OPEN FRONT BOOTH • HEAVY DUTY CONSTRUCTION • BATCH AND AUTOMATED PRODUCTION DESIGNS • EASY TO INSTALL • ETL CERTIFICATION AVAILABLE EXHAUST SYSTEM FEATURES A tubeaxial exhaust fan designed specifically for use in paint spray booths powers the airflow, through the booth and exhaust stack. All exhaust fans are of non-sparking construction.The motor drive and bearings are sealed from the air stream of the exhaust. Motors are provided with each unit.

•Control panel and other electric components can be purchased separately •ETL Listed when optional control panel is added

•Industry-leading light levels •Spray booth specific, dual voltage T-8 32-watt light fixtures

•Air solenoid valve

•Constructed from 18 gauge, prime-quality steel •All panels and support members are precision punched for easy nut and bolt assembly •5/16” bolt with self locking nuts

OVERVIEW The Open Front Booth is designed for both batch type and conveyorized production systems. Air flow is drawn in through the open front, across the work area and exhausted through a filter bank in the back of the booth. The dry arrestor filters trap the airborne overspray particles before the filtered air is discharged through the exhaust system and into the atmosphere. The booths are available in a wide range of designs to meet practically any production requirement. Conveyor pass-through openings can be as much as 25% of the booth open front area, without requiring additional exhaust fan capacity. Specially engineered enclosures may be designed to meet your requirements. Air replacement units and intake chambers can be added as well as reduced air flows for automatic spray operations.

LIGHTING FEATURES Lighted booths provide a bright, full booth illumination from four-tube, 48" long, 32-watt, fluorescent light fixtures. All fixtures are UL listed and approved for their intended use and placement. The light tubes are furnished with Class I Division II sealed and gasketed fixtures.


Industrial

Auto

Wood

OPEN FRONT BOOTH Model Interior Dimensions Number Width Height Length IB-04-07-05 4’-0" 7’-0" 5’-0" IB-06-07-05 6’-0" 7'-0" 5’-0" IB-08-07-05 8’-0" 7'-0" 5’-0" IB-10-07-05 10’-0" 7'-0" 5’-0" IB-12-07-07 12’-0" 7'-0" 7’-0" IB-14-07-07 14’-0" 7'-0" 7’-0" IB-16-07-07 16’-0" 7'-0" 7’-0" IB-18-07-07 18’-0" 7'-0" 7’-0" IB-20-07-07 20’-0" 7’-0" 7’-0"

Exterior Dimensions Width Height Length 4’-4” 7’-2” 7’-2” 6’-4” 7’-2” 7’-8” 8’-4” 7’-2” 7’-8” 10’-4” 7’-2” 8’-2” 12’-4” 7’-2” 10’-2” 15’-0” 7’-6” 10’-8” 17’-0” 7’-6” 10’-8” 19’-0” 7’-6” 11’-8” 21’-0” 7’-6” 11’-8”

IB-04-08-05 4’-0" 8’-0" IB-06-08-05 6’-0" 8’-0" IB-08-08-05 8’-0" 8’-0" IB-10-08-05 10’-0" 8’-0" IB-12-08-07 12'-0" 8’-0" IB-14-08-07 14’-0" 8’-0" IB-16-08-07 16’-0" 8’-0" IB-18-08-07 18’-0" 8’-0" IB-20-08-07 20’-0" 8’-0"

5’-0" 5’-0" 5’-0" 5’-0" 7’-0" 7’-0" 7’-0" 7’-0" 7’-0"

4’-4” 6’-4” 8’-4” 10’-4” 12’-4” 15’-0” 17’-0” 19’-0” 21’-0”

8’-2” 8’-2” 8’-2” 8’-2” 8’-2” 8’-6” 8’-6” 8’-6” 8’-6”

IB-04-10-05 4’-0" 10’-0" IB-06-10-05 6’-0" 10’-0" IB-08-10-05 8’-0" 10’-0" IB-10-10-05 10’-0" 10’-0" IB-12-10-07 12’-0" 10’-0" IB-14-10-07 4’-0" 10’-0" IB-16-10-07 16’-0" 10’-0" IB-18-10-07 18’-0" 10’-0" IB-20-10-07 20’-0" 10’-0"

5’-0" 5’-0" 5’-0" 5’-0" 7’-0" 7’-0" 7’-0" 7’-0" 7’-0"

4’-4” 6’-4” 8’-4” 10’-4” 12’-4” 15’-0” 17’-0” 19’-0” 21’-0”

IB-04-12-05 4’-0" 12’-0" IB-06-12-05 6’-0" 12’-0" IB-08-12-05 8’-0" 12’-0" IB-10-12-05 10’-0" 12’-0" IB-12-12-07 12’-0" 12’-0" IB-14-12-07 14’-0" 12’-0" IB-16-12-07 16’-0" 12’-0" IB-18-12-07 18’-0" 12’-0" IB-20-12-07 20’-0" 12’-0"

5’-0" 5’-0" 5’-0" 5’-0" 7’-0" 7’-0" 7’-0" 7’-0" 7’-0"

4’-4” 6’-4” 8’-4” 10’-4” 12’-4” 15’-0” 17’-0” 19’-0” 21’-0”

Ref. Key

A

B

C

Qty. Lights 0 1 1 2 2 2 2 3 4

Qty. Filters 8 12 16 20 24 32 36 40 44

7’-2” 7’-8” 7’-8” 8’-2” 10’-2” 10’-8” 11’-8” 11’-8” 11’-8”

0 1 1 2 2 2 2 3 4

8 12 16 20 24 32 36 40 44

18” 24” 24” 30” 30” 30” 36” 36” 42”

10’-2” 10’-2” 10’-2” 10’-2” 10’-2” 10’-6” 10’-6” 10’-6” 10’-6”

7’-2” 7’-8” 8’-2” 8’-2” 10’-2” 11’-8” 11’-8” 11’-8” 11’-8”

0 1 1 2 2 2 2 3 4

10 15 20 25 30 40 45 50 55

12’-2” 12’-2” 12’-2” 12’-2” 12’-2” 12’-6” 12’-6” 12’-6” 12’-6”

7’-8” 7’-8” 8’-2” 8’-2” 11’-2” 11’-8” 11’-8” 11’-8” 11’-8”

0 1 1 2 2 2 2 3 4

12 18 24 30 36 48 54 60 66

D

Fan Fan Diameter HP 18” .75HP 24” 1HP 24” 2HP 30” 2HP 30” 3HP 30” 3HP 30” 5HP 36” 5HP 36” 5HP

SCFM @ 1/2” SP 3,500 5,250 7,150 8,750 10,500 12,250 14,000 15,750 17,500

Shipping Weight 675 940 1,240 1,630 1,870 2,450 2,650 3,000 3,540

.75HP 1.5HP 2HP 3HP 3HP 5HP 5HP 5HP 5HP

4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000

703 1,020 1,490 1,780 2,270 2,600 2,810 3,150 3,690

18” 24” 30” 30” 30” 36” 42” 42” 42”

1.5HP 2HP 2HP 3HP 5HP 5HP 5HP 5HP 7.5HP

5,000 7,500 10,000 12,500 15,000 17,500 20,000 22,500 25,000

1,100 1,650 1,900 2,350 2,500 3,000 3,400 4,000 4,400

24” 24” 30” 30” 36” 42” 42” 42” 42”

1.5HP 3HP 3HP 5HP 5HP 5HP 7.5HP 7.5HP 10HP

6,000 9,000 12,000 15,000 18,000 21,000 24,000 27,000 30,000

975 1,500 1,700 2,200 2,500 3,200 3,500 4,100 4,700

Col-Met Spray Booths - Rockwall, TX // e-mail: sales@colmetsb.com - Toll-free: 888.452.6684 // www.colmetsb.com COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Auto

Wood

OPEN FRONT BENCH BOOTH • HEAVY DUTY CONSTRUCTION • BATCH AND AUTOMATED PRODUCTION DESIGNS • EASY TO INSTALL EXHAUST SYSTEM FEATURES

A tubeaxial exhaust fan designed specifically for use in paint spray booths powers the airflow through the booth and exhaust stack. All exhaust fans are of non-sparking construction. The motor drive and bearings are sealed from the air stream of the exhaust. Motors are provided with each unit.

•Control panel and other electric components can be purchased separately •ETL Listed when optional control panel is added

•Industry-leading light levels •Spray booth specific, dual voltage T-8 32-watt light fixtures

•Air solenoid valve

•Constructed from 18 gauge, prime-quality steel •All panels and support members are precision punched for easy nut and bolt assembly •5/16” bolt with self locking nuts

OVERVIEW

The Open Front Bench Booth is designed for both batch type and conveyorized production systems. Air flow is drawn in through the open front, across the painter and parts being coated and exhausted through a filter bank in the back of the booth. The dry arrestor filters trap the airborne overspray particles before the filtered air is discharged through the exhaust system and into the atmosphere. The booths are available in a wide range of designs to meet practically any production requirement. Conveyor pass through openings can be as much as 25% of the booth open front area, without requiring additional exhaust fan capacity. Specially engineered enclosures may be designed to meet your requirements. Air replacement units and intake chambers can be added as well as reduced air flows for automatic spray operations.

LIGHTING FEATURES

Lighted booths provide a bright, full booth illumination from four-tube, 48" long, 32-watt, fluorescent light fixtures. Each is Class I, Division II, sealed and gasketed construction. All fixtures are UL listed and approved for their intended use and placement. The light tubes are furnished with Class I Division II sealed and gasketed fixtures.


Industrial

Auto

Wood

OPEN FRONT BENCH BOOTH

Model Number

Interior Dimensions Exterior Dimensions Width Height Length Width Height Length

IBB-04-07-02 4'-0" IBB-05-07-03 5'-0" IBB-06-07-03 6'-0" IBB-08-07-03 8'-0" IBB-10-07-03 10'-0" IBB-12-07-03 12'-0"

4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0"

Ref. Key

B

A

2'-0" 4'-4" 3'-0" 5'-4" 3'-0" 6'-4" 3'-0" 8'-4" 3'-0" 10'-4' 3'-0" 12'-4" C

7'-2" 7'-2" 7'-2" 7'-2" 7'-2" 7'-2"

4'-2" 5'-2" 5'-2" 5'-2" 5'-2" 5'-8"

Qty. Qty. Lights Filters 0* 1 1 1 2 2

4 4 6 8 10 12

Fan Diameter 18" 18" 18" 18" 18" 24"

Fan HP

.75HP .75HP .75HP 1 HP 1.5 HP 1.5 HP

SCFM @ Shipping 1/2" SP 2,000 2,500 3,000 4,000 5,000 6,000

675 940 1,240 1,630 1,870 2,450

D

* Optional 36", two-tube light fixture available. COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Auto

Wood

ENCLOSED INDUSTRIAL BOOTH • EZ TO QUICK SHIP • EZ TO INSTALL • EZ TO OPERATE • EZ TO MAINTAIN

CROSSDRAFT

OR

MODIFIED DOWNDRAFT

•Control panel and other electric components can be purchased separately •ETL Listed when optional control panel is added

•Industry-leading light levels •Spray booth specific, dual voltage T-8 32-watt light fixtures •Air solenoid valve

•Windowed personnel access •Constructed from 18 gauge, doors are pre-hung in a heavy prime-quality steel gauge galvanized steel frame •All panels and support members for easy installation. are precision punched for easy •Product doors are field hung nut and bolt assembly on slotted hinges to facilitate •5/16” bolt with self locking nuts installation on uneven floors

OVERVIEW

Air flows in through the filtered double entry doors in the front of the booth, passes through the booth’s working area, and into the filtered exhaust chamber located in the rear of the booth. This filtered exhaust air is drawn through the exhaust plenum and discharged upward into the atmosphere through the exhaust stack. Our Industrial Enclosure booths make efficient use of your valuable floor space and are available in four heights to accommodate your needs.

