooling

kW Btu/h

Heating

kW Btu/h

BTNI07GGSEP-X

BTNI09GGSEP-X

BTNI12GGSEP-X

BTNI15GGSEP-X

BTNI18GS5P-X

2.2

2.8

3.6

4.5

5.6

7.1

7,500

9,600

12,300

15,400

19,100

24,200

BTNI24GS5P-X

2.5

3.2

4.0

5.0

6.3

8.0

8,500

10,900

13,600

17,100

21,500

27,300 40

Power

Cooling

W

40

40

40

40

40

Input

Heating

W

40

40

40

40

40

40

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

895x165x282

895x165x282

895x165x282

895x165x282

1090x178x300

1090x178x300

9

9

9

9

12

12

dBA±3

37 / 33 / 23

39 / 35 / 25

41 / 36 / 27

42 / 36 / 27

44 / 40 / 36

46 / 41 / 38

CMM

5.6 / 5 / 4.6

7 / 6.5 / 6

9.5 / 9 / 8.5

10.5 / 9 / 8.5

12 / 10.5 / 9

14 / 13 / 10

Power Supply

Ø, V, Hz

Dimensions(WxDxH)

mm

Weight

kg

Noise level Air flow rate

H/M/L

Neo Plasma air purifying filter Piping

Liquid

mm(inch)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø9.52(3/8)

Connection

Gas

mm(inch)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø15.88(5/8)

20/16

20/16

20/16

20/16

20/16

20/16

BTNI15GGSEP-X

BTNI18GS5P-X

BTNI24GS5P-X

Drain(OD/ID)

mm

Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification

* Accessories BTNI07GGSEP-X

Model Dry Contact

Without case(1 contact point)

BTNI09GGSEP-X

BTNI12GGSEP-X

PQDSA

With case(1 contact point)

PQDSB/ PQDSB1

With case(2 contact point)

PQDSBC


4 WAY CASSETTE (570*570) BTNI05GTRP-X BTNI07GTRP-X BTNI09GTRP-X BTNI12GTRP-X BTNI15GTQC-X BTNI18GTQC-X

Specifications Model Capacity

Unit Cooling

kW Btu/h

Heating

kW Btu/h

BTNI05GTRP-X

BTNI07GTRP-X

BTNI09GTRP-X

BTNI12GTRP-X

BTNI15GTQC-X

1.6

2.2

2.8

3.6

4.5

5.6

5,500

7,500

9,600

12,300

15,400

19,100

BTNI18GTQC-X

1.8

2.5

3.2

4.0

5.0

6.3

6,100

8,500

10,900

13,600

17,100

21,500 30

Power

Cooling

W

30

30

30

30

30

Input

Heating

W

30

30

30

30

30

30

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

Power Supply

Ø, V, Hz

Dimensions

Body

mm

570x570x214

570x570x214

570x570x214

570x570x214

570x570x256

570x570x256

(WxDxH)

Front panel

mm

700x700x30

700x700x30

700x700x30

700x700x30

700x700x30

700x700x30

Weight

Body

kg

13.1

13.1

14.2

14.2

15.5

15.5

Front panel

3.2

3.2

3.2

3.2

3.2

3.2

Morning Fog

Morning Fog

Morning Fog

Morning Fog

Morning Fog

Morning Fog

dBA±3

29 / 27 / 26

29 / 27 / 26

30 / 29 / 27

32 / 30 / 27

36 / 34 / 32

37 / 35 / 34

CMM

7.5 / 7 / 6.6

7.5 / 7 / 6.6

8 / 7.5 / 7.1

8.7 / 8 / 7

11 / 10 / 9.3

11.2 / 11 / 10

Panel Color Noise level Air flow rate

H/M/L

Neo Plasma air purifying filter Drain Pump Piping

Liquid

mm(inch)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Connection

Gas

mm(inch)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

32/25

32/25

32/25

32/25

32/25

32/25

BTNI15GTQC-X

BTNI18GTQC-X

Drain(OD/ID)

mm

Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification

* Accessories BTNI05GTRP-X

Model Dry Contact

Front Panel

Without case(1 contact point)

BTNI07GTRP-X

BTNI09GTRP-X

BTNI12GTRP-X

PQDSA

With case(1 contact point)

PQDSB/ PQDSB1

With case(2 contact point)

