INTERKAB Product Catalogue

Page 1

Offshore & Marine Cable Catalogue


INTERKAB Offshore and Marine Publication Contents Introduction to Your Local and International Cable Partner What We Do Company Details Interkab Offshore Product Range UKOOA Instrumentation, Power and Control Cable Coding IEC Standards and Tests Norwegian and International Marine Specification Cables Materials – Abbreviations – Code Designations Index

FPAL Verify

Verified

No.10049350

ABS


INTERKAB Introduction to Your Local and International Cable Partner INTERKAB is the brand name of International Cable Management, a privately owned group of companies, with its headquarters based in Aberdeen. It is a leading service company in the management and supply of a diverse range of Electrical Cables including power, control, instrument, fibre optic and underwater, together with associated electrical products, to the global oil and gas industry. The company has built a strong and distinctive reputation with a strong foundation including the management team which has been associated with both the OGP industry and its products since the early days of the North Sea, some 40 years.

FPAL Verify

Verified

No.10049350

ABS


What We Do INTERKAB is both local and international, and operates from key oil and gas hubs across the globe. The company operates three distinct divisions across all its operations: Projects; Distribution and Exports. Projects INTERKAB and its employees have a wealth of knowledge and success in managing major Greenfield and Brownfield projects both offshore and onshore, firstly in the North Sea in the early 80s and more recently in China, Iraq and Russia. After-sales service through the life of the project duration operation is standard practice. Distribution and Exports INTERKAB provide a 24/7 service to the industry in supporting clients daily maintenance, operational and repair and urgent requirements from our stock or alternatively we source. If products require to be manufactured, we provide a quick delivery service of 4-6 weeks, and in some instances shorter delivery times. Commitment to customer service and to go the extra mile if need be is common practice in INTERKAB. BS EN ISO 9001 INTERKAB is assessed and approved to the latest BS EN ISO standard, as too are our manufacturers.

FPAL Verify

Verified

No.10049350

ABS


INTERKAB Company Details INTERKAB House Links Place Aberdeen AB11 5DY Tel 44 1224 595640 Fax 44 1224 594416 e-mail: sales@interkab.com website: www.interkab.com

FPAL Verify

Verified

No.10049350

ABS


INTERKAB Offshore Product Range INTERKAB stock and supply a broad range of offshore products across a range of International standards. These products are primarily used in Offshore and marine installations including Production platforms (fixed and floating); Drilling Rigs and Drilling Ships; FPSO & FSO Vessels and other offshore and marine equipment. Our offshore product range includes: LV Power and Control Instrumentation Data Communications CCTV Medium Voltage Subsea Underwater Composite Cables Network Cable Optical Fibre High Temperature

Offshore Specifications BS6883 | BS7917 | NEK606 | IEC61892-4 | IEC60092 | XI | XAI |IEEE 45 INTERKAB is also vastly experienced in contract manufacturing client or project specific cables.

Onshore Cables and Electrical products and accessories INTERKAB supplies the full range of products to meet companies’ onshore requirements for both the oil and gas industry and other associated industries.

FPAL Verify

Verified

No.10049350

ABS


UKOOA Instrumentation, Power and Control Cable Coding W 1st Character

Fire Performance and Voltage Rating

2nd Character

Cable Construction

3rd Character

No. of Cores, Pairs, Triples and Quads

4th and 5th Characters

Conductor Cross Sectional Areas

B

3

02

1st Character

Type

Voltage

Type

Voltage

F

Fire resistant, reduced halogen

150/250V M

Flame retardant, reduced halogen

G

Fire resistant, LSF

150/250V N

Flame retardant, reduced halogen

1.9/3.3kV

H

Flame retardant, reduced halogen

8.7/15kV P

Flame retardant, reduced halogen

6.35/11kV

J

Flame retardant, reduced halogen

150/250V M

Flame retardant, LSF

600/1000V

K

Flame retardant, LSF

150/250V N

Fire resistant, reduced halogen

600/1000V

L

Flame retardant, reduced halogen

Fire resistant, LSF

600/1000V

600/1000V P

2nd Character

3.8/6.6kV

3rd Character

Basic Construction

Sheath Colour

Armour

A

Flame retardant

Black (600/1000V), Red (HV)

B

Flame retardant

C

Screen

1

Single Core

K

12 pair

Bronze Braid

2

2 Core

L

20 pair

Black (600/1000V), Red (HV)

GSWB

3

3 Core

M

27 pair

Fire resistant

Black (600/1000V)

Bronze Braid

4

4 Core

N

37 pair

D

Fire resistant

Black (600/1000V)

GSWB

7

7 Core

R

1 triple

E

Flame retardant

Green/Yellow

None None

A

12 Core

S

3 triple

F

Flame retardant

Black

None None

B

19 Core

T

7 triple

G

Flame retardant

Light Blue

GSWB

Collective

C

27 Core

U

12 triple

H

Flame retardant

Light Blue

GSWB

Individual

D

37 Core

X

1 quad

J

Flame retardant

Grey

GSWB

Collective

F

1 pair

Y

3 quad

K

Flame retardant

Grey

GSWB

Individual

H

3 pair

Z

7 quad

L

Fire resistant

Light Blue

GSWB

Collective

J

7 pair

M

Fire resistant

Light Blue

GSWB

Individual

N

Fire resistant

Grey

GSWB

Collective

P

Fire resistant

Grey

GSWB

Individual

Y

Flame retardant

Orange

GSWB

Co-axial

4th and 5th Characters 00

0.75 mm2

Flexible (class 5) stranded tinned copper cores

50

50.0 mm2

Stranded tinned copper cores

01

1.0 mm

Flexible (class 5) stranded tinned copper cores

70

70.0 mm2

Stranded tinned copper cores

02

1.5 mm2

Flexible (class 5) stranded tinned copper cores

95

95.0 mm2

Stranded tinned copper cores

03

2.5 mm2

Stranded tinned copper cores

OA

120.0 mm2

Stranded tinned copper cores

04

4.0 mm2

Stranded tinned copper cores

OB

150.0 mm2

Stranded tinned copper cores

05

4.0 mm2

Single solid tinned copper cores (special)

OC

185.0 mm2

Stranded tinned copper cores

06

6.0 mm2

Stranded tinned copper cores

OD

240.0 mm2

Stranded tinned copper cores

10

10.0 mm2

Stranded tinned copper cores

OE

300.0 mm2

Stranded tinned copper cores

16

16.0 mm2

Stranded tinned copper cores

OF

400.0 mm2

Stranded tinned copper cores

25

25.0 mm2

Stranded tinned copper cores

OG

500.0 mm2

Stranded tinned copper cores

35

35.0 mm2

Stranded tinned copper cores

OH

630.0 mm2

Stranded tinned copper cores

2

FPAL Verify

Verified

No.10049350

ABS


IEC Standards and tests

Page 1 of 5

FPAL Verify

Verified

No.10049350

ABS


Page 2 of 5

FPAL Verify

Verified

No.10049350

ABS


Page 3 of 5

These cable types have Mica tape applied around the conductors which is then insulated with a heat-resistant compound and have an outer sheathing of a halogen-free material and have a metal braid armour between the insulation and outer sheathing.

FPAL Verify

Verified

No.10049350

ABS


Page 4 of 5

FPAL Verify

Verified

No.10049350

ABS


Page 5 of 5

Offshore Cables

FPAL Verify

Verified

No.10049350

ABS


Norwegian and International Marine Specification Cables Standards and tests Norwegian Specification offshore topside cables are designed in accordance with the following major IEC-standards and tests Standard

Title of standard

NEK 606:2004

Cables for offshore installations halogen-free and/or mud resistant.

IEC 60092-3

Electrical installations in ships.

IEC 60092-350

Low voltage shipboard power cables. General construction and test requirements.

IEC 60092-351

Insulating materials of shipboard power cables.

IEC 60092-352

Electrical installations in ships choice and installation of cables for low voltage power systems.

IEC 60092-353

Single and multicore non-radial field power cables with extruded solid insulation for rated voltages 1kV and 3kV.

IEC 60092-359

Sheathing materials for shipboard power and telecommunication cables.

IEC 60092-376:2003 Electrical installations in ships – Cables for control instrumentation circuits 150/250V (300V). IEC 60331-31

Tests for electric cables under fire conditions – Circuit integrity procedure and requirements for fire with shock – Cables of rated voltage up to and including 0.6/1kV.

IEC 60332-1

Tests on electric cables under fire conditions. Test on a single vertical insulated wire or cable.

IEC 60332-3-22

Tests on electric cables under fire conditions. Tests for vertical flame spread of vertically-mounted bunched wires of cables – Category A.

IEC 60754-1/2

Test on gases evolved during combustion of electric cables. Part 1: Determination of the halogen acid gas. Part 2: Determination of the degree of acidity during the combustion of materials taken from electric cables by measuring pH and conductivity.

IEC 61034-2

Measurement of smoke density of cables burning under defined conditions.

CSA C22.2 No 39-05

Thermoset Insulated Wires and Cables – Wiring Products. Clause 6.4.4: Low Temperature Flexibility (-40° C) Clause 6.4.5: Low Temperature Impact (-40° C)

FPAL Verify

Verified

No.10049350

ABS


NEK 606 Materials – Abbreviations – Code Designations

1st Letter

Insulation Materials Fire resistant tape + insulation (Halogen-free)

B

Ethylene Propylene rubber – EPR

R

Cross-linked polyethylene XLPE

T

Thermoplastic compound (Halogen-free)

I

Halogen-free thermoset compound EMA or EVA

U

Fibre, tight buffered

A

Fibre in loose tube

Q

2nd Letter

Bedding/ Inner covering Inner sheath

Bedding/Inner covering or taping (Halogen-free)

F

Screen (poss. with PE or PP)

Y

3rd Letter 4th Letter Armour/ screen

Aluminium (laminated to outer jacket)

L

No armour

X

Copper wire braid (Tinned or bare)

O

Strength member of yarn

A

Galvanised steel wire braid

C

Thermoplastic compound (Halogen-free) SHF1

Outer sheath

I

I

Halogen-free thermoset compound, SHF2

U

Halogen-free mud resistant thermoset compound, SHF Mud

U

Halogen-free mud resistant thermoplastic

B1)

1)

QFCB Cables only

FPAL Verify

Verified

No.10049350

ABS


Index

FPAL Verify

Verified No.10049350

ABS


CATALOGUE INDEX British Specification BS6883 / BS7917 SECTION 1 Offshore Instrumentation Cables BS6883 Flame Retardant BS6883 / BS7917 Fire Resistant SECTION 2 Offshore Power & Control Cables BS6883 Flame Retardant BS6883 / BS7917 Fire Resistant SECTION 3 Medium Voltage Power Cables BS6883 Flame Retardant Norwegian Specification NEK 606 SECTION 4 Offshore Instrumentation Cables RFOU Flame Retardant BFOU Fire Resistant SECTION 5 Offshore Power & Control Cables RFOU Flame Retardant BFOU Fire Resistant SECTION 6 Medium Voltage Power Cables RFOU Flame Retardant BFOU Fire Resistant Marine Cables SECTION 7 Instrument Cables Flame Retardant Fire Resistant SECTION 8 Power & Control Cables Flame Retardant Fire Resistant SECTION 9 Offshore Fibre Optic Cables

FPAL Verify

Verified No.10049350

ABS


Section 1 Offshore Instrumentation Cables to BS6883 Specification

FLAME RETARDANT

FPAL Verify

Verified No.10049350

ABS

1


BS6883

Offshore Instrumentation Cables to BS6883 Specification NEK606

150/250V Flame Retardant

Pairs/Triples/Quads Armoured Cables – Collectively Screened:

Applicable Standards

IEEE

BS6883 / IEC 60092-359 BS7655 BS EN 10257-1 IEC 60332 part 3 (Category A, B & C) IEC-60228 Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS6360

This range of cables is designed for use in fixed wiring in ships and offshore units, e.g. safety and emergency lighting, fire pumps, shut down systems, communication systems, gas detectors, and alarms. These cables are ideal for occupied areas including accommodation facilities, control rooms and computer suites.

IEC

Application

Conductor Identification Single Pair: Black and White Multi-Pair: Black and White Numbered Pairs Triples: Black, White and Red Numbered Triples Quads: Black, White, Red and Blue Numbered Quads New harmonised core colours or project specified colours can be supplied upon special request

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to BS6360 Class 2 (Flexible Class 5 conductors available upon request)

(2) Insulation:

EPR Complying with BS7655 GP4

(3) Collective Screen:

Aluminium Mylar Tape Screen in contact with Tinned Copper drain wire Note: A suitable tape or tapes may be applied over the collectively screened pairs, triples, or quads

(4) Bedding:

EVA - SW4 Thermo set Rubber Compound Complying with BS7655 (UKOOA type KG/KJ) OR CSP - SW2 Thermo set Rubber Compound Complying with BS7655 (UKOOA type JG/JJ)

(5) Armour:

Galvanised Steel Wire Braid to BS EN 10257-1 Note: A suitable tape or tapes may be applied under and/or over the braid

(6) Outer Sheath:

EVA - SW4 Thermo set Rubber Compound Complying with BS7655 (UKOOA type KG/KJ) OR CSP - SW2 Thermo set Rubber Compound Complying with BS7655 (UKOOA type JG/JJ)

Datasheet Ref: OFS-BS-INS-CS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250V Flame Retardant

Offshore Instrumentation Cables to BS6883 Specification

Pairs/Triples/Quads Collectively Screened Armoured Cables - Table 1/3 Cable

1x2x0.75

2x2x0.75

3x2x0.75

7x2x0.75

12x2x0.75

20x2x0.75

1x3x0.75 (Ind. Screen)

3x3x0.75

7x3x0.75

Stranding mm

24/0.20

24/0.20

24/0.20

24/0.20

24/0.20

24/0.20

24/0.20

24/0.20

24/0.20

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.2

1.2

1.2

1.4

1.6

1.8

1

1.3

1.5

Diameter over Inner Sheath (min/max) mm

7.6/9.6

11.6/13.6

12.6/14.5

16.6/18.7

21.7/24.2

27.3/30.1

7.9/9.9

14.2/16.2

19.2/21.2

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.3

0.45

0.3

0.3

0.3

Thickness of Outer Sheath mm

1.25

1.4

1.4

1.7

1.7

2

1.25

1.2

1.4

Overall Diameter (min/max) mm

11.9/13.9

17.3/19.3

16.7/19.0

20.9/23.8

26.4/29.5

33.3/37.1

12.5/14.5

19.4/21.4

25.0/27.0

Gland Size

O

A

A

B

C

C2

O

B

C

Weight kg/km

200

385

468

706

1030

1662

285

680

1325

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

Maximum L/R ratio

21

21

21

21

21

21

21

21

21

Maximum LOOP self inductance mH/km

0.86

0.86

0.86

0.86

0.86

0.86

0.86

0.86

0.86

Maximum Mutual Capacitance – pF/m

104

88

88

88

88

88

92

88

88

DC Resistance @ 20°c – OHMS/km

25.3

25.3

25.3

25.3

25.3

25.3

25.3

25.3

25.3

AC Resistance @ 90°c – OHMS/km

32.3

32.3

32.3

32.3

32.3

32.3

32.3

32.3

32.3

Sheath Colour

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

KGH00

KGJ00

KGK00

KGL00

KGR00

KGS00

KGT00

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

KJH00

KJJ00

KJK00

KJL00

KJR00

KJS00

KJT00

KGF00 UKOOA Codes (EVA)

UKOOA Codes (CSP)

(Blue) KJF00

-

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

JGF00

JGH00

JGJ00

JGK00

JGL00

JGR00

JGS00

JGT00

(Blue) JJF00

-

(Grey)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

JJH00

JJJ00

JJK00

JJL00

JJR00

JJS00

JJT00

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

Pairs/Triples/Quads Collectively Screened Armoured Cables - Table 2/3 Cable

12x3x0.75

1x2x1.0 (Ind.Screen)

1x3x1.0 (Ind.Screen)

1x4x1.0 (Ind.Screen)

1x2x1.5

2x2x1.5

3x2x1.5

5x2x1.5

7x2x1.5

Stranding mm

24/0.20

32/0.20

32/0.20

32/0.20

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.7

1

1.1

1.1

1.1

1.2

1.3

1.4

1.4

Diameter over Inner Sheath (min/max) mm

26.1/28.1

8.2/10.2

8.7/10.7

10.0/12.0

8.7/9.8

12.8/14.0

14.4/16.0

17.5/19.1

19.0/23.7 0.3

Diameter of Armour/Braid mm

0.45

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Thickness of Outer Sheath mm

1.7

1

1.1

1.2

1.2

1.4

1.4

1.6

1.6

Overall Diameter (min/max) mm

33.6/35.6

12.4/14.4

13.0/15.0

14.0/16.0

12.7/14.3

16.4/18.0

18.8/20.8

22.2/24.6

23.7/26.2

Gland Size

C2

O

O

O

O

A

B

B

C

Weight kg/km

2106

180

300

180

297

505

593

826

929

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

Maximum L/R ratio

21

27

27

27

38

38

38

38

38

Maximum LOOP self inductance mH/km

0.86

0.819

0.819

0.819

0.778

0.778

0.778

0.778

0.778

Maximum Mutual Capacitance – pF/m

88

115

101

101

128

105

105

105

105

DC Resistance @ 20°c – OHMS/km

25.3

18.6

18.6

18.6

12.4

12.4

12.4

12.4

12.4

AC Resistance @ 90°c – OHMS/km

32.3

23.7

23.7

23.7

15.9

15.9

15.9

15.9

15.9

Sheath Colour

Grey/Blue

Grey/ Blue

Grey/ Blue

Grey/ Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

KGU00

KGF01

KGR01

KGX01

KGF02

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

KJU00

KJF01

KJR01

KJX01

KJF02

UKOOA Codes (EVA)

UKOOA Codes (CSP)

KGH02 -

(Blue) KJH02

KGJ02 -

(Blue) KJJ02

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

JGU00

JGF01

JGR01

JGX01

JGF02

JGH02

JGJ02

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

JJU00

JJF01

JJR01

JJX01

JJF02

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

-

(Blue) JJH02 (Grey)

-

(Blue) JJJ02 (Grey)

Datasheet Ref: OFS-BS-INS-CS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250V Flame Retardant

Offshore Instrumentation Cables to BS6883 Specification

Pairs/Triples/Quads Collectively Screened Armoured Cables - Table 3/3 Cable

10x2x1.5

12x2x1.5

20x2x1.5

1x3x1.5

3x3x1.5

5x3x1.5

7x3x1.5

12x3x1.5

1x2x2.5

Stranding mm

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.67

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.7

1.7

1.9

1.1

1.3

1.5

1.5

1.8

1.1

Diameter over Inner Sheath (min/max) mm

24.2/26.4

25.0/27.2

31.5/34.2

9.2/10.3

17.9/19.6

19.0/21.0

24.1/26.3

32.6/35.4

9.8/11.8

Diameter of Armour/Braid mm

0.3

0.45

0.45

0.3

0.3

0.3

0.3

0.45

0.3

Thickness of Outer Sheath mm

1.9

1.9

2.1

1.2

1.5

1.6

1.7

2

1.2

Overall Diameter (min/max) mm

29.5/32.6

31.0//34.2

38.1/41.7

13.2/14.8

22.4/24.9

25.0/27.0

29.0/32.0

38.9/42.5

14.1/16.1

Gland Size

C

C2

D

O

B

C

C

D

A

Weight kg/km

1343

1510

2287

304

760

928

1262

2148

320

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

Maximum L/R ratio

38

38

38

38

38

38

38

38

58

Maximum LOOP self inductance mH/km

0.778

0.778

0.778

0.778

0.778

0.778

0.778

0.778

0.731

Maximum Mutual Capacitance – pF/m

105

105

105

111

105

105

105

105

148

DC Resistance @ 20°c – OHMS/km

12.4

12.4

12.4

12.4

12.4

12.4

12.4

12.4

7.71

AC Resistance @ 90°c – OHMS/km

15.9

15.9

15.9

15.9

15.9

15.9

15.9

15.9

9.83

Sheath Colour

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

KGK02

KGL02

KGR02

KGS02

KGT02

KGU02

KGF03

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

KJK02

KJL02

KJR02

KJS02

KJT02

KJU02

KJF03

UKOOA Codes (EVA)

UKOOA Codes (CSP)

-

-

-

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

JGK02

JGL02

JGR02

JGS02

JGT02

JGU02

JGF03

(Blue)

(Blue)

(Blue)

(Blue)

JJK02

JJL02

JJR02

JJS02

(Grey)

(Grey

(Grey)

(Grey)

-

(Blue)

(Blue)

(Blue)

JJT02

JJU02

JJF03

(Grey)

(Grey)

(Grey)

Datasheet Ref: OFS-BS-INS-CS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883