LIGHTING FEATURES

Bright, full-booth illumination is provided by four 48˝, four-tube, 32-watt fluorescent light fixtures placed in the ceiling panels and side walls. Each is sealed behind clear tempered safety glass. All fixtures are UL listed and approved for their intended use and placement.


Industrial

Auto

Wood

ENCLOSED INDUSTRIAL BOOTH Model Number EIB-10-07-05-00 EIB-12-07-07-00 EIB-14-07-07-00 EIB-16-07-07-00 EIB-18-07-07-00 EIB-20-07-07-00

Interior Dimensions Width Height Length 10’-0" 7’-0" 5’-0" 12’-0" 7’-0" 7’-0" 14’-0" 7’-0" 7’-0" 16’-0" 7’-0" 7’-0" 18’-0" 7’-0" 7’-0" 20’-0" 7’-0" 7’-0"

Exterior Dimensions Width Height Length 10’-4” 7’-2” 7’-10” 12’-4” 7’-2” 9’-10” 15’-0” 7’-6” 10’-8” 17’-0” 7’-6” 10’-8” 19’-0” 7’-6” 10’-8” 21’-0” 7’-6” 10’-8”

Nominal Door Opening Qty. Width Height Qty Type Lights 9'-4" 6'-10.5" 1 Filtered 2 11'-4" 6'-10.5" 1 Filtered 2 2 13'-4" 6'-10.5" 1 Filtered 13'-4" 6'-10.5" 1 Filtered 2 3 13'-4" 6'-10.5" 1 Filtered 13'-4" 6'-10.5" 1 Filtered 4

EIB-10-08-05-00 EIB-12-08-07-00 EIB-14-08-07-00 EIB-16-08-07-00 EIB-18-08-07-00 EIB-20-08-07-00

10’-0" 8’-0" 12'-0" 8’-0" 14’-0" 8’-0" 16’-0" 8’-0" 18’-0" 8’-0" 20’-0" 8’-0"

5’-0" 7’-0" 7’-0" 7’-0" 7’-0" 7’-0"

10’-4” 12’-4” 15’-0” 17’-0” 19’-0” 21’-0”

8’-2” 8’-2” 8’-6” 8’-6” 8’-6” 8’-6”

7’-10” 10’-4” 10’-8” 10’-8” 10’-8” 11’-8”

9'-4" 11'-4" 13'-4" 13'-4" 13'-4" 13'-4"

7'-10.5" 7'-10.5" 7'-10.5" 7'-10.5" 7'-10.5" 7'-10.5"

1 1 1 1 1 1

Filtered Filtered Filtered Filtered Filtered Filtered

EIB-10-10-05-00 EIB-12-10-07-00 EIB-14-10-07-00 EIB-16-10-07-00 EIB-18-10-07-00 EIB-20-10-07-00

10’-0" 10’-0" 12’-0" 10’-0" 14’-0" 10’-0" 16’-0" 10’-0" 18’-0" 10’-0" 20’-0" 10’-0"

5’-0" 7’-0" 7’-0" 7’-0" 7’-0" 7’-0"

10’-4” 12’-4” 15’-0” 17’-0” 19’-0” 21’-0”

10’-2” 10’-2” 10’-6” 10’-6” 10’-6” 10’-6”

8’-4” 10’-4” 10’-8” 11’-8” 11’-8” 11’-8”

9'-4" 11'-4" 13'-4" 13'-4" 13'-4" 13'-4"

9'-10.5" 9'-10.5" 9'-10.5" 9'-10.5" 9'-10.5" 9'-10.5"

1 1 1 1 1 1

EIB-10-12-05-00 EIB-12-12-07-00 EIB-14-12-07-00 EIB-16-12-07-00 EIB-18-12-07-00 EIB-20-12-07-00

10’-0" 12’-0" 12’-0" 12’-0" 14’-0" 12’-0" 16’-0" 12’-0" 18’-0" 12’-0" 20’-0" 12’-0"

5’-0" 7’-0" 7’-0" 7’-0" 7’-0" 7’-0"

10’-4” 12’-4” 15’-0” 17’-0” 19’-0” 21’-0”

12’-2” 12’-2” 12’-6” 12’-6” 12’-6” 12’-6”

8’-4” 10’-4” 11’-8” 11’-8” 11’-8” 11’-8”

9'-4" 11'-10.5" 1 11'-4" 11'-10.5" 1 13'-4" 11'-10.5" 1 13'-4" 11'-10.5" 1 13'-4" 11'-10.5" 1 13'-4" 11'-10.5" 1

Reference Key

A

B

C

D

Filters Exhaust 20 24 32 36 40 44

Fan Diameter 24” 24” 30” 30” 30” 30”

Fan HP 2HP 3HP 3HP 3HP 3HP 5HP

SCFM @ 1/2” SP 7,000 8,400 9,800 11,200 12,600 14,000

2 2 2 2 3 4

20 24 32 36 40 44

24” 30” 30” 30” 30” 36”

3HP 3HP 3HP 5HP 5HP 5HP

8,000 9,600 11,200 12,800 14,400 16,000

Filtered Filtered Filtered Filtered Filtered Filtered

2 2 2 2 3 4

25 30 40 45 50 55

30” 30” 30” 36” 36” 42”

3HP 3HP 5HP 5HP 5HP 5HP

10,000 12,000 14,000 16,000 18,000 20,000

Filtered Filtered Filtered Filtered Filtered Filtered

2 2 2 2 3 4

30 36 48 54 60 66

30” 30” 36” 42” 42” 42”

3HP 12,000 5HP 14,400 5HP 16,800 5HP 19,200 5HP 21,600 7.5HP 24,000

E

Alternative Configuration: Pressurized Modified Downdraft (MD)

Col-Met Spray Booths - Rockwall, TX // e-mail: sales@colmetsb.com - Toll-free: 888.452.6684 // www.colmetsb.com COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Auto

Wood

EZ EXHAUST CHAMBERS • HEAVY DUTY CONSTRUCTION • MODULAR DESIGN ALLOWS FOR CONVERSION TO PAINT BOOTH • EASY TO INSTALL The EZ Exhaust Chamber is designed for exhausting dust, harmful vapors and paint fumes. The dry arrestor filters trap the airborne overspray particles before the filtered air is discharged through the exhaust system and into the atmosphere. The chambers are available in a wide range of designs to meet practically any production requirement. Air replacement units and intake chambers can be added as well as reduced airflows for automatic spray operations.

EXHAUST SYSTEM FEATURES

A tube axial exhaust fan, designed specifically for use in paint spray exhaust chambers, powers the airflow through the booth and exhaust stack. All exhaust fans are of nonsparking construction. The motor drive and bearings are sealed from the air stream of the exhaust. Motors are provided with each unit. Optional explosion-proof motor upgrade is required for flammable painting environments.

CONSTRUCTION FEATURES & QUALITY STANDARDS Chambers are constructed from 18-gauge, prime quality, galvanized steel. Structural steel is used to add strength and rigidity to chambers as necessary. Control panel is optional, fire control systems are to be supplied by others.

EZ EXHAUST BENCH This exhaust bench provides a very practical method for removing hazardous and contaminated air generated by refinish, repair and other shop-related operations. • Compact design saves valuable floor space. • Heavy-duty construction bench is fabricated with 18-gauge galvanized steel panels. • Promotes shop safety by exhausting harmful vapors and dust thereby reducing health hazards for shop personnel. • Optional explosion-proof motor upgrade is required for flammable painting environments.


Industrial

Auto

Wood

EZ EXHAUST CHAMBERS EZ CHAMBER

Model Number

Exterior Dimensions Qty. Width Height Length Filters

18" 24" 24" 30" 30" 30" 30" 36" 36"

Fan HP

.75HP 1HP 2HP 2HP 3HP 3HP 5HP 5HP 5HP

SCFM @ 1/2" SP

4'-4" 6'-4" 8'-4" 10'-4" 12'-4" 14'-4" 16'-4" 18'-4" 20'-4"

7'-2" 7'-2" 7'-2" 7'-2" 7'-2" 7'-2" 7'-2" 7'-2" 7'-2"

2'-2" 2'-8" 2'-8" 3'-2" 3'-2" 3'-6" 3'-6" 4'-6" 4'-6"

8 12 16 20 24 32 36 40 44

IBC-04-08 IBC-06-08 IBC-08-08 IBC-10-08 IBC-12-08 IBC-14-08 IBC-16-08 IBC-18-08 IBC-20-08

4'-4" 6'-4" 8'-4" 10'-4" 12'-4" 14'-4" 16'-4" 18'-4" 20'-4"

8'-2" 8'-2" 8'-2" 8'-2" 8'-2" 8'-2" 8'-2" 8'-2" 8'-2"

2'-2" 2'-8" 2'-8" 3'-2" 3'-2" 3'-6" 4'-6" 4'-6" 4'-6"

8 12 16 20 24 32 36 40 44

18" 24" 24" 30" 30" 30" 36" 36" 42"

1HP 1.5HP 3HP 3HP 3HP 5HP 5HP 5HP 5HP

4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000

IBC-04-10 IBC-06-10 IBC-08-10 IBC-10-10 IBC-12-10 IBC-14-10 IBC-16-10 IBC-18-10 IBC-20-10

4'-4" 6'-4" 8'-4" 10'-4" 12'-4" 14'-4" 16'-4" 18'-4" 20'-4"

10'-2" 10'-2" 10'-2" 10'-2" 10'-2" 10'-2" 10'-2" 10'-2" 10'-2"

2'-2" 2'-8" 3'-2" 3'-2" 3'-2" 4'-6" 4'-6" 4'-6" 4'-6"

10 15 20 25 30 40 45 50 55

18" 24" 30" 30" 30" 36" 42" 42" 42"

1.5HP 2HP 3HP 3HP 5HP 5HP 5HP 5HP 7.5HP

5,000 7,500 10,000 12,500 15,000 17,500 20,000 22,500 25,000

IBC-04-12 IBC-06-12 IBC-08-12 IBC-10-12 IBC-12-12 IBC-14-12 IBC-16-12 IBC-18-12 IBC-20-12

4'-4" 6'-4" 8'-4" 10'-4" 12'-4" 14'-4" 16'-4" 18'-4" 20'-4"

12'-2" 12'-2" 12'-2" 12'-2" 12'-2" 12'-2" 12'-2" 12'-2" 12'-2"

2'-8" 2'-8" 3'-2" 3'-2" 4'-2" 4'-6" 4'-6" 4'-6" 4'-6"

12 18 24 30 36 48 54 60 66

24" 24" 30" 30" 36" 42" 42" 42" 42"

1.5HP 3HP 3HP 5HP 5HP 5HP 7.5HP 7.5HP 10HP

6,000 9,000 12,000 15,000 18,000 21,000 24,000 27,000 30,000

Model Number

Exterior Dimensions CFM @ Width Height Length 1/2" SP

Fan Spec Dia. HP

EB-12 EB-15

12'-0" 15'-0"

3'-2" 3'-2"

2'-4" 2'-4"

18" 18"

A

B

C

IBC-04-07 IBC-06-07 IBC-08-07 IBC-10-07 IBC-12-07 IBC-14-07 IBC-16-07 IBC-18-07 IBC-20-07

EZ BENCH

Reference Key

PLAN VIEW

5,000 5,000

Fan Diameter

END VIEW

1.5 1.5

3,500 5,250 7,000 8,750 10,500 12,250 14,000 15,750 17,500

Filters Exhaust

Manometer

7 8

YES YES

SIDE ELEVATION

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Auto

Wood

EZ CLASSIC CROSSDRAFT • EZ TO INSTALL • EZ TO OPERATE • EZ TO MAINTAIN • EZ TO QUICK SHIP

•Control panel and other electric components can be purchased separately

•Industry-leading light levels •Spray booth specific, dual voltage T-8 32-watt light fixtures

•ETL listed when optional when control panel is added

•Quality brand-name tubeaxial fans and motors •Air solenoid valve

•Windowed personnel access doors are pre-hung in a heavy gauge galvanized steel frame for easy installation. •Product doors are field hung on slotted hinges to facilitate installation on uneven floors

•Constructed from 18 gauge, prime-quality steel •All panels and support members are precision punched for easy nut and bolt assembly •5/16” bolt with self locking nuts

OVERVIEW

The Col-Met EZ Crossdraft Booth intakes fresh air through filters in the product doors. The clean, filtered air is drawn through the booth and exhausted through a filter system at the opposite end. This type of spray booth makes efficient use of shop space, and is available in solid back, drive through and reverse flow designs. Reverse flow booths intake air through filters in the back wall. The solid-faced product access doors are at the exhaust end of the booth. This provides cleaner intake filtering and better control of shop dust that might be tracked in at the product entrance. This booth also available in either drive-through or solid back configurations.

