Florida FL7263-R7

Page 10

NEMO|etc.® TABLE 1B: DELTA SHINGLE OR SLATE (NAIL TAB) WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OF) OR RECOVER System No.

Deck (Note 1)

Fire Barrier / Underlay

Panel Attachment Panel Fasteners (Notes 5 & Note 7)

Clips

Fasteners per Clip

Fasteners per Tab

3

2

1

Min. 1.5” x 0.155” diameter aluminum ring shank nails with min. ½” diameter heads or Min. 1.5” x 0.122” diameter galvanized ring shank nails with 7/16” diameter heads

9.

Min. 15/32” APA rated plywood

Note 3

Aluminum or Steel

MDP (psf)

-180.0

TABLE 2: DELTA DIAMOND WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OF) OR RECOVER

System No.

10.

Deck (Note 1)

Min. 15/32” APA rated plywood

Fire Barrier / Underlay

Note 3

NEMO ETC, LLC Certificate of Authorization #9503 ©2019 NEMO ETC, LLC

Panel Attachment Panel

Aluminum or Steel

Fasteners (Notes 5 & Note 7)

Min. 1.5” x 0.148” diameter aluminum ring shank nails with min. ½” diameter heads or min. 1.5” x 0.122” diameter galvanized ring shank nails with 7/16” diameter heads

Clips

Fasteners per Clip

Fasteners per Shingle Tab

None

N/A

1

P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ Delta Metal Roof Systems; (604) 953-1000 TOP OF APPENDIX 1

Drawing

MDP (psf)

-30.0

PEER-DBP-001.A.R6 for FL7263-R7 Revision 6: 08/06/2023 Appendix 1, Page 5 of 8