Offshore Instrumentation Cables to BS6883 Specification NEK606

150/250V Flame Retardant

Pairs/Triples/Quads Armoured Cables – Individually Screened:

Applicable Standards

IEEE

BS6883 / IEC 60092-359 BS7655 IEC 60332 part 3 (Category A, B & C) IEC-60228 Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS6360

Application IEC

This range of cables is designed for use in fixed wiring in ships and offshore units, e.g. safety and emergency lighting, fire pumps, shut down systems, communication systems, gas detectors, and alarms. These cables are ideal for occupied areas including accommodation facilities, control rooms and

Conductor Identification Single Pair: Black and White Multi-Pair: Black and White Numbered Pairs Triples: Black, White and Red Numbered Triples Quads: Black, White, Red and Blue Numbered Quads New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to BS6360 Class 2 (Flexible Class 5 conductors available upon request)

(2) Insulation:

EPR Complying with BS7655 GP4

(3) Individual Screen:

Aluminium Mylar Tape Screen in contact with Tinned Copper drain wire Note: A suitable tape or tapes may be applied over the collectively screened pairs, triples, or quads

(4) Bedding:

EVA - SW4 Thermo set Rubber Compound Complying with BS7655 (UKOOA type KG/KJ) OR CSP - SW2 Thermo set Rubber Compound Complying with BS7655 (UKOOA type JG/JJ)

(5) Armour:

Galvanised Steel Wire Braid to BS EN 10257-1 Note: A suitable tape or tapes may be applied under and/or over the braid

(6) Outer Sheath:

EVA - SW4 Thermo set Rubber Compound Complying with BS7655 (UKOOA type KG/KJ) OR CSP - SW2 Thermo set Rubber Compound Complying with BS7655 (UKOOA type JG/JJ)

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

Datasheet Ref: OFS-BS-INS-IS-FR

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250V Flame Retardant

Offshore Instrumentation Cables to BS6883 Specification

Pairs/Triples/Quads Individually Screened Armoured Cables - Table 1/3 Cable

1x2x0.75

2x2x0.75

3x2x0.75

7x2x0.75

12x2x0.75

20x2x0.75

1x3x0.75

3x3x0.75

7x3x0.75 24/0.20

Stranding mm

24/0.20

24/0.20

24/0.20

24/0.20

24/0.20

24/0.20

7/0.53

24/0.20

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.2

1.2

1.2

1.4

1.6

1.8

1

1.3

1.5

Diameter over Inner Sheath (min/max) mm

7.6/9.6

8.6/10.4

12.6/14.5

16.9/19.0

21.3/23.7

27.8/30.7

7.9/9.9

14.2/16.2

19.7/22.1

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.3

0.45

0.3

0.3

0.3

Thickness of Outer Sheath mm

1.25

1.4

1.4

1.6

1.8

2

2

1.5

1.7

Overall Diameter (min/max) mm

11.9/13.9

12.4/14.3

16.7/19.0

21.4/24.3

26.1/29.2

33.8/37.8

12.5/14.5

18.6/20.9

24.4/27.4

Gland Size

O

O

A

B

C

C2

O

B

C

Weight kg/km

200

287

549

919

1380

1680

285

699

1172

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

Maximum L/R ratio

21

21

21

21

21

21

21

21

21

Maximum LOOP self inductance mH/km

0.86

0.86

0.86

0.86

0.86

0.86

0.86

0.86

0.86

Maximum Mutual Capacitance – pF/m

104

104

104

104

104

104

92

92

92

DC Resistance @ 20°c – OHMS/km

25.3

25.3

25.3

25.3

25.3

25.3

25.3

25.3

25.3

AC Resistance @ 90°c – OHMS/km

32.3

32.3

32.3

32.3

32.3

32.3

32.3

32.3

32.3

Sheath Colour

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

KHH00

KHJ00

KHK00

KHL00

KHR00

KHS00

KHT00

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

KKH00

KKJ00

KKK00

KKL00

KKR00

KKS00

KKT00

KHF00 UKOOA Codes (EVA)

UKOOA Codes (CSP)

(Blue) KKF00

-

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

JHF00

JHH00

JHJ00

JHK00

JHL00

JHR00

JHS00

JHT00

(Blue) JKF00

-

(Grey)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

JKH00

JKJ00

JKK00

JKL00

JKR00

JKS00

JKT00

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

Pairs/Triples/Quads Individually Screened Armoured Cables - Table 2/3 Cable

12x3x0.75

1x2x1.0

1x3x1.0

1x4x1.0

1x2x1.5

2x2x1.5

3x2x1.5

5x2x1.5

7x2x1.5 7/0.53

Stranding mm

24/0.20

32/0.20

32/0.20

32/0.20

7/0.53

7/0.53

7/0.53

7/0.53

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.7

1

1.1

1.1

1.1

1.1

1.3

1.4

1.5

Diameter over Inner Sheath (min/max) mm

24.4/27.1

8.2/10.2

8.7/10.7

9.0/11.0

8.9/9.9

14.6/16.1

15.2/16.8

18.8/20.5

20.9/23.0

Diameter of Armour/Braid mm

0.45

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Thickness of Outer Sheath mm

2

1

1.1

1.2

1.2

1.2

1.5

1.6

1.7

Overall Diameter (min/max) mm

30.4/34.1

12.4/14.4

13.0/15.0

14.0/16.0

13.1/15.1

19.0/21.1

19.7/22.1

23.5/26.0

25.9/28.5

Gland Size

C2

O

O

O

O

B

B

B

C

Weight kg/km

1982

262

273

300

260

591

697

983

1181

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

Maximum L/R ratio

21

27

27

27

38

38

38

38

38

Maximum LOOP self inductance mH/km

0.86

0.819

0.819

0.819

0.778

0.778

0.778

0.778

0.778

Maximum Mutual Capacitance – pF/m

92

115

101

101

128

128

128

128

128

DC Resistance @ 20°c – OHMS/km

25.3

18.6

18.6

18.6

12.4

12.4

12.4

12.4

12.4

AC Resistance @ 90°c – OHMS/km

32.3

23.7

23.7

23.7

15.9

15.9

15.9

15.9

15.9

Sheath Colour

Grey/Blue

Grey/ Blue

Grey/ Blue

Grey/ Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

KHU00

KHF01

KHR01

KHX01

KHF02

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

KKU00

KKF01

KKR01

KKX01

KKF02

UKOOA Codes (EVA)

UKOOA Codes (CSP)

KHH02 -

(Blue) KKH02

KHJ02 (Blue)

-

KKJ02

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

JHU00

JHF01

JHR01

JHX01

JHF02

JHH02

JHJ02

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

JKU00

JKF01

JKR01

JKX01

JKF02

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

-

(Blue) JKH02

(Blue)

-

JKJ02

(Grey)

(Grey)

Datasheet Ref: OFS-BS-INS-IS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250V Flame Retardant

Offshore Instrumentation Cables to BS6883 Specification

Pairs/Triples/Quads Individually Screened Armoured Cables - Table 3/3 Cable

10x2x1.5

12x2x1.5

20x2x1.5

1x3x1.5

3x3x1.5

5x3x1.5

7x3x1.5

12x3x1.5

1x2x2.5

Stranding mm

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.67

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.7

1.8

2

1.1

1.4

1.5

1.6

1.9

1.1

Diameter over Inner Sheath (min/max) mm

25.6/27.8

27.2/29.4

36.2/39.0

9.4/11.4

16.4/18.4

20.2/22.2

22.3/24.3

30.6/32.6

9.8/11.8

Diameter of Armour/Braid mm

0.45

0.45

0.45

0.3

0.3

0.3

0.3

0.45

0.3

Thickness of Outer Sheath mm

2

2

2.3

1.2

1.5

1.7

1.8

2.1

1.2

Overall Diameter (min/max) mm

31.8/35.0

33.4/36.5

42.9/46.8

13.8/15.8

21.8/23.8

25.9/27.9

28.2/30.2

38.1/40.1

14.1/16.1

Gland Size

C2

C2

D

O

B

C

C

C2

A

Weight kg/km

1323

1907

2250

331

780

1100

1409

2301

320

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

Maximum L/R ratio

38

38

38

38

38

38

38

38

58

Maximum LOOP self inductance mH/km

0.778

0.778

0.778

0.778

0.778

0.778

0.778

0.778

0.731

Maximum Mutual Capacitance – pF/m

128

128

128

111

111

111

111

111

148

DC Resistance @ 20°c – OHMS/km

12.4

12.4

12.4

12.4

12.4

12.4

12.4

12.4

7.71

AC Resistance @ 90°c – OHMS/km

15.9

15.9

15.9

15.9

15.9

15.9

15.9

15.9

9.83

Sheath Colour

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

KHK02

KHL02

KHR02

KHS02

KHT02

KHU02

KHF03

UKOOA Codes (EVA)

-

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

KKK02

KKL02

KKR02

KKS02

KKT02

KKU02

KKF03

UKOOA Codes (CSP)

-

-

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

JHK02

JHL02

JHR02

JHS02

JHT02

JHU02

JHF03

(Blue)

(Blue)

(Blue)

(Blue)

JKK02

JKL02

JKR02

JKS02

(Grey)

(Grey

(Grey)

(Grey)

-

(Blue)

(Blue)

(Blue)

JKT02

JKU02

JKF03

(Grey)

(Grey)

(Grey)

Datasheet Ref: OFS-BS-INS-IS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


Section 1 Offshore Instrumentation Cables to BS6883/BS7917 Specification

FIRE RESISTANT

FPAL Verify

Verified No.10049350

ABS

1


BS6883

Offshore Instrumentation Cables to BS6883 Specification

Pairs/Triples/Quads Armoured Cables – Collectively Screened:

NEK606

150/250 V Fire Resistant

Applicable Standards

IEEE

BS6883 / BS7917 / IEC 60092-359 BS7655 IEC 60331 part 3 (Category A, B &C) IEC-60228 Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS6360

This range of cables is designed for use in fixed wiring in ships and offshore units, e.g. safety and emergency lighting, fire pumps, shut down systems, communication systems, gas detectors, and alarms. These cables are ideal for occupied areas including accommodation facilities, control rooms and computer suites.

IEC

Application

Conductor Identification Single Pair: Black and White Multi-Pair: Black and White Numbered Pairs Triples: Black, White and Red Numbered Triples Quads: Black, White, Red and Blue Numbered Quads New harmonised core colours or project specified colours can be supplied upon special request

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to BS6360 Class 2 (Flexible Class 5 conductors available upon request)

(2) Fire Protection:

Mica Glass Tape

(3) Insulation:

EPR Complying with BS7655 GP4

(4) Collective Screen:

Aluminium Mylar Tape Screen in contact with Tinned Copper drain wire Note: A suitable tape or tapes may be applied over the collectively screened pairs, triples, or quads

(5) Bedding:

EVA - SW4 Thermo set Rubber Compound Complying with BS7655 (UKOOA type GL/GN) OR CSP - SW2 Thermo set Rubber Compound Complying with BS7655 (UKOOA type FL/FN)

(6) Armour:

Galvanised Steel Wire Braid to BS EN 10257-1 Note: A suitable tape or tapes may be applied under and/or over the braid

(7) Outer Sheath:

EVA - SW4 Thermo set Rubber Compound Complying with BS7655 (UKOOA type GL/GN) OR CSP - SW2 Thermo set Rubber Compound Complying with BS7655 (UKOOA type FL/FN)

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

Datasheet Ref: OFS-BS-INS-CS-FS www.interkab.com

FPAL Verify

Verified

No.10049350

ABS


150/250 V Fire Resistant

Offshore Instrumentation Cables to BS6883 Specification

Pairs/Triples/Quads Collectively Screened Armoured Cables - Table 1/2 Cable

2x2x0.75

3x2x0.75

7x2x0.75

12x2x0.75

20x2x0.75

3x3x0.75

7x3x0.75

12x3x0.75

1x2x1.0 1x3x1.0 1x4x1.0 (Ind.Screen) (Ind.Screen) (Ind.Screen)

Stranding mm

24/0.20

24/0.20

24/0.20

24/0.20

24/0.20

24/0.20

24/0.20

24/0.20

32/0.20

32/0.20

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.2

1.2

1.4

1.6

1.8

1.3

1.5

1.8

1

1

1.1

Diameter over Inner Sheath (min/max) mm

11.9/13.9

12.2/14.9

16.1/18.9

20.8/24.4

27.7/31.3

14.8/16.8

19.7/21.7

27.1/29.1

8.8/10.8

9.0/11.0

10.3/12.3

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.45

0.3

0.3

0.45

0.3

0.3

0.3

Diameter over Armour/Braid mm

14.5

14.8

18.7

24

31.5

16.8

21.7

29.4

-

-

-

Thickness of Outer Sheath mm

1.2

1.4

1.5

1.7

2

1.5

1.7

2

1

1

1.2

Overall Diameter (min/max) mm

16.1/18.1

16.4/19.2

20.2/23.8

25.9/29.3

33.2/37.4

18.8/21.2

23.8/26.8

31.6/35.6

13.0/15.0

13.3/15.3

14.3/16.3

Gland Size

A

A

B

C

C2

B

C

C2

O

O

A

Weight kg/km

390

520

780

1150

1900

520

870

1500

180

300

430

32/0.20

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85 100

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

Inductance/ Resistance – mH/W

<25

<25

<25

<25

<25

<25

<25

<25

<25

<25

<25

Capacitance – nF/KM

<110

<90

<90

<90

<90

<90

<90

<90

<140

<110

<110

DC Resistance @ 20°c – OHMS/km

25.3

26.7

26.7

26.7

26.7

26.7

26.7

26.7

18.6

18.6

18.6

DC Resistance @ 85°c – OHMS/km

32.3

33.5

33.5

33.5

33.5

33.5

33.5

33.5

23.7

23.7

23.7

Sheath Colour

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/ Blue

Grey/ Blue

Grey/ Blue

GLH00

GLJ00

GLK00

GLL00

GLS00

GLT00

GLU00

GLF01

GLR01

GLX01

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

GNH00

GNJ00

GNK00

GNL00

GNS00

GNT00

GNU00

GNF01

GNR01

GNX01

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

FLH00

FLJ00

FLK00

FLL00

FLS00

FLT00

FLU00

FLF01

FLR01

FLX01

UKOOA Codes (EVA)

-

UKOOA Codes (CSP)

-

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

FNH00

FNJ00

FNK00

FNL00

FNS00

FNT00

FNU00

FNF01

FNR01

FNX01

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

Pairs/Triples/Quads Collectively Screened Armoured Cables - Table 2/2 Cable

1x2x1.5

2x2x1.5

3x2x1.5

5x2x1.5

7x2x1.5

10x2x1.5

12x2x1.5

24x2x1.5

3x3x1.5

5x3x1.5

7x3x1.5

12x3x1.5

Stranding mm

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.2

1.2

1.3

1.4

1.4

1.7

1.7

2

1.3

1.5

1.5

1.8

Diameter over Inner Sheath (min/max) mm

9.6/10.8

14.3/15.5

15.8/17.4

19.3/21.1

21.0/23.0

26.8/29.0

27.7/29.9

39.0/42.0

19.8/21.8

20.7/22.7

26.7/28.8

36.2/39.0

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.3

0.3

0.45

0.45

0.3

0.3

0.3

0.3

Thickness of Outer Sheath mm

1.3

1.4

1.4

1.6

1.6

1.9

1.9

2.2

1.3

1.5

1.5

1.8

Overall Diameter (min/max) mm

13.6/15.2

18.4/20.0

20.1/26.6

24.0/30.5

25.7/32.6

32.0/39.2

33.7/40.8

45.8/49.7

24.3/31.0

26.5/28.5

31.5/38.7

42.4/50.1

Gland Size

O

A

C

C

C

C2

C2

D

C

C

C2

D

Weight kg/km

320

600

771

1045

1189

1678

1869

3225

979

1287

1594

2647

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

Inductance/ Resistance – mH/W

0.68

0.68

0.68

0.68

0.68

0.68

0.68

0.68

0.68

0.68

0.68

0.68

Capacitance – nF/KM

<110

<110

<110

<110

<110

<110

<110

<110

<110

<110

<110

<110

DC Resistance @ 20°c – OHMS/km

12.4

12.4

12.4

12.4

12.4

12.4

12.4

12.4

12.4

12.4

12.4

12.4

DC Resistance @ 85°c – OHMS/km

15.9

15.9

15.9

15.9

15.9

15.9

15.9

15.9

15.9

15.9

15.9

15.9

Sheath Colour

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

GLT02

GLU02

GLF02 UKOOA Codes (EVA)

UKOOA Codes (CSP)

(Blue) GNF02

GLH02 -

(Blue) GNH02

GLJ02 -

(Blue) GNJ02

GLK02 -

(Blue) GNK02

GLS02 -

(Blue) GNS02

-

(Blue)

(Blue)

GNT02

GNU02

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

FLF02

FLH02

FLJ02

FLK02

FLS02

FLT02

FLU02

(Blue) FNF02 (Grey)

-

(Blue) FNH02 (Grey)

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

-

(Blue) FNJ02 (Grey)

-

(Blue) FNK02 (Grey)

-

(Blue) FNS02 (Grey)

-

(Blue)

(Blue)

FNT02

FNU02

(Grey)

(Grey)

Datasheet Ref: OFS-BS-INS-CS-FS

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883

Offshore Instrumentation Cables to BS6883 Specification

Pairs/Triples/Quads Armoured Cables – Individually Screened:

NEK606

150/250 V Fire Resistant

Applicable Standards

IEEE

BS 6883 / BS7917 / IEC 60092-359 BS7655 IEC 60331 part 3 (Category A, B &C) IEC-60228 Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS6360

Application IEC

This range of cables is designed for use in fixed wiring in ships and offshore units, e.g. safety and emergency lighting, fire pumps, shut down systems, communication systems, gas detectors, and alarms. These cables are ideal for occupied areas including accommodation facilities, control rooms and computer suites.

