Working Drawings || JH Designs

Page 1

HEINRICH

D E S I G N S

TECHNICAL DRAWINGS

JENNIFER


OFFICE


COPYRIGHT RESERVED: This drawing and design are, and at all times remain, the exclusive property of Jennifer Heinrich, and can be reproduced only with written consent. This drawing must not be scaled. Contractors shall verify all dimensions prior to commencement of work, and any omissions or discrepancies shall be reported to the Designer.

MARKET RESEARCH GROUP S U I T E 2 5 0, 6 5 0 W 4 1 S T A V E, V A N C O U V E R, B C V 5 Z 2 M 9

SITE LOCATION

JH|DESIGNS

ISSUE NO.

ISSUED FOR:

1.

PHASE ONE REVISION INITIALS XXXX

2.

PHASE TWO REVISION INITIALS XXXX

revision

description

BY:

DATE:

980 EAST 50TH AVENUE V A N C O U V E R, B C V 5 X 1 B 5 (780) 270-4710

LOCATION PLAN SCALE: NTS

by

date

JH|DESIGNS 1090 W.GEORGIA ST. VANCOUVER, BC V6E 3V7 TEL. (604) 270 - 4710

GENERAL NOTES

TABLE OF CONTENTS

PROJECT:

ID-000 ID-001 ID-002 ID-003 ID-004 ID-005 ID-006 ID-007 ID-008 ID-009 ID-010 ID-011 ID-012

TITLE PAGE DEMOLITION PAGE DEMOLITION NOTES CONSTRUCTION PLAN LIGHTING SCHEDULE DOOR SCHEDULE REFLECTED CEILING PLAN FINISHES PLAN FURNITURE PLAN FURNITURE SPECIFICATION ELEVATIONS: KITCHEN & RECEPTION DESK SECTIONS DETAIL DRAWINGS

·

ALL WORKMANSHIP AND METHODS OF CONSTRUCTION TO MEET REQUIREMENTS OF THE CURRENT EDITION OF THE BRITISH COLUMBIA BUILDING CODE AND CITY OF VANCOUVER BYLAWS

·

CONTRACTOR TO CONFIRM DIMENSIONS ON SITE PRIOR TO COMMENCING CONSTRUCTION. DISCREPANCIES TO BE REPORTED TO THE DESIGNER PRIOR TO PROCEEDING.

·

WRITTEN DIMENSIONS TO TAKE PRECEDENCE OVER SCALED DIMENSIONS REMOVED MATERIAL AND PRODUCTS TO BE DISPOSED OF OR SALVAGED AS DIRECTED BY OWNER

·

ACCESS TO SITE AND WORK SCHEDULE TO BE COORDINATED WITH DESIGNER

·

KEEP SITE CLEAN AND MAINTAIN SAFETY OF PUBLIC DURING DEMOLITION, CONSTRUCTION. BLOCK AND BRACE AS REQUIRED

·

ALL MATERIALS SHOULD ARRIVE ON SITE IN ORIGINAL PACKAGING

·

CONTRACTOR MUST CHECK THE CONDITION OF MATERIALS UPON DELIVERY

·

USE ONLY MOST REVISED DRAWINGS

·

REPORT ALL ERRORS OR OMISSIONS TO THE DESIGNER, ARCHITECT OR ENGINEER

MARKET RESEARCH GROUP 7785 WEST HASTINGS STREET VANCOUVER, BC

TITLE:

TITLE PAGE

NOTE:

·

·

SITE MEASUREMENTS REQUIRED. ALL CONTRACTORS SHALL VERIFY ON-SITE CONDITIONS, DIMENSIONS, DRAWINGS, DETAILS AND SPECIFICATIONS AND REPORT ALL ERRORS AND OMISSIONS TO THE DESIGNER BEFORE PROCEEDING WITH WORK. DO NOT SCALE THE DRAWINGS. THESE DRAWINGS REMAIN THE PROPERTY OF THE DESIGNER.

DATE:

AUGUST 6, 2015

SCALE:

NTS

DRAWN BY:

JENNIFER HEINRICH

DRAWING NO.

ID-000


COPYRIGHT RESERVED: This drawing and design are, and at all times remain, the exclusive property of Jennifer Heinrich, and can be reproduced only with written consent. This drawing must not be scaled. Contractors shall verify all dimensions prior to commencement of work, and any omissions or discrepancies shall be reported to the Designer.

1 2 4 3

5

1 6 2 4 3

PIPE CHASE

C O N S T R U C T I O N L E G E ND DEMOLISHED WALLS CONSTRUCTION WALLS PIPE

1 2 4 3

EXISTING WALLS

CHASE

CHASE

·

·

PIPE

1 2 4 3

·

·

PIPE

1 6 2 4 3

· · · ·

1.

PHASE ONE REVISION INITIALS XXXX

2.

PHASE TWO REVISION INITIALS XXXX

revision

description

BY:

DATE:

ALL WORKMANSHIP AND METHODS OF CONSTRUCTION TO MEET REQUIREMENTS OF THE CURRENT EDITION OF THE BRITISH COLUMBIA BUILDING CODE AND CITY OF VANCOUVER BYLAWS CONTRACTOR TO CONFIRM DIMENSIONS ON SITE PRIOR TO COMMENCING CONSTRUCTION. DISCREPANCIES TO BE REPORTED TO THE DESIGNER PRIOR TO PROCEEDING. WRITTEN DIMENSIONS TO TAKE PRECEDENCE OVER SCALED DIMENSIONS REMOVED MATERIAL AND PRODUCTS TO BE DISPOSED OF OR SALVAGED AS DIRECTED BY OWNER ACCESS TO SITE AND WORK SCHEDULE TO BE COORDINATED WITH DESIGNER KEEP SITE CLEAN AND MAINTAIN SAFETY OF PUBLIC DURING DEMOLITION, CONSTRUCTION. BLOCK AND BRACE AS REQUIRED ALL MATERIALS SHOULD ARRIVE ON SITE IN ORIGINAL PACKAGING CONTRACTOR MUST CHECK THE CONDITION OF MATERIALS UPON DELIVERY USE ONLY MOST REVISED DRAWINGS REPORT ALL ERRORS OR OMISSIONS TO THE DESIGNER, ARCHITECT OR ENGINEER

by

date

JH|DESIGNS 1090 W.GEORGIA ST. VANCOUVER, BC V6E 3V7 TEL. (604) 270 - 4710

NOTE:

·

CHASE

1 2 4 3

SITE MEASUREMENTS REQUIRED. ALL CONTRACTORS SHALL VERIFY ON-SITE CONDITIONS, DIMENSIONS, DRAWINGS, DETAILS AND SPECIFICATIONS AND REPORT ALL ERRORS AND OMISSIONS TO THE DESIGNER BEFORE PROCEEDING WITH WORK.

·

DO NOT SCALE THE DRAWINGS. THESE DRAWINGS REMAIN THE PROPERTY OF THE DESIGNER.

·

GENERAL CONTRACTOR TO VISIT SITE PRIOR TO PRICING AND CONSTRUCTION TO DETERMINE EXTENT OF EXISTING T-BAR CEILING AND ACOUSTIC TILE TO BE REMOVED AND/OR DEMOLISHED TO ACCOMMODATE NEW CONSTRUCTION.

·

PROJECT:

MARKET RESEARCH GROUP 7785 WEST HASTINGS STREET VANCOUVER, BC

ALL CEILING COMPONENTS AND MECHANICAL/ ELECTRICAL DEVICES TO BE INSTALLED TO SEISMIC REQUIREMENTS OF BC.

· PIPE

6

CHASE

·

5

ISSUED FOR:

GENERAL NOTES

PIPE CHASE

5

ISSUE NO.

·

CEILING HEIGHTS AS NOTED ON ELEVATIONS

·

SEE PAGES ID-002 FOR DEMOLITION NOTES

ID-001 1

TITLE:

DEMOLITION PLAN

DEMOLITION PLAN SCALE: 1/4" = 1'-0"

DATE:

AUGUST 6, 2015

SCALE:

1/4" = 1'-0"

DRAWN BY:

JENNIFER HEINRICH

DRAWING NO.

ID-001


DEMOLITION & CONSTRUCTION GENERAL NOTES PLAN DEMOLITION GENERAL NOTES: -

-

-

-

-

THE INTENT OF THE DEMOLITION WORK IS TO PROVIDE A CLEAR AREA FOR NEW CONSTRUCTION. ALL DEMOLITION WORK MUST BE PERFORMED IN CONFORMANCE TO CITY OF VANCOUVER, BC - CURRENT EDITION WALLS, PARTITIONS, DOORS, WINDOWS, MILLWORK, FIXTURES, FINISHES & CEILINGS ARE TO BE REMOVED TO FACILITATE NEW WORK, EXCEPT WHERE INDICATED OTHERWISE ON THE PLAN OR WHERE IT MAY IMPACT ADJACENT AREAS OUTSIDE OF THE RENOVATION. ITEMS KEY NOTED ARE INTENDED TO ASSIST THE CONTRACTOR IN IDENTIFYING SPECIFIC CONDITIONS. DEMOLITION WORK IS NOT LIMITED TO ITEMS TAGGED. CONTRACTOR SHALL CONFIRM SITE CONDITIONS PRIOR TO START ON WORK, AND NOTIFY THE DESIGNER OF DISCREPANCIES WHICH MAY AFFECT THE WORK OR IMPACT THE FUNCTION OF THE PROJECT IN AREAS OUTSIDE OF THE CONSTRUCTION ZONE. CONTRACTOR TO COORDINATE ALL DEMOLITION WORK WITH ALL TRADES. REFER TO MECHANICAL & ELECTRICAL DRAWINGS & SPECIFICATIONS FOR COMPLETE SCOPE OF DEMOLITION AND NEW WORK

-

VERIFY WITH [OWNER] ALL ITEMS TO BE SALVAGED PRIOR TO START OF DEMOLITION.

-

PATCH, REPAIR & REPAINT ALL EXISTING BUILDING FINISHES OR COMPONENTS OUTSIDE OF CONSTRUCTION AREA WHICH ARE DAMAGED BY RELATED CONSTRUCTION ACTIVITY, INCLUDING DAMAGE CAUSED BY MOVEMENT OF MATERIALS IN CORRIDORS.

-

EXISTING PARTITIONS ARE TYPICALLY GYPSUM BOARD ON METAL STUD EXTENDING TO U/S OF STRUCTURE.

PLAN DEMOLITION KEY NOTES:

1 2 3

REMOVE EXISTING MILLWORK, SHELVING AND PLUMBING FIXTURES. PATCH AND MAKE GOOD EXISTING PARTITION.

4

REMOVE EXISTING VINYL FLOORING & RUBBER BASE. PREP CONCRETE SLAB FOR NEW FLOOR FINISH. REFER TO SPEC. COORDINATE WITH EXTENT OF NEW FLOORING FINISHES.

5

REMOVE EXISTING INTERIOR DOOR AND WINDOWS AND THEIR CORRESPONDING FRAMES. PATCH AND MAKE GOOD REMAINING PARTITION TO SUIT NEW PLAN AS REQUIRED.CUT EXISTING WALL AS REQUIRED TO SUIT NEW DOOR OPENING

6

GENERAL NOTES:

REMOVE EXISTING GYPSUM BOARD PARTITION INCLUDING ALL PROTECTION, RAILS & ELEC./ MECH. DEVICES. MAKE GOOD AND FINISH REMAINING WALL PROTECTION ADJACENT TO DEMOLITION WORK. FINISH TO MATCH EXISTING.

COPYRIGHT RESERVED: This drawing and design are, and at all times remain, the exclusive property of Jennifer Heinrich, and can be reproduced only with written consent. This drawing must not be scaled. Contractors shall verify all dimensions prior to commencement of work, and any omissions or discrepancies shall be reported to the Designer.

DEMOLISHED WALLS CONSTRUCTION WALLS EXISTING WALLS

-

EXISTING WALLS, EXTERIOR GLAZING, MULLIONS, STRUCTURAL COLUMNS TO REMAIN INTACT

-

LEAVE EXISTING FLOORING AS IS.

-

REMOVE ALL EXISTING LIGHTING AND TRACKS (EXCEPT LIGHTS ATTACHED TO EXTERIOR WINDOW MULLIONS ON NORTH)REMOVE EXISTING MILLWORK.

-

REMOVE MATERIAL AND PRODUCTS TO BE DISPOSED OF, REUSED AND/OR SALVAGED AS DIRECTED BY OWNER

-

ACCESS TO SITE AND WORK SCHEDULE TO BE COORDINATED WITH [OWNER]

-

KEEP SITE CLEAN AND MAINTAIN SAFETY OF PUBLIC DURING DEMOLITION, CONSTRUCTION

-

REMOVE ALL INTERIOR WALLS AS SHOWN DOTTED

-

REMOVE EXISTING SINKS AND KITCHEN APPLIANCES. DISPOSE AS SPECIFIED BY OWNER.