LIGHTING FEATURES

Bright, full booth illumination is provided by ten 48" four-tube, 32-watt fluorescent light fixtures in the angled ceiling panels and side walls. Each is sealed behind clear, tempered safety glass. All fixtures are UL listed and approved for their intended use and placement.


Industrial

Auto

Wood

EZ CLASSIC CROSSDRAFT

Interior Dimensions Exterior Dimensions Access Model Width Height Length Width Height Length Doors Number 1 ECC-14-09-26-N-SB 14’-0” 9’-0” 26’-0” 14’-6.5” 10’-0" 26’-4” 1 ECC-14-09-28-N-SB 14’-0” 9’-0” 28’-0” 14’-6.5” 10’-0" 28’-4” 1 ECC-14-09-30-N-SB 14’-0” 9’-0” 30’-0” 14’-6.5” 10’-0" 30’-4”

Nominal Door Opening Lights Width Height Qty Type Open S&G 9’-4” 8’-10.5” 1 Filtered 9 1 9’-4” 8’-10.5” 1 Filtered 9 1 9’-4” 8’-10.5” 1 Filtered 9 1

Reference Key

E

A

B

C

D

Alternative Configurations: Reverse Flow (RF) Drive Through (DT) Alternative Options: Pressurized (P) Standard Length Sizing is Illustrated above

Air Flow Fan Spec. SCFM Dia. HP 12,600 30” 3HP 12,600 30” 3HP 12,600 30” 3HP

Filters Int. Exh. 20 16 20 16 20 16

F

Actual Working Depth is 18 inches less than interior length.

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Auto

Wood

EZ MODIFIED DOWNDRAFT • EZ TO INSTALL • EZ TO OPERATE • EZ TO MAINTAIN • EZ TO PRESSURIZE • EZ TO QUICK SHIP BOOTH SHOWN WITH OPTIONAL POWDER COATING OPTIONAL PREFILTERED PLENUM

•Control panel and other electric components can be purchased separately

•Industry-leading light levels

•ETL listed when optional control panel is added

•Quality brand-name tubeaxial fans and motors

•Spray booth specific, dual voltage T-8 32-watt light fixtures

•Air solenoid valve

•Windowed personnel access doors are pre-hung in a heavy gauge galvanized steel frame for easy installation. •Product doors are field hung on slotted hinges to facilitate installation on uneven floors

•Constructed from 18 gauge, prime-quality steel •All panels and support members are precision punched for easy nut and bolt assembly •5/16” bolt with self locking nuts

OVERVIEW

The Col-Met EZ Modified Downdraft Booth intakes fresh air from the cleaner upper levels of the shop through a filter bank located in the booth ceiling near the product doors. The filtered air is drawn down through the booth to an exhaust filter system at the other end. Optional prefiltered plenum for additional intake air filtration is available. This booth also available in either drivethrough or solid back configurations. The basic modified downdraft design allows for easy pressurization with the addition of an intake plenum with fan or a heated air make up unit.

LIGHTING FEATURES

Bright, full booth illumination is provided by ten four-tube, 48˝, 32-watt, fluorescent light fixtures in the angled ceiling panels and side walls. Each is sealed behind clear tempered safety glass. All fixtures are UL listed and approved for their intended use and placement.


Industrial

Auto

Wood

EZ MODIFIED DOWNDRAFT

Interior Dimensions Exterior Dimensions Access Model Width Height Length Width Height Length Doors Number 1 EMD-14-09-26-N-SB 14’-0” 9’-0” 26’-0” 14’-6.5” 10’-0" 26’-4” 14’-0” 9’-0” 28’-0” 14’-6.5” 10’-0" 28’-4” 1 EMD-14-09-28-N-SB 1 EMD-14-09-30-N-SB 14’-0” 9’-0” 30’-0” 14’-6.5” 10’-0" 30’-4” Reference Key

A

B

C

D

Alternative Configurations: Reverse Flow (RF) Drive Through (DT) Alternative Options: Pressurized (P) Pre-Filtered (PF) Standard Length Sizing is Illustrated above

Nominal Door Opening Lights Width Height Qty Type Open S&G 9’-4” 8’-10.5” 1 Solid 9 1 9’-4” 8’-10.5” 1 Solid 9 1 9’-4” 8’-10.5” 1 Solid 9 1 E

Air Flow Fan Spec. SCFM Dia. HP 12,600 30” 3HP 12,600 30” 3HP 12,600 30” 3HP

Filters Int. Exh. 15 16 15 16 15 16

F

Actual Working Depth is 18 inches less than interior length.

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Auto

Wood

EZ SIDE DOWNDRAFT • EZ TO INSTALL • EZ TO OPERATE • EZ TO MAINTAIN • EZ TO PRESSURIZE BOOTH SHOWN WITH OPTIONAL POWDER COATING

•Control panel and other electric components can be purchased separately •ETL listed when optional when control panel is added

•Industry-leading light levels •Spray booth specific, dual voltage T-8 32-watt light fixtures •Quality brand-name tubeaxial fans and motors •Air solenoid valve

•Windowed personnel access doors are pre-hung in a heavy gauge galvanized steel frame for easy installation. •Product doors are field hung on slotted hinges to facilitate installation on uneven floors

•Constructed from 18 gauge, prime-quality steel •All panels and support members are precision punched for easy nut and bolt assembly •5/16” bolt with self locking nuts

OVERVIEW

The Col-Met EZ Side Downdraft Booth intakes fresh air from the cleaner upper levels of the shop through a filtered booth ceiling. The filtered air is drawn down and away from the product through exhaust filters at the floor level, along both sides. This provides efficient overspray control that reduces prep time and also provides a much healthier workplace environment without an expensive downdraft exhaust pit. This booth can also be purchased with a pre-filtered plenum or with a pressurized intake plenum, the booth can also be equipped with an air replacement unit and cure cycle to meet your requirements. This booth also available in either drive-through or solid back configurations.

LIGHTING FEATURES

Bright, full booth illumination is provided by ten four-tube, 48", 32-watt, fluorescent light fixtures in the angled ceiling panels and side walls. Each is sealed behind clear, tempered safety glass. All fixtures are UL listed and approved for their intended use and placement.


Industrial

Auto

Wood

EZ SIDE DOWNDRAFT

Model Interior Dimensions Exterior Dimension Access Nominal Door Opening Number Width Height Length Width Height Length Doors Width Height Qty Type ESD-14-09-26-N-SB 14’-0” 9’-0” 26’-0” 16’-4” 10’ -0" 26’-4” 1 9’-4” 8’-10.5” 1 Solid Reference Key

A

B

C

D

E

Lights Air Flow Fan Spec. Open S&G SCFM Dia. HP 9 1 12,740 (2) 24” 2HP

F

Alternative Configurations: Drive Through (DT) Alternative Options: Pressurized (P) Pre-Filtered (PF) Standard Length Sizing is Illustrated above

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS

Filters Int. Exh. 32 20


Industrial

Auto

Wood

EZ PIT DOWNDRAFT • EZ TO INSTALL • EZ TO OPERATE • EZ TO MAINTAIN • EZ TO PRESSURIZE BOOTH SHOWN WITH OPTIONAL ABOVE GROUND BASEMENT

•Control panel and other electric components can be purchased separately

•Industry-leading light levels •Spray booth specific, dual voltage T-8 32-watt light fixtures

•ETL listed when optional when control panel is added

•Quality brand-name tubeaxial fans and motors •Air solenoid valve

Windowed personnel access doors are pre-hung in a heavy gauge galvanized steel frame for easy installation. •Product doors are field hung to facilitate installation on uneven floors

•Constructed from 18 gauge, prime-quality steel •All panels and support members are precision punched for easy nut and bolt assembly •5/16” bolt with self locking nuts

OVERVIEW

The EZ Pit Downdraft Booth takes in fresh air from the cleaner upper levels of the shop, through a filtered booth ceiling. The filtered air is drawn down and away from the product through exhaust filters in the pit located in the floor. This provides efficient overspray control that reduces prep time and also provides a much healthier workplace environment. An optional above ground basement exhaust plenum is available for installation without concrete work. This booth can be purchased with a pre-filtered plenum or with a pressurized intake plenum. It can also be equipped with an air replacement unit and cure cycle to meet your requirements. The EZ Pit Downdraft Booth is available in either drive-through or solid back configurations.

LIGHTING FEATURES

Bright, full booth illumination is provided by ten four-tube, 48˝, 32-watt fluorescent light fixtures in the angled ceiling panels and side walls. Each is sealed behind clear tempered safety glass. All fixtures are UL listed and approved for their intended use and placement.


Industrial

Auto

Wood

EZ PIT DOWNDRAFT

Interior Dimensions Exterior Dimensions Model Width Height Length Width Height Length Number EPD-14-09-26-N-SB 14'-0" 9'-0" 26'-0" 14'-10.5" 10'-0" 26'-4" Reference Key

A

B

C

D

Access Nominal Door Opening Illumination Air Flow Doors Width Height Qty Type S&G Open Total SCFM 1 9'-4" 8'-10.5" 1 Solid 1 9 10 12,740 E

F

Alternative Configurations: Drive Through (DT) Alternative Options: Pressurized (P) Pre-Filtered (PF) Standard Length Sizing is Illustrated above

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS

Fan Spec. Filters Dia. HP Int. Exh. 30" 3 HP 32 24


EZ PAINT MIXING ROOM • EZ TO INSTALL • EZ TO OPERATE • EZ TO MAINTAIN • EZ TO QUICK SHIP SHOWN WITH OPTIONAL POWDER COATING

•Control panel and other electric components can be purchased separately

•Industry-leading light levels •Spray booth specific, dual voltage T-8 32-watt light fixtures

•ETL listed when optional control panel is added

•Quality brand-name tubeaxial fans and motors

•Personnel access doors are pre-hung in a heavy gauge galvanized steel frame for easy installation.

•Constructed from 18 gauge, prime-quality steel •All panels and support members are precision punched for easy nut and bolt assembly •5/16” bolt with self locking nuts

OVERVIEW

Air flows in through the filtered air intake panel (located in the ceiling toward one end of the room), downward through the work area, and into the exhaust chamber located in the lower opposite end of the room. Filtered exhaust air is drawn through the exhaust plenum and is discharged upward into the atmosphere through the exhaust stack.