Conductor Identification Single Pair: Black and White Multi-Pair: Black and White Numbered Pairs Triples: Black, White and Red Numbered Triples Quads: Black, White, Red and Blue Numbered Quads New harmonised core colours or project specified colours can be supplied upon special request

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to BS6360 Class 2 (Flexible Class 5 conductors available upon request)

(2) Fire Protection:

Mica Glass Tape

(3) Insulation:

EPR Complying with BS7655 GP4

(4) Individual Screen:

Aluminium Mylar Tape Screen in contact with Tinned Copper drain wire Note: A suitable tape or tapes may be applied over the collectively screened pairs, triples, or quads

(5) Bedding:

EVA - SW4 Thermo set Rubber Compound Complying with BS7655 (UKOOA type GM/GP) OR CSP - SW2 Thermo set Rubber Compound Complying with BS7655 (UKOOA type FM/FP)

(6) Armour:

Galvanised Steel Wire Braid to BS EN 10257-1 Note: A suitable tape or tapes may be applied under and/or over the braid

(7) Outer Sheath:

EVA - SW4 Thermo set Rubber Compound Complying with BS7655 (UKOOA type GM/GP) OR CSP - SW2 Thermo set Rubber Compound Complying with BS7655 (UKOOA type FM/FP)

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

Datasheet Ref: OFS-BS-INS-IS-FS www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250 V Fire Resistant

Offshore Instrumentation Cables to BS6883 Specification

Pairs/Triples/Quads Individually Screened Armoured Cables - Table 1/2 Cable

2x2x0.75

3x2x0.75

7x2x0.75

12x2x0.75

20x2x0.75

3x3x0.75

7x3x0.75

12x3x0.75

1x4x0.75

1x2x1.0

1x3x1.0

1x4x1.0

Stranding mm

24/0.20

24/0.20

24/0.20

24/0.20

24/0.20

24/0.20

24/0.20

24/0.20

24/0.20

32/0.20

32/0.20

32/0.20

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.2

1.2

1.4

1.6

2.1

1.3

1.5

1.9

1.2

1

1

1

Diameter over Inner Sheath (min/max) mm

9.1/10.9

12.8/15.6

16.9/19.9

22.0/25.8

33.2/35.2

14.8/17.2

19.9/23.3

30.7/32.7

9.3/11.3

8.1/9.9

8.7/10.7

10.5/12.5

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.45

0.3

0.3

0.45

0.3

0.3

0.3

0.3

Diameter over Armour/Braid mm

14.5

15.5

19.7

25.8

35.5

17.2

22.9

33.9

11.6

10.3

11

13.1

Thickness of Outer Sheath mm

1.4

1.4

1.6

1.8

2.7

1.5

1.7

2.2

1.3

1.2

1.2

1.3

Overall Diameter (min/max) mm

12.8/14.8

17.1/20.1

21.3/25.1

27.9/31.5

38.1/42.1

18.8/22.0

25.0/28.2

36.5/40.5

13.1/16.0

11.7/14.3

12.2/15.0

14.9/16.9

Gland Size

O

A

B

C

D

B

C

C2

O

O

O

A

Weight kg/km

305

580

915

1420

2905

700

1180

2550

360

295

330

380

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85 100

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

Inductance/ Resistance – mH/W

<25

<25

<25

<25

<25

<25

<25

<25

<25

<25

<25

<25

Capacitance – nF/KM

<110

<110

<110

<110

<110

<110

<110

<110

<140

<140

<110

<110

DC Resistance @ 20°c – OHMS/KM

25.3

26.7

26.7

26.7

26.7

26.7

26.7

26.7

20

20

26.7

26.7

DC Resistance @ 85°c – OHMS/KM

32.3

33.5

33.5

33.5

33.5

33.5

33.5

33.5

25.1

25.1

33.5

33.5

Sheath Colour

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/ Blue

Grey/ Blue

Grey/ Blue

GMH00

GMJ00

GMK00

GML00

GMS00

GMT00

GMU00

GMX00

GMF01

GMR01

GMX01

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

GPH00

GPJ00

GPK00

GPL00

GPS00

GPT00

GPU00

GPX00

GPF01

GPR01

GPX01

UKOOA Codes (EVA)

UKOOA Codes (CSP)

-

-

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

FMH00

FMJ00

FMK00

FML00

FMS00

FMT00

FMU00

FMX00

FMF01

FMR01

FMX01

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

(Blue)

FPH00

FPJ00

FPK00

FPL00

FPS00

FPT00

FPU00

FPX00

FPF01

FPR01

FPX01

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

Pairs/Triples/Quads Individually Screened Armoured Cables - Table 2/2 Cable

2x2x1.5

3x2x1.5

5x2x1.5

7x2x1.5

10x2x1.5

12x2x1.5

21x2x1.5

24x2x1.5

3x3x1.5

5x3x1.5

7x3x1.5

12x3x1.5

Stranding mm

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.2

1.3

1.4

1.4

1.7

1.7

2

2

1.3

1.5

1.5

1.8

Diameter over Inner Sheath (min/max) mm

14.9/16.5

15.9/17.5

19.5/21.4

21.5/23.6

27.4/29.6

28.6/30.8

42.4/44.4

47.4/49.4

18.1/20.1

22.5/24.5

25.2/27.2

35.3/37.3

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.3

0.45

0.45

0.45

0.3

0.3

0.3

0.45

Thickness of Outer Sheath mm

1.4

1.4

1.6

1.6

1.9

1.9

2.1

2.1

1.5

1.6

1.7

2

Overall Diameter (min/max) mm

19.3/21.5

20.4/22.8

24.2/26.7

26.5/29.1

33.6/36.7

34.8/37.9

50.6/52.6

55.8/57.8

23.5/25.5

28.0/30.0

31.1/33.1

42.9/44.9

Gland Size

B

B

C

C

C2

C2

D

E

B

C

C2

D

Weight kg/km

602

732

1031

1242

1877

2039

2300

2600

780

1100

1409

2301

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

Inductance/ Resistance – mH/W

0.68

0.68

0.68

0.68

0.68

0.68

0.68

0.68

0.68

0.68

0.68

0.68

Capacitance – nF/KM

<110

<110

<110

<110

<110

<110

<110

<110

<110

<110

<110

<110

DC Resistance @ 20°c – OHMS/km

12.4

12.4

12.4

12.4

12.4

12.4

12.4

12.4

12.4

12.4

12.4

12.4

DC Resistance @ 85°c – OHMS/km

15.9

15.9

15.9

15.9

15.9

15.9

15.9

15.9

15.9

15.9

15.9

15.9

Sheath Colour

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

GMT02

GMU02

GMH02 UKOOA Codes (EVA)

UKOOA Codes (CSP)

-

-

(Blue) GPH02

GMJ02 -

(Blue) GPJ02

GMK02 -

(Blue) GPK02

GMS02 -

-

(Blue) GPS02

-

(Blue)

(Blue)

GPT02

GPU02

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

(Grey)

FMH02

FMJ02

FMK02

FMS02

FMT02

FMU02

(Blue) FPH02

-

(Grey)

(Blue) FPJ02 (Grey)

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

-

(Blue) FPK02 (Grey)

-

-

(Blue) FPS02 (Grey)

-

(Blue)

(Blue)

FPT02

FPU02

(Grey)

(Grey)

Datasheet Ref: OFS-BS-INS-IS-FS www.interkab.com FPAL Verify

Verified

No.10049350

ABS


Section 2 Offshore Power & Control Cables to BS6883 Specification

FLAME RETARDANT

FPAL Verify

Verified No.10049350

ABS

2


BS6883 600/1000V Flame Retardant BS6883 - Power Cables Single core armoured:

NEK606

Offshore Power Cables to BS6883 Specification

Applicable Standards

IEEE

BS6883 / IEC 60092-3 BS7655 BS EN 12166 IEC 60332 part 3 (Category A) IEC-60228 Stranded class 2 or tinned annealed copper conductors to BS6360

Application IEC

This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.

Conductor Identification 1 Core – Black New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to BS6360

(2) Insulation:

EPR Complying with BS7655 GP5

(3) Bedding:

EVA – SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance LSZH (UKOOA type WA) OR CSP – SW2 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance (UKOOA type LA)

(4) Armour:

Tinned Phosphor Bronze Wire Braid to BS2873-PB102 (now BS EN 12166)

(5) Outer Sheath:

EVA – SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance and LSZH (UKOOA type WA) OR CSP – SW2 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance (UKOOA type LA)

Datasheet Ref: OFS-BS-PC-SC-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000V Flame Retardant

Offshore Power Cables to BS6883 Specification

Singlecore Armoured Power/Control Cables - Table 1/2 Cable

1x1.0

1x1.5

1x2.5

1x4

1x6

1x10

1x16

1x25

1x35

1x50

Stranding mm

7/0.44

7/0.53

7/0.67

7/0.85

7/1.0

7/1.35

7/1.70

7/2.14

19/1.53

19/1.78 1.4

Insulation Thickness mm

0.8

0.8

0.8

1

1

1

1

1.2

1.2

Thickness of Inner Sheath mm

-

-

-

-

-

-

1.1

1.1

1.1

1.1

Diameter over Inner Sheath (min/max) mm

4.6/6.6

4.9/6.9

5.3/7.3

6.3/8.3

6.8/8.8

7.8/9.8

9.0/11.0

11.4/13.4

12.3/14.3

14.1/16.1 0.3

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Thickness of Outer Sheath mm

-

-

-

-

-

-

1.2

1.2

1.3

1.4

Overall Diameter (min/max) mm

8.5/10.5

8.8/10.8

9.2/11.2

10.3/12.3

10.8/12.8

12.0/14.0

13.2/15.2

15.8/17.8

16.9/18.9

18.7/20.7

Gland Size

Os

Os

Os

O

O

O

O

A

A

B

Weight kg/km

150

170

190

260

340

390

480

565

740

940

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

Inductance– mH/km

-

-

-

-

0.464

0.433

0.405

0.379

0.368

0.357

Capacitance – μF/km

-

-

-

-

0.522

0.379

0.447

0.464

0.514

0.522

DC Resistance @ 20°c – Ώ/km

-

-

-

-

3.11

1.84

1.16

0.734

0.529

0.391

DC Resistance @ 90°c – Ώ/km

-

-

-

-

3.965

2.346

1.479

0.936

0.674

0.499

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

UKOOA Codes (EVA)

WA101

WA102

WA103

WA104

WA106

WA110

WA116

WA125

WA130

WA150

UKOOA Codes (CSP)

LA101

LA102

LA103

LA104

LA106

LA110

LA116

LA125

LA130

LA150

Singlecore Armoured Power/Control Cables - Table 2/2 Cable

1x70

1x95

1x120

1x150

1x185

1x240

1x300

1x400

1x500

1x630

Stranding mm

19/2.14

37/1.78

37/2.03

37/2.25

37/2.52

61/2.25

61/2.52

91/2.36

91/2.65

127/2.52

Insulation Thickness mm

1.4

1.6

1.6

1.8

2

2.2

2.4

2.6

2.8

2.8

Thickness of Inner Sheath mm

1

1.2

1.4

1.6

1.8

1.3

1.5

1.7

1.2

1

Diameter over Inner Sheath (min/max) mm

16.0/18.0

18.4/20.4

20.4/22.4

22.6/24.6

25.0/27.0

28.3/30.3

31.5/33.5

35.4/37.4

39.4/41.4

43.3/45.3

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.45

0.45

0.45

0.45

0.45

0.45

Diameter over Armour/Braid mm

-

14

17.7

23.1

31.4

15.5

20.4

28.9

11

9.8

Thickness of Outer Sheath mm

1.4

1.4

1.6

1.8

2.1

1.5

1.7

2

1.3

1.2

Overall Diameter (min/max) mm

20.9/22.9

23.5/25.5

25.6/27.6

28.0/30.0

31.6/33.6

35.0/37.0

38.2/40.2

42.7/44.7

47.1/49.1

51.3/53.3

Gland Size

B

B

C

C

C2

C2

C2

D

D

E

Weight kg/km

1270

1500

1750

2200

2700

3400

4200

5700

7200

8840

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

Inductance- mH/km

0.341

0.33

0.321

0.318

0.319

0.31

0.306

0.301

0.296

0.289

Capacitance – μF/km

0.609

0.628

0.694

0.694

0.705

0.727

0.75

0.793

0.821

0.904

DC Resistance @ 20°c – Ώ/km

0.27

0.195

0.154

0.126

0.1

0.0762

0.0607

0.0475

0.0369

0.0286

DC Resistance @ 90°c – Ώ/km

0.344

0.271

0.214

0.175

0.14

0.108

0.087

0.069

0.058

0.045

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

UKOOA Codes (EVA)

WA170

WA195

WA10A

WA10B

WA10C

WA10D

WA10E

WA10F

WA10G

WA10H

UKOOA Codes (CSP)

LA170

LA195

LA10A

LA10B

LA10C

LA10D

LA10E

LA10F

LA10G

LA10H

Datasheet Ref: OFS-BS-PC-SC-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 600/1000V Flame Retardant BS6883 - Power Cables Multi core armoured:

NEK606

Offshore Power Cables to BS6883 Specification

Applicable Standards

IEEE

BS6883 / IEC 60092-3 BS7655 BS EN 10257-1 IEC 60332 part 3 (Category A) IEC-60228 Stranded class 2 or tinned annealed copper conductors to BS6360

Application IEC

This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.

Conductor Identification 1 2 3 4 5

Core Core Core Core Core

– White – White and Numbered (Red, Black on Request) – White and Numbered (Red, Yellow, Blue on Request) – White and numbered (Red, Yellow, Blue, Black on Request) & Above – White and Numbered

New harmonised core colours or project specified colours can be supplied upon special request

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to BS6360

(2) Insulation:

EPR Complying with BS7655 GP5

(3) Bedding:

EVA – SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance and LSZH (UKOOA type WB) CSP – SW2 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance (UKOOA type LB)

(4) Armour:

Galvanised Steel Wire Braid to BS EN 10257-1

(5) Outer Sheath:

EVA – SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance and LSZH (UKOOA type WB) CSP – SW2 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance (UKOOA type LB)

Datasheet Ref: OFS-BS-PC-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000V Flame Retardant

Offshore Power Cables to BS6883 Specification

Multicore Armoured Power/Control Cables - Table 1/5 Cable

2 x1.5

2 x 2.5

2x4

2x6

2 x10

2 x 16

2 x 25

2 x 35

2 x 50

2 x 70

2 x 95

2 x 120

2x150

2 x 185

Stranding mm

7/0.53

7/0.67

7/0.85

7/1.00

7/1.35

7/1.70

7/2.14

19/1.53

19/1.78

19/2.14

37/1.78

37/2.03

37/2.25

37/2.52

Insulation Thickness mm

0.8

0.8

1

1

1

1

1.2

1.2

1.4

1.4

1.6

1.6

1.8

2

Thickness of Inner Sheath mm

1.1

1.1

1.2

1.2

-

1.4

-

1.6

-

-

-

-

-

-

Diameter over Inner Sheath (min/max) mm

8.7/10.7

9.6/11.6

11.7/13.7

12.8/14.8

14.9/16.9

17.2/19.2

21.7/23.7

23.7/25.7

27.2/29.2

31.3/33.3

36.0/38.0

39.8/41.8

44.0/46.0

49.0/51.0 0.45

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.45

0.45

0.45

0.45

0.45

Thickness of Outer Sheath mm

1.2

1.2

1.3

1.4

-

1.5

-

1.8

-

-

-

-

-

-

Overall Diameter (min/max) mm

12.9/14.9

13.7/15.7

16.1/18.1

17.3/19.3

19.7/21.7

22.2/24.2

26.9/28.9

29.1/31.1

33.9/35.9

38.2/40.2

43.5/45.5

47.6/49.6

52.1/54.1

57.2/59.2

Gland Size

O

O

A

A

B

B

C

C

C2

C2

D

D

E

E

Weight kg/km

270

310

430

520

680

850

1500

1810

2510

3230

4220

5125

6210

7500

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/– mH/km

0.353

0.33

0.329

0.311

0.292

0.277

0.267

0.259

0.258

0.25

0.245

0.241

0.24

0.241 0.374

Capacitance – μF/KM

0.133

0.153

0.158

0.181

0.213

0.248

0.26

0.282

0.288

0.325

0.333

0.366

0.369

DC Resistance max @ 20°c - Ώ/km

12.2

7.56

4.7

3.11

1.84

1.16

0.734

0.529

0.391

0.27

0.195

0.154

0.126

0.1

DC Resistance max @ 90°c - Ώ/km

15.555

9.639

5.993

3.965

2.346

1.479

0.936

0.674

0.499

0.344

0.271

0.214

0.175

0.14

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

UKOOA Code (EVA)

WB202

WB203

WB204

WB206

WB210

WB216

WB225

WB235

WB250

WB270

WB295

WB20A

WB20B

WB20C

UKOOA Code (CSP)

LB202

LB203

LB204

LB206

LB210

LB216

LB225

LB235

LB250

LB270

LB295

LB20A

LB20B

LB20C

Multicore Armoured Power/Control Cables - Table 2/5 Cable

2 x 240

2 x 300

3 x 1.5

3 x 2.5

3x4

3x6

3 x 10

3 x 16

3 x 25

3 x 35

3 x 50

3 x 70

3 x 95

3x120

Stranding mm

61/2.25

61/2.52

7/0.53

7/0.67

7/0.85

7/1.00

7/1.35

7/1.70

7/2.14

19/1.53

19/1.78

19/2.14

37/1.78

37/2.03

Insulation Thickness mm

2.2

2.4

0.8

0.8

1

1

1

1

1.2

1.2

1.4

1.4

1.6

1.6

Thickness of Inner Sheath mm

-

-

1.1

1.1

1.2

1.2

1.3

1.4

1.6

1.7

1.8

2

2.2

-

Diameter over Inner Sheath (min/max) mm

55.7/57.7

62.0/64.0

9.3/11.3

10.2/12.2

12.4/14.4

13.7/15.7

15.9/17.9

18.4/20.4

23.4/25.4

25.5/27.5

29.4/31.4

33.7/35.7

38.8/40.8

42.9/44.9 0.45

Diameter of Armour/Braid mm

0.45

0.45

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.45

0.45

0.45

0.45

Thickness of Outer Sheath mm

-

-

1.2

1.3

1.3

1.4

1.5

1.6

1.8

1.9

2

2.2

2.4

-

Overall Diameter (min/max) mm

64.9/66.9

71.5/73.5

13.4/15.4

14.6/16.6

16.8/18.8

18.3/20.3

20.9/22.9

23.5/25.5

28.8/30.8

32.1/34.1

36.0/38.0

40.9/42.9

46.4/48.4

51.0/53.0

Gland Size

F

F

O

A

A

A

B

B

C

C2

C2

D

D

E

Weight kg/km

9440

11500

290

390

520

620

850

1150

1600

2200

3000

3980

5295

6490

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/– mH/km

0.238

0.238

0.353

0.33

0.329

0.311

0.292

0.277

0.267

0.259

0.258

0.25

0.245

0.241

Capacitance – μF/KM

0.381

0.392

0.133

0.153

0.158

0.181

0.213

0.248

0.26

0.282

0.288

0.325

0.333

0.366

DC Resistance max @ 20°c - Ώ/km

0.0762

0.0607

12.2

7.56

4.7

3.11

1.84

1.16

0.734

0.529

0.391

0.27

0.195

0.154

DC Resistance max @ 90°c - Ώ/km

0.108

0.087

15.555

9.639

5.993

3.965

2.346

1.479

0.936

0.674

0.499

0.344

0.271

0.214

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

UKOOA Code (EVA))

WB20D

WB20E

WB302

WB303

WB304

WB306

WB310

WB316

WB325

WB335

WB350

WB370

WB395

WB30A

UKOOA Code (CSP)

LB20D

LB20E

LB302

LB303

LB304

LB306

LB310

LB316

LB325

LB335

LB350

LB370

LB395

LB30A

Datasheet Ref: OFS-BS-PC-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000V Flame Retardant

Offshore Instrumentation to BS6883 Specification Offshore Power CablesCables to BS6883 Specification

Multicore Armoured Power/Control Cables - Table 3/5 Cable

3 x 150

3 x 185

3 x 240

3 x 300

4 x 1.5

4 x 2.5

4x4

4x6

4 x 10

4 x 16

4 x 25

4 x 35

4 x 50

4 x 70

Stranding mm

37/2.25

37/2.52

61/2.25

61/2.52

7/0.53

7/0.67

7/0.85

7/1.00

7/1.35

7/1.70

7/2.14

19/1.53

19/1.78

19/2.14

Insulation Thickness mm

1.8

2

2.2

2.4

0.8

0.8

1

1

1

1

1.2

1.2

1.4

1.4

Thickness of Inner Sheath mm

-

-

-

-

1.1

1.1

1.2

1.3

1.4

1.5

1.7

1.8

1.9

2.1

Diameter over Inner Sheath (min/max) mm

47.5/49.5

53.0/55.0

60.0/62.0

66.8/68.8

10.2/12.2

11.2/13.2

13.7/15.7

15.3/17.3

17.7/19.7

20.7/22.7

26.0/28.0

28.4/30.4

32.7/34.7

37.5/39.5

Diameter of Armour/Braid mm

0.45

0.45

0.45

0.45

0.3

0.3

0.3

0.3

0.3

0.3

0.45

0.45

0.45

0.45

Thickness of Outer Sheath mm

-

-

-

-

1.3

1.3

1.4

1.5

1.6

1.7

1.9

2

2.2

2.4

Overall Diameter (min/max) mm

56.0/58.0

61.9/63.9

64.2/66.2

76.7/78.7

14.6/16.6

15.6/17.6

18.3/20.3

20.3/22.3

22.9/24.9

25.9/27.9

32.6/34.6

35.1/37.1

39.9/41.9

45.1/47.1

Gland Size

E

E

F

G

A

A

A

B

B

C

C2

C2

D

D

Weight kg/km

7690

9550

12400

14900

360

470

620

760

1100

1500

2100

2700

3400

4600

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/– mH/km

0.24

0.241

0.238

0.238

0.353

0.33

0.329

0.311

0.292

0.277

0.267

0.0259

0.258

0.25 0.325

Capacitance – μF/KM

0.369

0.374

0.381

0.392

0.133

0.153

0.158

0.181

0.213

0.248

0.26

0.282

0.288

DC Resistance max @ 20°c - Ώ/km

0.126

0.1

0.076

0.0607

12.2

7.56

4.7

3.11

1.84

1.16

0.734

0.529

0.391

0.27

DC Resistance max @ 90°c - Ώ/km

0.175

0.14

0.108

0.087

15.555

9.639

5.993

3.965

2.346

1.479

0.936

0.674

0.499

0.344

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

UKOOA Code (EVA)

WB30B

WB30C

WB30D

WB30E

WB402

WB403

WB404

WB406

WB410

WB416

WB425

WB435

WB450

WB470

UKOOA Code (CSP)

LB30B

LB30C

LB30D

LB30E

LB402

LB403

LB404

LB406

LB410

LB416

LB425

LB435

LB450

LB470

Multicore Armoured Power/Control Cables - Table 4/5 Cable

4 x 95

4 x 120

4 x 150

4 x 185

4 x 240

4 x 300

5 x 1.5

5 x 2.5

5x4

7 x 1.5

7 x 2.5

7x4

10 x 1.5

10 x 2.5

Stranding mm

37/1.78

37/2.03

37/2.25

37/2.52

61/2.25

61/2.52

7/0.53

7/0.67

7/0.85

7/0.53

7/0.67

7/0.85

7/0.53

7/0.67

Insulation Thickness mm

1.6

1.6

1.8

2

2.2

2.4

0.8

0.8

1

0.8

0.8

1

0.8

0.8

Thickness of Inner Sheath mm

2.3

-

-

-

-

-

1.1

-

-

1.2

1.2

-

-

-

Diameter over Inner Sheath (min/max) mm

43.3/45.3

47.9/49.9

53.1/55.1

59.1/61.1

67.1/69.1

74.7/76.7

11.1/13.1

12.5/14.5

15.3/17.3

12.4/14.4

13.6/15.6

16.7/18.7

16.0/18.0

17.8/19.8 0.3

Diameter of Armour/Braid mm

0.45

0.45

0.45

0.45

0.45

0.45

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Thickness of Outer Sheath mm