REMOVE SINK AND ADJACENT COUNTER

ISSUE NO.

ISSUED FOR:

1.

PHASE ONE REVISION INITIALS XXXX

2.

PHASE TWO REVISION INITIALS XXXX

revision

description

BY:

by

DATE:

date

JH|DESIGNS 1090 W.GEORGIA ST. VANCOUVER, BC V6E 3V7 TEL. (604) 68 FAX. (604) 68

PROJECT:

MARKET RESEARCH GROUP 7785 WEST HASTINGS STREET VANCOUVER, BC

TITLE:

DEMOLTIION & CONSTRUCTION NOTES DATE:

AUGUST 6, 2015

SCALE:

1/4" = 1'-0"

DRAWN BY:

JENNIFER HEINRICH

DRAWING NO.

ID-002


COPYRIGHT RESERVED: This drawing and design are, and at all times remain, the exclusive property of Jennifer Heinrich, and can be reproduced only with written consent. This drawing must not be scaled. Contractors shall verify all dimensions prior to commencement of work, and any omissions or discrepancies shall be reported to the Designer.

C O N S T R U C T I O N L E G E ND

ADMINISTRATIVE ASSISTANTS OFFICE(RM 103) ACCOUNT EXCUTIVES(RM 104)

B

B

B

G

CONFERENCE ROOM(RM 102)

DEMOLISHED WALLS CONSTRUCTION WALLS

PIPE CHASE

EXISTING WALLS G

DW

F PIPE

4'-0"

VP OPERATIONS OFFICE (RM 105)

MW

PLAN DEMOLITION KEY NOTES:

LUNCH ROOM/ BEVERAGE CENTER (RM 115)

10"

CHASE

REF.

A

F

RECEPTION/ WAITING AREA (RM 101)

C

REMOVE EXISTING MILLWORK, SHELVING AND PLUMBING FIXTURES. PATCH AND MAKE GOOD EXISTING PARTITION.

4

REMOVE EXISTING VINYL FLOORING & RUBBER BASE. PREP CONCRETE SLAB FOR NEW FLOOR FINISH. REFER TO SPEC. COORDINATE WITH EXTENT OF NEW FLOORING FINISHES.

5

REMOVE EXISTING INTERIOR DOOR AND WINDOWS AND THEIR CORRESPONDING FRAMES. PATCH AND MAKE GOOD REMAINING PARTITION TO SUIT NEW PLAN AS REQUIRED.CUT EXISTING WALL AS REQUIRED TO SUIT NEW DOOR OPENING

ISSUE NO.

ISSUED FOR:

1.

PHASE ONE REVISION INITIALS XXXX

2.

PHASE TWO REVISION INITIALS XXXX

revision

description

CL

1'-0"

CHASE

1'-6"

CL

E

CL

C

LOCKABLE SUPPLY SHELF

·

· WASHROOM (RM 111)

PIPE

1'-6"

CL WASHROOM (RM 110)

PRESIDENT'S OFFICE (RM 106)

· · · · · ·

ALL WORKMANSHIP AND METHODS OF CONSTRUCTION TO MEET REQUIREMENTS OF THE CURRENT EDITION OF THE BRITISH COLUMBIA BUILDING CODE AND CITY OF VANCOUVER BYLAWS CONTRACTOR TO CONFIRM DIMENSIONS ON SITE PRIOR TO COMMENCING CONSTRUCTION. DISCREPANCIES TO BE REPORTED TO THE DESIGNER PRIOR TO PROCEEDING. WRITTEN DIMENSIONS TO TAKE PRECEDENCE OVER SCALED DIMENSIONS REMOVED MATERIAL AND PRODUCTS TO BE DISPOSED OF OR SALVAGED AS DIRECTED BY OWNER ACCESS TO SITE AND WORK SCHEDULE TO BE COORDINATED WITH DESIGNER KEEP SITE CLEAN AND MAINTAIN SAFETY OF PUBLIC DURING DEMOLITION, CONSTRUCTION. BLOCK AND BRACE AS REQUIRED ALL MATERIALS SHOULD ARRIVE ON SITE IN ORIGINAL PACKAGING CONTRACTOR MUST CHECK THE CONDITION OF MATERIALS UPON DELIVERY USE ONLY MOST REVISED DRAWINGS REPORT ALL ERRORS OR OMISSIONS TO THE DESIGNER, ARCHITECT OR ENGINEER

·

SITE MEASUREMENTS REQUIRED. ALL CONTRACTORS SHALL VERIFY ON-SITE CONDITIONS, DIMENSIONS, DRAWINGS, DETAILS AND SPECIFICATIONS AND REPORT ALL ERRORS AND OMISSIONS TO THE DESIGNER BEFORE PROCEEDING WITH WORK.

·

DO NOT SCALE THE DRAWINGS. THESE DRAWINGS REMAIN THE PROPERTY OF THE DESIGNER.

·

GENERAL CONTRACTOR TO VISIT SITE PRIOR TO PRICING AND CONSTRUCTION TO DETERMINE EXTENT OF EXISTING T-BAR CEILING AND ACOUSTIC TILE TO BE REMOVED AND/OR DEMOLISHED TO ACCOMMODATE NEW CONSTRUCTION.

CHASE

REFERENCE LIBRARY (RM 109)

PIPE

GROUP SURVEY ROOM A (RM 108)

·

ALL CEILING COMPONENTS AND MECHANICAL/ ELECTRICAL DEVICES TO BE INSTALLED TO SEISMIC REQUIREMENTS OF BC.

·

EXECUTIVE VP OFFICE (RM 107)

·

CEILING HEIGHTS AS NOTED ON ELEVATIONS

·

SEE PAGES ID-002 FOR DEMOLITION NOTES

ID-003 1

CONSTRUCTION PLAN SCALE: 1/4" = 1'-0"

by

date

JH|DESIGNS 1090 W.GEORGIA ST. VANCOUVER, BC V6E 3V7 TEL. (604) 270 - 4710

NOTE:

E

B

DATE:

REMOVE SINK AND ADJACENT COUNTER

PROJECT:

D

BY:

GENERAL NOTES ·

PIPE

1'-0"

WASHROOM (RM 112)

C

GENERAL STORAGE CLOSET

3

CL

CL

WORK ROOM (RM 114)

E

MAKE GOOD AND FINISH REMAINING WALL PROTECTION ADJACENT TO DEMOLITION WORK. FINISH TO MATCH EXISTING.

CHASE

B

D

2

B

1'-6"

D

PIPE CHASE

GROUP SURVEY ROOM B (RM 113)

REMOVE EXISTING GYPSUM BOARD PARTITION INCLUDING ALL PROTECTION, RAILS & ELEC./ MECH. DEVICES.

6

1'-0"

G

1

MARKET RESEARCH GROUP 7785 WEST HASTINGS STREET VANCOUVER, BC

TITLE:

CONSTRUCTION PLAN

DATE:

AUGUST 6, 2015

SCALE:

1/4" = 1'-0"

DRAWN BY:

JENNIFER HEINRICH

DRAWING NO.

ID-003


COPYRIGHT RESERVED: This drawing and design are, and at all times remain, the exclusive property of Jennifer Heinrich, and can be reproduced only with written consent. This drawing must not be scaled. Contractors shall verify all dimensions prior to commencement of work, and any omissions or discrepancies shall be reported to the Designer.

LIGHTING SPECIFICATION CODE

SYMBOL

PICTURE

MANUFACTURER MP LIGHTING

L-1 KUZCO LIGHTING

L-2 MP LIGHTING

L-3 KUZCO LIGHTING

L-4 KUZCO LIGHTING

L-5 KUZCO LIGHTING

L-6 ARTCRAFT LIGHTING

L-7

PRODUCT INFO.

QUANTITY

MP LIGHTING; L600 INTERIOR SURFACE MOUNT DOWNLIGHT; 3000K; CRI 97; FLOOD (40°); 120V; REFLECTOR COLOUR: SILVER SPECULAR; FINISH: MATTE ANODIZED; W4-5/8" X H4-3/8"

106

KUZCO LIGHTING; MOD. NO.: 489110 CHANDELIER; 120V; G9 LAMPING; L49-3/4" X W28-3/4 X H8-3/4"

4

MP LIGHTING; L73C1 INTERIOR CANOPY MOUNT LED SPOTLIGHT; 3000K; CRI 75-82; FLOOD (60°); CUSTOM 6" STEM; FINISH: MATTE CLEAR ANODIZED; W4-1/8" X L 3-3/8" X 6"H

6

KUZCO LIGHTING; MOD. NO.: 401042B PENDANT LAMP; 120V; GY6.35 BI-PIN LAMPING W2-3/4” X L2-3/4” X H6”

KUZCO LIGHTING; MOD. NO.: 4400010CH-LED CHANDELIER; 120V; 3000K; D32-1/8” X H16-3/8”; CHROME FINISH

KUZCO LIGHTING; MOD. NO.: PD4401-CH PENDANT LAMP; 120V; D3-3/4" X H11-3/4"; METAL FINISH

ARTCRAFT LIGHTING; MOD. NO.: AC600BK; 120V; W18" X H24";G9 50W LAMPING; CHROME FINISH

PURCHASE LOCATION

NOTES

DARREL LANGE: T: (604) 708-1184 EXT. 125 C: (604) 782 - 8631

LUTRON REMOTE

VANCOUVER LIGHING: 101-12595 Bridgeport Rd., Richmond, BC, V6V 1J4 T: (604)-270-4641 E:richmond@vancouverlighting.ca

MOUNTED 7'-0" AFF.

DARREL LANGE: T: (604) 708-1184 EXT. 125 C: (604) 782 - 8631

RETROFIT MOUNTING PLATE W2-3/8" X H1/4" CANOPY

MOUNTED 7'-0" AFF.

3

VANCOUVER LIGHING: 101-12595 Bridgeport Rd., Richmond, BC, V6V 1J4 T: (604)-270-4641 E:richmond@vancouverlighting.ca

MOUNTED 6'-6" AFF.

3

VANCOUVER LIGHING: 101-12595 Bridgeport Rd., Richmond, BC, V6V 1J4 T: (604)-270-4641 E:richmond@vancouverlighting.ca

MOUNTED 7'-0" AFF.

4

VANCOUVER LIGHING: 101-12595 Bridgeport Rd., Richmond, BC, V6V 1J4 T: (604)-270-4641 E:richmond@vancouverlighting.ca

MOUNTED 7'-0" AFF.

2

VANCOUVER LIGHING: 101-12595 Bridgeport Rd., Richmond, BC, V6V 1J4 T: (604)-270-4641 E:richmond@vancouverlighting.ca

ISSUE NO.

ISSUED FOR:

1.

PHASE ONE REVISION J.H

revision

description

by

date

MARKET RESEARCH GROUP 7785 WEST HASTINGS STREET VANCOUVER, BC

ALL WORKMANSHIP AND METHODS OF CONSTRUCTION TO MEET REQUIREMENTS OF THE CURRENT EDITION OF THE BRITISH COLUMBIA BUILDING CODE AND CITY OF VANCOUVER BYLAWS CONTRACTOR TO CONFIRM DIMENSIONS ON SITE PRIOR TO COMMENCING CONSTRUCTION. DISCREPANCIES TO BE REPORTED TO THE DESIGNER PRIOR TO PROCEEDING. WRITTEN DIMENSIONS TO TAKE PRECEDENCE OVER SCALED DIMENSIONS REMOVED MATERIAL AND PRODUCTS TO BE DISPOSED OF OR SALVAGED AS DIRECTED BY OWNER ACCESS TO SITE AND WORK SCHEDULE TO BE COORDINATED WITH DESIGNER KEEP SITE CLEAN AND MAINTAIN SAFETY OF PUBLIC DURING DEMOLITION, CONSTRUCTION. BLOCK AND BRACE AS REQUIRED ALL MATERIALS SHOULD ARRIVE ON SITE IN ORIGINAL PACKAGING CONTRACTOR MUST CHECK THE CONDITION OF MATERIALS UPON DELIVERY

NOTE: · SITE MEASUREMENTS REQUIRED. ALL CONTRACTORS SHALL VERIFY ON-SITE CONDITIONS, DIMENSIONS, DRAWINGS, DETAILS AND SPECIFICATIONS AND REPORT ALL ERRORS AND OMISSIONS TO THE DESIGNER BEFORE PROCEEDING WITH WORK. · DO NOT SCALE THE DRAWINGS. THESE DRAWINGS REMAIN THE PROPERTY OF THE DESIGNER. · GENERAL CONTRACTOR TO VISIT SITE PRIOR TO PRICING AND CONSTRUCTION TO DETERMINE EXTENT OF EXISTING T-BAR CEILING AND ACOUSTIC TILE TO BE REMOVED AND/OR DEMOLISHED TO ACCOMMODATE NEW CONSTRUCTION. · ALL CEILING COMPONENTS AND MECHANICAL/ ELECTRICAL DEVICES TO BE INSTALLED TO SEISMIC REQUIREMENTS OF BC. · CEILING HEIGHTS AS NOTED ON PLAN

JULY 30/15

1090 W.GEORGIA ST. VANCOUVER, BC V6E 3V7 TEL. (604) 270 - 4710

GENERAL NOTES · · · · · ·

DATE:

JH|DESIGNS

PROJECT:

·

BY:

TITLE:

LIGHTING SCHEDULE

ID-004 1

LIGHTING SCHEDULE SCALE: NTS

DATE:

AUGUST 6, 2015

SCALE:

NTS

DRAWN BY:

JENNIFER HEINRICH

DRAWING NO.