LIGHTING FEATURES

Bright, full room illumination is provided by 48" four-tube, 32-watt clear, fluorescent light fixtures in the ceiling panels. Each is sealed behind clear, tempered safety glass. All fixtures are UL listed and approved for their intended use and placement.


EZ PAINT MIXING ROOM

Model Number

PMR-08-08-08 PMR-08-08-10 PMR-08-08-12 PMR-08-08-15 PMR-10-08-15 Ref. Key

Interior Dimensions

Exterior Dimensions

Access

Lights

Width Height Length Width Height Length Doors Open S&G 8'-0" 8'-0" 8'-0" 8'-4" 8'-2" 10'-6" 1 with Window 1 0 8'-0" 8'-0" 10'-0" 8'-4" 8'-2" 12'-6" 1 with Window 1 1 8'-0" 8'-0" 12'-0" 8'-4" 8'-2" 14'-6" 1 with Window 1 1 8'-0" 8'-0" 15'-0" 8'-4" 8'-2" 17'-6" 1 with Window 2 1 10'-0" 8'-0" 15'-0" 10'-4" 8'-2" 17'-6" 1 with Window 2 1 A B C D

Air Flow

SCFM 1450 1450 1450 1450 1450

Fan Spec.

Dia. 12" 12" 12" 12" 12"

HP ¾ HP ¾ HP ¾ HP ¾ HP ¾ HP

Filters

Int. Exh. 4 2 4 2 4 2 4 2 4 2

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Auto

Wood

EZ LIMITED FINISHING PREP STATION • EZ TO INSTALL • EZ TO OPERATE

• EZ TO MAINTAIN • EZ TO ADD HEAT

CONSTRUCTION FEATURES AND QUALITY STANDARDS

BOOTH SHOWN WITH OPTIONAL CURTAINS

The Hanging Intake Plenum and Exhaust Plenum Wall will be fabricated with 18-gauge galvanized steel panels; flanged for strength and pre-punched for easy nut and bolt assembly. The intake plenum may be suspended with a maximum of 10’ tall clearance or as low as 7’ tall clearance. The actual installed height is required to order the Goff’s™ Curtain walls. Intake air is supplied by one (1) 18” diameter tubeaxial fan with a 1-1/2 HP, three-phase motor. Exhaust is provided by one (1) 18” diameter tubeaxial fan with a 1-1/2 HP, three-phase motor. Col-Met Spray Booths’ EZ Limited Finishing Prep Station complies with NFPA 33 regulations pertaining to limited finishing workstations. Optional ETL listing with purchase of control panel and curtains is availabe.

OVERVIEW

The Col-Met EZ Limited Finishing Prep Station draws fresh air from the cleaner upper levels of the shop through a pressurization fan. This air is forced down into the prep station through a filter bank located in the ceiling near the entry. The air is drawn through the prep station work area into a filtered exhaust plenum at the opposite end and exhausted out to the atmosphere through the exhaust fan and stack. This design allows for easy addition of a heated air makeup unit. Panels, assembly hardware, filters, and sealants needed for mechanical installation are included. The threaded rod for suspending the intake plenum is not supplied by Col-Met. Goff’s™ Curtain walls, intake and exhaust stack, control panel, and other electrical components may be purchased separately.

LIGHTING FEATURES

Bright, full booth illumination is provided by eight (8) four-tube, 48˝ long, 32-watt, fluorescent light fixtures in the ceiling panels. Each is sealed behind clear tempered safety glass. All fixtures are UL listed and approved for their intended use and placement.


Industrial

Auto

Wood

EZ LIMITED FINISHING PREP STATION

Model Number EPS-14-10-24-P-SB Reference Key

Interior Dimensions Exterior Dimensions Nominal Clear Entry Lights Air Flow Width Height Length Width Height Length Width Height Open SCFM 14’-0” 10’-0” 24’-0” 14’-4” 12’-2” 26’-6” 14’-0” 10’-0” 8 5,000 A

B

Fan Spec. Dia. HP (2)18” 1.5

Filters Int. Ext. 12 12

C

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Powder

500° POWDER CURE BATCH OVEN Technical Data • Chart dimensions are width, height and depth • Interior dimensions are clear between ducts, walls, floor and top • Allow a minimum of 6” between parts and ducts for airflow • Stack is not included with the oven but can be purchased as an option • Eclipse Version 2 air heat burners • All specifications are subject to change with out notice • Larger ovens will be shipped unassembled with factory tested and assembled burner and recirculation unit • Heater Box is factory tested

Construction • Angle iron frames in all models • 4” insulated panel construction • Aluminized steel construction • 16 ga. aluminized steel duct • Explosion relief doors with FM approved latches

COL-MET STANDARD CONTROLS

COL-MET SMART TOUCH CONTROLS

•3 Phase Main Circuit Breaker •UL/CUL Listed Control Panel in NEMA12 Enclosure. •Motor Contactors for all motors. •Motor Protectors for all motors. •Toggle switches for on/off control of fans, burner, and batch timer. •Analog 1 second to 300 hour batch timer. •Digital temperature controller. •Digital high temperature limit with rollback protection. •FM Approved Gas Train with high pressure, low pressure, and proof of closure safety switches. Includes ventless regulator and dual blocking valve. 2 – 5 P.S.I. recommended gas pressure. •Air proving switches for all critical fans. •Terminal strip to connect control panel to burner box. •UV scanner flame monitoring for reliable start-up.

•3 Phase Main Circuit Breaker •UL/CUL Listed Control Panel in NEMA12 Enclosure. •Motor Contactors for all motors. •Motor Protectors for all motors. •6” Touchscreen with 4 batch modes and troubleshooting capabilities. •1 second to 16 hour digital batch timer with countdown indication. •Digital self-tuning temperature controller. •Digital high temperature limit with rollback protection. •FM Approved Gas Train with high pressure, low pressure, and proof of closure safety switches. Includes ventless regulator and dual blocking valve. 2 – 5 P.S.I. recommended gas pressure. •Air proving switches for all critical fans. •Control panel prewired to burner box, only field wiring needed is exhaust fan and communication between main panel and touchscreen. •Digital password protected purge timer for safer operation. •UV scanner flame monitoring for reliable start-up. •230V/480V 3 Phase 60Hz •Available VFD control on exhaust fan for faster purge and

•230V/480V 3 Phase 60Hz

Standard Control Panels and Smart Touch Control Panels are both UL/CUL Listed in NEMA12 Enclosure.

cool-down times.


Industrial

Powder

500° POWDER CURE BATCH OVEN Model Number

W

Inside (Ft.-0”) H D

Single Entry Outside W H D

Double Entry Outside W H D

Recirculating Fan Exhaust Fan Burner SCFM HP SCFM HP BTU HP

BO-05-06-05-SE 5'-0" 6'-0" 5'-0" 7’-4” 7’-4” 10’-2” 7’-4” 11’-0” 5’-10” 1,500 BO-05-06-06-SE 5'-0" 6'-0" 6'-0" 7’-4” 7’-4” 11’-2” 7’-4” 11’-0” 6’-10” 1,800 BO-05-06-07-SE 5'-0" 6'-0" 7'-0" 7’-4” 7’-4” 12’-2” 7’-4” 11’-0” 7’-10” 2,100 BO-05-06-08-SE 5'-0" 6'-0" 8'-0" 7’-4” 7’-4” 13’-2” 7’-4” 11’-0” 8’-10” 2,400 BO-05-06-10-SE 5'-0" 6'-0" 10'-0" 7’-4” 7’-4” 14’-2” 7’-4” 11’-0” 10’-10” 3,000 BO-05-06-12-SE 5'-0" 6'-0" 12'-0" 7’-4” 7’-4” 16’-2” 7’-4” 11’-0” 12’-10” 3,600 BO-06-06-06-SE 6'-0" 6'-0" 6'-0" 8’-4” 7’-4” 11’-2” 8’-4” 11’-0” 6’-10” 2,160 BO-06-06-08-SE 6'-0" 6'-0" 8'-0" 8’-4” 7’-4” 13’-2” 8’-4” 11’-0” 8’-10” 2,880 BO-06-06-10-SE 6'-0" 6'-0" 10'-0" 8’-4” 7’-4” 15’-2” 8’-4” 11’-0” 10’-10” 3,600 BO-06-06-12-SE 6'-0" 6'-0" 12'-0" 8’-4” 7’-4” 17’-2” 8’-4” 11’-0” 12’-10” 4,320 BO-06-06-14-SE 6'-0" 6'-0" 14'-0" 8’-4” 7’-4” 19’-2” 8’-4” 11’-6” 14’-10” 5,040 BO-06-06-16-SE 6'-0" 6'-0" 16'-0" 8’-4” 7’-4” 21’-2” 8’-4” 11’-6” 16’-10” 5,760 BO-06-07-06-SE 6'-0" 7'-0" 6'-0" 8’-4” 8’-4” 11’-2” 8’-4” 12’-0” 6’-10” 2,520 BO-06-07-08-SE 6'-0" 7'-0" 8'-0" 8’-4” 8’-4” 13’-2” 8’-4” 12’-0” 8’-10” 3,360 BO-06-07-10-SE 6'-0" 7'-0" 10'-0" 8’-4” 8’-4” 14’-2” 8’-4” 12’-6” 10’-10” 4,200 BO-06-07-12-SE 6'-0" 7'-0" 12'-0" 8’-4” 8’-4” 16’-2” 8’-4” 12’-6” 12’-10” 5,040 BO-06-07-14-SE 6'-0" 7'-0" 14'-0" 8’-4” 8’-4” 18’-2” 8’-4” 12’-6” 14’-10” 5,880 BO-06-07-16-SE 6'-0" 7'-0" 16'-0" 8’-4” 9’-4” 20’-4” 8’-4” 12’-6” 16’-10” 6,720 BO-06-08-06-SE 6'-0" 8'-0" 6'-0" 8’-4” 9’-4” 11’-2” 8’-4” 12’-6” 6’-10” 2,880 BO-06-08-08-SE 6'-0" 8'-0" 8'-0" 8’-4” 9’-4” 13’-2” 8’-4” 12’-6” 8’-10” 3,840 BO-06-08-10-SE 6'-0" 8'-0" 10'-0" 8’-4” 9’-4” 15’-2” 8’-4” 13’-6” 10’-10" 4,800 BO-06-08-12-SE 6'-0" 8'-0" 12'-0" 8’-4” 9’-4” 17’-2” 8’-4” 13’-6” 12’-10” 5,760 BO-06-08-14-SE 6'-0" 8'-0" 14'-0" 8’-4” 9’-4” 19’-4” 8’-4” 13’-6” 14’-10” 6,720 BO-06-08-16-SE 6'-0" 8'-0" 16'-0" 8’-4” 9’-4” 21’-4” 8’-4” 13’-6” 16’-10” 7,680 BO-07-07-07-SE 7'-0" 7'-0" 7'-0" 9’-4” 8’-4” 12’-8” 8’-4” 12’-0” 7’-10” 3,430 BO-07-07-08-SE 7'-0" 7'-0" 8'-0" 9’-4” 8’-4” 13’-8” 8’-4” 12’-0” 8’-10” 3,920 BO-07-07-10-SE 7'-0" 7'-0" 10'-0" 9’-4” 8’-4” 16’-2” 8’-4” 12’-6” 10’-10” 4,900 BO-07-07-12-SE 7'-0" 7'-0" 12'-0" 9’-4” 8’-4” 18’-2” 8’-4” 12’-6” 12’-10” 5,880 BO-07-07-14-SE 7'-0" 7'-0" 14'-0" 9’-4” 8’-4” 20’-2” 8’-4” 12’-6” 14’-10” 6,860 BO-07-07-16-SE 7'-0" 7'-0" 16'-0" 9’-4” 8’-4” 22’-8” 8’-4” 12’-8” 16’-10” 7,840 BO-08-08-08-SE 8'-0" 8'-0" 8'-0" 10’-10” 9’-4” 14’-8” 10’-10” 13’-10” 8’-10” 5,120 BO-08-08-10-SE 8'-0" 8'-0" 10'-0" 10’-10” 9’-4” 16’-8” 10’-10” 13’-10” 10’-10” 6,400 BO-08-08-12-SE 8'-0" 8'-0" 12'-0" 10’-10” 9’-4” 18’-10” 10’-10” 14’-0” 12’-10” 7,680 BO-08-08-14-SE 8'-0" 8'-0" 14'-0" 10’-10” 9’-4” 20’-10” 10’-10” 14’-0” 14’-10” 8,960 BO-08-08-16-SE 8'-0" 8'-0" 16'-0" 10’-10” 9’-4” 21’-10” 10’-10” 14’-0” 16’-10” 10,240 BO-08-08-20-SE 8'-0" 8'-0" 20'-0" 10’-10” 9’-4” 27’-8” 10’-10” 14’-6” 20’-10” 12,800 BO-08-10-08-SE 8'-0" 10'-0" 8'-0" 10’-10” 11’-4” 14’-4” 10’-10” 15’-10” 8’-10” 6,400 BO-08-10-10-SE 8'-0" 10'-0" 10'-0" 10’-10” 11’-4” 16’-4” 10’-10” 15’-10” 10’-10” 8,000 BO-08-10-12-SE 8'-0" 10'-0" 12'-0" 10’-10” 11’-4” 18’-4” 10’-10” 15’-10” 12’-10” 9,600 BO-08-10-14-SE 8'-0" 10'-0" 14'-0" 10’-10” 11’-4” 16’-4” 10’-10” 16’-0” 14’-10” 11,200 BO-08-10-16-SE 8'-0" 10'-0" 16'-0" 10’-10” 11’-4” 18’-10” 10’-10” 17’-2” 16’-10” 12,800 BO-10-10-10-SE 10'-0" 10'-0" 10'-0" 12’-10” 11’-4” 17’-0” 10’-10” 17’-2” 10’-10” 10,000 BO-10-10-12-SE 10'-0" 10 -0" 12'-0" 12’-10” 11’-4” 19’-6” 10’-10” 17’-2” 12’-10” 12,000 BO-10-10-14-SE 10'-0" 10-0" 14'-0" 12’-10” 11’-4” 21’-6” 10’-10” 17’-2” 14’-10” 14,000

