Offshore & Marine Cable Catalogue
INTERKAB Offshore and Marine Publication Contents Introduction to Your Local and International Cable Partner What We Do Company Details Interkab Offshore Product Range UKOOA Instrumentation, Power and Control Cable Coding IEC Standards and Tests Norwegian and International Marine Specification Cables Materials – Abbreviations – Code Designations Index
FPAL Verify
Verified
No.10049350
ABS
INTERKAB Introduction to Your Local and International Cable Partner INTERKAB is the brand name of International Cable Management, a privately owned group of companies, with its headquarters based in Aberdeen. It is a leading service company in the management and supply of a diverse range of Electrical Cables including power, control, instrument, fibre optic and underwater, together with associated electrical products, to the global oil and gas industry. The company has built a strong and distinctive reputation with a strong foundation including the management team which has been associated with both the OGP industry and its products since the early days of the North Sea, some 40 years.
FPAL Verify
Verified
No.10049350
ABS
What We Do INTERKAB is both local and international, and operates from key oil and gas hubs across the globe. The company operates three distinct divisions across all its operations: Projects; Distribution and Exports. Projects INTERKAB and its employees have a wealth of knowledge and success in managing major Greenfield and Brownfield projects both offshore and onshore, firstly in the North Sea in the early 80s and more recently in China, Iraq and Russia. After-sales service through the life of the project duration operation is standard practice. Distribution and Exports INTERKAB provide a 24/7 service to the industry in supporting clients daily maintenance, operational and repair and urgent requirements from our stock or alternatively we source. If products require to be manufactured, we provide a quick delivery service of 4-6 weeks, and in some instances shorter delivery times. Commitment to customer service and to go the extra mile if need be is common practice in INTERKAB. BS EN ISO 9001 INTERKAB is assessed and approved to the latest BS EN ISO standard, as too are our manufacturers.
FPAL Verify
Verified
No.10049350
ABS
INTERKAB Company Details INTERKAB House Links Place Aberdeen AB11 5DY Tel 44 1224 595640 Fax 44 1224 594416 e-mail: sales@interkab.com website: www.interkab.com
FPAL Verify
Verified
No.10049350
ABS
INTERKAB Offshore Product Range INTERKAB stock and supply a broad range of offshore products across a range of International standards. These products are primarily used in Offshore and marine installations including Production platforms (fixed and floating); Drilling Rigs and Drilling Ships; FPSO & FSO Vessels and other offshore and marine equipment. Our offshore product range includes: LV Power and Control Instrumentation Data Communications CCTV Medium Voltage Subsea Underwater Composite Cables Network Cable Optical Fibre High Temperature
Offshore Specifications BS6883 | BS7917 | NEK606 | IEC61892-4 | IEC60092 | XI | XAI |IEEE 45 INTERKAB is also vastly experienced in contract manufacturing client or project specific cables.
Onshore Cables and Electrical products and accessories INTERKAB supplies the full range of products to meet companies’ onshore requirements for both the oil and gas industry and other associated industries.
FPAL Verify
Verified
No.10049350
ABS
UKOOA Instrumentation, Power and Control Cable Coding W 1st Character
Fire Performance and Voltage Rating
2nd Character
Cable Construction
3rd Character
No. of Cores, Pairs, Triples and Quads
4th and 5th Characters
Conductor Cross Sectional Areas
B
3
02
1st Character
Type
Voltage
Type
Voltage
F
Fire resistant, reduced halogen
150/250V M
Flame retardant, reduced halogen
G
Fire resistant, LSF
150/250V N
Flame retardant, reduced halogen
1.9/3.3kV
H
Flame retardant, reduced halogen
8.7/15kV P
Flame retardant, reduced halogen
6.35/11kV
J
Flame retardant, reduced halogen
150/250V M
Flame retardant, LSF
600/1000V
K
Flame retardant, LSF
150/250V N
Fire resistant, reduced halogen
600/1000V
L
Flame retardant, reduced halogen
Fire resistant, LSF
600/1000V
600/1000V P
2nd Character
3.8/6.6kV
3rd Character
Basic Construction
Sheath Colour
Armour
A
Flame retardant
Black (600/1000V), Red (HV)
B
Flame retardant
C
Screen
1
Single Core
K
12 pair
Bronze Braid
2
2 Core
L
20 pair
Black (600/1000V), Red (HV)
GSWB
3
3 Core
M
27 pair
Fire resistant
Black (600/1000V)
Bronze Braid
4
4 Core
N
37 pair
D
Fire resistant
Black (600/1000V)
GSWB
7
7 Core
R
1 triple
E
Flame retardant
Green/Yellow
None None
A
12 Core
S
3 triple
F
Flame retardant
Black
None None
B
19 Core
T
7 triple
G
Flame retardant
Light Blue
GSWB
Collective
C
27 Core
U
12 triple
H
Flame retardant
Light Blue
GSWB
Individual
D
37 Core
X
1 quad
J
Flame retardant
Grey
GSWB
Collective
F
1 pair
Y
3 quad
K
Flame retardant
Grey
GSWB
Individual
H
3 pair
Z
7 quad
L
Fire resistant
Light Blue
GSWB
Collective
J
7 pair
M
Fire resistant
Light Blue
GSWB
Individual
N
Fire resistant
Grey
GSWB
Collective
P
Fire resistant
Grey
GSWB
Individual
Y
Flame retardant
Orange
GSWB
Co-axial
4th and 5th Characters 00
0.75 mm2
Flexible (class 5) stranded tinned copper cores
50
50.0 mm2
Stranded tinned copper cores
01
1.0 mm
Flexible (class 5) stranded tinned copper cores
70
70.0 mm2
Stranded tinned copper cores
02
1.5 mm2
Flexible (class 5) stranded tinned copper cores
95
95.0 mm2
Stranded tinned copper cores
03
2.5 mm2
Stranded tinned copper cores
OA
120.0 mm2
Stranded tinned copper cores
04
4.0 mm2
Stranded tinned copper cores
OB
150.0 mm2
Stranded tinned copper cores
05
4.0 mm2
Single solid tinned copper cores (special)
OC
185.0 mm2
Stranded tinned copper cores
06
6.0 mm2
Stranded tinned copper cores
OD
240.0 mm2
Stranded tinned copper cores
10
10.0 mm2
Stranded tinned copper cores
OE
300.0 mm2
Stranded tinned copper cores
16
16.0 mm2
Stranded tinned copper cores
OF
400.0 mm2
Stranded tinned copper cores
25
25.0 mm2
Stranded tinned copper cores
OG
500.0 mm2
Stranded tinned copper cores
35
35.0 mm2
Stranded tinned copper cores
OH
630.0 mm2
Stranded tinned copper cores
2
FPAL Verify
Verified
No.10049350
ABS
IEC Standards and tests
Page 1 of 5
FPAL Verify
Verified
No.10049350
ABS
Page 2 of 5
FPAL Verify
Verified
No.10049350
ABS
Page 3 of 5
These cable types have Mica tape applied around the conductors which is then insulated with a heat-resistant compound and have an outer sheathing of a halogen-free material and have a metal braid armour between the insulation and outer sheathing.
FPAL Verify
Verified
No.10049350
ABS
Page 4 of 5
FPAL Verify
Verified
No.10049350
ABS
Page 5 of 5
Offshore Cables
FPAL Verify
Verified
No.10049350
ABS
Norwegian and International Marine Specification Cables Standards and tests Norwegian Specification offshore topside cables are designed in accordance with the following major IEC-standards and tests Standard
Title of standard
NEK 606:2004
Cables for offshore installations halogen-free and/or mud resistant.
IEC 60092-3
Electrical installations in ships.
IEC 60092-350
Low voltage shipboard power cables. General construction and test requirements.
IEC 60092-351
Insulating materials of shipboard power cables.
IEC 60092-352
Electrical installations in ships choice and installation of cables for low voltage power systems.
IEC 60092-353
Single and multicore non-radial field power cables with extruded solid insulation for rated voltages 1kV and 3kV.
IEC 60092-359
Sheathing materials for shipboard power and telecommunication cables.
IEC 60092-376:2003 Electrical installations in ships – Cables for control instrumentation circuits 150/250V (300V). IEC 60331-31
Tests for electric cables under fire conditions – Circuit integrity procedure and requirements for fire with shock – Cables of rated voltage up to and including 0.6/1kV.
IEC 60332-1
Tests on electric cables under fire conditions. Test on a single vertical insulated wire or cable.
IEC 60332-3-22
Tests on electric cables under fire conditions. Tests for vertical flame spread of vertically-mounted bunched wires of cables – Category A.
IEC 60754-1/2
Test on gases evolved during combustion of electric cables. Part 1: Determination of the halogen acid gas. Part 2: Determination of the degree of acidity during the combustion of materials taken from electric cables by measuring pH and conductivity.
IEC 61034-2
Measurement of smoke density of cables burning under defined conditions.
CSA C22.2 No 39-05
Thermoset Insulated Wires and Cables – Wiring Products. Clause 6.4.4: Low Temperature Flexibility (-40° C) Clause 6.4.5: Low Temperature Impact (-40° C)
FPAL Verify
Verified
No.10049350
ABS
NEK 606 Materials – Abbreviations – Code Designations
1st Letter
Insulation Materials Fire resistant tape + insulation (Halogen-free)
B
Ethylene Propylene rubber – EPR
R
Cross-linked polyethylene XLPE
T
Thermoplastic compound (Halogen-free)
I
Halogen-free thermoset compound EMA or EVA
U
Fibre, tight buffered
A
Fibre in loose tube
Q
2nd Letter
Bedding/ Inner covering Inner sheath
Bedding/Inner covering or taping (Halogen-free)
F
Screen (poss. with PE or PP)
Y
3rd Letter 4th Letter Armour/ screen
Aluminium (laminated to outer jacket)
L
No armour
X
Copper wire braid (Tinned or bare)
O
Strength member of yarn
A
Galvanised steel wire braid
C
Thermoplastic compound (Halogen-free) SHF1
Outer sheath
I
I
Halogen-free thermoset compound, SHF2
U
Halogen-free mud resistant thermoset compound, SHF Mud
U
Halogen-free mud resistant thermoplastic
B1)
1)
QFCB Cables only
FPAL Verify
Verified
No.10049350
ABS
Index
FPAL Verify
Verified No.10049350
ABS
CATALOGUE INDEX British Specification BS6883 / BS7917 SECTION 1 Offshore Instrumentation Cables BS6883 Flame Retardant BS6883 / BS7917 Fire Resistant SECTION 2 Offshore Power & Control Cables BS6883 Flame Retardant BS6883 / BS7917 Fire Resistant SECTION 3 Medium Voltage Power Cables BS6883 Flame Retardant Norwegian Specification NEK 606 SECTION 4 Offshore Instrumentation Cables RFOU Flame Retardant BFOU Fire Resistant SECTION 5 Offshore Power & Control Cables RFOU Flame Retardant BFOU Fire Resistant SECTION 6 Medium Voltage Power Cables RFOU Flame Retardant BFOU Fire Resistant Marine Cables SECTION 7 Instrument Cables Flame Retardant Fire Resistant SECTION 8 Power & Control Cables Flame Retardant Fire Resistant SECTION 9 Offshore Fibre Optic Cables
FPAL Verify
Verified No.10049350
ABS
Section 1 Offshore Instrumentation Cables to BS6883 Specification
FLAME RETARDANT
FPAL Verify
Verified No.10049350
ABS
1
BS6883
Offshore Instrumentation Cables to BS6883 Specification NEK606
150/250V Flame Retardant
Pairs/Triples/Quads Armoured Cables – Collectively Screened:
Applicable Standards
IEEE
BS6883 / IEC 60092-359 BS7655 BS EN 10257-1 IEC 60332 part 3 (Category A, B & C) IEC-60228 Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS6360
This range of cables is designed for use in fixed wiring in ships and offshore units, e.g. safety and emergency lighting, fire pumps, shut down systems, communication systems, gas detectors, and alarms. These cables are ideal for occupied areas including accommodation facilities, control rooms and computer suites.
IEC
Application
Conductor Identification Single Pair: Black and White Multi-Pair: Black and White Numbered Pairs Triples: Black, White and Red Numbered Triples Quads: Black, White, Red and Blue Numbered Quads New harmonised core colours or project specified colours can be supplied upon special request
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to BS6360 Class 2 (Flexible Class 5 conductors available upon request)
(2) Insulation:
EPR Complying with BS7655 GP4
(3) Collective Screen:
Aluminium Mylar Tape Screen in contact with Tinned Copper drain wire Note: A suitable tape or tapes may be applied over the collectively screened pairs, triples, or quads
(4) Bedding:
EVA - SW4 Thermo set Rubber Compound Complying with BS7655 (UKOOA type KG/KJ) OR CSP - SW2 Thermo set Rubber Compound Complying with BS7655 (UKOOA type JG/JJ)
(5) Armour:
Galvanised Steel Wire Braid to BS EN 10257-1 Note: A suitable tape or tapes may be applied under and/or over the braid
(6) Outer Sheath:
EVA - SW4 Thermo set Rubber Compound Complying with BS7655 (UKOOA type KG/KJ) OR CSP - SW2 Thermo set Rubber Compound Complying with BS7655 (UKOOA type JG/JJ)
Datasheet Ref: OFS-BS-INS-CS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250V Flame Retardant
Offshore Instrumentation Cables to BS6883 Specification
Pairs/Triples/Quads Collectively Screened Armoured Cables - Table 1/3 Cable
1x2x0.75
2x2x0.75
3x2x0.75
7x2x0.75
12x2x0.75
20x2x0.75
1x3x0.75 (Ind. Screen)
3x3x0.75
7x3x0.75
Stranding mm
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.2
1.2
1.2
1.4
1.6
1.8
1
1.3
1.5
Diameter over Inner Sheath (min/max) mm
7.6/9.6
11.6/13.6
12.6/14.5
16.6/18.7
21.7/24.2
27.3/30.1
7.9/9.9
14.2/16.2
19.2/21.2
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.3
0.45
0.3
0.3
0.3
Thickness of Outer Sheath mm
1.25
1.4
1.4
1.7
1.7
2
1.25
1.2
1.4
Overall Diameter (min/max) mm
11.9/13.9
17.3/19.3
16.7/19.0
20.9/23.8
26.4/29.5
33.3/37.1
12.5/14.5
19.4/21.4
25.0/27.0
Gland Size
O
A
A
B
C
C2
O
B
C
Weight kg/km
200
385
468
706
1030
1662
285
680
1325
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
Maximum L/R ratio
21
21
21
21
21
21
21
21
21
Maximum LOOP self inductance mH/km
0.86
0.86
0.86
0.86
0.86
0.86
0.86
0.86
0.86
Maximum Mutual Capacitance – pF/m
104
88
88
88
88
88
92
88
88
DC Resistance @ 20°c – OHMS/km
25.3
25.3
25.3
25.3
25.3
25.3
25.3
25.3
25.3
AC Resistance @ 90°c – OHMS/km
32.3
32.3
32.3
32.3
32.3
32.3
32.3
32.3
32.3
Sheath Colour
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
KGH00
KGJ00
KGK00
KGL00
KGR00
KGS00
KGT00
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
KJH00
KJJ00
KJK00
KJL00
KJR00
KJS00
KJT00
KGF00 UKOOA Codes (EVA)
UKOOA Codes (CSP)
(Blue) KJF00
-
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
JGF00
JGH00
JGJ00
JGK00
JGL00
JGR00
JGS00
JGT00
(Blue) JJF00
-
(Grey)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
JJH00
JJJ00
JJK00
JJL00
JJR00
JJS00
JJT00
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
Pairs/Triples/Quads Collectively Screened Armoured Cables - Table 2/3 Cable
12x3x0.75
1x2x1.0 (Ind.Screen)
1x3x1.0 (Ind.Screen)
1x4x1.0 (Ind.Screen)
1x2x1.5
2x2x1.5
3x2x1.5
5x2x1.5
7x2x1.5
Stranding mm
24/0.20
32/0.20
32/0.20
32/0.20
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.7
1
1.1
1.1
1.1
1.2
1.3
1.4
1.4
Diameter over Inner Sheath (min/max) mm
26.1/28.1
8.2/10.2
8.7/10.7
10.0/12.0
8.7/9.8
12.8/14.0
14.4/16.0
17.5/19.1
19.0/23.7 0.3
Diameter of Armour/Braid mm
0.45
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Thickness of Outer Sheath mm
1.7
1
1.1
1.2
1.2
1.4
1.4
1.6
1.6
Overall Diameter (min/max) mm
33.6/35.6
12.4/14.4
13.0/15.0
14.0/16.0
12.7/14.3
16.4/18.0
18.8/20.8
22.2/24.6
23.7/26.2
Gland Size
C2
O
O
O
O
A
B
B
C
Weight kg/km
2106
180
300
180
297
505
593
826
929
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
Maximum L/R ratio
21
27
27
27
38
38
38
38
38
Maximum LOOP self inductance mH/km
0.86
0.819
0.819
0.819
0.778
0.778
0.778
0.778
0.778
Maximum Mutual Capacitance – pF/m
88
115
101
101
128
105
105
105
105
DC Resistance @ 20°c – OHMS/km
25.3
18.6
18.6
18.6
12.4
12.4
12.4
12.4
12.4
AC Resistance @ 90°c – OHMS/km
32.3
23.7
23.7
23.7
15.9
15.9
15.9
15.9
15.9
Sheath Colour
Grey/Blue
Grey/ Blue
Grey/ Blue
Grey/ Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
KGU00
KGF01
KGR01
KGX01
KGF02
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
KJU00
KJF01
KJR01
KJX01
KJF02
UKOOA Codes (EVA)
UKOOA Codes (CSP)
KGH02 -
(Blue) KJH02
KGJ02 -
(Blue) KJJ02
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
JGU00
JGF01
JGR01
JGX01
JGF02
JGH02
JGJ02
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
JJU00
JJF01
JJR01
JJX01
JJF02
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
-
(Blue) JJH02 (Grey)
-
(Blue) JJJ02 (Grey)
Datasheet Ref: OFS-BS-INS-CS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250V Flame Retardant
Offshore Instrumentation Cables to BS6883 Specification
Pairs/Triples/Quads Collectively Screened Armoured Cables - Table 3/3 Cable
10x2x1.5
12x2x1.5
20x2x1.5
1x3x1.5
3x3x1.5
5x3x1.5
7x3x1.5
12x3x1.5
1x2x2.5
Stranding mm
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.7
1.7
1.9
1.1
1.3
1.5
1.5
1.8
1.1
Diameter over Inner Sheath (min/max) mm
24.2/26.4
25.0/27.2
31.5/34.2
9.2/10.3
17.9/19.6
19.0/21.0
24.1/26.3
32.6/35.4
9.8/11.8
Diameter of Armour/Braid mm
0.3
0.45
0.45
0.3
0.3
0.3
0.3
0.45
0.3
Thickness of Outer Sheath mm
1.9
1.9
2.1
1.2
1.5
1.6
1.7
2
1.2
Overall Diameter (min/max) mm
29.5/32.6
31.0//34.2
38.1/41.7
13.2/14.8
22.4/24.9
25.0/27.0
29.0/32.0
38.9/42.5
14.1/16.1
Gland Size
C
C2
D
O
B
C
C
D
A
Weight kg/km
1343
1510
2287
304
760
928
1262
2148
320
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
Maximum L/R ratio
38
38
38
38
38
38
38
38
58
Maximum LOOP self inductance mH/km
0.778
0.778
0.778
0.778
0.778
0.778
0.778
0.778
0.731
Maximum Mutual Capacitance – pF/m
105
105
105
111
105
105
105
105
148
DC Resistance @ 20°c – OHMS/km
12.4
12.4
12.4
12.4
12.4
12.4
12.4
12.4
7.71
AC Resistance @ 90°c – OHMS/km
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
9.83
Sheath Colour
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
KGK02
KGL02
KGR02
KGS02
KGT02
KGU02
KGF03
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
KJK02
KJL02
KJR02
KJS02
KJT02
KJU02
KJF03
UKOOA Codes (EVA)
UKOOA Codes (CSP)
-
-
-
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
JGK02
JGL02
JGR02
JGS02
JGT02
JGU02
JGF03
(Blue)
(Blue)
(Blue)
(Blue)
JJK02
JJL02
JJR02
JJS02
(Grey)
(Grey
(Grey)
(Grey)
-
(Blue)
(Blue)
(Blue)
JJT02
JJU02
JJF03
(Grey)
(Grey)
(Grey)
Datasheet Ref: OFS-BS-INS-CS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883
Offshore Instrumentation Cables to BS6883 Specification NEK606
150/250V Flame Retardant
Pairs/Triples/Quads Armoured Cables – Individually Screened:
Applicable Standards
IEEE
BS6883 / IEC 60092-359 BS7655 IEC 60332 part 3 (Category A, B & C) IEC-60228 Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS6360
Application IEC
This range of cables is designed for use in fixed wiring in ships and offshore units, e.g. safety and emergency lighting, fire pumps, shut down systems, communication systems, gas detectors, and alarms. These cables are ideal for occupied areas including accommodation facilities, control rooms and
Conductor Identification Single Pair: Black and White Multi-Pair: Black and White Numbered Pairs Triples: Black, White and Red Numbered Triples Quads: Black, White, Red and Blue Numbered Quads New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to BS6360 Class 2 (Flexible Class 5 conductors available upon request)
(2) Insulation:
EPR Complying with BS7655 GP4
(3) Individual Screen:
Aluminium Mylar Tape Screen in contact with Tinned Copper drain wire Note: A suitable tape or tapes may be applied over the collectively screened pairs, triples, or quads
(4) Bedding:
EVA - SW4 Thermo set Rubber Compound Complying with BS7655 (UKOOA type KG/KJ) OR CSP - SW2 Thermo set Rubber Compound Complying with BS7655 (UKOOA type JG/JJ)
(5) Armour:
Galvanised Steel Wire Braid to BS EN 10257-1 Note: A suitable tape or tapes may be applied under and/or over the braid
(6) Outer Sheath:
EVA - SW4 Thermo set Rubber Compound Complying with BS7655 (UKOOA type KG/KJ) OR CSP - SW2 Thermo set Rubber Compound Complying with BS7655 (UKOOA type JG/JJ)
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
Datasheet Ref: OFS-BS-INS-IS-FR
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250V Flame Retardant
Offshore Instrumentation Cables to BS6883 Specification
Pairs/Triples/Quads Individually Screened Armoured Cables - Table 1/3 Cable
1x2x0.75
2x2x0.75
3x2x0.75
7x2x0.75
12x2x0.75
20x2x0.75
1x3x0.75
3x3x0.75
7x3x0.75 24/0.20
Stranding mm
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
7/0.53
24/0.20
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.2
1.2
1.2
1.4
1.6
1.8
1
1.3
1.5
Diameter over Inner Sheath (min/max) mm
7.6/9.6
8.6/10.4
12.6/14.5
16.9/19.0
21.3/23.7
27.8/30.7
7.9/9.9
14.2/16.2
19.7/22.1
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.3
0.45
0.3
0.3
0.3
Thickness of Outer Sheath mm
1.25
1.4
1.4
1.6
1.8
2
2
1.5
1.7
Overall Diameter (min/max) mm
11.9/13.9
12.4/14.3
16.7/19.0
21.4/24.3
26.1/29.2
33.8/37.8
12.5/14.5
18.6/20.9
24.4/27.4
Gland Size
O
O
A
B
C
C2
O
B
C
Weight kg/km
200
287
549
919
1380
1680
285
699
1172
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
Maximum L/R ratio
21
21
21
21
21
21
21
21
21
Maximum LOOP self inductance mH/km
0.86
0.86
0.86
0.86
0.86
0.86
0.86
0.86
0.86
Maximum Mutual Capacitance – pF/m
104
104
104
104
104
104
92
92
92
DC Resistance @ 20°c – OHMS/km
25.3
25.3
25.3
25.3
25.3
25.3
25.3
25.3
25.3
AC Resistance @ 90°c – OHMS/km
32.3
32.3
32.3
32.3
32.3
32.3
32.3
32.3
32.3
Sheath Colour
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
KHH00
KHJ00
KHK00
KHL00
KHR00
KHS00
KHT00
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
KKH00
KKJ00
KKK00
KKL00
KKR00
KKS00
KKT00
KHF00 UKOOA Codes (EVA)
UKOOA Codes (CSP)
(Blue) KKF00
-
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
JHF00
JHH00
JHJ00
JHK00
JHL00
JHR00
JHS00
JHT00
(Blue) JKF00
-
(Grey)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
JKH00
JKJ00
JKK00
JKL00
JKR00
JKS00
JKT00
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
Pairs/Triples/Quads Individually Screened Armoured Cables - Table 2/3 Cable
12x3x0.75
1x2x1.0
1x3x1.0
1x4x1.0
1x2x1.5
2x2x1.5
3x2x1.5
5x2x1.5
7x2x1.5 7/0.53
Stranding mm
24/0.20
32/0.20
32/0.20
32/0.20
7/0.53
7/0.53
7/0.53
7/0.53
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.7
1
1.1
1.1
1.1
1.1
1.3
1.4
1.5
Diameter over Inner Sheath (min/max) mm
24.4/27.1
8.2/10.2
8.7/10.7
9.0/11.0
8.9/9.9
14.6/16.1
15.2/16.8
18.8/20.5
20.9/23.0
Diameter of Armour/Braid mm
0.45
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Thickness of Outer Sheath mm
2
1
1.1
1.2
1.2
1.2
1.5
1.6
1.7
Overall Diameter (min/max) mm
30.4/34.1
12.4/14.4
13.0/15.0
14.0/16.0
13.1/15.1
19.0/21.1
19.7/22.1
23.5/26.0
25.9/28.5
Gland Size
C2
O
O
O
O
B
B
B
C
Weight kg/km
1982
262
273
300
260
591
697
983
1181
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
Maximum L/R ratio
21
27
27
27
38
38
38
38
38
Maximum LOOP self inductance mH/km
0.86
0.819
0.819
0.819
0.778
0.778
0.778
0.778
0.778
Maximum Mutual Capacitance – pF/m
92
115
101
101
128
128
128
128
128
DC Resistance @ 20°c – OHMS/km
25.3
18.6
18.6
18.6
12.4
12.4
12.4
12.4
12.4
AC Resistance @ 90°c – OHMS/km
32.3
23.7
23.7
23.7
15.9
15.9
15.9
15.9
15.9
Sheath Colour
Grey/Blue
Grey/ Blue
Grey/ Blue
Grey/ Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
KHU00
KHF01
KHR01
KHX01
KHF02
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
KKU00
KKF01
KKR01
KKX01
KKF02
UKOOA Codes (EVA)
UKOOA Codes (CSP)
KHH02 -
(Blue) KKH02
KHJ02 (Blue)
-
KKJ02
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
JHU00
JHF01
JHR01
JHX01
JHF02
JHH02
JHJ02
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
JKU00
JKF01
JKR01
JKX01
JKF02
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
-
(Blue) JKH02
(Blue)
-
JKJ02
(Grey)
(Grey)
Datasheet Ref: OFS-BS-INS-IS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250V Flame Retardant
Offshore Instrumentation Cables to BS6883 Specification
Pairs/Triples/Quads Individually Screened Armoured Cables - Table 3/3 Cable
10x2x1.5
12x2x1.5
20x2x1.5
1x3x1.5
3x3x1.5
5x3x1.5
7x3x1.5
12x3x1.5
1x2x2.5
Stranding mm
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.7
1.8
2
1.1
1.4
1.5
1.6
1.9
1.1
Diameter over Inner Sheath (min/max) mm
25.6/27.8
27.2/29.4
36.2/39.0
9.4/11.4
16.4/18.4
20.2/22.2
22.3/24.3
30.6/32.6
9.8/11.8
Diameter of Armour/Braid mm
0.45
0.45
0.45
0.3
0.3
0.3
0.3
0.45
0.3
Thickness of Outer Sheath mm
2
2
2.3
1.2
1.5
1.7
1.8
2.1
1.2
Overall Diameter (min/max) mm
31.8/35.0
33.4/36.5
42.9/46.8
13.8/15.8
21.8/23.8
25.9/27.9
28.2/30.2
38.1/40.1
14.1/16.1
Gland Size
C2
C2
D
O
B
C
C
C2
A
Weight kg/km
1323
1907
2250
331
780
1100
1409
2301
320
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
Maximum L/R ratio
38
38
38
38
38
38
38
38
58
Maximum LOOP self inductance mH/km
0.778
0.778
0.778
0.778
0.778
0.778
0.778
0.778
0.731
Maximum Mutual Capacitance – pF/m
128
128
128
111
111
111
111
111
148
DC Resistance @ 20°c – OHMS/km
12.4
12.4
12.4
12.4
12.4
12.4
12.4
12.4
7.71
AC Resistance @ 90°c – OHMS/km
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
9.83
Sheath Colour
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
KHK02
KHL02
KHR02
KHS02
KHT02
KHU02
KHF03
UKOOA Codes (EVA)
-
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
KKK02
KKL02
KKR02
KKS02
KKT02
KKU02
KKF03
UKOOA Codes (CSP)
-
-
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
JHK02
JHL02
JHR02
JHS02
JHT02
JHU02
JHF03
(Blue)
(Blue)
(Blue)
(Blue)
JKK02
JKL02
JKR02
JKS02
(Grey)
(Grey
(Grey)
(Grey)
-
(Blue)
(Blue)
(Blue)
JKT02
JKU02
JKF03
(Grey)
(Grey)
(Grey)
Datasheet Ref: OFS-BS-INS-IS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
Section 1 Offshore Instrumentation Cables to BS6883/BS7917 Specification
FIRE RESISTANT
FPAL Verify
Verified No.10049350
ABS
1
BS6883
Offshore Instrumentation Cables to BS6883 Specification
Pairs/Triples/Quads Armoured Cables – Collectively Screened:
NEK606
150/250 V Fire Resistant
Applicable Standards
IEEE
BS6883 / BS7917 / IEC 60092-359 BS7655 IEC 60331 part 3 (Category A, B &C) IEC-60228 Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS6360
This range of cables is designed for use in fixed wiring in ships and offshore units, e.g. safety and emergency lighting, fire pumps, shut down systems, communication systems, gas detectors, and alarms. These cables are ideal for occupied areas including accommodation facilities, control rooms and computer suites.
