Simpson Strong-Tie Connector Guide 2016

Page 34

Concrete Connectors & Anchors

Concrete Connectors & Anchors

SB Anchor Bolt SB Bolts at Stemwall: Garage Front Dimensions (in.) Model No.

Stemwall Width

Allowable Tension Loads

Dia.

Length

Min. Embed. (le)

Wind & SDC A&B

Code Ref.

SDC C-F

Step-Down End

Corner

Step-Down End

Corner

SB7⁄8 x24

8

7

⁄8

24

18

7225

7660

6070

6435

SB1x30

8

1

30

24

11305

9635

9495

8030

I23

13⁄4"

Length

Corner

Step-down end

8"

4" min (SB7⁄8) 3" min (SB1)

111⁄4" max

le

Stemwall Garage Front

Perspective View

8"

4" min (SB7⁄8) 3" min (SB1)

16" min (SB7⁄8) 12" min (SB1)

Plan View

SB Bolts at Slab on Grade: Edge Dimensions (in.) Model No.

Footing Width

Allowable Tension Loads

Dia.

Length

Min. Embed. (le)

Wind & SDC A&B Midwall

Corner

Code Ref.

SDC C-F Midwall

Corner

SB ⁄8 x24

12

5

⁄8

24

18

6675

6675

6675

5730

SB7⁄8 x24

12

7

⁄8

24

18

13080

12135

12320

10190

SB1x30

12

1

30

24

17080

15580

16300

13090

5

Midwall Corner

111⁄4" max.

Slab 4"

Corner

11⁄2"

13⁄4"

Slab not shown for clarity

4" min (SB5⁄8 and 7⁄8) 3" min (SB1)

12"

Slab Edge

Perspective View

12"

Midwall

Cold Joint

1.5 le

Two-Pour Installation

Plan View

SB Bolts at Slab on Grade: Garage Curb Dimensions (in.) Model No.

Curb Width

Allowable Tension Loads

Dia.

Length

Min. Embed. (le)

Wind & SDC A&B Step-down End

Corner

Step-down End

SB7⁄8 x24

6

7

⁄8

24

18

9175

11075

7705

9305

SB1x30

6

1

30

24

15580

15580

13090

13090

Step-down end

1¾"

Length

le

111⁄4" max.

11⁄2"

Corner I23

Slab not shown for clarity

Corner

6"

Plan View

12"

Slab Garage Curb

Notes to the Designer:

34

Code Ref.

SDC C-F

Perspective View

4" min (SB7⁄8) 3" min (SB1)

16" min (SB7⁄8) 12" min (SB1)

4" min (SB7⁄8) 3" min (SB1)

1. Rebar is required at top of stemwall foundations but is not required for Slab-on-Grade Edge and Garage Curb, or Stemwall Garage Front installations. 2. Minimum end distances for SB bolts are as shown in graphics. 3. Multiply the tabulated ASD wind or seismic loads by 1.6 or 1.4, respectively, to obtain LRFD capacities. 4. Per Section 1613 of the IBC, detached one- and two-story dwellings in SDC C may use “Wind and SDC A&B” allowable loads. 5. See ESR-2611 for additional information. 6. Midwall loads apply when anchor is 1.5 le or greater from the end. For bolts acting in tension simultaneously, the minimum bolt center-to-center spacing is 3 le. 7. Full catalog loads apply for two-pour installation for slab-on-grade: edge.

C-C-2015 © 2015 SIMPSON STRONG-TIE COMPANY INC. PRINTED 12/14

Length

13⁄4"

le

I23