OSRAM LED SubstiTUBE® T8 Advanced
01
FULL GLASS
OSRAM LED SubstiTUBE® T8 Advanced 220-240 V for CCG Product name
ST8A 2ft 9W 865 G13 EM ST8A 2ft 9W 840 G13 EM ST8A 4ft 18W 865 G13 EM ST8A 4ft 18W 840 G13 EM ST8A 5ft 21W 865 G13 EM ST8A 5ft 21W 840 G13 EM ST8A 4ft 16W 865 G13 HE ST8A 4ft 16W 840 G13 HE ST8A 4ft 22W 865 G13 HO ST8A 4ft 22W 840 G13 HO Product name
GTIN (EAN)
4058075034174 4058075034198 4058075034211 4058075034235 4058075034259 4058075034273 4058075034297 4058075034310 4058075034334 4058075034358
ST8A 2ft 9W 865 G13 EM ST8A 2ft 9W 840 G13 EM ST8A 4ft 18W 865 G13 EM ST8A 4ft 18W 840 G13 EM ST8A 5ft 21W 865 G13 EM ST8A 5ft 21W 840 G13 EM ST8A 4ft 16W 865 G13 HE ST8A 4ft 16W 840 G13 HE ST8A 4ft 22W 865 G13 HO ST8A 4ft 22W 840 G13 HO Product features — LED alternative to classic T8 fluorescent linear lamps in CCG luminaires — Bright, robust and durable — Uniform illumination — Lifetime up to 50000 hrs — Single and tandem operation on conventional control gear (0.6 m version) — Glass tube with polycarbonate end-cap — Mercury-free and RoHS compliant — Type of protection: IP20 — High color stability (SDCM ≤ 5) — Integrated ECG with high power factor Product benefits — Quick, simple and safe replacement without rewiring — Energy savings of up to 60% (compared to T8 fluorescent lamp on CCG) — Instant-on light, therefore ideally suitable in combination with sensor technology — Very high resistance to switching loads — Also suitable for operation at low temperatures
2ft 2ft 4ft 4ft 5ft 5ft 4ft 4ft 4ft 4ft
9 9 18 18 21 21 16 16 22 22
1000 1000 2100 2100 2400 2400 2200 2200 2600 2600
110 110 110 110 110 110 130 130 115 115
6500 4000 6500 4000 6500 4000 6500 4000 6500 4000
>210° >210° >210° >210° >210° >210° >210° >210° >210° >210°
83 83 83 83 83 83 83 83 83 83
50000 50000 50000 50000 50000 50000 50000 50000 50000 50000
220V-240V 220V-240V 220V-240V 220V-240V 220V-240V 220V-240V 220V-240V 220V-240V 220V-240V 220V-240V
01 01 01 01 01 01 01 01 01 01
Areas of application — General illumination within ambient temperatures from –20…+50 °C — Illumination of production areas — Traffic zones and corridors — Supermarkets and department stores — Industry — Hospitality — Education Equipment / Accessories — Suitable for operation with low-loss and conventional control gears Safety advice — Not suitable for operation with electronic control gear — Operation in outdoor applications in suitable damp-proof luminaires possible according to data sheet and installation instruction Legal advice — When used to replace a T8 fluorescent lamp the total energy efficiency and light distribution depends on the design of the lighting system