The installation of multiple fans is possible. These are individually controlled by flow meters mounted on a fan standard control panel. An example is shown in Figure 4.18. The liquid pump is located at ground level near the premix container of Ecosorb速 and the product is pumped up to the fan(s). The engineer needs to pay attention to liquid pressure losses due to fan elevation and line length, especially if specifying a pump other than an electronic chemical metering pump. Each fan assembly has a drain line connection on the guard shroud for return condensate. This low volume of waste should be properly plumbed and disposed.

To Fans

Water Inlet

Ecosorb速 606

Figure 4.18: Multi-Fan Control Panel

Section 4: Odor Control Equipment