2.6

-

-

-

-

-

1.3

-

-

1.3

1.4

-

-

-

Overall Diameter (min/max) mm

51.3/53.3

56.4/58.4

62.1/64.1

68.4/70.4

77.1/79.1

85.3/87.3

15.5/17.5

16.8/18.8

20.2/22.2

16.8/18.8

18.2.6/20.2

21.7/23.7

21.0/23.0

22.8./24.8

Gland Size

E

E

E

E

G

G

A

A

B

A

A

B

B

B

Weight kg/km

5700

6900

8200

10260

13200

16300

420

550

720

520

600

800

720

810

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

85 100

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/– mH/km

0.245

0.241

0.24

0.241

0.238

0.238

0.353

0.33

0.329

0.353

0.33

-

-

-

Capacitance – μF/KM

0.333

0.366

0.369

0.374

0.381

0.392

0.133

0.153

0.158

0.133

0.153

-

-

-

DC Resistance max @ 20°c - Ώ/km

0.195

0.154

0.126

0.1

0.0762

0.0607

12.2

7.56

4.7

12.2

7.56

-

-

-

DC Resistance max @ 90°c - Ώ/km

0.271

0.214

0.175

0.14

0.108

0.087

15.555

9.639

5.993

15.555

9.639

-

-

Black

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

UKOOA Code (EVA)

WB495

WB40A

WB40B

WB40C

WB40D

WB40E

WB502

WB503

WB504

WB702

WB703

WB704

-

-

UKOOA Code (CSP)

LB495

LB40A

LB40B

LB40C

LB40D

LB40E

LB502

LB503

LB504

LB702

LB703

LB704

-

-

Datasheet Ref: OFS-BS-PC-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000V Flame Retardant

Offshore Instrumentation to BS6883 Specification Offshore Power CablesCables to BS6883 Specification

Multicore Armoured Power/Control Cables - Table 5/5 Cable

12 x 1.5

12x2.5

19x1.5

19x2.5

27 x 1.5

27 x 2.5

30 x 1.5

30 x 2.5

37 x 1.5

37 x 2.5

30 x 1.5

30 x 2.5

Stranding mm

7/0.53

7/0.67

7/0.53

7/0.67

7/0.53

7/0.67

7/0.53

7/0.67

7/0.53

7/0.67

7/0.53

7/0.67

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.3

1.4

1.4

1.5

-

1.7

-

-

-

1.8

-

-

Diameter over Inner Sheath (min/max) mm

16.5/18.5

18.5/20.5

19.8/21.8

22.1/24.1

24.1/26.1

26.8/28.8

25.0/27.0

27.9/29.9

27.1/29.1

30.4/32.4

31.4/33.4

35.2/37.2 0.45

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.45

0.45

0.45

0.45

Thickness of Outer Sheath mm

1.5

1.6

1.6

1.7

-

1.9

-

-

-

2

-

-

Overall Diameter (min/max) mm

21.5/23.5

23.6/25.6

24.8/26.8

27.3/29.3

29.7/31.7

33.4/35.4

30.6/32.6

34.6/36.6

33.7/35.7

37.0/39.0

38.2/40.2

42.4/44.4

Gland Size

B

B

C

C

C

C2

C

C2

C2

C2

C2

D

Weight kg/km

850

950

1100

1400

1500

1800

1950

2150

2700

2950

3500

3800

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/– mH/km

0.353

0.33

0.353

0.33

0.353

0.33

-

-

0.353

0.33

-

-

Capacitance – μF/KM

0.133

0.153

0.133

0.153

0.133

0.153

-

-

0.133

0.153

-

-

DC Resistance max @ 20°c - Ώ/km

12.2

7.56

12.2

7.56

12.2

7.56

-

-

12.2

7.56

-

-

DC Resistance max @ 90°c - Ώ/km

15.555

9.639

15.555

9.639

15.555

9.639

-

-

15.56

9.639

-

-

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

UKOOA Code (EVA)

WBA02

WBA03

WBB02

WBB03

WBC02

WBC03

-

-

WBD02

WBD03

-

-

UKOOA Code (CSP)

LBA02

LBA03

LBB02

LBB03

LBC02

LBC03

-

-

LBD02

LBD03

-

-

Datasheet Ref: OFS-BS-PC-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


Section 2 Offshore Power & Control Cables to BS6883/BS7917 Specification

FIRE RESISTANT

FPAL Verify

Verified No.10049350

ABS

2


BS6883

Offshore Power Cables to BS6883 Specification

BS6883 - Power Cables Single core armoured:

NEK606

600/1000 V Fire Resistant

Applicable Standards

IEEE

BS6883 / BS7917/ IEC 60092-3 BS7655 BS EN 12166 IEC 60331 part 3 (Category A) IEC-60228 Stranded class 2 or tinned annealed copper conductors to BS6360

IEC

Application This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.

Conductor Identification 1 Core – Black New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to BS6360

(2) Fire Protection

Mica Glass Tape

(3) Insulation:

EPR Complying with BS7655 GP5

(4) Bedding:

EVA – SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance and LSZH (UKOOA type YC) OR CSP – SW2 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance (UKOOA type XC)

(5) Armour:

Tinned Phosphor Bronze Wire Braid to BS2873-PB102 (now BS EN 12166)

(6) Outer Sheath:

EVA – SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance and LSZH (UKOOA type YC) OR CSP – SW2 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance (UKOOA type XC)

Datasheet Ref: OFS-BS-PC-SC-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000 V Fire Resistant

Offshore Power Cables to BS6883 Specification

Singlecore Armoured Power/Control Cables - Table 1/2 Cable

1x1.0

1x1.5

1x2.5

1x4

1x6

1x10

1x16

1x25

1x35

1x50

Stranding mm

7/044

7/0.53

7/0.67

7/0.85

7/1.0

7/1.35

7/1.70

7/2.14

19/1.53

19/1.78

Insulation Thickness mm

0.8

0.8

0.8

1

1

1

1

1.2

1.2

1.4

Thickness of Inner Sheath mm

-

-

-

-

-

-

1.1

1.1

1.1

1.1

Diameter over Inner Sheath (min/max) mm

5.1/7.1

5.4/7.4

5.8/7.8

6.8/8.8

7.3/9.3

8.3/10.3

9.5/11.5

11.9/13.9

12.8/14.8

14.6/16.6 0.3

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Thickness of Outer Sheath mm

-

-

-

-

-

-

1.2

1.2

1.3

1.4

Overall Diameter (min/max) mm

9.0/11.0

9.3/11.3

9.7/11.7

10.8/12.8

11.3/13.3

12.5/14.5

13.7/15.7

16.3/18.3

17.4/19.4

19.2/21.2

Gland Size

O

O

O

O

O

O

O

A

A

B

Weight kg/km

158

179

200

273

357

410

504

593

777

987

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

Inductance– mH/km

-

-

-

-

0.464

0.433

0.405

0.379

0.368

0.357

Capacitance – μF/km

-

-

-

-

0.522

0.379

0.447

0.464

0.514

0.522

DC Resistance @ 20°c – Ώ/km

-

-

-

-

3.11

1.84

1.16

0.734

0.529

0.391

DC Resistance @ 90°c – Ώ/km

-

-

-

-

3.965

2.346

1.479

0.936

0.674

0.499

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

UKOOA Codes (EVA)

YC101

YC102

YC103

YC104

YC106

YC110

YC116

YC125

YC130

YC150

UKOOA Codes (CSP)

XC101

XC102

XC103

XC104

XC106

XC110

XC116

XC125

XC130

XC150

Singlecore Armoured Power/Control Cables - Table 2/2 Cable

1x70

1x95

1x120

1x150

1x185

1x240

1x300

1x400

1x500

1x630

Stranding mm

19/2.14

37/1.78

37/2.03

37/2.25

37/2.52

61/2.25

61/2.52

91/2.36

91/2.65

127/2.52

Insulation Thickness mm

1.4

1.6

1.6

1.8

2

2.2

2.4

2.6

2.8

2.8

Thickness of Inner Sheath mm

1.1

1.1

1.2

1.2

1.2

1.2

1.2

-

-

-

Diameter over Inner Sheath (min/max) mm

16.5/18.5

18.9/20.9

20.9/22.9

23.1/25.1

25.5/27.5

28.8/30.8

32.0/34.0

35.9/37.9

39.9/41.9

43.8/45.8 0.45

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.45

0.45

0.45

0.45

0.45

Thickness of Outer Sheath mm

1.4

1.5

1.6

1.6

1.7

1.8

1.9

-

-

-

Overall Diameter (min/max) mm

21.4/23.4

24.0/26.0

26.1/28.1

28.5/30.5

32.1/34.1

35.5/37.5

39.0/41.0

43.2/45.2

47.6/49.6

51.8/53.8

Gland Size

B

B

C

C

C2

C2

C2

D

D

E

Weight kg/km

1333

1575

1838

2310

2835

3570

4410

5985

7560

9282

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

Inductance– mH/km

0.341

0.33

0.321

0.318

0.319

0.31

0.306

0.301

0.296

0.289

Capacitance – μF/km

0.609

0.628

0.694

0.694

0.705

0.727

0.75

0.793

0.821

0.904

DC Resistance @ 20°c – Ώ/km

0.27

0.195

0.154

0.126

0.1

0.0762

0.0607

0.0475

0.0369

0.0286

DC Resistance @ 90°c – Ώ/km

0.344

0.271

0.214

0.175

0.14

0.108

0.087

0.069

0.058

0.045

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

UKOOA Codes (EVA)

YC170

YC195

YC10A

YC10B

YC10C

YC10D

YC10E

YC10F

YC10G

YC10H

UKOOA Codes (CSP)

XC170

XC195

XC10A

XC10B

XC10C

XC10D

XC10E

XC10F

XC10G

XC10H

Datasheet Ref: OFS-BS-PC-SC-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 600/1000 V Fire Resistant

BS6883 - Power Cables Multi core armoured:

NEK606

Offshore Power Cables to BS6883 Specification Applicable Standards

IEEE

BS6883 / BS7917/ IEC 60092-3 BS7655 BS EN 10257-1 IEC 60331 part 3 (Category A) IEC-60228 Stranded class 2 or tinned annealed copper conductors to BS6360

Application IEC

This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.

Conductor Identification 1 2 3 4 5 Note: picture is for illustration purposes only

Core Core Core Core Core

– White – White and Numbered (Red, Black on Request) – White and Numbered (Red, Yellow, Blue on Request) – White and numbered (Red, Yellow, Blue, Black on Request) & Above – White and Numbered

New harmonised core colours or project specified colours can be supplied upon special request

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to BS6360

(2) Fire Protection

Mica Glass Tape

(3) Insulation:

EPR Complying with BS7655 GP5

(4) Bedding:

EVA – SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance and LSZH (UKOOA type YD) OR CSP – SW2 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance (UKOOA type XD)

(5) Armour:

Galvanised Steel Wire Braid to BS EN 10257-1

(6) Outer Sheath:

EVA – SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance and LSZH (UKOOA type YD) OR CSP – SW2 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance (UKOOA type XD)

Datasheet Ref: OFS-BS-PC-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000 V Fire Resistant

Offshore Power Cables to BS6883 Specification

Multicore Armoured Power/Control Cables - Table 1/5 Cable

2 x1.5

2 x 2.5

2x4

2x6

2 x10

2 x 16

2 x 25

2 x 35

2 x 50

2 x 70

2 x 95

2 x 120

2x150

2 x 185

Stranding mm

7/0.53

7/0.67

7/0.85

7/1.00

7/1.35

7/1.70

7/2.14

19/1.53

19/1.78

19/2.14

37/1.78

37/2.03

37/2.25

37/2.52

Insulation Thickness mm

0.8

0.8

1

1

1

1

1.2

1.2

1.4

1.4

1.6

1.6

1.8

2

Thickness of Inner Sheath mm

1.1

1.1

1.2

1.2

1.3

1.4

-

1.6

-

-

-

-

-

-

Diameter over Inner Sheath (min/max) mm

9.7/11.7

10.6/12.6

12.7/14.7

13.8/15.8

15.9/17.9

18.2/20.2

22.7/24.7

24.7/26.7

28.2/30.2

32.3/34.3

37.0/39.0

40.8/42.8

45.0/47.0

50.0/52.0 0.45

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.45

0.45

0.45

Thickness of Outer Sheath mm

1.2

1.2

1.3

1.4

1.4

1.5

-

1.8

-

-

-

-

-

-

Overall Diameter (min/max) mm

13.9/15.9

14.7/16.7

17.1/19.1

18.3/20.3

20.7/22.7

23.2/25.2

27.9/29.9

30.1/32.1

34.9/36.9

39.2/41.2

44.5/46.5

48.6/50.6

53.1/55.1

58.2/60.2

Gland Size

O

A

A

A

B

B

C

C

C2

D

D

D

E

E

Weight kg/km

270

310

430

520

680

850

1500

1810

2510

3230

4220

5125

6210

7500

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/– mH/km

0.391

0.371

0.353

0.332

0.316

0.304

0.283

0.278

0.272

0.264

0.259

0.254

0.251

0.25 0.323

Capacitance – μF/KM

0.112

0.126

0.14

0.157

0.18

0.201

0.223

0.232

0.248

0.274

0.286

0.303

0.315

DC Resistance max @ 20°c - Ώ/km

12.2

7.56

4.7

3.11

1.84

1.16

0.734

0.529

0.391

0.27

0.195

0.154

0.126

0.1

DC Resistance max @ 90°c - Ώ/km

15.555

9.639

5.993

3.965

2.346

1.479

0.936

0.674

0.499

0.344

0.271

0.214

0.175

0.14

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

UKOOA Code (EVA)

YD202

YD203

YD204

YD206

YD210

YD216

YD225

YD235

YD250

YD270

YD295

YD20A

YD20B

YD20C

UKOOA Code (CSP)

XD202

XD203

XD204

XD206

XD210

XD216

XD225

XD235

XD250

XD270

XD295

XD20A

XD20B

XD20C

Multicore Armoured Power/Control Cables - Table 2/5 Cable

2 x 240

2 x 300

3 x 1.5

3 x 2.5

3x4

3x6

3 x 10

3 x 16

3 x 25

3 x 35

3 x 50

3 x 70

3 x 95

3x120

Stranding mm

61/2.25

61/2.52

7/0.53

7/0.67

7/0.85

7/1.0

7/1.35

7/1.70

7/2.14

19/1.53

19/1.78

19/2.14

37/1.78

37/2.03

Insulation Thickness mm

2.2

2.4

0.8

0.8

1

1

1

1

1.2

1.2

1.4

1.4

1.6

1.6

Thickness of Inner Sheath mm

-

-

1.1

1.1

1.2

1.2

1.3

1.4

1.6

1.7

1.8

2

2.2

-

Diameter over Inner Sheath (min/max) mm

56.7/58.7

63.0/65.0

10.8/12.8

11.7/13.7

13.9/15.9

15.2/17.2

17.4/19.4

19.9/21.9

24.9/26.9

27.0/29.0

30.9/32.9

35.2/37.2

40.3/42.3

44.4/46.4 0.45

Diameter of Armour/Braid mm

0.45

0.45

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.45

0.45

0.45

0.45

Thickness of Outer Sheath mm

-

-

1.2

1.3

1.3

1.4

1.5

1.6

1.8

1.9

2

2.2

2.4

-

Overall Diameter (min/max) mm

65.9/67.9

72.5/74.5

14.9/16.9

16.1/18.1

18.3/20.3

19.8/21.8

22.4/24.4

25.0/27.0

30.3/32.3

33.6/35.6

37.5/39.5

42.4/44.4

47.9/49.9

52.5/54.5

Gland Size

F

F

A

A

A

B

B

C

C

C2

C2

D

D

E

Weight kg/km

9440

11500

290

390

520

620

850

1150

1600

2200

3000

3980

5295

6490

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/– mH/km

0.244

0.243

0.391

0.371

0.353

0.332

0.316

0.304

0.283

0.278

0.272

0.264

0.259

0.254

Capacitance – μF/KM

0.348

0.357

0.112

0.126

0.14

0.157

0.18

0.201

0.223

0.232

0.248

0.274

0.286

0.303

DC Resistance max @ 20°c - Ώ/km

0.0762

0.0607

12.2

7.56

4.7

3.11

1.84

1.16

0.734

0.529

0.391

0.27

0.195

0.154

DC Resistance max @ 90°c - Ώ/km

0.108

0.087

15.555

9.639

5.993

3.965

2.346

1.479

0.936

0.674

0.499

0.344

0.271

0.214

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

UKOOA Code (EVA)

YD20D

YD20E

YD302

YD303

YD304

YD306

YD310

YD316

YD325

YD335

YD350

YD370

YD395

YD30A

UKOOA Code (CSP)

XD20D

XD20E

XD302

XD303

XD304

XD306

XD310

XD316

XD325

XD335

XD350

XD370

XD395

XD30A

Datasheet Ref: OFS-BS-PC-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000 V Fire Resistant

Offshore Power Cables to BS6883 Specification

Multicore Armoured Power/Control Cables - Table 3/5 Cable

3 x 150

3 x 185

3 x 240

3 x 300

4 x 1.5

4 x 2.5

4x4

4x6

4 x 10

4 x 16

4 x 25

4 x 35

4 x 50

4 x 70

Stranding mm

37/2.25

37/2.52

61/2.25

61/2.52

7/0.53

7/0.67

7/0.85

7/1.00

7/1.35

7/1.70

7/2.14

19/1.53

19/1.78

19/2.14

Insulation Thickness mm

1.8

2

2.2

2.4

0.8

0.8

1

1

1

1

1.2

1.2

1.4

1.4

Thickness of Inner Sheath mm

-

-

-

-

1.1

1.1

1.2

1.3

-

-

-

1.8

-

2.1

Diameter over Inner Sheath (min/max) mm

49.0/51.0

54.5/56.5

61.5/63.5

68.3/70.3

12.1/14.1

13.1/15.1

15.6/17.6

17.2/19.2

19.7/21.7

22.5/24.5

28.4/30.4

31.1/33.1

36.2/38.2

41.4/43.4 0.45

Diameter of Armour/Braid mm

0.45

0.45

0.45

0.45

0.3

0.3

0.3

0.3

0.3

0.3

0.45

0.45

0.45

Thickness of Outer Sheath mm

-

-

-

-

1.3

1.3

1.4

1.5

-

-

-

2

-

2.4

Overall Diameter (min/max) mm

57.5/59.5

63.4/65.4

65.7/67.7

78.2/80.2

15.3/17.3

16.3/18.3

19.0/21.0

20.8/22.8

23.5/25.5

26.5/28.5

33.1/35.1

36.0/38.0

41.5/43.5

47.1/49.1

Gland Size

E

F

F

G

A

A

B

B

B

C

C2

C2

D

D

Weight kg/km

7690

9550

12400

14900

360

470

620

760

1100

1500

2100

2700

3400

4600

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/– mH/km

0.251

0.25

0.244

0.243

0.391

0.371

0.353

0.332

0.316

0.304

0.283

0.278

0.272

0.264 0.274

Capacitance – μF/KM

0.315

0.323

0.348

0.357

0.112

0.126

0.14

0.157

0.18

0.201

0.223

0.232

0.248

DC Resistance max @ 20°c - Ώ/km

0.126

0.1

0.0762

0.0607

12.2

7.56

4.7

3.11

1.84

1.16

0.734

0.529

0.391

0.27

DC Resistance max @ 90°c - Ώ/km

0.175

0.14

0.108

0.087

15.555

9.639

5.993

3.965

2.346

1.479

0.936

0.674

0.499

0.344

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

UKOOA Code (EVA)

YD30B

YD30C

YD30D

YD30F

YD402

YD403

YD404

YD406

YD410

YD416

YD425

YD435

YD450

YD470

UKOOA Code (CSP)

