NEMO|etc.® TABLE 1B: DELTA SHINGLE OR SLATE (NAIL TAB) WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OF) OR RECOVER System No.
Deck (Note 1)
Fire Barrier / Underlay
Panel Attachment Panel Fasteners (Notes 5 & Note 7)
Clips
Fasteners per Clip
Fasteners per Tab
3
2
1
Min. 1.5” x 0.155” diameter aluminum ring shank nails with min. ½” diameter heads or Min. 1.5” x 0.122” diameter galvanized ring shank nails with 7/16” diameter heads
9.
Min. 15/32” APA rated plywood
Note 3
Aluminum or Steel
MDP (psf)
-180.0
TABLE 2: DELTA DIAMOND WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OF) OR RECOVER
System No.
10.
Deck (Note 1)
Min. 15/32” APA rated plywood
Fire Barrier / Underlay
Note 3
NEMO ETC, LLC Certificate of Authorization #9503 ©2019 NEMO ETC, LLC
Panel Attachment Panel
Aluminum or Steel
Fasteners (Notes 5 & Note 7)
Min. 1.5” x 0.148” diameter aluminum ring shank nails with min. ½” diameter heads or min. 1.5” x 0.122” diameter galvanized ring shank nails with 7/16” diameter heads
Clips
Fasteners per Clip
Fasteners per Shingle Tab
None
N/A
1
P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ Delta Metal Roof Systems; (604) 953-1000 TOP OF APPENDIX 1
Drawing
MDP (psf)
-30.0