ID-004


COPYRIGHT RESERVED: This drawing and design are, and at all times remain, the exclusive property of Jennifer Heinrich, and can be reproduced only with written consent. This drawing must not be scaled. Contractors shall verify all dimensions prior to commencement of work, and any omissions or discrepancies shall be reported to the Designer.

DOOR ELEVATIONS DOOR SCHEDULE DOOR

DOOR TYPES

FRAME

DOOR OPENINGS WIDTH

HEIGHT

THICKNESSES

MATERIAL

MATERIAL

REMARKS FINISH

D101A

A

6'-0"

9'-0"

1 -3/4"

W'D

MT'L

SS

D101B

G

5'-0"

6'-0"

1 - 0"

WD

MT'L

SS

D102A

B

3'-0"

6'-0"

1 -3/4"

W'D/GL'S/MT'L

MT'L

SS

D102B

G

5'-0"

6'-0"

1 - 0"

WD

MT'L

SS

D103

B

3'-0"

6'-0"

1 -3/4"

W'D/GL'S/MT'L

MT'L

SS

D104

B

3'-0"

6'-0"

1 -3/4"

W'D/GL'S/MT'L

MT'L

SS

D105

D

3'-0"

6'-0"

1 -3/4"

W'D/GL'S/MT'L

MT'L

SS

D106

D

3'-0"

6'-0"

1 -3/4"

W'D/GL'S/MT'L

MT'L

SS

D107

D

3'-0"

6'-0"

1 -3/4"

W'D/GL'S/MT'L

MT'L

SS

D108

B

3'-0"

6'-0"

1 -3/4"

W'D/GL'S/MT'L

MT'L

SS

D109

E

4'-0"

6'-0"

1 -1/2"

WD

WD

PT

D110

C

3'-0"

6'-0"

1 -3/4"

W'D/MT'L

MT'L

SS

FROSTED GLASS PANEL

1 3/4" SOLID WOOD CORE

1 3/4" SOLID WOOD CORE

METAL FRAME IN SELECTED FINISH

STAINLESS STEEL FRAME

GROUND LINE

GROUND LINE

A

ENTRY DOORS SCALE:

7"X43" WOOD PANELS IN SELECTED FINISH

1/4" = 1'- 0"

PRESIDENT & VP DOORS SCALE:

1/4" = 1'- 0"

D

6"X60" GLASS WINDOW 1 3/4" SOLID WOOD CORE 1 3/4" SOLID WOOD CORE

D111

C

3'-0"

6'-0"

1 -3/4"

W'D/MT'L

MT'L

SS

D112

C

3'-0"

6'-0"

1 -3/4"

W'D/MT'L

MT'L

SS

D113

B

3'-0"

6'-0"

1 -3/4"

W'D/GL'S/MT'L

MT'L

SS

D114A

B

3'-0"

6'-0"

1 -3/4"

W'D/GL'S/MT'L

MT'L

SS

D114B

E

4'-0"

6'-0"

1 -1/2"

WD

WD

PT

D114C

E

4'-0"

6'-0"

1 -1/2"

WD

WD

PT

D114D

G

5'-0"

6'-0"

1 - 0"

WD

MT'L

SS

D115A

F

2'-10"

6'-0"

1 -3/4"

W'D/GL'S/MT'L

MT'L

SS

2-1/2" X 11-1/4" METAL PUSHPLATE IN SELECTED FINISH

D115B

F

2'-10"

6'-0"

1 -3/4"

W'D/GL'S/MT'L

MT'L

SS

1 3/4" SOLID WOOD CORE

STAINLESS STEEL FRAME

METAL FRAME IN SELECTED FINISH

ISSUE NO.

ISSUED FOR:

1.

PHASE ONE REVISION J.H

JULY 30/15

revision

description

date

GROUND LINE

OFFICE DOOR SCALE:

1/4" = 1'- 0"

E

TYP. WOOD DOOR

B

SCALE:

1/4" = 1'- 0"

BATHROOM DOOR SCALE:

1/4" = 1'- 0"

1090 W.GEORGIA ST. VANCOUVER, BC V6E 3V7 TEL. (604) 270 - 4710

C PROJECT:

GENERAL NOTES · · · · · ·

ALL WORKMANSHIP AND METHODS OF CONSTRUCTION TO MEET REQUIREMENTS OF THE CURRENT EDITION OF THE BRITISH COLUMBIA BUILDING CODE AND CITY OF VANCOUVER BYLAWS CONTRACTOR TO CONFIRM DIMENSIONS ON SITE PRIOR TO COMMENCING CONSTRUCTION. DISCREPANCIES TO BE REPORTED TO THE DESIGNER PRIOR TO PROCEEDING. WRITTEN DIMENSIONS TO TAKE PRECEDENCE OVER SCALED DIMENSIONS REMOVED MATERIAL AND PRODUCTS TO BE DISPOSED OF OR SALVAGED AS DIRECTED BY OWNER ACCESS TO SITE AND WORK SCHEDULE TO BE COORDINATED WITH DESIGNER KEEP SITE CLEAN AND MAINTAIN SAFETY OF PUBLIC DURING DEMOLITION, CONSTRUCTION. BLOCK AND BRACE AS REQUIRED ALL MATERIALS SHOULD ARRIVE ON SITE IN ORIGINAL PACKAGING CONTRACTOR MUST CHECK THE CONDITION OF MATERIALS UPON DELIVERY

NOTE: · SITE MEASUREMENTS REQUIRED. ALL CONTRACTORS SHALL VERIFY ON-SITE CONDITIONS, DIMENSIONS, DRAWINGS, DETAILS AND SPECIFICATIONS AND REPORT ALL ERRORS AND OMISSIONS TO THE DESIGNER BEFORE PROCEEDING WITH WORK. · DO NOT SCALE THE DRAWINGS. THESE DRAWINGS REMAIN THE PROPERTY OF THE DESIGNER. · GENERAL CONTRACTOR TO VISIT SITE PRIOR TO PRICING AND CONSTRUCTION TO DETERMINE EXTENT OF EXISTING T-BAR CEILING AND ACOUSTIC TILE TO BE REMOVED AND/OR DEMOLISHED TO ACCOMMODATE NEW CONSTRUCTION. · ALL CEILING COMPONENTS AND MECHANICAL/ ELECTRICAL DEVICES TO BE INSTALLED TO SEISMIC REQUIREMENTS OF BC. · CEILING HEIGHTS AS NOTED ON PLAN

by

JH|DESIGNS

GROUND LINE

·

DATE:

GROUND LINE

METAL FRAME IN SELECTED FINISH 8" X 36" METAL KICKPLATE IN SELECTED FINISH

eck room

BY:

1 1/2" SOLID WOOD CORE

MARKET RESEARCH GROUP 7785 WEST HASTINGS STREET VANCOUVER, BC

WOODEN FRAME IN SELECTED PAINT FINISH GROUND LINE TITLE:

BI-FOLD CLOSET DOOR SCALE:

ID-005 1

1/4" = 1'- 0"

G

DOOR SCHEDULE

DOOR SCHEDULE SCALE: NTS

DATE:

AUGUST 6, 2015

SCALE:

NTS

DRAWN BY:

JENNIFER HEINRICH

DRAWING NO.

ID-005


COPYRIGHT RESERVED: This drawing and design are, and at all times remain, the exclusive property of Jennifer Heinrich, and can be reproduced only with written consent. This drawing must not be scaled. Contractors shall verify all dimensions prior to commencement of work, and any omissions or discrepancies shall be reported to the Designer.

ADMINISTRATIVE ASSISTANTS OFFICE(RM 103) ACCOUNT EXCUTIVES(RM 104)

SDLV

LIGHTING LEGEND CONFERENCE ROOM(RM 102)

SDSS SDLV

SDLV S S

PIPE CHASE W1 EX

W1 EX

W1 EX

2'X2' ACOUSTICAL SUSPENDED CEILING ASSEMBLY

B

ID-010

SDLV S

D

S3

A

ID-010

ID-010

A

ID-010

PIPE

LUNCH ROOM/ BEVERAGE CENTER (RM 115)

VP OPERATIONS OFFICE (RM 105)

C

C

ID-010

ID-010

CHASE

EX W2

S

D

ID-010

EX W2

B

ID-010

DIMMER SWITCH DIMMER SWITCH, LOW VOLTAGE OCCUPANCY SENSOR/ SWITCH COMBINATION DAYLIGHT SENSOR/ SWITCH COMBINATION

OSS

WORK ROOM (RM 114)

EX

CHASE

S

CHASE

OSS

S EX

W2

C2

WASHROOM (RM 110)

CHROME PENDANT LAMP ACCENT CHANDELIER

W1 EX

REFERENCE LIBRARY (RM 109)

CEI LING LEGEND

GROUP SURVEY ROOM A (RM 108)

1. 2. 3.

PIPE

W2

EXECUTIVE VP OFFICE (RM 107)

GENERAL NOTES · · · · · · ·

ALL WORKMANSHIP AND METHODS OF CONSTRUCTION TO MEET REQUIREMENTS OF THE CURRENT EDITION OF THE BRITISH COLUMBIA BUILDING CODE AND CITY OF VANCOUVER BYLAWS CONTRACTOR TO CONFIRM DIMENSIONS ON SITE PRIOR TO COMMENCING CONSTRUCTION. DISCREPANCIES TO BE REPORTED TO THE DESIGNER PRIOR TO PROCEEDING. WRITTEN DIMENSIONS TO TAKE PRECEDENCE OVER SCALED DIMENSIONS REMOVED MATERIAL AND PRODUCTS TO BE DISPOSED OF OR SALVAGED AS DIRECTED BY OWNER ACCESS TO SITE AND WORK SCHEDULE TO BE COORDINATED WITH DESIGNER KEEP SITE CLEAN AND MAINTAIN SAFETY OF PUBLIC DURING DEMOLITION, CONSTRUCTION. BLOCK AND BRACE AS REQUIRED ALL MATERIALS SHOULD ARRIVE ON SITE IN ORIGINAL PACKAGING CONTRACTOR MUST CHECK THE CONDITION OF MATERIALS UPON DELIVERY

NOTE: · SITE MEASUREMENTS REQUIRED. ALL CONTRACTORS SHALL VERIFY ON-SITE CONDITIONS, DIMENSIONS, DRAWINGS, DETAILS AND SPECIFICATIONS AND REPORT ALL ERRORS AND OMISSIONS TO THE DESIGNER BEFORE PROCEEDING WITH WORK. · DO NOT SCALE THE DRAWINGS. THESE DRAWINGS REMAIN THE PROPERTY OF THE DESIGNER. · GENERAL CONTRACTOR TO VISIT SITE PRIOR TO PRICING AND CONSTRUCTION TO DETERMINE EXTENT OF EXISTING T-BAR CEILING AND ACOUSTIC TILE TO BE REMOVED AND/OR DEMOLISHED TO ACCOMMODATE NEW CONSTRUCTION. · ALL CEILING COMPONENTS AND MECHANICAL/ ELECTRICAL DEVICES TO BE INSTALLED TO SEISMIC REQUIREMENTS OF BC. · CEILING HEIGHTS AS NOTED ON PLAN

description

by

date

JH|DESIGNS 1090 W.GEORGIA ST. VANCOUVER, BC V6E 3V7 TEL. (604) 270 - 4710

CHASE

S

EX

SDLV S

revision

LARGE LED CHANDELIER

PIPE

W3

EX

PHASE TWO REVISION INITIALS XXXX

BLUE PENDANT LAMP

LOCKABLE SUPPLY SHELF

W2

2.