XD30B

XD30C

XD30D

XD30F

XD402

XD403

XD404

XD406

XD410

XD416

XD425

XD435

XD450

XD470

Multicore Armoured Power/Control Cables - Table 4/5 Cable

4 x 95

4 x 120

4 x 150

4 x 185

4 x 240

4 x 300

5 x 1.5

5 x 2.5

5x4

7 x 1.5

7 x 2.5

7x4

10 x 1.5

10 x 2.5

Stranding mm

37/1.78

37/2.03

37/2.25

37/2.52

61/2.25

61/2.52

7/0.53

7/0.67

7/0.85

7/0.53

7/0.67

7/0.85

7/0.53

7/0.67

Insulation Thickness mm

1.6

1.6

1.8

2

2.2

2.4

0.8

0.8

1

0.8

0.8

1

0.8

0.8

Thickness of Inner Sheath mm

-

-

-

-

-

-

-

-

-

1.2

1.2

-

-

-

Diameter over Inner Sheath (min/max) mm

47.2/49.2

49.9/51.9

55.1/57.1

61.1/63.1

69.1/71.1

76.7/78.7

13.1/15.1

14.4/16.4

17.4/19.4

12.7/14.7

15.9/17.9

-

-

0.3

Diameter of Armour/Braid mm

0.45

0.45

0.45

0.45

0.45

0.45

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Thickness of Outer Sheath mm

-

-

-

-

-

-

-

-

-

1.3

1.4

-

-

-

Overall Diameter (min/max) mm

53.3/55.3

58.4/60.4

64.1/66.1

70.4/72.4

79.1/81.1

87.3/89.3

16.3/18.3

17.6./19.6

21.0/23.0

17.6/19.6

19.3./21.3

22.7/24.7

23.3/25.3

24.1./26.1

Gland Size

E

E

F

F

G

G

A

A

B

A

B

B

B

C

Weight kg/km

5700

6900

8200

10260

13200

16300

420

550

720

520

600

800

720

810

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

85 100

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/– mH/km

0.259

0.254

0.251

0.25

0.244

0.243

0.391

0.371

0.353

0.391

0.371

-

-

-

Capacitance – μF/KM

0.286

0.303

0.315

0.323

0.348

0.357

0.112

0.126

0.14

0.112

0.126

-

-

-

DC Resistance max @ 20°c - Ώ/km

0.195

0.154

0.126

0.1

0.0762

0.0607

12.2

7.56

4.7

12.2

7.56

-

-

-

DC Resistance max @ 90°c - Ώ/km

0.271

0.214

0.175

0.14

0.108

0.087

15.555

9.639

5.993

15.555

9.639

-

-

Black

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

UKOOA Code (EVA)

YD495

YD40A

YD40B

YD40C

YD40D

YD40E

YD502

YD503

YD504

YD702

YD703

-

-

-

UKOOA Code (CSP)

XD495

XD40A

XD40B

XD40C

XD40D

XD40E

XD502

XD503

XD504

XD702

XD703

-

-

-

Datasheet Ref: OFS-BS-PC-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000 V Fire Resistant

Offshore Power Cables to BS6883 Specification

Multicore Armoured Power/Control Cables - Table 5/5 Cable

12 x 1.5

12x2.5

19x1.5

19x2.5

27 x 1.5

27 x 2.5

30 x 1.5

30 x 2.5

37 x 1.5

37 x 2.5

48 x 1.5

48 x 2.5

Stranding mm

7/0.53

7/0.67

7/0.53

7/0.67

7/0.53

7/0.67

7/0.53

7/0.67

7/0.53

7/0.67

7/0.53

7/0.67

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.3

1.4

-

1.5

-

1.7

-

-

-

-

-

-

Diameter over Inner Sheath (min/max) mm

18.6/20.6

20.8/22.8

23.3/25.3

25.8/27.8

28.0/30.0

31.0/33.0

-

-

31.01/33.01

34.9/36.9

-

0.45

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.3

0.45

0.3

0.45

0.45

0.45

0.45

Thickness of Outer Sheath mm

1.5

1.6

-

1.7

-

1.9

-

-

-

-

-

-

Overall Diameter (min/max) mm

22.2/24.2

24.6/26.6

27.1/29.1

29.8/31.8

32.2/34.2

35.7/37.7

33.2/35.2

36.9/38.9

35.72/37.72

39.8/41.8

40.67/42.67

45.3/47.3

Gland Size

A

C

C

C

C2

C2

C2

C2

C2

D

D

D

Weight kg/km

850

950

1100

1400

1500

1800

1950

2150

2700

2950

3500

3860

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85 100

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

Inductance/– mH/km

0.391

0.371

0.391

0.371

0.391

0.371

-

-

0.391

0.371

-

-

Capacitance – μF/KM

0.112

0.126

0.112

0.126

0.112

0.126

-

-

0.112

0.126

-

-

DC Resistance max @ 20°c - Ώ/km

12.2

7.56

12.2

7.56

12.2

7.56

-

-

12.2

7.56

-

DC Resistance max @ 90°c - Ώ/km

15.555

9.639

15.555

9.639

15.555

9.639

-

-

15.555

9.639

-

-

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

UKOOA Code (EVA)

YDA02

YDA03

YDB02

YDB03

YDC02

YDC03

-

-

YDD02

YDD03

-

-

UKOOA Code (CSP)

XDA02

XDA03

XDB02

XDB03

XDC02

XDC03

-

-

XDD02

XDD03

-

-

Datasheet Ref: OFS-BS-PC-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


Section 3 Medium Voltage Power Cables to BS6883 Specification

FLAME RETARDANT

FPAL Verify

Verified No.10049350

ABS

3


BS6883 3.8/6.6kV Flame Retardant

NEK606

Medium Voltage Power Cable to BS6883 Specification

BS6883 – Power CablesSingle Core Armoured:

Applicable Standards IEEE

BS6883 / IEC 60092-3 BS7655-1.2 BS EN 12166 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to BS6360

IEC

Application This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.

Conductor Identification One Core – Black New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Stranded Class 2 Tinned Annealed Copper Conductor to BS6360

(2) Conductor Screen:

Semi-conductive tape or an extruded layer of semi-conductive compound

(3) Insulation:

Halogen Free Ethylene Propylene Rubber (EPR) Complying with BS7655-1.2 Type GP5

(4) Insulation Screen:

Semi-Conductive tape or an extruded layer of semi-conductive compound

(5) Metallic Screen:

Copper Tape - Note the tape may be tinned or plain

(6) Bedding:

CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type MA PET Tape

(7) Armour:

Singlecore- Tinned phosphor bronze wire braid to BS2873-PB102 (now BS EN 12166) PET Tape

(8) Outer Sheah:

CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type MA

Datasheet Ref: OFS-BS-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


3.8/6.6kV Flame Retardant

Medium Voltage Power Cables to BS6883 Specification

Single Core Armoured Power Cables Number of cores

No.

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Nominal area of conductor

mm²

16

25

35

50

70

95

120

150

185

240

300

400

500

630

Insulation radial thickness

mm

3.00

3.00

3.00

3.00

3.00

3.00

3.00

3.00

3.00

3.00

3.00

3.00

3.00

3.00

Inner sheath radial thickness

mm

1.30

1.30

1.40

1.40

1.50

1.60

1.60

1.70

1.80

1.90

2.00

2.10

2.30

2.40

Tinned phosphor bronze wire braid diameter

mm

0.30

0.30

0.30

0.30

0.30

0.30

0.30

0.45

0.45

0.45

0.45

0.45

0.45

0.45

Outer sheath radial thickness

mm

1.40

1.50

1.50

1.60

1.70

1.80

1.80

1.90

2.00

2.10

2.20

2.40

2.50

2.70

Overall diameter (Nom)

mm

21.30

23.00

24.00

25.40

27.40

29.60

31.30

33.80

36.00

40.40

43.40

47.30

51.70

55.90

Cable weight (Nom) Internal bending radius (Min)

Kg/Km

-

-

-

-

-

-

-

-

-

-

-

-

-

-

mm

448

484

504

530

572

614

652

704

746

836

900

978

1070

1154

Braid resistance @ 20°C (Max)

/Km

11.76

10.16

10.16

8.91

8.07

8.07

8.51

6.91

6.91

5.89

5.37

5.37

5.16

3.58

Armour gross cross sectional area

mm²

11.88

13.57

13.57

15.27

16.96

16.96

16.96

26.72

26.72

30.54

34.35

34.35

38.17

45.80

d.c. conductor resistance @ 20°C (Max)

/Km

1.16

0.734

0.529

0.391

0.270

0.195

0.154

0.126

0.100

0.0762

0.0607

0.0475

0.0369

0.0286

a.c. conductor resistance @ 20°C (Max)

/Km

1.48

0.936

0.675

0.499

0.345

0.249

0.197

0.162

0.129

0.0996

0.0805

0.0646

0.0523

0.0429

Inductive reactance @ 60 Hz +

/Km

0.198

0.179

0.173

0.165

0.157

0.148

0.144

0.142

0.138

0.129

0.126

0.122

0.120

0.117

Impedance @ 60 Hz

/Km

1.49

0.953

0.697

0.526

0.379

0.290

0.244

0.215

0.189

0.163

0.150

0.138

0.131

0.124

DC voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Single phase voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Three phase voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

-

-

-

-

A

95

125

155

190

240

290

340

385

440

520

590

670

720

780 62.90

Continuous current carrying capacity @ 45°C * Conductor short circuit symmetrical fault 90°C - 160°C for 1 sec

kA rms

-

-

-

-

6.99

9.49

12.00

15.00

18.50

24.00

30.00

40.00

49.90

90°C - 250°C for 1 sec Braid short circuit asymmetrical earth fault 80°C - 220°C for 1 sec

kA rms

2.29

3.58

5.01

7.15

-

-

-

-

-

-

-

-

-

-

kA rms

0.724

0.828

0.828

0.931

1.035

1.035

1.035

1.630

1.630

1.863

2.096

2.096

2.328

2.794

UKOOA Code

MA116 MA125 MA135 MA150 MA170 MA195 MA10A MA10B MA10C MA10D MA10E MA10F MA10G MA10H

Datasheet Ref: OFS-BS-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 3.8/6.6kV Flame Retardant

BS6883 – Power CablesMulti Core Armoured:

NEK606

Medium Voltage Power Cable to BS6883 Specification

Applicable Standards

IEEE

BS6883 / IEC 60092-3 BS7655-1.2 BS EN 10257-1 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to BS6360

Application IEC

This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.

Conductor Identification The cores of three-core cables shall be identified by one of the following methods a) printing 1,2,3 on the semiconducting insulation screen tape b) coloured insulation (red, yellow, blue) c) coloured tapes (red, yellow, blue) d) numbered tapes e) printing colours (red, yellow, blue) on the semi-conducting insulation screen tape

Note: picture is for illustration purposes only

New harmonised core colours or project specified colours can be supplied upon special request

Construction

Specifications

(1) Conductor:

Stranded Class 2 Tinned Annealed Copper Conductor to BS6360

(2) Conductor Screen:

Semi-conductive tape or an extruded layer of semi-conductive compound

(3) Insulation:

Halogen Free Ethylene Propylene Rubber (EPR) Complying with BS7655-1.2 Type GP5

(4) Insulation Screen:

Semi-Conductive tape or an extruded layer of semi-conductive compound

(5) Metallic Screen:

Copper Tape - Note the tape may be tinned or plain

(6) Bedding:

CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type MB PET Tape

(7) Armour:

3 Core- Galvanised Mild Steel Wire Braid to BS EN 10257-1 PET Tape

(8) Outer Sheah:

CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type MB

Datasheet Ref: OFS-BS-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


3.8/6.6kV Flame Retardant

Medium Voltage Power Cables to BS6883 Specification

Multi Core Armoured Power Cables Number of cores

No.

3

3

3

3

3

3

3

3

3

3

3

Nominal area of conductor

mm²

16

25

35

50

70

95

120

150

185

240

300

Insulation radial thickness

mm

3.00

3.00

3.00

3.00

3.00

3.00

3.00

3.00

3.00

3.00

3.00

Inner sheath radial thickness

mm

1.80

2.00

2.00

2.20

2.30

2.50

2.60

2.70

2.90

3.10

3.30

Galvanised steel wire braid diameter

mm

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

Outer sheath radial thickness

mm

2.10

2.20

2.30

2.40

2.60

2.80

2.90

3.10

3.20

3.50

3.70

Overall diameter (Nom)

mm

39.10

43.10

45.10

48.20

52.60

57.30

60.80

64.60

69.00

78.90

85.10 1313

Cable weight (Nom)

Kg/Km mm

599

671

695

747

815

884

938

999

1064

1215

Braid resistance @ 20°C (Max)

Ω/Km

7.19

7.19

6.50

6.50

6.30

4.37

4.09

4.09

3.36

3.30

2.96

Armour gross cross sectional area

mm²

30.54

30.54

34.35

34.35

38.17

45.80

51.53

51.53

57.26

62.98

68.71

d.c. conductor resistance @ 20°C (Max)

Ω/Km

1.16

0.734

0.529

0.391

0.270

0.195

0.154

0.126

0.100

0.0762

0.0607

a.c. conductor resistance @ 20°C (Max)

Ω/Km

1.48

0.936

0.675

0.499

0.345

0.250

0.198

0.163

0.130

0.101

0.0825

Inductive reactance @ 60 Hz +

Ω/Km

0.152

0.136

0.131

0.125

0.119

0.112

0.109

0.106

0.103

0.0981

0.0958

Internal bending radius (Min)

Ω/Km

1.49

0.946

0.687

0.515

0.365

0.274

0.226

0.194

0.166

0.141

0.126

DC voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

-

Single phase voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

-

Three phase voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

-

A

67

89

105

135

170

205

240

270

305

365

415 30.00

Impedance @ 60 Hz

Continuous current carrying capacity @ 45°C * Conductor short circuit symmetrical fault 90°C - 160°C for 1 sec

kA rms

-

-

-

-

6.99

9.49

12.00

15.00

18.50

24.00

90°C - 250°C for 1 sec Braid short circuit asymmetrical earth fault 80°C - 220°C for 1 sec UKOOA Code

kA rms

2.29

3.58

5.01

7.15

-

-

-

-

-

-

-

kA rms

1.527

1.527

1.718

1.718

1.909

2.290

2.576

2.576

2.863

3.149

3.435

MB316 MB325 MB335 MB350 MB370 MB395 MB30A MB30B MB30C MB30D MB30E

Datasheet Ref: OFS-BS-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 6.35/11kV Flame Retardant

NEK606

Medium Voltage Power Cable to BS6883 Specification

BS6883 – Power CablesSingle Core Armoured:

Applicable Standards IEEE

BS6883 / IEC 60092-3 BS7655-1.2 BS EN 12166 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to BS6360

IEC

Application This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.

Conductor Identification One Core – Black New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Stranded Class 2 Tinned Annealed Copper Conductor to BS6360

(2) Conductor Screen:

Semi-conductive tape or an extruded layer of semi-conductive compound

(3) Insulation:

Halogen Free Ethylene Propylene Rubber (EPR) Complying with BS7655-1.2 Type GP5

(4) Insulation Screen:

Semi-Conductive tape or an extruded layer of semi-conductive compound

(5) Metallic Screen:

Copper Tape - Note the tape may be tinned or plain

(6) Bedding:

CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type PA PET Tape

(7) Armour:

Singlecore- Tinned phosphor bronze wire braid to BS2873-PB102 (now BS EN 12166) PET Tape

(8) Outer Sheah:

CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type PA

Datasheet Ref: OFS-BS-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


6.35/11kV Flame Retardant

Medium Voltage Power Cables to BS6883 Specification

Single Core Armoured Power Cables Number of cores

No.

1

1

1

1

1

1

Nominal area of conductor

mm²

16.00

25.00

35.00

50.00

70.00

95.00

Insulation radial thickness

mm

3.40

3.40

3.40

3.40

3.40

3.40

3.40

3.40

Inner sheath radial thickness

mm

1.30

1.40

1.40

1.50

1.50

1.60

1.70

1.70

Tinned phosphor bronze wire braid diameter

mm

0.30

0.30

0.30

0.30

0.30

0.30

0.45

Outer sheath radial thickness

mm

1.50

1.50

1.60

1.60

1.70

1.80

Overall diameter (Nom)

mm

22.30

24.10

25.10

26.40

28.30

30.50

Cable weight (Nom) Internal bending radius (Min)

1

1

1

1

1

1

1

1

240.00

300.00

400.00

500.00

630.00

3.40

3.40

3.40

3.40

3.40

3.40

1.80

1.90

2.00

2.10

2.30

2.40

0.45

0.45

0.45

0.45

0.45

0.45

0.45

1.90

2.00

2.00

2.20

2.30

2.40

2.50

2.70

33.30

34.90

36.80

41.60

44.50

48.20

52.10

56.40

120.00 150.00 185.00

Kg/Km

-

-

-

-

-

-

-

-

-

-

-

-

-

-

mm

470

504

524

552

588

634

692

724

764

864

920

994

1078

1162

Braid resistance @ 20°C (Max)

/Km

10.16

10.16

8.91

8.91

8.07

8.51

6.91

6.91

6.91

5.89

5.37

5.37

5.16

3.58

Armour gross cross sectional area

mm²

13.57

13.57

15.27

15.27

16.96

16.96

26.72

26.72

26.72

30.54

34.35

34.35

38.17

45.80

d.c. conductor resistance @ 20°C (Max)

/Km

1.16

0.734

0.529

0.391

0.270

0.195

0.154

0.126

0.100

0.0762

0.0607

0.0475

0.0369

0.0286

a.c. conductor resistance @ 20°C (Max)

/Km

1.48

0.936

0.675

0.499

0.345

0.249

0.197

0.162

0.129

0.0995

0.0804

0.0646

0.0521

0.0434

Inductive reactance @ 60 Hz +

/Km

0.197

0.179

0.172

0.165

0.156

0.147

0.146

0.141

0.137

0.129

0.126

0.121

0.118

0.109

Impedance @ 60 Hz

/Km

1.49

0.953

0.696

0.525

0.378

0.290

0.245

0.215

0.188

0.163

0.149

0.137

0.129

0.118

DC voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Single phase voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Three phase voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

-

-

-

-

A

95

125

155

190

240

290

340

385

440

520

590

670

720

780 62.90

Continuous current carrying capacity @ 45°C * Conductor short circuit symmetrical fault 90°C - 160°C for 1 sec

kA rms

-

-

-

-

6.99

9.49

12.00

15.00

18.50

24.00

30.00

40.00

49.90

90°C - 250°C for 1 sec Braid short circuit asymmetrical earth fault 80°C - 220°C for 1 sec

kA rms

2.29

3.58

5.01

7.15

-

-

-

-

-

-

-

-

-

-

kA rms

0.828

0.828

0.931

0.931

1.035

1.035

1.630

1.630

1.630

1.863

2.096

2.096

2.328

2.794

PA10E

PA10F

PA10G

PA10H

UKOOA Code

PA116 PA125 PA135 PA150 PA170 PA195 PA10A PA10B PA10C PA10D

Datasheet Ref: OFS-BS-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 6.35/11kV Flame Retardant

BS6883 – Power CablesMulti Core Armoured:

NEK606

Medium Voltage Power Cable to BS6883 Specification

Applicable Standards

IEEE

BS6883 / IEC 60092-3 BS7655-1.2 BS EN 10257-1 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to BS6360

Application IEC

This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.

Conductor Identification The cores of three-core cables shall be identified by one of the following methods a) printing 1,2,3 on the semiconducting insulation screen tape b) coloured insulation (red, yellow, blue) c) coloured tapes (red, yellow, blue) d) numbered tapes e) printing colours (red, yellow, blue) on the semi-conducting insulation screen tape

Note: picture is for illustration purposes only

New harmonised core colours or project specified colours can be supplied upon special request

Construction

Specifications

(1) Conductor:

Stranded Class 2 Tinned Annealed Copper Conductor to BS6360

(2) Conductor Screen:

Semi-conductive tape or an extruded layer of semi-conductive compound

(3) Insulation:

Halogen Free Ethylene Propylene Rubber (EPR) Complying with BS7655-1.2 Type GP5

(4) Insulation Screen:

Semi-Conductive tape or an extruded layer of semi-conductive compound

(5) Metallic Screen:

Copper Tape - Note the tape may be tinned or plain

(6) Bedding:

CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type PB PET Tape

(7) Armour:

3 Core- Galvanised Mild Steel Wire Braid to BS EN 10257-1 PET Tape

(8) Outer Sheah:

CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type PB

Datasheet Ref: OFS-BS-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


6.35/11kV Flame Retardant

Medium Voltage Power Cables to BS6883 Specification

Multi Core Armoured Power Cables Number of cores

No.