IEC
Application
Conductor Identification Single Pair: Black and White Multi-Pair: Black and White Numbered Pairs Triples: Black, White and Red Numbered Triples Quads: Black, White, Red and Blue Numbered Quads New harmonised core colours or project specified colours can be supplied upon special request
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to BS6360 Class 2 (Flexible Class 5 conductors available upon request)
(2) Fire Protection:
Mica Glass Tape
(3) Insulation:
EPR Complying with BS7655 GP4
(4) Collective Screen:
Aluminium Mylar Tape Screen in contact with Tinned Copper drain wire Note: A suitable tape or tapes may be applied over the collectively screened pairs, triples, or quads
(5) Bedding:
EVA - SW4 Thermo set Rubber Compound Complying with BS7655 (UKOOA type GL/GN) OR CSP - SW2 Thermo set Rubber Compound Complying with BS7655 (UKOOA type FL/FN)
(6) Armour:
Galvanised Steel Wire Braid to BS EN 10257-1 Note: A suitable tape or tapes may be applied under and/or over the braid
(7) Outer Sheath:
EVA - SW4 Thermo set Rubber Compound Complying with BS7655 (UKOOA type GL/GN) OR CSP - SW2 Thermo set Rubber Compound Complying with BS7655 (UKOOA type FL/FN)
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
Datasheet Ref: OFS-BS-INS-CS-FS www.interkab.com
FPAL Verify
Verified
No.10049350
ABS
150/250 V Fire Resistant
Offshore Instrumentation Cables to BS6883 Specification
Pairs/Triples/Quads Collectively Screened Armoured Cables - Table 1/2 Cable
2x2x0.75
3x2x0.75
7x2x0.75
12x2x0.75
20x2x0.75
3x3x0.75
7x3x0.75
12x3x0.75
1x2x1.0 1x3x1.0 1x4x1.0 (Ind.Screen) (Ind.Screen) (Ind.Screen)
Stranding mm
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.2
1.2
1.4
1.6
1.8
1.3
1.5
1.8
1
1
1.1
Diameter over Inner Sheath (min/max) mm
11.9/13.9
12.2/14.9
16.1/18.9
20.8/24.4
27.7/31.3
14.8/16.8
19.7/21.7
27.1/29.1
8.8/10.8
9.0/11.0
10.3/12.3
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.45
0.3
0.3
0.45
0.3
0.3
0.3
Diameter over Armour/Braid mm
14.5
14.8
18.7
24
31.5
16.8
21.7
29.4
-
-
-
Thickness of Outer Sheath mm
1.2
1.4
1.5
1.7
2
1.5
1.7
2
1
1
1.2
Overall Diameter (min/max) mm
16.1/18.1
16.4/19.2
20.2/23.8
25.9/29.3
33.2/37.4
18.8/21.2
23.8/26.8
31.6/35.6
13.0/15.0
13.3/15.3
14.3/16.3
Gland Size
A
A
B
C
C2
B
C
C2
O
O
A
Weight kg/km
390
520
780
1150
1900
520
870
1500
180
300
430
32/0.20
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85 100
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
Inductance/ Resistance – mH/W
<25
<25
<25
<25
<25
<25
<25
<25
<25
<25
<25
Capacitance – nF/KM
<110
<90
<90
<90
<90
<90
<90
<90
<140
<110
<110
DC Resistance @ 20°c – OHMS/km
25.3
26.7
26.7
26.7
26.7
26.7
26.7
26.7
18.6
18.6
18.6
DC Resistance @ 85°c – OHMS/km
32.3
33.5
33.5
33.5
33.5
33.5
33.5
33.5
23.7
23.7
23.7
Sheath Colour
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/ Blue
Grey/ Blue
Grey/ Blue
GLH00
GLJ00
GLK00
GLL00
GLS00
GLT00
GLU00
GLF01
GLR01
GLX01
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
GNH00
GNJ00
GNK00
GNL00
GNS00
GNT00
GNU00
GNF01
GNR01
GNX01
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
FLH00
FLJ00
FLK00
FLL00
FLS00
FLT00
FLU00
FLF01
FLR01
FLX01
UKOOA Codes (EVA)
-
UKOOA Codes (CSP)
-
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
FNH00
FNJ00
FNK00
FNL00
FNS00
FNT00
FNU00
FNF01
FNR01
FNX01
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
Pairs/Triples/Quads Collectively Screened Armoured Cables - Table 2/2 Cable
1x2x1.5
2x2x1.5
3x2x1.5
5x2x1.5
7x2x1.5
10x2x1.5
12x2x1.5
24x2x1.5
3x3x1.5
5x3x1.5
7x3x1.5
12x3x1.5
Stranding mm
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.2
1.2
1.3
1.4
1.4
1.7
1.7
2
1.3
1.5
1.5
1.8
Diameter over Inner Sheath (min/max) mm
9.6/10.8
14.3/15.5
15.8/17.4
19.3/21.1
21.0/23.0
26.8/29.0
27.7/29.9
39.0/42.0
19.8/21.8
20.7/22.7
26.7/28.8
36.2/39.0
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.3
0.3
0.45
0.45
0.3
0.3
0.3
0.3
Thickness of Outer Sheath mm
1.3
1.4
1.4
1.6
1.6
1.9
1.9
2.2
1.3
1.5
1.5
1.8
Overall Diameter (min/max) mm
13.6/15.2
18.4/20.0
20.1/26.6
24.0/30.5
25.7/32.6
32.0/39.2
33.7/40.8
45.8/49.7
24.3/31.0
26.5/28.5
31.5/38.7
42.4/50.1
Gland Size
O
A
C
C
C
C2
C2
D
C
C
C2
D
Weight kg/km
320
600
771
1045
1189
1678
1869
3225
979
1287
1594
2647
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
Inductance/ Resistance – mH/W
0.68
0.68
0.68
0.68
0.68
0.68
0.68
0.68
0.68
0.68
0.68
0.68
Capacitance – nF/KM
<110
<110
<110
<110
<110
<110
<110
<110
<110
<110
<110
<110
DC Resistance @ 20°c – OHMS/km
12.4
12.4
12.4
12.4
12.4
12.4
12.4
12.4
12.4
12.4
12.4
12.4
DC Resistance @ 85°c – OHMS/km
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
Sheath Colour
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
GLT02
GLU02
GLF02 UKOOA Codes (EVA)
UKOOA Codes (CSP)
(Blue) GNF02
GLH02 -
(Blue) GNH02
GLJ02 -
(Blue) GNJ02
GLK02 -
(Blue) GNK02
GLS02 -
(Blue) GNS02
-
(Blue)
(Blue)
GNT02
GNU02
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
FLF02
FLH02
FLJ02
FLK02
FLS02
FLT02
FLU02
(Blue) FNF02 (Grey)
-
(Blue) FNH02 (Grey)
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
-
(Blue) FNJ02 (Grey)
-
(Blue) FNK02 (Grey)
-
(Blue) FNS02 (Grey)
-
(Blue)
(Blue)
FNT02
FNU02
(Grey)
(Grey)
Datasheet Ref: OFS-BS-INS-CS-FS
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883
Offshore Instrumentation Cables to BS6883 Specification
Pairs/Triples/Quads Armoured Cables â&#x20AC;&#x201C; Individually Screened:
NEK606
150/250 V Fire Resistant
Applicable Standards
IEEE
BS 6883 / BS7917 / IEC 60092-359 BS7655 IEC 60331 part 3 (Category A, B &C) IEC-60228 Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS6360
Application IEC
This range of cables is designed for use in fixed wiring in ships and offshore units, e.g. safety and emergency lighting, fire pumps, shut down systems, communication systems, gas detectors, and alarms. These cables are ideal for occupied areas including accommodation facilities, control rooms and computer suites.
Conductor Identification Single Pair: Black and White Multi-Pair: Black and White Numbered Pairs Triples: Black, White and Red Numbered Triples Quads: Black, White, Red and Blue Numbered Quads New harmonised core colours or project specified colours can be supplied upon special request
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to BS6360 Class 2 (Flexible Class 5 conductors available upon request)
(2) Fire Protection:
Mica Glass Tape
(3) Insulation:
EPR Complying with BS7655 GP4
(4) Individual Screen:
Aluminium Mylar Tape Screen in contact with Tinned Copper drain wire Note: A suitable tape or tapes may be applied over the collectively screened pairs, triples, or quads
(5) Bedding:
EVA - SW4 Thermo set Rubber Compound Complying with BS7655 (UKOOA type GM/GP) OR CSP - SW2 Thermo set Rubber Compound Complying with BS7655 (UKOOA type FM/FP)
(6) Armour:
Galvanised Steel Wire Braid to BS EN 10257-1 Note: A suitable tape or tapes may be applied under and/or over the braid
(7) Outer Sheath:
EVA - SW4 Thermo set Rubber Compound Complying with BS7655 (UKOOA type GM/GP) OR CSP - SW2 Thermo set Rubber Compound Complying with BS7655 (UKOOA type FM/FP)
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
Datasheet Ref: OFS-BS-INS-IS-FS www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250 V Fire Resistant
Offshore Instrumentation Cables to BS6883 Specification
Pairs/Triples/Quads Individually Screened Armoured Cables - Table 1/2 Cable
2x2x0.75
3x2x0.75
7x2x0.75
12x2x0.75
20x2x0.75
3x3x0.75
7x3x0.75
12x3x0.75
1x4x0.75
1x2x1.0
1x3x1.0
1x4x1.0
Stranding mm
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.2
1.2
1.4
1.6
2.1
1.3
1.5
1.9
1.2
1
1
1
Diameter over Inner Sheath (min/max) mm
9.1/10.9
12.8/15.6
16.9/19.9
22.0/25.8
33.2/35.2
14.8/17.2
19.9/23.3
30.7/32.7
9.3/11.3
8.1/9.9
8.7/10.7
10.5/12.5
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.45
0.3
0.3
0.45
0.3
0.3
0.3
0.3
Diameter over Armour/Braid mm
14.5
15.5
19.7
25.8
35.5
17.2
22.9
33.9
11.6
10.3
11
13.1
Thickness of Outer Sheath mm
1.4
1.4
1.6
1.8
2.7
1.5
1.7
2.2
1.3
1.2
1.2
1.3
Overall Diameter (min/max) mm
12.8/14.8
17.1/20.1
21.3/25.1
27.9/31.5
38.1/42.1
18.8/22.0
25.0/28.2
36.5/40.5
13.1/16.0
11.7/14.3
12.2/15.0
14.9/16.9
Gland Size
O
A
B
C
D
B
C
C2
O
O
O
A
Weight kg/km
305
580
915
1420
2905
700
1180
2550
360
295
330
380
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85 100
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
Inductance/ Resistance – mH/W
<25
<25
<25
<25
<25
<25
<25
<25
<25
<25
<25
<25
Capacitance – nF/KM
<110
<110
<110
<110
<110
<110
<110
<110
<140
<140
<110
<110
DC Resistance @ 20°c – OHMS/KM
25.3
26.7
26.7
26.7
26.7
26.7
26.7
26.7
20
20
26.7
26.7
DC Resistance @ 85°c – OHMS/KM
32.3
33.5
33.5
33.5
33.5
33.5
33.5
33.5
25.1
25.1
33.5
33.5
Sheath Colour
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/ Blue
Grey/ Blue
Grey/ Blue
GMH00
GMJ00
GMK00
GML00
GMS00
GMT00
GMU00
GMX00
GMF01
GMR01
GMX01
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
GPH00
GPJ00
GPK00
GPL00
GPS00
GPT00
GPU00
GPX00
GPF01
GPR01
GPX01
UKOOA Codes (EVA)
UKOOA Codes (CSP)
-
-
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
FMH00
FMJ00
FMK00
FML00
FMS00
FMT00
FMU00
FMX00
FMF01
FMR01
FMX01
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
(Blue)
FPH00
FPJ00
FPK00
FPL00
FPS00
FPT00
FPU00
FPX00
FPF01
FPR01
FPX01
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
Pairs/Triples/Quads Individually Screened Armoured Cables - Table 2/2 Cable
2x2x1.5
3x2x1.5
5x2x1.5
7x2x1.5
10x2x1.5
12x2x1.5
21x2x1.5
24x2x1.5
3x3x1.5
5x3x1.5
7x3x1.5
12x3x1.5
Stranding mm
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.2
1.3
1.4
1.4
1.7
1.7
2
2
1.3
1.5
1.5
1.8
Diameter over Inner Sheath (min/max) mm
14.9/16.5
15.9/17.5
19.5/21.4
21.5/23.6
27.4/29.6
28.6/30.8
42.4/44.4
47.4/49.4
18.1/20.1
22.5/24.5
25.2/27.2
35.3/37.3
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.3
0.45
0.45
0.45
0.3
0.3
0.3
0.45
Thickness of Outer Sheath mm
1.4
1.4
1.6
1.6
1.9
1.9
2.1
2.1
1.5
1.6
1.7
2
Overall Diameter (min/max) mm
19.3/21.5
20.4/22.8
24.2/26.7
26.5/29.1
33.6/36.7
34.8/37.9
50.6/52.6
55.8/57.8
23.5/25.5
28.0/30.0
31.1/33.1
42.9/44.9
Gland Size
B
B
C
C
C2
C2
D
E
B
C
C2
D
Weight kg/km
602
732
1031
1242
1877
2039
2300
2600
780
1100
1409
2301
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
Inductance/ Resistance – mH/W
0.68
0.68
0.68
0.68
0.68
0.68
0.68
0.68
0.68
0.68
0.68
0.68
Capacitance – nF/KM
<110
<110
<110
<110
<110
<110
<110
<110
<110
<110
<110
<110
DC Resistance @ 20°c – OHMS/km
12.4
12.4
12.4
12.4
12.4
12.4
12.4
12.4
12.4
12.4
12.4
12.4
DC Resistance @ 85°c – OHMS/km
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
Sheath Colour
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
GMT02
GMU02
GMH02 UKOOA Codes (EVA)
UKOOA Codes (CSP)
-
-
(Blue) GPH02
GMJ02 -
(Blue) GPJ02
GMK02 -
(Blue) GPK02
GMS02 -
-
(Blue) GPS02
-
(Blue)
(Blue)
GPT02
GPU02
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
(Grey)
FMH02
FMJ02
FMK02
FMS02
FMT02
FMU02
(Blue) FPH02
-
(Grey)
(Blue) FPJ02 (Grey)
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
-
(Blue) FPK02 (Grey)
-
-
(Blue) FPS02 (Grey)
-
(Blue)
(Blue)
FPT02
FPU02
(Grey)
(Grey)
Datasheet Ref: OFS-BS-INS-IS-FS www.interkab.com FPAL Verify
Verified
No.10049350
ABS
Section 2 Offshore Power & Control Cables to BS6883 Specification
FLAME RETARDANT
FPAL Verify
Verified No.10049350
ABS
2
BS6883 600/1000V Flame Retardant BS6883 - Power Cables Single core armoured:
NEK606
Offshore Power Cables to BS6883 Specification
Applicable Standards
IEEE
BS6883 / IEC 60092-3 BS7655 BS EN 12166 IEC 60332 part 3 (Category A) IEC-60228 Stranded class 2 or tinned annealed copper conductors to BS6360
Application IEC
This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.
Conductor Identification 1 Core – Black New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to BS6360
(2) Insulation:
EPR Complying with BS7655 GP5
(3) Bedding:
EVA – SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance LSZH (UKOOA type WA) OR CSP – SW2 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance (UKOOA type LA)
(4) Armour:
Tinned Phosphor Bronze Wire Braid to BS2873-PB102 (now BS EN 12166)
(5) Outer Sheath:
EVA – SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance and LSZH (UKOOA type WA) OR CSP – SW2 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance (UKOOA type LA)
Datasheet Ref: OFS-BS-PC-SC-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000V Flame Retardant
Offshore Power Cables to BS6883 Specification
Singlecore Armoured Power/Control Cables - Table 1/2 Cable
1x1.0
1x1.5
1x2.5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
Stranding mm
7/0.44
7/0.53
7/0.67
7/0.85
7/1.0
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78 1.4
Insulation Thickness mm
0.8
0.8
0.8
1
1
1
1
1.2
1.2
Thickness of Inner Sheath mm
-
-
-
-
-
-
1.1
1.1
1.1
1.1
Diameter over Inner Sheath (min/max) mm
4.6/6.6
4.9/6.9
5.3/7.3
6.3/8.3
6.8/8.8
7.8/9.8
9.0/11.0
11.4/13.4
12.3/14.3
14.1/16.1 0.3
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Thickness of Outer Sheath mm
-
-
-
-
-
-
1.2
1.2
1.3
1.4
Overall Diameter (min/max) mm
8.5/10.5
8.8/10.8
9.2/11.2
10.3/12.3
10.8/12.8
12.0/14.0
13.2/15.2
15.8/17.8
16.9/18.9
18.7/20.7
Gland Size
Os
Os
Os
O
O
O
O
A
A
B
Weight kg/km
150
170
190
260
340
390
480
565
740
940
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
Inductance– mH/km
-
-
-
-
0.464
0.433
0.405
0.379
0.368
0.357
Capacitance – μF/km
-
-
-
-
0.522
0.379
0.447
0.464
0.514
0.522
DC Resistance @ 20°c – Ώ/km
-
-
-
-
3.11
1.84
1.16
0.734
0.529
0.391
DC Resistance @ 90°c – Ώ/km
-
-
-
-
3.965
2.346
1.479
0.936
0.674
0.499
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
UKOOA Codes (EVA)
WA101
WA102
WA103
WA104
WA106
WA110
WA116
WA125
WA130
WA150
UKOOA Codes (CSP)
LA101
LA102
LA103
LA104
LA106
LA110
LA116
LA125
LA130
LA150
Singlecore Armoured Power/Control Cables - Table 2/2 Cable
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630
Stranding mm
19/2.14
37/1.78
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
91/2.36
91/2.65
127/2.52
Insulation Thickness mm
1.4
1.6
1.6
1.8
2
2.2
2.4
2.6
2.8
2.8
Thickness of Inner Sheath mm
1
1.2
1.4
1.6
1.8
1.3
1.5
1.7
1.2
1
Diameter over Inner Sheath (min/max) mm
16.0/18.0
18.4/20.4
20.4/22.4
22.6/24.6
25.0/27.0
28.3/30.3
31.5/33.5
35.4/37.4
39.4/41.4
43.3/45.3
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.45
0.45
0.45
0.45
0.45
0.45
Diameter over Armour/Braid mm
-
14
17.7
23.1
31.4
15.5
20.4
28.9
11
9.8
Thickness of Outer Sheath mm
1.4
1.4
1.6
1.8
2.1
1.5
1.7
2
1.3
1.2
Overall Diameter (min/max) mm
20.9/22.9
23.5/25.5
25.6/27.6
28.0/30.0
31.6/33.6
35.0/37.0
38.2/40.2
42.7/44.7
47.1/49.1
51.3/53.3
Gland Size
B
B
C
C
C2
C2
C2
D
D
E
Weight kg/km
1270
1500
1750
2200
2700
3400
4200
5700
7200
8840
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
Inductance- mH/km
0.341
0.33
0.321
0.318
0.319
0.31
0.306
0.301
0.296
0.289
Capacitance – μF/km
0.609
0.628
0.694
0.694
0.705
0.727
0.75
0.793
0.821
0.904
DC Resistance @ 20°c – Ώ/km
0.27
0.195
0.154
0.126
0.1
0.0762
0.0607
0.0475
0.0369
0.0286
DC Resistance @ 90°c – Ώ/km
0.344
0.271
0.214
0.175
0.14
0.108
0.087
0.069
0.058
0.045
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
UKOOA Codes (EVA)
WA170
WA195
WA10A
WA10B
WA10C
WA10D
WA10E
WA10F
WA10G
WA10H
UKOOA Codes (CSP)
LA170
LA195
LA10A
LA10B
LA10C
LA10D
LA10E
LA10F
LA10G
LA10H
Datasheet Ref: OFS-BS-PC-SC-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 600/1000V Flame Retardant BS6883 - Power Cables Multi core armoured:
NEK606
Offshore Power Cables to BS6883 Specification
Applicable Standards
IEEE
BS6883 / IEC 60092-3 BS7655 BS EN 10257-1 IEC 60332 part 3 (Category A) IEC-60228 Stranded class 2 or tinned annealed copper conductors to BS6360
Application IEC
This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.
Conductor Identification 1 2 3 4 5
Core Core Core Core Core
– White – White and Numbered (Red, Black on Request) – White and Numbered (Red, Yellow, Blue on Request) – White and numbered (Red, Yellow, Blue, Black on Request) & Above – White and Numbered
New harmonised core colours or project specified colours can be supplied upon special request
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to BS6360
(2) Insulation:
EPR Complying with BS7655 GP5
(3) Bedding:
EVA – SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance and LSZH (UKOOA type WB) CSP – SW2 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance (UKOOA type LB)
(4) Armour:
Galvanised Steel Wire Braid to BS EN 10257-1
(5) Outer Sheath:
EVA – SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance and LSZH (UKOOA type WB) CSP – SW2 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance (UKOOA type LB)
Datasheet Ref: OFS-BS-PC-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000V Flame Retardant
Offshore Power Cables to BS6883 Specification
Multicore Armoured Power/Control Cables - Table 1/5 Cable
2 x1.5
2 x 2.5
2x4
2x6
2 x10
2 x 16
2 x 25
2 x 35
2 x 50
2 x 70
2 x 95
2 x 120
2x150
2 x 185
Stranding mm
7/0.53
7/0.67
7/0.85
7/1.00
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
37/1.78
37/2.03
37/2.25
37/2.52
Insulation Thickness mm
0.8
0.8
1
1
1
1
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2
Thickness of Inner Sheath mm
1.1
1.1
1.2
1.2
-
1.4
-
1.6
-
-
-
-
-
-
Diameter over Inner Sheath (min/max) mm
8.7/10.7
9.6/11.6
11.7/13.7
12.8/14.8
14.9/16.9
17.2/19.2
21.7/23.7
23.7/25.7
27.2/29.2
31.3/33.3
36.0/38.0
39.8/41.8
44.0/46.0
49.0/51.0 0.45
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.45
0.45
0.45
0.45
0.45
Thickness of Outer Sheath mm
1.2
1.2
1.3
1.4
-
1.5
-
1.8
-
-
-
-
-
-
Overall Diameter (min/max) mm
12.9/14.9
13.7/15.7
16.1/18.1
17.3/19.3
19.7/21.7
22.2/24.2
26.9/28.9
29.1/31.1
33.9/35.9
38.2/40.2
43.5/45.5
47.6/49.6
52.1/54.1
57.2/59.2
Gland Size
O
O
A
A
B
B
C
C
C2
C2
D
D
E
E
Weight kg/km
270
310
430
520
680
850
1500
1810
2510
3230
4220
5125
6210
7500
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
100
100
100
Inductance/– mH/km
0.353
0.33
0.329
0.311
0.292
0.277
0.267
0.259
0.258
0.25
0.245
0.241
0.24
0.241 0.374
Capacitance – μF/KM
0.133
0.153
0.158
0.181
0.213
0.248
0.26
0.282
0.288
0.325
0.333
0.366
0.369
DC Resistance max @ 20°c - Ώ/km
12.2
7.56
4.7
3.11
1.84
1.16
0.734
0.529
0.391
0.27
0.195
0.154
0.126
0.1
DC Resistance max @ 90°c - Ώ/km
15.555
9.639
5.993
3.965
2.346
1.479
0.936
0.674
0.499
0.344
0.271
0.214
0.175
0.14
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
UKOOA Code (EVA)
WB202
WB203
WB204
WB206
WB210
WB216
WB225
WB235
WB250
WB270
WB295
WB20A
WB20B
WB20C
UKOOA Code (CSP)
LB202
LB203
LB204
LB206
LB210
LB216
LB225
LB235
LB250
LB270
LB295
LB20A
LB20B
LB20C
Multicore Armoured Power/Control Cables - Table 2/5 Cable
2 x 240
2 x 300
3 x 1.5
3 x 2.5
3x4
3x6
3 x 10
3 x 16
3 x 25
3 x 35
3 x 50
3 x 70
3 x 95
3x120
Stranding mm
61/2.25
61/2.52
7/0.53
7/0.67
7/0.85
7/1.00
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
37/1.78
37/2.03
Insulation Thickness mm
2.2
2.4
0.8
0.8
1
1
1
1
1.2
1.2
1.4
1.4
1.6
1.6
Thickness of Inner Sheath mm
-
-
1.1
1.1
1.2
1.2
1.3
1.4
1.6
1.7
1.8
2
2.2
-
Diameter over Inner Sheath (min/max) mm
55.7/57.7
62.0/64.0
9.3/11.3
10.2/12.2
12.4/14.4
13.7/15.7
15.9/17.9
18.4/20.4
23.4/25.4
25.5/27.5
29.4/31.4
33.7/35.7
38.8/40.8
42.9/44.9 0.45
Diameter of Armour/Braid mm
0.45
0.45
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.45
0.45
0.45
0.45
Thickness of Outer Sheath mm
-
-
1.2
1.3
1.3
1.4
1.5
1.6
1.8
1.9
2
2.2
2.4
-
Overall Diameter (min/max) mm
64.9/66.9
71.5/73.5
13.4/15.4
14.6/16.6
16.8/18.8
18.3/20.3
20.9/22.9
23.5/25.5
28.8/30.8
32.1/34.1
36.0/38.0
40.9/42.9
46.4/48.4
51.0/53.0
Gland Size
F
F
O
A
A
A
B
B
C
C2
C2
D
D
E
Weight kg/km
9440
11500
290
390
520
620
850
1150
1600
2200
3000
3980
5295
6490
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
100
100
100
Inductance/– mH/km
0.238
0.238
0.353
0.33
0.329
0.311
0.292
0.277
0.267
0.259
0.258
0.25
0.245
0.241
Capacitance – μF/KM
0.381
0.392
0.133
0.153
0.158
0.181
0.213
0.248
0.26
0.282
0.288
0.325
0.333
0.366
DC Resistance max @ 20°c - Ώ/km
0.0762
0.0607
12.2
7.56
4.7
3.11
1.84
1.16
0.734
0.529
0.391
0.27
0.195
0.154
DC Resistance max @ 90°c - Ώ/km
0.108
0.087
15.555
9.639
5.993
3.965
2.346
1.479
0.936
0.674
0.499
0.344
0.271
0.214
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
UKOOA Code (EVA))
WB20D
WB20E
WB302
WB303
WB304
WB306
WB310
WB316
WB325
WB335
WB350
WB370
WB395
WB30A
UKOOA Code (CSP)
LB20D
LB20E
LB302
LB303
LB304
LB306
LB310
LB316
LB325
LB335
LB350
LB370
LB395
LB30A
Datasheet Ref: OFS-BS-PC-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000V Flame Retardant
Offshore Instrumentation to BS6883 Specification Offshore Power CablesCables to BS6883 Specification
Multicore Armoured Power/Control Cables - Table 3/5 Cable
3 x 150
3 x 185
3 x 240
3 x 300
4 x 1.5
4 x 2.5
4x4
4x6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
Stranding mm
37/2.25
37/2.52
61/2.25
61/2.52
7/0.53
7/0.67
7/0.85
7/1.00
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
Insulation Thickness mm
1.8
2
2.2
2.4
0.8
0.8
1
1
1
1
1.2
1.2
1.4
1.4
Thickness of Inner Sheath mm
-
-
-
-
1.1
1.1
1.2
1.3
1.4
1.5
1.7
1.8
1.9
2.1
Diameter over Inner Sheath (min/max) mm
47.5/49.5
53.0/55.0
60.0/62.0
66.8/68.8
10.2/12.2
11.2/13.2
13.7/15.7
15.3/17.3
17.7/19.7
20.7/22.7
26.0/28.0
28.4/30.4
32.7/34.7
37.5/39.5
Diameter of Armour/Braid mm
0.45
0.45
0.45
0.45
0.3
0.3
0.3
0.3
0.3
0.3
0.45
0.45
0.45
0.45
Thickness of Outer Sheath mm
-
-
-
-
1.3
1.3
1.4
1.5
1.6
1.7
1.9
2
2.2
2.4
Overall Diameter (min/max) mm
56.0/58.0
61.9/63.9
64.2/66.2
76.7/78.7
14.6/16.6
15.6/17.6
18.3/20.3
20.3/22.3
22.9/24.9
25.9/27.9
32.6/34.6
35.1/37.1
39.9/41.9
45.1/47.1
Gland Size
E
E
F
G
A
A
A
B
B
C
C2
C2
D
D
Weight kg/km
7690
9550
12400
14900
360
470
620
760
1100
1500
2100
2700
3400
4600
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
100
100
100
Inductance/– mH/km
0.24
0.241
0.238
0.238
0.353
0.33
0.329
0.311
0.292
0.277
0.267
0.0259
0.258
0.25 0.325
Capacitance – μF/KM
0.369
0.374
0.381
0.392
0.133
0.153
0.158
0.181
0.213
0.248
0.26
0.282
0.288
DC Resistance max @ 20°c - Ώ/km
0.126
0.1
0.076
0.0607
12.2
7.56
4.7
3.11
1.84
1.16
0.734
0.529
0.391
0.27
DC Resistance max @ 90°c - Ώ/km
0.175
0.14
0.108
0.087
15.555
9.639
5.993
3.965
2.346
1.479
0.936
0.674
0.499
0.344
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
UKOOA Code (EVA)
WB30B
WB30C
WB30D
WB30E
WB402
WB403
WB404
WB406
WB410
WB416
WB425
WB435
WB450
WB470
UKOOA Code (CSP)
LB30B
LB30C
LB30D
LB30E
LB402
LB403
LB404
LB406
LB410
LB416
LB425
LB435
LB450
LB470
Multicore Armoured Power/Control Cables - Table 4/5 Cable
4 x 95
4 x 120
4 x 150
4 x 185
4 x 240
4 x 300
5 x 1.5
5 x 2.5
5x4
7 x 1.5
7 x 2.5
7x4
10 x 1.5
10 x 2.5
Stranding mm
37/1.78
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
7/0.53
7/0.67
7/0.85
7/0.53
7/0.67
7/0.85
7/0.53
7/0.67
Insulation Thickness mm
1.6
1.6
1.8
2
2.2
2.4
0.8
0.8
1
0.8
0.8
1
0.8
0.8
Thickness of Inner Sheath mm
2.3
-
-
-
-
-
1.1
-
-
1.2
1.2
-
-
-
Diameter over Inner Sheath (min/max) mm
43.3/45.3
47.9/49.9
53.1/55.1
59.1/61.1
67.1/69.1
74.7/76.7
11.1/13.1
12.5/14.5
15.3/17.3
12.4/14.4
13.6/15.6
16.7/18.7
16.0/18.0
17.8/19.8 0.3
Diameter of Armour/Braid mm
0.45
0.45
0.45
0.45
0.45
0.45
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Thickness of Outer Sheath mm
2.6
-
-
-
-
-
1.3
-
-
1.3
1.4
-
-
-
Overall Diameter (min/max) mm
51.3/53.3
56.4/58.4
62.1/64.1
68.4/70.4
77.1/79.1
85.3/87.3
15.5/17.5
16.8/18.8
20.2/22.2
16.8/18.8
18.2.6/20.2
21.7/23.7
21.0/23.0
22.8./24.8
Gland Size
E
E
E
E
G
G
A
A
B
A
A
B
B
B
Weight kg/km
5700
6900
8200
10260
13200
16300
420
550
720
520
600
800
720
810
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
85 100
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
100
100
Inductance/– mH/km
0.245
0.241
0.24
0.241
0.238
0.238
0.353
0.33
0.329
0.353
0.33
-
-
-
Capacitance – μF/KM
0.333
0.366
0.369
0.374
0.381
0.392
0.133
0.153
0.158
0.133
0.153
-
-
-
DC Resistance max @ 20°c - Ώ/km
0.195
0.154
0.126
0.1
0.0762
0.0607
12.2
7.56
4.7
12.2
7.56
-
-
-
DC Resistance max @ 90°c - Ώ/km
0.271
0.214
0.175
0.14
0.108
0.087
15.555
9.639
5.993
15.555
9.639
-
-
Black
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
UKOOA Code (EVA)
WB495
WB40A
WB40B
WB40C
WB40D
WB40E
WB502
WB503
WB504
WB702
WB703
WB704
-
-
UKOOA Code (CSP)
LB495
LB40A
LB40B
LB40C
LB40D
LB40E
LB502
LB503
LB504
LB702
LB703
LB704
-
-
Datasheet Ref: OFS-BS-PC-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000V Flame Retardant
Offshore Instrumentation to BS6883 Specification Offshore Power CablesCables to BS6883 Specification
Multicore Armoured Power/Control Cables - Table 5/5 Cable
12 x 1.5
12x2.5
19x1.5
19x2.5
27 x 1.5
27 x 2.5
30 x 1.5
30 x 2.5
37 x 1.5
37 x 2.5
30 x 1.5
30 x 2.5
Stranding mm
7/0.53
7/0.67
7/0.53
7/0.67
7/0.53
7/0.67
7/0.53
7/0.67
7/0.53
7/0.67
7/0.53
7/0.67
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.3
1.4
1.4
1.5
-
1.7
-
-
-
1.8
-
-
Diameter over Inner Sheath (min/max) mm
16.5/18.5
18.5/20.5
19.8/21.8
22.1/24.1
24.1/26.1
26.8/28.8
25.0/27.0
27.9/29.9
27.1/29.1
30.4/32.4
31.4/33.4
35.2/37.2 0.45
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.45
0.45
0.45
0.45
Thickness of Outer Sheath mm
1.5
1.6
1.6
1.7
-
1.9
-
-
-
2
-
-
Overall Diameter (min/max) mm
21.5/23.5
23.6/25.6
24.8/26.8
27.3/29.3
29.7/31.7
33.4/35.4
30.6/32.6
34.6/36.6
33.7/35.7
37.0/39.0
38.2/40.2
42.4/44.4
Gland Size
B
B
C
C
C
C2
C
C2
C2
C2
C2
D
Weight kg/km
850
950
1100
1400
1500
1800
1950
2150
2700
2950
3500
3800
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
100
Inductance/– mH/km
0.353
0.33
0.353
0.33
0.353
0.33
-
-
0.353
0.33
-
-
Capacitance – μF/KM
0.133
0.153
0.133
0.153
0.133
0.153
-
-
0.133
0.153
-
-
DC Resistance max @ 20°c - Ώ/km
12.2
7.56
12.2
7.56
12.2
7.56
-
-
12.2
7.56
-
-
DC Resistance max @ 90°c - Ώ/km
15.555
9.639
15.555
9.639
15.555
9.639
-
-
15.56
9.639
-
-
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
UKOOA Code (EVA)
WBA02
WBA03
WBB02
WBB03
WBC02
WBC03
-
-
WBD02
WBD03
-
-
UKOOA Code (CSP)
LBA02
LBA03
LBB02
LBB03
LBC02
LBC03
-
-
LBD02
LBD03
-
-
Datasheet Ref: OFS-BS-PC-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
Section 2 Offshore Power & Control Cables to BS6883/BS7917 Specification
FIRE RESISTANT
FPAL Verify
Verified No.10049350
ABS
2
BS6883
Offshore Power Cables to BS6883 Specification
BS6883 - Power Cables Single core armoured:
NEK606
600/1000 V Fire Resistant
Applicable Standards
IEEE
BS6883 / BS7917/ IEC 60092-3 BS7655 BS EN 12166 IEC 60331 part 3 (Category A) IEC-60228 Stranded class 2 or tinned annealed copper conductors to BS6360
IEC
Application This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.
