EXIN LIGHT ANTIEXPLOSIVO

Page 1

Exin light - antiexplosiva

R E N TA L E Q U I PA M I E N TO I N D U S T R I A L S E RV I C I O S

luminarias autรณnomas portรกtiles a prueba de explosiones

Representantes exclusivos de :

Ex & Industrial Lighting


Iluminación a prueba de explosiones EX - Gama de iluminación portátil Modelos: EX90L T4 IIB 720 DS • EX90L T4 IIB 1440 SS • EX90L T4 IIC 720 SS Certificaciones: IECEx Certificate No: IECEx TSA 15.0025X • ATEX Certificate No: ITS16ATEX28430X

Los productos Exin Light Explosion Proof llevan la clasificación T4 y han sido aprobados y certificados por las autoridades competentes: TestSafe Australia para el Certificado IECEx e Intertek UK para la certificación ATEX. Estas certificaciones proporcionan evidencia de que las luces EXIN son adecuadas para áreas donde hay gases inflamables y polvos combustibles, siempre y cuando su requerimiento esté dentro de la clasificación certificada de nuestros tres modelos.

CUERPO El cuerpo EX90L se construye utilizando una resina automotriz tipo ABS747 que hace que la luminaria sea altamente duradera para su uso en la minería, plataformas petroleras y en industrias donde podría haber gas inflamable u otra atmósfera potencialmente explosiva. La goma amortiguadora en la base y la tapa, proporcionan una protección adicional, y los brazos de extensión ajustables en altura incorporados hacen que esta luz sea adecuada para todas las tareas.

BATERÍA La batería que se utiliza en los modelos EXIN Light Explosion Proof es una batería Ni-MH encapsulada. No necesita agua ni servicio y sólo se debe cargar de acuerdo con las instrucciones proporcionadas.

ESPECIFICACIONES Modelo Peso Altura Abierta (mm) Altura Cerrada (mm) Ancho (mm) Profundidad (mm) Voltaje de carga AC Batería Tipo de luz

Lúmenes Protección de ingreso Temperatura ambiente clasificada Tiempo de carga de la batería (hrs) Tiempo de ejecución de la batería (hrs)

T4 IIB 720 DS 8kg

T4 IIB 1440 SS T4 IIC 720 SS 8kg 7.8kg 880mm 570mm 330mm 200mm 110 o 240 VAC a 12 VDC max 2A 9.6 Paquete de baterías Ni-MH (que contiene 8 células selladas) Exin EX96B LED de alta intensidad 720 Bajo (Un lado) 720 en cada lado 720 Un lado 1440 Alto (Un lado) IP65 (-20ºC ≤ Tamb ≤ +40ºC) 7-8 10-12 Un lado 5-6 en alto 10-12 5-6 Usando ambos lados 10-12 en bajo

AT Australian Made & Designed.

Representados por:

Ex & Industrial Lighting

R E N TA L E Q U I PA M I E N TO I N D U S T R I A L S E RV I C I O S


Certifi caciones


Certi fi caciones


Certi fi caciones Safety Data Sheet – EXB001 Product identifier & identity for the chemical Product Identifier: Rechargeable NiMH Battery Packs (All models) Other means of identification: Model EX-96-xx Recommended use of the chemical and restrictions on use: Nil Suppliers name & address: Unit 7, 1 Reliance Drive, Tuggerah NSW Australia Phone number: +61 243 554 577

Emergency phone number: Within USA & Canada call: +1-800-424-9300 (GP Batteries)

Outside USA and Canada call: +1-703-527-3887 (GP Batteries)

Hazard Identification GHS Classification: N.A. Label elements, including precautionary statements: Do not short circuit outputs Do not use if the outer casing is damaged Only use with charger supplied with unit Not to come in contact with acid Under normal conditions of use, the battery is hermetically sealed and encapsulated. If the electrolyte leaks, hazardous material may be released. Human Health Effects Inhalation:

The electrolyte inhalation can cause respiratory irritation. It could be a possible carcinogen.

Skin contact:

The electrolyte can cause skin irritation, chemical burns. Nickel compounds, cobalt and cobalt compounds can cause skin sensitization and an allergic contact dermatitis.

Eye contact:

The electrolyte leaked from the battery cell is strong alkali, can cause severe irritation and chemical burns

Ingestion :

If the battery is swallowed and opened, or the electrolyte is ingested, the electrolyte irritates the mouth and the throat seriously, may lead to vomiting, nausea, hematemesis, stomach pains and diarrhoea.

First Aid Measures Inhalation

If electrolyte leakage occurs, cover the victimainblanket, move to the place of fresh air and keep quiet. Seek medical attention immediately. When dyspnea (breathing difficulty) or asphyxia (breath-hold), give artificial respiration immediately.

Skin Contact

If electrolyte leakage occurs, remove contaminated clothes and shoes immediately. Wash the adherence or contact region with soap and plenty of water. Seek medical attention immediately.

Eye Contact

If electrolyte leakage occurs, immediately flushes eywith water continuously for at least 15 minutes. Seek medical attention immediately.

Ingestion

If battery cell and electrolyte is ingested, do not induce vomiting or give food or drink. Seek medical attention immediately.


R E N TA L E Q U I PA M I E N TO I N D U S T R I A L S E RV I C I O S

CONTACTOS (01) 719-6010 | contacto@lfbrental.pe | www.lfbrental.pe | | Panamericana Sur Km 29.5 - Complejo Industrial Megacentro Lurín (Bloque A - Almacén 7)


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.