SMALL CHANDELIER

SDLV S WASHROOM (RM 111)

C2

EX

PHASE ONE REVISION INITIALS XXXX

DATE:

CANOPY MOUNTED LED SPOT LIGHT

W3

SDLV S

1.

BY:

DOWN LIGHT

WASHROOM (RM 112)

C2

PRESIDENT'S OFFICE (RM 106)

ISSUED FOR:

W3 EX

EX

GENERAL STORAGE CLOSET

ISSUE NO.

PIPE

W1

OSS

W2

THREE-WAY SWITCH

SDSS

SD S

EX

S3 SD SDLV

S

SS

OSS

PIPE CHASE

GROUP SURVEY ROOM B (RM 113)

SINGLE POLE SWITCH

SOSS

RECEPTION/ WAITING AREA (RM 101)

W2

S3

EX

S

PROJECT:

ALL CEILINGS SHALL BE TYPE 'C1' AT 8'-6" AFF UNLESS OTHERWISE OTED. REFER TO COMPLETE SET OF DOCUMENTS (DIV. 15 & 16) FOR CEILING WORK OUTSIDE OF RENOVATION AREA. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR ALL CEILING DEVICES.

EX

EXISTING SUSPENDED T-BAR CEILING - REFER TO ALL CONTRACT DOCUMENTS FOR COMPLETE SCOPE OF WORK AFFECTING EXISTING CEILINGS

C1

24" X 47-1/'4" FACE SCORED ACOUSTIC CEILING TILE WI/ SUSPENDED T-BAR SYSTEM

W1

3/8" SUSPENDED STEEL STUD FRAMING AS REQUIRED

W2

ALUMINUM COMPOSITE PANEL; GALVANIZED 'Z' BARS; 1-1/2" RIGID INSULTATION' AIR/VAPOUR RETARDER; 3/8" GYPSUM SHEATHING; STEEL STUD FRAMING AS REQUIRED

W3

3/8" THICK WATER RESISTANT GYPSUM BOARD W/ EPOXY PAINT SUSPENDED STEEL STUD FRAMING AS REQUIRED

7785 WEST HASTINGS STREET VANCOUVER, BC

TITLE:

REFELECTED CEILING PLAN

LIGHTING NOTES -

ALL MATERIALS SHOULD ARRIVE ON SITE IN ORIGINAL PACKAGING CONTRACTOR MUST CHECK THE CONDITION OF MATERIALS UPON DELIVERY CONTRACTOR TO CONSULT WITH DESIGNER PRIOR TO MAKING ANY CHANGES TO THE LIGHTING FIXTURE LAYOUT SUBSTITUTE LIGHTING WILL NOT BE ACCEPTED UNLESS APPROVED BY DESIGNER GANG TOGETHER SWITCHES AND OUTLETS WHERE POSSIBLE ALL SWITCTHES TO BE MOUNTED AT 48" AFF UNLESS OTHERWISE NOTED ALL COVER PLATES TO BE DECORA (WHITE) MOUNTED VERTICALLY UNLESS NOTED OTHERWISE ALL SAFETY DEVICES (SPRINKLER/ SMOKE ALARMS) ARE SHOW FOR DESIGN INTENT ONLY. REFER TO MECHANICAL AND ELECTRICAL ENGINEERS' DRAWINGS FOR EXACT LOCATIONS. LOCATIONS TO COMPLY WITH ALL CODES AND BYLAWS.

ID-006 1

LIGHTING PLAN SCALE: 1/4" = 1'-0"

MARKET RESEARCH GROUP

DATE:

AUGUST 6, 2015

SCALE:

1/4" = 1'-0"

DRAWN BY:

JENNIFER HEINRICH

DRAWING NO.

ID-006


COPYRIGHT RESERVED: This drawing and design are, and at all times remain, the exclusive property of Jennifer Heinrich, and can be reproduced only with written consent. This drawing must not be scaled. Contractors shall verify all dimensions prior to commencement of work, and any omissions or discrepancies shall be reported to the Designer.

C1

C1

C1

BB1

BB1

BB1

CM1

CM1

CM1

ADMINISTRATIVE ASSISTANTS OFFICE(RM 103) ACCOUNT EXCUTIVES(RM 104)

B

B

CONFERENCE ROOM(RM 102)

B

G

C1 BB1 CM1

PIPE CHASE P2 C1

BB1 G

B

CM1

ID-010

D

A

DW

ID-010

MW

ID-010

A

F

FINISHES

P2

ID-010

PIPE

LUNCH ROOM/ BEVERAGE CENTER (RM 115)

P1

VP OPERATIONS OFFICE (RM 105)

T1

C

C

ID-010

ID-010

C1

P2

MANUFACTURER: BENJAMIN MOORE MODEL NO.: 2122-40 COLOUR: "SMOKE"

CM1

C2

T2

REF.

D

CM1

ID-010

F

RECEPTION/ WAITING AREA (RM 101)

P1

GROUP SURVEY ROOM B (RM 113)

C1

BB1 G

CM1

D

WC3

PIPE CHASE

B

B

C

T2 CM1

WORK ROOM (RM 114)

T3

WASHROOM (RM 112)

PIPE

D

C1 BB1

C1

CM1

C

BB1 CM1

T2 CM1

T3

C1

E

BB1

CM1

GENERAL STORAGE CLOSET

C2 BB1

C1 BB1

CM1 P2

CHASE

WASHROOM (RM 111)

E

C

LOCKABLE SUPPLY SHELF

MANUFACTURER: BENJAMIN MOORE MODEL NO.: 2123-70 COLOUR: "ICE MIST"

P3

A

CHASE

B

ID-010

WC1

BB1

T2 CM1

T3

WASHROOM (RM 110)

WC1

MANUFACTURER: ODYSSEY WALLCOVERINGS MODEL NO.: LENTEX INDULGENCE GAZEBO COLOUR: "MIMOSA" NO. 6137-GZ

WC2

MANUFACTURER: ODYSSEY WALLCOVERINGS MODEL NO.: METALLIC CRACKLE COLOUR: "MOON DUST" NO. ODY - 1638

WC3

MANUFACTURER: ODYSSEY WALLCOVERINGS MODEL NO.: METALLIC CRACKLE COLOUR: "MUTED AGUA" NO. ODY-1639

C1

MANUFACTURER: INTERFACE MODEL NO.: WHOLE EARTH COLLECTION - WE154 COLOUR: 104463 " STORM"

C2

MANUFACTURER: INTERFACE MODEL NO.: RECLAIM COLOUR: 104142 "WEATHERED BLUE"

T1

MANUFACTURER: OLYMPIA TILE MODEL NO.: TIMBER SERIES PORCELAIN WOOD LOOK TILE COLOUR: TR.TM.GRY 0624 "GREY MATTE"

T2

MANUFACTURER: FONTILE MODEL NO.: CUBICA DIAMOND CERAMIC WALL TILE COLOUR: BLANCO

PIPE

BB1 CM1

WC2

P1

MANUFACTURER: BENJAMIN MOORE MODEL NO.: OC-130 COLOUR: "CLOUD WHITE"

CHASE

BB1

LEGEND

MANUFACTURER: FONTILE MODEL NO.: MANHATTAN CERAMIC TILE COLOUR: GRIS

T3

T2

E

C1 BB1 CM1

D

BB1

CM1 REFERENCE LIBRARY (RM 109)

B

P2

BB1

CHASE

PRESIDENT'S OFFICE (RM 106)

GROUP SURVEY ROOM A (RM 108)

CM1

DISTRIBUTOR: HOME DEPOT MODEL NO.: ALEXANDRIA BASEBOARD - 07622 - F60922 COLOUR: WHITE

ISSUE NO.

ISSUED FOR:

1.

PHASE ONE REVISION INITIALS XXXX

2.

PHASE TWO REVISION INITIALS XXXX

revision

description

C1 CM1

CM1

EXECUTIVE VP OFFICE (RM 107)

PIPE

BB1

DISTRIBUTOR: ALEXANDRIA MOULDING MODEL NO.: ALEXANDRIA CROWN MOULDING 05981-96168C COLOUR: WHITE

1.

ALL WALLS TO BE PAINED P1: NO. OC-130 "CLOUD WHITE" BY BENJAMIN MOORE, UNLESS OTHERWISE NOTED

2.

ALL BASEBOARDS ARE "ALEXANDRIA BASEBOARD " NO. 07622-F6096C PAINTED P3: NO. 2123-70 "ICE MIST" BY BENJAMIN MOORE, UNLESS OTHERWISE NOTED

3.

ALL CROWN MOULDINGS ARE "ALEXANDRIA CROWN MOULDING " NO. 90983-96192C PAINTED P3: NO. 2123-70 "ICE MIST" BY BENJAMIN MOORE, UNLESS

4.

ALL CEILINGS ARE TO BE PAINTED P3: NO. 2123-70 "ICE MIST" BY BENJAMIN MOORE

· · · · · · · ·

ALL WORKMANSHIP AND METHODS OF CONSTRUCTION TO MEET REQUIREMENTS OF THE CURRENT EDITION OF THE BRITISH COLUMBIA BUILDING CODE AND CITY OF VANCOUVER BYLAWS CONTRACTOR TO CONFIRM DIMENSIONS ON SITE PRIOR TO COMMENCING CONSTRUCTION. DISCREPANCIES TO BE REPORTED TO THE DESIGNER PRIOR TO PROCEEDING. WRITTEN DIMENSIONS TO TAKE PRECEDENCE OVER SCALED DIMENSIONS REMOVED MATERIAL AND PRODUCTS TO BE DISPOSED OF OR SALVAGED AS DIRECTED BY OWNER ACCESS TO SITE AND WORK SCHEDULE TO BE COORDINATED WITH DESIGNER KEEP SITE CLEAN AND MAINTAIN SAFETY OF PUBLIC DURING DEMOLITION, CONSTRUCTION. BLOCK AND BRACE AS REQUIRED ALL MATERIALS SHOULD ARRIVE ON SITE IN ORIGINAL PACKAGING CONTRACTOR MUST CHECK THE CONDITION OF MATERIALS UPON DELIVERY USE ONLY MOST REVISED DRAWINGS REPORT ALL ERRORS OR OMISSIONS TO THE DESIGNER, ARCHITECT OR ENGINEER

NOTE: · SITE MEASUREMENTS REQUIRED. ALL CONTRACTORS SHALL VERIFY ON-SITE CONDITIONS, DIMENSIONS, DRAWINGS, DETAILS AND SPECIFICATIONS AND REPORT ALL ERRORS AND OMISSIONS TO THE DESIGNER BEFORE PROCEEDING WITH WORK. · DO NOT SCALE THE DRAWINGS. THESE DRAWINGS REMAIN THE PROPERTY OF THE DESIGNER. · GENERAL CONTRACTOR TO VISIT SITE PRIOR TO PRICING AND CONSTRUCTION TO DETERMINE EXTENT OF EXISTING T-BAR CEILING AND ACOUSTIC TILE TO BE REMOVED AND/OR DEMOLISHED TO ACCOMMODATE NEW CONSTRUCTION. · ALL CEILING COMPONENTS AND MECHANICAL/ ELECTRICAL DEVICES TO BE INSTALLED TO SEISMIC REQUIREMENTS OF BC. · CEILING HEIGHTS AS NOTED ON PLAN

MARKET RESEARCH GROUP 7785 WEST HASTINGS STREET VANCOUVER, BC

OTHERWISE NOTED

TITLE:

FINISHES SCHEDULE

GENERAL NOTES ·

date

1090 W.GEORGIA ST. VANCOUVER, BC V6E 3V7 TEL. (604) 270 - 4710

FINISHES NOTES

C1

BB1

by

DATE:

JH|DESIGNS

PROJECT:

WC3

BY:

ID-007 1

FINISHES SCHEDULE SCALE: 1/4" = 1'-0"

DATE:

AUGUST 6, 2015

SCALE:

1/4" = 1'-0"

DRAWN BY:

JENNIFER HEINRICH

DRAWING NO.

ID-007


COPYRIGHT RESERVED: This drawing and design are, and at all times remain, the exclusive property of Jennifer Heinrich, and can be reproduced only with written consent. This drawing must not be scaled. Contractors shall verify all dimensions prior to commencement of work, and any omissions or discrepancies shall be reported to the Designer.