1.5 1.5 2 2 3 5 2 3 5 5 5 5 5 5 5 5 5 5 3 3 5 5 5 7.5 5 3 5 5 7.5 7.5 5 5 7.5 7.5 10 10 5 7.5 10 10 10 10 10 10

500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 750 500 500 500 750 1,000 1,350 500 750 1,000 1,000 1,000 1,000 1,000 1,350

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

500 0.33 500 0.33 500 0.33 500 0.33 500 0.33 500 0.33 500 0.33 500 0.33 500 0.33 500 0.33 500 0.33 1,000 0.33 500 0.33 500 0.33 500 0.33 500 0.33 1,000 0.33 1,000 0.33 500 0.33 500 0.33 500 0.33 500 0.33 1,000 0.33 1,000 0.33 500 0.33 500 0.33 500 0.33 1,000 0.33 1,000 0.33 1,000 0.33 500 0.33 1,000 0.33 1,000 0.33 1,000 0.33 1,000 0.33 1,500 0.33 1,000 0.33 1,000 0.33 1,000 0.33 1,500 0.33 1,500 0.33 1,000 0.33 1,500 0.33 1,500 0.33

Alternative Configurations: Double Entry (DE)

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS

AREA

150 180 210 240 300 360 216 288 360 432 504 576 252 336 420 504 588 672 288 384 480 576 672 768 343 392 490 588 686 784 512 640 768 896 1,024 1,280 640 800 960 1,120 1,280 1,000 1,200 1,400

Gas Train

1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1” NPT 1.5” NPT 1” NPT 1” NPT 1” NPT 1.5” NPT 1.5” NPT 1” NPT 1.5” NPT 1.5” NPT


Industrial

Powder

BATCH POWDER BOOTH • HEAVY DUTY CONSTRUCTION • LOW MAINTENANCE • EASY TO INSTALL • SPRAY-TO-WASTE DESIGN • RECIRCULATES SHOP AIR -NO AIR MAKEUP NEEDED

POWDER EXHAUST FILTER PROVING ASSEMBLY

•Control panel and other electric components can be purchased separately

•Industry-leading light levels

•Air solenoid valve

•Spray booth specific, dual voltage T-8 32-watt light fixtures

•Constructed from 18 gauge, prime-quality steel •All panels and support members are precision punched for easy nut and bolt assembly •5/16” bolt with self locking nuts

OVERVIEW The Batch Powder Booth makes efficient use of shop space and is designed for batch powder coating with no provisions for powder reclamation. Air is drawn in through the open front of the spray booth, passes through the booth’s working area into the filtered exhaust plenum. The air is filtered in three stages and discharged back into the room. One set of filters will be provided with each booth. • 1st stage – blanket style filter • 2nd stage – bag style filter • 3rd (final) stage – Hepa type filter

Control panel and VFD included


Industrial

Powder

BATCH POWDER BOOTH

Model Number PB-04-07-05 PB-06-07-05 PB-08-07-05 PB-10-07-05 PB-12-07-07 PB-14-07-07 PB-16-07-07 PB-04-08-05 PB-06-08-05 PB-08-08-05 PB-10-08-07 PB-12-08-07 PB-14-08-07 PB-16-08-07 PB-04-10-05 PB-06-10-05 PB-08-10-05 PB-10-10-05 PB-12-10-07 PB-14-10-07 PB-16-10-07 Reference Key

Interior Dimensions Exterior Dimensions Width Height Length Width Height Length 4'-0" 7'-0" 5'-0" 4'-4" 12'-0" 8'-4" 6'-0" 7’-0" 5'-0" 6'-4" 12'-0" 8'-6" 8'-0" 7'-0" 5'-0" 8'-4" 12'-0" 8'-6" 10'-0" 7'-0" 5'-0" 10'-4" 12'-0" 9'-0" 12'-0" 7'-0" 7'-0" 12'-4" 13'-0" 11'-0" 14'-0" 7'-0" 7'-0" 15'-0" 13'-0" 11'-2" 16'-0" 7'-0" 7'-0" 17'-0" 12'-0" 10'-8" 4'-0" 8'-0" 5'-0" 4'-4" 13'-0" 8'-4" 6'-0" 8'-0" 5'-0" 6'-4" 13'-0" 8'-6" 8'-0" 8'-0" 5'-0" 8'-4" 13'-0" 8'-6" 10'-0" 8'-0" 5'-0" 10'-2" 14'-0" 9'-0" 12'-0" 8'-0" 7'-0" 12'-4" 14'-0" 11'-0" 14'-0" 8'-0" 7'-0" 15'-0" 13'-0" 10'-8" 16'-0" 8'-0" 7'-0" 17'-0" 13'-0" 10'-8" 4'-0" 10'-0" 5'-0" 4'-4" 15'-0" 8'-6" 6'-0" 10'-0" 5'-0" 6'-4" 15'-0" 8'-6" 8'-0" 10'-0" 5'-0" 8'-4" 16'-0" 9'-8" 10'-0" 10'-0" 5'-0" 10'-4" 15'-0" 8'-6" 12'-8" 10'-0" 7'-0" 12'-4" 15'-0" 10'-6" 14'-0" 10'-0" 7'-0" 15'-0" 15'-0" 11'-2" 16'-0" 10'-0" 7'-0" 17'-0" 16'-0" 11'-2" A

B

C

D

E

Total CFM 2,800 4,200 5,600 7,000 8,400 9,800 11,200 3,200 4,800 6,400 8,000 9,600 11,200 12,800 4,000 6,000 8,000 10,000 12,000 14,000 16,000

Fan Specs. Dia. HP 18" 1.5 24" 2 24" 3 30" 3 30" 5 30" 5 3 2 (5600CFM) 24" 1 18" 2 1 24" 2 1 24" 3 1 30" 5 1 30" 5 3 2 (5600CFM) 24" 3 2 (6400CFM) 24" 1 24" 2 1 24" 3 1 30" 5 3 2 (5000CFM) 24" 3 2 (6000CFM) 24" 3 2 (7000CFM) 30" 5 2 (8000CFM) 30" Qty. 1 1 1 1 1 1

F

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS

Lights S&G 1 1 1 2 2 2 2 1 1 1 2 2 2 2 1 1 1 2 2 2 2


Industrial

Powder

CARTRIDGE BATCH POWDER BOOTH WITH NON-ROLLAWAY CASTER BASE PANELS

Panels are fabricated from 18-gauge prime quality galvanized steel, flanged and precision punched on 6˝ centers for maximum rigidity. Panels are fastened together with 5/16 inch bolts with self locking nuts and are to be sealed with the provided caulk following assembly.

ILLUMINATION

Lighting is provided by Class I Division II, 48˝ long, fluorescent, 32-watt, T-8 type fixtures (four-tube), mounted behind safety glass; appropriately sealed from the interior of the spray booth. All fixtures are UL listed and approved for their intended use and placement.

POWDER COLLECTOR STYLE BOOTH

PURGE CONTROL

This feature assures the safe operation of the coatings enclosure, by maintaining the airflow at design levels. During operation overspray powder accumulates on the cartridge filters. As the cartridge filters load, airflow decreases and negative pressure rises within the air handler. A timer activates a system of air purging valves that clear the cartridge filters of accumulated powder to ensure maximum filter life.

CONTROL EQUIPMENT

• NEMA 12 Remote Electrical Panel • Primary Disconnect • Automatic Purge/Pulse Control • Main Air Line Disconnect • Magnehelic Pressure Gauge CARTRIDGE COLLECTOR

COLLECTOR MODULE • Factory-assembled, powder coated white mild steel construction • Spark-proof construction plug type fan • Pulse valves and solenoids • Primary filter modules: cartridge type • Final filter modules: HEPA type filters 24" X 24" X 12" • Removable powder drawer • Optional fluidized bed available • Filter proving switch and solenoid valve included • Control panel and VFD included • Fork truck tubes for transfer • Air Solenoid Valve

Control panel and VFD included


Industrial

Powder

CARTRIDGE BATCH POWDER BOOTH WITH NON-ROLLAWAY CASTER BASE

CARTRIDGE COLLECTORS Model Number RPC-4000 RPC-5000 RPC-6000 RPC-7000 RPC-8000

Interior Dimensions Width Height Length N/A N/A N/A N/A N/A

N/A N/A N/A N/A N/A

N/A N/A N/A N/A N/A

Width

Exterior Dimensions Height

Length

Total CFM

Modules Modules

Cartridge Filters

Final Filters

Fan Spec. Qty. HP

Lights S&G

Fan Spec. Qty. HP

Lights S&G

4’-8” (w/CP 5’-10”) 8’-8” (w/MFD 9’-4”) 4’-4” (w/ Motor 6’-1”) 4000 @3” SP 4’-8” (w/CP 5’-10”) 8’-8” (w/MFD 9’-4”) 4’-4” (w/ Motor 6’-1”) 5000 @3” SP 6’-0” (w/CP 7’-2”) 8’-8” (w/MFD 9’-4”) 5’-3” (w/ Motor 6’-2”) 6000 @3” SP 6’-0” (w/CP 7’-2”) 8’-8” (w/MFD 9’-4”) 5’-3” (w/ Motor 6’-2”) 7000 @3” SP 6’-0” (w/CP 7’-2”) 8’-8” (w/MFD 9’-4”) 5’-3” (w/ Motor 6’-2”) 8000 @3” SP