Conductor Identification 1 Core – Black New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to BS6360
(2) Fire Protection
Mica Glass Tape
(3) Insulation:
EPR Complying with BS7655 GP5
(4) Bedding:
EVA – SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance and LSZH (UKOOA type YC) OR CSP – SW2 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance (UKOOA type XC)
(5) Armour:
Tinned Phosphor Bronze Wire Braid to BS2873-PB102 (now BS EN 12166)
(6) Outer Sheath:
EVA – SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance and LSZH (UKOOA type YC) OR CSP – SW2 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance (UKOOA type XC)
Datasheet Ref: OFS-BS-PC-SC-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000 V Fire Resistant
Offshore Power Cables to BS6883 Specification
Singlecore Armoured Power/Control Cables - Table 1/2 Cable
1x1.0
1x1.5
1x2.5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
Stranding mm
7/044
7/0.53
7/0.67
7/0.85
7/1.0
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
Insulation Thickness mm
0.8
0.8
0.8
1
1
1
1
1.2
1.2
1.4
Thickness of Inner Sheath mm
-
-
-
-
-
-
1.1
1.1
1.1
1.1
Diameter over Inner Sheath (min/max) mm
5.1/7.1
5.4/7.4
5.8/7.8
6.8/8.8
7.3/9.3
8.3/10.3
9.5/11.5
11.9/13.9
12.8/14.8
14.6/16.6 0.3
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Thickness of Outer Sheath mm
-
-
-
-
-
-
1.2
1.2
1.3
1.4
Overall Diameter (min/max) mm
9.0/11.0
9.3/11.3
9.7/11.7
10.8/12.8
11.3/13.3
12.5/14.5
13.7/15.7
16.3/18.3
17.4/19.4
19.2/21.2
Gland Size
O
O
O
O
O
O
O
A
A
B
Weight kg/km
158
179
200
273
357
410
504
593
777
987
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
Inductance– mH/km
-
-
-
-
0.464
0.433
0.405
0.379
0.368
0.357
Capacitance – μF/km
-
-
-
-
0.522
0.379
0.447
0.464
0.514
0.522
DC Resistance @ 20°c – Ώ/km
-
-
-
-
3.11
1.84
1.16
0.734
0.529
0.391
DC Resistance @ 90°c – Ώ/km
-
-
-
-
3.965
2.346
1.479
0.936
0.674
0.499
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
UKOOA Codes (EVA)
YC101
YC102
YC103
YC104
YC106
YC110
YC116
YC125
YC130
YC150
UKOOA Codes (CSP)
XC101
XC102
XC103
XC104
XC106
XC110
XC116
XC125
XC130
XC150
Singlecore Armoured Power/Control Cables - Table 2/2 Cable
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630
Stranding mm
19/2.14
37/1.78
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
91/2.36
91/2.65
127/2.52
Insulation Thickness mm
1.4
1.6
1.6
1.8
2
2.2
2.4
2.6
2.8
2.8
Thickness of Inner Sheath mm
1.1
1.1
1.2
1.2
1.2
1.2
1.2
-
-
-
Diameter over Inner Sheath (min/max) mm
16.5/18.5
18.9/20.9
20.9/22.9
23.1/25.1
25.5/27.5
28.8/30.8
32.0/34.0
35.9/37.9
39.9/41.9
43.8/45.8 0.45
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.45
0.45
0.45
0.45
0.45
Thickness of Outer Sheath mm
1.4
1.5
1.6
1.6
1.7
1.8
1.9
-
-
-
Overall Diameter (min/max) mm
21.4/23.4
24.0/26.0
26.1/28.1
28.5/30.5
32.1/34.1
35.5/37.5
39.0/41.0
43.2/45.2
47.6/49.6
51.8/53.8
Gland Size
B
B
C
C
C2
C2
C2
D
D
E
Weight kg/km
1333
1575
1838
2310
2835
3570
4410
5985
7560
9282
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
Inductance– mH/km
0.341
0.33
0.321
0.318
0.319
0.31
0.306
0.301
0.296
0.289
Capacitance – μF/km
0.609
0.628
0.694
0.694
0.705
0.727
0.75
0.793
0.821
0.904
DC Resistance @ 20°c – Ώ/km
0.27
0.195
0.154
0.126
0.1
0.0762
0.0607
0.0475
0.0369
0.0286
DC Resistance @ 90°c – Ώ/km
0.344
0.271
0.214
0.175
0.14
0.108
0.087
0.069
0.058
0.045
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
UKOOA Codes (EVA)
YC170
YC195
YC10A
YC10B
YC10C
YC10D
YC10E
YC10F
YC10G
YC10H
UKOOA Codes (CSP)
XC170
XC195
XC10A
XC10B
XC10C
XC10D
XC10E
XC10F
XC10G
XC10H
Datasheet Ref: OFS-BS-PC-SC-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 600/1000 V Fire Resistant
BS6883 - Power Cables Multi core armoured:
NEK606
Offshore Power Cables to BS6883 Specification Applicable Standards
IEEE
BS6883 / BS7917/ IEC 60092-3 BS7655 BS EN 10257-1 IEC 60331 part 3 (Category A) IEC-60228 Stranded class 2 or tinned annealed copper conductors to BS6360
Application IEC
This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.
Conductor Identification 1 2 3 4 5 Note: picture is for illustration purposes only
Core Core Core Core Core
– White – White and Numbered (Red, Black on Request) – White and Numbered (Red, Yellow, Blue on Request) – White and numbered (Red, Yellow, Blue, Black on Request) & Above – White and Numbered
New harmonised core colours or project specified colours can be supplied upon special request
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to BS6360
(2) Fire Protection
Mica Glass Tape
(3) Insulation:
EPR Complying with BS7655 GP5
(4) Bedding:
EVA – SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance and LSZH (UKOOA type YD) OR CSP – SW2 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance (UKOOA type XD)
(5) Armour:
Galvanised Steel Wire Braid to BS EN 10257-1
(6) Outer Sheath:
EVA – SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance and LSZH (UKOOA type YD) OR CSP – SW2 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance (UKOOA type XD)
Datasheet Ref: OFS-BS-PC-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000 V Fire Resistant
Offshore Power Cables to BS6883 Specification
Multicore Armoured Power/Control Cables - Table 1/5 Cable
2 x1.5
2 x 2.5
2x4
2x6
2 x10
2 x 16
2 x 25
2 x 35
2 x 50
2 x 70
2 x 95
2 x 120
2x150
2 x 185
Stranding mm
7/0.53
7/0.67
7/0.85
7/1.00
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
37/1.78
37/2.03
37/2.25
37/2.52
Insulation Thickness mm
0.8
0.8
1
1
1
1
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2
Thickness of Inner Sheath mm
1.1
1.1
1.2
1.2
1.3
1.4
-
1.6
-
-
-
-
-
-
Diameter over Inner Sheath (min/max) mm
9.7/11.7
10.6/12.6
12.7/14.7
13.8/15.8
15.9/17.9
18.2/20.2
22.7/24.7
24.7/26.7
28.2/30.2
32.3/34.3
37.0/39.0
40.8/42.8
45.0/47.0
50.0/52.0 0.45
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.45
0.45
0.45
Thickness of Outer Sheath mm
1.2
1.2
1.3
1.4
1.4
1.5
-
1.8
-
-
-
-
-
-
Overall Diameter (min/max) mm
13.9/15.9
14.7/16.7
17.1/19.1
18.3/20.3
20.7/22.7
23.2/25.2
27.9/29.9
30.1/32.1
34.9/36.9
39.2/41.2
44.5/46.5
48.6/50.6
53.1/55.1
58.2/60.2
Gland Size
O
A
A
A
B
B
C
C
C2
D
D
D
E
E
Weight kg/km
270
310
430
520
680
850
1500
1810
2510
3230
4220
5125
6210
7500
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
100
100
100
Inductance/– mH/km
0.391
0.371
0.353
0.332
0.316
0.304
0.283
0.278
0.272
0.264
0.259
0.254
0.251
0.25 0.323
Capacitance – μF/KM
0.112
0.126
0.14
0.157
0.18
0.201
0.223
0.232
0.248
0.274
0.286
0.303
0.315
DC Resistance max @ 20°c - Ώ/km
12.2
7.56
4.7
3.11
1.84
1.16
0.734
0.529
0.391
0.27
0.195
0.154
0.126
0.1
DC Resistance max @ 90°c - Ώ/km
15.555
9.639
5.993
3.965
2.346
1.479
0.936
0.674
0.499
0.344
0.271
0.214
0.175
0.14
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
UKOOA Code (EVA)
YD202
YD203
YD204
YD206
YD210
YD216
YD225
YD235
YD250
YD270
YD295
YD20A
YD20B
YD20C
UKOOA Code (CSP)
XD202
XD203
XD204
XD206
XD210
XD216
XD225
XD235
XD250
XD270
XD295
XD20A
XD20B
XD20C
Multicore Armoured Power/Control Cables - Table 2/5 Cable
2 x 240
2 x 300
3 x 1.5
3 x 2.5
3x4
3x6
3 x 10
3 x 16
3 x 25
3 x 35
3 x 50
3 x 70
3 x 95
3x120
Stranding mm
61/2.25
61/2.52
7/0.53
7/0.67
7/0.85
7/1.0
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
37/1.78
37/2.03
Insulation Thickness mm
2.2
2.4
0.8
0.8
1
1
1
1
1.2
1.2
1.4
1.4
1.6
1.6
Thickness of Inner Sheath mm
-
-
1.1
1.1
1.2
1.2
1.3
1.4
1.6
1.7
1.8
2
2.2
-
Diameter over Inner Sheath (min/max) mm
56.7/58.7
63.0/65.0
10.8/12.8
11.7/13.7
13.9/15.9
15.2/17.2
17.4/19.4
19.9/21.9
24.9/26.9
27.0/29.0
30.9/32.9
35.2/37.2
40.3/42.3
44.4/46.4 0.45
Diameter of Armour/Braid mm
0.45
0.45
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.45
0.45
0.45
0.45
Thickness of Outer Sheath mm
-
-
1.2
1.3
1.3
1.4
1.5
1.6
1.8
1.9
2
2.2
2.4
-
Overall Diameter (min/max) mm
65.9/67.9
72.5/74.5
14.9/16.9
16.1/18.1
18.3/20.3
19.8/21.8
22.4/24.4
25.0/27.0
30.3/32.3
33.6/35.6
37.5/39.5
42.4/44.4
47.9/49.9
52.5/54.5
Gland Size
F
F
A
A
A
B
B
C
C
C2
C2
D
D
E
Weight kg/km
9440
11500
290
390
520
620
850
1150
1600
2200
3000
3980
5295
6490
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
100
100
100
Inductance/– mH/km
0.244
0.243
0.391
0.371
0.353
0.332
0.316
0.304
0.283
0.278
0.272
0.264
0.259
0.254
Capacitance – μF/KM
0.348
0.357
0.112
0.126
0.14
0.157
0.18
0.201
0.223
0.232
0.248
0.274
0.286
0.303
DC Resistance max @ 20°c - Ώ/km
0.0762
0.0607
12.2
7.56
4.7
3.11
1.84
1.16
0.734
0.529
0.391
0.27
0.195
0.154
DC Resistance max @ 90°c - Ώ/km
0.108
0.087
15.555
9.639
5.993
3.965
2.346
1.479
0.936
0.674
0.499
0.344
0.271
0.214
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
UKOOA Code (EVA)
YD20D
YD20E
YD302
YD303
YD304
YD306
YD310
YD316
YD325
YD335
YD350
YD370
YD395
YD30A
UKOOA Code (CSP)
XD20D
XD20E
XD302
XD303
XD304
XD306
XD310
XD316
XD325
XD335
XD350
XD370
XD395
XD30A
Datasheet Ref: OFS-BS-PC-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000 V Fire Resistant
Offshore Power Cables to BS6883 Specification
Multicore Armoured Power/Control Cables - Table 3/5 Cable
3 x 150
3 x 185
3 x 240
3 x 300
4 x 1.5
4 x 2.5
4x4
4x6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
Stranding mm
37/2.25
37/2.52
61/2.25
61/2.52
7/0.53
7/0.67
7/0.85
7/1.00
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
Insulation Thickness mm
1.8
2
2.2
2.4
0.8
0.8
1
1
1
1
1.2
1.2
1.4
1.4
Thickness of Inner Sheath mm
-
-
-
-
1.1
1.1
1.2
1.3
-
-
-
1.8
-
2.1
Diameter over Inner Sheath (min/max) mm
49.0/51.0
54.5/56.5
61.5/63.5
68.3/70.3
12.1/14.1
13.1/15.1
15.6/17.6
17.2/19.2
19.7/21.7
22.5/24.5
28.4/30.4
31.1/33.1
36.2/38.2
41.4/43.4 0.45
Diameter of Armour/Braid mm
0.45
0.45
0.45
0.45
0.3
0.3
0.3
0.3
0.3
0.3
0.45
0.45
0.45
Thickness of Outer Sheath mm
-
-
-
-
1.3
1.3
1.4
1.5
-
-
-
2
-
2.4
Overall Diameter (min/max) mm
57.5/59.5
63.4/65.4
65.7/67.7
78.2/80.2
15.3/17.3
16.3/18.3
19.0/21.0
20.8/22.8
23.5/25.5
26.5/28.5
33.1/35.1
36.0/38.0
41.5/43.5
47.1/49.1
Gland Size
E
F
F
G
A
A
B
B
B
C
C2
C2
D
D
Weight kg/km
7690
9550
12400
14900
360
470
620
760
1100
1500
2100
2700
3400
4600
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
100
100
100
Inductance/– mH/km
0.251
0.25
0.244
0.243
0.391
0.371
0.353
0.332
0.316
0.304
0.283
0.278
0.272
0.264 0.274
Capacitance – μF/KM
0.315
0.323
0.348
0.357
0.112
0.126
0.14
0.157
0.18
0.201
0.223
0.232
0.248
DC Resistance max @ 20°c - Ώ/km
0.126
0.1
0.0762
0.0607
12.2
7.56
4.7
3.11
1.84
1.16
0.734
0.529
0.391
0.27
DC Resistance max @ 90°c - Ώ/km
0.175
0.14
0.108
0.087
15.555
9.639
5.993
3.965
2.346
1.479
0.936
0.674
0.499
0.344
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
UKOOA Code (EVA)
YD30B
YD30C
YD30D
YD30F
YD402
YD403
YD404
YD406
YD410
YD416
YD425
YD435
YD450
YD470
UKOOA Code (CSP)
XD30B
XD30C
XD30D
XD30F
XD402
XD403
XD404
XD406
XD410
XD416
XD425
XD435
XD450
XD470
Multicore Armoured Power/Control Cables - Table 4/5 Cable
4 x 95
4 x 120
4 x 150
4 x 185
4 x 240
4 x 300
5 x 1.5
5 x 2.5
5x4
7 x 1.5
7 x 2.5
7x4
10 x 1.5
10 x 2.5
Stranding mm
37/1.78
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
7/0.53
7/0.67
7/0.85
7/0.53
7/0.67
7/0.85
7/0.53
7/0.67
Insulation Thickness mm
1.6
1.6
1.8
2
2.2
2.4
0.8
0.8
1
0.8
0.8
1
0.8
0.8
Thickness of Inner Sheath mm
-
-
-
-
-
-
-
-
-
1.2
1.2
-
-
-
Diameter over Inner Sheath (min/max) mm
47.2/49.2
49.9/51.9
55.1/57.1
61.1/63.1
69.1/71.1
76.7/78.7
13.1/15.1
14.4/16.4
17.4/19.4
12.7/14.7
15.9/17.9
-
-
0.3
Diameter of Armour/Braid mm
0.45
0.45
0.45
0.45
0.45
0.45
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Thickness of Outer Sheath mm
-
-
-
-
-
-
-
-
-
1.3
1.4
-
-
-
Overall Diameter (min/max) mm
53.3/55.3
58.4/60.4
64.1/66.1
70.4/72.4
79.1/81.1
87.3/89.3
16.3/18.3
17.6./19.6
21.0/23.0
17.6/19.6
19.3./21.3
22.7/24.7
23.3/25.3
24.1./26.1
Gland Size
E
E
F
F
G
G
A
A
B
A
B
B
B
C
Weight kg/km
5700
6900
8200
10260
13200
16300
420
550
720
520
600
800
720
810
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
85 100
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
100
100
Inductance/– mH/km
0.259
0.254
0.251
0.25
0.244
0.243
0.391
0.371
0.353
0.391
0.371
-
-
-
Capacitance – μF/KM
0.286
0.303
0.315
0.323
0.348
0.357
0.112
0.126
0.14
0.112
0.126
-
-
-
DC Resistance max @ 20°c - Ώ/km
0.195
0.154
0.126
0.1
0.0762
0.0607
12.2
7.56
4.7
12.2
7.56
-
-
-
DC Resistance max @ 90°c - Ώ/km
0.271
0.214
0.175
0.14
0.108
0.087
15.555
9.639
5.993
15.555
9.639
-
-
Black
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
UKOOA Code (EVA)
YD495
YD40A
YD40B
YD40C
YD40D
YD40E
YD502
YD503
YD504
YD702
YD703
-
-
-
UKOOA Code (CSP)
XD495
XD40A
XD40B
XD40C
XD40D
XD40E
XD502
XD503
XD504
XD702
XD703
-
-
-
Datasheet Ref: OFS-BS-PC-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000 V Fire Resistant
Offshore Power Cables to BS6883 Specification
Multicore Armoured Power/Control Cables - Table 5/5 Cable
12 x 1.5
12x2.5
19x1.5
19x2.5
27 x 1.5
27 x 2.5
30 x 1.5
30 x 2.5
37 x 1.5
37 x 2.5
48 x 1.5
48 x 2.5
Stranding mm
7/0.53
7/0.67
7/0.53
7/0.67
7/0.53
7/0.67
7/0.53
7/0.67
7/0.53
7/0.67
7/0.53
7/0.67
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.3
1.4
-
1.5
-
1.7
-
-
-
-
-
-
Diameter over Inner Sheath (min/max) mm
18.6/20.6
20.8/22.8
23.3/25.3
25.8/27.8
28.0/30.0
31.0/33.0
-
-
31.01/33.01
34.9/36.9
-
0.45
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.3
0.45
0.3
0.45
0.45
0.45
0.45
Thickness of Outer Sheath mm
1.5
1.6
-
1.7
-
1.9
-
-
-
-
-
-
Overall Diameter (min/max) mm
22.2/24.2
24.6/26.6
27.1/29.1
29.8/31.8
32.2/34.2
35.7/37.7
33.2/35.2
36.9/38.9
35.72/37.72
39.8/41.8
40.67/42.67
45.3/47.3
Gland Size
A
C
C
C
C2
C2
C2
C2
C2
D
D
D
Weight kg/km
850
950
1100
1400
1500
1800
1950
2150
2700
2950
3500
3860
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85 100
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
Inductance/– mH/km
0.391
0.371
0.391
0.371
0.391
0.371
-
-
0.391
0.371
-
-
Capacitance – μF/KM
0.112
0.126
0.112
0.126
0.112
0.126
-
-
0.112
0.126
-
-
DC Resistance max @ 20°c - Ώ/km
12.2
7.56
12.2
7.56
12.2
7.56
-
-
12.2
7.56
-
DC Resistance max @ 90°c - Ώ/km
15.555
9.639
15.555
9.639
15.555
9.639
-
-
15.555
9.639
-
-
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
UKOOA Code (EVA)
YDA02
YDA03
YDB02
YDB03
YDC02
YDC03
-
-
YDD02
YDD03
-
-
UKOOA Code (CSP)
XDA02
XDA03
XDB02
XDB03
XDC02
XDC03
-
-
XDD02
XDD03
-
-
Datasheet Ref: OFS-BS-PC-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
Section 3 Medium Voltage Power Cables to BS6883 Specification
FLAME RETARDANT
FPAL Verify
Verified No.10049350
ABS
3
BS6883 3.8/6.6kV Flame Retardant
NEK606
Medium Voltage Power Cable to BS6883 Specification
BS6883 – Power CablesSingle Core Armoured:
Applicable Standards IEEE
BS6883 / IEC 60092-3 BS7655-1.2 BS EN 12166 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to BS6360
IEC
Application This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.
Conductor Identification One Core – Black New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Stranded Class 2 Tinned Annealed Copper Conductor to BS6360
(2) Conductor Screen:
Semi-conductive tape or an extruded layer of semi-conductive compound
(3) Insulation:
Halogen Free Ethylene Propylene Rubber (EPR) Complying with BS7655-1.2 Type GP5
(4) Insulation Screen:
Semi-Conductive tape or an extruded layer of semi-conductive compound
(5) Metallic Screen:
Copper Tape - Note the tape may be tinned or plain
(6) Bedding:
CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type MA PET Tape
(7) Armour:
Singlecore- Tinned phosphor bronze wire braid to BS2873-PB102 (now BS EN 12166) PET Tape
(8) Outer Sheah:
CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type MA
Datasheet Ref: OFS-BS-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
3.8/6.6kV Flame Retardant
Medium Voltage Power Cables to BS6883 Specification
Single Core Armoured Power Cables Number of cores
No.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Nominal area of conductor
mm²
16
25
35
50
70
95
120
150
185
240
300
400
500
630
Insulation radial thickness
mm
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
Inner sheath radial thickness
mm
1.30
1.30
1.40
1.40
1.50
1.60
1.60
1.70
1.80
1.90
2.00
2.10
2.30
2.40
Tinned phosphor bronze wire braid diameter
mm
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.45
0.45
0.45
0.45
0.45
0.45
0.45
Outer sheath radial thickness
mm
1.40
1.50
1.50
1.60
1.70
1.80
1.80
1.90
2.00
2.10
2.20
2.40
2.50
2.70
Overall diameter (Nom)
mm
21.30
23.00
24.00
25.40
27.40
29.60
31.30
33.80
36.00
40.40
43.40
47.30
51.70
55.90
Cable weight (Nom) Internal bending radius (Min)
Kg/Km
-
-
-
-
-
-
-
-
-
-
-
-
-
-
mm
448
484
504
530
572
614
652
704
746
836
900
978
1070
1154
Braid resistance @ 20°C (Max)
/Km
11.76
10.16
10.16
8.91
8.07
8.07
8.51
6.91
6.91
5.89
5.37
5.37
5.16
3.58
Armour gross cross sectional area
mm²
11.88
13.57
13.57
15.27
16.96
16.96
16.96
26.72
26.72
30.54
34.35
34.35
38.17
45.80
d.c. conductor resistance @ 20°C (Max)
/Km
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
0.0475
0.0369
0.0286
a.c. conductor resistance @ 20°C (Max)
/Km
1.48
0.936
0.675
0.499
0.345
0.249
0.197
0.162
0.129
0.0996
0.0805
0.0646
0.0523
0.0429
Inductive reactance @ 60 Hz +
/Km
0.198
0.179
0.173
0.165
0.157
0.148
0.144
0.142
0.138
0.129
0.126
0.122
0.120
0.117
Impedance @ 60 Hz
/Km
1.49
0.953
0.697
0.526
0.379
0.290
0.244
0.215
0.189
0.163
0.150
0.138
0.131
0.124
DC voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Single phase voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Three phase voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
-
-
-
-
A
95
125
155
190
240
290
340
385
440
520
590
670
720
780 62.90
Continuous current carrying capacity @ 45°C * Conductor short circuit symmetrical fault 90°C - 160°C for 1 sec
kA rms
-
-
-
-
6.99
9.49
12.00
15.00
18.50
24.00
30.00
40.00
49.90
90°C - 250°C for 1 sec Braid short circuit asymmetrical earth fault 80°C - 220°C for 1 sec
kA rms
2.29
3.58
5.01
7.15
-
-
-
-
-
-
-
-
-
-
kA rms
0.724
0.828
0.828
0.931
1.035
1.035
1.035
1.630
1.630
1.863
2.096
2.096
2.328
2.794
UKOOA Code
MA116 MA125 MA135 MA150 MA170 MA195 MA10A MA10B MA10C MA10D MA10E MA10F MA10G MA10H
Datasheet Ref: OFS-BS-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 3.8/6.6kV Flame Retardant
BS6883 – Power CablesMulti Core Armoured:
NEK606
Medium Voltage Power Cable to BS6883 Specification
Applicable Standards
IEEE
BS6883 / IEC 60092-3 BS7655-1.2 BS EN 10257-1 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to BS6360
Application IEC
This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.
Conductor Identification The cores of three-core cables shall be identified by one of the following methods a) printing 1,2,3 on the semiconducting insulation screen tape b) coloured insulation (red, yellow, blue) c) coloured tapes (red, yellow, blue) d) numbered tapes e) printing colours (red, yellow, blue) on the semi-conducting insulation screen tape
Note: picture is for illustration purposes only
New harmonised core colours or project specified colours can be supplied upon special request
Construction
Specifications
(1) Conductor:
Stranded Class 2 Tinned Annealed Copper Conductor to BS6360
(2) Conductor Screen:
Semi-conductive tape or an extruded layer of semi-conductive compound
(3) Insulation:
Halogen Free Ethylene Propylene Rubber (EPR) Complying with BS7655-1.2 Type GP5
(4) Insulation Screen:
Semi-Conductive tape or an extruded layer of semi-conductive compound
(5) Metallic Screen:
Copper Tape - Note the tape may be tinned or plain
(6) Bedding:
CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type MB PET Tape
(7) Armour:
3 Core- Galvanised Mild Steel Wire Braid to BS EN 10257-1 PET Tape
(8) Outer Sheah:
CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type MB
Datasheet Ref: OFS-BS-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
3.8/6.6kV Flame Retardant
Medium Voltage Power Cables to BS6883 Specification
Multi Core Armoured Power Cables Number of cores
No.
3
3
3
3
3
3
3
3
3
3
3
Nominal area of conductor
mm²
16
25
35
50
70
95
120
150
185
240
300
Insulation radial thickness
mm
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
Inner sheath radial thickness
mm
1.80
2.00
2.00
2.20
2.30
2.50
2.60
2.70
2.90
3.10
3.30
Galvanised steel wire braid diameter
mm
0.45
0.45
0.45
0.45
0.45
0.45
0.45
0.45
0.45
0.45
0.45
Outer sheath radial thickness
mm
2.10
2.20
2.30
2.40
2.60
2.80
2.90
3.10
3.20
3.50
3.70
Overall diameter (Nom)
mm
39.10
43.10
45.10
48.20
52.60
57.30
60.80
64.60
69.00
78.90
85.10 1313
Cable weight (Nom)
Kg/Km mm
599
671
695
747
815
884
938
999
1064
1215
Braid resistance @ 20°C (Max)
Ω/Km
7.19
7.19
6.50
6.50
6.30
4.37
4.09
4.09
3.36
3.30
2.96
Armour gross cross sectional area
mm²
30.54
30.54
34.35
34.35
38.17
45.80
51.53
51.53
57.26
62.98
68.71
d.c. conductor resistance @ 20°C (Max)
Ω/Km
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
a.c. conductor resistance @ 20°C (Max)
Ω/Km
1.48
0.936
0.675
0.499
0.345
0.250
0.198
0.163
0.130
0.101
0.0825
Inductive reactance @ 60 Hz +
Ω/Km
0.152
0.136
0.131
0.125
0.119
0.112
0.109
0.106
0.103
0.0981
0.0958
Internal bending radius (Min)
Ω/Km
1.49
0.946
0.687
0.515
0.365
0.274
0.226
0.194
0.166
0.141
0.126
DC voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
-
Single phase voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
-
Three phase voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
-
A
67
89
105
135
170
205
240
270
305
365
415 30.00
Impedance @ 60 Hz
Continuous current carrying capacity @ 45°C * Conductor short circuit symmetrical fault 90°C - 160°C for 1 sec
kA rms
-
-
-
-
6.99
9.49
12.00
15.00
18.50
24.00
90°C - 250°C for 1 sec Braid short circuit asymmetrical earth fault 80°C - 220°C for 1 sec UKOOA Code
kA rms
2.29
3.58
5.01
7.15
-
-
-
-
-
-
-
kA rms
1.527
1.527
1.718
1.718
1.909
2.290
2.576
2.576
2.863
3.149
3.435
MB316 MB325 MB335 MB350 MB370 MB395 MB30A MB30B MB30C MB30D MB30E
Datasheet Ref: OFS-BS-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 6.35/11kV Flame Retardant
NEK606
Medium Voltage Power Cable to BS6883 Specification
BS6883 – Power CablesSingle Core Armoured:
Applicable Standards IEEE
BS6883 / IEC 60092-3 BS7655-1.2 BS EN 12166 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to BS6360
IEC
Application This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.
Conductor Identification One Core – Black New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Stranded Class 2 Tinned Annealed Copper Conductor to BS6360
(2) Conductor Screen:
Semi-conductive tape or an extruded layer of semi-conductive compound
(3) Insulation:
Halogen Free Ethylene Propylene Rubber (EPR) Complying with BS7655-1.2 Type GP5
(4) Insulation Screen:
Semi-Conductive tape or an extruded layer of semi-conductive compound
(5) Metallic Screen:
Copper Tape - Note the tape may be tinned or plain
(6) Bedding:
CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type PA PET Tape
(7) Armour:
Singlecore- Tinned phosphor bronze wire braid to BS2873-PB102 (now BS EN 12166) PET Tape
(8) Outer Sheah:
CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type PA
Datasheet Ref: OFS-BS-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
6.35/11kV Flame Retardant
Medium Voltage Power Cables to BS6883 Specification
Single Core Armoured Power Cables Number of cores
No.
1
1
1
1
1
1
Nominal area of conductor
mm²
16.00
25.00
35.00
50.00
70.00
95.00
Insulation radial thickness
mm
3.40
3.40
3.40
3.40
3.40
3.40
3.40
3.40
Inner sheath radial thickness
mm
1.30
1.40
1.40
1.50
1.50
1.60
1.70
1.70
Tinned phosphor bronze wire braid diameter
mm
0.30
0.30
0.30
0.30
0.30
0.30
0.45
Outer sheath radial thickness
mm
1.50
1.50
1.60
1.60
1.70
1.80
Overall diameter (Nom)
mm
22.30
24.10
25.10
26.40
28.30
30.50
Cable weight (Nom) Internal bending radius (Min)
1
1
1
1
1
1
1
1
240.00
300.00
400.00
500.00
630.00
3.40
3.40
3.40
3.40
3.40
3.40
1.80
1.90
2.00
2.10
2.30
2.40
0.45
0.45
0.45
0.45
0.45
0.45
0.45
1.90
2.00
2.00
2.20
2.30
2.40
2.50
2.70
33.30
34.90
36.80
41.60
44.50
48.20
52.10
56.40
120.00 150.00 185.00
Kg/Km
-
-
-
-
-
-
-
-
-
-
-
-
-
-
mm
470
504
524
552
588
634
692
724
764
864
920
994
1078
1162
Braid resistance @ 20°C (Max)
/Km
10.16
10.16
8.91
8.91
8.07
8.51
6.91
6.91
6.91
5.89
5.37
5.37
5.16
3.58
Armour gross cross sectional area
mm²
13.57
13.57
15.27
15.27
16.96
16.96
26.72
26.72
26.72
30.54
34.35
34.35
38.17
45.80
d.c. conductor resistance @ 20°C (Max)
/Km
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
0.0475
0.0369
0.0286
a.c. conductor resistance @ 20°C (Max)
/Km
1.48
0.936
0.675
0.499
0.345
0.249
0.197
0.162
0.129
0.0995
0.0804
0.0646
0.0521
0.0434
Inductive reactance @ 60 Hz +
/Km
0.197
0.179
0.172
0.165
0.156
0.147
0.146
0.141
0.137
0.129
0.126
0.121
0.118
0.109
Impedance @ 60 Hz
/Km
1.49
0.953
0.696
0.525
0.378
0.290
0.245
0.215
0.188
0.163
0.149
0.137
0.129
0.118
DC voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Single phase voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Three phase voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
-
-
-
-
A
95
125
155
190
240
290
340
385
440
520
590
670
720
780 62.90
Continuous current carrying capacity @ 45°C * Conductor short circuit symmetrical fault 90°C - 160°C for 1 sec
kA rms
-
-
-
-
6.99
9.49
12.00
15.00
18.50
24.00
30.00
40.00
49.90
90°C - 250°C for 1 sec Braid short circuit asymmetrical earth fault 80°C - 220°C for 1 sec
kA rms
2.29
3.58
5.01
7.15
-
-
-
-
-
-
-
-
-
-
kA rms
0.828
0.828
0.931
0.931
1.035
1.035
1.630
1.630
1.630
1.863
2.096
2.096
2.328
2.794
PA10E
PA10F
PA10G
PA10H
UKOOA Code
PA116 PA125 PA135 PA150 PA170 PA195 PA10A PA10B PA10C PA10D
Datasheet Ref: OFS-BS-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 6.35/11kV Flame Retardant
BS6883 – Power CablesMulti Core Armoured:
NEK606
Medium Voltage Power Cable to BS6883 Specification
Applicable Standards
IEEE
BS6883 / IEC 60092-3 BS7655-1.2 BS EN 10257-1 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to BS6360
Application IEC
This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.