3

3

3

3

3

3

3

3

3

3

3

Nominal area of conductor

mm²

16

25

35

50

70

95

120

150

185

240

300

Insulation radial thickness

mm

3.40

3.40

3.40

3.40

3.40

3.40

3.40

3.40

3.40

3.40

3.40

Inner sheath radial thickness

mm

1.90

2.00

2.10

2.20

2.40

2.50

2.70

2.80

3.00

3.20

3.40

Galvanised steel wire braid diameter

mm

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

Outer sheath radial thickness

mm

2.10

2.30

2.40

2.50

2.70

2.80

3.00

3.10

3.30

3.60

3.80

Overall diameter (Nom)

mm

41.30

45.10

47.30

50.20

54.80

61.00

63.20

66.60

71.20

81.10

87.30 1343

Cable weight (Nom)

Kg/Km mm

642

695

734

777

848

914

977

1029

1097

1248

Braid resistance @ 20°C (Max)

Ω/Km

7.19

6.50

6.50

6.30

4.37

4.37

4.09

3.36

3.18

3.30

3.27

Armour gross cross sectional area

mm²

30.54

34.35

34.35

38.17

45.80

45.80

51.53

57.26

62.98

62.98

68.71

d.c. conductor resistance @ 20°C (Max)

Ω/Km

1.16

0.734

0.529

0.391

0.270

0.195

0.154

0.126

0.100

0.0762

0.0607

a.c. conductor resistance @ 20°C (Max)

Ω/Km

1.48

0.936

0.675

0.499

0.345

0.250

0.198

0.163

0.130

0.101

0.0823

Inductive reactance @ 60 Hz +

Ω/Km

0.157

0.141

0.135

0.129

0.122

0.116

0.112

0.109

0.106

0.100

0.0979

Impedance @ 60 Hz

Ω/Km

1.49

0.947

0.688

0.516

0.366

0.275

0.227

0.196

0.168

0.142

0.128

DC voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

-

Single phase voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

-

Three phase voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

-

A

67

89

105

135

170

205

240

270

305

365

415 30.00

Internal bending radius (Min)

Continuous current carrying capacity @ 45°C * Conductor short circuit symmetrical fault 90°C - 160°C for 1 sec

kA rms

-

-

-

-

6.99

9.49

12.00

15.00

18.50

24.00

90°C - 250°C for 1 sec Braid short circuit asymmetrical earth fault 80°C - 220°C for 1 sec UKOOA Code

kA rms

2.29

3.58

5.01

7.15

-

-

-

-

-

-

-

kA rms

1.527

1.718

1.718

1.909

2.290

2.290

2.576

2.863

3.149

3.149

3.435

PB316 PB325 PB335 PB350 PB370 PB395 PB30A PB30B PB30C PB30D

PB30E

Datasheet Ref: OFS-BS-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 8.7/15kV Flame Retardant

NEK606

Medium Voltage Power Cable to BS6883 Specification

BS6883 – Power CablesSingle Core Armoured:

Applicable Standards IEEE

BS6883 / IEC 60092-3 BS7655-1.2 BS EN 12166 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to BS6360

IEC

Application This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.

Conductor Identification One Core – Black New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Stranded Class 2 Tinned Annealed Copper Conductor to BS6360

(2) Conductor Screen:

Semi-conductive tape or an extruded layer of semi-conductive compound

(3) Insulation:

Halogen Free Ethylene Propylene Rubber (EPR) Complying with BS7655-1.2 Type GP5

(4) Insulation Screen:

Semi-Conductive tape or an extruded layer of semi-conductive compound

(5) Metallic Screen:

Copper Tape - Note the tape may be tinned or plain

(6) Bedding:

CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type HA PET Tape

(7) Armour:

Singlecore- Tinned phosphor bronze wire braid to BS2873-PB102 (now BS EN 12166) PET Tape

(8) Outer Sheah:

CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type HA

Datasheet Ref: OFS-BS-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


8.7/15kV Flame Retardant

Medium Voltage Power Cables to BS6883 Specification

Single Core Armoured Power Cables Number of cores

No.

1

1

1

1

1

Nominal area of conductor

mm²

25.00

35.00

50.00

70.00

95.00

Insulation radial thickness

mm

4.50

4.50

4.50

4.50

4.50

4.50

Inner sheath radial thickness

mm

1.50

1.50

1.50

1.60

1.70

1.80

Tinned phosphor bronze wire braid diameter

mm

0.30

0.30

0.30

0.30

0.45

Outer sheath radial thickness

mm

1.60

1.70

1.70

1.80

Overall diameter (Nom)

mm

26.50

27.60

28.70

30.80

Cable weight (Nom) Internal bending radius (Min)

1

1

1

1

1

1

1

1

185.00

240.00

300.00

400.00

500.00

630.00

4.50

4.50

4.50

4.50

4.50

4.50

4.50

1.80

1.90

2.00

2.10

2.20

2.40

2.50

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

1.90

2.00

2.10

2.10

2.20

2.40

2.50

2.60

2.80

34.00

35.70

37.40

39.30

43.90

47.00

50.60

54.60

58.80

120.00 150.00

Kg/Km

-

-

-

-

-

-

-

-

-

-

-

-

-

mm

554

574

598

638

706

740

774

814

910

970

1044

1128

1212

Braid resistance @ 20°C (Max)

/Km

8.91

8.07

8.07

8.51

6.91

6.91

6.91

5.89

5.37

5.37

5.16

3.58

3.58

Armour gross cross sectional area

mm²

15.27

16.96

16.96

16.96

26.72

26.72

26.72

30.54

34.35

34.35

38.17

45.80

45.80

d.c. conductor resistance @ 20°C (Max)

/Km

0.734

0.529

0.391

0.270

0.195

0.154

0.126

0.100

0.0762

0.0607

0.0475

0.0369

0.0286

a.c. conductor resistance @ 20°C (Max)

/Km

0.936

0.675

0.499

0.345

0.249

0.197

0.162

0.129

0.0994

0.0803

0.0644

0.0519

0.0425

Inductive reactance @ 60 Hz +

/Km

0.186

0.179

0.171

0.162

0.156

0.151

0.146

0.141

0.133

0.129

0.124

0.122

0.118

Impedance @ 60 Hz

/Km

0.954

0.698

0.527

0.381

0.294

0.248

0.218

0.191

0.166

0.152

0.140

0.132

0.126

DC voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

-

-

-

Single phase voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

-

-

-

Three phase voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

-

-

-

A

125

155

190

240

290

340

385

440

520

590

670

720

780 62.90

Continuous current carrying capacity @ 45°C * Conductor short circuit symmetrical fault 90°C - 160°C for 1 sec

kA rms

-

-

-

6.99

9.49

12.00

15.00

18.50

24.00

30.00

40.00

49.90

90°C - 250°C for 1 sec Braid short circuit asymmetrical earth fault 80°C - 220°C for 1 sec

kA rms

3.58

5.01

7.15

-

-

-

-

-

-

-

-

-

-

kA rms

0.931

1.035

1.035

1.035

1.630

1.630

1.630

1.863

2.096

2.096

2.328

2.794

2.794

HA10E

HA10F

UKOOA Code

HA125 HA135 HA150 HA170 HA195 HA10A HA10B HA10C HA10D

HA10G HA10H

Datasheet Ref: OFS-BS-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 8.7/15kV Flame Retardant

BS6883 – Power CablesMulti Core Armoured:

NEK606

Medium Voltage Power Cable to BS6883 Specification

Applicable Standards

IEEE

BS6883 / IEC 60092-3 BS7655-1.2 BS EN 10257-1 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to BS6360

Application IEC

This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.

Conductor Identification The cores of three-core cables shall be identified by one of the following methods a) printing 1,2,3 on the semiconducting insulation screen tape b) coloured insulation (red, yellow, blue) c) coloured tapes (red, yellow, blue) d) numbered tapes e) printing colours (red, yellow, blue) on the semi-conducting insulation screen tape

Note: picture is for illustration purposes only

New harmonised core colours or project specified colours can be supplied upon special request

Construction

Specifications

(1) Conductor:

Stranded Class 2 Tinned Annealed Copper Conductor to BS6360

(2) Conductor Screen:

Semi-conductive tape or an extruded layer of semi-conductive compound

(3) Insulation:

Halogen Free Ethylene Propylene Rubber (EPR) Complying with BS7655-1.2 Type GP5

(4) Insulation Screen:

Semi-Conductive tape or an extruded layer of semi-conductive compound

(5) Metallic Screen:

Copper Tape - Note the tape may be tinned or plain

(6) Bedding:

CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type HB PET Tape

(7) Armour:

3 Core- Galvanised Mild Steel Wire Braid to BS EN 10257-1 PET Tape

(8) Outer Sheah:

CSP – SW2 or EVA - SW4 Thermo set Rubber Compound Complying with BS7655, incorporating enhanced Oil resistance, minimum tear resistance – UKOOA type HB

Datasheet Ref: OFS-BS-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


8.7/15kV Flame Retardant

Medium Voltage Power Cables to BS6883 Specification

Multi Core Armoured Power Cables Number of cores

No.

3

3

3

3

3

3

3

3

3

3

Nominal area of conductor

mm²

25

35

50

70

95

120

150

185

240

300

Insulation radial thickness

mm

4.50

4.50

4.50

4.50

4.50

4.50

4.50

4.50

4.50

4.50

Inner sheath radial thickness

mm

2.20

2.30

2.40

2.60

2.70

2.90

3.00

3.20

3.40

3.60

Galvanised steel wire braid diameter

mm

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

0.45

Outer sheath radial thickness

mm

2.50

2.60

2.70

2.90

3.00

3.20

3.30

3.50

3.80

4.00

Overall diameter (Nom)

mm

50.50

52.90

55.70

60.10

64.60

68.30

72.10

76.70

86.60

92.80 1431

Kg/Km

Cable weight (Nom)

mm

780

819

863

929

999

1053

1115

1184

1334

Braid resistance @ 20°C (Max)

Ω/Km

6.30

6.30

4.37

4.09

4.09

3.36

3.18

3.30

2.96

3.27

Armour gross cross sectional area

mm²

38.17

38.17

45.80

51.53

51.53

57.26

62.98

62.98

68.71

68.71

Internal bending radius (Min)

d.c. conductor resistance @ 20°C (Max)

Ω/Km

0.734

0.529

0.391

0.270

0.195

0.154

0.126

0.100

0.0762

0.0607

a.c. conductor resistance @ 20°C (Max)

Ω/Km

0.936

0.675

0.499

0.345

0.250

0.198

0.162

0.130

0.101

0.0819

Inductive reactance @ 60 Hz +

Ω/Km

0.151

0.145

0.138

0.131

0.123

0.119

0.116

0.112

0.106

0.103

Impedance @ 60 Hz

Ω/Km

0.948

0.690

0.518

0.369

0.278

0.231

0.199

0.172

0.146

0.132

DC voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

Single phase voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

Three phase voltage drop

mV/A/M

-

-

-

-

-

-

-

-

-

-

A

89

105

135

170

205

240

270

305

365

415 30.00

Continuous current carrying capacity @ 45°C * Conductor short circuit symmetrical fault 90°C - 160°C for 1 sec

kA rms

-

-

-

6.99

9.49

12.00

15.00

18.50

24.00

90°C - 250°C for 1 sec Braid short circuit asymmetrical earth fault 80°C - 220°C for 1 sec

kA rms

3.58

5.01

7.15

-

-

-

-

-

-

-

kA rms

1.909

1.909

2.290

2.576

2.576

2.863

3.149

3.149

3.435

3.435

HB325 HB335 HB350 HB370 HB395 HB30A HB30B HB30C HB30D

UKOOA Code

HB30E

Datasheet Ref: OFS-BS-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


Section 4 Offshore Instrumentation Cables to NEK 606 Specification

RFOU FLAME RETARDANT

FPAL Verify

Verified No.10049350

ABS

4


BS6883

Offshore Instrumentation Cables to NEK606 Specification

RFOU(C) Pairs/Triples Armoured Cables – Collectively Screened:

NEK606

150/250V Flame Retardant

Applicable Standards

IEEE

NEK 606 / IEC 60092-3 IEC 60092-351 IEC 60332 part 3 (Category A) IEC 60092-359 Stranded class 2 or tinned annealed copper conductors to IEC60228

Application IEC

This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.

Conductor Identification

Single Pair: Black/ Light Blue Triples: Black/ Light Blue/ Brown New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Annealed Copper Conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Insulation:

(R) EPR Complying with IEC60092-351

(3) Collective Screen:

Aluminium or Copper Mylar Tape Screen in contact with Tinned Copper drain wire

(4) Bedding:

(F) - Flame Retardant Halogen Free Compound, PETP-tape

(5) Armour:

(O) - Tinned Copper Wire Braid to NVE FEA-M 1238.5, PETP-tape

(6) Outer Sheath:

(U) - SHF2 dual Compound thermoset rubber - IEC60092-359 Type SHF2, Dual rated as being Both halogen free and mud resistant in accordance with NEK606, and meets cold bend and Impact test (-20C) cross sectional area C22.2.

Datasheet Ref: OFS-NK-INS-CS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250V Flame Retardant

Offshore Instrumentation Cables to NEK606 Specification

RFOU(c) Pairs/Triples Armoured Cables - Table 1/2 Cable

2x2x0.75

4x2x0.75

8x2x0.75 12x2x0.75 16x2x0.75 24x2x0.75

2x2x1.5

4x2x1.5

8x2x1.5

12x2x1.5

16x2x1.5

24x2x1.5

Stranding mm

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.1

1.1

1.1

1.3

1.4

1.6

1.1

1.1

1.1

1.3

1.4

1.8

Diameter over Inner Sheath (min/max) mm

10.5/12.5

12.5/14.5

17.5/19.5

19.5/22.5

21.0./24.0

26.0/29.0

12.5/14.5

14.5/16.5

19.5/22.5

22.0/25.0

24.5/27.5

29.5/33.5 0.3

Diameter of Armour/Braid mm

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Thickness of Outer Sheath mm

1.2

1.3

1.4

1.5

1.6

1.8

1.3

1.4

1.6

1.7

1.8

2.1

Overall Diameter (min/max) mm

14.0/16.0

16.5/18.5

21.0/24.0

23.5/26.5

25.5/28.5

30.5/34.5

16.0/18.0

18.5/20.5

23.5/26.5

27.0/30.0

29.0/33.0

35.5/39.5

Gland Size

O

A

B

C

C

C2

A

A

C

C

C

C2

Weight kg/km

310

430

700

900

1080

1510

430

560

930

1260

1550

2230

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/ Resistance – mH/km

0.75

0.75

0.75

0.75

0.75

0.75

0.68

0.68

0.68

0.68

0.68

0.68

Capacitance – nF/KM

80

80

80

80

80

80

90

90

90

90

90

90

DC Resistance @ 20°c – ohms/km

24.8

24.8

24.8

24.8

24.8

24.8

12.2

12.2

12.2

12.2

12.2

12.2

Sheath Colour

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/ Blue

Grey/ Blue

Grey/ Blue

RFOU(c) Pairs/Triples Armoured Cables - Table 2/2 Cable

2x3x0.75

4x3x0.75

Stranding mm

7/0.37

7/0.37

8x3x0.75 12x3x0.75 16x3x0.75 24x3x0.75 7/0.37

2x3x1.5

4x3x1.5

8x3x1.5

12x3x1.5

16x3x1.5

24x3x1.5

7/0.37

7/0.37

7/0.37

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53 0.8

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.1

1.1

1.1

1.3

1.4

1.8

1.1

1.1

1.1

1.3

1.4

1.8

Diameter over Inner Sheath (min/max) mm

12.0/14.0

14.0/16.0

18.5/21.5

21.5/24.5

24.0./27.0

29.0/33.0

14.0/16.0

16.0/18.0

21.5/24.5

25.5/28.5

28.0/31.0

34.0/38.0 0.3

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Thickness of Outer Sheath mm

1.3

1.3

1.5

1.6

1.7

2

1.4

1.4

1.7

1.8

1.9

2.2

Overall Diameter (min/max) mm

15.5/17.5

17.5/19.5

22.5/25.5

26.5/29.5

28.0/32.0

34.5/38.5

17.5/19.5

19.5/22.5

26.0/29.0

29.5/33.5

33.0/37.0

39.5/44.5

Gland Size

A

A

B

C

C

C2

A

B

C

C2

C2

D

Weight kg/km

410

530

860

1180

1430

2120

520

710

1230

1650

2050

3040

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/ Resistance – mH/km

0.75

0.75

0.75

0.75

0.75

0.75

0.68

0.68

0.68

0.68

0.68

0.68

Capacitance – nF/KM

80

80

80

80

80

80

90

90

90

90

90

90

DC Resistance @ 20°c – Ohms/km

24.8

24.8

24.8

24.8

24.8

24.8

12.2

12.2

12.2

12.2

12.2

12.2

Sheath Colour

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/ Blue

Grey/ Blue

Grey/ Blue

Datasheet Ref: OFS-NK-INS-CS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883

Offshore Instrumentation Cables to NEK606 Specification

RFOU(i) Pairs/Triples Armoured Cables – Individually Screened:

NEK606

150/250V Flame Retardant

Applicable Standards IEEE

NEK 606 / IEC 60092-3 IEC 60092-351 IEC 60332 part 3 (Category A) IEC 60092-359 Stranded class 2 or tinned annealed copper conductors to IEC60228

Application IEC

This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.

Conductor Identification Single Pair: Black/ Light Blue Triples: Black/ Light Blue/ Brown New harmonised core colours or project specified colours can be supplied upon special request

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Annealed Copper Conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Insulation:

(R) EPR Complying with IEC60092-351

(3) Individual Screen:

Aluminium or Copper Mylar Tape Screen in contact with Tinned Copper drain wire

(4) Bedding:

(F) - Flame Retardant Halogen Free Compound, PETP-tape

(5) Armour:

(O) - Tinned Copper Wire Braid to NVE FEA-M 1238.5, PETP-tape

(6) Outer Sheath:

(U) - SHF2 dual Compound thermoset rubber - IEC60092-359 Type SHF2, Dual rated as being Both halogen free and mud resistant in accordance with NEK606, and meets cold bend and Impact test (-20C) cross sectional area C22.2.

Datasheet Ref: OFS-NK-INS-IS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250V Flame Retardant

Offshore Instrumentation Cables to NEK606 Specification

RFOU(i) Pairs/Triples Armoured Cables - Table 1/2 1x2x1.5

2x2x1.5

4x2x1.5

8x2x1.5

Stranding mm

Cable

1x2x0.75 2x2x0.75 4x2x0.75 8x2x0.75 12x2x0.75 16x2x0.75 24x2x0.75 7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.53

7/0.53

7/0.53

7/0.53

12x2x1.5 16x2x1.5 24x2x1.5 7/0.53

7/0.53

7/0.53

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.1

1.1

1.1

1.1

1.3

1.4

1.6

1.1

1.1

1.1

1.1

1.3

1.4

1.8

Diameter over Inner Sheath (min/max) mm

7.2/8.8

10.5/12.5

12.5/14.5

17.5/19.5

20.0./23.0

22.5/25.5

28.0/31.0

8.2/9.8

12.5/14.5

14.5/16.5

19.5/22.5

23.5/26.5

26.5/29.5

32.5/36.5 0.4

Diameter of Armour/Braid mm

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.2

0.3

0.3

0.3

0.3

0.3

Thickness of Outer Sheath mm

1.1

1.2

1.3

1.5

1.6

1.7

1.9

1.1

1.3

1.4

1.6

1.8

1.9

2.2

Overall Diameter (min/max) mm

10.0/12.0

14.0/16.0

16.5/18.5

21.0/24.0

24.5/27.5

27.0/30.0

33.0/37.0

11.0/13.0

16.0/18.0

18.5/20.5

24.0/27.0

28.0/32.0

31.0/35.0

38.0/43.0

Gland Size

O

O

A

B

C

C

C2

O

A

A

C

C

C2

D

Weight kg/km

200

330

470

790

1080

1330

1920

240

450

620

1070

1530

1860

2760

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/ Resistance – mH/km

0.75

0.75

0.75

0.75

0.75

0.75

0.75

0.68

0.68

0.68

0.68

0.68

0.68

0.68

Capacitance – nF/KM

90

90

90

90

90

90

90

110

110

110

110

110

110

110

DC Resistance @ 20°c – Ohms/km

24.8

24.8

24.8

24.8

24.8

24.8

24.8

12.2

12.2

12.2

12.2

12.2

12.2

12.2

Sheath Colour

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/ Blue

Grey/ Blue

Grey/ Blue

Grey/Blue

Grey/Blue

RFOU(i) Pairs/Triples Armoured Cables - Table 2/2 1x3x1.5

2x3x1.5

4x3x1.5

8x3x1.5

Stranding mm

Cable

1x3x0.75 2x3x0.75 4x3x0.75 8x3x0.75 12x3x0.75 16x3x0.75 24x3x0.75 7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.53

7/0.53

7/0.53

7/0.53

12x3x1.5 16x3x1.5 24x3x1.5 7/0.53

7/0.53

7/0.53

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.1

1.1

1.1

1.1

1.3

1.4

1.8

1.1

1.1

1.1

1.1

1.3

1.6

1.8

Diameter over Inner Sheath (min/max) mm

7.7/9.3

12.0/14.0

14.0/16.0

18.5/21.5

23.0./26.0

25.0/29.0

31.5/35.5

8.7/10.3

14.0/16.0

16.5/18.5

21.5/24.5

27.0/30.0

30.0/34.0

37.5/41.5 0.4

Diameter of Armour/Braid mm

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.3

0.3

0.3

0.3

0.3

Thickness of Outer Sheath mm

1.1

1.3

1.4

1.6

1.7

1.8

2

1.1

1.4

1.5

1.7

1.9

2

2.3

Overall Diameter (min/max) mm

10.5/12.5

15.5/17.5

18.0/20.0

23.0/26.0

27.5/30.5

30.0/34.0

37.5/41.5

12.0/14.0

18.0/20.0

20.0/23.0

26.5/29.5

31.5/35.5

35.5/39.5

43.5/48.5

Gland Size

O

A

A

B

C

C2

D

O

A

B

C

C2

C2

D

Weight kg/km

210

420

560

950

1350

1630

2550

300

550

780

1390

1970

2570

3790

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/ Resistance – mH/km

0.75

0.75

0.75

0.75

0.75

0.75

0.75

0.68

0.68

0.68

0.68

0.68

0.68

0.68

Capacitance – nF/KM

90

90

90

90

90

90

90

110

110

110

110

110

110

110

DC Resistance @ 20°c – Ohms/km

24.8

24.8

24.8

24.8

24.8

24.8

24.8

12.2

12.2

12.2

12.2

12.2

12.2

12.2

Sheath Colour

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/ Blue

Grey/ Blue

Grey/ Blue

Grey/Blue

Grey/Blue

Datasheet Ref: OFS-NK-INS-IS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


Section 4 Offshore Instrumentation Cables to NEK 606 Specification

BFOU FIRE RESISTANT

FPAL Verify

Verified No.10049350

ABS

4


BS6883

Offshore Instrumentation Cables to NEK 606 Specification

BFOU(i) Pairs/Triples Armoured Cables – Individually Screened:

NEK606

150/250 V Fire Resistant

Applicable Standards IEEE

NEK 606 / IEC 60092-3 IEC 60092-351 IEC 60331 part 3 (Category A) IEC-60092-359

Stranded class 2 or tinned annealed copper conductors to IEC60228

Application IEC

This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.