S3 S1 C3

C4

C2

C2

C3

C3 C2

5 C

S3

C2 S2

T2

C2

C5

W1 S2

C5

S2

C2

W1

W3

S2

C5

S1

5 C

W3

W1

S2

C5

C4

5 C

S1

C3

ADMINISTRATIVE ASSISTANTS OFFICE(RM 103)

W1

5 C

S2

C3

S1

ACCOUNT EXCUTIVES(RM 104)

C2

C4

C2

C3

C2

C4

C2

S1

S1

FURNITURE LEGEND

CONFERENCE ROOM(RM 102)

PIPE CHASE

C1

SAYL CHAIR WITH SUSPENSION BACK

C3

EMBODY CHAIR

C2

EAMES ALUMINUM GROUP CHAIR

C4

LANDMARK CHAIR

C2

B

ID-010

W2

T4

C4

A

DW

ID-010

C4

A

MW

D

ID-010

EAMES WIRE CHAIR WITH LEATHER PADS

C5

ID-010

PIPE

C4

LUNCH ROOM/ BEVERAGE CENTER (RM 115)

VP OPERATIONS OFFICE (RM 105)

C

C5

T3 C5

C5 T3 S3

B

C5

ID-010

AGL TABLE GROUP

T1

C5

REF.

CH1

ID-010

CHASE

C5

C5

C

ID-010

C5

D

ID-010

3

C

C5

RECEPTION/ WAITING AREA (RM 101)

C5

EAMES ROUND TABLE - 84" D.

T2

T6

CH1

C4 C4

T5

WASHROOM (RM 111)

C

4

C 4

C4

C4 GENERAL STORAGE CLOSET

CH1

EAMES ROUND TABLE - 42" D.

T3

WASHROOM (RM 110)

PRESIDENT'S OFFICE (RM 106)

S4

OFFICINA TABLE

T5

NOGUCHI COFFEE TABLE

C2 C1

C1

C1

C1

C2

CH1

CHASE

W1

C1

description

S3

C4

EXECUTIVE VP OFFICE (RM 107)

C1

C1

C1

C1

C1

by

date

JH|DESIGNS

PROJECT:

C4

T1 T6

revision

METAFORM PORTFOLIO WORKSTATION

W2

CANVAS OFFICE LANDSCAPE WORKSTATION

PIPE

C4

C1

W2 CH1

CANVAS OFFICE LANDSCAPE DOCK BASED WORKSTATION

GROUP SURVEY ROOM A (RM 108)

C4

C4

PHASE TWO REVISION INITIALS XXXX

1090 W.GEORGIA ST. VANCOUVER, BC V6E 3V7 TEL. (604) 270 - 4710

REFERENCE LIBRARY (RM 109)

W2

2.

T4

T6

C4

PHASE ONE REVISION INITIALS XXXX

DATE:

POLYGON WIRE TABLE WITH ROUNDED HEXAGONAL SURFACE

LOCKABLE SUPPLY SHELF

S3

S3

1.

BY:

C4

T2

ISSUED FOR:

EAMES WIRE BASED ELLIPTICAL TABLE

T5

PIPE

C5

WASHROOM (RM 112)

PIPE

COPY MACHINE

CH1

T5

C4

WORK ROOM (RM 114)

C4

C4

MAIL SORTER

C5

CHASE

PIPE CHASE

CHASE

GROUP SURVEY ROOM B (RM 113)

ISSUE NO.

C1

S1

MARKET RESEARCH GROUP 7785 WEST HASTINGS STREET VANCOUVER, BC

TU STORAGE L-SERIES MOBILE PEDESTAL - FILE/FILE TITLE:

S2

GENERAL NOTES

FURNITURE NOTES -

· · · · · · ·

ALL WORKMANSHIP AND METHODS OF CONSTRUCTION TO MEET REQUIREMENTS OF THE CURRENT EDITION OF THE BRITISH COLUMBIA BUILDING CODE AND CITY OF VANCOUVER BYLAWS CONTRACTOR TO CONFIRM DIMENSIONS ON SITE PRIOR TO COMMENCING CONSTRUCTION. DISCREPANCIES TO BE REPORTED TO THE DESIGNER PRIOR TO PROCEEDING. WRITTEN DIMENSIONS TO TAKE PRECEDENCE OVER SCALED DIMENSIONS REMOVED MATERIAL AND PRODUCTS TO BE DISPOSED OF OR SALVAGED AS DIRECTED BY OWNER ACCESS TO SITE AND WORK SCHEDULE TO BE COORDINATED WITH DESIGNER KEEP SITE CLEAN AND MAINTAIN SAFETY OF PUBLIC DURING DEMOLITION, CONSTRUCTION. BLOCK AND BRACE AS REQUIRED ALL MATERIALS SHOULD ARRIVE ON SITE IN ORIGINAL PACKAGING CONTRACTOR MUST CHECK THE CONDITION OF MATERIALS UPON DELIVERY

NOTE: · SITE MEASUREMENTS REQUIRED. ALL CONTRACTORS SHALL VERIFY ON-SITE CONDITIONS, DIMENSIONS, DRAWINGS, DETAILS AND SPECIFICATIONS AND REPORT ALL ERRORS AND OMISSIONS TO THE DESIGNER BEFORE PROCEEDING WITH WORK. · DO NOT SCALE THE DRAWINGS. THESE DRAWINGS REMAIN THE PROPERTY OF THE DESIGNER. · GENERAL CONTRACTOR TO VISIT SITE PRIOR TO PRICING AND CONSTRUCTION TO DETERMINE EXTENT OF EXISTING T-BAR CEILING AND ACOUSTIC TILE TO BE REMOVED AND/OR DEMOLISHED TO ACCOMMODATE NEW CONSTRUCTION. · ALL CEILING COMPONENTS AND MECHANICAL/ ELECTRICAL DEVICES TO BE INSTALLED TO SEISMIC REQUIREMENTS OF BC. · CEILING HEIGHTS AS NOTED ON PLAN

-

ALL MATERIALS SHOULD ARRIVE ON SITE IN ORIGINAL PACKAGING CONTRACTOR MUST CHECK THE CONDITION OF MATERIALS UPON DELIVERY SUBMIT SAMPLES OF FURNITURE MATERIAL FOR APPROVAL

TU STORAGE MOBILE PEDESTAL BOX/BOX/FILE

FURNITURE PLAN

W3 S3

CH1

H-FRAME CREDENZA

TUXEDO CLASSIC COUCH

ID-008 1

FURNITURE PLAN SCALE: 1/4" = 1'-0"

CUSTOM RECEPTION DESK DATE:

AUGUST 6, 2015

SCALE:

1/4" = 1'-0"

DRAWN BY:

JENNIFER HEINRICH

DRAWING NO.

ID-008


COPYRIGHT RESERVED: This drawing and design are, and at all times remain, the exclusive property of Jennifer Heinrich, and can be reproduced only with written consent. This drawing must not be scaled. Contractors shall verify all dimensions prior to commencement of work, and any omissions or discrepancies shall be reported to the Designer.

FURNITURE SPECIFICATION SEATING CODE

PICTURE

MANUFACTURER HERMAN-MILLER

C1

C1

HERMAN-MILLER

C2

C2

HERMAN-MILLER

C3

C3

HERMAN-MILLER

C4

C4

HERMAN-MILLER

C5

C5

PRODUCT INFO.

TYPE: WORK CHAIR MODEL: SAYL CHAIR WITH SUSPENSION BACK SEAT FINISH: MAHARAM "HALLINGDAL" IN CUSTOM COLOURS BACK FINISH: NO. 63 "FOG" BACK SUPPORT: POSTUREFIT SCARAL SUPPORT TILT: LIMITER WITH ANGLE ARMPAD FINISH: NO. 63 " FOG" ARM TYPE: FULLY ADJUSTABLE 4D ARMS Y-TOWER/BASE FINISH: NO. 65 "STUDIO WHITE"/ "FOG" CASTERS: TRANSLUCENT HARD FLOOR OR CARPET SIZE: 34.25-38.35" H. X 24.5" W. X 24.5" D. TYPE: EXECUTIVE CHAIR MODEL: EAMES ALUMINUM GROUP CHAIR SEAT FINISH: MCL LEATHER IN RED NO. 1R05 BACK FINISH: MCL LEATHER IN RED NO. 1R05 BACK SUPPORT: POSTUREFIT SCARAL SUPPORT TILT: TILT LOCK WITH PNEUMATIC SEAT-HEIGHT ADJUSTMENT ARM TYPE: FIXED BASE & FRAME FINISH: POLISHED ALUMINUM "L" CASTERS: TRANSLUCENT HARD FLOOR OR CARPET SIZE: 29.75-44.875" H. X 23" W. X 17-18" D.

QUANTITY

16

PURCHASE LOCATION REPRESENTATIVE: KRYSTLE SCHOFIELD PHONE: (604) 629 - 6996

NOTES

HIGH BACK CHAIR LOCATION: GROUP SURVEY ROOM A AND ADMINISTRATIVE OFFICE

WORKSTATIONS CODE

PICTURE

MANUFACTURER HERMAN-MILLER

E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

W1

13

REPRESENTATIVE: KRYSTLE SCHOFIELD PHONE: (604) 629 - 6996

HIGH BACK CHAIR LOCATION: CONFERENCE AND PRESIDENT/ VICE PRESIDENT OFFICES

E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

HERMAN-MILLER TYPE: WORK CHAIR MODEL: EMBODY CHAIR SEAT & BACK FINISH: "BALANCE - GREEN APPLE" IN NO. 3506 BACK SUPPORT: STANDARD TILT: TILT LIMITER ARM FINISH: "BLACK" ARM TYPE: FULLY ADJUSTABLE FRAME FINISH: NO. 92 "WHITE" BASE FINISH: "CD POLISHED ALUMINUM" CASTERS: TRANSLUCENT HARD FLOOR OR CARPET SIZE: 42-45" H. X 29.5" W. X 15-18" D. TYPE: GUEST CHAIR MODEL: LANDMARK CHAIR SEAT & BACK FINISH: MAHARAM "MILLERSTRIPE" IN CUSTOM COLOURS ARM TYPE: FIXED BASE & FRAME FINISH:NO.6A2 "PLATINUM ASH" SIZE: 30.5 H. X 23" W. X 23" D.

TYPE: MULTI-USE GUEST CHAIR MODEL: EAMES WIRE CHAIR WITH LEATHER PADS SEAT & BACK FINISH: LEATHER IN NO. 2105 "CANYON" ARM TYPE: FIXED SEAT & BASE & BACK FINISH: "CH - CHROME" SIZE: 32.75 H. X 19" W. X 21.25" D.

3

REPRESENTATIVE: KRYSTLE SCHOFIELD

WORK CHAIR LOCATION: RECEPTION AND ACCOUNT EXECUTIVE OFFICE

W2

PHONE: (604) 629 - 6996 E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

23

REPRESENTATIVE: KRYSTLE SCHOFIELD PHONE: (604) 629 - 6996

LOW GUEST LOCATION: RECEPTION WAITING AREA, SURVEY ROOM B, PRESIDENT AND VP OFFICES, ACCOUNT EXECUTIVES

E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

20

REPRESENTATIVE: KRYSTLE SCHOFIELD PHONE: (604) 629 - 6996

HERMAN-MILLER

W3

LOW GUEST LOCATION: WORKROOM, AND LUNCH/BREAK ROOM, ADMINISTRATIVE ASSISTANT'S OFFICE

PRODUCT INFO.

QUANTITY

TYPE: WORKSTATION MODEL: CANVAS OFFICE LANDSCAPE DOCK BASED SURFACE FINISHES: "LGB -OAK ON ASH" WOODGRAIN LAMINATE SURFACE SIZE: 72" L. X 46" W. PENINSULA SURFACE LEG SUPPORT: SQUARE OPEN LEG FINISH: "MS - METALLIC SILVER" LEG SIZE: 36" H. MODESTY PANEL SIZE: 72" L. X 27" W. STORAGE: STORAGE FINISHES: "AGED CHERRY" DOCK STRUCTURE: 72" L. X 22" H. WITH STRUCTURAL FOOT DOCK FINISH: "LBG - SARUM TWILL" OVERHEAD STORAGE CABINET: 36" L. X 15" H. X 13.75" D. OVERHEAD HINGED DOOR CABINET: 36" L. X 15" H. X 13.75" D. LATERAL FILE: 36" W. X 20" D. ACCESSORIES: POWERED STORAGE, BEAM POWER. DATA CHANNEL, ORGANIZER,

4 WORK STATIONS 4 DOCKS 4 HINGED CABINETS 4 OVERHEAD CABINETS 4 OF EACH ACCESSORY 4 MODESTY PANELS 8 LATERAL FILES

TYPE: WORKSTATION MODEL: METAFORM PORTFOLIO SURFACE FINISHES: "NO. 98 "STUDIO WHITE" SURFACE SIZE: 72" L. X 36" W. X 29" H. LARGE RECTANGLE WORK SURFACE BASE: "G1 - GRAPHITE" STORAGE: STRAIGHT BLOCK: 36" W. X 14" D. X 42" H. CURVED BLOCK: 40.75" W. X 16.25" D. X 42" H. ACCESSORIES: STRAIGHT MEDIA RIG: 34.5" W X 13.25" D. X 54.75" H. CENTIPEDE SHELVING IN 12" W. X 10" D. X 2.75" H. IN NO. HY1 "HYPER ORANGE" SPARROW AND BOLT IT IN "MY1 - MINERAL GREY" TACK BOARD: 24" W. 0.25" D. X 28" H. IN "BK - BLACK" FINISH MARKER BOARD: 24" W. 0.5" D. X 28" H. IN NO. 98 "STUDIO WHITE" VENTRIPEDE UNITS: 23.75" H. X 4.5" W. X 2.75" D.