Conductor Identification The cores of three-core cables shall be identified by one of the following methods a) printing 1,2,3 on the semiconducting insulation screen tape b) coloured insulation (red, yellow, blue) c) coloured tapes (red, yellow, blue) d) numbered tapes e) printing colours (red, yellow, blue) on the semi-conducting insulation screen tape
Note: picture is for illustration purposes only
New harmonised core colours or project specified colours can be supplied upon special request
Construction
Specifications
(1) Conductor:
Stranded Class 2 Tinned Annealed Copper Conductor to BS6360
(2) Conductor Screen:
Semi-conductive tape or an extruded layer of semi-conductive compound
(3) Insulation:
Halogen Free Ethylene Propylene Rubber (EPR) Complying with BS7655-1.2 Type GP5
(4) Insulation Screen:
Semi-Conductive tape or an extruded layer of semi-conductive compound
(5) Metallic Screen:
Copper Tape - Note the tape may be tinned or plain
(6) Bedding:
CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type PB PET Tape
(7) Armour:
3 Core- Galvanised Mild Steel Wire Braid to BS EN 10257-1 PET Tape
(8) Outer Sheah:
CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type PB
Datasheet Ref: OFS-BS-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
6.35/11kV Flame Retardant
Medium Voltage Power Cables to BS6883 Specification
Multi Core Armoured Power Cables Number of cores
No.
3
3
3
3
3
3
3
3
3
3
3
Nominal area of conductor
mm²
16
25
35
50
70
95
120
150
185
240
300
Insulation radial thickness
mm
3.40
3.40
3.40
3.40
3.40
3.40
3.40
3.40
3.40
3.40
3.40
Inner sheath radial thickness
mm
1.90
2.00
2.10
2.20
2.40
2.50
2.70
2.80
3.00
3.20
3.40
Galvanised steel wire braid diameter
mm
0.45
0.45
0.45
0.45
0.45
0.45
0.45
0.45
0.45
0.45
0.45
Outer sheath radial thickness
mm
2.10
2.30
2.40
2.50
2.70
2.80
3.00
3.10
3.30
3.60
3.80
Overall diameter (Nom)
mm
41.30
45.10
47.30
50.20
54.80
61.00
63.20
66.60
71.20
81.10
87.30 1343
Cable weight (Nom)
Kg/Km mm
642
695
734
777
848
914
977
1029
1097
1248
Braid resistance @ 20°C (Max)
Ω/Km
7.19
6.50
6.50
6.30
4.37
4.37
4.09
3.36
3.18
3.30
3.27
Armour gross cross sectional area
mm²
30.54
34.35
34.35
38.17
45.80
45.80
51.53
57.26
62.98
62.98
68.71
d.c. conductor resistance @ 20°C (Max)
Ω/Km
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
a.c. conductor resistance @ 20°C (Max)
Ω/Km
1.48
0.936
0.675
0.499
0.345
0.250
0.198
0.163
0.130
0.101
0.0823
Inductive reactance @ 60 Hz +
Ω/Km
0.157
0.141
0.135
0.129
0.122
0.116
0.112
0.109
0.106
0.100
0.0979
Impedance @ 60 Hz
Ω/Km
1.49
0.947
0.688
0.516
0.366
0.275
0.227
0.196
0.168
0.142
0.128
DC voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
-
Single phase voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
-
Three phase voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
-
A
67
89
105
135
170
205
240
270
305
365
415 30.00
Internal bending radius (Min)
Continuous current carrying capacity @ 45°C * Conductor short circuit symmetrical fault 90°C - 160°C for 1 sec
kA rms
-
-
-
-
6.99
9.49
12.00
15.00
18.50
24.00
90°C - 250°C for 1 sec Braid short circuit asymmetrical earth fault 80°C - 220°C for 1 sec UKOOA Code
kA rms
2.29
3.58
5.01
7.15
-
-
-
-
-
-
-
kA rms
1.527
1.718
1.718
1.909
2.290
2.290
2.576
2.863
3.149
3.149
3.435
PB316 PB325 PB335 PB350 PB370 PB395 PB30A PB30B PB30C PB30D
PB30E
Datasheet Ref: OFS-BS-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 8.7/15kV Flame Retardant
NEK606
Medium Voltage Power Cable to BS6883 Specification
BS6883 – Power CablesSingle Core Armoured:
Applicable Standards IEEE
BS6883 / IEC 60092-3 BS7655-1.2 BS EN 12166 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to BS6360
IEC
Application This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.
Conductor Identification One Core – Black New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Stranded Class 2 Tinned Annealed Copper Conductor to BS6360
(2) Conductor Screen:
Semi-conductive tape or an extruded layer of semi-conductive compound
(3) Insulation:
Halogen Free Ethylene Propylene Rubber (EPR) Complying with BS7655-1.2 Type GP5
(4) Insulation Screen:
Semi-Conductive tape or an extruded layer of semi-conductive compound
(5) Metallic Screen:
Copper Tape - Note the tape may be tinned or plain
(6) Bedding:
CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type HA PET Tape
(7) Armour:
Singlecore- Tinned phosphor bronze wire braid to BS2873-PB102 (now BS EN 12166) PET Tape
(8) Outer Sheah:
CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type HA
Datasheet Ref: OFS-BS-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
8.7/15kV Flame Retardant
Medium Voltage Power Cables to BS6883 Specification
Single Core Armoured Power Cables Number of cores
No.
1
1
1
1
1
Nominal area of conductor
mm²
25.00
35.00
50.00
70.00
95.00
Insulation radial thickness
mm
4.50
4.50
4.50
4.50
4.50
4.50
Inner sheath radial thickness
mm
1.50
1.50
1.50
1.60
1.70
1.80
Tinned phosphor bronze wire braid diameter
mm
0.30
0.30
0.30
0.30
0.45
Outer sheath radial thickness
mm
1.60
1.70
1.70
1.80
Overall diameter (Nom)
mm
26.50
27.60
28.70
30.80
Cable weight (Nom) Internal bending radius (Min)
1
1
1
1
1
1
1
1
185.00
240.00
300.00
400.00
500.00
630.00
4.50
4.50
4.50
4.50
4.50
4.50
4.50
1.80
1.90
2.00
2.10
2.20
2.40
2.50
0.45
0.45
0.45
0.45
0.45
0.45
0.45
0.45
1.90
2.00
2.10
2.10
2.20
2.40
2.50
2.60
2.80
34.00
35.70
37.40
39.30
43.90
47.00
50.60
54.60
58.80
120.00 150.00
Kg/Km
-
-
-
-
-
-
-
-
-
-
-
-
-
mm
554
574
598
638
706
740
774
814
910
970
1044
1128
1212
Braid resistance @ 20°C (Max)
/Km
8.91
8.07
8.07
8.51
6.91
6.91
6.91
5.89
5.37
5.37
5.16
3.58
3.58
Armour gross cross sectional area
mm²
15.27
16.96
16.96
16.96
26.72
26.72
26.72
30.54
34.35
34.35
38.17
45.80
45.80
d.c. conductor resistance @ 20°C (Max)
/Km
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
0.0475
0.0369
0.0286
a.c. conductor resistance @ 20°C (Max)
/Km
0.936
0.675
0.499
0.345
0.249
0.197
0.162
0.129
0.0994
0.0803
0.0644
0.0519
0.0425
Inductive reactance @ 60 Hz +
/Km
0.186
0.179
0.171
0.162
0.156
0.151
0.146
0.141
0.133
0.129
0.124
0.122
0.118
Impedance @ 60 Hz
/Km
0.954
0.698
0.527
0.381
0.294
0.248
0.218
0.191
0.166
0.152
0.140
0.132
0.126
DC voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
-
-
-
Single phase voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
-
-
-
Three phase voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
-
-
-
A
125
155
190
240
290
340
385
440
520
590
670
720
780 62.90
Continuous current carrying capacity @ 45°C * Conductor short circuit symmetrical fault 90°C - 160°C for 1 sec
kA rms
-
-
-
6.99
9.49
12.00
15.00
18.50
24.00
30.00
40.00
49.90
90°C - 250°C for 1 sec Braid short circuit asymmetrical earth fault 80°C - 220°C for 1 sec
kA rms
3.58
5.01
7.15
-
-
-
-
-
-
-
-
-
-
kA rms
0.931
1.035
1.035
1.035
1.630
1.630
1.630
1.863
2.096
2.096
2.328
2.794
2.794
HA10E
HA10F
UKOOA Code
HA125 HA135 HA150 HA170 HA195 HA10A HA10B HA10C HA10D
HA10G HA10H
Datasheet Ref: OFS-BS-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 8.7/15kV Flame Retardant
BS6883 – Power CablesMulti Core Armoured:
NEK606
Medium Voltage Power Cable to BS6883 Specification
Applicable Standards
IEEE
BS6883 / IEC 60092-3 BS7655-1.2 BS EN 10257-1 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to BS6360
Application IEC
This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.
Conductor Identification The cores of three-core cables shall be identified by one of the following methods a) printing 1,2,3 on the semiconducting insulation screen tape b) coloured insulation (red, yellow, blue) c) coloured tapes (red, yellow, blue) d) numbered tapes e) printing colours (red, yellow, blue) on the semi-conducting insulation screen tape
Note: picture is for illustration purposes only
New harmonised core colours or project specified colours can be supplied upon special request
Construction
Specifications
(1) Conductor:
Stranded Class 2 Tinned Annealed Copper Conductor to BS6360
(2) Conductor Screen:
Semi-conductive tape or an extruded layer of semi-conductive compound
(3) Insulation:
Halogen Free Ethylene Propylene Rubber (EPR) Complying with BS7655-1.2 Type GP5
(4) Insulation Screen:
Semi-Conductive tape or an extruded layer of semi-conductive compound
(5) Metallic Screen:
Copper Tape - Note the tape may be tinned or plain
(6) Bedding:
CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type HB PET Tape
(7) Armour:
3 Core- Galvanised Mild Steel Wire Braid to BS EN 10257-1 PET Tape
(8) Outer Sheah:
CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type HB
Datasheet Ref: OFS-BS-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
8.7/15kV Flame Retardant
Medium Voltage Power Cables to BS6883 Specification
Multi Core Armoured Power Cables Number of cores
No.
3
3
3
3
3
3
3
3
3
3
Nominal area of conductor
mm²
25
35
50
70
95
120
150
185
240
300
Insulation radial thickness
mm
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
Inner sheath radial thickness
mm
2.20
2.30
2.40
2.60
2.70
2.90
3.00
3.20
3.40
3.60
Galvanised steel wire braid diameter
mm
0.45
0.45
0.45
0.45
0.45
0.45
0.45
0.45
0.45
0.45
Outer sheath radial thickness
mm
2.50
2.60
2.70
2.90
3.00
3.20
3.30
3.50
3.80
4.00
Overall diameter (Nom)
mm
50.50
52.90
55.70
60.10
64.60
68.30
72.10
76.70
86.60
92.80 1431
Kg/Km
Cable weight (Nom)
mm
780
819
863
929
999
1053
1115
1184
1334
Braid resistance @ 20°C (Max)
Ω/Km
6.30
6.30
4.37
4.09
4.09
3.36
3.18
3.30
2.96
3.27
Armour gross cross sectional area
mm²
38.17
38.17
45.80
51.53
51.53
57.26
62.98
62.98
68.71
68.71
Internal bending radius (Min)
d.c. conductor resistance @ 20°C (Max)
Ω/Km
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
a.c. conductor resistance @ 20°C (Max)
Ω/Km
0.936
0.675
0.499
0.345
0.250
0.198
0.162
0.130
0.101
0.0819
Inductive reactance @ 60 Hz +
Ω/Km
0.151
0.145
0.138
0.131
0.123
0.119
0.116
0.112
0.106
0.103
Impedance @ 60 Hz
Ω/Km
0.948
0.690
0.518
0.369
0.278
0.231
0.199
0.172
0.146
0.132
DC voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
Single phase voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
Three phase voltage drop
mV/A/M
-
-
-
-
-
-
-
-
-
-
A
89
105
135
170
205
240
270
305
365
415 30.00
Continuous current carrying capacity @ 45°C * Conductor short circuit symmetrical fault 90°C - 160°C for 1 sec
kA rms
-
-
-
6.99
9.49
12.00
15.00
18.50
24.00
90°C - 250°C for 1 sec Braid short circuit asymmetrical earth fault 80°C - 220°C for 1 sec
kA rms
3.58
5.01
7.15
-
-
-
-
-
-
-
kA rms
1.909
1.909
2.290
2.576
2.576
2.863
3.149
3.149
3.435
3.435
HB325 HB335 HB350 HB370 HB395 HB30A HB30B HB30C HB30D
UKOOA Code
HB30E
Datasheet Ref: OFS-BS-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
Section 4 Offshore Instrumentation Cables to NEK 606 Specification
RFOU FLAME RETARDANT
FPAL Verify
Verified No.10049350
ABS
4
BS6883
Offshore Instrumentation Cables to NEK606 Specification
RFOU(C) Pairs/Triples Armoured Cables â&#x20AC;&#x201C; Collectively Screened:
NEK606
150/250V Flame Retardant
Applicable Standards
IEEE
NEK 606 / IEC 60092-3 IEC 60092-351 IEC 60332 part 3 (Category A) IEC 60092-359 Stranded class 2 or tinned annealed copper conductors to IEC60228
Application IEC
This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.
Conductor Identification
Single Pair: Black/ Light Blue Triples: Black/ Light Blue/ Brown New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Annealed Copper Conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Insulation:
(R) EPR Complying with IEC60092-351
(3) Collective Screen:
Aluminium or Copper Mylar Tape Screen in contact with Tinned Copper drain wire
(4) Bedding:
(F) - Flame Retardant Halogen Free Compound, PETP-tape
(5) Armour:
(O) - Tinned Copper Wire Braid to NVE FEA-M 1238.5, PETP-tape
(6) Outer Sheath:
(U) - SHF2 dual Compound thermoset rubber - IEC60092-359 Type SHF2, Dual rated as being Both halogen free and mud resistant in accordance with NEK606, and meets cold bend and Impact test (-20C) cross sectional area C22.2.
Datasheet Ref: OFS-NK-INS-CS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250V Flame Retardant
Offshore Instrumentation Cables to NEK606 Specification
RFOU(c) Pairs/Triples Armoured Cables - Table 1/2 Cable
2x2x0.75
4x2x0.75
8x2x0.75 12x2x0.75 16x2x0.75 24x2x0.75
2x2x1.5
4x2x1.5
8x2x1.5
12x2x1.5
16x2x1.5
24x2x1.5
Stranding mm
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.1
1.1
1.1
1.3
1.4
1.6
1.1
1.1
1.1
1.3
1.4
1.8
Diameter over Inner Sheath (min/max) mm
10.5/12.5
12.5/14.5
17.5/19.5
19.5/22.5
21.0./24.0
26.0/29.0
12.5/14.5
14.5/16.5
19.5/22.5
22.0/25.0
24.5/27.5
29.5/33.5 0.3
Diameter of Armour/Braid mm
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Thickness of Outer Sheath mm
1.2
1.3
1.4
1.5
1.6
1.8
1.3
1.4
1.6
1.7
1.8
2.1
Overall Diameter (min/max) mm
14.0/16.0
16.5/18.5
21.0/24.0
23.5/26.5
25.5/28.5
30.5/34.5
16.0/18.0
18.5/20.5
23.5/26.5
27.0/30.0
29.0/33.0
35.5/39.5
Gland Size
O
A
B
C
C
C2
A
A
C
C
C
C2
Weight kg/km
310
430
700
900
1080
1510
430
560
930
1260
1550
2230
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
100
Inductance/ Resistance – mH/km
0.75
0.75
0.75
0.75
0.75
0.75
0.68
0.68
0.68
0.68
0.68
0.68
Capacitance – nF/KM
80
80
80
80
80
80
90
90
90
90
90
90
DC Resistance @ 20°c – ohms/km
24.8
24.8
24.8
24.8
24.8
24.8
12.2
12.2
12.2
12.2
12.2
12.2
Sheath Colour
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/ Blue
Grey/ Blue
Grey/ Blue
RFOU(c) Pairs/Triples Armoured Cables - Table 2/2 Cable
2x3x0.75
4x3x0.75
Stranding mm
7/0.37
7/0.37
8x3x0.75 12x3x0.75 16x3x0.75 24x3x0.75 7/0.37
2x3x1.5
4x3x1.5
8x3x1.5
12x3x1.5
16x3x1.5
24x3x1.5
7/0.37
7/0.37
7/0.37
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53 0.8
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.1
1.1
1.1
1.3
1.4
1.8
1.1
1.1
1.1
1.3
1.4
1.8
Diameter over Inner Sheath (min/max) mm
12.0/14.0
14.0/16.0
18.5/21.5
21.5/24.5
24.0./27.0
29.0/33.0
14.0/16.0
16.0/18.0
21.5/24.5
25.5/28.5
28.0/31.0
34.0/38.0 0.3
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Thickness of Outer Sheath mm
1.3
1.3
1.5
1.6
1.7
2
1.4
1.4
1.7
1.8
1.9
2.2
Overall Diameter (min/max) mm
15.5/17.5
17.5/19.5
22.5/25.5
26.5/29.5
28.0/32.0
34.5/38.5
17.5/19.5
19.5/22.5
26.0/29.0
29.5/33.5
33.0/37.0
39.5/44.5
Gland Size
A
A
B
C
C
C2
A
B
C
C2
C2
D
Weight kg/km
410
530
860
1180
1430
2120
520
710
1230
1650
2050
3040
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
100
Inductance/ Resistance – mH/km
0.75
0.75
0.75
0.75
0.75
0.75
0.68
0.68
0.68
0.68
0.68
0.68
Capacitance – nF/KM
80
80
80
80
80
80
90
90
90
90
90
90
DC Resistance @ 20°c – Ohms/km
24.8
24.8
24.8
24.8
24.8
24.8
12.2
12.2
12.2
12.2
12.2
12.2
Sheath Colour
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/ Blue
Grey/ Blue
Grey/ Blue
Datasheet Ref: OFS-NK-INS-CS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883
Offshore Instrumentation Cables to NEK606 Specification
RFOU(i) Pairs/Triples Armoured Cables â&#x20AC;&#x201C; Individually Screened:
NEK606
150/250V Flame Retardant
Applicable Standards IEEE
NEK 606 / IEC 60092-3 IEC 60092-351 IEC 60332 part 3 (Category A) IEC 60092-359 Stranded class 2 or tinned annealed copper conductors to IEC60228
Application IEC
This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.
Conductor Identification Single Pair: Black/ Light Blue Triples: Black/ Light Blue/ Brown New harmonised core colours or project specified colours can be supplied upon special request
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Annealed Copper Conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Insulation:
(R) EPR Complying with IEC60092-351
(3) Individual Screen:
Aluminium or Copper Mylar Tape Screen in contact with Tinned Copper drain wire
(4) Bedding:
(F) - Flame Retardant Halogen Free Compound, PETP-tape
(5) Armour:
(O) - Tinned Copper Wire Braid to NVE FEA-M 1238.5, PETP-tape
(6) Outer Sheath:
(U) - SHF2 dual Compound thermoset rubber - IEC60092-359 Type SHF2, Dual rated as being Both halogen free and mud resistant in accordance with NEK606, and meets cold bend and Impact test (-20C) cross sectional area C22.2.
Datasheet Ref: OFS-NK-INS-IS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250V Flame Retardant
Offshore Instrumentation Cables to NEK606 Specification
RFOU(i) Pairs/Triples Armoured Cables - Table 1/2 1x2x1.5
2x2x1.5
4x2x1.5
8x2x1.5
Stranding mm
Cable
1x2x0.75 2x2x0.75 4x2x0.75 8x2x0.75 12x2x0.75 16x2x0.75 24x2x0.75 7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.53
7/0.53
7/0.53
7/0.53
12x2x1.5 16x2x1.5 24x2x1.5 7/0.53
7/0.53
7/0.53
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.1
1.1
1.1
1.1
1.3
1.4
1.6
1.1
1.1
1.1
1.1
1.3
1.4
1.8
Diameter over Inner Sheath (min/max) mm
7.2/8.8
10.5/12.5
12.5/14.5
17.5/19.5
20.0./23.0
22.5/25.5
28.0/31.0
8.2/9.8
12.5/14.5
14.5/16.5
19.5/22.5
23.5/26.5
26.5/29.5
32.5/36.5 0.4
Diameter of Armour/Braid mm
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.2
0.3
0.3
0.3
0.3
0.3
Thickness of Outer Sheath mm
1.1
1.2
1.3
1.5
1.6
1.7
1.9
1.1
1.3
1.4
1.6
1.8
1.9
2.2
Overall Diameter (min/max) mm
10.0/12.0
14.0/16.0
16.5/18.5
21.0/24.0
24.5/27.5
27.0/30.0
33.0/37.0
11.0/13.0
16.0/18.0
18.5/20.5
24.0/27.0
28.0/32.0
31.0/35.0
38.0/43.0
Gland Size
O
O
A
B
C
C
C2
O
A
A
C
C
C2
D
Weight kg/km
200
330
470
790
1080
1330
1920
240
450
620
1070
1530
1860
2760
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
100
100
100
Inductance/ Resistance – mH/km
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.68
0.68
0.68
0.68
0.68
0.68
0.68
Capacitance – nF/KM
90
90
90
90
90
90
90
110
110
110
110
110
110
110
DC Resistance @ 20°c – Ohms/km
24.8
24.8
24.8
24.8
24.8
24.8
24.8
12.2
12.2
12.2
12.2
12.2
12.2
12.2
Sheath Colour
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/ Blue
Grey/ Blue
Grey/ Blue
Grey/Blue
Grey/Blue
RFOU(i) Pairs/Triples Armoured Cables - Table 2/2 1x3x1.5
2x3x1.5
4x3x1.5
8x3x1.5
Stranding mm
Cable
1x3x0.75 2x3x0.75 4x3x0.75 8x3x0.75 12x3x0.75 16x3x0.75 24x3x0.75 7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.53
7/0.53
7/0.53
7/0.53
12x3x1.5 16x3x1.5 24x3x1.5 7/0.53
7/0.53
7/0.53
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.1
1.1
1.1
1.1
1.3
1.4
1.8
1.1
1.1
1.1
1.1
1.3
1.6
1.8
Diameter over Inner Sheath (min/max) mm
7.7/9.3
12.0/14.0
14.0/16.0
18.5/21.5
23.0./26.0
25.0/29.0
31.5/35.5
8.7/10.3
14.0/16.0
16.5/18.5
21.5/24.5
27.0/30.0
30.0/34.0
37.5/41.5 0.4
Diameter of Armour/Braid mm
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.2
0.3
0.3
0.3
0.3
0.3
Thickness of Outer Sheath mm
1.1
1.3
1.4
1.6
1.7
1.8
2
1.1
1.4
1.5
1.7
1.9
2
2.3
Overall Diameter (min/max) mm
10.5/12.5
15.5/17.5
18.0/20.0
23.0/26.0
27.5/30.5
30.0/34.0
37.5/41.5
12.0/14.0
18.0/20.0
20.0/23.0
26.5/29.5
31.5/35.5
35.5/39.5
43.5/48.5
Gland Size
O
A
A
B
C
C2
D
O
A
B
C
C2
C2
D
Weight kg/km
210
420
560
950
1350
1630
2550
300
550
780
1390
1970
2570
3790
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
100
100
100
Inductance/ Resistance – mH/km
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.68
0.68
0.68
0.68
0.68
0.68
0.68
Capacitance – nF/KM
90
90
90
90
90
90
90
110
110
110
110
110
110
110
DC Resistance @ 20°c – Ohms/km
24.8
24.8
24.8
24.8
24.8
24.8
24.8
12.2
12.2
12.2
12.2
12.2
12.2
12.2
Sheath Colour
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/ Blue
Grey/ Blue
Grey/ Blue
Grey/Blue
Grey/Blue
Datasheet Ref: OFS-NK-INS-IS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
Section 4 Offshore Instrumentation Cables to NEK 606 Specification
BFOU FIRE RESISTANT
FPAL Verify
Verified No.10049350
ABS
4
BS6883
Offshore Instrumentation Cables to NEK 606 Specification
BFOU(i) Pairs/Triples Armoured Cables â&#x20AC;&#x201C; Individually Screened:
NEK606
150/250 V Fire Resistant
Applicable Standards IEEE
NEK 606 / IEC 60092-3 IEC 60092-351 IEC 60331 part 3 (Category A) IEC-60092-359
Stranded class 2 or tinned annealed copper conductors to IEC60228
Application IEC
This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.
Conductor Identification Single Pair: Black/ Light Blue Triples: Black/ Light Blue/ Brown New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Annealed Copper Conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Fire Protection
Mica Glass Tape
(3) Insulation
(B) - EPR Complying with IEC60092-351
(4) Individual Screen
Aluminium or Copper Mylar Tape Screen in contact with Tinned Copper drain wire
(5) Bedding:
(F) - Flame Retardant Halogen Free Compound, PETP-tape
(6) Armour:
(O) - Tinned Copper Wire Braid to NVE FEA-M 1238.5, PETP-tape
(7) Outer Sheath:
(U) - SHF2 dual Compound thermo set rubber - IEC60092-359 Type SHF2, Dual rated as being Both halogen free and mud resistant in accordance with NEK606, and meets cold bend and Impact test (-20C) cross sectional area C22.2
Datasheet Ref: OFS-NK-INS-IS-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250 V Fire Resistant
Offshore Instrumentation Cables to NEK 606 Specification
BFOU(i) Pairs/Triples Armoured Cables - Table 1/3 Cable
1x2x0.75
2x2x0.75
4x2x0.75
8x2x0.75
12x2x0.75 16x2x0.75 24x2x0.75
1x2x1.5
2x2x1.5
4x2x1.5
8x2x1.5
12x2x1.5
Stranding mm
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.1
1.1
1.1
1.1
1.3
1.4
1.8
1.1
1.1
1.1
1.1
1.3
Diameter over Inner Sheath (min/max) mm
8.2/9.8
11.5/13.5
13.5/15.5
18.5/21.5
22.0./25.0
25.0/28.0
30.5/34.5
9.0/11.0
13.5/15.5
16.0/18.0
21.5/24.5
25.5/28.5
Diameter of Armour/Braid mm
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Thickness of Outer Sheath mm
1.1
1.3
1.4
1.6
1.7
1.8
2.1
1.1
1.4
1.5
1.7
1.9
Overall Diameter (min/max) mm
11.0/13.0
15.0/17.0
17.5/19.5
23.0/26.0
27.0/30.0
30.0/33.0
36.5/40.5
12.0/14.0
17.5/19.5
20.0/22.0
26.0/29.0
30.0/34.0
Gland Size
O
A
A
B
C
C
C2
O
A
B
C
C2
Weight kg/km
220
390
510
890
1250
1490
2210
250
510
690
1230
1670
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
100
Inductance/ Resistance – mH/km
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.63
0.63
0.63
0.63
0.63
Capacitance – nF/KM
110
110
110
110
110
110
110
125
125
125
125
125
DC Resistance @ 20°c – Ohms/km
24.8
24.8
24.8
24.8
24.8
24.8
24.8
12.2
12.2
12.2
12.2
12.2
Sheath Colour
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/ Blue
Grey/ Blue
Grey/ Blue
BFOU(i) Pairs/Triples Armoured Cables - Table 2/3 Cable
16x2x1.5
24x2x1.5
1x2x2.5
Stranding mm
7/0.53
7/0.53
-
4x2x2.5
1x3x0.75
2x3x0.75
4x3x0.75
8x3x0.75
7/0.37
7/0.37
7/0.37
7/0.37
12x3x0.75 16x3x0.75 24x3x0.75 7/0.37
7/0.37
7/0.37
1x3x1.5 7/0.53 0.8
Insulation Thickness mm
0.8
1
1
1
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.6
1.8
1.1
1.1
1.1
1.1
1.1
1.1
1.3
1.4
1.8
1.1
Diameter over Inner Sheath (min/max) mm
29.5/32.5
35.5/39.5
10.5/12.5
19.0/22.0
8.7/10.3
12.5/14.5
15.5/17.5
20.0/23.0
24.5/27.5
27.0/30.0
34.0/38.0
9.5/11.5 0.2
Diameter of Armour/Braid mm
0.3
0.4
0.2
0.3
0.2
0.3
0.3
0.3
0.3
0.3
0.4
Thickness of Outer Sheath mm
2
2.3
1.2
1.6
1.1
1.4
1.4
1.7
1.8
1.9
2.2
1.2
Overall Diameter (min/max) mm
34.0/38.0
41.5/46.5
13.5/15.5
23.0/26.0
11.5/13.5
16.5/18.5
18.5/21.5
24.5/27.5
29.0/33.0
31.5/35.5
39.5/44.5
12.5/14.5
Gland Size
C2
D
O
B
O
A
B
C
C
C2
D
O
Weight kg/km
2100
3020
330
950
240
440
620
1080
1540
1790
2720
300
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
100
Inductance/ Resistance – mH/km
0.63
0.63
0.59
0.59
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.63
Capacitance – nF/KM
125
125
145
145
110
110
110
110
110
110
110
125
DC Resistance @ 20°c – Ohms/km
12.2
12.2
7.56
7.56
24.8
24.8
24.8
24.8
24.8
24.8
24.8
12.2
Sheath Colour
Grey/ Blue
Grey/ Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Datasheet Ref: OFS-NK-INS-IS-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250 V Fire Resistant
Offshore Instrumentation Cables to NEK 606 Specification
BFOU(i) Pairs/Triples Armoured Cables - Table 3/3 Cable
2x3x1.5
4x3x1.5
8x3x1.5
12x3x1.5
16x3x1.5
24x3x1.5
Stranding mm
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53 0.8
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.1
1.1
1.1
1.5
1.6
2
Diameter over Inner Sheath (min/max) mm
14.5/16.5
17.5/19.5
23.0/26.0
28.5/32.5
32.0/36.0
39.5/44.5
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.4
0.4
Thickness of Outer Sheath mm
1.5
1.6
1.8
2
2.2
2.5
Overall Diameter (min/max) mm
18.5/20.5
21.5/24.5
27.5/30.5
33.5/37.5
37.5/42.5
46.0/51.0
Gland Size
A
B
C
C2
D
D 3950
Weight kg/km
570
910
1440
2150
2700
Bend Radius - xOD
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
Inductance/ Resistance – mH/km
0.63
0.63
0.63
0.63
0.63
0.63
Capacitance – nF/KM
125
125
125
125
125
125
DC Resistance @ 20°c – Ohms/km
12.2
12.2
12.2
12.2
12.2
12.2
Sheath Colour
Grey/ Blue
Grey/ Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/ Blue
Datasheet Ref: OFS-NK-INS-IS-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883
Offshore Instrumentation Cables to NEK 606 Specification NEK606
150/250 V Fire Resistant
BFOU(c) Pairs/Triples Armoured Cables â&#x20AC;&#x201C; Collectively Screened:
Applicable Standards
IEEE
NEK 606 / IEC 60092-3 IEC 60092-351 IEC 60331 part 3 (Category A) IEC-60092-359 Stranded class 2 or tinned annealed copper conductors to IEC60228
Application IEC
This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.