PQDSBC PT-UQC


Tropical Multi V Mini

BTNI24GTPP-X BTNI28GTPP-X BTNI36GTNP-X BTNI42GTMP-X BTNI48GTMP-X

Capacity

Unit Cooling

kW Btu/h

Heating

kW Btu/h

BTNI24GTPP-X

BTNI28GTPP-X

BTNI36GTNP-X

BTNI42GTMP-X

7.1

8.2

10.6

12.3

14.1

24,200

28,000

36,200

42,000

48,100

BTNI48GTMP-X

8.0

9.2

11.9

13.8

15.9

27,300

31,500

40,600

43,800

51,200 144

Cooling

W

33

33

144

144

Input

Heating

W

33

33

144

144

144

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

Power Supply

Ø, V, Hz

Dimensions

Body

mm

840x840x204

840x840x204

840x840x246

840x840x288

840x840x288

(WxDxH)

Front panel

mm

950x950x25

950x950x25

950x950x25

950x950x25

950x950x25

Weight

Body

kg

20.8

20.8

23.5

25.6

25.6

Front panel

5.6

5.6

5.6

5.6

5.6

Morning Fog

Morning Fog

Morning Fog

Morning Fog

Morning Fog

dBA±3

36 / 34 / 31

39 / 35 / 33

43 / 40 / 37

44 / 41 / 38

46 / 43 / 41

CMM

17 / 15 / 13

19 / 16 / 14

25 / 21 / 19

30 / 27 / 24

31 / 29 / 27

Panel Color Noise level Air flow rate

H/M/L

Neo Plasma air purifying filter

Multi V series Indoor unit

Power

Tropical Multi V Water II

Specifications Model

Tropical Multi V III

4 WAY CASSETTE (840*840)

Drain Pump Piping

Liquid

mm(inch)

Ø9.52(3/8)

Ø9.52(3/8)

Ø9.52(3/8)

Ø9.52(3/8)

Ø9.52(3/8)

Connection

Gas

mm(inch)

Ø15.88(5/8)

Ø15.88(5/8)

Ø15.88(5/8)

Ø15.88(5/8)

Ø15.88(5/8)

32/25

32/25

32/25

32/25

32/25

BTNI28GTPP-X

BTNI36GTNP-X

BTNI42GTMP-X

BTNI48GTMP-X

Drain(OD/ID)

mm

eco V

Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification

* Accessories Dry Contact

Without case(1 contact point)

PQDSA

With case(1 contact point)

PQDSB/ PQDSB1

With case(2 contact point)

PQDSBC

Front Panel

PT-UMC

Auto Elevation Grille

PTEGM0

Ventilation Kit

PTVK410 / PTVK420 / PTVK 430

V-Net & Accessory

BTNI24GTPP-X

Model


2 WAY CASSETTE

BTNI18GTLP-X BTNI24GTLP-X

Specifications Model Capacity

Unit Cooling

BTNI18GTLP-X kW Btu/h

Heating

kW Btu/h

BTNI24GTLP-X

5.6

7.1

19,100

24,200

6.3

8.0

21,500

27,300 70

Power

Cooling

W

70

Input

Heating

W

70

70

1, 220~240, 50

1, 220~240, 50

Power Supply

Ø, V, Hz

Dimensions

Body

mm

830x550x225

830x550x225

(WxDxH)

Front panel

mm

1,050x640x28.5

1,050x640x28.5

Weight

Body

kg

22

22

Front panel

4.5

4.5

Morning Fog

Morning Fog

dBA±3

40 / 36 / 32

42 / 38 / 34

CMM

13 / 12 / 10

17 / 15 / 13

Panel Color Noise level Air flow rate

H/M/L

Neo Plasma air purifying filter Drain Pump Piping

Liquid

mm(inch)

Ø6.35(1/4)

Ø9.52(3/8)

Connection

Gas

mm(inch)

Ø12.7(1/2)

Ø15.88(5/8)

32/25

32/25

Drain(OD/ID)

mm

Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification

* Accessories BTNI18GTLP-X

Model Dry Contact

Front Panel

Without case(1 contact point)

BTNI24GTLP-X PQDSA

With case(1 contact point)

PQDSB/ PQDSB1

With case(2 contact point)