3 WORK STATIONS 12 CURVED BLOCKS 6 STRAIGHT BLOCKS 36 CENTIPEDE SHELF UNITS 3 MEDIA RIG 3 MARKER BOARD 3 TACK BOARD 12 SPARROW & BOLT IT 9 VENTRIPEDE UNITS (PRESIDENT'S OFFICE ONLY)

TYPE: WORKSTATION MODEL: CANVAS OFFICE LANDSCAPE SURFACE FINISHES: "NO. 98 "STUDIO WHITE" SURFACE SIZE: 60" L. X 24" W. X 29" H. - 120 DEGREE SURFACE LEG SUPPORT: SQUARE OPEN LEG FINISH: "MS - METALLIC SILVER" LEG SIZE: 36" H. STORAGE: LOW CREDENZA: 72" W. X 20" D. CREDENZA FINISH: "AGED CHERRY" ACCESSORIES: POWERED STORAGE, BEAM POWER. DATA CHANNEL, ORGANIZER, MODESTY PANEL: 60"

2 WORK STATION 2 OF EACH ACCESSORY 2 MODESTY PANEL 2 LOW CREDENZA

PURCHASE LOCATION REPRESENTATIVE: KRYSTLE SCHOFIELD PHONE: (604) 629 - 6996

NOTES

WORKSTATION LOCATION: ADMINISTRATIVE ASSISTANTS' OFFICE

E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

REPRESENTATIVE: KRYSTLE SCHOFIELD PHONE: (604) 629 - 6996

WORKSTATION LOCATION: PRESIDENT & VP OFFICES

E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

REPRESENTATIVE: KRYSTLE SCHOFIELD PHONE: (604) 629 - 6996

WORKSTATION LOCATION: ACCOUNT EXECUTIVE OFFICES; CREDENZA IN RECEPTION

E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

STORAGE TABLES CODE CODE

PICTURE

MANUFACTURER HERMAN-MILLER

T1

PRODUCT INFO.

TYPE: CONFERENCE TABLE MODEL: AGL TABLE GROUP SURFACE FINISH: "DP - GEORGIA WHITE MARBLE" BASE: P1/PA "WHITE/ POLISHED ALUMINUM" SIZE: 158" L. X 48" W. X 29" H.

QUANTITY

1

PURCHASE LOCATION REPRESENTATIVE: KRYSTLE SCHOFIELD

PICTURE

NOTES

CONFERENCE/BOARDROOM TABLE LOCATION: GROUP SURVEY ROOM A

MANUFACTURER HERMAN-MILLER

S1

QUANTITY

TYPE: STORAGE TOWER MODEL: TU STORAGE L-SERIES MOBILE PEDESTAL - FILE/FILE FINISH: NO. 79 - "GREEN APPLE" SIZE: 24" D. X 14.5" W. X 27.5" H.

6

PURCHASE LOCATION REPRESENTATIVE: KRYSTLE SCHOFIELD PHONE: (604) 629 - 6996

NOTES

STORAGE PEDESTAL LOCATION: ADMINISTRATIVE ASSISTANTS' OFFICE, ACCOUNT EXECUTIVE OFFICE

ISSUED FOR:

1.

PHASE ONE REVISION INITIALS XXXX

2.

PHASE TWO REVISION INITIALS XXXX

revision

description

BY:

DATE:

E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

PHONE: (604) 629 - 6996

HERMAN-MILLER

E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

PRODUCT INFO.

ISSUE NO.

S2

TYPE: STORAGE TOWER MODEL: TU STORAGE MOBILE PEDESTAL - BOX/BOX/FILE FINISH: 79 - "GREEN APPLE" SIZE: 24" D. X 14.5" W. X 27.5" H.

6

REPRESENTATIVE: KRYSTLE SCHOFIELD PHONE: (604) 629 - 6996

STORAGE PEDESTAL LOCATION: ADMINISTRATIVE ASSISTANTS' OFFICE, ACCOUNT EXECUTIVE OFFICE

E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

HERMAN-MILLER

T2

HERMAN-MILLER

T3

TYPE: CONFERENCE TABLE MODEL: EAMES ROUND CONFERENCE TABLE SURFACE FINISH: "9N - SANTOS PALISANDER" COLUMN FINISH: "WHITE" BASE: CD - POLISHED ALUMINUM SIZE: 84"W. X 28.5" H.

2

REPRESENTATIVE: KRYSTLE SCHOFIELD

CONFERENCE/BOARDROOM TABLE LOCATION: CONFERENCE ROOM, GROUP SURVEY ROOM B

PHONE: (604) 629 - 6996

HERMAN-MILLER

S3

REPRESENTATIVE: KRYSTLE SCHOFIELD PHONE: (604) 629 - 6996 E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

STORAGE PEDESTAL LOCATION: PRESIDENT AND VICE PRESIDENTS' OFFICES. CONFERENCE ROOM, SURVEY ROOM A, SURVEY ROOM B, ADMINISTRATIVE ASSISTANTS' OFFICE

STORAGE TYPE: DINING TABLE MODEL: EAMES ROUND TABLE SURFACE FINISH: "9N - SANTOS PALISANDER" COLUMN FINISH: "WHITE" BASE: CD - POLISHED ALUMINUM SIZE:42"W. X 28.5" H.

2

REPRESENTATIVE: KRYSTLE SCHOFIELD

DINING TABLE LOCATION: BREAK/ BEVERAGE ROOM

CODE

PHONE: (604) 629 - 6996

PICTURE

MANUFACTURER

CH1 TYPE: SIDE TABLE MODEL: POLYGON WIRE TABLE WITH ROUNDED HEXAGONAL SURFACE SURFACE & BASE FINISH: "G1 - GRAPHITE" SIZE: 42"W. X 20" H.

PRODUCT INFO.

QUANTITY

E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

1

REPRESENTATIVE: KRYSTLE SCHOFIELD

DINING TABLE LOCATION: RECEPTION AREA

TYPE: SOFA MODEL: TUXEDO CLASSIC COUCH FINISH: CROSSING WEAVE. " GREEN APPLE - 8T13" BASE & FRAME FINISH: "CHR - CHROME" SIZE: 28" D. X 84" W. X 30" H.

4

PURCHASE LOCATION REPRESENTATIVE: KRYSTLE SCHOFIELD PHONE: (604) 629 - 6996

NOTES

STORAGE PEDESTAL LOCATION: ADMINISTRATIVE ASSISTANTS' OFFICE, ACCOUNT EXECUTIVE OFFICE

E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

TYPE: WORK TABLE MODEL: OFFICINA FRATINO TABLE SURFACE & BASE FINISH: "G1 - GRAPHITE" SIZE: 25.5" W. X 63" H. X 29.5"

1

REPRESENTATIVE: KRYSTLE SCHOFIELD

DINING TABLE LOCATION: WORK ROOM

FURNITURE NOTES

PHONE: (604) 629 - 6996

T5

-

E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

HERMAN-MILLER

T5

TYPE: COFFEE TABLE MODEL: EAMES WIRE BASED ELLIPTICAL TABLE SURFACE FINISH: NO. 98 "STUDIO WHITE" BASE FINISH: NO. 47 "TRIVALENT CHROME" SIZE: 29.5" D. X 10" H. X 89" W.

1

REPRESENTATIVE: KRYSTLE SCHOFIELD

DINING TABLE LOCATION: PRESIDENT'S OFFICE

-

ALL MATERIALS SHOULD ARRIVE ON SITE IN ORIGINAL PACKAGING CONTRACTOR MUST CHECK THE CONDITION OF MATERIALS UPON DELIVERY SUBMIT SAMPLES OF FURNITURE MATERIAL FOR APPROVAL

PHONE: (604) 629 - 6996

TYPE: COFFEE TABLE MODEL: NOGUCHI TABLE SURFACE FINISH: GLASS BASE FINISH: "PLATINUM ASH" SIZE: 50" W. X 15.75" H. X 36"D

2

REPRESENTATIVE: KRYSTLE SCHOFIELD

· · · · · ·

MARKET RESEARCH GROUP 7785 WEST HASTINGS STREET VANCOUVER, BC

DINING TABLE LOCATION: PRESIDENT'S OFFICE, VICE PRESIDENTS' OFFICES

PHONE: (604) 629 - 6996 E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

TITLE:

FURNITURE SPECIFICATION

GENERAL NOTES ·

PROJECT:

E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

HERMAN-MILLER

date

1090 W.GEORGIA ST. VANCOUVER, BC V6E 3V7 TEL. (604) 270 - 4710

E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

HERMAN-MILLER

by

JH|DESIGNS

PHONE: (604) 629 - 6996

T4

T6

7

E-MAIL: KRYSTLE_SCHOFIELD@HERMANMILLER.COM

HERMAN-MILLER

HERMAN-MILLER

TYPE: STORAGE MODEL: 3 UNIT H-FRAME CREDENZA TOP, DRAWERS & DOOR FINISH: "PLATINUM ASH" BASE & FRAME FINISH: "CHR - CHROME" SIZE: 92" W. X 14" D. X 26.5" H.

ALL WORKMANSHIP AND METHODS OF CONSTRUCTION TO MEET REQUIREMENTS OF THE CURRENT EDITION OF THE BRITISH COLUMBIA BUILDING CODE AND CITY OF VANCOUVER BYLAWS CONTRACTOR TO CONFIRM DIMENSIONS ON SITE PRIOR TO COMMENCING CONSTRUCTION. DISCREPANCIES TO BE REPORTED TO THE DESIGNER PRIOR TO PROCEEDING. WRITTEN DIMENSIONS TO TAKE PRECEDENCE OVER SCALED DIMENSIONS REMOVED MATERIAL AND PRODUCTS TO BE DISPOSED OF OR SALVAGED AS DIRECTED BY OWNER ACCESS TO SITE AND WORK SCHEDULE TO BE COORDINATED WITH DESIGNER KEEP SITE CLEAN AND MAINTAIN SAFETY OF PUBLIC DURING DEMOLITION, CONSTRUCTION. BLOCK AND BRACE AS REQUIRED ALL MATERIALS SHOULD ARRIVE ON SITE IN ORIGINAL PACKAGING CONTRACTOR MUST CHECK THE CONDITION OF MATERIALS UPON DELIVERY

NOTE: · SITE MEASUREMENTS REQUIRED. ALL CONTRACTORS SHALL VERIFY ON-SITE CONDITIONS, DIMENSIONS, DRAWINGS, DETAILS AND SPECIFICATIONS AND REPORT ALL ERRORS AND OMISSIONS TO THE DESIGNER BEFORE PROCEEDING WITH WORK. · DO NOT SCALE THE DRAWINGS. THESE DRAWINGS REMAIN THE PROPERTY OF THE DESIGNER. · GENERAL CONTRACTOR TO VISIT SITE PRIOR TO PRICING AND CONSTRUCTION TO DETERMINE EXTENT OF EXISTING T-BAR CEILING AND ACOUSTIC TILE TO BE REMOVED AND/OR DEMOLISHED TO ACCOMMODATE NEW CONSTRUCTION. · ALL CEILING COMPONENTS AND MECHANICAL/ ELECTRICAL DEVICES TO BE INSTALLED TO SEISMIC REQUIREMENTS OF BC. · CEILING HEIGHTS AS NOTED ON PLAN

ID-009 1

FURNITURE SPECIFICATIONS SCALE: NTS

DATE:

AUGUST 6, 2015

SCALE:

NTS

DRAWN BY:

JENNIFER HEINRICH

DRAWING NO.

ID-009


COPYRIGHT RESERVED: This drawing and design are, and at all times remain, the exclusive property of Jennifer Heinrich, and can be reproduced only with written consent. This drawing must not be scaled. Contractors shall verify all dimensions prior to commencement of work, and any omissions or discrepancies shall be reported to the Designer.

17'-1121" 12'-278"

1178"

858"

4"

FLOORLINE

T1

2'-141"

2'-0"

4"

2'-721"

1'-0"

BB1

1'-034"

3'-2"

2'-0"

REF.

