parte 2 mpc4000

Page 177

System Service Mode 022 Thick Paper: Standby: L

[Capacitor Condition Display] Not used

001 Latest Capacity

*ENG

[0 to 150 / 45 / 1 F/step]

002 Current Voltage

*ENG

[0 to 50 / 0 / 0.01 V/step]

003 Charge Time

*ENG

[0 to 50000 / 0 / 10 ms/step]

004 Deterioration Counter

*ENG

[0 to 1000 / 0 / 1 /step]

005 Charge Current

*ENG

[5 to 15 / 10 / 0.1 A/step]

1913

[Capacitor Discharge Stop Voltage Setting] Not used

001 -

1914

[10 to 25 / 20 / 1 V/step]

[Capacitor Deterioration Detection Condition] Not used

001 AC Input Voltage Display

*ENG

[0 to 150 / 100 / 1 V/step]

002 Deterioration Counter

*ENG

[10 to 250 / 30 / 1 /step]

003 AC Input Voltage

*ENG

[80 to 100 / 90 / 1 V/step]

004 Capacitor Capacity

*ENG

[20 to 130 / 35 / 1 F/step]

011 Offset: Plain: Ready

*ENG

[0 to 50 / C2c: 35, C2d: 30 / 1 deg/step]

012 Offset: Plain: Standby

*ENG

[0 to 50 / 5 / 1 deg/step]

*ENG

[0 to 50 / C2c: 30, C2d: 25 / 1 deg/step]

*ENG

[0 to 50 / 5 / 1 deg/step]

1915

013

014

SM

*ENG

[After Ready Setting]

Offset: Middle Thick: Ready Offset: Middle Thick: Standby

8-23

D027/D029 APPENDICES

Appendix SP Mode Tables

1912

*ENG