PQDSBC PT-HLC


BTNI07GTUP-X BTNI09GTUP-X BTNI12GTUP-X BTNI18GTTP-X BTNI24GTTP-X

Grill Type

Tropical Multi V Mini

Moving Panel Type

Capacity

Unit Cooling

kW Btu/h

Heating

kW Btu/h

BTNI07GTUP-X

BTNI09GTUP-X

BTNI12GTUP-X

BTNI18GTTP-X

2.2

2.8

3.6

5.6

7.1

7,500

9,600

12,300

19,100

24,200

BTNI24GTTP-X

2.5

3.2

4.0

6.3

7.1

8,500

10,900

13,600

21,500

24,200 70

Cooling

W

40

40

40

70

Input

Heating

W

40

40

40

70

70

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

Power Supply

Ø, V, Hz

Dimensions

Body

mm

860x450x132

860x450x132

860x450x132

1,180x450x132

1,180x450x132

(WxDxH)

Front panel

mm

1,100x500x34

1,100x500x34

1,100x500x34

1,420x500x34

1,420x500x34

Weight

Body

14.7

14.7

14.7

18.7

18.7

5.3/4.4

5.3/4.4

5.3/4.4

6.5/5.5

6.5/5.5

kg

Front panel(Panel/Grille) Panel Color Noise level Air flow rate

dBA±3 H/M/L

CMM

White

White

White

White

White

32 / 29 / 25

35 / 34 / 32

38 / 35 / 32

40 / 37 / 35

43 / 40 / 36

8.2 / 7.3 / 6.4

9.2 / 8.6 / 8.2

10 / 9.2 / 8.2

14.6 / 12.1 / 10.9

14.6 / 13.3 / 11.5

Neo Plasma air purifying filter

Multi V series Indoor unit

Power

Tropical Multi V Water II

Specifications Model

Tropical Multi V III

1 WAY CASSETTE

Drain Pump Piping

Liquid

mm(inch)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø9.52(3/8)

Connection

Gas

mm(inch)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø15.88(5/8)

32/25

32/25

32/25

32/25

32/25

BTNI09GTUP-X

BTNI12GTUP-X

BTNI18GTTP-X

Drain(OD/ID)

mm

eco V

Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification

* Accessories Dry Contact

Front Panel

BTNI24GTTP-X

PQDSA

PQDSA

With case(1 contact point)

PQDSB/ PQDSB1

PQDSB/ PQDSB1

With case(2 contact point)

PQDSBC

PQDSBC

Grill Type

PT-UUC

PT-UUC

Moving Panel Type

PT-UUD

PT-UUD

Without case(1 contact point)

V-Net & Accessory

BTNI07GTUP-X

Model


LOW STATIC DUCT BTNI07GB1S-X BTNI09GB1S-X BTNI12GB1S-X BTNI15GB1S-X BTNI18GB2S-X BTNI24GB2S-X

Specifications Model Capacity

Unit Cooling

kW Btu/h

Heating

kW Btu/h

BTNI07GB1S-X

BTNI09GB1S-X

BTNI12GB1S-X

BTNI15GB1S-X

BTNI18GB2S-X

2.2

2.8

3.6

4.5

5.6

7.1

7,500

9,600

12,300

15,400

19,100

24,200

BTNI24GB2S-X

2.5

3.2

4.0

5.0

6.3

8.0

8,500

10,900

13,600

17,100

21,500

27,300 80

Power

Cooling

W

30

30

30

30

80

Input

Heating

W

30

30

30

30

80

80

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

820x575x190

820x575x190

820x575x190

820x575x190

1,100x575x190

1,100x575x190

21

21

21

21

26

26

29 / 26 / 24

31 / 29 / 26

33 / 30 / 29

34 / 33 / 31

40 / 37 / 34

43 / 40 / 37

Power Supply

Ø, V, Hz

Dimensions(WxDxH)

mm

Weight

kg

Noise level

dBA±3

E.S.P range Air flow rate

H/M/L

mmAq

0~4

0~4

0~4

0~4

0~4

0~4

CMM

8.5 / 7.5 / 6.5

9.5 / 8.5 / 7.5

10.5 / 9.5 / 8.5

11.5 / 10.5 / 9.5

16 / 14 / 12

19 / 17 / 15

-

-

-

-

-

-

Liquid

mm(inch)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø9.52(3/8)

Gas

mm(inch)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø15.88(5/8)