Conductor Identification Single Pair: Black/ Light Blue Triples: Black/ Light Blue/ Brown New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Annealed Copper Conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Fire Protection
Mica Glass Tape
(3) Insulation:
(B) - EPR Complying with IEC60092-351
(4) Collective Screen
Aluminium or Copper Mylar Tape Screen in contact with Tinned Copper drain wire
(5) Bedding:
(F) - Flame Retardant Halogen Free Compound, PETP-tape
(6) Armour:
(O) - Tinned Copper Wire Braid to NVE FEA-M 1238.5, PETP-tape
(7) Outer Sheath:
(U) - SHF2 dual Compound thermo set rubber - IEC60092-359 Type SHF2, Dual rated as being Both halogen free and mud resistant in accordance with NEK606, and meets cold bend and Impact test (-20C) cross sectional area C22.2
Datasheet Ref: OFS-NK-INS-CS-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250 V Fire Resistant
Offshore Instrumentation Cables to NEK 606 Specification
BFOU(c) Pairs/Triples Armoured Cables - Table 1/3 Cable
2x2x0.75
4x2x0.75
8x2x0.75
12x2x0.75 16x2x0.75 24x2x0.75
2x2x1.5
4x2x1.5
8x2x1.5
12x2x1.5
16x2x1.5
24x2x1.5 7/0.53
Stranding mm
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.1
1.1
1.1
1.3
1.4
1.8
1.1
1.1
1.1
1.3
1.4
1.8
Diameter over Inner Sheath (min/max) mm
11.5/13.5
13.5/15.5
22.5/25.5
21.0/24.0
22.5./25.5
28.0/31.0
13.0/15.0
15.0/17.0
21.0/24.0
24.0/27.0
26.0/29.0
32.0/36.0
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Thickness of Outer Sheath mm
1.3
1.4
1.5
1.6
1.7
2
1.4
1.4
1.7
1.8
1.9
2.2
Overall Diameter (min/max) mm
15.0/17.0
17.0/19.0
22.5/25.5
25.5/28.5
27.5/30.5
33.0/37.0
16.5/18.5
18.5/21.5
25.0/26.0
28.0/32.0
30.5/34.5
37.5/42.5
Gland Size
A
A
B
C
C
C2
A
B
B
C
C2
D
Weight kg/km
350
460
780
1040
1210
1730
450
610
1030
1390
1670
2440
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
100
Inductance/ Resistance – mH/km
0.67
0.67
0.67
0.67
0.67
0.67
0.63
0.63
0.63
0.63
0.63
0.63
Capacitance – nF/KM
100
100
100
100
100
100
110
110
110
110
110
110
DC Resistance @ 20°c – Ohms/km
24.8
24.8
24.8
24.8
24.8
4.8
12.2
12.2
12.2
12.2
12.2
12.2
Sheath Colour
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/ Blue
Grey/ Blue
Grey/ Blue
BFOU(c) Pairs/Triples Armoured Cables - Table 2/3 Cable
2x2x2.5
4x2x2.5
8x2x2.5
16x2x2.5
24x2x2.5
2x3x0.75
4x3x0.75
8x3x0.75
12x3x0.75 16x3x0.75 24x3x0.75
Stranding mm
-
-
-
-
-
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
Insulation Thickness mm
1
1
1
1
1
0.8
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.1
1.1
1.1
1.6
2
1.1
1.1
1.1
1.3
1.4
1.8
Diameter over Inner Sheath (min/max) mm
15.5/17.5
18.0/21.0
25.0/28.0
31.5/35.5
39.0/44.0
13.0/15.0
15.5/17.5
20.0./23.0
24.0/27.0
26.0/29.0
32.0/36.0
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.4
Thickness of Outer Sheath mm
1.4
1.5
1.8
2.1
2.4
1.3
1.4
1.6
1.8
1.9
2.1
Overall Diameter (min/max) mm
19.5/21.5
22.0/25.0
29.0/33.0
37.5/41.5
45.5/50.5
17.0/19.0
19.0/22.0
24.5/27.5
28.5/32.5
30.5/34.5
37.5/41.5
Gland Size
B
B
C
D
D
A
B
C
C
C2
D 2340
Weight kg/km
210
420
560
2440
3540
470
610
1020
1380
1590
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
100
100
100
100
100
Inductance/ Resistance – mH/km
0.59
0.59
0.59
0.59
0.59
0.67
0.67
0.67
0.67
0.67
0.67
Capacitance – nF/KM
125
125
125
125
125
100
100
100
100
100
100
DC Resistance @ 20°c – Ohms/km
7.56
7.56
7.56
7.56
7.56
24.8
24.8
24.8
24.8
24.8
24.8
Sheath Colour
Grey/ Blue
Grey/ Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Grey/Blue
Datasheet Ref: OFS-NK-INS-CS-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250 V Fire Resistant
Offshore Instrumentation Cables to NEK 606 Specification
BFOU(c) Pairs/Triples Armoured Cables - Table 3/3 Cable
2x3x1.5
4x3x1.5
8x3x1.5
12x3x1.5
16x3x1.5
24x3x1.5
Stranding mm
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53 0.8
Insulation Thickness mm
0.8
0.8
0.8
0.8
0.8
Thickness of Inner Sheath mm
1.1
1.1
1.1
1.3
1.6
2
Diameter over Inner Sheath (min/max) mm
15.0/17.0
17.5/19.5
23.0/26.0
24.0/27.0
26.0/29.0
32.0/36.0
Diameter of Armour/Braid mm
0.3
0.3
0.3
0.3
0.4
0.4
Thickness of Outer Sheath mm
1.4
1.5
1.8
1.9
2.1
2.4
Overall Diameter (min/max) mm
18.5/21.5
21.0/24.0
28.0/31.0
32.5/36.5
35.5/39.5
43.5/48.5
Gland Size
B
B
C
C2
C2
D 3410
Weight kg/km
600
790
1350
1910
2330
Bend Radius - xOD
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
Short Circuit Rating, 1second – 250°c - A
100
100
100
100
100
100
Inductance/ Resistance – mH/km
0.63
0.63
0.63
0.63
0.63
0.63
Capacitance – nF/KM
110
110
110
110
110
110
DC Resistance @ 20°c – Ohms/km
12.2
12.2
12.2
12.2
12.2
12.2
Sheath Colour
Grey/Blue
Grey/ Blue
Grey/ Blue
Grey/Blue
Grey/Blue
Grey/ Blue
Datasheet Ref: OFS-NK-INS-CS-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
Section 5 Offshore Power & Control Cables to NEK 606 Specification
RFOU FLAME RETARDANT
FPAL Verify
Verified No.10049350
ABS
5
BS6883 RFOU Single and Multicore Armoured Cables:
NEK606
Offshore Power & Control Cables to NEK606 Specification Applicable Standards NEK 606 / IEC 60092-3 IEC 60092-351 IEC 60332 part 3 (Category A) IEC-60092-359 Stranded class 2 or tinned annealed copper conductors to IEC60228
IEEE
600/1000V Flame Retardant
Application
IEC
This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially where life may be endangered by smoke and noxious fumes, and where sensitive equipnment may be damaged by acid forming gases.
Conductor Identification
One core: Black Two cores: Blue- Brown Two cores+ earth Blue - Brown - Yellow/Green Three Cores: Brown - Black - Grey Three Cores + earth Brown - Black - Grey - Yellow/Green Four Cores: Blue - Brown - Black - Grey Four Cores + earth Blue - Brown - Black - Grey - Yellow/Green Five Cores Blue - Brown - Black - Grey - Black Above 5-cores : Black numbers on white base. New harmonised core colours or project specified colours can be supplied upon special request
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Annealed Copper Conductor to IEC60228
Fire Protection
None
(2) Insulation:
(R) - EPR Complying with IEC60092-351
(3) Bedding:
(F) - Flame Retardant Halogen Free Compound, PETP-tape
(4) Armour:
(O) - Tinned Copper Wire Braid to NVE FEA-M 1238.5, PETP-tape
(5) Outer Sheath:
(U) - SHF2 dual Compound thermoset rubber - IEC60092-359 Type SHF2, Dual rated as being Both halogen free and mud resistant in accordance with NEK606, and meets cold bend and Impact test (-20C) cross sectional area C22.2.
Datasheet Ref: OFS-NK-PC-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000V Flame Retardant
Offshore Power & Control Cables to NEK606 Specification
RFOU Single/Multicore Armoured Cables - Table 1/4 Cable
1 x16
1 x 25
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185
1 x 240
1 x 300
2 x 1.5
2 x2.5
2x4 7/0.85
Stranding mm
7/1.70
19/1.35
19/1.53
19/1.78
19/2.14
37/1.78
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
7/0.53
7/0.67
Insulation Thickness mm
1
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2
2.2
2.4
1
1
1
Thickness of Inner Sheath mm
1.1
1.1
1.1
1.1
1.1
1.1
1.2
1.2
1.2
1.2
1.2
1.1
1.1
1.1
Diameter over Inner Sheath (min/max) mm
9.0/11.0
10.5/12.5
12.0/14.0
14.0/16.0
16.0/18.0
18.0/20.0
19.0/22.0
21.5/24.5
23.5/26.5
26.5/29.5
28.5/32.5
9.0/11.0
9.5/11.5
11.0/13.0
Diameter of Armour/Braid mm
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.2
0.2
0.3
Thickness of Outer Sheath mm
1.2
1.2
1.3
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
1.2
1.2
1.3
Overall Diameter (min/max) mm
12.5/14.5
14.0/16.0
15.5/17.5
18.0/20.0
19.0/22.0
21.5/24.5
23.5/26.5
25.5/28.5
28.0/31.0
30.5/34.5
34.0/38.0
12.0/14.0
13.0/15.0
14.5/16.5
Gland Size
O
O
A
A
B
B
C
C
C
C2
C2
O
O
A
Weight kg/km
350
470
640
820
1060
1360
1680
2010
2430
3090
3790
260
300
400
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
85 560
Short Circuit Rating, 1second ampere
2240
3500
4900
7000
9800
13300
16800
21000
25900
33600
42000
210
350
Current Rating at 45°C - ampere
90
120
145
180
225
275
320
365
415
490
560
17
24
32
DC Resistance max @ 20°c - Ώ/km
1.16
0.734
0.529
0.391
0.27
0.195
0.154
0.126
0.1
0.076
0.061
12.2
7.56
4.7
DC Resistance max @ 50Hz - Ώ/km
0.116
0.112
0.106
0.103
0.1
0.097
0.094
0.092
0.091
0.09
0.089
0.11
0.103
0.096
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
RFOU Single/Multicore Armoured Cables - Table 2/4 Cable
2x6
2 x 10
2 x 16
3 x 1.5
3 x 2.5
3x4
3x6
3 x 10
3 x 16
3 x 25
3 x 35
3 x 50
3 x 70
3 x95
Stranding mm
7/1.04
7/1.35
7/1.70
7/0.53
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
19/1.35
19/1.53
19/1.78
19/2.14
37/1.78 1.6
Insulation Thickness mm
1
1
1
1
1
1
1
1
1
1.2
1.2
1.4
1.4
Thickness of Inner Sheath mm
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.2
1.2
1.2
1.4
1.4
Diameter over Inner Sheath (min/max) mm
12.0/14.0
14.0/16.0
16.0/18.0
9.5/11.5
10.5/12.5
11.5/13.5
13.0/15.0
15.0/17.0
17.0/19.0
20.5/23.5
23.0/26.0
27.5/30.5
31.0/35.0
35.5/39.5 0.5
Diameter of Armour/Braid mm
0.3
0.3
0.4
0.2
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.4
0.5
Thickness of Outer Sheath mm
1.3
1.4
1.5
1.2
1.3
1.3
1.4
1.4
1.5
1.6
1.7
1.9
2
2.2
Overall Diameter (min/max) mm
15.5/17.5
17.5/19.5
20.0/23.0
12.5/14.5
14.0/16.0
15.0/17.0
16.5/18.5
18.5/20.5
21.0./24.0
25.0/28.0
27.5/30.5
32.0/36.0
37.0/41.0
41.0/46.0
Gland Size
A
A
B
O
O
A
A
A
B
C
C
C2
C2
D
Weight kg/km
490
640
910
290
370
460
570
740
1070
1520
1880
2630
3540
4660
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
85 13300
Short Circuit Rating, 1second ampere
840
1400
2240
210
350
560
840
1400
2240
3500
4900
7000
9800
Current Rating at 45°C - ampere
41
57
77
14
20
27
34
47
63
84
100
125
160
195
DC Resistance max @ 20°c - Ώ/km
3.11
1.84
1.16
12.2
7.56
4.7
3.11
1.84
1.16
0.734
0.529
0.391
0.27
0.195
DC Resistance max @ 50Hz - Ώ/km
0.09
0.084
0.08
0.11
0.103
0.096
0.09
0.08
0.079
0.076
0.076
0.076
0.075
0.073
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Datasheet Ref: OFS-NK-PC-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000V Flame Retardant
Offshore Power & Control Cables to NEK606 Specification
RFOU Single/Multicore Armoured Cables - Table 3/4 Cable
3 x 120
3 x 150
3 x 185
4 x 1.5
4 x 2.5
4x4
4x6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95
Stranding mm
37/2.03
-
-
7/0.53
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
19/1.35
19/1.53
19/1.78
19/2.14
37/1.78
Insulation Thickness mm
1.6
1.8
2
1
1
1
1
1
1
1.2
1.2
1.4
1.4
1.6
Thickness of Inner Sheath mm
1.4
1.6
1.6
1.1
1.1
1.1
1.1
1.1
1.2
1.2
1.2
1.4
1.4
1.4
Diameter over Inner Sheath (min/max) mm
38.5/43.5
42.5/47.5
49.5/54.5
10.5/12.5
11.5/13.5
12.5/14.5
14.0/16.0
16.5/18.5
18.5/21.5
22.5/25.5
26.0/29.0
30.0/34.0
34.5/38.5
39.0/44.0 0.5
Diameter of Armour/Braid mm
0.6
0.6
0.5
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.4
0.5
Thickness of Outer Sheath mm
2.3
2.5
2.7
1.3
1.3
1.4
1.4
1.5
1.6
1.7
1.8
2
2.2
2.4
Overall Diameter (min/max) mm
45.5/50.5
51.0/57.0
59.0/66.0
14.0/16.0
15.0/17.0
16.5/18.5
18.0/20.0
20.0/23.0
23.5/26.5
27.5./30.5
30.0/34.0
35.5/39.5
40.5/45.5
45.5/50.5
Gland Size
D
E
F
O
A
A
A
B
C
C
C2
C2
D
D
Weight kg/km
5740
7450
25900
210
350
560
840
1400
2240
3500
4900
7000
9800
13300
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second ampere
16800
21000
25900
210
350
560
840
1400
2240
3500
4900
7000
9800
13300
Current Rating at 45°C - ampere
225
255
290
14
20
27
34
47
63
84
100
125
160
195
DC Resistance max @ 20°c - Ώ/km
0.154
0.126
0.1
12.2
7.56
4.7
3.11
1.84
1.16
0.734
0.529
0.391
0.27
0.195
DC Resistance max @ 50Hz - Ώ/km
0.072
0.072
0.072
0.11
0.103
0.096
0.09
0.084
0.08
0.079
0.076
0.076
0.075
0.073
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
RFOU Single/Multicore Armoured Cables - Table 4/4 Cable
4x185
5 x 1.5
7 x 1.5
7 x 2.5
12 x 1.5
12 x 2.5
19 x 1.5
19 x 2.5
27 x 1.5
27 x 2.5
37 x 1.5
37 x 2.5
Stranding mm
-
-
7/0.53
7/0.67
7/0.53
7/0.67
7/0.53
7/0.67
7/0.53
7/0.67
7/0.53
7/0.67
Insulation Thickness mm
2
1
1
1
1
1
1
1
1
1
1
1
Thickness of Inner Sheath mm
1.6
1.1
1.1
1.1
1.1
1.2
1.2
1.2
1.2
1.2
1.2
-
Diameter over Inner Sheath (min/max) mm
52.5/57.5
11.5/13.5
12.5/14.5
13.5/15.5
17.0/19.0
18.5/20.5
19.5/22.5
21.5/24.5
23.5/26.5
26.0/29.0
26.5/29.5
29.5/33.5 -
Diameter of Armour/Braid mm
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Thickness of Outer Sheath mm
2.8
1.3
1.3
1.4
1.5
1.6
1.6
1.7
1.8
1.9
1.9
-
Overall Diameter (min/max) mm
63.0/70.0
15.0/17.0
16.0/18.0
17.5/19.5
20.5/23.5
22.5/25.5
24.0/27.0
26.0/29.0
28.0/32.0
30.5/34.5
31.0./35.0
34.5/38.5
Gland Size
F
A
A
O
B
B
C
C
C
C2
C2
C2
Weight kg/km
25900
210
210
610
720
910
990
1260
1320
1680
1670
2190
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second ampere
25900
210
210
350
210
350
210
350
210
350
210
350
Current Rating at 45°C - ampere
290
12
10
15
9
12
8
11
6.5
9
6
8
0.1
12.2
12.2
7.56
12.2
7.56
12.2
7.56
12.2
7.56
12.2
7.56
DC Resistance max @ 20°c Ώ/km DC Resistance max @ 50Hz Ώ/km Sheath Colour
0.072
0.11
0.11
0.103
0.11
0.103
0.11
0.103
0.11
0.103
0.11
0.103
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Datasheet Ref: OFS-NK-PC-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
Section 5 Offshore Power & Control Cables to NEK 606 Specification
BFOU FIRE RESISTANT
FPAL Verify
Verified No.10049350
ABS
5
BS6883
Offshore Power & Control Cables to NEK 606 Specification
NEK606
600/1000 V Fire Resistant
BFOU Single and Multicore armoured cables:
Applicable Standards
IEEE
NEK 606 / IEC 60092-3 IEC 60092-351 IEC 60331 part 3 (Category A) IEC 60092-359 Stranded class 2 or tinned annealed copper conductors to IEC60228
Application IEC
This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.
Conductor Identification One core: Black Two cores: Blue – Brown Two cores + earth Blue – Brown – Yellow/green Three cores: Brown - Black – Grey Three cores + earth Brown - Black – Grey – Yellow/green Four cores: Blue - Brown - Black– Grey Four cores + earth Blue - Brown - Black– Grey – Yellow/green Five cores Blue - Brown - Black– Grey - Black Above 5-cores : Black numbers on white base.
Note: picture is for illustration purposes only
New harmonised core colours or project specified colours can be supplied upon special request
Construction
Specifications
(1) Conductor:
Tinned Stranded Annealed Copper Conductor to IEC60228
(2) Fire Protection
Mica Glass Tape
(3) Insulation:
(B) - EPR Complying with IEC60092-351
(4) Bedding:
(F) - Flame Retardant Halogen Free Compound, PETP-tape
(5) Armour:
(O) - Tinned Copper Wire Braid to NVE FEA-M 1238.5, PETP-tape
(6) Outer Sheath:
(U) - SHF2 dual Compound thermo set rubber - IEC60092-359 Type SHF2, Dual rated as being Both halogen free and mud resistant in accordance with NEK606, and meets cold bend and Impact test (-20C) cross sectional area C22.2
Datasheet Ref: OFS-NK-PC-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com
FPAL Verify
Verified
No.10049350
ABS
600/1000 V Fire Resistant
Offshore Power & Control Cables to NEK 606 Specification
BFOU Single/Multicore Armoured Cables - Table 1/4 Cable
1 x16
1 x 25
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185
1 x 240
1 x 300
2 x 1.5
2 x2.5
2x4
Stranding mm
7/1.70
19/1.35
19/1.53
19/1.78
19/2.14
37/1.78
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
7/0.53
7/0.67
7/0.85
Insulation Thickness mm
1
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2
2.2
2.4
1
1
1
Thickness of Inner Sheath mm
1.1
1.1
-
1.1
1.1
1.1
1.2
1.2
1.2
1.2
1.2
1.1
1.1
1.1
Diameter over Inner Sheath (min/max) mm
9.5/11.5
11.0/13.0
12.5/14.5
14.5/16.5
16.0/18.0
18.0/20.0
19.5/22.5
22.0/25.0
24.0/27.0
27.0/30.0
29.0/33.0
9.5/11.5
10.5/12.5
11.5/13.5
Diameter of Armour/Braid mm
0.2
0.3
-
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.2
0.3
0.3
Thickness of Outer Sheath mm
1.2
1.3
-
1.4
1.4
1.5
1.6
1.7
1.7
1.8
1.9
1.2
1.3
1.3
Overall Diameter (min/max) mm
12.5/14.5
14.0/16.0
16.0/18.0
18.0/20.0
19.5/22.5
22.0/25.0
24.0/27.0
26.0/29.0
28.5/31.5
31.0/35.0
34.5/38.5
12.5/14.5
13.5/15.5
15.0/17.0
Gland Size
O
O
A
A
B
B
C
C
C
C2
C2
O
O
A
Weight kg/km
360
480
650
830
1070
1380
1700
2030
2470
3130
3820
280
320
420
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second ampere
2240
3500
4900
7000
9800
13300
16800
21000
25900
33600
42000
210
350
560
90
120
145
180
225
275
320
365
415
490
560
17
24
32
1.16
0.734
0.529
0.391
0.27
0.195
0.154
0.126
0.1
0.0762
0.0607
12.2
7.56
4.7
DC Resistance max @ 50Hz - Ώ/km
0.12
0.113
0.107
0.104
0.101
0.098
0.094
0.094
0.091
0.091
0.089
0.015
0.107
0.1
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Current Rating at
45°C - ampere
DC Resistance max @ 20°c - Ώ/km
BFOU Single/Multicore Armoured Cables - Table 2/4 Cable
2x6
2 x 10
2 x 16
3 x 1.5
3 x 2.5
3x4
3x6
3 x 10
3 x 16
3 x 25
3 x 35
3 x 50
3 x 70
3 x95
Stranding mm
7/1.04
7/1.35
7/1.70
7/0.53
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
19/1.35
19/1.53
19/1.78
19/2.14
37/1.78 1.6
Insulation Thickness mm
1
1
1
1
1
1
1
1
1
1.2
1.2
1.4
1.4
Thickness of Inner Sheath mm
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.2
1.2
1.2
1.4
1.4
Diameter over Inner Sheath (min/max) mm
12.5/14.5
14.5/16.5
16.5/18.5
10.0/12.0
11.0/13.0
12.5/14.5
13.5/15.5
15.5/17.5
18.0/20.0
21.0/24.0
24.0/27.0
28.0/31.0
32.5/36.5
36.0/40.0 0.6
Diameter of Armour/Braid mm
0.3
0.3
0.5
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.4
0.5
Thickness of Outer Sheath mm
1.4
1.4
1.5
1.3
1.3
1.3
1.4
1.5
1.5
1.7
1.8
1.9
2
2.2
Overall Diameter (min/max) mm
16.5/18.5
18.5/20.5
21.0/24.0
13.5/15.5
14.5/16.5
16.0/18.0
17.5/19.5
19.5/21.5
22.0./25.0
25.5/28.5
28.0/32.0
32.5/36.5
38.0/43.0
42.0/47.0
Gland Size
A
A
B
O
A
A
A
B
B
C
C
C2
D
D
Weight kg/km
510
680
960
310
400
500
590
780
1130
1510
1930
2640
3630
4720
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second ampere
840
1400
2240
210
350
560
840
1400
2240
3500
4900
7000
9800
13300
41
57
77
14
20
27
34
47
63
84
100
125
160
195
DC Resistance max @ 20°c - Ώ/km
3.11
1.84
1.16
12.2
7.56
4.7
3.11
1.84
1.16
0.734
0.529
0.391
0.27
0.195
DC Resistance max @ 90°c - Ώ/km
0.094
0.088
0.082
0.015
0.107
0.1
0.094
0.088
0.082
0.081
0.078
0.078
0.077
0.075
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Current Rating at
45°C - ampere
Datasheet Ref: OFS-NK-PC-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000 V Fire Resistant
Offshore Power & Control Cables to NEK 606 Specification
BFOU Single/Multicore Armoured Cables - Table 3/4 Cable
3 x 120
3 x 150
3 x 185
4 x 1.5
4 x 2.5
4x4
4x6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95
Stranding mm
37/2.03
-
-
7/0.53
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
19/1.35
19/1.53
19/1.78
19/2.14
37/1.78
Insulation Thickness mm
1.6
1.8
2
1
1
1
1
1
1
1.2
1.2
1.4
1.4
1.6
Thickness of Inner Sheath mm
1.4
1.6
1.6
1.1
1.1
1.1
1.1
1.1
1.2
1.2
1.2
1.4
1.4
1.4
Diameter over Inner Sheath (min/max) mm
38.5/43.5
42.5/47.5
49.5/54.5
10.5/12.5
11.5/13.5
12.5/14.5
14.0/16.0
16.5/18.5
18.5/21.5
22.5/25.5
26.0/29.0
30.0/34.0
34.5/38.5
39.0/44.0 0.5
Diameter of Armour/Braid mm
0.6
0.6
0.5
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.4
0.5
Thickness of Outer Sheath mm
2.3
2.5
2.7
1.3
1.3
1.4
1.4
1.5
1.6
1.7
1.8
2
2.2
2.4
Overall Diameter (min/max) mm
45.5/50.5
51.0/57.0
59.0/66.0
14.0/16.0
15.0/17.0
16.5/18.5
18.0/20.0
20.0/23.0
23.5/26.5
27.5./30.5
30.0/34.0
35.5/39.5
40.5/45.5
45.5/50.5
Gland Size
D
E
F
O
A
A
A
B
C
C
C2
C2
D
D
Weight kg/km
5740
7450
25900
210
350
560
840
1400
2240
3500
4900
7000
9800
13300
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
85 13300
Short Circuit Rating, 1second ampere
16800
21000
25900
210
350
560
840
1400
2240
3500
4900
7000
9800
Current Rating at 45°C - ampere
225
255
290
14
20
27
34
47
63
84
100
125
160
195
DC Resistance max @ 20°c - Ώ/km
0.154
0.126
0.1
12.2
7.56
4.7
3.11
1.84
1.16
0.734
0.529
0.391
0.27
0.195
DC Resistance max @ 50Hz - Ώ/km
0.072
0.072
0.072
0.11
0.103
0.096
0.09
0.084
0.08
0.079
0.076
0.076
0.075
0.073
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
BFOU Single/Multicore Armoured Cables - Table 4/4 Cable
4x120
4x185
5 x 1.5
7 x 1.5
7 x 2.5
12 x 1.5
12 x 2.5
19 x 1.5
19 x 2.5
27 x 1.5
27 x 2.5
37 x 1.5
37 x 2.5 7/0.67
Stranding mm
37/2.03
-
-
7/0.53
7/0.67
7/0.53
7/0.67
7/0.53
7/0.67
7/0.53
7/0.67
7/0.53
Insulation Thickness mm
1.6
2.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Thickness of Inner Sheath mm
1.6
-
1.1
1.1
1.1
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
Diameter over Inner Sheath (min/max) mm
43.5/48.5
55.0/61.0
12.0/14.0
13.5/15.5
14.5/16.5
18.0/20.0
19.5/22.5
21.0/24.0
23.0/26.0
25.5/28.5
28.0/31.0
28.5/32.5
31.5/35.5
Diameter of Armour/Braid mm
0.6
-
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
Thickness of Outer Sheath mm
2.5
-
1.4
1.4
1.4
1.6
1.6
1.7
1.8
1.9
2.0
2.0
2.2
Overall Diameter (min/max) mm
50.5/56.5
65.0/72.0
16.0/18.0
17.0/19.0
18.5/20.5
21.5/24.5
23.5/26.5
25.5/28.5
27.5/30.5
29.5/33.5
32.5/36.5
33.5./37.5
37.0/41.0
Gland Size
E
F
A
A
A
B
C
C
C
C2
C2
C2
C2
Weight kg/km
7180
12000
460
520
650
780
980
1080
1350
1440
1810
1840
2370
Bend Radius - xOD
8
8
8
8
8
8
8
8
8
8
8
8
8
Conductor Temperature - °C
85
85
85
85
85
85
85
85
85
85
85
85
85
Short Circuit Rating, 1second ampere
16800
25900
210
210
350
210
350
210
350
210
350
210
350
Current Rating at 45°C - ampere
225
290
12
10
15
9
12
8
11
6.5
9
6
8
DC Resistance max @ 20°c - Ώ/km
0.1540
0.1000
12.2000
12.2000
7.5600
12.2000
7.56
12.2000
7.5600
12.2000
7.5600
12.2000
7.5600
DC Resistance max @ 90°c - Ώ/km
0.073
0.073
0.015
0.015
0.107
0.015
0.107
0.015
0.107
0.015
0.107
0.015
0.107
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Datasheet Ref: OFS-NK-PC-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
Section 6 Medium Voltage Power Cables to NEK 606 Specification
RFOU FLAME RETARDANT
FPAL Verify
Verified No.10049350
ABS
6
BS6883
Medium Voltage Power Cables to NEK606 Specification NEK606
3.6/6kV Flame Retardant RFOU Power Cables, Single Core, Armoured Cables:
Applicable Standards
IEC
IEEE
NEK 606 IEC 60092-354 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228
Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009
Conductor Identification One core: Black New harmonised core colours or project specified colours can be supplied upon special request. Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Conductor Screen:
Semi-conductive tape or extruded semi-conductive compound.
(3) Insulation:
EP-Rubber
(4) Insulation Screen:
Semi-conductive tape or extruded semi-conductive compound.
(5) Metallic Screen:
Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)
(6) Bedding:
Flame retardant halogen free compound. PET Tape
(7) Armour:
Tinned copper wire braid. PET Tape
(8) Outer Sheath
SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour
Datasheet Ref: OFS-NK-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
3.6/6kV Flame Retardant
Medium Voltage Power Cables to NEK606 Specification
RFOU Single Core Armoured Cables Conductor No. of Cores
Nominal Area
Strand
Overall diameter Dia.
Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering
Conductor Resistance (at 20ºC) (Max.)
Insulation Resistance (at 20ºC) (Min.)
Test Voltage
Current Carrying Capacity (Max.) (at 45ºC)
Cable Weight
kg/km
No.
mm²
NO./
mm
mm
mm
mm
mm
mm
mm
mm
±mm
Ω / km
MΏ-km
V/5min.
A
1
25
7/
2.14
6.42
2.5
1.0
18.0
0.3
1.6
23.3
1.4
0.734
920
12.5
121
990
1
35
7/
2.52
7.56
2.5
1.0
19.2
0.3
1.6
24.5
1.5
0.529
810
12.5
149
1,140
1
50
19 /
1.78
8.90
2.5
1.0
20.5
0.3
1.7
26.0
1.5
0.391
710
12.5
186
1,330
1
70
19 /
2.14
10.70
2.5
1.0
22.3
0.3
1.8
28.0
1.6
0.270
610
12.5
230
1,620
1
95
19 /
2.52
12.60
2.5
1.0
24.2
0.3
1.8
29.9
1.7
0.195
530
12.5
278
1,960
1
120
37 /
2.03
14.21
2.5
1.0
25.8
0.3
1.9
31.7
1.8
0.154
480
12.5
322
2,280
1
150
37 /
2.25
15.75
2.5
1.2
27.8
0.3
2.0
33.9
1.9
0.126
440
12.5
370
2,660
1
185
37 /
2.52
17.64
2.5
1.2
29.6
0.3
2.0
35.7
1.9
0.100
400
12.5
422
3,090
1
240
61 /
2.25
20.25
2.6
1.2
32.5
0.4
2.2
39.5
2.1
0.0762
360
12.5
496
3,930
1
300
61 /
2.52
22.68
2.8
1.2
35.3
0.4
2.3
42.5
2.2
0.0607
350
12.5
571
4,690
0
Datasheet Ref: OFS-NK-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 NEK606
Medium Voltage Power Cables to NEK606 Specification
RFOU Power Cables, Multi Core, Armoured Cables:
Applicable Standards IEEE
NEK 606 IEC 60092-354 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228
Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009
IEC
3.6/6kV Flame Retardant
Conductor Identification The individual cores shall be identified by the coloured semi-conducting tape or coloured ribbon tape run longitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows: 3 Cores: Off-White (grey), Black and Red New harmonised core colours or project specified colours can be supplied upon special request.
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Conductor Screen:
Semi-conductive tape or extruded semi-conductive compound.
(3) Insulation:
EP-Rubber
(4) Insulation Screen:
Semi-conductive tape or extruded semi-conductive compound.
(5) Metallic Screen:
Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)
(6) Bedding:
Flame retardant halogen free compound. PET Tape
(7) Armour:
Tinned copper wire braid. PET Tape
(8) Outer Sheath
SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour
Datasheet Ref: OFS-NK-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
3.6/6kV Flame Retardant
Medium Voltage Power Cables to NEK606 Specification
RFOU Multi Core Armoured Cables Conductor No. of Cores
Nominal Area
Strand
Overall diameter Dia.
Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering
Conductor Resistance (at 20ºC) (Max.)
Insulation Resistance (at 20ºC) (Min.)
Test Voltage
Current Carrying Capacity (Max.) (at 45ºC)
Cable Weight
No.
mm²
NO./
mm
mm
mm
mm
mm
mm
mm
mm
±mm
Ω / km
MΏ-km
V/5min.
A
kg/km
3
25
7/
2.14
6.42
2.5
1.2
36.8
0.4
2.4
44.2
2.3
0.734
920
12.5
85
3,300
3
35
7/
2.52
7.56
2.5
1.4
39.8
0.4
2.5
47.4
2.4
0.529
810
12.5
105
3,890
3
50
19 /
1.78
8.90
2.5
1.4
42.6
0.4
2.6
50.4
2.5
0.391
710
12.5
130
4,540
3
70
19 /
2.14
10.70
2.5
1.4
46.4
0.4
2.7
54.4
2.7
0.270
610
12.5
161
5,530
3
95
19 /
2.52
12.60
2.5
1.6
50.9
0.4
2.9
59.3
2.9
0.195
530
12.5
195
6,810
3
120
37 /
2.03
14.21
2.5
1.6
54.4
0.4
3.1
63.2
3.0
0.154
480
12.5
225
7,960
3
150
37 /
2.25
15.75
2.5
1.6
57.8
0.4
3.2
66.8
3.2
0.126
440
12.5
258
9,130
3
185
37 /
2.52
17.64
2.5
1.6
61.7
0.4
3.4
71.1
3.3
0.100
400
12.5
295
10,700
0
Datasheet Ref: OFS-NK-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883
Medium Voltage Power Cables to NEK606 Specification NEK606
6/10kV Flame Retardant RFOU Power Cables, Single Core, Armoured Cables:
Applicable Standards
IEC
IEEE
NEK 606 IEC 60092-354 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228
Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009
Conductor Identification One core: Black New harmonised core colours or project specified colours can be supplied upon special request. Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Conductor Screen:
Semi-conductive tape or extruded semi-conductive compound.