3/4" THK. ACRYLIC DOORS IN "WIRED MERCURY" FINISH BY KITCHEN CRAFT CABINETRY ALEXANDRIA BASEBOARD IN WHITE BY ALEXANDRIA MOULDING 4"

3'-0"

2

ID-011

2'-3" X 5'-8" SPACE FOR REFRIGERATOR

3'-2"

1138"

2'-621"

2'-0"

4"

12'-278"

4"

CM1

LUNCHROOM ELEVATION (RM 115) A-A

1 ID-010

LUNCHROOM ELEVATION (RM 115) B-B

2 ID-010

SCALE: 1/2" = 1'-0"

SCALE: 1/2" = 1'-0"

CELING LINE ALEXANDRIA CROWN MOULDING IN WHITE BY ALEXANDRIA MOULDING KUZCO CHANDELIER MOUNTED 6'6" AFF.

CELING LINE

P1

4'-6"

MARKET RESEARCH GROUP

LOGO BACKLIT WITH LED STRIP LIGHTS BY ART SIGNS

P1

4'-6"

ALEXANDRIA CROWN MOULDING IN WHITE BY ALEXANDRIA MOULDING KUZCO CHANDELIER MOUNTED 6'6" AFF.

T1 BB1

17'-1121"

CM1

3'-221"

1'-021"

FAUCET BY RICHELIEU NO. 2839140906 IN CHROME AND ANTHRACITE FINSIH 2" THK. STRAIGHT EDGE ECO CRUSH COUNTERTOP IN WINTER FINISH BLANCO PRECIS SINK WITH WASHBOARD BY RICHELIEU NO. 28403106 IN ANTHRACITE FINISH

FLOORLINE 23" X 31" SPACE FOR D.W.

1121" 1021"

3'-0"

1/2" THK. ADJ. PLYWOOD SHELVES ALEXANDRIA BASEBOARD IN WHITE BY ALEXANDRIA MOULDING

EQ.

3'-0"

8" X 13" TILED BACKSPLASH FROM FONTILE- MANHATTAN CERAMIC TILE IN "GRIS"

HARDWARE BY RICHELIEU NO. BP4789 IN CHROME FINISH

ID-011

1'-885"

P1

1/2" THK. ADJ. PLYWOOD SHELVES

921"

EQ. EQ.

621" 981"

1

ALEXANDRIA CROWN MOULDING IN WHITE BY ALEXANDRIA MOULDING

8" X 13" TILED BACKSPLASH FROM FONTILE - MANHATTAN CERAMIC TILE IN "GRIS" 2" THK. STRAIGHT EDGE ECO CRUSH COUNTERTOP IN WINTER FINISH HARDWARE BY RICHELIEU NO. BP4789 IN CHROME FINISH

F

DW

3/4" THK. ACRYLIC DOORS IN "WIRED MERCURY" FINISH BY KITCHEN CRAFT CABINETRY

4"

1'-0"

1'-134"

1'6" X 2'-0" COFEE MAKER

3/4" THK. ACRYLIC DOORS IN "WIRED MERCURY" FINISH WITH 1/2" FROSTED GLASS PANEL BY KITCHEN CRAFT CABINETRY

2'-185"

2'-4"

4"

2'-034"

1'-021"

1021"

3'-683"

4"

ALEXANDRIA CROWN MOULDING IN WHITE BY ALEXANDRIA MOULDING

3/4" THK. ACRYLIC DOORS IN "WIRED MERCURY"FINISH WITH 1/2" FROSTED GLASS PANEL BY KITCHEN CRAFT CABINETRY

1121"

3'-221"

1'-0"

MW

2'-0"

8'-6"

P1

CELING LINE

721"

CELING LINE

1141"

4"

1'-8"

4'-643"

EQ.

1181"

EQ.

921"

EQ.

321"

EQ.

841"

1'-058"

POLISHED STRAIGHT EDGE EDGE LEDGE AND COUNTER IN WHITE GRANITE FROM ATLAS STONE

P1

ISSUE NO.

ISSUED FOR:

1.

PHASE ONE REVISION INITIALS XXXX

2.

PHASE TWO REVISION INITIALS XXXX

revision

description

BY:

DATE:

ENGINEERED WOOD WITH 1/8" THK. WOOD VENEER IN SELECTED FINISH BY OSCAR GRANNS

WC1

943"

EQ.EQ. EQ. EQ.

2"

ID-011

521"

3

HARDWARE BY RICHELIEU NO.2024 IN CLEAR AND BRUSHED NICKEL FINISH

4

2"

G

10"

1'-0"

2"

CONCRETE 3D WALL TILE FROM ARCHIPRODUCTS/ KAZA CONCRETE - "TRE" IN BLACK FINISH

1134"

8'-6"

8'-578"

RECEPTIONIST DESK WITH POLISHED WHITE SOLID SURFACE STRAIGHT EDGE LEDGE FROM COSENTINO

ID-011

2'-8"

3/4" THK. ENGINEERED WOOD WITH1/8" THK.WOOD VENEER IN SELECTED FINISH BY OSCAR GRANNS

1'-2"

2'-10"

WOOD LOOK 5-3/4" X 46-7/8" PORCELAIN TILE FROM DAL-TILE NO. SW05 IN "SNOW PINE" FINISH

3'-0"

3'-10"

10"

1/2" THK. ADJ. PLYWOOD SHELVES

4"

ALEXANDRIA BASEBOARD IN WHITE BY ALEXANDRIA MOULDING

1'-0"

FLOORLINE

1'-8"

841"

4'-241"

1'-3"

5'-981"

14'-381"

3 ID-011

ALEXANDRIA BASEBOARD IN WHITE BY ALEXANDRIA MOULDING FLOORLINE

841"

C1

C1

BB1

BB1

CM1

CM1

RECEPTIONIST DESK ELEVATION (RM 101) C-C SCALE: 1/2" = 1'-0"

4 ID-011

8"

2'-558"

1'-0"

1'-6"

1'-1"

4'-558"

2'-7"

2'-6"

date

JH|DESIGNS 1090 W.GEORGIA ST. VANCOUVER, BC V6E 3V7 TEL. (604) 270 - 4710

4"

10'-634"

RECEPTIONIST DESK ELEVATION (RM 101) D-D

by

PROJECT:

SCALE: 1/2" = 1'-0"

MARKET RESEARCH GROUP 7785 WEST HASTINGS STREET VANCOUVER, BC

GENERAL NOTES · · · · · · · · ·

ALL WORKMANSHIP AND METHODS OF CONSTRUCTION TO MEET REQUIREMENTS OF THE CURRENT EDITION OF THE BRITISH COLUMBIA BUILDING CODE AND CITY OF VANCOUVER BYLAWS CONTRACTOR TO CONFIRM DIMENSIONS ON SITE PRIOR TO COMMENCING CONSTRUCTION. DISCREPANCIES TO BE REPORTED TO THE DESIGNER PRIOR TO PROCEEDING. WRITTEN DIMENSIONS TO TAKE PRECEDENCE OVER SCALED DIMENSIONS REMOVED MATERIAL AND PRODUCTS TO BE DISPOSED OF OR SALVAGED AS DIRECTED BY OWNER ACCESS TO SITE AND WORK SCHEDULE TO BE COORDINATED WITH DESIGNER KEEP SITE CLEAN AND MAINTAIN SAFETY OF PUBLIC DURING DEMOLITION, CONSTRUCTION. BLOCK AND BRACE AS REQUIRED ALL MATERIALS SHOULD ARRIVE ON SITE IN ORIGINAL PACKAGING CONTRACTOR MUST CHECK THE CONDITION OF MATERIALS UPON DELIVERY USE ONLY MOST REVISED DRAWINGS REPORT ALL ERRORS OR OMISSIONS TO THE DESIGNER, ARCHITECT OR ENGINEER

NOTE:

NOTES ·

ALL HARDWARE BY RICHELIEU, SPECIFICATIONS TO COME

·

OWNER TO SPECIFY APPLIANCES

·

SEE FINISHES PLAN FOR ABBREVIATIONS: PG. ID-007

·

SEE DOOR SCHEDULE FOR DOOR TYPES: PG. ID-005

·

SEE LIGHTING PLAN FOR LIGHT FIXTURE SPECIFICATIONS: PG. ID-006

TITLE:

ELEVATIONS

DATE:

AUGUST 6, 2015

·

SITE MEASUREMENTS REQUIRED. ALL CONTRACTORS SHALL VERIFY ON-SITE CONDITIONS, DIMENSIONS, DRAWINGS, DETAILS AND SPECIFICATIONS AND REPORT ALL ERRORS AND OMISSIONS TO THE DESIGNER BEFORE PROCEEDING WITH WORK.

SCALE:

1/2" = 1'-0"

·

DO NOT SCALE THE DRAWINGS. THESE DRAWINGS REMAIN THE PROPERTY OF THE DESIGNER.

DRAWN BY:

JENNIFER HEINRICH

·

GENERAL CONTRACTOR TO VISIT SITE PRIOR TO PRICING AND CONSTRUCTION TO DETERMINE EXTENT OF EXISTING T-BAR CEILING AND ACOUSTIC TILE TO BE REMOVED AND/OR DEMOLISHED TO ACCOMMODATE NEW CONSTRUCTION.

DRAWING NO.

·

ALL CEILING COMPONENTS AND MECHANICAL/ ELECTRICAL DEVICES TO BE INSTALLED TO SEISMIC REQUIREMENTS OF BC.

·

CEILING HEIGHTS AS NOTED ON PLAN

ID-010


CEILING LINE 2"

1/2" WATER RESISTANT GWB 8" X 13" TILED BACKSPLASH FROM FONTILE - MANHATTAN CERAMIC TILE IN "GRIS" FAUCET BY RICHELIEU NO. 2839140906 IN CHROME AND ANTHRACITE FINSIH

1/2" WATER RESISTANT GWB

WOOD LOOK 5-3/4" X 46-7/8" PORCELAIN TILE FROM DAL-TILE - NO. SW05 IN "SNOW PINE" FINISH

821"

ENGINEERED WOOD WITH 1/8" THK. WOOD VENEER IN SELECTED FINISH BY OSCAR GRANNS

3'-3"

HARDWARE BY RICHELIEU NO.2024 IN CLEAR AND BRUSHED NICKEL FINISH

2" 2'-6" 4"

ENGINEERED WOOD WITH 1/8" THK. WOOD VENEER IN SELECTED FINISH BY OSCAR GRANNS HARDWARE BY RICHELIEU NO.2024 IN CLEAR AND BRUSHED NICKEL FINISH 3/4" THK. BASE WITH 1/8" THK. WOOD VENEER SELECTED FINISH BY OSCAR GRANNS 2"X4" HARDWOOD FRAME

FLOOR LINE

3"

2'-0"

FLOOR LINE

434"

ID-011

RECEPTION SECTION (RM 101) SCALE: 1/2" = 1'-0"

1.

PHASE ONE REVISION INITIALS XXXX

2.

PHASE TWO REVISION INITIALS XXXX

revision

description

BY:

DATE:

1/2" THK. PLYWOOD SHELVES WITH 1/8" THK. WOOD VENEER IN SELECTED FINISH BY OSCAR GRANNS CONCRETE 3D WALL TILE FROM ARCHIPRODUCTS/ KAZA CONCRETE "TRE" IN BLACK FINISH

3"

2'-0"

434"

by

date

JH|DESIGNS

2'-981"

2'-981"

3

ISSUED FOR:

ENGINEERED WOOD WITH 1/8" THK. WOOD VENEER IN SELECTED FINISH BY OSCAR GRANNS

2"

2"X4" HARDWOOD FRAME

4"

1'-0"

3/4" THK. BASE WITH 1/8" THK. WOOD VENEER SELECTED FINISH BY OSCAR GRANNS 2"X4" HARDWOOD FRAME

RECEPTIONIST DESK WITH POLISHED WHITE GRANITE LEDGE FROM ATLAS STONE

ISSUE NO.