32/25.4

32/25.4

32/25.4

32/25.4

32/25.4

32/25.4

BTNI15GB1S-X

BTNI18GB2S-X

BTNI24GB2S-X

Neo Plasma air purifying filter Piping Connection

Drain(OD/ID)

mm

Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification

* Accessories BTNI07GB1S-X

Model Dry Contact

Without case(1 contact point)

BTNI09GB1S-X

BTNI12GB1S-X

PQDSA

With case(1 contact point)

PQDSB/ PQDSB1

With case(2 contact point)

PQDSBC


HIGH STATIC DUCT BTNI07GBHS-X BTNI09GBHS-X BTNI12GBHS-X BTNI15GBHS-X BTNI18GBHS-X BTNI24GBHS-X

Specifications Model Capacity

Unit Cooling

kW Btu/h

Heating

kW Btu/h

BTNI07GBHS-X

BTNI09GBHS-X

BTNI12GBHS-X

BTNI15GBHS-X

BTNI18GBHS-X

2.2

2.8

3.6

4.5

5.6

7.1

7,500

9,600

12,300

15,400

19,100

24,200

BTNI24GBHS-X

2.5

3.2

4.0

5.0

6.3

8.0

8,500

10,900

13,600

17,100

21,500

27,300 150

Power

Cooling

W

150

150

150

150

150

Input

Heating

W

150

150

150

150

150

150

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

882x450x260

882x450x260

882x450x260

882x450x260

882x450x260

882x450x260

26

26

26

26

26.5

26.5

34 / 33 / 32

35 / 34 / 33

37 / 35 / 34

39 / 38 / 37

42.5 / 41 / 37

45 / 43 / 41

8.5 / 7.5 / 6

10 / 8.5 / 7.5

12 / 10 / 8.5

13.5 / 12 / 8.5

15.5 / 13.5 / 12.4

18.3 / 16.9 / 15.5

-

-

-

-

-

-

Power Supply

Ø, V, Hz

Dimensions(WxDxH)

mm

Weight

kg

Noise level

dBA±3

E.S.P range Air flow rate

mmAq H/M/L

CMM

Neo Plasma air purifying filter Piping Connection

Liquid

mm(inch)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø9.52(3/8)

Gas

mm(inch)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø15.88(5/8)

32/25

32/25

32/25

32/25

32/25

32/25

BTNI15GBHS-X

BTNI18GBHS-X

BTNI24GBHS-X

Drain(OD/ID)

mm

Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification

* Accessories BTNI07GBHS-X

Model Dry Contact

Without case(1 contact point)

BTNI09GBHS-X

BTNI12GBHS-X

PQDSA

With case(1 contact point)

PQDSB/ PQDSB1

With case(2 contact point)

PQDSBC


Tropical Multi V Mini

BTNI28GBGS-X BTNI36GBGS-X BTNI42GBGS-X BTNI48GBRS-X URNU76GB8S-X URNU96GB8S-X

Capacity

Unit Cooling

kW Btu/h

Heating

kW Btu/h

BTNI28GBGS-X

BTNI36GBGS-X

BTNI42GBGS-X

BTNI48GBRS-X

URNU76GB8S-X

8.2

10.6

12.3

14.1

22.4

28.0

28,000

36,200

42,000

48,100

76,400

95,900

URNU96GB8S-X

9.2

11.9

13.8

15.9

25.2

31.5

31,500

40,600

43,800

51,200

86,000

107,500 800

Cooling

W

450

450

450

450

800

Input

Heating

W

450

450

450

450

800

800

Ø, V, Hz

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

mm

1,182x450x298

1,182x450x298

1,182x450x298

1,230x590x380

1,562x688x460

1,562x688x460

38

38

38

53

87

87

44 / 42 / 40

46 / 44 / 42

48 / 46 / 45

45 / 43 / 41

50 / 48 / 48

52 / 50 / 50 76 / 64 / 64

Power Supply Dimensions(WxDxH) Weight

kg

Noise level

dBA±3

E.S.P range Air flow rate

H/M/L

mmAq

6~16

6~14

6~12

7~20

CMM

25.9 / 24.1 / 21.8

32.3 / 29 / 25.3

34.5 / 32.3 / 30.7

44.8 / 40.6 / 33.3

64 / 50 / 50

-

-

-

-

-

-

Neo Plasma air purifying filter Piping Connection

Liquid

mm(inch)

Ø9.52(3/8)