1 1 1 1 1

4 5 6 7 7

4 4 6 6 6

1 1 1 1 1

5 HP 7.5 HP 7.5 HP 10 HP 10 HP

N/A N/A N/A N/A N/A

POWDER BOOTHS Model Number

Interior Dimensions Width Height Length

Width

Exterior Dimensions Height

Length

Total CFM

Modules

Cartridge Filters

Final Filters

RPB -08-07-7.5 7’-0” RPB-08-08-7.5 8’-0” RPB-08-10-7.5 8’-0”

8’-0” 8’-0” 10’-0”

7’-6” 7’-6” 7’-6”

8’-4” 8’-4” 8’-4”

9’-4” 9’-4” 10’-2”

13’-8” 13’-8” 13’-8”

6000 @3” SP 6000 @3” SP 8000 @3” SP

1 (6,000 CFM) 1 (6,000 CFM) 1 (8,000 CFM)

6 6 7

6 6 6

1 1 1

7.5 HP 7.5 HP 10 HP

1 1 1

RPB-10-07-7.5 10’-0” RPB-10-08-7.5A 10’-0” RPB-10-08-7.5B 10’-0” RPB-10-10-7.5 10’-0”

7’-0” 8’-0” 8’-0” 10’-0”

7’-6” 7’-6” 7’-6” 7’-6”

10’-4” 10’-4” 10’-4” 10’-4”

9’-4” 9’-4” 9’-4” 10’-2”

13’-8” 13’-8” 13’-7” 13’-7”

7000 @3” SP 8000 @3” SP 8000 @3” SP 10000 @3” SP

1 (7,000 CFM) 1 (8,000 CFM) 2 (4,000 CFM) 2 (5,000 CFM)

7 7 7 9

6 6 8 8

1 1 2 2

10 HP 10 HP 5 HP 7.5 HP

2 2 2 2

RPB-12-07-7.5A 12’-0” RPB-12-07-7.5B 12’-0” RPB-12-08-7.5 12’-0” RPB-12-10-7.5 12’-0”

7’-0” 7’-0” 8’-0” 10’-0”

7’-6” 7’-6” 7’-6” 7’-6”

12’-4” 12’-4” 12’-4” 12’-4”

9’-4” 9’-4” 9’-4” 10’-2”

13’-8” 13’-7” 13’-7” 13’-7”

8000 @3” SP 8000 @3” SP 10000 @3” SP 12000 @3” SP

1 (8,000 CFM) 2 (4,000 CFM) 2 (5,000 CFM) 2 (6,000 CFM)

7 7 9 9

6 8 8 12

1 2 2 2

10 HP 5 HP 7.5 HP 7.5 HP

2 2 2 2

B

C

D

E

F

Reference Key

A

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Powder

EZ PASS THRU POWDER BOOTH Parts enter the booth through the conveyor openings, then pass the coating operator stations to receive the coating. The powder overspray is entrained within the air stream moving to the collector module, where the cartridge filters will remove the particulate. The containment air is drawn through the air handler’s primary and final filter system before being discharged back into the room. Coated parts exit the booth for conveyance to the cure oven.

CONTROL EQUIPMENT • NEMA 12 Remote Electrical Panel • Primary Disconnect • Automatic Purge/Pulse Control • Main Air Line Disconnect • Magnehelic Pressure Gauge

ILLUMINATION

Lighting is provided by four Class I Division II, 48" long, fluorescent, 32-watt, T-8 type fixtures (four-tube), mounted behind safety glass; appropriately sealed from the interior of the spray booth. All fixtures are UL listed and approved for their intended use and placement. NOTE: Lexan™ roof panels may be substituted for the light fixtures.

SHOWN WITH STAINLESS STEEL OPTION & LEXAN ROOF OPTION

PURGE CONTROL

This feature assures the safe operation of the coatings enclosure, by maintaining the airflow at design levels. During operation overspray powder accumulates on the cartridge filters. The term for this is “loading”; as the cartridge filters “load”, airflow decreases and suction pressure rises within the air handler. A timer activates a system of air purging valves that clear the cartridge filters of accumulated powder as needed.

SAFETY EQUIPMENT

• One (1) Air Interlock Solenoid Valve is provided with this booth. • Filter Proving Switch is provided with this booth. • Flame/Spark Detection (if required) will be provided by others.

POWDER BOOTH WITH COLLECTOR MODULE

CONSTRUCTION FEATURES AND QUALITY STANDARDS • Booths are constructed from 18 gauge, prime-quality galvanized steel • All panels and support members are precision punched for easy nut and bolt assembly • Quality brand-name plug fans and motors • 5/16 inch bolts with self locking nuts • Industry-leading light levels • Spray booth specific, dual voltage T-8 32-watt light fixtures • Air solenoid valve and filter proving switch included • Stainless steel option available • Control panel and VFD is included

Control panel and VFD included


Industrial

Powder

EZ PASS THRU POWDER BOOTH COLLECTOR MODULE

AVAILABLE OPTIONS

• • • •

• Additional Rollaway Filter Module with Fluidized Bed (includes 1 set of filters) • Cabin Upgrade to 18 gauge #304 Stainless Steel • Floor & Base Assembly Upgrade to Formed 10 gauge #304 Stainless Steel • Roll-off Base Assembly • Air Package - includes plumbing to fluidized bed & four regulator air manifolds • 110V Electrical Outlet in Control Panel

Factory Assembled Powder Coated White 10 Gauge Mild Steel Construction Spark-Proof Construction Plug Type Fan Pulse Valves and Solenoids Rollaway Filter Module with Fluidized Bed

The use of Rollaway Filter Modules allows for a quicker color change since the filter section does not have to be cleaned between color change outs. • Primary Filter Modules: Clark™ Filter #1566093 (or equal) 12.75" dia. X 52" long • Final Filter Modules: Airguard Variflow™ (or equal) - 24" X 24" X 12"

Model Number EPB-05-08-14 EPB-06-08-14 EPB-07-08-14

Reference Key

Cabin Dimensions I.D. Width Height Length

Part Opening Width Height

5’-0” 6’-0” 7’-0”

3’-0” 4’-0” 5’-0”

A

8’-0” 8’-0” 8’-0”

B

14’-0” 14’-0” 14’-0”

C

D

6’-0” 6’-0” 6’-0”

E

Operator Access Auto Manual 2 2 2

2 2 2

Total CFM 7,000 @ 4.5” SP 8,000 @ 4.5” SP 9,000 @ 4.5” SP

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Powder

LAB POWDER BOOTH LAB POWDER BOOTH WITH ROLLAWAY CASTER BASE

Control panel and VFD included

CONSTRUCTION FEATURES / ADVANTAGES •Streamlined modular design •Extremely quiet - less than 78 DBA •Top final filter discharge environmentally friendly •Easy-to-change airtight cartridge filters •Compact plenum design offers larger work area •Locking caster base

PANELS

Panels are fabricated from18-gauge prime quality stainless steel, flanged and precision punched on 6˝ centers for maximum rigidity. Panels are fastened together with 5/16˝ nuts and bolts, and are to be sealed with the provided caulk following assembly.

BASE ASSEMBLY

The rollaway base assembly cabinet and floor support is fabricated with 3˝ channel steel and formed 10-gauge mild steel (welded construction). The finish will be white powder coating.

CONTROL EQUIPMENT •PLC controlled •On-demand adjustable pulsing •Quick clean/purge mode •Manual pulse off switch •Circuit breaker protection •Air proving switch

OPTIONAL EQUIPMENT

•Optional air manifold

ILLUMINATION

Lighting is provided by Class I Division II, 48˝ long, fluorescent, 32-watt, T-8 type, four-tube fixture, mounted behind safety glass; appropriately sealed from the interior of the spray booth. All fixtures are UL listed and approved for their intended use and placement.

PLC BASED PURGE CONTROL

This feature assures the safe operation of the coatings enclosure, by maintaining the airflow at design levels. During operation overspray powder accumulates on the cartridge filters. As the cartridge filters load, airflow decreases and negative pressure rises within the air handler. A timer activates a system of air purging valves that clear the cartridge filters of accumulated powder to ensure maximum life.


Industrial

Powder

LAB POWDER BOOTH

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Truck

Wood

LIGHT DUTY CROSSDRAFT • ANGLED TOP LIGHTING • QUALITY DESIGN OPTIONS BOOTH SHOWN WITH CUSTOMIZATION

•UL Listed Control panel and other electric components can be purchased separately

•Industry-leading light levels

•Optional UL Listed Control Panel with VFD

•Quality brand-name tubeaxial fans and motors

•Spray booth specific, dual voltage T-8 32-watt light fixtures

•Air solenoid valve

•Windowed personnel access doors are pre-hung in a heavy gauge galvanized steel frame for easy installation. •Product doors are field hung on slotted hinges to facilitate installation on uneven floors

•Support Steel Constructed from 10 gauge, galvanized steel •All panels and 10 gauge support members are precision punched for easy nut and bolt assembly •5/16” bolt with self locking nuts for fastening panels every 6"

OVERVIEW

The Col-Met Light Duty Crossdraft Booth intakes fresh air through filters in the product doors. The clean, filtered air is drawn through the booth and exhausted through a filter system at the opposite end. This type of spray booth makes efficient use of shop space, and is available in solid back, drive through, and reverse flow designs.

LIGHTING FEATURES

Bright, full booth illumination is provided by 48" four-tube, 32-watt fluorescent light fixtures in the angled ceiling panels and side walls. All fixtures are UL listed and approved for their intended use and placement.

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Truck

Wood

LIGHT DUTY CROSSDRAFT

Model Number LDC-16-16-26-N-SB LDC-16-16-28-N-SB LDC-16-16-30-N-SB LDC-16-16-32-N-SB LDC-16-16-34-N-SB LDC-16-16-44-N-SB LDC-16-16-54-N-SB LDC-16-16-64-N-SB

Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Width Height Length Doors Width Height Qty Type S&G Open Total SCFM 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 14 15 25,600 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 14 15 25,600 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 17 18 25,600 16'-0" 16'-0" 32'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 17 18 25,600 16'-0" 16'-0" 34'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 19 20 25,600 16'-0" 16'-0" 44'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Filtered 2 26 28 25,600 16'-0" 16'-0" 54'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Filtered 3 31 34 25,600 16'-0" 16'-0" 64'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Filtered 4 38 42 25,600

Sizing Option Ranges: 14-20* 12-20*

^

Reference Key

C

A

B

D

E

Alternative Configurations: Reverse Flow (RF) Drive Through (DT) Alternative Options: Pressurized (P) *Standard Sizing of Width and Height are in Increaments of 2(ft) ^Standard Length Sizing is Illustrated above COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS

Fan Spec. Filters Dia. HP Int. Exh 42 7.5 48 48 42 7.5 48 48 42 7.5 48 48 42 7.5 48 48 42 7.5 48 48 42 7.5 48 48 42 7.5 48 48 42 7.5 48 48


Industrial

Truck

Wood

LIGHT DUTY MODIFIED DOWNDRAFT • ANGLED TOP LIGHTING • QUALITY DESIGN OPTIONS BOOTH SHOWN WITH PRESSURIZED INTAKE PLENUM & SQUARE-TOP DESIGN

•UL Listed Control panel and other electric components can be purchased separately

•Industry-leading light levels

•Optional UL Listed Control Panel with VFD

•Quality brand-name tubeaxial fans and motors

•Spray booth specific, dual voltage T-8 32-watt light fixtures

•Air solenoid valve

•Windowed personnel access •Support Steel Constructed from doors are pre-hung in a heavy 10 gauge, galvanized steel gauge galvanized steel frame •All panels and support members for easy installation. are precision punched for easy nut and bolt assembly •Product doors are field hung on slotted hinges to facilitate •5/16” bolt with self locking nuts installation on uneven floors for fastening panels every 6"

OVERVIEW

The Light Duty Modified Downdraft Booth intakes fresh air from the cleaner upper levels of the shop through a filter bank located in the booth ceiling near the product doors. The filtered air is drawn down through the booth to an exhaust filter system at the other end, and is optionally equipped with a pre-filter plenum for additional intake air filtration. The basic modified downdraft design allows for easy pressurization with the addition of an intake plenum with fan or a heated air make up unit.