(3) Insulation:
EP-Rubber
(4) Insulation Screen:
Semi-conductive tape or extruded semi-conductive compound.
(5) Metallic Screen:
Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)
(6) Bedding:
Flame retardant halogen free compound. PET Tape
(7) Armour:
Tinned copper wire braid. PET Tape
(8) Outer Sheath
SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour
Datasheet Ref: OFS-NK-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
6/10kV Flame Retardant
Medium Voltage Power Cables to NEK606 Specification
RFOU Single Core Armoured Cables Conductor No. of Cores
Nominal Area
Strand
Overall diameter Dia.
Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering
Conductor Resistance (at 20ºC) (Max.)
Insulation Resistance (at 20ºC) (Min.)
Test Voltage
Current Carrying Capacity (Max.) (at 45ºC)
Cable Weight
No.
mm²
NO./
mm
mm
mm
mm
mm
mm
mm
mm
±mm
Ω / km
MΏ-km
V/5min.
A
kg/km
1
25
7/
2.14
6.42
3.4
1.0
19.8
0.3
1.7
25.3
1.5
0.734
1,150
21
121
1,120
1
35
7/
2.52
7.56
3.4
1.0
21.0
0.3
1.7
26.5
1.6
0.529
1,020
21
149
1,270
1
50
19 /
1.78
8.90
3.4
1.0
22.3
0.3
1.8
28.0
1.6
0.391
900
21
186
1,470
1
70
19 /
2.14
10.70
3.4
1.0
24.1
0.3
1.8
29.8
1.7
0.270
780
21
230
1,760
1
95
19 /
2.52
12.60
3.4
1.0
26.0
0.3
1.9
31.9
1.8
0.195
690
21
278
2,110
1
120
37 /
2.03
14.21
3.4
1.2
28.0
0.3
2.0
34.1
1.9
0.154
620
21
322
2,480
1
150
37 /
2.25
15.75
3.4
1.2
29.6
0.3
2.0
35.7
1.9
0.126
570
21
370
2,820
1
185
37 /
2.52
17.64
3.4
1.2
31.4
0.4
2.1
38.2
2.0
0.100
520
21
422
3,390
1
240
61 /
2.25
20.25
3.4
1.2
34.1
0.4
2.2
41.1
2.1
0.0762
460
21
496
4,090
1
300
61 /
2.52
22.68
3.4
1.2
36.8
0.4
2.4
44.2
2.3
0.0607
420
21
571
4,900
0
Datasheet Ref: OFS-NK-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 NEK606
Medium Voltage Power Cables to NEK606 Specification
RFOU Power Cables, Multi Core, Armoured Cables:
Applicable Standards IEEE
NEK 606 IEC 60092-354 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228
Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009
IEC
6/10kV Flame Retardant
Conductor Identification The individual cores shall be identified by the coloured semi-conducting tape or coloured ribbon tape run longitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows: 3 Cores: Off-White (grey), Black and Red New harmonised core colours or project specified colours can be supplied upon special request.
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Conductor Screen:
Semi-conductive tape or extruded semi-conductive compound.
(3) Insulation:
EP-Rubber
(4) Insulation Screen:
Semi-conductive tape or extruded semi-conductive compound.
(5) Metallic Screen:
Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)
(6) Bedding:
Flame retardant halogen free compound. PET Tape
(7) Armour:
Tinned copper wire braid. PET Tape
(8) Outer Sheath
SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour
Datasheet Ref: OFS-NK-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
6/10kV Flame Retardant
Medium Voltage Power Cables to NEK606 Specification
RFOU Multi Core Armoured Cables Conductor No. of Cores
Nominal Area
Strand
Overall diameter Dia.
Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering
Conductor Resistance (at 20ºC) (Max.)
Insulation Resistance (at 20ºC) (Min.)
Test Voltage
Current Carrying Capacity (Max.) (at 45ºC)
Cable Weight
No.
mm²
NO./
mm
mm
mm
mm
mm
mm
mm
mm
±mm
Ω / km
MΏ-km
V/5min.
A
kg/km
3
25
7/
2.14
6.42
3.4
1.4
41.0
0.4
2.5
48.6
2.4
0.734
1,150
21
85
3,840
3
35
7/
2.52
7.56
3.4
1.4
43.6
0.4
2.6
51.4
2.6
0.529
1,020
21
105
4,400
3
50
19 /
1.78
8.90
3.4
1.4
46.4
0.4
2.7
54.4
2.7
0.391
900
21
130
5,080
3
70
19 /
2.14
10.70
3.4
1.6
50.7
0.4
2.9
59.1
2.9
0.270
780
21
161
6,210
3
95
19 /
2.52
12.60
3.4
1.6
54.8
0.4
3.1
63.6
3.0
0.195
690
21
195
7,480
3
120
37 /
2.03
14.21
3.4
1.6
58.3
0.4
3.2
67.3
3.2
0.154
620
21
225
8,640
3
150
37 /
2.25
15.75
3.4
1.6
61.7
0.4
3.4
71.1
3.3
0.126
570
21
258
9,880
3
185
37 /
2.52
17.64
3.4
1.8
66.0
0.4
3.5
75.6
3.5
0.100
520
21
295
11,530
3
240
61 /
2.25
20.25
3.4
1.8
71.8
0.4
3.8
82.0
3.8
0.0762
460
21
347
14,020
0
Datasheet Ref: OFS-NK-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883
Medium Voltage Power Cables to NEK606 Specification NEK606
8.7/15kV Flame Retardant RFOU Power Cables, Single Core, Armoured Cables:
Applicable Standards
IEC
IEEE
NEK 606 IEC 60092-354 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228
Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009
Conductor Identification One core: Black New harmonised core colours or project specified colours can be supplied upon special request. Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Conductor Screen:
Semi-conductive tape or extruded semi-conductive compound.
(3) Insulation:
EP-Rubber
(4) Insulation Screen:
Semi-conductive tape or extruded semi-conductive compound.
(5) Metallic Screen:
Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)
(6) Bedding:
Flame retardant halogen free compound. PET Tape
(7) Armour:
Tinned copper wire braid. PET Tape
(8) Outer Sheath
SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour
Datasheet Ref: OFS-NK-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
8.7/15kV Flame Retardant
Medium Voltage Power Cables to NEK606 Specification
RFOU Single Core Armoured Cables Conductor No. of Cores
Nominal Area
Strand
Overall diameter Dia.
Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering
Conductor Resistance (at 20ºC) (Max.)
Insulation Resistance (at 20ºC) (Min.)
Test Voltage
Current Carrying Capacity (Max.) (at 45ºC)
Cable Weight
No.
mm²
NO./
mm
mm
mm
mm
mm
mm
mm
mm
±mm
Ω / km
MΏ-km
V/5min.
A
kg/km
1
25
7/
2.14
6.42
4.5
1.0
22.0
0.3
1.7
27.5
1.6
0.734
1,400
30.5
121
1,270
1
35
7/
2.52
7.56
4.5
1.0
23.2
0.3
1.8
28.9
1.7
0.529
1,250
30.5
149
1,440
1
50
19 /
1.78
8.90
4.5
1.0
24.5
0.3
1.8
30.2
1.7
0.391
1,110
30.5
186
1,630
1
70
19 /
2.14
10.70
4.5
1.0
26.3
0.3
1.9
32.2
1.8
0.270
970
30.5
230
1,950
1
95
19 /
2.52
12.60
4.5
1.2
28.6
0.3
2.0
34.7
1.9
0.195
860
30.5
278
2,350
1
120
37 /
2.03
14.21
4.5
1.2
30.2
0.4
2.1
37.0
2.0
0.154
780
30.5
322
2,800
1
150
37 /
2.25
15.75
4.5
1.2
31.8
0.4
2.2
38.8
2.1
0.126
720
30.5
370
3,170
1
185
37 /
2.52
17.64
4.5
1.2
33.6
0.4
2.2
40.6
2.1
0.100
660
30.5
422
3,620
1
240
61 /
2.25
20.25
4.5
1.2
36.6
0.4
2.3
43.8
2.3
0.0762
590
30.5
496
4,400
1
300
61 /
2.52
22.68
4.5
1.4
39.4
0.4
2.5
47.0
2.4
0.0607
530
30.5
571
5,190
0
Datasheet Ref: OFS-NK-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 NEK606
Medium Voltage Power Cables to NEK606 Specification
RFOU Power Cables, Multi Core, Armoured Cables:
Applicable Standards IEEE
NEK 606 IEC 60092-354 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228
Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009
IEC
8.7/15kV Flame Retardant
Conductor Identification The individual cores shall be identified by the coloured semi-conducting tape or coloured ribbon tape run longitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows: 3 Cores: Off-White (grey), Black and Red New harmonised core colours or project specified colours can be supplied upon special request.
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Conductor Screen:
Semi-conductive tape or extruded semi-conductive compound.
(3) Insulation:
EP-Rubber
(4) Insulation Screen:
Semi-conductive tape or extruded semi-conductive compound.
(5) Metallic Screen:
Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)
(6) Bedding:
Flame retardant halogen free compound. PET Tape
(7) Armour:
Tinned copper wire braid. PET Tape
(8) Outer Sheath
SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour
Datasheet Ref: OFS-NK-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
8.7/15kV Flame Retardant
Medium Voltage Power Cables to NEK606 Specification
RFOU Multi Core Armoured Cables Conductor No. of Cores
Nominal Area
Strand
Overall diameter Dia.
Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering
Conductor Resistance (at 20ºC) (Max.)
Insulation Resistance (at 20ºC) (Min.)
Test Voltage
Current Carrying Capacity (Max.) (at 45ºC)
Cable Weight
No.
mm²
NO./
mm
mm
mm
mm
mm
mm
mm
mm
±mm
Ω / km
MΏ-km
V/5min.
A
kg/km
3
25
7/
2.14
6.42
4.5
1.4
45.8
0.4
2.7
53.8
2.7
0.734
1,400
30.5
85
4,520
3
35
7/
2.52
7.56
4.5
1.6
48.8
0.4
2.8
57.0
2.8
0.529
1,250
30.5
105
5,180
3
50
19 /
1.78
8.90
4.5
1.6
51.6
0.4
2.9
60.0
2.9
0.391
1,110
30.5
130
5,890
3
70
19 /
2.14
10.70
4.5
1.6
55.5
0.4
3.1
64.3
3.1
0.270
970
30.5
161
7,030
3
95
19 /
2.52
12.60
4.5
1.6
59.5
0.4
3.3
68.7
3.2
0.195
860
30.5
195
8,330
3
120
37 /
2.03
14.21
4.5
1.6
63.0
0.4
3.4
72.4
3.4
0.154
780
30.5
225
9,530
3
150
37 /
2.25
15.75
4.5
1.8
66.8
0.4
3.6
76.6
3.6
0.126
720
30.5
258
10,890
3
185
37 /
2.52
17.64
4.5
1.8
70.7
0.4
3.7
80.7
3.7
0.100
660
30.5
295
12,520
0
Datasheet Ref: OFS-NK-PC-MV-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
Section 6 Medium Voltage Power Cables to NEK 606 Specification
BFOU FIRE RESISTANT
FPAL Verify
Verified No.10049350
ABS
6
BS6883
Medium Voltage Power Cables to NEK 606 Specification
BFOU - Power/Control Cables â&#x20AC;&#x201C; Single Core, Medium Power, armoured cables
NEK606
3.6/6 kV Fire Resistant
Applicable Standards
IEC
IEEE
NEK 606 IEC 60092-354 IEC 60331 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228
Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009
Conductor Identification One core: Black New harmonised core colours or project specified colours can be supplied upon special request.
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Fire Protection:
Mica Glass Tape
(3) Insulation:
EP-Rubber
(4) Insulation Screen:
Semi-conductive tape or extruded semi-conductive compound.
(5) Metallic Screen:
Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)
(6) Bedding:
Flame retardant halogen free compound. PET Tape
(7) Amour:
Tinned copper wire braid. PET Tape
(8) Outer Sheath:
SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour
Datasheet Ref: OFS-NK-PC-MV-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com
FPAL Verify
Verified
No.10049350
ABS
3.6/6 kV Fire Resistant
Medium Voltage Power Cables to NEK 606 Specification
BFOU Single Core Armoured Cables Conductor No. of Cores
Nominal Area
Strand
Overall diameter Dia.
Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering
Conductor Resistance (at 20ºC) (Max.)
Insulation Resistance (at 20ºC) (Min.)
Test Voltage
Current Carrying Capacity (Max.) (at 45ºC)
Cable Weight
No.
mm²
NO./
mm
mm
mm
mm
mm
mm
mm
mm
±mm
Ω / km
MΏ-km
V/5min.
A
kg/km
1
25
7/
2.14
6.42
2.5
1.0
20.3
0.3
1.7
26.1
1.5
0.734
920
12.5
114
1,190
1
35
7/
2.52
7.56
2.5
1.0
21.4
0.3
1.7
27.2
1.6
0.529
810
12.5
141
1,360
1
50
19 /
1.78
8.90
2.5
1.0
22.7
0.3
1.8
28.7
1.6
0.391
710
12.5
176
1,590
1
70
19 /
2.14
10.70
2.5
1.0
24.5
0.3
1.8
30.5
1.7
0.270
610
12.5
218
1,920
1
95
19 /
2.52
12.60
2.5
1.0
26.4
0.3
1.9
32.6
1.8
0.195
530
12.5
264
2,330
1
120
37 /
2.03
14.21
2.5
1.2
28.4
0.3
2.0
34.8
1.9
0.154
480
12.5
305
2,760
1
150
37 /
2.25
15.75
2.5
1.2
30.0
0.4
2.1
37.2
2.0
0.126
440
12.5
350
3,280
1
185
37 /
2.52
17.64
2.5
1.2
31.9
0.4
2.2
39.3
2.1
0.100
400
12.5
400
3,830
1
240
61 /
2.25
20.25
2.6
1.2
34.7
0.4
2.3
42.3
2.2
0.0762
360
12.5
470
4,690
1
300
61 /
2.52
22.68
2.8
1.4
38.2
0.4
2.4
46.1
2.3
0.0607
350
12.5
541
5,710
0
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
Datasheet Ref: OFS-NK-PC-MV-FS www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883
Medium Voltage Power Cables to NEK 606 Specification
BFOU - Power/Control Cables â&#x20AC;&#x201C; Multi Core, Medium Power, armoured cables
NEK606
3.6/6 kV Fire Resistant
Applicable Standards
IEC
IEEE
NEK 606 IEC 60092-354 IEC 60331 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228
Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009
Conductor Identification The individual cores shall be identified by the coloured semiconducting tape or coloured ribbon tape run longitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows: 3 Cores: Off-White (grey), Black and Red Note: picture is for illustration purposes only
New harmonised core colours or project specified colours can be supplied upon special request.
Construction
Specifications
(1) Conductor:
Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Fire Protection:
Mica Glass Tape
(3) Insulation:
EP-Rubber
(4) Insulation Screen:
Semi-conductive tape or extruded semi-conductive compound.
(5) Metallic Screen:
Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)
(6) Bedding:
Flame retardant halogen free compound. PET Tape
(7) Amour:
Tinned copper wire braid. PET Tape
(8) Outer Sheath:
SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour
Datasheet Ref: OFS-NK-PC-MV-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
3.6/6 kV Fire Resistant
Medium Voltage Power Cables to NEK 606 Specification
BFOU Multi Core Armoured Cables Conductor No. of Cores
Nominal Area
Strand
Overall diameter Dia.
Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering
Conductor Resistance (at 20ºC) (Max.)
Insulation Resistance (at 20ºC) (Min.)
Test Voltage
Current Carrying Capacity (Max.) (at 45ºC)
Cable Weight
No.
mm²
NO./
mm
mm
mm
mm
mm
mm
mm
mm
±mm
Ω / km
MΏ-km
V/5min.
A
kg/km
3
25
7/
2.14
6.42
2.5
1.4
41.9
0.4
2.6
50.2
2.5
0.734
920
12.5
80
4,110
3
35
7/
2.52
7.56
2.5
1.4
44.3
0.4
2.7
52.8
2.6
0.529
810
12.5
99
4,720
3
50
19 /
1.78
8.90
2.5
1.4
47.1
0.4
2.8
55.9
2.7
0.391
710
12.5
123
5,500
3
70
19 /
2.14
10.70
2.5
1.6
51.3
0.4
2.9
60.3
2.9
0.270
610
12.5
152
6,730
3
95
19 /
2.52
12.60
2.5
1.6
55.4
0.4
3.1
64.8
3.1
0.195
530
12.5
185
8,170
3
120
37 /
2.03
14.21
2.5
1.6
58.9
0.4
3.2
68.6
3.2
0.154
480
12.5
213
9,510
3
150
37 /
2.25
15.75
2.5
1.6
62.3
0.4
3.4
72.4
3.4
0.126
440
12.5
245
10,930
3
185
37 /
2.52
17.64
2.5
1.8
66.8
0.4
3.6
77.4
3.6
0.100
400
12.5
280
12,910
3
240
61 /
2.25
20.25
2.6
1.8
73.4
0.4
3.8
84.4
3.9
0.0762
360
12.5
329
16,010
3
300
61 /
2.52
22.68
2.8
1.8
79.4
0.4
4.1
91.1
4.1
0.0607
350
12.5
379
19,190
0
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
Datasheet Ref: OFS-NK-PC-MV-FS www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883
Medium Voltage Power Cables to NEK 606 Specification
BFOU - Power/Control Cables â&#x20AC;&#x201C; Single Core, Medium Power, armoured cables
NEK606
6/10 kV Fire Resistant
Applicable Standards
IEC
IEEE
NEK 606 IEC 60092-354 IEC 60331 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228
Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009
Conductor Identification One core: Black New harmonised core colours or project specified colours can be supplied upon special request.
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Fire Protection:
Mica Glass Tape
(3) Insulation:
EP-Rubber
(4) Insulation Screen:
Semi-conductive tape or extruded semi-conductive compound.
(5) Metallic Screen:
Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)
(6) Bedding:
Flame retardant halogen free compound. PET Tape
(7) Amour:
Tinned copper wire braid. PET Tape
(8) Outer Sheath:
SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour
Datasheet Ref: OFS-NK-PC-MV-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
6/10 kV Fire Resistant
Medium Voltage Power Cables to NEK 606 Specification
BFOU Single Core Armoured Cables Conductor No. of Cores
Nominal Area
Strand
Overall diameter Dia.
Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering
Conductor Resistance (at 20ºC) (Max.)
Insulation Resistance (at 20ºC) (Min.)
Test Voltage
Current Carrying Capacity (Max.) (at 45ºC)
Cable Weight
No.
mm²
NO./
mm
mm
mm
mm
mm
mm
mm
mm
±mm
Ω / km
MΏ-km
V/5min.
A
kg/km
1
25
7/
2.14
6.42
3.4
1.0
22.6
0.3
1.8
28.6
1.6
0.734
1,150
21.5
114
1,360
1
35
7/
2.52
7.56
3.4
1.0
23.7
0.3
1.8
29.7
1.7
0.529
1,020
21.5
141
1,540
1
50
19 /
1.78
8.90
3.4
1.0
25.1
0.3
1.9
31.3
1.8
0.391
900
21.5
176
1,770
1
70
19 /
2.14
10.70
3.4
1.0
26.9
0.3
1.9
33.1
1.8
0.270
780
21.5
218
2,120
1
95
19 /
2.52
12.60
3.4
1.2
29.2
0.3
2.0
35.7
1.9
0.195
690
21.5
264
2,590
1
120
37 /
2.03
14.21
3.4
1.2
30.8
0.4
2.1
38.0
2.0
0.154
620
21.5
305
3,090
1
150
37 /
2.25
15.75
3.4
1.2
32.3
0.4
2.2
39.7
2.1
0.126
570
21.5
350
3,510
1
185
37 /
2.52
17.64
3.4
1.2
34.2
0.4
2.3
41.8
2.2
0.100
520
21.5
400
4,070
1
240
61 /
2.25
20.25
3.4
1.2
37.1
0.4
2.4
44.9
2.3
0.0762
460
21.5
470
4,980
1
300
61 /
2.52
22.68
3.4
1.4
39.9
0.4
2.5
48.0
2.4
0.0607
420
21.5
541
5,920
0
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
Datasheet Ref: OFS-NK-PC-MV-FS www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883
Medium Voltage Power Cables to NEK 606 Specification
BFOU - Power/Control Cables â&#x20AC;&#x201C; Multi Core, Medium Power, armoured cables
NEK606
6/10 kV Fire Resistant
Applicable Standards
IEC
IEEE
NEK 606 IEC 60092-354 IEC 60331 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228
Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009
Conductor Identification The individual cores shall be identified by the coloured semiconducting tape or coloured ribbon tape run longitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows: 3 Cores: Off-White (grey), Black and Red Note: picture is for illustration purposes only
New harmonised core colours or project specified colours can be supplied upon special request.
Construction
Specifications
(1) Conductor:
Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Fire Protection:
Mica Glass Tape
(3) Insulation:
EP-Rubber
(4) Insulation Screen:
Semi-conductive tape or extruded semi-conductive compound.
(5) Metallic Screen:
Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)
(6) Bedding:
Flame retardant halogen free compound. PET Tape
(7) Amour:
Tinned copper wire braid. PET Tape
(8) Outer Sheath:
SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour
Datasheet Ref: OFS-NK-PC-MV-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
6/10 kV Fire Resistant
Medium Voltage Power Cables to NEK 606 Specification
BFOU Multi Core Armoured Cables Conductor No. of Cores
Nominal Area
Strand
Overall diameter Dia.
Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering
Conductor Resistance (at 20ºC) (Max.)
Insulation Resistance (at 20ºC) (Min.)
Test Voltage
Current Carrying Capacity (Max.) (at 45ºC)
Cable Weight
No.
mm²
NO./
mm
mm
mm
mm
mm
mm
mm
mm
±mm
Ω / km
MΏ-km
V/5min.
A
kg/km
3
25
7/
2.14
6.42
3.4
1.4
46.8
0.4
2.8
55.6
2.7
0.734
1,150
21.5
80
4,860
3
35
7/
2.52
7.56
3.4
1.6
49.6
0.4
2.9
58.6
2.8
0.529
1,020
21.5
99
5,570
3
50
19 /
1.78
8.90
3.4
1.6
52.6
0.4
3.0
61.8
3.0
0.391
900
21.5
123
6,390
3
70
19 /
2.14
10.70
3.4
1.6
56.5
0.4
3.1
66.0
3.1
0.270
780
21.5
152
7,650
3
95
19 /
2.52
12.60
3.4
1.6
60.6
0.4
3.3
70.5
3.3
0.195
690
21.5
185
9,160
3
120
37 /
2.03
14.21
3.4
1.8
64.5
0.4
3.5
74.8
3.5
0.154
620
21.5
213
10,640
3
150
37 /
2.25
15.75
3.4
1.8
67.7
0.4
3.6
78.3
3.6
0.126
570
21.5
245
12,080
3
185
37 /
2.52
17.64
3.4
1.8
71.8
0.4
3.8
82.8
3.8
0.100
520
21.5
280
14,030
3
240
61 /
2.25
20.25
3.4
1.8
77.9
0.4
4.0
89.4
4.1
0.0762
460
21.5
329
17,140
3
300
61 /
2.52
22.68
3.4
1.8
83.1
0.4
4.2
95.0
4.3
0.0607
420
21.5
379
20,160
0
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
Datasheet Ref: OFS-NK-PC-MV-FS www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883
Medium Voltage Power Cables to NEK 606 Specification
BFOU - Power/Control Cables â&#x20AC;&#x201C; Single Core, Medium Power, armoured cables
NEK606
8.7/15 kV Fire Resistant
Applicable Standards
IEC
IEEE
NEK 606 IEC 60092-354 IEC 60331 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228
Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009
Conductor Identification One core: Black New harmonised core colours or project specified colours can be supplied upon special request.
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Fire Protection:
Mica Glass Tape
(3) Insulation:
EP-Rubber
(4) Insulation Screen:
Semi-conductive tape or extruded semi-conductive compound.
(5) Metallic Screen:
Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)
(6) Bedding:
Flame retardant halogen free compound. PET Tape
(7) Amour:
Tinned copper wire braid. PET Tape
(8) Outer Sheath:
SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour
Datasheet Ref: OFS-NK-PC-MV-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
8.7/15 kV Fire Resistant
Medium Voltage Power Cables to NEK 606 Specification
BFOU Single Core Armoured Cables Conductor No. of Cores
Nominal Area
Strand
Overall diameter Dia.
Thickness of Thickness of Nominal dia. Insulation inner covering Inner covering
Dia. Of wire for armour
Thickness of sheath
Nominal
Tolerance
Cable Weight
No.
mm²
NO./
mm
mm
mm
mm
mm
mm
mm
mm
±mm
kg/km
1
25
7/
2.14
6.60
4.5
1.0
25.0
0.3
1.9
30.9
1.7
1,520
1
35
7/
2.52
7.90
4.5
1.0
26.1
0.3
1.9
32.0
1.8
1,700
1
50
19 /
1.78
9.10
4.5
1.2
27.9
0.3
2.0
34.0
1.9
1,980
1
70
19 /
2.14
11.00
4.5
1.2
29.5
0.3
2.0
35.6
1.9
2,290
1
95
19 /
2.52
12.90
4.5
1.2
31.3
0.4
2.1
38.1
2.0
2,820
1
120
37 /
2.03
14.50
4.5
1.2
33.0
0.4
2.2
40.0
2.1
3,240
1
150
37 /
2.25
16.20
4.5
1.2
34.4
0.4
2.3
41.6
2.2
3,640
1
185
37 /
2.52
18.00
4.5
1.2
36.3
0.4
2.3
43.5
2.2
4,170
1
240
61 /
2.25
20.60
4.5
1.4
39.5
0.4
2.5
47.1
2.4
5,130
1
300
61 /
2.52
23.10
4.5
1.4
41.9
0.4
2.6
49.7
2.5
6,000
0
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
Datasheet Ref: OFS-NK-PC-MV-FS www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883
Medium Voltage Power Cables to NEK 606 Specification
BFOU - Power/Control Cables â&#x20AC;&#x201C; Multi Core, Medium Power, armoured cables
NEK606
8.7/15 kV Fire Resistant
Applicable Standards
IEC
IEEE
NEK 606 IEC 60092-354 IEC 60331 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228
Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009
Conductor Identification The individual cores shall be identified by the coloured semiconducting tape or coloured ribbon tape run longitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows: 3 Cores: Off-White (grey), Black and Red Note: picture is for illustration purposes only
New harmonised core colours or project specified colours can be supplied upon special request.
Construction
Specifications
(1) Conductor:
Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Fire Protection:
Mica Glass Tape
(3) Insulation:
EP-Rubber
(4) Insulation Screen:
Semi-conductive tape or extruded semi-conductive compound.
(5) Metallic Screen:
Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)
(6) Bedding:
Flame retardant halogen free compound. PET Tape
(7) Amour:
Tinned copper wire braid. PET Tape
(8) Outer Sheath:
SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour
Datasheet Ref: OFS-NK-PC-MV-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
8.7/15 kV Fire Resistant
Medium Voltage Power Cables to NEK 606 Specification
BFOU Multi Core Armoured Cables Overall diameter
Conductor No. of Cores
Nominal Area
Strand
Dia.
Thickness of Thickness of Nominal dia. Insulation inner covering Inner covering
Dia. Of wire for armour
Thickness of sheath
Nominal
Tolerance
Cable Weight
No.