Ø9.52(3/8)

Ø9.52(3/8)

Ø9.52(3/8)

Ø9.52(3/8)

Ø9.52(3/8)

Gas

mm(inch)

Ø15.88(5/8)

Ø15.88(5/8)

Ø15.88(5/8)

Ø15.88(5/8)

Ø19.05(3/4)

Ø22.2(7/8)

32/25

32/25

32/25

32/25

32/25

32/25

BTNI48GBRS-X

URNU76GB8S-X

URNU96GB8S-X

Drain(OD/ID)

mm

eco V

Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification

Multi V series Indoor unit

Power

Tropical Multi V Water II

Specifications Model

Tropical Multi V III

HIGH STATIC DUCT

* Accessories Dry Contact

Without case(1 contact point)

BTNI36GBGS-X

BTNI42GBGS-X

PQDSA

With case(1 contact point)

PQDSB/ PQDSB1

With case(2 contact point)

PQDSBC

V-Net & Accessory

BTNI28GBGS-X

Model


CEILING & FLOOR

BTNI09GVES-X BTNI12GVES-X

Specifications Model Capacity

Unit Cooling

BTNI09GVES-X kW Btu/h

Heating

kW Btu/h

BTNI12GVES-X

2.8

3.6

9,600

12,300

3.2

4.0

10,900

13,600 30

Power

Cooling

W

30

Input

Heating

W

30

30

1, 220~240, 50

1, 220~240, 50

900x200x490

900x200x490

Power Supply

Ø, V, Hz

Dimensions(WxDxH)

mm

13.7

13.7

dBA±3

36 / 32 / 28

38 / 36 / 30

CMM

7.6 / 6.9 / 6.2

9.2 / 7.6 / 6.9

Weight

kg

Noise level Air flow rate

H/M/L

Plasma air purifying filter Piping Connection

-

-

Liquid

mm(inch)

Ø6.35(1/4)

Ø6.35(1/4)

Gas

mm(inch)

Ø12.7(1/2)

Ø12.7(1/2)

20/16

20/16

Drain(OD/ID)

mm

Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification

* Accessories BTNI09GVES-X

Model Dry Contact

Without case(1 contact point)

BTNI12GVES-X PQDSA

With case(1 contact point)

PQDSB/ PQDSB1

With case(2 contact point)

PQDSBC


Tropical Multi V Mini

URNU18GVJS-X URNU24GVJS-X URNU48GVLS-X

Model

Unit Cooling

kW Btu/h

Heating

kW Btu/h

URNU18GVJS-X

URNU24GVJS-X

5.6

7.1

14.1

19,100

24,200

48100

URNU48GVLS-X

6.3

8.0

15.9

21,500

27,300

51200 63

Cooling

W

63

63

Input

Heating

W

63

63

63

1, 220~240, 50

1, 220~240, 50

1, 220 ~ 240, 50

950x220x650

950x220x650

1750x650x220

24.6

24.6

45

dBA±3

42 / 40 / 37

43 / 41 / 39

49/48/47

CMM

16 / 14 / 12

18 / 16 / 14

35/32/30

-

-

-

Power Supply

Ø, V, Hz

Dimensions(WxDxH)

mm

Weight

kg

Noise level Air flow rate

H/M/L

Plasma air purifying filter Piping Connection

Liquid

mm(inch)

Ø6.35(1/4)

Ø9.52(3/8)

Ø9.52(3/8)

Gas

mm(inch)

Ø12.7(1/2)

Ø15.88(5/8)

Ø15.88(5/8)

20/16

20/16

16(5/8)

BTNI24GVJS-X

URNU48GVLS-X

Drain(OD/ID)

mm

eco V

Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification

Multi V series Indoor unit

Power

Tropical Multi V Water II

Specifications Capacity

Tropical Multi V III

CEILING SUSPENDED

* Accessories Dry Contact

Without case(1 contact point)

PQDSA

With case(1 contact point)

PQDSB/ PQDSB1

With case(2 contact point)