Conductor Identification Single Pair: Black/ Light Blue Triples: Black/ Light Blue/ Brown New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Annealed Copper Conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Fire Protection

Mica Glass Tape

(3) Insulation

(B) - EPR Complying with IEC60092-351

(4) Individual Screen

Aluminium or Copper Mylar Tape Screen in contact with Tinned Copper drain wire

(5) Bedding:

(F) - Flame Retardant Halogen Free Compound, PETP-tape

(6) Armour:

(O) - Tinned Copper Wire Braid to NVE FEA-M 1238.5, PETP-tape

(7) Outer Sheath:

(U) - SHF2 dual Compound thermo set rubber - IEC60092-359 Type SHF2, Dual rated as being Both halogen free and mud resistant in accordance with NEK606, and meets cold bend and Impact test (-20C) cross sectional area C22.2

Datasheet Ref: OFS-NK-INS-IS-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250 V Fire Resistant

Offshore Instrumentation Cables to NEK 606 Specification

BFOU(i) Pairs/Triples Armoured Cables - Table 1/3 Cable

1x2x0.75

2x2x0.75

4x2x0.75

8x2x0.75

12x2x0.75 16x2x0.75 24x2x0.75

1x2x1.5

2x2x1.5

4x2x1.5

8x2x1.5

12x2x1.5

Stranding mm

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.1

1.1

1.1

1.1

1.3

1.4

1.8

1.1

1.1

1.1

1.1

1.3

Diameter over Inner Sheath (min/max) mm

8.2/9.8

11.5/13.5

13.5/15.5

18.5/21.5

22.0./25.0

25.0/28.0

30.5/34.5

9.0/11.0

13.5/15.5

16.0/18.0

21.5/24.5

25.5/28.5

Diameter of Armour/Braid mm

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Thickness of Outer Sheath mm

1.1

1.3

1.4

1.6

1.7

1.8

2.1

1.1

1.4

1.5

1.7

1.9

Overall Diameter (min/max) mm

11.0/13.0

15.0/17.0

17.5/19.5

23.0/26.0

27.0/30.0

30.0/33.0

36.5/40.5

12.0/14.0

17.5/19.5

20.0/22.0

26.0/29.0

30.0/34.0

Gland Size

O

A

A

B

C

C

C2

O

A

B

C

C2

Weight kg/km

220

390

510

890

1250

1490

2210

250

510

690

1230

1670

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/ Resistance – mH/km

0.67

0.67

0.67

0.67

0.67

0.67

0.67

0.63

0.63

0.63

0.63

0.63

Capacitance – nF/KM

110

110

110

110

110

110

110

125

125

125

125

125

DC Resistance @ 20°c – Ohms/km

24.8

24.8

24.8

24.8

24.8

24.8

24.8

12.2

12.2

12.2

12.2

12.2

Sheath Colour

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/ Blue

Grey/ Blue

Grey/ Blue

BFOU(i) Pairs/Triples Armoured Cables - Table 2/3 Cable

16x2x1.5

24x2x1.5

1x2x2.5

Stranding mm

7/0.53

7/0.53

-

4x2x2.5

1x3x0.75

2x3x0.75

4x3x0.75

8x3x0.75

7/0.37

7/0.37

7/0.37

7/0.37

12x3x0.75 16x3x0.75 24x3x0.75 7/0.37

7/0.37

7/0.37

1x3x1.5 7/0.53 0.8

Insulation Thickness mm

0.8

1

1

1

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.6

1.8

1.1

1.1

1.1

1.1

1.1

1.1

1.3

1.4

1.8

1.1

Diameter over Inner Sheath (min/max) mm

29.5/32.5

35.5/39.5

10.5/12.5

19.0/22.0

8.7/10.3

12.5/14.5

15.5/17.5

20.0/23.0

24.5/27.5

27.0/30.0

34.0/38.0

9.5/11.5 0.2

Diameter of Armour/Braid mm

0.3

0.4

0.2

0.3

0.2

0.3

0.3

0.3

0.3

0.3

0.4

Thickness of Outer Sheath mm

2

2.3

1.2

1.6

1.1

1.4

1.4

1.7

1.8

1.9

2.2

1.2

Overall Diameter (min/max) mm

34.0/38.0

41.5/46.5

13.5/15.5

23.0/26.0

11.5/13.5

16.5/18.5

18.5/21.5

24.5/27.5

29.0/33.0

31.5/35.5

39.5/44.5

12.5/14.5

Gland Size

C2

D

O

B

O

A

B

C

C

C2

D

O

Weight kg/km

2100

3020

330

950

240

440

620

1080

1540

1790

2720

300

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/ Resistance – mH/km

0.63

0.63

0.59

0.59

0.67

0.67

0.67

0.67

0.67

0.67

0.67

0.63

Capacitance – nF/KM

125

125

145

145

110

110

110

110

110

110

110

125

DC Resistance @ 20°c – Ohms/km

12.2

12.2

7.56

7.56

24.8

24.8

24.8

24.8

24.8

24.8

24.8

12.2

Sheath Colour

Grey/ Blue

Grey/ Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Datasheet Ref: OFS-NK-INS-IS-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250 V Fire Resistant

Offshore Instrumentation Cables to NEK 606 Specification

BFOU(i) Pairs/Triples Armoured Cables - Table 3/3 Cable

2x3x1.5

4x3x1.5

8x3x1.5

12x3x1.5

16x3x1.5

24x3x1.5

Stranding mm

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53 0.8

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.1

1.1

1.1

1.5

1.6

2

Diameter over Inner Sheath (min/max) mm

14.5/16.5

17.5/19.5

23.0/26.0

28.5/32.5

32.0/36.0

39.5/44.5

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.4

0.4

Thickness of Outer Sheath mm

1.5

1.6

1.8

2

2.2

2.5

Overall Diameter (min/max) mm

18.5/20.5

21.5/24.5

27.5/30.5

33.5/37.5

37.5/42.5

46.0/51.0

Gland Size

A

B

C

C2

D

D 3950

Weight kg/km

570

910

1440

2150

2700

Bend Radius - xOD

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

Inductance/ Resistance – mH/km

0.63

0.63

0.63

0.63

0.63

0.63

Capacitance – nF/KM

125

125

125

125

125

125

DC Resistance @ 20°c – Ohms/km

12.2

12.2

12.2

12.2

12.2

12.2

Sheath Colour

Grey/ Blue

Grey/ Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/ Blue

Datasheet Ref: OFS-NK-INS-IS-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883

Offshore Instrumentation Cables to NEK 606 Specification NEK606

150/250 V Fire Resistant

BFOU(c) Pairs/Triples Armoured Cables – Collectively Screened:

Applicable Standards

IEEE

NEK 606 / IEC 60092-3 IEC 60092-351 IEC 60331 part 3 (Category A) IEC-60092-359 Stranded class 2 or tinned annealed copper conductors to IEC60228

Application IEC

This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.

Conductor Identification Single Pair: Black/ Light Blue Triples: Black/ Light Blue/ Brown New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Annealed Copper Conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Fire Protection

Mica Glass Tape

(3) Insulation:

(B) - EPR Complying with IEC60092-351

(4) Collective Screen

Aluminium or Copper Mylar Tape Screen in contact with Tinned Copper drain wire

(5) Bedding:

(F) - Flame Retardant Halogen Free Compound, PETP-tape

(6) Armour:

(O) - Tinned Copper Wire Braid to NVE FEA-M 1238.5, PETP-tape

(7) Outer Sheath:

(U) - SHF2 dual Compound thermo set rubber - IEC60092-359 Type SHF2, Dual rated as being Both halogen free and mud resistant in accordance with NEK606, and meets cold bend and Impact test (-20C) cross sectional area C22.2

Datasheet Ref: OFS-NK-INS-CS-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250 V Fire Resistant

Offshore Instrumentation Cables to NEK 606 Specification

BFOU(c) Pairs/Triples Armoured Cables - Table 1/3 Cable

2x2x0.75

4x2x0.75

8x2x0.75

12x2x0.75 16x2x0.75 24x2x0.75

2x2x1.5

4x2x1.5

8x2x1.5

12x2x1.5

16x2x1.5

24x2x1.5 7/0.53

Stranding mm

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.1

1.1

1.1

1.3

1.4

1.8

1.1

1.1

1.1

1.3

1.4

1.8

Diameter over Inner Sheath (min/max) mm

11.5/13.5

13.5/15.5

22.5/25.5

21.0/24.0

22.5./25.5

28.0/31.0

13.0/15.0

15.0/17.0

21.0/24.0

24.0/27.0

26.0/29.0

32.0/36.0

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Thickness of Outer Sheath mm

1.3

1.4

1.5

1.6

1.7

2

1.4

1.4

1.7

1.8

1.9

2.2

Overall Diameter (min/max) mm

15.0/17.0

17.0/19.0

22.5/25.5

25.5/28.5

27.5/30.5

33.0/37.0

16.5/18.5

18.5/21.5

25.0/26.0

28.0/32.0

30.5/34.5

37.5/42.5

Gland Size

A

A

B

C

C

C2

A

B

B

C

C2

D

Weight kg/km

350

460

780

1040

1210

1730

450

610

1030

1390

1670

2440

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/ Resistance – mH/km

0.67

0.67

0.67

0.67

0.67

0.67

0.63

0.63

0.63

0.63

0.63

0.63

Capacitance – nF/KM

100

100

100

100

100

100

110

110

110

110

110

110

DC Resistance @ 20°c – Ohms/km

24.8

24.8

24.8

24.8

24.8

4.8

12.2

12.2

12.2

12.2

12.2

12.2

Sheath Colour

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/ Blue

Grey/ Blue

Grey/ Blue

BFOU(c) Pairs/Triples Armoured Cables - Table 2/3 Cable

2x2x2.5

4x2x2.5

8x2x2.5

16x2x2.5

24x2x2.5

2x3x0.75

4x3x0.75

8x3x0.75

12x3x0.75 16x3x0.75 24x3x0.75

Stranding mm

-

-

-

-

-

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

Insulation Thickness mm

1

1

1

1

1

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.1

1.1

1.1

1.6

2

1.1

1.1

1.1

1.3

1.4

1.8

Diameter over Inner Sheath (min/max) mm

15.5/17.5

18.0/21.0

25.0/28.0

31.5/35.5

39.0/44.0

13.0/15.0

15.5/17.5

20.0./23.0

24.0/27.0

26.0/29.0

32.0/36.0

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.4

0.4

0.3

0.3

0.3

0.3

0.3

0.4

Thickness of Outer Sheath mm

1.4

1.5

1.8

2.1

2.4

1.3

1.4

1.6

1.8

1.9

2.1

Overall Diameter (min/max) mm

19.5/21.5

22.0/25.0

29.0/33.0

37.5/41.5

45.5/50.5

17.0/19.0

19.0/22.0

24.5/27.5

28.5/32.5

30.5/34.5

37.5/41.5

Gland Size

B

B

C

D

D

A

B

C

C

C2

D 2340

Weight kg/km

210

420

560

2440

3540

470

610

1020

1380

1590

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

100

100

100

100

100

Inductance/ Resistance – mH/km

0.59

0.59

0.59

0.59

0.59

0.67

0.67

0.67

0.67

0.67

0.67

Capacitance – nF/KM

125

125

125

125

125

100

100

100

100

100

100

DC Resistance @ 20°c – Ohms/km

7.56

7.56

7.56

7.56

7.56

24.8

24.8

24.8

24.8

24.8

24.8

Sheath Colour

Grey/ Blue

Grey/ Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Datasheet Ref: OFS-NK-INS-CS-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250 V Fire Resistant

Offshore Instrumentation Cables to NEK 606 Specification

BFOU(c) Pairs/Triples Armoured Cables - Table 3/3 Cable

2x3x1.5

4x3x1.5

8x3x1.5

12x3x1.5

16x3x1.5

24x3x1.5

Stranding mm

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53 0.8

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.1

1.1

1.1

1.3

1.6

2

Diameter over Inner Sheath (min/max) mm

15.0/17.0

17.5/19.5

23.0/26.0

24.0/27.0

26.0/29.0

32.0/36.0

Diameter of Armour/Braid mm

0.3

0.3

0.3

0.3

0.4

0.4

Thickness of Outer Sheath mm

1.4

1.5

1.8

1.9

2.1

2.4

Overall Diameter (min/max) mm

18.5/21.5

21.0/24.0

28.0/31.0

32.5/36.5

35.5/39.5

43.5/48.5

Gland Size

B

B

C

C2

C2

D 3410

Weight kg/km

600

790

1350

1910

2330

Bend Radius - xOD

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

Short Circuit Rating, 1second – 250°c - A

100

100

100

100

100

100

Inductance/ Resistance – mH/km

0.63

0.63

0.63

0.63

0.63

0.63

Capacitance – nF/KM

110

110

110

110

110

110

DC Resistance @ 20°c – Ohms/km

12.2

12.2

12.2

12.2

12.2

12.2

Sheath Colour

Grey/Blue

Grey/ Blue

Grey/ Blue

Grey/Blue

Grey/Blue

Grey/ Blue

Datasheet Ref: OFS-NK-INS-CS-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


Section 5 Offshore Power & Control Cables to NEK 606 Specification

RFOU FLAME RETARDANT

FPAL Verify

Verified No.10049350

ABS

5


BS6883 RFOU Single and Multicore Armoured Cables:

NEK606

Offshore Power & Control Cables to NEK606 Specification Applicable Standards NEK 606 / IEC 60092-3 IEC 60092-351 IEC 60332 part 3 (Category A) IEC-60092-359 Stranded class 2 or tinned annealed copper conductors to IEC60228

IEEE

600/1000V Flame Retardant

Application

IEC

This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially where life may be endangered by smoke and noxious fumes, and where sensitive equipnment may be damaged by acid forming gases.

Conductor Identification

One core: Black Two cores: Blue- Brown Two cores+ earth Blue - Brown - Yellow/Green Three Cores: Brown - Black - Grey Three Cores + earth Brown - Black - Grey - Yellow/Green Four Cores: Blue - Brown - Black - Grey Four Cores + earth Blue - Brown - Black - Grey - Yellow/Green Five Cores Blue - Brown - Black - Grey - Black Above 5-cores : Black numbers on white base. New harmonised core colours or project specified colours can be supplied upon special request

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Annealed Copper Conductor to IEC60228

Fire Protection

None

(2) Insulation:

(R) - EPR Complying with IEC60092-351

(3) Bedding:

(F) - Flame Retardant Halogen Free Compound, PETP-tape

(4) Armour:

(O) - Tinned Copper Wire Braid to NVE FEA-M 1238.5, PETP-tape

(5) Outer Sheath:

(U) - SHF2 dual Compound thermoset rubber - IEC60092-359 Type SHF2, Dual rated as being Both halogen free and mud resistant in accordance with NEK606, and meets cold bend and Impact test (-20C) cross sectional area C22.2.

Datasheet Ref: OFS-NK-PC-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000V Flame Retardant

Offshore Power & Control Cables to NEK606 Specification

RFOU Single/Multicore Armoured Cables - Table 1/4 Cable

1 x16

1 x 25

1 x 35

1 x 50

1 x 70

1 x 95

1 x 120

1 x 150

1 x 185

1 x 240

1 x 300

2 x 1.5

2 x2.5

2x4 7/0.85

Stranding mm

7/1.70

19/1.35

19/1.53

19/1.78

19/2.14

37/1.78

37/2.03

37/2.25

37/2.52

61/2.25

61/2.52

7/0.53

7/0.67

Insulation Thickness mm

1

1.2

1.2

1.4

1.4

1.6

1.6

1.8

2

2.2

2.4

1

1

1

Thickness of Inner Sheath mm

1.1

1.1

1.1

1.1

1.1

1.1

1.2

1.2

1.2

1.2

1.2

1.1

1.1

1.1

Diameter over Inner Sheath (min/max) mm

9.0/11.0

10.5/12.5

12.0/14.0

14.0/16.0

16.0/18.0

18.0/20.0

19.0/22.0

21.5/24.5

23.5/26.5

26.5/29.5

28.5/32.5

9.0/11.0

9.5/11.5

11.0/13.0

Diameter of Armour/Braid mm

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.3

Thickness of Outer Sheath mm

1.2

1.2

1.3

1.4

1.4

1.5

1.6

1.6

1.7

1.8

1.9

1.2

1.2

1.3

Overall Diameter (min/max) mm

12.5/14.5

14.0/16.0

15.5/17.5

18.0/20.0

19.0/22.0

21.5/24.5

23.5/26.5

25.5/28.5

28.0/31.0

30.5/34.5

34.0/38.0

12.0/14.0

13.0/15.0

14.5/16.5

Gland Size

O

O

A

A

B

B

C

C

C

C2

C2

O

O

A

Weight kg/km

350

470

640

820

1060

1360

1680

2010

2430

3090

3790

260

300

400

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

85 560

Short Circuit Rating, 1second ampere

2240

3500

4900

7000

9800

13300

16800

21000

25900

33600

42000

210

350

Current Rating at 45°C - ampere

90

120

145

180

225

275

320

365

415

490

560

17

24

32

DC Resistance max @ 20°c - Ώ/km

1.16

0.734

0.529

0.391

0.27

0.195

0.154

0.126

0.1

0.076

0.061

12.2

7.56

4.7

DC Resistance max @ 50Hz - Ώ/km

0.116

0.112

0.106

0.103

0.1

0.097

0.094

0.092

0.091

0.09

0.089

0.11

0.103

0.096

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

RFOU Single/Multicore Armoured Cables - Table 2/4 Cable

2x6

2 x 10

2 x 16

3 x 1.5

3 x 2.5

3x4

3x6

3 x 10

3 x 16

3 x 25

3 x 35

3 x 50

3 x 70

3 x95

Stranding mm

7/1.04

7/1.35

7/1.70

7/0.53

7/0.67

7/0.85

7/1.04

7/1.35

7/1.70

19/1.35

19/1.53

19/1.78

19/2.14

37/1.78 1.6

Insulation Thickness mm

1

1

1

1

1

1

1

1

1

1.2

1.2

1.4

1.4

Thickness of Inner Sheath mm

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.2

1.2

1.2

1.4

1.4

Diameter over Inner Sheath (min/max) mm

12.0/14.0

14.0/16.0

16.0/18.0

9.5/11.5

10.5/12.5

11.5/13.5

13.0/15.0

15.0/17.0

17.0/19.0

20.5/23.5

23.0/26.0

27.5/30.5

31.0/35.0

35.5/39.5 0.5

Diameter of Armour/Braid mm

0.3

0.3

0.4

0.2

0.3

0.3

0.3

0.3

0.4

0.3

0.3

0.4

0.5

Thickness of Outer Sheath mm

1.3

1.4

1.5

1.2

1.3

1.3

1.4

1.4

1.5

1.6

1.7

1.9

2

2.2

Overall Diameter (min/max) mm

15.5/17.5

17.5/19.5

20.0/23.0

12.5/14.5

14.0/16.0

15.0/17.0

16.5/18.5

18.5/20.5

21.0./24.0

25.0/28.0

27.5/30.5

32.0/36.0

37.0/41.0

41.0/46.0

Gland Size

A

A

B

O

O

A

A

A

B

C

C

C2

C2

D

Weight kg/km

490

640

910

290

370

460

570

740

1070

1520

1880

2630

3540

4660

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

85 13300

Short Circuit Rating, 1second ampere

840

1400

2240

210

350

560

840

1400

2240

3500

4900

7000

9800

Current Rating at 45°C - ampere

41

57

77

14

20

27

34

47

63

84

100

125

160

195

DC Resistance max @ 20°c - Ώ/km

3.11

1.84

1.16

12.2

7.56

4.7

3.11

1.84

1.16

0.734

0.529

0.391

0.27

0.195

DC Resistance max @ 50Hz - Ώ/km

0.09

0.084

0.08

0.11

0.103

0.096

0.09

0.08

0.079

0.076

0.076

0.076

0.075

0.073

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Datasheet Ref: OFS-NK-PC-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000V Flame Retardant