mm²
NO./
mm
mm
mm
mm
mm
mm
mm
mm
±mm
kg/km
3
25
7/
2.14
6.60
4.5
1.6
51.8
0.4
3.0
60.4
2.9
5,500
3
35
7/
2.52
7.90
4.5
1.6
54.2
0.4
3.1
63.0
3.0
6,170
3
50
19 /
1.78
9.10
4.5
1.6
57.2
0.4
3.2
66.2
3.1
7,020
3
70
19 /
2.14
11.00
4.5
1.6
60.6
0.4
3.3
69.8
3.3
8,150
3
95
19 /
2.52
12.90
4.5
1.8
64.9
0.4
3.5
74.5
3.5
9,690
3
120
37 /
2.03
14.50
4.5
1.8
68.6
0.4
3.6
78.4
3.6
11,120
3
150
37 /
2.25
16.20
4.5
1.8
71.6
0.4
3.7
81.6
3.8
12,460
3
185
37 /
2.52
18.00
4.5
1.8
75.7
0.4
3.9
86.1
3.9
14,380
3
240
61 /
2.25
20.60
4.5
1.8
81.6
0.4
4.1
92.4
4.2
17,410
3
300
61 /
2.52
23.10
4.5
2.0
87.2
0.4
4.4
98.6
4.4
20,520
0
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
Datasheet Ref: OFS-NK-PC-MV-FS www.interkab.com FPAL Verify
Verified
No.10049350
ABS
Section 7 Marine Instrument Cables Marine Power & Control Cables
FPAL Verify
Verified No.10049350
ABS
7
BS6883 IEC 600/1000V Fire Resistant
IEC 60092-353 - Power Cables Armoured:
NEK606 NEK606
Marine Cables to IEC 60092-353 Specification
Applicable Standards
IEEE IEEE
IEC 60092-353 IEC 60092-351 IEC 60092-350 IEC 60332 part 3 (Category A) IEC 60331-21 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228
IEC BS6883
Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Conductor Identification One core: Black Two cores: Brown - Blue Two cores + Earth: Brown - Blue - Yellow/Green Three Cores: Brown - Black - Grey Three Cores + Earth: Brown - Black - Grey - Yellow/Green Four Cores: Blue - Brown - Black - Grey Four Cores + Earth: Blue - Brown - Black - Grey - Yellow/Green Five Cores & above: Black numbers on white base. New harmonised core colours or project specified colours can be supplied upon special request
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to IEC 60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Mica tape:
Layer of mica tape
(3) Insulation:
XLPE Complying with IEC 60092-351
(4) Bedding:
Lapped or Extruded Halogen Free Compound
(5) Armour:
Tinned or Plain Copper wire braid to IEC 60092-350
(6) Outer Sheath:
Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359
Datasheet Ref: MC-PC-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000V Fire Resistant
Marine Cables to IEC 60092-353 Specification
Marine Single Core Armoured Cables - Table 1/4 Cable
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
Approximate Overall Diameter (mm)
10
11
Current rating (A)
72
96
13
14
16.5
18.5
20.5
22.5
127
157
196
242
293
339
Approximate Weight (kg/km)
195
270
390
495
Min. bending radius fixed installation (mm)
60
70
80
85
670
915
1180
1465
100
115
125
135
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
2 x 25
1 x 150
1 x 185
1 x 240
1 x 300
25
28
30.5
34
389
444
522
601
1770
2190
2820
3475
150
170
185
205
Orange
Orange
Orange
Orange
Orange
2 x 35
2 x 50
3 x 1.5
3 x 2.5
3x4 13.5
Marine Multi Core Armoured Cables - Table 2/4 2 x 1.5
2 x 2.5
Approximate Overall Diameter (mm)
Cable
2x4
2x6
2 x 10
11
11.5
Current rating (A)
20
26
Approximate Weight (kg/km)
145
175
225
2 x 16
13
14
16.5
19
23
25
28
11
12.5
34
44
61
82
108
133
167
16
21
28
340
505
700
1130
1420
1860
170
215
275
Min. bending radius fixed installation (mm)
60
70
80
85
100
115
125
140
160
70
75
85
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Marine Multi Core Armoured Cables - Table 3/4 Cable
3x6
3 x 10
3 x 16
3 x 25
3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
4 x 1.5
4 x 2.5
4x4
4x6
4 x 10
Approximate Overall Diameter (mm)
15
17.5
20
25
28
32
37
42
46
12.5
13.5
15.5
16.5
19.5
Current rating (A)
36
50
67
89
110
137
169
205
237
16
21
28
36
50
Approximate Weight (kg/km)
430
595
845
1285
1655
2175
3005
4010
4925
210
260
370
505
720
Min. bending radius fixed installation (mm)
90
105
120
150
170
195
225
255
280
75
85
95
100
120
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Marine Multi Core Armoured Cables - Table 4/4 Cable
4 x 16
4 x 25
4 x 35
4 x 50
5 x 1.5
5 x 2.5
7 x 1.5
7 x 2.5
12 x 1.5
12 x 2.5
19 x 1.5
19 x 2.5
27 x 1.5
27 x 2.5
37 x 1.5
Approximate Overall Diameter (mm)
22.5
27.5
30.5
35.5
13.5
14.5
14.5
16.5
19
21.5
22.5
25
27
30
30
Current rating (A)
67
89
110
137
14
18
12
16
10
13
9
11
8
10
7
Approximate Weight (kg/km)
1050
1570
2035
2700
245
310
295
415
495
665
705
950
965
1325
1260
Min. bending radius fixed installation (mm)
135
165
185
215
85
90
90
100
115
130
135
150
165
180
180
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Datasheet Ref: MC-PC-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 600/1000V Flame Retardant
IEC 60092-353 - Power Cables Armoured:
NEK606
Marine Cables to IEC 60092-353 Specification
Applicable Standards
IEEE
IEC 60092-353 IEC 60092-351 IEC 60092-350 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228
Application IEC
This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Conductor Identification One core: Black Two cores: Brown - Blue Two cores + Earth: Brown - Blue - Yellow/Green Three Cores: Brown - Black - Grey Three Cores + Earth: Brown - Black - Grey - Yellow/Green Four Cores: Blue - Brown - Black - Grey Four Cores + Earth: Blue - Brown - Black - Grey - Yellow/Green Five Cores & above: Black numbers on white base. New harmonised core colours or project specified colours can be supplied upon special request
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to IEC 60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Insulation:
XLPE Complying with IEC 60092-351
(3) Bedding:
Lapped or Extruded Halogen Free Compound
(4) Armour:
Tinned or Plain Copper wire braid to IEC 60092-350
(5) Outer Sheath:
Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359
Datasheet Ref: MC-PC-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000V Flame Retardant
Marine Cables to IEC 60092-353 Specification
Marine Single Core Armoured Cables - Table 1/5 1 x 1.5
1 x 2.5
Approximate Overall Diameter (mm)
Cable
1x4
1x6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50
5
5.4
6
7
Current rating (A)
23
30
40
52
Approximate Weight (kg/km)
40
50
70
95
140
1 x 70
1 x 95
1 x 120
1 x 150
8
9
11.5
12.5
72
96
127
157
205
320
420
1 x 185
1 x 240
1 x 300
14.5
17
18.5
20.5
23.5
196
242
293
339
389
26
29
31.5
444
522
555
790
1040
1300
1610
2005
601
2615
3235
Min. bending radius fixed installation (mm)
15
20
25
30
35
40
50
50
60
70
75
85
95
160
175
190
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Marine Multi Core Armoured Cables - Table 2/5 Cable
2 x 1.5
2 x 2.5
2x4
2x6
2 x 10
2 x 16
2 x 25
2 x 35
2 x 50
3 x 1.5
3 x 2.5
3x4
3x6
3 x 10
3 x 16
3 x 25
Approximate Overall Diameter (mm)
10
10.5
12
13
15.5
18
22.5
25
26.5
10
11
12.5
14
16.5
19
24
Current rating (A)
20
26
34
44
61
82
108
133
197
16
21
28
36
50
67
89
Approximate Weight (kg/km)
130
160
205
315
480
665
1030
1305
1500
155
195
260
370
570
805
1240
Min. bending radius fixed installation (mm)
60
65
75
80
95
110
135
150
170
60
70
75
85
100
115
145
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Marine Multi Core Armoured Cables - Table 3/5 Cable
3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150
4 x 1.5
4 x 2.5
4x4
4x6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
Approximate Overall Diameter (mm)
27
31.5
36
40
45
50
11
12.5
13.5
15.5
18
21.5
26.5
29.5
34.5
Current rating (A)
110
137
169
205
237
272
16
21
28
36
50
67
89
110
137
Approximate Weight (kg/km)
1600
2125
2970
3825
4890
5970
180
240
315
475
695
1020
1540
2030
2675
Min. bending radius fixed installation (mm)
165
190
220
240
270
300
70
75
85
95
110
130
160
180
210
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Datasheet Ref: MC-PC-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000V Flame Retardant
Marine Cables to IEC 60092-353 Specification
Marine Multi Core Armoured Cables - Table 4/5 Cable
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95
4 x 120
4 x 150
4 x 185
4 x 240
4 x 300
5 x 1.5
5 x 2.5
7 x 1.5
Nominal Conductor Stranding mm
56/0.52
80/0.52
128/0.52
176/0.52
240/0.52
360/0.52
496/0.52
624/0.52
768/0.52
960/0.52
1280/0.52
1504/0.52
7/0.53
7/0.67
7/0.53
Minimum Overall Diameter (mm)
16.97
19.88
23.76
26.67
30.07
36.37
39.28
43.65
48.01
53.35
59.65
65.96
11.15
12.61
12.12
Maximum Overall Diameter (mm)
17.5
20.5
24.5
27.5
31
37.5
40.5
45
49.5
55
61.5
68
11.5
13
12.5
Approximate Weight (kg/km)
685
980
1460
1940
2640
3710
4810
5960
7370
9040
11510
14270
205
270
250
Hawke Flame Proof Stuffing Gland
-25H-A
-32H-A
-32H-A
-40H-A
-40H-A
-50H-A
-50H-A
-63H-A
-63H-A
-63H-A
-75H-A
-75H-A
-20SH-A
-20H-A
-20H-A
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Marine Multi Core Armoured Cables - Table 5/5 Cable
7 x 2.5
10 x 1.5
12 x 1.5
12 x 2.5
14 x 1.5
17 x 1.5
19 x 1.5
19 x 2.5
24 x 1.5
27 x 1.5
27 x 2.5
30 x 1.5
37 x 1.5
37 x 2.5
Nominal Conductor Stranding mm
7/0.67
7/0.53
7/0.53
7/0.67
7/0.53
7/0.53
7/0.53
7/0.67
7/0.53
7/0.53
7/0.67
7/0.53
7/0.53
7/0.67
Minimum Overall Diameter (mm)
14.06
16
16.49
17.94
16.97
17.94
19.4
21.82
22.79
23.28
25.7
24.25
25.7
29.1
Maximum Overall Diameter (mm)
14.5
16.5
17
18.5
17.5
18.5
20
22.5
23.5
24
26.5
25
26.5
30
Approximate Weight (kg/km)
380
400
440
585
490
540
620
870
790
850
1170
930
1090
1530
Hawke Flame Proof Stuffing Gland
-25H-A
-25H-A
-25H-A
-25H-A
-25H-A
-25H-A
-25H-A
-32H-A
-32H-A
-32H-A
-40H-A
-32H-A
-40H-A
-40H-A
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Datasheet Ref: MC-PC-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 IEC 150/250V Fire Resistant
IEC 60092-376 - Instrumentation Cables Armoured - Collective Screen
NEK606 NEK606
Marine Cables to IEC 60092-376 Specification
Applicable Standards
IEC BS6883
IEEE IEEE
IEC 60092-376 IEC 60092-351 IEC 60092-350 IEC 60332 part 3 (Category A) IEC 60331-21 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228
Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Conductor Identification Pair: White / Blue with printed pair number Triple: White / Blue / Brown with printed triple number New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to IEC 60228 Class 2
(2) Mica tape:
Layer of mica tape
(3) Insulation:
XLPE Complying with IEC 60092-351
(4) Bedding:
Lapped polyester tape / filler tape
(5) Armour:
Copper wire braid with copper drain wire to IEC 60092-350
(6) Outer Sheath:
Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359
Datasheet Ref: MC-INS-CS-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250V Fire Resistant
Marine Cables to IEC 60092-376 Specification
Marine Instrumentation Armoured Cables - Collective Screen - Table 1/3 Cable
1x2x0.75
2x2x0.75
4x2x0.75
7x2x0.75
8x2x0.75
10x2x0.75
12x2x0.75
14x2x0.75
19x2x0.75
24x2x0.75
Approximate Overall Diameter (mm)
9.5
11
16.5
20
21
24.5
25.5
27
1
34.5
Approximate Weight (kg/km)
115
160
325
465
510
630
705
800
1015
1245
Min. bending radius fixed installation (mm)
60
70
100
120
130
150
155
165
190
210
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Marine Instrumentation Armoured Cables - Collective Screen - Table 2/3
Cable
1x3x0.75
2x3x0.75
4x3x0.75
7x3x0.75
10x3x0.75
1x2x1.5
2x2x1.5
4x2x1.5
7x2x1.5
Approximate Overall Diameter (mm)
8.5
13
14.5
18.5
21
10.5
12
18.5
22.5
Approximate Weight (kg/km)
120
260
360
550
750
155
220
430
650
Min. bending radius fixed installation (mm)
50
80
90
115
130
65
75
115
140
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
19x2x1.5
1x3x1.5
2x3x1.5
4x3x1.5
7x3x1.5
Marine Instrumentation Armoured Cables - Collective Screen - Table 3/3
Cable
8x2x1.5
10x2x1.5
12x2x1.5
14x2x1.5
Approximate Overall Diameter (mm)
24
27.5
29
30.5
32.5
9.5
16
17.5
22.5
Approximate Weight (kg/km)
715
875
1000
1125
1280
150
390
500
770
Min. bending radius fixed installation (mm)
140
150
165
175
185
60
100
105
140
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Datasheet Ref: MC-INS-CS-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 IEC 150/250V Fire Resistant
IEC 60092-376 - Instrumentation Cables Armoured - Individual Screen
NEK606 NEK606
Marine Cables to IEC 60092-376 Specification
Applicable Standards
IEC BS6883
IEEE IEEE
IEC 60092-376 IEC 60092-351 IEC 60092-350 IEC 60332 part 3 (Category A) IEC 60331-21 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228
Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Conductor Identification Pair: White / Blue with printed pair number Triple: White / Blue / Brown with printed triple number New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to IEC 60228 Class 2
(2) Mica tape:
Layer of mica tape
(3) Insulation:
XLPE Complying with IEC 60092-351
(4) Individual Screen:
Pairs / Triples screened with plastic coated aluminium tape and a tinned copper drain wire
(5) Bedding:
Lapped polyester tape / filler tape
(6) Armour:
Copper wire braid with copper drain wire to IEC 60092-350
(7) Outer Sheath:
Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359
Datasheet Ref: MC-INS-IS-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250V Fire Resistant
Marine Cables to IEC 60092-376 Specification
Marine Instrumentation Armoured Cables - Individual Screen - Table 1/3 Cable
1x2x0.75
2x2x0.75
4x2x0.75
7x2x0.75
8x2x0.75
Approximate Overall Diameter (mm)
9.5
14.5
17
20
22
Approximate Weight (kg/km)
125
225
355
515
585
10x2x0.75
12x2x0.75
14x2x0.75
19x2x0.75
24x2x0.75
25
26
27.5
32
35
710
800
910
1175
1425
Min. bending radius fixed installation (mm)
60
90
105
125
135
150
155
170
195
215
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Marine Instrumentation Armoured Cables - Individual Screen - Table 2/3
Cable
1x3x0.75
2x3x0.75
4x3x0.75
7x3x0.75
10x3x0.75
1x2x1.5
2x2x1.5
4x2x1.5
7x2x1.5
Approximate Overall Diameter (mm)
11
13.5
15.5
19
22
10.5
16.5
19
23
Approximate Weight (kg/km)
210
280
400
610
850
165
320
475
720
Min. bending radius fixed installation (mm)
65
80
95
115
135
65
100
115
140
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Marine Instrumentation Armoured Cables - Individual Screen - Table 3/3
Cable
8x2x1.5
10x2x1.5
12x2x1.5
14x2x1.5
19x2x1.5
24x2x1.5
1x3x1.5
2x3x1.5
4x3x1.5
Approximate Overall Diameter (mm)
24.5
28
29.5
31.5
33
37
15
16.5
18.5
Approximate Weight (kg/km)
810
985
1145
1295
1500
1970
310
420
550
Min. bending radius fixed installation (mm)
150
170
180
190
200
215
90
100
115
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Datasheet Ref: MC-INS-IS-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 150/250V Flame Retardant
IEC 60092-376 - Instrumentation Cables Armoured - Collective Screen
NEK606
Marine Cables to IEC 60092-376 Specification
Applicable Standards
IEEE
IEC 60092-376 IEC 60092-351 IEC 60092-350 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228
IEC
Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Conductor Identification Pair: White / Blue with printed pair number Triple: White / Blue / Red with printed triple number New harmonised core colours or project specified colours can be supplied upon special request
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to IEC 60228 Class 2
(2) Insulation:
XLPE Complying with IEC 60092-351
(3) Bedding:
Lapped polyester tape / filler tape
(4) Armour:
Copper wire braid with copper drain wire
(5) Outer Sheath:
Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359
Datasheet Ref: MC-INS-CS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250V Flame Retardant
Marine Cables to IEC 60092-376 Specification
Marine Instrumentation Armoured Cables - Collective Screen - Table 1/3 Cable
1x2x0.5
Approximate Overall Diameter (mm)
2x2x0.5
4x2x0.5
Approximate Weight (kg/km)
7x2x0.5
8x2x0.5
7.5
8
85
100
10x2x0.5
12x2x0.5
14x2x0.5
11.5
14
170
245
19x2x0.5
24x2x0.5
14.5
17
17.5
270
350
390
37x2x0.5
1x2x0.75
18.5
21
440
545
2x2x0.75
23.5
28
7.5
9
665
930
95
125
Min. bending radius fixed installation (mm)
45
50
70
85
90
105
105
115
130
145
170
45
55
Sheath Colour
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Marine Instrumentation Armoured Cables - Collective Screen - Table 2/3 Cable
4x2x0.75
7x2x0.75
8x2x0.75
1x3x0.75
2x3x0.75
4x3x0.75
7x3x0.75
10x3x0.75
Approximate Overall Diameter (mm)
12.5
15.5
16
10x2x0.75 12x2x0.75 14x2x0.75 19x2x0.75 24x2x0.75 18.5
19
20.5
23.5
26
8
12
13
17
19.5
Approximate Weight (kg/km)
215
330
375
440
490
565
715
860
100
200
250
420
580
Min. bending radius fixed installation (mm)
75
95
100
115
115
125
146
160
50
75
80
105
120
Sheath Colour
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Marine Instrumentation Armoured Cables - Collective Screen - Table 3/3 Cable
1x2x1.5
2x2x1.5
4x2x1.5
7x2x1.5
8x2x1.5
10x2x1.5
12x2x1.5
14x2x1.5
19x2x1.5
1x3x1.5
2x3x1.5
4x3x1.5
Approximate Overall Diameter (mm)
10
11
17
20
21.5
24.5
25.5
27
31
9
14.5
16.5
7x3x1.5 21
Approximate Weight (kg/km)
140
190
375
545
625
760
855
960
1230
140
300
430
660
Min. bending radius fixed installation (mm)
60
70
105
120
130
150
155
165
190
50
90
100
125
Sheath Colour
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Datasheet Ref: MC-INS-CS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 150/250V Flame Retardant
IEC 60092-376 - Instrumentation Cables Armoured - Individual Screen
NEK606
Marine Cables to IEC 60092-376 Specification
Applicable Standards
IEEE
IEC 60092-376 IEC 60092-351 IEC 60092-350 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228
IEC
Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Conductor Identification Pair: White / Blue with printed pair number Triple: White / Blue / Red with printed triple number New harmonised core colours or project specified colours can be supplied upon special request
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to IEC 60228 Class 2
(2) Insulation:
XLPE Complying with IEC 60092-351
(3) Individual Screen:
Pairs / Triples screened with plastic coated aluminium tape and a tinned copper drain wire
(4) Bedding:
Lapped polyester tape / filler tape
(5) Armour:
Copper wire braid with copper drain wire
(6) Outer Sheath:
Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359
Datasheet Ref: MC-INS-IS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250V Flame Retardant
Marine Cables to IEC 60092-376 Specification
Marine Instrumentation Armoured Cables - Individual Screen - Table 1/3 Cable
2x2x0.5
4x2x0.5
7x2x0.5
10x2x0.5
14x2x0.5
19x2x0.5
24x2x0.5
1x2x0.75
2x2x0.75
4x2x0.75
7x2x0.75
Approximate Overall Diameter (mm)
9.5
11
13
15.5
17
19.5
22
8
11.5
13
15.5
Approximate Weight (kg/km)
140
170
250
380
40
600
740
95
170
240
375
Min. bending radius fixed installation (mm)
60
65
75
100
110
120
130
50
70
75
100
Sheath Colour
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
24x2x0.75
2x3x0.75
4x3x0.75
7x3x0.75
10x3x0.75
Marine Instrumentation Armoured Cables - Individual Screen - Table 2/3 Cable
8x2x0.75
10x2x0.75
12x2x0.75
14x2x0.75
19x2x0.75
1x2x1.5
Approximate Overall Diameter (mm)
16.5
19
20
21
24
27
12.5
13.5
18
20.5
10
Approximate Weight (kg/km)
420
520
585
650
835
1035
230
290
500
700
150
Min. bending radius fixed installation (mm)
105
115
120
130
145
160
75
80
110
120
60
Sheath Colour
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
19x2x1.5
2x3x1.5
4x3x1.5
Marine Instrumentation Armoured Cables - Individual Screen - Table 3/3 Cable
2x2x1.5
4x2x1.5
7x2x1.5
8x2x1.5
10x2x1.5
12x2x1.5
14x2x1.5
Approximate Overall Diameter (mm)
14.5
17
20
22
25
26
28
32
15.5
17.5
Approximate Weight (kg/km)
255
415
610
700
855
965
1105
1440
380
490
Min. bending radius fixed installation (mm)
85
105
125
130
150
155
165
190
95
110
Sheath Colour
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Datasheet Ref: MC-INS-IS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
IEC BS6883
Marine Cables Cables to to IEC IEC 60092-353 60092-353 Specification Specification Marine
IEC 60092-353 - Power Cables Unarmoured:
NEK606 NEK606
600/1000V 600/1000V Flame Retardant Fire Resistant
Applicable Standards
IEEE IEEE
IEC 60092-353 IEC 60092-351 IEC 60332 part 3 (Category A) IEC 60331-21 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228
IEC BS6883
Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Conductor Identification One core: Black Two cores: Brown - Blue Two cores + Earth: Brown - Blue - Yellow/Green Three Cores: Brown - Black - Grey Three Cores + Earth: Brown - Black - Grey - Yellow/Green Four Cores: Blue - Brown - Black - Grey Four Cores + Earth: Blue - Brown - Black - Grey - Yellow/Green Five Cores & above: Black numbers on white base. New harmonised core colours or project specified colours can be supplied upon special request
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to IEC 60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Mica tape:
Layer of mica tape
(3) Insulation:
XLPE Complying with IEC 60092-351
(4) Bedding:
Lapped or Extruded Halogen Free Compound
(5) Outer Sheath:
Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359
Datasheet Ref: MC-PC-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000V Fire Resistant
Marine Cables to IEC 60092-353 Specification
Marine Single and Multi Core Unarmoured Cables - Table 1/3 Cable
1 x 25
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
2 x 1.5
2 x 2.5
2x4
2x6
2 x 10
2 x 16
3 x 1.5
Approximate Overall Diameter (mm)
10.5
11.5
13
15
17.5
20
9.5
10
12
13
15
17.5
10
3 x 2.5 11
Current rating (A)
127
157
196
242
293
339
20
26
34
44
61
82
16
21
Approximate Weight (kg/km)
310
410
560
780
1030
1290
100
125
165
265
380
555
125
160
Min. bending radius fixed installation (mm)
85
90
100
115
130
145
60
65
70
80
90
105
65
70
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Marine Multi Core Unarmoured Cables - Table 2/3 Cable
3x4
3x6
3 x 10
3 x 16
3 x 25
3 x 35
3 x 50
3 x 70
3 x 95
4 x 1.5
4 x 2.5
4x4
4x6
4 x 10
Approximate Overall Diameter (mm)
11.5
13
16
18.5
21.5
24.5
29
33
37
11
11.5
13.5
15
17
Current rating (A)
28
36
50
67
89
110
137
169
205
16
21
28
36
50
Approximate Weight (kg/km)
220
325
490
725
1100
1470
1955
2780
3655
150
205
280
410
605
Min. bending radius fixed installation (mm)
75
85
100
115
140
160
180
210
235
70
75
85
95
110
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Marine Multi Core Unarmoured Cables - Table 3/3 Cable
4 x 16
4 x 25
4 x 35
4 x 50
5 x 1.5
5 x 2.5
7 x 1.5
7 x 2.5
12 x 1.5
12 x 2.5
19 x 1.5
19 x 2.5
27 x 1.5
37 x 1.5
Approximate Overall Diameter (mm)
20.5
24
27.5
31.5
11.5
13
13
14.5
16.5
18.5
19.5
22
24
27
Current rating (A)
67
89
110
137
14
18
12
16
10
13
9
11
8
7
Approximate Weight (kg/km)
915
1405
1875
2510
190
251
235
315
380
525
580
795
800
1055
Min. bending radius fixed installation (mm)
125
155
175
205
75
85
80
90
105
120
130
140
155
170
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Datasheet Ref: MC-PC-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 600/1000V Flame Retardant
IEC 60092-353 - Power Cables Unarmoured:
NEK606
Marine Cables to IEC 60092-353 Specification
Applicable Standards
IEEE
IEC 60092-353 IEC 60092-351 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228
Application IEC
This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Conductor Identification One core: Black Two cores: Brown - Blue Two cores + Earth: Brown - Blue - Yellow/Green Three Cores: Brown - Black - Grey Three Cores + Earth: Brown - Black - Grey - Yellow/Green Four Cores: Blue - Brown - Black - Grey Four Cores + Earth: Blue - Brown - Black - Grey - Yellow/Green Five Cores & above: Black numbers on white base. New harmonised core colours or project specified colours can be supplied upon special request
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to IEC 60228 Class 2 (Flexible Class 5 conductors available upon request)
(2) Insulation:
XLPE Complying with IEC 60092-351
(3) Bedding:
Lapped or Extruded Halogen Free Compound
(4) Outer Sheath:
Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359
Datasheet Ref: MC-PC-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000V Flame Retardant
Marine Cables to IEC 60092-353 Specification
Marine Single Core Unarmoured Cables - Table 1/5 1 x 1.5
1 x 2.5
Approximate Overall Diameter (mm)
Cable
1x4
1x6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50
5
5.4
6
7
Current rating (A)
23
30
40
52
Approximate Weight (kg/km)
40
50
70
95
140
1 x 70
1 x 95
1 x 120
1 x 150
8
9
11.5
12.5
72
96
127
157
205
320
420
1 x 185
1 x 240
1 x 300
14.5
17
18.5
20.5
23.5
196
242
293
339
389
26
29
31.5
444
522
555
790
1040
1300
1610
2005
601
2615
3235
Min. bending radius fixed installation (mm)
15
20
25
30
35
40
50
50
60
70
75
85
95
160
175
190
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
2 x 10
2 x 16
2 x 25
2 x 35
2 x 50
3 x 1.5
3 x 2.5
3x4
3x6
3 x 10
3 x 16
3 x 25
Marine Multi Core Unarmoured Cables - Table 2/5 Cable
2 x 1.5
Approximate Overall Diameter (mm)
2 x 2.5
2x4
2x6
8.5
10
11
12
14
16.5
20.5
23.5
25
9
10
11.5
13
15
17.5
22
Current rating (A)
20
26
34
44
61
82
108
133
167
16
21
28
36
50
67
89
Approximate Weight (kg/km)
80
115
155
240
360
525
805
1100
1290
100
145
200
305
460
680
1045
Min. bending radius fixed installation (mm)
35
40
45
50
60
70
85
95
110
40
40
50
55
60
70
90
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
4 x 70
Marine Multi Core Unarmoured Cables - Table 3/5 Cable
3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150
4 x 1.5
4 x 2.5
4x4
4x6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
Approximate Overall Diameter (mm)
25
29
34
38
42.5
47.5
10
11
12.5
14
17
19.5
24.5
27.5
32.5
38
Current rating (A)
110
137
169
205
237
272
16
21
28
36
50
67
89
110
137
169
Approximate Weight (kg/km)
1425
1910
2740
3600
4525
5585
135
180
260
375
585
875
1355
1825
2460
3515
Min. bending radius fixed installation (mm)
150
175
205
230
255
285
40
45
50
60
70
80
100
165
195
230
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Datasheet Ref: MC-PC-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
600/1000V Flame Retardant
Marine Cables to IEC 60092-353 Specification
Marine Multi Core Unarmoured Cables - Table 4/5 Cable
4 x 95
4 x 120
5 x 1.5
5 x 2.5
5x4
5x6
5 x 10
5 x 16
7 x 1.5
7 x 2.5
10 x 1.5
10 x 2.5
12 x 1.5
12 x 2.5
Approximate Overall Diameter (mm)
42.5
47
11
12
14
15.5
18
21.5
12
13.5
15
17
15.5
17.5
Current rating (A)
205
237
14
18
25
30
44
56
12
16
11
14
10
13
Approximate Weight (kg/km)
4670
5820
160
220
315
465
710
1065
200
285
290
415
335
470
Min. bending radius fixed installation (mm)
255
285
45
50
60
65
75
90
50
55
60
70
65
70
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Marine Multi Core Unarmoured Cables - Table 5/5 Cable
14 x 1.5
14 x 2.5
16 x 1.5
16 x 2.5
19 x 1.5
19 x 2.5
24 x 1.5
24 x 2.5
27 x 1.5
27 x 2.5
37 x 1.5
37 x 2.5
Approximate Overall Diameter (mm)
16.4
18.5
17.5
19.5
18.5
20.5
22
25
22.5
25.5
25
28
Current rating (A)
10
13
9
12
9
11
8
10
8
10
7
9
Approximate Weight (kg/km)
375
545
425
615
490
700
635
915
690
1005
910
1300
Min. bending radius fixed installation (mm)
70
75
70
80
75
85
90
150
90
155
150
195
Sheath Colour
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Datasheet Ref: MC-PC-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 IEC 150/250V Fire Resistant
IEC 60092-376 - Instrumentation Cables Unarmoured - Collective Screen
NEK606 NEK606
Marine Cables to IEC 60092-376 Specification
Applicable Standards
IEC BS6883
IEEE IEEE
IEC 60092-376 IEC 60092-351 IEC 60092-350 IEC 60332 part 3 (Category A) IEC 60331-21 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228
Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Conductor Identification Pair: White / Blue with printed pair number Triple: White / Blue / Brown with printed triple number New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to IEC 60228 Class 2
(2) Mica tape:
Layer of mica tape
(3) Insulation:
XLPE Complying with IEC 60092-351
(4) Bedding:
Lapped polyester tape / filler tape
(5) Outer Sheath:
Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359
Datasheet Ref: MC-INS-CS-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250V Fire Resistant
Marine Cables to IEC 60092-376 Specification
Marine Instrumentation Unarmoured Cables - Collective Screen - Table 1/3 Cable
1x2x0.5
2x2x0.5
4x2x0.5
Approximate Overall Diameter (mm)
6
6.5
9.5
Approximate Weight (kg/km)
50
60
100
Min. bending radius fixed installation (mm)
45
50
55
Sheath Colour
Orange
Orange
Orange
7x2x0.5
10x2x0.5
14x2x0.5
11
13
14.5
150
220
270
65
80
85
Orange
Orange
Orange
19x2x0.5
24x2x0.5
1x2x0.75
2x2x0.75
17
19
8.5
10
350
450
75
120
100
115
55
60
Orange
Orange
Orange
Orange
Marine Instrumentation Unarmoured Cables - Collective Screen - Table 2/3 Cable
4x2x0.75
7x2x0.75
8x2x0.75
Approximate Overall Diameter (mm)
15.5
18.5
20
Approximate Weight (kg/km)
215
330
380
Min. bending radius fixed installation (mm)
95
115
120
Sheath Colour
Orange
Orange
Orange
10x2x0.75
12x2x0.5
14x2x0.75
19x2x0.75
24x2x0.75
23
24
25.5
29.5
33.5
480
545
620
805
1030
140
145
155
180
205
Orange
Orange
Orange
Orange
Orange
1x3x0.75
2x3x0.75
4x3x0.75
7
11
12.5
70
150
190
50
65
75
Orange
Orange
Orange
4x3x1.5
Marine Instrumentation Unarmoured Cables - Collective Screen - Table 3/3 Cable
7x3x0.75
10x3x0.75
1x2x1.5
2x2x1.5
4x2x1.5
7x2x1.5
10x2x1.5
14x2x1.5
19x2x1.5
1x3x1.5
2x3x1.5
Approximate Overall Diameter (mm)
15.5
18
8
9
13.5
16.5
20
22.5
26
9
13.5
15
Approximate Weight (kg/km)
310
440
90
130
230
370
510
690
910
100
240
320
Min. bending radius fixed installation (mm)
95
115
50
55
85
100
125
135
155
55
85
95
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Datasheet Ref: MC-INS-CS-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 IEC 150/250V Fire Resistant
IEC 60092-376 - Instrumentation Cables Unarmoured - Individual Screen
NEK606 NEK606
Marine Cables to IEC 60092-376 Specification
Applicable Standards
IEC BS6883
IEEE IEEE
IEC 60092-376 IEC 60092-351 IEC 60092-350 IEC 60332 part 3 (Category A) IEC 60331-21 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228
Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Conductor Identification Pair: White / Blue with printed pair number Triple: White / Blue / Brown with printed triple number New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to IEC 60228 Class 2
(2) Mica tape:
Layer of mica tape
(3) Insulation:
XLPE Complying with IEC 60092-351
(4) Individual Screen:
Pairs / Triples screened with plastic coated aluminium tape and a tinned copper drain wire
(5) Bedding:
Lapped polyester tape / filler tape
(6) Outer Sheath:
Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359
Datasheet Ref: MC-INS-IS-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250V Fire Resistant
Marine Cables to IEC 60092-376 Specification
Marine Instrumentation Unarmoured Cables - Individual Screen - Table 1/3 Cable
1x2x0.5
2x2x0.5
4x2x0.5
Approximate Overall Diameter (mm)
6
8.5
10
Approximate Weight (kg/km)
50
90
120
7x2x0.5
10x2x0.5
14x2x0.5
19x2x0.5
24x2x0.5
1x2x0.75
2x2x0.75
4x2x0.75
12
14
15.5
18.5
190
260
340
460
20.5
6
6.5
11.5
580
50
60
130
Min. bending radius fixed installation (mm)
40
55
60
70
90
95
115
125
40
40
65
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
19x2x0.75
24x2x0.75
1x3x0.75
2x3x0.75
4x3x0.75
7x3x0.75 16.5
Marine Instrumentation Unarmoured Cables - Individual Screen - Table 2/3 Cable
7x2x0.75
8x2x0.75
10x2x0.75
12x2x0.75
14x2x0.75
Approximate Overall Diameter (mm)
14
15
17
18
19
22
24.5
7
11.5
13
Approximate Weight (kg/km)
260
270
370
395
490
650
840
70
160
220
350
Min. bending radius fixed installation (mm)
90
95
105
110
115
135
150
45
70
80
100
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
10x2x1.5
14x2x1.5
19x2x1.5
1x3x1.5
2x3x1.5
4x3x1.5
Marine Instrumentation Unarmoured Cables - Individual Screen - Table 3/3 Cable
10x3x0.75
1x2x1.5
2x2x1.5
4x2x1.5
7x2x1.5
Approximate Overall Diameter (mm)
19
8
12
14
17.5
21
23.5
27
8.5
14
16
Approximate Weight (kg/km)
510
90
190
270
440
610
820
1020
100
260
350
Min. bending radius fixed installation (mm)
115
50
70
90
105
125
145
165
50
85
100
Sheath Colour
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Orange
Datasheet Ref: MC-INS-IS-FS
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 150/250V Flame Retardant
IEC 60092-376 - Instrumentation Cables Unarmoured - Collective Screen
NEK606
Marine Cables to IEC 60092-376 Specification
Applicable Standards
IEEE
IEC 60092-376 IEC 60092-351 IEC 60092-350 IEC 60092-359 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228
IEC
Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Conductor Identification Pair: White / Blue with printed pair number Triple: White / Blue / Red with printed triple number New harmonised core colours or project specified colours can be supplied upon special request
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to IEC 60228 Class 2
(2) Insulation:
XLPE Complying with IEC 60092-351
(3) Screen:
Aluminium polyester tape coverage 100%/ copper drain wire
(4) Outer Sheath:
Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359
Datasheet Ref: MC-INS-CS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250V Flame Retardant
Marine Cables to IEC 60092-376 Specification
Marine Instrumentation Unarmoured Cables - Collective Screen - Table 1/3 Cable
1x2x0.5
2x2x0.5
4x2x0.5
7x2x0.5
8x2x0.5
10x2x0.5
12x2x0.5
14x2x0.5
19x2x0.5
24x2x0.5
37x2x0.5
Approximate Overall Diameter (mm)
6
7
10.5
12.5
13.5
15.5
16
17.5
20
22
27
Approximate Weight (kg/km)
45
65
120
175
200
245
280
315
410
515
745
Min. bending radius fixed installation (mm)
40
45
65
75
85
95
100
105
120
135
165
Sheath Colour
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
14x2x0.75
19x2x0.75
24x2x0.75
2x3x0.75
Marine Instrumentation Unarmoured Cables - Collective Screen - Table 2/3 Cable
1x2x0.75
2x2x0.75
4x2x0.75
7x2x0.75
8x2x0.75
10x2x0.75
12x2x0.75
Approximate Overall Diameter (mm)
6.5
7.5
11.5
14
15
17
18
19
22
24.5
11
Approximate Weight (kg/km)
55
80
150
225
260
320
365
415
555
680
150
Min. bending radius fixed installation (mm)
40
45
70
85
90
105
110
115
135
150
65
Sheath Colour
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
10x2x1.5
14x2x1.5
19x2x1.5
2x3x1.5
4x3x1.5
Marine Instrumentation Unarmoured Cables - Collective Screen - Table 3/3 Cable
4x3x0.75
7x3x0.75
Approximate Overall Diameter (mm)
12
15.5
Approximate Weight (kg/km)
190
310
Min. bending radius fixed installation (mm)
70
95
Sheath Colour
Grey
Grey
10x3x0.75
2x2x1.5
4x2x1.5
7x2x1.5
18
9
13.5
16.5
20
22.5
26
13.5
15
440
130
230
370
510
690
910
240
320
105
55
85
100
120
140
155
85
90
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Datasheet Ref: MC-INS-CS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
BS6883 150/250V Flame Retardant
IEC 60092-376 - Instrumentation Cables Unarmoured - Individual Screen
NEK606
Marine Cables to IEC 60092-376 Specification
Applicable Standards
IEEE
IEC 60092-376 IEC 60092-351 IEC 60092-350 IEC 60092-359 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228
IEC
Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Conductor Identification Pair: White / Blue with printed pair number Triple: White / Blue / Red with printed triple number New harmonised core colours or project specified colours can be supplied upon special request
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor to IEC 60228 Class 2
(2) Insulation:
XLPE Complying with IEC 60092-351
(3) Individual Screen:
Pairs / Triples screened with plastic coated aluminium tape and a tinned copper drain wire
(4) Screen:
Aluminium polyester tape coverage 100%/ copper drain wire
(5) Outer Sheath:
Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359
Datasheet Ref: MC-INS-IS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
150/250V Flame Retardant
Marine Cables to IEC 60092-376 Specification
Marine Instrumentation Unarmoured Cables - Individual Screen - Table 1/3 Cable
1x2x0.5
2x2x0.5
4x2x0.5
7x2x0.5
Approximate Overall Diameter (mm)
6
9.5
11
13
Approximate Weight (kg/km)
50
95
145
220
Min. bending radius fixed installation (mm)
50
60
65
80
Sheath Colour
Grey
Grey
Grey
Grey
8x2x0.5
10x2x0.5
12x2x0.5
14x2x0.5
19x2x0.5
24x2x0.5
14
16
16.5
245
305
350
85
95
Grey
Grey
1x3x0.5
1x2x0.75
17.5
20
395
520
22.5
6
6.5
655
55
100
110
60
125
140
50
55
Grey
Grey
Grey
Grey
Grey
Grey
1x3x0.75
2x3x0.75
4x3x0.75
Marine Instrumentation Unarmoured Cables - Individual Screen - Table 2/3 Cable Approximate Overall Diameter (mm) Approximate Weight (kg/km)
2x2x0.75
4x2x0.75
7x2x0.75
8x2x0.75
10x2x0.75 12x2x0.75 14x2x0.75 19x2x0.75 24x2x0.75
10
12
14.5
15
17.5
18
19.5
22.5
23
7
11.5
13
115
180
275
310
380
440
520
680
840
70
160
220
Min. bending radius fixed installation (mm)
65
75
90
95
105
110
120
135
155
50
70
80
Sheath Colour
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
10x2x1.5
14x2x1.5
19x2x1.5
1x3x1.5
2x3x1.5
4x3x1.5
Marine Instrumentation Unarmoured Cables - Individual Screen - Table 3/3 Cable
7x3x0.75
Approximate Overall Diameter (mm)
10x3x0.75
1x2x1.5
16.5
19
8
Approximate Weight (kg/km)
350
510
90
2x2x1.5
4x2x1.5
7x2x1.5
12
14
17.5
21
23.5
27
8.5
14
16
190
270
440
610
820
1020
100
260
350
Min. bending radius fixed installation (mm)
100
120
50
75
85
110
130
145
165
50
85
95
Sheath Colour
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Datasheet Ref: MC-INS-IS-FR
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
Section 8 Offshore Fibre Optic Cables
FPAL Verify
Verified No.10049350
ABS
8
MARINE NEK606
AICI Fibre Optic Cable
(1)
Applicable Standards
(2) (3) (4)
IEEE
IEC 60332-1 IEC 60332-3-22 IEC 60754-1-2 IEC 61034-1-2
Optical cable for industrial environments. The cable is suitable
(5)
for both indoor and outdoor installation. Continiuous submergence in water is not recommended. The outer sheath
IEC
Application
is made from black UV-stabilized and weather resistant
(6)
material which is SHF1 classified, and may be exposed for shorter periods to fluids such as diesel and mineral oils. The resistance to these fluids is according to IEC60811-2-1.
