Chapter 4 Software Index

Some examples in auto_run mode as follows: (A) Single Cycle Running (13-00= 1, 4) The inverter will run for a single full cycle based upon the specified setting mode. Then, it will stop. ‧ For example: 13-00=1 (or 4) ‧ Panel Frequency (3-01)=15 Hz

13-01=30Hz

13-16=20s 13-32=1 ‧

13-04~13-15=0Hz ,

13-17=25s 13-33=1

13-02=50Hz

13-03=20Hz

13-18=30s

13-19=40s

13-34=1(FWD) 13-35=2(REV)

13-20~13-31=0s , 13-36~13-47=0

Figure 4-29 Single cycle auto run

(B) Periodic cycle Running (13-00=2, 5) The inverter will repeat the same cycle periodically. For example: 13-00=2 (or 5) 13-01~13-15,13-16~13-31,13-32~13-47 : Same setting as the example (A)

Figure 4-30 Periodic cycle auto run