LIGHTING FEATURES

Bright, full booth illumination is provided by four-tube, 48", 32-watt, fluorescent light fixtures in the angled ceiling panels and side walls. All fixtures are UL listed and approved for their intended use and placement.

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Truck

Wood

LIGHT DUTY MODIFIED DOWNDRAFT

Model Number LDM-16-16-26-N-SB LDM-16-16-28-N-SB LDM-16-16-30-N-SB LDM-16-16-32-N-SB LDM-16-16-34-N-SB LDM-16-16-44-N-SB LDM-16-16-54-N-SB LDM-16-16-64-N-SB

Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Width Height Length Doors Width Height Qty Type 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 32'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 34'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 44'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 54'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 64'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid

Sizing Option Ranges: 14-20* 12-20*

^

Reference Key

C

A

B

D

Illumination S&G Open Total 1 14 15 1 14 15 1 17 18 1 17 18 1 19 20 2 26 28 3 31 34 4 38 42

Air Flow SCFM 25,600 25,600 25,600 25,600 25,600 25,600 25,600 25,600

E

Alternative Configurations: Reverse Flow (RF) Drive Through (DT) Alternative Options: Pre-Filtered (PF) Pressurized (P) *Standard Sizing of Width and Height are in Increaments of 2(ft) ^Standard Length Sizing is Illustrated above COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS

Fan Spec. Dia. HP 42 7.5 42 7.5 42 7.5 42 7.5 42 7.5 42 7.5 42 7.5 42 7.5

Filters Int. Exh 42 48 42 48 42 48 42 48 42 48 42 48 42 48 42 48


Industrial

Truck

Wood

LIGHT DUTY SIDE DOWNDRAFT • ANGLED TOP LIGHTING • QUALITY DESIGN OPTIONS BOOTH SHOWN WITH CUSTOMIZATION

•UL Listed Control panel and other electric components can be purchased separately

•Industry-leading light levels

•Optional UL Listed Control Panel with VFD

•Quality brand-name tubeaxial fans and ODP motors

•Spray booth specific, dual voltage T-8 32-watt light fixtures

•Air solenoid valve

•Windowed personnel access •Support Steel Constructed from doors are pre-hung in a heavy 10 gauge, galvanized steel gauge galvanized steel frame •All panels and support members for easy installation. are precision punched for easy nut and bolt assembly •Product doors are field hung slotted hinges to facilitate •5/16” bolt with self locking nuts installation on uneven floors for fastening panels every 6"

OVERVIEW

The Light Duty Side Downdraft Booth intakes fresh air from the cleaner upper levels of the shop through a filtered booth ceiling. The filtered air is drawn down and away from the product through exhaust filters at the floor level, along both sides. This provides efficient overspray control that reduces prep time and also provides a much healthier workplace environment without an expensive downdraft exhaust pit. This booth can also be purchased with a pre-filtered plenum or with a pressurized intake plenum. The booth can also be equipped with an air replacement unit and cure cycle to meet your requirements. The Light Duty Side Downdraft Booth is available in either drive-through or solid back configurations.

LIGHTING FEATURES

Bright, full booth illumination is provided by four-tube, 48", 32-watt, fluorescent light fixtures in the angled ceiling panels and side walls. All fixtures are UL listed and approved for their intended use and placement. COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Truck

Wood

LIGHT DUTY SIDE DOWNDRAFT

Model Number LDS-16-16-26-N-SB LDS-16-16-28-N-SB LDS-16-16-30-N-SB LDS-16-16-40-N-SB LDS-16-16-50-N-SB LDS-16-16-60-N-SB

Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Width Height Length Doors Width Height Qty Type S&G Open Total SCFM 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 20,800 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 22,400 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 24,000 16'-0" 16'-0" 40'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 2 22 24 32,000 16'-0" 16'-0" 50'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 3 27 30 40,000 16'-0" 16'-0" 60'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid 4 34 36 48,000

Sizing Option Ranges:

14-20* 12-20*

Reference Key

A

B

^

C

D

E

Alternative Configurations: Drive Through (DT) Alternative Options: Pre-Filtered (PF) Pressurized (P) *Standard Sizing of Width and Height are in Increaments of 2(ft) ^Standard Length Sizing is Illustrated above COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS

Fan Spec. Dia. HP (2)30 (2)3 (2)30 (2)5 (2)30 (2)5 (4)24 (4)3 (4)30 (4)3 (4)30 (4)5

Filters Int. Exh 38 30 40 32 44 36 58 46 72 58 88 70


Industrial

Truck

Wood

LIGHT DUTY DOWNDRAFT • ANGLED TOP LIGHTING • QUALITY DESIGN OPTIONS BOOTH SHOWN WITH CUSTOMIZATION

•UL Listed Control panel and other electric components can be purchased separately

•Industry-leading light levels

•Optional UL Listed Control Panel with VFD

•Quality brand-name tubeaxial fans and motors

•Spray booth specific, dual voltage T-8 32-watt light fixtures

•Air solenoid valve

•Windowed personnel access •Support Steel Constructed from doors are pre-hung in a heavy 10 gauge, galvanized steel gauge galvanized steel frame •All panels and support members for easy installation. are precision punched for easy nut and bolt assembly •Product doors are field hung on slotted hinges to facilitate •5/16” bolt with self locking nuts installation on uneven floors for fastening panels every 6"

OVERVIEW

The Light Duty Downdraft Booth takes in fresh air from the cleaner upper levels of the shop, through a filtered booth ceiling. The filtered air is drawn down and away from the product through exhaust filters in the pit located in the floor. This provides efficient overspray control that reduces prep time and also provides a much healthier workplace environment. This booth can be purchased with a pre-filtered plenum or with a pressurized intake plenum. It can also be equipped with an air replacement unit and cure cycle to meet your requirements. The Light Duty Downdraft Booth is available in either drive-through or solid back configurations.

LIGHTING FEATURES

Bright, full booth illumination is provided by four-tube, 48", 32-watt fluorescent light fixtures in the angled ceiling panels and side walls. All fixtures are UL listed and approved for their intended use and placement. COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Truck

Wood

LIGHT DUTY DOWNDRAFT

Model Number LDD-16-16-26-N-SB LDD-16-16-28-N-SB LDD-16-16-30-N-SB LDD-16-16-40-N-SB LDD-16-16-50-N-SB LDD-16-16-60-N-SB

Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Width Height Length Doors Width Height Qty Type 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 40'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 50'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 60'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid

Sizing Option Ranges: 14-20* 12-20*

^

Reference Key

C

A

B

D

Illumination S&G Open Total 1 14 15 1 14 15 1 17 18 2 22 24 3 27 30 4 32 36

Air Flow Fan Spec. SCFM Dia. HP 20,800 42 7.5 22,400 42 10 24,000 42 10 32,000 (2)42 (2)7.5 40,000 (2)42 (2)7.5 48,000 (2)42 (2)10

E

Alternative Configurations: Drive Through (DT) Alternative Options: Pre-Filtered (PF) Pressurized (P) *Standard Sizing of Width and Height are in Increaments of 2(ft) ^Standard Length Sizing is Illustrated above COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS

Filters Int. Exh 38 26 40 28 44 30 58 40 72 50 88 60


Industrial

Truck

Wood

HEAVY DUTY CROSSDRAFT • HEAVY DUTY CONSTRUCTION • ANGLED TOP LIGHTING • QUALITY DESIGN OPTIONS BOOTH SHOWN WITH CUSTOMIZATION

•UL Listed Control panel and other electric components can be purchased separately

•Industry-leading light levels

•Optional UL Listed Control Panel with VFD

•Quality brand-name tubeaxial fans and motors

•Spray booth specific, dual voltage T-8 32-watt light fixtures

•Air solenoid valve

•Windowed personnel access doors are pre-hung in a heavy gauge galvanized steel frame for easy installation. •Product doors are field hung on slotted hinges to facilitate installation on uneven floors

•Support Steel Constructed from W6x9 beam steel •All panels and support members are precision punched for easy nut and bolt assembly •5/16” bolt with self locking nuts for fastening panels every 6"

OVERVIEW

The Col-Met Heavy Duty Crossdraft Booth intakes fresh air through filters in the product doors. The clean, filtered air is drawn through the booth and exhausted through a filter system at the opposite end. This type of spray booth makes efficient use of shop space, and is available in solid back, drive through and reverse flow designs.

LIGHTING FEATURES

Bright, full booth illumination is provided by 48" four-tube, 32-watt fluorescent light fixtures in the angled ceiling panels and side walls. All fixtures are UL listed and approved for their intended use and placement.

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Truck

Wood

HEAVY DUTY CROSSDRAFT

Model Number HDC-16-16-26-N-SB HDC-16-16-28-N-SB HDC-16-16-30-N-SB HDC-16-16-32-N-SB HDC-16-16-34-N-SB HDC-16-16-44-N-SB HDC-16-16-54-N-SB HDC-16-16-64-N-SB

Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Width Height Length Doors Width Height Qty Type S&G Open Total SCFM 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 14 15 25,600 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 14 15 25,600 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 17 18 25,600 16'-0" 16'-0" 32'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 17 18 25,600 16'-0" 16'-0" 34'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 19 20 25,600 16'-0" 16'-0" 44'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Filtered 2 26 28 25,600 16'-0" 16'-0" 54'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Filtered 3 31 34 25,600 16'-0" 16'-0" 64'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Filtered 4 38 42 25,600

Sizing Option Ranges: 14-20* 12-20*

^

Reference Key

C

A

B

D

E

Alternative Configurations: Reverse Flow (RF) Drive Through (DT) Alternative Options: Pressurized (P) *Standard Sizing of Width and Height are in Increaments of 2(ft) ^Standard Length Sizing is Illustrated above COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS

Fan Spec. Dia. HP 42 7.5 42 7.5 42 7.5 42 7.5 42 7.5 42 7.5 42 7.5 42 7.5

Filters Int. Exh 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48


Industrial

Truck

Wood

HEAVY DUTY MODIFIED DOWNDRAFT • HEAVY DUTY CONSTRUCTION • ANGLED TOP LIGHTING • QUALITY DESIGN OPTIONS BOOTH SHOWN WITH CUSTOMIZATION

•UL Listed Control panel and other electric components can be purchased separately

•Industry-leading light levels

•Optional UL Listed Control Panel with VFD

•Quality brand-name tubeaxial fans and motors

•Spray booth specific, dual voltage T-8 32-watt light fixtures

•Air solenoid valve

•Windowed personnel access doors are pre-hung in a heavy gauge galvanized steel frame for easy installation. •Product doors are field hung slotted hinges to facilitate installation on uneven floors

•Support Steel Constructed from W6x9 beam steel •All panels and support members are precision punched for easy nut and bolt assembly •5/16” bolt with self locking nuts for fastening panels every 6"

OVERVIEW

The Heavy Duty Modified Downdraft Booth intakes fresh air from the cleaner upper levels of the shop through a filter bank located in the booth ceiling near the product doors. The filtered air is drawn down through the booth to an exhaust filter system at the other end, and is optionally equipped with a pre-filter plenum for additional intake air filtration. The basic modified downdraft design allows for easy pressurization with the addition of an intake plenum with fan or a heated air make up unit.

