6.4.1 Clip or Tie Wrap Installation Method

CAUTION

Fasten the power cable to the truck body. Locate one fastener (battery side) within three inches of the end of the fuse assembly. Locate the other fastener (power unit side) within eight inches of the fuse assembly.

Using the direct battery wiring connection is not recommended because it does not remove power to the liftgate when the truck is left unattended. A cut-off switch or cut-off solenoid will prevent the unauthorized use of the liftgate when the truck is not in use.

TO LIFTGATE

LIFTGATE SOLENOID LONG POWER CABLE

Approx.3"

200 AMP FUSE

VEHICLE BATTERY + –

GROUND ALI-00116

Approx. 8" A-1073

Power cable connected directly from power unit to battery.

1. Position the fuse assembly near the battery so the short cable end will reach the positive (+) terminal.

6.4.2 Bolt-On Method

2. Attach the fuse holder to the truck body using either “6.4.1 Clip or Tie Wrap Installation Method” on page 25 or “6.4.2 Bolt-On Method” on page 25. 3. Route the long end of the power cable from the fuse to the motor solenoid in the liftgate pump compartment. If the power cable is longer than required, cut it to the desired length and attach a cable lug according to instructions in “6.3 Cable Lug Installation” on page 24.

Approx.6" Approx.6"

4. Connect the power cable to the motor solenoid. Make sure the power cable is connected to the correct motor solenoid post (the one not connected to the motor housing with a metal strap or wire cable). A-1074

1. Attach the fuse holder to the truck body using #10 or #12 self-tapping screws or bolts, washers, and selflocking nuts. 2. Fasten the power cable, as needed, to properly hold it in place. 3. Using this method requires an extra length of cable on one side of the fuse assembly to permit removal of the fuse.

6.5

Direct Battery Connection Option

This method is not recommended because it allows the unauthorized use of the liftgate when the truck is unattended. To prevent unauthorized use, use either “6.6 Cut-Off Solenoid Connection Option” on page 26 or “6.7 Cut-Off Switch Connection Option” on page 26.

5. Connect the short end of the power cable to the positive post of the battery. 6. The power unit should now be operational. 7. Coat all terminal ends, studs, and nuts with a Teflon lubricant, grease, or other electrical connection sealant to prevent corrosion.

L-501 Models 800-482-0003