Safety instructions

Next Article
Maintenance

Maintenance

Caution

● Do not touch a rotating part

Advertisement

A pump shaft and a motor shaft may be coupled barely. Be sure to cover the coupling in order to reduce the risk of personal injury which may occur as coming in contact with the coupling in operation.

● Take countermeasures against static electricity

When low electric conductivity liquids such as ultra-pure water and fluor inactive liquid (e.g. FluorinertTM) are handled, the static electricity may be generated in the pump and may cause static discharge.

● Conduct degassing before load operation

Always prime the pump and remove air before operation. Make sure that air is completely expelled from both the discharge and suction lines. Especially, the air in the suction line can cause dry running and damage sliding parts when it enters the pump at once. Note that hydrogen peroxide and sodium hypochlorite easily generate gas and degassing is needed frequently.

● Do not incinerate plastic parts

Fluoroplastic parts are used in this product. Throwing fluoroplastics into the fire is accompanied with harmful gas. Dispose of fluoroplastics as an incombustible.