LIGHTING FEATURES

Bright, full booth illumination is provided by four-tube, 48˝, 32-watt, fluorescent light fixtures in the angled ceiling panels and side walls. All fixtures are UL listed and approved for their intended use and placement.

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Truck

Wood

HEAVY DUTY MODIFIED DOWNDRAFT

Model Number HDM-16-16-26-N-SB HDM-16-16-28-N-SB HDM-16-16-30-N-SB HDM-16-16-32-N-SB HDM-16-16-34-N-SB HDM-16-16-44-N-SB HDM-16-16-54-N-SB HDM-16-16-64-N-SB

Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Width Height Length Doors Width Height Qty Type S&G Open Total SCFM 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 25,600 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 25,600 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 25,600 16'-0" 16'-0" 32'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 25,600 16'-0" 16'-0" 34'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 19 20 25,600 16'-0" 16'-0" 44'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 2 26 28 25,600 16'-0" 16'-0" 54'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 3 31 34 25,600 16'-0" 16'-0" 64'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid 4 38 42 25,600

Sizing Option Ranges: 14-20* 12-20*

^

Reference Key

C

A

B

D

E

Alternative Configurations: Reverse Flow (RF) Drive Through (DT) Alternative Options: Pre-Filtered (PF) Pressurized (P) *Standard Sizing of Width and Height are in Increaments of 2(ft) ^Standard Length Sizing is Illustrated above COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS

Fan Spec. Filters Dia. HP Int. Exh 42 7.5 42 48 42 7.5 42 48 42 7.5 42 48 42 7.5 42 48 42 7.5 42 48 42 7.5 42 48 42 7.5 42 48 42 7.5 42 48


Industrial

Truck

Wood

HEAVY DUTY SIDE DOWNDRAFT • HEAVY DUTY CONSTRUCTION • ANGLED TOP LIGHTING • QUALITY DESIGN OPTIONS BOOTH SHOWN WITH CUSTOMIZATION

•UL Listed Control panel and other electric components can be purchased separately

•Industry-leading light levels

•Optional UL Listed Control Panel with VFD

•Quality brand-name tubeaxial fans and motors

•Spray booth specific, dual voltage T-8 32-watt light fixtures

•Air solenoid valve

•Windowed personnel access doors are pre-hung in a heavy gauge galvanized steel frame for easy installation. •Product doors are field hung on slotted hinges to facilitate installation on uneven floors

•Support Steel Constructed from W6x9 beam steel •All panels and support members are precision punched for easy nut and bolt assembly •5/16” bolt with self locking nuts for fastening panels every 6"

OVERVIEW

The Heavy Duty Side Downdraft Booth intakes fresh air from the cleaner upper levels of the shop through a filtered booth ceiling. The filtered air is drawn down and away from the product through exhaust filters at the floor level, along both sides. This provides efficient overspray control that reduces prep time and also provides a much healthier workplace environment without an expensive downdraft exhaust pit. This booth can also be purchased with a pre-filtered plenum or with a pressurized intake plenum. The booth can also be equipped with an air replacement unit and cure cycle to meet your requirements. The Heavy Duty Side Downdraft Booth is available in either drive-through or solid back configurations.

LIGHTING FEATURES

Bright, full booth illumination is provided by four-tube, 48", 32-watt, fluorescent light fixtures in the angled ceiling panels and side walls. All fixtures are UL listed and approved for their intended use and placement. COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Truck

Wood

HEAVY DUTY SIDE DOWNDRAFT

Model Number HDS-16-16-26-N-SB HDS-16-16-28-N-SB HDS-16-16-30-N-SB HDS-16-16-40-N-SB HDS-16-16-50-N-SB HDS-16-16-60-N-SB

Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Width Height Length Doors Width Height Qty Type S&G Open Total SCFM 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 20,800 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 22,400 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 24,000 16'-0" 16'-0" 40'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 2 22 24 32,000 16'-0" 16'-0" 50'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 3 27 30 40,000 16'-0" 16'-0" 60'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid 4 34 36 48,000

Sizing Option Ranges:

14-20* 12-20*

Reference Key

A

B

^

C

D

E

Alternative Configurations: Drive Through (DT) Alternative Options: Pre-Filtered (PF) Pressurized (P) *Standard Sizing of Width and Height are in Increaments of 2(ft) ^Standard Length Sizing is Illustrated above COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS

Fan Spec. Dia. HP (2)30 (2)3 (2)30 (2)5 (2)30 (2)5 (4)24 (4)3 (4)30 (4)3 (4)30 (4)5

Filters Int. Exh 38 30 40 32 44 36 58 46 72 58 88 70


Industrial

Truck

Wood

HEAVY DUTY DOWNDRAFT • HEAVY DUTY CONSTRUCTION • ANGLED TOP LIGHTING • QUALITY DESIGN OPTIONS BOOTH SHOWN WITH CUSTOMIZATION

•UL Listed Control panel and other electric components can be purchased separately

•Industry-leading light levels

•Optional UL Listed Control Panel with VFD

•Quality brand-name tubeaxial fans and motors

•Spray booth specific, dual voltage T-8 32-watt light fixtures

•Air solenoid valve

•Windowed personnel access doors are pre-hung in a heavy gauge galvanized steel frame for easy installation. •Product doors are field hung slotted hinges to facilitate installation on uneven floors

•Support Steel Constructed from W6x9 beam steel •All panels and support members are precision punched for easy nut and bolt assembly •5/16” bolt with self locking nuts for fastening panels every 6"

OVERVIEW

The Heavy Duty Downdraft Booth takes in fresh air from the cleaner upper levels of the shop, through a filtered booth ceiling. The filtered air is drawn down and away from the product through exhaust filters in the pit located in the floor. This provides efficient overspray control that reduces prep time and also provides a much healthier workplace environment. An optional above ground basement exhaust plenum is available for installation without concrete work. This booth can be purchased with a pre-filtered plenum or with a pressurized intake plenum. It can also be equipped with an air replacement unit and cure cycle to meet your requirements. The Heavy Duty Downdraft Booth is available in either drive-through or solid back configurations.

LIGHTING FEATURES

Bright, full booth illumination is provided by four-tube, 48", 32-watt fluorescent light fixtures in the angled ceiling panels and side walls. All fixtures are UL listed and approved for their intended use and placement.

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


Industrial

Truck

Wood

HEAVY DUTY DOWNDRAFT

Model Number HDD-16-16-26-N-SB HDD-16-16-28-N-SB HDD-16-16-30-N-SB HDD-16-16-40-N-SB HDD-16-16-50-N-SB HDD-16-16-60-N-SB

Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Width Height Length Doors Width Height Qty Type 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 40'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 50'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 16'-0" 16'-0" 60'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid

Sizing Option Ranges: 14-20* 12-20*

^

Reference Key

C

A

B

D

Illumination S&G Open Total 1 14 15 1 14 15 1 17 18 2 22 24 3 27 30 4 32 36

Air Flow SCFM 20,800 22,400 24,000 32,000 40,000 48,000

E

Alternative Configurations: Drive Through (DT) Alternative Options: Pre-Filtered (PF) Pressurized (P) *Standard Sizing of Width and Height are in Increaments of 2(ft) ^Standard Length Sizing is Illustrated above COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS

Fan Spec. Dia. HP 42 7.5 42 10 42 10 (2)42 (2)7.5 (2)42 (2)7.5 (2)42 (2)10

Filters Int. Exh 38 26 40 28 44 30 58 40 72 50 88 60


COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS



OVEN PANELS CONSTRUCTION FEATURES AND QUALITY DETAILS • Tongue and groove construction. • 4” thick panels constructed of 20-gauge prime aluminized steel inside and out. Both panel surfaces are roll-formed for uniformity. • 2", 3", 6", and 8" thick panels are also available. • Stiffener panels comprising the top, bottom and sidewalls of the panels are factory-punched to reduce the through metal, thereby reducing heat transmission to the exterior surface of the panels. • Col-Met utilizes a “Knuckle” punch for attachment of the top and bottom connecting panels and a “Button” punch along the tongue and groove surfaces, instead of spot welds which are known to breakdown the panel integrity. This assembly process provides superior strength while protecting the cosmetic appearance of the panels. • Where possible, standard 27-1/2" panels are used - providing a net width of 26". (36" width optional) • Standard 4 lb. density semi-rigid/resilient Rockwool insulation sandwiched between surfaces. (6 and 8 lb. density optional) • Available in lengths up to 15', as well as custom lengths upon request. • Powder Coated White finish is available as an option.

SHIPPING • Most orders ship in 2 weeks or less. • Panels are placed on their edges, palletized, and secured with 2x4 banded reinforced framing for forklift unloading.

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


UL CONTROL PANELS • NEMA 12 Enclosure • Non-Fused Disconnect • Starters with Overload Disconnect • Two-Position Selector Switches • Fire Protection Interlock Shipped pre-wired by Col-Met for easy and accurate hookup. Panel controls the exhaust fan and light operation of the spray booth. Panel includes a NEMA 12 enclosure, main disconnect switch, magnetic motor starter with overload disconnect and operative On/Off switch with fire protection interlock. Control Panels are designed for three (3) phase and single (1) phase operations. Consult your factory representative for further information. Not recommended for Col-Met Spray Booths featuring air make-up units, air balancing systems and / or infrared heaters.

All control panels fabricated by Col-Met Spray Booths are UL Listed. Col-Met is a UL 508-A certified shop.

OPTIONS / CUSTOM PANELS • • • •

VFDs Magnahelic Photohelic Lighting Contactor

COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS


TUBEAXIAL BELT DRIVEN FAN PERFORMANCE

• Airflow from 580 to 30,000 CFM • Static pressure 0˝ to 1.25˝ w.g. • AMCA certified

SIZE

• Belt driven sizes 12˝ to 42˝ diameters

Fan Specifications

*dBA subject to change depending on actual application

Fan Diameter

SCFM @1/2" SP

12" 18" 24" 30" 36" 42"

Motor HP

Motor RPM

Fan RPM

3/4 1450 1725 2457 3/4-1-1/2 1030-5000 1725 1245-2460 1-3 5350-9050 1725-1750 1330-1960 2-5 8850-15000 1750 1035-1500 5 15296-18392 1750 860-979 5-10 20263-32457 1750 830-1156

APPLICATIONS

These tubeaxial fans are specifically designed for continuous duty, cost effective and reliable air movement in commercial and light industrial ducted and non-ducted applications.

FEATURES

• Aluminum non-sparking fan blade meets all NFPA 33 requirements • Continuously welded, heavy-gauge, corrosion resistant, enamel coated steel housing • Heavy-gauge steel motor and bearing supports provide maximum strength with minimal resistance to airflow • Flanged housings with prepunched mounting holes can easily be connected to ductwork • Motor supports are constructed of heavy-gauge galvanized steel • Dynamically balanced propellers for quiet, vibration-free operation • Cast iron motor sheaves. Drives and belts are rated for a minimum of 150% of the required motor HP. • All units are factory tested prior to shipment. Propellers are statically and dynamically balanced in accordance with ANSI/AMCA 204-96.

AERODYNAMIC BELT TUBE WITH STANDARD ACCESS DOOR

MAINTENANCE-FREE BEARING ASSEMBLY

dBA @5'

85 80-90 88-96 84-92 87-89 89-98


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.