Note: picture is for illustration purposes only
Construction
Specifications
(1) Central Strength Member:
Dielectric Strength Member (FRP)
(2) Tight Coating:
850 Micron Tight Buffered Optical Fibres
Fibre Colour Code: Cable Core Stranded:
EIA/TIA 598 The Fibres are Bundled Around a Central Strength Member (FRP)
(3) Strain Relief:
Water Blocking Aramid Yarns
(4) Inner Jacket:
Black LSZH, SHF1
(5) Metallic Armour:
Galvanised Steel Wire Braid (GSWB)
(6) Outer Sheath:
Black LSZH SHF1
Datasheet Ref: SC-FIBRE-AICI
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
AICI Fibre Optic Cable Specification
No. of Fibres
Tight Diameter (Micron)
Nominal O.D (mm)
Cable Weight
Tesile Strength Inst. / Oper (N)
2
850 ± 50
7.8
88
500/200
4
850 ± 50
8
98
600/240
8
850 ± 50
9
110
800/350
12
850 ± 50
10
130
1000/400
16
850 ± 50
10.5
165
1000/400
24
850 ± 50
12
190
1200/480
Mechanical & Installation Characteristics
Temp. Range
(Operation)
Temp. Range
(Installation)
-40°C to +70°C -40°C to +70°C
Temp. Range
(Storage)
-40°C to +70°C
Min. Bending radius
(Static)
10 x Ø
Min. Bending radius
(Dynamic)
20 x Ø
Max. Tensile Strength
(Installation)
(IEC 60794-1-2E1)
See Above
Crush
(IEC 60794-1-2E3)
2000 N/100mm
Impact
(IEC 60794-1-2E4)
1 Impact, 25J
Torsion
(IEC 60794-1-2E7)
± 1 turns/ 1 m
Water Tightness*
(IEC 60794-1-2E7)
<3 m/24 Hours
* Steel Wire Braid is not Water Tight
Behaviour Under Fire Conditions
Fire Resistance
IEC 60331-25
Fire Resistance
IEC 60331-25
Flame Retardant
IEC 60332-1-2
No-Fire Propagation
IEC 60332-3-22
Halogen Content
IEC 60754-1-2
Smoke Density
IEC 61034-1-2
Upgraded
750°C, 3 hours
< 1.0 dB/excess loss
1000°C, 3 hours
< 1.5 dB/excess loss
Datasheet Ref: SC-FIBRE-AICI
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
AICI Fibre Optic Cable Optical Characteristics Single Mode IEC 11801 Classification
OS1/OS2
ITU-T Type
G.652D
± 0.4 µm
Mode Field Diameter
at 1310 nm
9.0
Mode Field Diameter
at 1550 nm
10.1 ± 0.5 µm
Cladding Diameter
125.0 ± 0.7 µm
Coating Diameter (nom.)
242 ± 7 µm
Numerical Aperture Attenuation (max.)
Bending Loss (max.) 1 turns D= 30mm
0.13 (nom) at 850 nm
-
at 1300 nm
-
at 1310 nm
≤ 0.35 dB/km
at 1383 nm
≤ 0.35 dB/km
at 1460 nm
≤ 0.25 dB/km
at 1550 nm
≤ 0.21 dB/km
at 1625 nm
≤ 0.23 dB/km
at 1550 nm
≤ 0.25 dB
at 1625 nm Bandwidth
Chromatic Dispersion
Gigabit Ethernet
≤ 1.0 dB
at 850 nm
-
at 1300 nm
-
at 1285 - 1330 nm
≤ 3.0 ps/nm x km
at 1550 nm
≤ 18 ps/nm x km
at 1565 - 1625 nm
≤ 22 ps/nm x km
SX (1310 nm)
10000 m
LX (1550 nm) 10 Gigabit Ethernet
40000 m
SX (1310 nm)
10000 m
LX (1550 nm)
40000 m
Multi Mode 62.5/125
Multi Mode 50/125
IEC 11801 Classification
OM1
OM2
ITU-T Type
-
G.651
Core Diameter
62.5 ± 2.5 µm
50 ± 2.5 µm
Cladding Diameter
125.0 ± 2.0 µm
125.0 ± 2.0 µm
Coating Diameter (nom.)
242 ± 5.0 µm
242 ± 7.0 µm
Numerical Aperture Attenuation (max.)
Bending Loss (max.) 1 turns D= 75mm
0.275 ± 0.015 µm
0.200 ± 0.015 µm
at 850 nm
≤ 3.5 dB/km
≤ 2.8 dB/km
at 1300 nm
≤ 1.0 dB/km
≤ 1.0 dB/km
at 1550 nm
≤ 0.05 dB
≤ 0.5 dB
≤ 0.05 dB
≤ 0.5 dB
≥ 200 MHz x km
≥ 500 MHz x km
at 1300 nm
≥ 500 MHz x km
≥ 500 MHz x km
SX (850 nm)
275 VCLS (m)
550 VCLS (m)
LX (1300 nm)
550 Laser (m)
550 Laser (m)
SX (850 nm)
33 VCSL (m)
82 VCSL (m)
LX (1300 nm)
300 WWDM (m)
300 WWDM (m)
at 1625 nm Bandwidth
Gigabit Ethernet
10 Gigabit Ethernet
at 850 nm
Datasheet Ref: SC-FIBRE-AICI
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
MARINE NEK606
QFCI Fibre Optic Cable
Applicable Standards
IEEE
IEC 60754-1 IEC 61034-2 IEC 60331-25 IEC 60332 part 3 (Category A)
This range of cables is specially designed for use in communication and emergency systems than need to be operational during a fire. These cables are ideal for many different ap-
IEC
Application
plications including the following; PA/GA System, DP System ESD System, Security System & PLC Control System
Note: picture is for illustration purposes only
Construction
Specifications
(1) Central Strength Member:
Steel with Plastic Oversheathing
(2) Loose Tube:
Thermoplastic Material (PBT), Jelly Filled
(3) Fire Barrier:
Fire Resistant Mica/Glass Tapes
Fibre Colour Code:
EIA/TIA 598
Tubes Colour Code:
1 - Red / 2 - Green - Others White
Filler Elements:
Thermoplastic Rods
Cable Core:
Loose Tubes (and Fillers) are stranded around a steel strength member
(4) Wrapping: (5) Inner Jacket:
Black LSZH, SHF1
(6) Metallic Armour:
Galvanised Steel Wire Braid (GSWB)
(7) Outer Sheath:
Black LSZH SHF1
Datasheet Ref: SC-FIBRE-QFCI
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
QFCI Fibre Optic Cable Specification
No. of Fibres
No. of Tubes + Fillers
4
2+2
6
3+2
8
2+2
12
Tube Diameter (mm)
Nominal O.D mm
Cable Weight (kg/km)
2.5
13.5
230
2.5
13.5
230
2.5
13.5
230
3+1
2.5
13.5
230
24
4+0
2.5
13.5
230
36
3+1
3.0
14.5
250
48
4+0
3.0
14.5
250
Mechanical & Installation Characteristics
0
Temp. Range
(Operation)
Temp. Range
(Installation)
-40°C to +70°C
Temp. Range
(Storage)
-40°C to +70°C
Min. Bending radius Min. Bending radius
-40°C to +70°C
(Static)
10 x Ø
(Dynamic)
20 x Ø
Max. Tensile Strength
(Installation)
(IEC 60794-1-2E1)
1500 N
Max. Tensile Strength
(Operation)
(IEC 60794-1-2E1)
500 N
Crush
(IEC 60794-1-2E3)
3000 N/10cm
Impact
(IEC 60794-1-2E4)
20 impacts, 5J
Torsion
(IEC 60794-1-2E7)
± 1 turns/ 1 m
Immersion Test SAE 20 4h/70 ° (IEC 60811-2-1)
PASS
Immersion Test IRM 902 4h/70°
PASS
(IEC 60811-2-1)
Behaviour Under Fire Conditions
Fire Resistance
IEC 60331-25
Fire Resistance
IEC 60331-25
Flame Retardant
IEC 60332-1-2
No-Fire Propagation
IEC 60332-3-22
Halogen Content
IEC 60754-1-2
Smoke Density
IEC 61034-1-2
Upgraded
750°C, 3 hours
< 1.0 dB/excess loss
1000°C, 3 hours
< 1.5 dB/excess loss
Datasheet Ref: SC-FIBRE-QFCI
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
QFCI Fibre Optic Cable Optical Characteristics
Single Mode IEC 11801 Classification
OS1/OS2
ITU-T Type
G.652D
± 0.4 µm
Mode Field Diameter
9.0
Mode Field Diameter
10.1 ± 0.5 µm
Cladding Diameter
125.0 ± 0.7 µm
Coating Diameter (nom.)
242 ± 7 µm
Numerical Aperture Attenuation (max.)
Bending Loss (max.) 1 turns D= 30mm
0.13 (nom) at 850 nm
-
at 1300 nm
-
at 1310 nm
≤ 0.35 dB/km
at 1383 nm
≤ 0.35 dB/km
at 1460 nm
≤ 0.25 dB/km
at 1550 nm
≤ 0.21 dB/km
at 1625 nm
≤ 0.23 dB/km
at 1550 nm
≤ 0.25 dB
at 1625 nm Bandwidth
Chromatic Dispersion
Gigabit Ethernet
≤ 1.0 dB
at 850 nm
-
at 1300 nm
-
at 1285 - 1330 nm
≤ 3.0 ps/nm x km
at 1550 nm
≤ 18 ps/nm x km
at 1565 - 1625 nm
≤ 22 ps/nm x km
SX (1310 nm)
10000 m
LX (1550 nm) 10 Gigabit Ethernet
40000 m
SX (1310 nm)
10000 m
LX (1550 nm)
40000 m
Multi Mode 62.5/125
Multi Mode 50/125
IEC 11801 Classification
OM1
OM2
ITU-T Type
-
G.651
Core Diameter
62.5 ± 2.5 µm
50 ± 2.5 µm
Cladding Diameter
125.0 ± 2.0 µm
125.0 ± 2.0 µm
Coating Diameter (nom.)
242 ± 5.0 µm
242 ± 7.0 µm
Numerical Aperture Attenuation (max.)
Bending Loss (max.) 1 turns D= 75mm
0.275 ± 0.015 µm
0.200 ± 0.015 µm
at 850 nm
≤ 3.5 dB/km
≤ 2.8 dB/km
at 1300 nm
≤ 1.0 dB/km
≤ 1.0 dB/km
at 1550 nm
≤ 0.05 dB
≤ 0.5 dB
≤ 0.05 dB
≤ 0.5 dB
≥ 200 MHz x km
≥ 500 MHz x km
at 1300 nm
≥ 500 MHz x km
≥ 500 MHz x km
SX (850 nm)
275 VCLS (m)
550 VCLS (m)
LX (1300 nm)
550 Laser (m)
550 Laser (m)
SX (850 nm)
33 VCSL (m)
82 VCSL (m)
LX (1300 nm)
300 WWDM (m)
300 WWDM (m)
at 1625 nm Bandwidth
Gigabit Ethernet
10 Gigabit Ethernet
at 850 nm
Datasheet Ref: SC-FIBRE-QFCI
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
MARINE NEK606
QFCI Fibre Optic Cable MUD Resistant
Applicable Standards
IEEE
IEC 60754-1 IEC 61034-2 IEC 60331-25 IEC 60332 part 3 (Category A)
This range of cables is specially designed for use in communication and emergency systems than need to be operational during a fire. These cables are ideal for many different ap-
IEC
Application
plications including the following; PA/GA System, DP System ESD System, Security System & PLC Control System
Note: picture is for illustration purposes only
Construction
Specifications
(1) Central Strength Member:
Steel Strength Member or Glass Fiber Reinforced Plastic (FRP)
(2) Loose Tube:
Thermoplastic Material, Jelly Filled
(3) Fire Barrier:
Fire Resistant Mica/Glass Tape Applied to Each Tube
Fibre Colour Code:
EIA/TIA 598
Tubes Colour Code:
1 - Red / 2 - Green - Others White
Filler Elements:
Thermoplastic Rods, Where Needed
Cable Core:
Loose Tubes (and Fillers) are stranded around a steel strength member
(4) Wrapping: (5) Inner Jacket:
Black LSZH, SHF1
(6) Metallic Armour:
Galvanised Steel Wire Braid (GSWB)
(7) Outer Sheath 1:
LSZH SHF1
(8) Outer Sheath 2:
SHF2 Compound (MUD, Oil, Hydrocarbon Resistant and UV Stabilised)
Datasheet Ref: SC-FIBRE-QFCI-MUD
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
QFCI Fibre Optic Cable MUD Resistant Specification
No. of Fibres
No. of Tubes + Fillers
Tube Diameter (mm)
Nominal O.D mm
Cable Weight (kg/km)
12
3+1
2.5
15
290
24
4+1
2.5
15
290
Mechanical & Installation Characteristics
0
Temp. Range
(Operation)
Temp. Range
(Installation)
-40°C to +70°C -40°C to +70°C
Temp. Range
(Storage)
-40°C to +70°C
Min. Bending radius
(Static)
10 x Ø
Min. Bending radius
(Dynamic)
20 x Ø
Max. Tensile Strength
(Installation)
(IEC 60794-1-2E1)
1500 N
Max. Tensile Strength
(Operation)
(IEC 60794-1-2E1)
500 N
Crush
(IEC 60794-1-2E3)
3000 N/10cm for 15 min
Impact
(IEC 60794-1-2E4)
20 impacts, 5J
Torsion
(IEC 60794-1-2E7)
± 1 turns/ 1 m
Behaviour Under Fire Conditions
Fire Resistance
IEC 60331-25
Fire Resistance
IEC 60331-25
Flame Retardant
IEC 60332-1-2
No-Fire Propagation
IEC 60332-3-22
Halogen Content
IEC 60754-1-2
Smoke Density
IEC 61034-1-2
Upgraded
750°C, 3 hours
< 1.0 dB/excess loss
1000°C, 3 hours
< 1.5 dB/excess loss
Datasheet Ref: SC-FIBRE-QFCI-MUD
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
QFCI Fibre Optic Cable MUD Resistant Optical Characteristics Single Mode IEC 11801 Classification
OS1/OS2
ITU-T Type
G.652D
± 0.4 µm
Mode Field Diameter
at 1310 nm
9.0
Mode Field Diameter
at 1550 nm
10.1 ± 0.5 µm
Cladding Diameter
125.0 ± 0.7 µm
Coating Diameter (nom.)
242 ± 7 µm
Numerical Aperture
0.13 (nom)
Attenuation (max.)
at 850 nm
-
at 1300 nm
-
at 1310 nm
≤ 0.35 dB/km
at 1383 nm
≤ 0.35 dB/km
at 1460 nm
≤ 0.25 dB/km
at 1550 nm
≤ 0.21 dB/km
at 1625 nm
≤ 0.23 dB/km
at 1550 nm
≤ 0.25 dB
Bending Loss (max.) 1 turns D= 30mm
at 1625 nm Bandwidth
≤ 1.0 dB
at 850 nm
-
at 1300 nm
-
at 1285 - 1330 nm
≤ 3.0 ps/nm x km
at 1550 nm
≤ 18 ps/nm x km
at 1565 - 1625 nm
≤ 22 ps/nm x km
SX (1310 nm)
10000 m
Chromatic Dispersion
Gigabit Ethernet
LX (1550 nm)
40000 m
SX (1310 nm)
10000 m
LX (1550 nm)
40000 m
10 Gigabit Ethernet
Multi Mode 62.5/125
Multi Mode 50/125
IEC 11801 Classification
OM1
OM2
ITU-T Type
-
G.651
Core Diameter
62.5 ± 2.5 µm
50 ± 2.5 µm
Cladding Diameter
125.0 ± 2.0 µm
125.0 ± 2.0 µm
Coating Diameter (nom.)
242 ± 5.0 µm
242 ± 7.0 µm
Numerical Aperture Attenuation (max.)
Bending Loss (max.) 1 turns D= 75mm
0.275 ± 0.015 µm
0.200 ± 0.015 µm
at 850 nm
≤ 3.5 dB/km
≤ 2.8 dB/km
at 1300 nm
≤ 1.0 dB/km
≤ 1.0 dB/km
at 1550 nm
≤ 0.05 dB
≤ 0.5 dB
≤ 0.05 dB
≤ 0.5 dB
≥ 200 MHz x km
≥ 500 MHz x km
at 1300 nm
≥ 500 MHz x km
≥ 500 MHz x km
SX (850 nm)
275 VCLS (m)
550 VCLS (m)
LX (1300 nm)
550 Laser (m)
550 Laser (m)
SX (850 nm)
33 VCSL (m)
82 VCSL (m)
LX (1300 nm)
300 WWDM (m)
300 WWDM (m)
at 1625 nm Bandwidth
Gigabit Ethernet
10 Gigabit Ethernet
at 850 nm
Datasheet Ref: SC-FIBRE-QFCI-MUD
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
Section 9 Coaxial Cables
FPAL Verify
Verified No.10049350
ABS
9
MARINE NEK606
RG11A/U 75 Ohm Coaxial Cable
Applicable Standards
IEEE
DIN EN 13602 Cu-ETP-A...-B DIN EN 50290-2-29 IEC 60092-359 / SHF-2 IEC 60332 part 3 (Category A)
Application IEC
This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor
(2) Insulation:
Polyethylene
(3) Armour:
Bare Copper Braid
(4) Outer Sheath:
SHF2
Datasheet Ref: SC-COAX-RG11A-SHF2
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
RG11A/U 75 Ohm Coaxial Cable Electrical Characteristics
Electrical Characteristics @ 20°C Stranding mm
7/0.4
Inner Conductor Diameter mm
1.21
Insulation Diameter mm
7.25
Armour/Braid Diameter mm
8
Overall Diameter (min/max) mm
10.0/10.6
Conductor Resistance – Ohm/km
≤ 22 ≥ 10
Insulation Resistance – GOhm/km Capacitance 1 KHz – nF/m
≈ 68
Characteristic Impedance Ohm
75 ± 3
Operating Voltage V
≤ 300
Test Voltage (wire/screen)
2000V rms 50 Hz 1min
Re. Velocity of Propagation %
66
Frequency (MHz)
Attenuation dB/100m
5
1.3
10
1.8
50
4.1
100
6.1
200
9
300
11.4
500
15.5
1000
24
2000
39.5
2500
47.5
Other Characteristics
Other Characteristics RoHS Compliant Permissable Temperature Range °C
- 40 up to + 105
Min. Bending radius allowed:
8 x OD repeated, 4 x single
Weight kg/km
145
Datasheet Ref: SC-COAX-RG11A-SHF2
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com
FPAL Verify
Verified
No.10049350
ABS
MARINE NEK606
RG58C/U 50 Ohm Coaxial Cable
Applicable Standards
IEEE
DIN EN 13602 Cu-ETP-R...-B DIN EN 50290-2-23 IEC 60092-359 / SHF1-1 IEC 60332 part 3 (Category A)
Application IEC
This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Tinned Stranded Copper Conductor
(2) Insulation:
Polyethylene
(3) Armour:
Tinned Copper Braid
(4) Outer Sheath:
LSZH SHF1
Datasheet Ref: SC-COAX-RG58C-SHF1
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
RG58C/U 50 Ohm Coaxial Cable Electrical Characteristics
Electrical Characteristics @ 20°C
Frequency (MHz)
Attenuation dB/100m
50
12
100
17
200
27
300
34
Stranding mm
19/0.19
Inner Conductor Diameter mm
0.93
Insulation Diameter mm
2.85
Armour/Braid Diameter mm
3.4
Overall Diameter (min/max) mm
4.80/5.10
Conductor Resistance – Ohm/km Insulation Resistance – GOhm/km
≤ 37 ≥ 10
Capacitance 1 KHz – nF/m
≈ 105
500
41
Characteristic Impedance Ohm
50 ± 2
1000
65
Operating Voltage V
≤ 300
Test Voltage (wire/screen)
2000V rms 50 Hz 1min
2000
95
Re. Velocity of Propagation %
66
2500
110
Other Characteristics
Other Characteristics RoHS Compliant Permissable Temperature Range °C
- 25 up to + 80
Min. Bending radius allowed:
10 x OD repeated, 5 x single
Weight kg/km
39
Datasheet Ref: SC-COAX-RG58C-SHF1
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com
FPAL Verify
Verified
No.10049350
ABS
MARINE NEK606
RG59B/U 75 Ohm Coaxial Cable
Applicable Standards
IEEE
DIN EN 13602 Cu-ETP-A... DIN EN 50290-2-23 IEC 60092-359 / SHF-2 IEC 60332 part 3 (Category A)
Application IEC
This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Solid Bare Copper Conductor
(2) Insulation:
Polyethylene
(3) Armour:
Bare Copper Braid
(4) Outer Sheath:
SHF2
Datasheet Ref: SC-COAX-RG59B-SHF2
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
RG59B/U 75 Ohm Coaxial Cable Electrical Characteristics
Electrical Characteristics @ 20°C
Frequency (MHz)
Attenuation dB/100m
50
7.8
100
11.2
200
16.3
Inner Conductor Diameter mm
0.6
Insulation Diameter mm
3.7
Armour/Braid Diameter mm
4.3
Overall Diameter (min/max) mm
5.80/6.20
Conductor Resistance – Ohm/km
300
20.5
Insulation Resistance – GOhm/km
≤ 64 ≥ 10
500
26.7
Capacitance 1 KHz – nF/m
≈ 67
Characteristic Impedance Ohm
75 ± 3
1000
39.5
Operating Voltage (peak) V
≤ 100
2000
59.4
Test Voltage (wire/screen)
2000V rms 50 Hz 1min
2500
67.3
Other Characteristics
Other Characteristics RoHS Compliant Permissable Temperature Range °C
- 40 up to + 80
Min. Bending radius allowed:
10 x OD repeated, 5 x single
Weight kg/km
53
Datasheet Ref: SC-COAX-RG59B-SHF2
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
MARINE NEK606
RG213/U 50 Ohm Coaxial Cable
Applicable Standards
IEEE
DIN EN 13602 Cu-ETP-R... DIN EN 13602 Cu-ETP-A... DIN EN 50290-2-23 IEC 60092-359 / SHF-2 IEC 60332 part 3 (Category A)
Application IEC
This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Bare Stranded Copper Conductor
(2) Insulation:
Polyethylene
(3) Armour:
Bare Copper Braid
(4) Outer Sheath:
SHF2
Datasheet Ref: SC-COAX-RG213-SHF2
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
RG213/U 50 Ohm Coaxial Cable Electrical Characteristics
Frequency (MHz)
Electrical Characteristics @ 20°C Stranding mm
7/0.75
Inner Conductor Diameter mm
2.25
Insulation Diameter mm
7.25
Armour/Braid Diameter mm
8
Overall Diameter (min/max) mm
10.1/10.5
Insulation Resistance – GOhm/km
≤ 6.2 ≥ 10
Capacitance 1 KHz – nF/m
≈ 101
Characteristic Impedance Ohm
50 ± 2
Operating Voltage V
≤ 250
Test Voltage (wire/screen)
1500V rms 50 Hz 1min
Conductor Resistance – Ohm/km
Attenuation dB/100m
100
7.7
200
11.1
300
13.8
400
16.1
500
18.2
1000
27
1300
31
2000
40
2500
46
Other Characteristics
Other Characteristics RoHS Compliant Permissable Temperature Range °C
- 40 up to + 80
Min. Bending radius allowed:
10 x OD repeated, 5 x single
Weight kg/km
160
Datasheet Ref: SC-COAX-RG213-SHF2
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
MARINE NEK606
RG213/U 50 Ohm Coaxial Cable
Applicable Standards
IEEE
DIN EN 13602 Cu-ETP-R... DIN EN 13602 Cu-ETP-A... DIN EN 50290-2-23 IEC 60092-359 / SHF-2 IEC 60332 part 3 (Category A)
Application IEC
This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Bare Stranded Copper Conductor
(2) Insulation:
Polyethylene
(3) Armour:
Bare Copper Braid
(4) Outer Sheath:
SHF2
Datasheet Ref: SC-COAX-RG213-SHF2
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
RG213/U 50 Ohm Coaxial Cable Electrical Characteristics
Frequency (MHz)
Electrical Characteristics @ 20°C Stranding mm
7/0.75
Inner Conductor Diameter mm
2.25
Insulation Diameter mm
7.25
Armour/Braid Diameter mm
8
Overall Diameter (min/max) mm
10.1/10.5
Insulation Resistance – GOhm/km
≤ 6.2 ≥ 10
Capacitance 1 KHz – nF/m
≈ 101
Characteristic Impedance Ohm
50 ± 2
Operating Voltage V
≤ 250
Test Voltage (wire/screen)
1500V rms 50 Hz 1min
Conductor Resistance – Ohm/km
Attenuation dB/100m
100
7.7
200
11.1
300
13.8
400
16.1
500
18.2
1000
27
1300
31
2000
40
2500
46
Other Characteristics
Other Characteristics RoHS Compliant Permissable Temperature Range °C
- 40 up to + 80
Min. Bending radius allowed:
10 x OD repeated, 5 x single
Weight kg/km
160
Datasheet Ref: SC-COAX-RG213-SHF2
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
MARINE NEK606
RG214/U 50 Ohm Coaxial Cable
Applicable Standards
IEEE
DIN EN 13602 Cu-ETP-R... DIN EN 13602 Cu-ETP-A... DIN EN 50290-2-23 IEC 60092-359 / SHF-1 IEC 60332 part 3 (Category A)
Application IEC
This range of cables is designed for use in fixed installation in most areas and on open deck in ships
Note: picture is for illustration purposes only
Construction
Specifications
(1) Conductor:
Stranded Silvered Copper Conductor
(2) Insulation:
Polyethylene
(3) Armour:
Silvered Copper Braid
(4) Armour:
Silvered Copper Braid
(5) Outer Sheath:
LSZH SHF1
Datasheet Ref: SC-COAX-RG214-SHF1
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
RG214/U 50 Ohm Coaxial Cable Electrical Characteristics
Electrical Characteristics @ 20°C Stranding mm
7/0.75
Inner Conductor Diameter mm
2.25
Insulation Diameter mm
7.25
Armour/Braid Diameter mm
7.9
Armour/Braid Diameter mm
8.5
Overall Diameter (min/max) mm
10.5/11.1
Conductor Resistance – Ohm/km Insulation Resistance – GOhm/km
≤ 6.2 ≥ 10
Operating Voltage (peak) V
≤ 250
Characteristic Impedance Ohm Capacitance 800 Hz – pF/m Relative Velocity of Propagation %
66
Test Voltage (wire/screen)
5kV rms 50 Hz 1min
Frequency (MHz)
Attenuation dB/100m
100
6.9
200
10
300
12.5
400
15
500
16.8
1000
25
50 ± 2
1300
29.8
≈ 101
2000
41.6
2500
49.6
Other Characteristics
Other Characteristics RoHS Compliant Permissable Temperature Range °C
- 25 up to + 80
Min. Bending radius allowed:
10 x OD repeated, 5 x single
Weight kg/km
191
Datasheet Ref: SC-COAX-RG214-SHF1
INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com
www.interkab.com FPAL Verify
Verified
No.10049350
ABS
Aberdeen Head Office
Middle East Regional Office Dubai
CIS Regional Office Kazakhstan
INTERKAB House Links PLace Aberdeen AB11 5DY
INTERKAB 1901 Grosvenor Business Tower TECOM P.O. Box 123560 Dubai
INTERKAB Republic of Kazakhstan Atyrau, Azattyk Avenue, bid. 48 Business Centre ‘Premier Atyrau’ 7-floor
Tel 0044 (0)1224 595 640 Fax 0044 (0)1224 594 416
Tel 00971 43746808 Fax 00971 43746806
Tel 007 (8) 7122 251197 Fax 007 (8) 7122 251197
www.interkab.com DISCLAIMER All drawings, data and narrative and information contained within this catalogue is for guidance only and provided without warranty.