PQDSBC

V-Net & Accessory

BTNI18GVJS-X

Model


FLOOR STANDING WITH CASE BTNI07GCES-X BTNI09GCES-X BTNI12GCES-X BTNI15GCES-X BTNI18GCFS-X BTNI24GCFS-X

Specifications Model Capacity

Unit Cooling

kW Btu/h

Heating

kW Btu/h

BTNI07GCES-X

BTNI09GCES-X

BTNI12GCES-X

BTNI15GCES-X

BTNI18GCFS-X

2.2

2.8

3.6

4.5

5.6

7.1

7,500

9,600

12,300

15,400

19,100

24,200

BTNI24GCFS-X

2.5

3.2

4.0

5.0

6.3

8.0

8,500

10,900

13,600

17,100

21,500

27,300 80

Power

Cooling

W

30

30

30

30

80

Input

Heating

W

30

30

30

30

80

80

Ø, V, Hz

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

mm

1,067x203x635

1,067x203x635

1,067x203x635

1,067x203x635

1,345x203x635

1,345x203x635

27

27

27

27

34

34

dBA±3

35 / 33 / 31

36 / 34 / 32

37 / 35 / 33

38 / 37 / 25

40 / 37 / 34

43 / 40 / 37

CMM

8.5 / 7.5 / 6.5

9.5 / 8.5 / 7.5

10.5 / 9.5 / 8.5

11.5 / 10 / 9.5

16 / 14 / 12

18 / 16 / 14

-

-

-

-

-

-

Power Supply Dimensions(WxDxH) Weight

kg

Noise level Air flow rate

H/M/L

Plasma air purifying filter Piping Connection

Liquid

mm(inch)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø9.52(3/8)

Gas

mm(inch)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø15.88(5/8)

12

12

12

12

12

12

BTNI15GCES-X

BTNI18GCFS-X

BTNI24GCFS-X

Drain(OD/ID)

mm

Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification

* Accessories BTNI07GCES-X

Model Dry Contact

Without case(1 contact point)

BTNI09GCES-X

BTNI12GCES-X

PQDSA

With case(1 contact point)

PQDSB/ PQDSB1

With case(2 contact point)

PQDSBC


Tropical Multi V Mini

BTNI07GCEUS-X BTNI09GCEUS-X BTNI12GCEUS-X BTNI15GCEUS-X BTNI18GCFUS-X BTNI24GCFUS-X

Model

Unit Cooling

kW Btu/h

Heating

kW Btu/h

BTNI07GCEUS-X

BTNI09GCEUS-X

BTNI12GCEUS-X

BTNI15GCEUS-X

BTNI18GCFUS-X

2.2

2.8

3.6

4.5

5.6

BTNI24GCFUS-X 7.1

7,500

9,600

12,300

15,400

19,100

24,200

2.5

3.2

4.0

5.0

6.3

8.0

8,500

10,900

13,600

17,100

21,500

27,300 80

Cooling

W

30

30

30

30

80

Input

Heating

W

30

30

30

30

80

80

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

1, 220~240, 50

978x190x639

978x190x639

978x190x639

978x190x639

1,256x190x639

1,256x190x639

20

20

20

20

27

27

dBA±3

35 / 33 / 31

36 / 34 / 32

37 / 35 / 33

38 / 37 / 35

40 / 37 / 34

43 / 40 / 37

CMM

8.5 / 7.5 / 6.5

9.5 / 8.5 / 7.5

10.5 / 9.5 / 8.5

11.5 / 10 / 9.5

16 / 14 / 12

18 / 16 / 14

-

-

-

-

-

-

Power Supply

Ø, V, Hz

Dimensions(WxDxH)

mm

Weight

kg

Noise level Air flow rate

H/M/L

Plasma air purifying filter Piping Connection

Liquid

mm(inch)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø6.35(1/4)

Ø9.52(3/8)

Gas

mm(inch)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø15.88(5/8)

12

12

12

12

12

12

BTNI15GCEUS-X

BTNI18GCFUS-X

BTNI24GCFUS-X

Drain(OD/ID)

mm

eco V

Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification

Multi V series Indoor unit

Power

Tropical Multi V Water II

Specifications Capacity

Tropical Multi V III

FLOOR STANDING WITHOUT CASE

* Accessories Dry Contact

BTNI07GCEUS-X

Without case(1 contact point)

BTNI09GCEUS-X

BTNI12GCEUS-X

PQDSA

With case(1 contact point)

PQDSB/ PQDSB1

With case(2 contact point)

PQDSBC

V-Net & Accessory

Model


Tropical Multi V III

Tropical Multi V Mini

Tropical Multi V Water II

Multi V series Indoor unit

eco V

V-Net & Accessory


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.