1'-0"

ENGINEERED WOOD WITH 1/8" THK. WOOD VENEER IN SELECTED FINISH BY OSCAR GRANNS

SCALE: 1/2" = 1'-0"

10"

2" 1'-0"

2"X4" HARDWOOD FRAME

4" 1"2"

RECEPTIONIST DESK WITH POLISHED STRAIGHT EDGE WHITE GRANITE COUNTER AND LEDGE FROM ATLAS STONE

10"

ID-011

4" 1"2"

SCALE: 1/2" = 1'-0"

LUNCH ROOM SECTION (ROOM 115)

4"

ID-011

2

5"

3'-3"

LUNCH ROOM SECTION (RM 115)

1'-934"

821"

1178" 321"

FLOOR LINE

1'-0"

621" 981" 3'-0"

1

3/4" THK. ACRYLIC DOORS IN "WIRED MERCURY" FINISH BY KITCHEN CRAFT CABINETRY 3/4" THK. KICK BOARD IN SELECTED FINISH WITH 2" X 4" HARDWOOD FRAME

FLOOR LINE

1'-934"

2'-0"

HARDWARE BY RICHELIEU NO. BP4789 IN CHROME FINISH 1/2" THK. PLYWOOD BACKING 1/2" X 2-1/2" SPACERS

1/2" X 2-1/2" SPACERS 3/4" THK. ACRYLIC DOORS IN "WIRED MERCURY" FINISH BY KITCHEN CRAFT CABINETRY 3/4" THK. KICK BOARD IN SELECTED FINISH WITH 2" X 4" HARDWOOD FRAME

1'-858"

5"

2" THK. STRAIGHT EDGE ECO CRUSH COUNTERTOP IN WINTER FINISH 1/2" X 1" DOOR STOPPER

2" THK. STRAIGHT EDGE ECO CRUSH COUNTERTOP IN WINTER FINISH 1/2" X 1" DOOR STOPPER HARDWARE BY RICHELIEU NO. BP4789 IN CHROME FINISH 1/2" THK. ADJ. SHELF

2'-0"

2'-0"

BLANCO PRECIS SINK WITH WASHBOARD BY RICHELIEU NO. 28403106 IN ANTHRACITE FINISH

2'-0"

8'-6"

1'-058"

8'-6"

2"

1'-0"

ALEXANDRIA CROWN MOULDING IN WHITE BY ALEXANDRIA MOULDING

1/2" THK. PLYWOOD BACKING 8" X 13" TILED BACKSPLASH FROM FONTILE - MANHATTAN CERAMIC TILE IN "GRIS"

1121"

3'-2"

1-0"

ALEXANDRIA CROWN MOULDING IN WHITE BY ALEXANDRIA MOULDING 3/4" THK. ACRYLIC DOORS IN "WIRED MERCURY"FINISH WITH 1/2" FROSTED GLASS PANEL BY KITCHEN CRAFT CABINETRY

3'-2"

321"

CEILING LINE

1021"

COPYRIGHT RESERVED: This drawing and design are, and at all times remain, the exclusive property of Jennifer Heinrich, and can be reproduced only with written consent. This drawing must not be scaled. Contractors shall verify all dimensions prior to commencement of work, and any omissions or discrepancies shall be reported to the Designer.

4 ID-011

1090 W.GEORGIA ST. VANCOUVER, BC V6E 3V7 TEL. (604) 270 - 4710

RECEPTION SECTION (RM 101) SCALE: 1/2" = 1'-0"

PROJECT:

MARKET RESEARCH GROUP 7785 WEST HASTINGS STREET VANCOUVER, BC

GENERAL NOTES · · · · · · · · ·

ALL WORKMANSHIP AND METHODS OF CONSTRUCTION TO MEET REQUIREMENTS OF THE CURRENT EDITION OF THE BRITISH COLUMBIA BUILDING CODE AND CITY OF VANCOUVER BYLAWS CONTRACTOR TO CONFIRM DIMENSIONS ON SITE PRIOR TO COMMENCING CONSTRUCTION. DISCREPANCIES TO BE REPORTED TO THE DESIGNER PRIOR TO PROCEEDING. WRITTEN DIMENSIONS TO TAKE PRECEDENCE OVER SCALED DIMENSIONS REMOVED MATERIAL AND PRODUCTS TO BE DISPOSED OF OR SALVAGED AS DIRECTED BY OWNER ACCESS TO SITE AND WORK SCHEDULE TO BE COORDINATED WITH DESIGNER KEEP SITE CLEAN AND MAINTAIN SAFETY OF PUBLIC DURING DEMOLITION, CONSTRUCTION. BLOCK AND BRACE AS REQUIRED ALL MATERIALS SHOULD ARRIVE ON SITE IN ORIGINAL PACKAGING CONTRACTOR MUST CHECK THE CONDITION OF MATERIALS UPON DELIVERY USE ONLY MOST REVISED DRAWINGS REPORT ALL ERRORS OR OMISSIONS TO THE DESIGNER, ARCHITECT OR ENGINEER

NOTE:

NOTES ·

ALL HARDWARE BY RICHELIEU, SPECIFICATIONS TO COME

·

OWNER TO SPECIFY APPLIANCES

·

SEE FINISHES PLAN FOR ABBREVIATIONS: PG. ID-007

·

SEE DOOR SCHEDULE FOR DOOR TYPES: PG. ID-005

·

SEE LIGHTING PLAN FOR LIGHT FIXTURE SPECIFICATIONS: PG. ID-006

TITLE:

SECTIONS

DATE:

AUGUST 6, 2015

·

SITE MEASUREMENTS REQUIRED. ALL CONTRACTORS SHALL VERIFY ON-SITE CONDITIONS, DIMENSIONS, DRAWINGS, DETAILS AND SPECIFICATIONS AND REPORT ALL ERRORS AND OMISSIONS TO THE DESIGNER BEFORE PROCEEDING WITH WORK.

SCALE:

1/2" = 1'-0"

·

DO NOT SCALE THE DRAWINGS. THESE DRAWINGS REMAIN THE PROPERTY OF THE DESIGNER.

DRAWN BY:

JENNIFER HEINRICH

·

GENERAL CONTRACTOR TO VISIT SITE PRIOR TO PRICING AND CONSTRUCTION TO DETERMINE EXTENT OF EXISTING T-BAR CEILING AND ACOUSTIC TILE TO BE REMOVED AND/OR DEMOLISHED TO ACCOMMODATE NEW CONSTRUCTION.

DRAWING NO.

·

ALL CEILING COMPONENTS AND MECHANICAL/ ELECTRICAL DEVICES TO BE INSTALLED TO SEISMIC REQUIREMENTS OF BC.

·

CEILING HEIGHTS AS NOTED ON PLAN

ID-011


COPYRIGHT RESERVED: This drawing and design are, and at all times remain, the exclusive property of Jennifer Heinrich, and can be reproduced only with written consent. This drawing must not be scaled. Contractors shall verify all dimensions prior to commencement of work, and any omissions or discrepancies shall be reported to the Designer.

2" THK. STRAIGHT EDGE ECO CRUSH COUNTERTOP IN WINTER FINISH 1/2" X 1" DOOR STOPPER 2"

3/4" THK. ACRYLIC DOORS IN "WIRED MERCURY" FINISH BY KITCHEN CRAFT CABINETRY 1"

HARDWARE BY RICHELIEU NO. BP4789 IN CHROME FINISH

1 " 2

3/4" THK. ACRYLIC DOORS IN "WIRED MERCURY" FINISH BY KITCHEN CRAFT CABINETRY

3 " 4

1 " 2

SHELVING SPACE WITH 1/2" THK. PLYWOOD BACKING

1/2" X 1" DOOR STOPPER 3/4" THK. KICK BOARD IN SELECTED FINISH 2" X 4" HARDWOOD FRAME

3 " 4 4"

3 " 7 " 4 8

COUNTERTOP DETAIL (RM 115)

1 ID-012

2"

SCALE: 3" = 1'-0"

3 " 4

FLOOR LINE

KITCHEN BASEBOARD DETAIL (RM 115)

2

ID-012

SCALE: 3" = 1'-0"

ISSUE NO.

ISSUED FOR:

1.

PHASE ONE REVISION INITIALS XXXX

2.

PHASE TWO REVISION INITIALS XXXX

revision

description

BY:

DATE:

2" THK. POLISHED STRAIGHT EDGE WHITE GRANITE COUNTER FROM ATLAS STONE 1/2" X 1" DOOR STOPPER WITH 1/8' THK. VENEER IN SELECTED FINISH BY

2" THK. POLISHED STRAIGHT EDGE WHITE GRANITE COUNTER FROM ATLAS STONE

DRAWER WITH 1/2" THK. PLYWOOD BACKING AND BOTTOM

1/2" THK. PLYWOOD SHELVES WITH 1/8" THK. WOOD VENEER IN SELECTED FINISH BY OSCAR GRANNS

HARDWARE BY RICHELIEU NO.2024 IN CLEAR AND BRUSHED NICKEL FINISH

CONCRETE 3D WALL TILE FROM ARCHIPRODUCTS/ KAZA CONCRETE "TRE" IN BLACK FINISH

1"

214"

1 " 2

1 " 2

218"

312"

2"

ENGINEERED WOOD WITH 1/8" THK. WOOD VENEER IN SELECTED FINISH BY OSCAR GRANNS 1/2" X 1" DOOR STOPPER WITH 1/8' THK. VENEER IN SELECTED FINISH BY OCAR GRANNS HARDWARE BY RICHELIEU NO.2024 IN CLEAR AND BRUSHED NICKEL FINISH

3/4" THK. ENGINEERED WOOD WITH 1/8" THK. WOOD VENEER IN SELECTED FINISH BY OSCAR GRANNS

614"

3 "1 " 4 2

RECEPTION DESK COUNTER DETAIL (RM 101)

3 ID-012

SCALE: 3" = 1'-0"

3 ID-012

by

date

JH|DESIGNS

3 "1 1 4 2" 4"

1090 W.GEORGIA ST. VANCOUVER, BC V6E 3V7 TEL. (604) 270 - 4710

RECEPTION DESK COUNTER DETAIL (RM 101) SCALE: 3" = 1'-0"

PROJECT:

MARKET RESEARCH GROUP 7785 WEST HASTINGS STREET VANCOUVER, BC

GENERAL NOTES · · · · · · · · ·

ALL WORKMANSHIP AND METHODS OF CONSTRUCTION TO MEET REQUIREMENTS OF THE CURRENT EDITION OF THE BRITISH COLUMBIA BUILDING CODE AND CITY OF VANCOUVER BYLAWS CONTRACTOR TO CONFIRM DIMENSIONS ON SITE PRIOR TO COMMENCING CONSTRUCTION. DISCREPANCIES TO BE REPORTED TO THE DESIGNER PRIOR TO PROCEEDING. WRITTEN DIMENSIONS TO TAKE PRECEDENCE OVER SCALED DIMENSIONS REMOVED MATERIAL AND PRODUCTS TO BE DISPOSED OF OR SALVAGED AS DIRECTED BY OWNER ACCESS TO SITE AND WORK SCHEDULE TO BE COORDINATED WITH DESIGNER KEEP SITE CLEAN AND MAINTAIN SAFETY OF PUBLIC DURING DEMOLITION, CONSTRUCTION. BLOCK AND BRACE AS REQUIRED ALL MATERIALS SHOULD ARRIVE ON SITE IN ORIGINAL PACKAGING CONTRACTOR MUST CHECK THE CONDITION OF MATERIALS UPON DELIVERY USE ONLY MOST REVISED DRAWINGS REPORT ALL ERRORS OR OMISSIONS TO THE DESIGNER, ARCHITECT OR ENGINEER

NOTE:

NOTES ·

ALL HARDWARE BY RICHELIEU, SPECIFICATIONS TO COME

·

OWNER TO SPECIFY APPLIANCES

·

SEE FINISHES PLAN FOR ABBREVIATIONS: PG. ID-007

·

SEE DOOR SCHEDULE FOR DOOR TYPES: PG. ID-005

·

SEE LIGHTING PLAN FOR LIGHT FIXTURE SPECIFICATIONS: PG. ID-006

TITLE:

DETAIL DRAWINGS

DATE:

AUGUST 6, 2015

·

SITE MEASUREMENTS REQUIRED. ALL CONTRACTORS SHALL VERIFY ON-SITE CONDITIONS, DIMENSIONS, DRAWINGS, DETAILS AND SPECIFICATIONS AND REPORT ALL ERRORS AND OMISSIONS TO THE DESIGNER BEFORE PROCEEDING WITH WORK.

SCALE:

3" = 1'-0"

·

DO NOT SCALE THE DRAWINGS. THESE DRAWINGS REMAIN THE PROPERTY OF THE DESIGNER.

DRAWN BY:

JENNIFER HEINRICH

·

GENERAL CONTRACTOR TO VISIT SITE PRIOR TO PRICING AND CONSTRUCTION TO DETERMINE EXTENT OF EXISTING T-BAR CEILING AND ACOUSTIC TILE TO BE REMOVED AND/OR DEMOLISHED TO ACCOMMODATE NEW CONSTRUCTION.

DRAWING NO.

·

ALL CEILING COMPONENTS AND MECHANICAL/ ELECTRICAL DEVICES TO BE INSTALLED TO SEISMIC REQUIREMENTS OF BC.

·

CEILING HEIGHTS AS NOTED ON PLAN

ID-012