Offshore Power & Control Cables to NEK606 Specification

RFOU Single/Multicore Armoured Cables - Table 3/4 Cable

3 x 120

3 x 150

3 x 185

4 x 1.5

4 x 2.5

4x4

4x6

4 x 10

4 x 16

4 x 25

4 x 35

4 x 50

4 x 70

4 x 95

Stranding mm

37/2.03

-

-

7/0.53

7/0.67

7/0.85

7/1.04

7/1.35

7/1.70

19/1.35

19/1.53

19/1.78

19/2.14

37/1.78

Insulation Thickness mm

1.6

1.8

2

1

1

1

1

1

1

1.2

1.2

1.4

1.4

1.6

Thickness of Inner Sheath mm

1.4

1.6

1.6

1.1

1.1

1.1

1.1

1.1

1.2

1.2

1.2

1.4

1.4

1.4

Diameter over Inner Sheath (min/max) mm

38.5/43.5

42.5/47.5

49.5/54.5

10.5/12.5

11.5/13.5

12.5/14.5

14.0/16.0

16.5/18.5

18.5/21.5

22.5/25.5

26.0/29.0

30.0/34.0

34.5/38.5

39.0/44.0 0.5

Diameter of Armour/Braid mm

0.6

0.6

0.5

0.3

0.3

0.3

0.3

0.3

0.4

0.3

0.3

0.4

0.5

Thickness of Outer Sheath mm

2.3

2.5

2.7

1.3

1.3

1.4

1.4

1.5

1.6

1.7

1.8

2

2.2

2.4

Overall Diameter (min/max) mm

45.5/50.5

51.0/57.0

59.0/66.0

14.0/16.0

15.0/17.0

16.5/18.5

18.0/20.0

20.0/23.0

23.5/26.5

27.5./30.5

30.0/34.0

35.5/39.5

40.5/45.5

45.5/50.5

Gland Size

D

E

F

O

A

A

A

B

C

C

C2

C2

D

D

Weight kg/km

5740

7450

25900

210

350

560

840

1400

2240

3500

4900

7000

9800

13300

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second ampere

16800

21000

25900

210

350

560

840

1400

2240

3500

4900

7000

9800

13300

Current Rating at 45°C - ampere

225

255

290

14

20

27

34

47

63

84

100

125

160

195

DC Resistance max @ 20°c - Ώ/km

0.154

0.126

0.1

12.2

7.56

4.7

3.11

1.84

1.16

0.734

0.529

0.391

0.27

0.195

DC Resistance max @ 50Hz - Ώ/km

0.072

0.072

0.072

0.11

0.103

0.096

0.09

0.084

0.08

0.079

0.076

0.076

0.075

0.073

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

RFOU Single/Multicore Armoured Cables - Table 4/4 Cable

4x185

5 x 1.5

7 x 1.5

7 x 2.5

12 x 1.5

12 x 2.5

19 x 1.5

19 x 2.5

27 x 1.5

27 x 2.5

37 x 1.5

37 x 2.5

Stranding mm

-

-

7/0.53

7/0.67

7/0.53

7/0.67

7/0.53

7/0.67

7/0.53

7/0.67

7/0.53

7/0.67

Insulation Thickness mm

2

1

1

1

1

1

1

1

1

1

1

1

Thickness of Inner Sheath mm

1.6

1.1

1.1

1.1

1.1

1.2

1.2

1.2

1.2

1.2

1.2

-

Diameter over Inner Sheath (min/max) mm

52.5/57.5

11.5/13.5

12.5/14.5

13.5/15.5

17.0/19.0

18.5/20.5

19.5/22.5

21.5/24.5

23.5/26.5

26.0/29.0

26.5/29.5

29.5/33.5 -

Diameter of Armour/Braid mm

0.6

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Thickness of Outer Sheath mm

2.8

1.3

1.3

1.4

1.5

1.6

1.6

1.7

1.8

1.9

1.9

-

Overall Diameter (min/max) mm

63.0/70.0

15.0/17.0

16.0/18.0

17.5/19.5

20.5/23.5

22.5/25.5

24.0/27.0

26.0/29.0

28.0/32.0

30.5/34.5

31.0./35.0

34.5/38.5

Gland Size

F

A

A

O

B

B

C

C

C

C2

C2

C2

Weight kg/km

25900

210

210

610

720

910

990

1260

1320

1680

1670

2190

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second ampere

25900

210

210

350

210

350

210

350

210

350

210

350

Current Rating at 45°C - ampere

290

12

10

15

9

12

8

11

6.5

9

6

8

0.1

12.2

12.2

7.56

12.2

7.56

12.2

7.56

12.2

7.56

12.2

7.56

DC Resistance max @ 20°c Ώ/km DC Resistance max @ 50Hz Ώ/km Sheath Colour

0.072

0.11

0.11

0.103

0.11

0.103

0.11

0.103

0.11

0.103

0.11

0.103

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Datasheet Ref: OFS-NK-PC-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


Section 5 Offshore Power & Control Cables to NEK 606 Specification

BFOU FIRE RESISTANT

FPAL Verify

Verified No.10049350

ABS

5


BS6883

Offshore Power & Control Cables to NEK 606 Specification

NEK606

600/1000 V Fire Resistant

BFOU Single and Multicore armoured cables:

Applicable Standards

IEEE

NEK 606 / IEC 60092-3 IEC 60092-351 IEC 60331 part 3 (Category A) IEC 60092-359 Stranded class 2 or tinned annealed copper conductors to IEC60228

Application IEC

This range of cables is designed for use in fixed wiring on ships and offshore platforms and drilling rigs, especially used where life may be endangered by smoke and noxious fumes, and where sensitive equipment may be damaged by acid forming gases.

Conductor Identification One core: Black Two cores: Blue – Brown Two cores + earth Blue – Brown – Yellow/green Three cores: Brown - Black – Grey Three cores + earth Brown - Black – Grey – Yellow/green Four cores: Blue - Brown - Black– Grey Four cores + earth Blue - Brown - Black– Grey – Yellow/green Five cores Blue - Brown - Black– Grey - Black Above 5-cores : Black numbers on white base.

Note: picture is for illustration purposes only

New harmonised core colours or project specified colours can be supplied upon special request

Construction

Specifications

(1) Conductor:

Tinned Stranded Annealed Copper Conductor to IEC60228

(2) Fire Protection

Mica Glass Tape

(3) Insulation:

(B) - EPR Complying with IEC60092-351

(4) Bedding:

(F) - Flame Retardant Halogen Free Compound, PETP-tape

(5) Armour:

(O) - Tinned Copper Wire Braid to NVE FEA-M 1238.5, PETP-tape

(6) Outer Sheath:

(U) - SHF2 dual Compound thermo set rubber - IEC60092-359 Type SHF2, Dual rated as being Both halogen free and mud resistant in accordance with NEK606, and meets cold bend and Impact test (-20C) cross sectional area C22.2

Datasheet Ref: OFS-NK-PC-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com

FPAL Verify

Verified

No.10049350

ABS


600/1000 V Fire Resistant

Offshore Power & Control Cables to NEK 606 Specification

BFOU Single/Multicore Armoured Cables - Table 1/4 Cable

1 x16

1 x 25

1 x 35

1 x 50

1 x 70

1 x 95

1 x 120

1 x 150

1 x 185

1 x 240

1 x 300

2 x 1.5

2 x2.5

2x4

Stranding mm

7/1.70

19/1.35

19/1.53

19/1.78

19/2.14

37/1.78

37/2.03

37/2.25

37/2.52

61/2.25

61/2.52

7/0.53

7/0.67

7/0.85

Insulation Thickness mm

1

1.2

1.2

1.4

1.4

1.6

1.6

1.8

2

2.2

2.4

1

1

1

Thickness of Inner Sheath mm

1.1

1.1

-

1.1

1.1

1.1

1.2

1.2

1.2

1.2

1.2

1.1

1.1

1.1

Diameter over Inner Sheath (min/max) mm

9.5/11.5

11.0/13.0

12.5/14.5

14.5/16.5

16.0/18.0

18.0/20.0

19.5/22.5

22.0/25.0

24.0/27.0

27.0/30.0

29.0/33.0

9.5/11.5

10.5/12.5

11.5/13.5

Diameter of Armour/Braid mm

0.2

0.3

-

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.3

0.3

Thickness of Outer Sheath mm

1.2

1.3

-

1.4

1.4

1.5

1.6

1.7

1.7

1.8

1.9

1.2

1.3

1.3

Overall Diameter (min/max) mm

12.5/14.5

14.0/16.0

16.0/18.0

18.0/20.0

19.5/22.5

22.0/25.0

24.0/27.0

26.0/29.0

28.5/31.5

31.0/35.0

34.5/38.5

12.5/14.5

13.5/15.5

15.0/17.0

Gland Size

O

O

A

A

B

B

C

C

C

C2

C2

O

O

A

Weight kg/km

360

480

650

830

1070

1380

1700

2030

2470

3130

3820

280

320

420

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second ampere

2240

3500

4900

7000

9800

13300

16800

21000

25900

33600

42000

210

350

560

90

120

145

180

225

275

320

365

415

490

560

17

24

32

1.16

0.734

0.529

0.391

0.27

0.195

0.154

0.126

0.1

0.0762

0.0607

12.2

7.56

4.7

DC Resistance max @ 50Hz - Ώ/km

0.12

0.113

0.107

0.104

0.101

0.098

0.094

0.094

0.091

0.091

0.089

0.015

0.107

0.1

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Current Rating at

45°C - ampere

DC Resistance max @ 20°c - Ώ/km

BFOU Single/Multicore Armoured Cables - Table 2/4 Cable

2x6

2 x 10

2 x 16

3 x 1.5

3 x 2.5

3x4

3x6

3 x 10

3 x 16

3 x 25

3 x 35

3 x 50

3 x 70

3 x95

Stranding mm

7/1.04

7/1.35

7/1.70

7/0.53

7/0.67

7/0.85

7/1.04

7/1.35

7/1.70

19/1.35

19/1.53

19/1.78

19/2.14

37/1.78 1.6

Insulation Thickness mm

1

1

1

1

1

1

1

1

1

1.2

1.2

1.4

1.4

Thickness of Inner Sheath mm

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.2

1.2

1.2

1.4

1.4

Diameter over Inner Sheath (min/max) mm

12.5/14.5

14.5/16.5

16.5/18.5

10.0/12.0

11.0/13.0

12.5/14.5

13.5/15.5

15.5/17.5

18.0/20.0

21.0/24.0

24.0/27.0

28.0/31.0

32.5/36.5

36.0/40.0 0.6

Diameter of Armour/Braid mm

0.3

0.3

0.5

0.3

0.3

0.3

0.3

0.3

0.4

0.3

0.3

0.4

0.5

Thickness of Outer Sheath mm

1.4

1.4

1.5

1.3

1.3

1.3

1.4

1.5

1.5

1.7

1.8

1.9

2

2.2

Overall Diameter (min/max) mm

16.5/18.5

18.5/20.5

21.0/24.0

13.5/15.5

14.5/16.5

16.0/18.0

17.5/19.5

19.5/21.5

22.0./25.0

25.5/28.5

28.0/32.0

32.5/36.5

38.0/43.0

42.0/47.0

Gland Size

A

A

B

O

A

A

A

B

B

C

C

C2

D

D

Weight kg/km

510

680

960

310

400

500

590

780

1130

1510

1930

2640

3630

4720

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second ampere

840

1400

2240

210

350

560

840

1400

2240

3500

4900

7000

9800

13300

41

57

77

14

20

27

34

47

63

84

100

125

160

195

DC Resistance max @ 20°c - Ώ/km

3.11

1.84

1.16

12.2

7.56

4.7

3.11

1.84

1.16

0.734

0.529

0.391

0.27

0.195

DC Resistance max @ 90°c - Ώ/km

0.094

0.088

0.082

0.015

0.107

0.1

0.094

0.088

0.082

0.081

0.078

0.078

0.077

0.075

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Current Rating at

45°C - ampere

Datasheet Ref: OFS-NK-PC-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000 V Fire Resistant

Offshore Power & Control Cables to NEK 606 Specification

BFOU Single/Multicore Armoured Cables - Table 3/4 Cable

3 x 120

3 x 150

3 x 185

4 x 1.5

4 x 2.5

4x4

4x6

4 x 10

4 x 16

4 x 25

4 x 35

4 x 50

4 x 70

4 x 95

Stranding mm

37/2.03

-

-

7/0.53

7/0.67

7/0.85

7/1.04

7/1.35

7/1.70

19/1.35

19/1.53

19/1.78

19/2.14

37/1.78

Insulation Thickness mm

1.6

1.8

2

1

1

1

1

1

1

1.2

1.2

1.4

1.4

1.6

Thickness of Inner Sheath mm

1.4

1.6

1.6

1.1

1.1

1.1

1.1

1.1

1.2

1.2

1.2

1.4

1.4

1.4

Diameter over Inner Sheath (min/max) mm

38.5/43.5

42.5/47.5

49.5/54.5

10.5/12.5

11.5/13.5

12.5/14.5

14.0/16.0

16.5/18.5

18.5/21.5

22.5/25.5

26.0/29.0

30.0/34.0

34.5/38.5

39.0/44.0 0.5

Diameter of Armour/Braid mm

0.6

0.6

0.5

0.3

0.3

0.3

0.3

0.3

0.4

0.3

0.3

0.4

0.5

Thickness of Outer Sheath mm

2.3

2.5

2.7

1.3

1.3

1.4

1.4

1.5

1.6

1.7

1.8

2

2.2

2.4

Overall Diameter (min/max) mm

45.5/50.5

51.0/57.0

59.0/66.0

14.0/16.0

15.0/17.0

16.5/18.5

18.0/20.0

20.0/23.0

23.5/26.5

27.5./30.5

30.0/34.0

35.5/39.5

40.5/45.5

45.5/50.5

Gland Size

D

E

F

O

A

A

A

B

C

C

C2

C2

D

D

Weight kg/km

5740

7450

25900

210

350

560

840

1400

2240

3500

4900

7000

9800

13300

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

85 13300

Short Circuit Rating, 1second ampere

16800

21000

25900

210

350

560

840

1400

2240

3500

4900

7000

9800

Current Rating at 45°C - ampere

225

255

290

14

20

27

34

47

63

84

100

125

160

195

DC Resistance max @ 20°c - Ώ/km

0.154

0.126

0.1

12.2

7.56

4.7

3.11

1.84

1.16

0.734

0.529

0.391

0.27

0.195

DC Resistance max @ 50Hz - Ώ/km

0.072

0.072

0.072

0.11

0.103

0.096

0.09

0.084

0.08

0.079

0.076

0.076

0.075

0.073

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

BFOU Single/Multicore Armoured Cables - Table 4/4 Cable

4x120

4x185

5 x 1.5

7 x 1.5

7 x 2.5

12 x 1.5

12 x 2.5

19 x 1.5

19 x 2.5

27 x 1.5

27 x 2.5

37 x 1.5

37 x 2.5 7/0.67

Stranding mm

37/2.03

-

-

7/0.53

7/0.67

7/0.53

7/0.67

7/0.53

7/0.67

7/0.53

7/0.67

7/0.53

Insulation Thickness mm

1.6

2.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

Thickness of Inner Sheath mm

1.6

-

1.1

1.1

1.1

1.2

1.2

1.2

1.2

1.2

1.4

1.4

1.4

Diameter over Inner Sheath (min/max) mm

43.5/48.5

55.0/61.0

12.0/14.0

13.5/15.5

14.5/16.5

18.0/20.0

19.5/22.5

21.0/24.0

23.0/26.0

25.5/28.5

28.0/31.0

28.5/32.5

31.5/35.5

Diameter of Armour/Braid mm

0.6

-

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.4

Thickness of Outer Sheath mm

2.5

-

1.4

1.4

1.4

1.6

1.6

1.7

1.8

1.9

2.0

2.0

2.2

Overall Diameter (min/max) mm

50.5/56.5

65.0/72.0

16.0/18.0

17.0/19.0

18.5/20.5

21.5/24.5

23.5/26.5

25.5/28.5

27.5/30.5

29.5/33.5

32.5/36.5

33.5./37.5

37.0/41.0

Gland Size

E

F

A

A

A

B

C

C

C

C2

C2

C2

C2

Weight kg/km

7180

12000

460

520

650

780

980

1080

1350

1440

1810

1840

2370

Bend Radius - xOD

8

8

8

8

8

8

8

8

8

8

8

8

8

Conductor Temperature - °C

85

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second ampere

16800

25900

210

210

350

210

350

210

350

210

350

210

350

Current Rating at 45°C - ampere

225

290

12

10

15

9

12

8

11

6.5

9

6

8

DC Resistance max @ 20°c - Ώ/km

0.1540

0.1000

12.2000

12.2000

7.5600

12.2000

7.56

12.2000

7.5600

12.2000

7.5600

12.2000

7.5600

DC Resistance max @ 90°c - Ώ/km

0.073

0.073

0.015

0.015

0.107

0.015

0.107

0.015

0.107

0.015

0.107

0.015

0.107

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Datasheet Ref: OFS-NK-PC-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


Section 6 Medium Voltage Power Cables to NEK 606 Specification

RFOU FLAME RETARDANT

FPAL Verify

Verified No.10049350

ABS

6


BS6883

Medium Voltage Power Cables to NEK606 Specification NEK606

3.6/6kV Flame Retardant RFOU Power Cables, Single Core, Armoured Cables:

Applicable Standards

IEC

IEEE

NEK 606 IEC 60092-354 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228

Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009

Conductor Identification One core: Black New harmonised core colours or project specified colours can be supplied upon special request. Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Conductor Screen:

Semi-conductive tape or extruded semi-conductive compound.

(3) Insulation:

EP-Rubber

(4) Insulation Screen:

Semi-conductive tape or extruded semi-conductive compound.

(5) Metallic Screen:

Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)

(6) Bedding:

Flame retardant halogen free compound. PET Tape

(7) Armour:

Tinned copper wire braid. PET Tape

(8) Outer Sheath

SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour

Datasheet Ref: OFS-NK-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


3.6/6kV Flame Retardant

Medium Voltage Power Cables to NEK606 Specification

RFOU Single Core Armoured Cables Conductor No. of Cores

Nominal Area

Strand

Overall diameter Dia.

Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering

Conductor Resistance (at 20ºC) (Max.)

Insulation Resistance (at 20ºC) (Min.)

Test Voltage

Current Carrying Capacity (Max.) (at 45ºC)

Cable Weight

kg/km

No.

mm²

NO./

mm

mm

mm

mm

mm

mm

mm

mm

±mm

Ω / km

MΏ-km

V/5min.

A

1

25

7/

2.14

6.42

2.5

1.0

18.0

0.3

1.6

23.3

1.4

0.734

920

12.5

121

990

1

35

7/

2.52

7.56

2.5

1.0

19.2

0.3

1.6

24.5

1.5

0.529

810

12.5

149

1,140

1

50

19 /

1.78

8.90

2.5

1.0

20.5

0.3

1.7

26.0

1.5

0.391

710

12.5

186

1,330

1

70

19 /

2.14

10.70

2.5

1.0

22.3

0.3

1.8

28.0

1.6

0.270

610

12.5

230

1,620

1

95

19 /

2.52

12.60

2.5

1.0

24.2

0.3

1.8

29.9

1.7

0.195

530

12.5

278

1,960

1

120

37 /

2.03

14.21

2.5

1.0

25.8

0.3

1.9

31.7

1.8

0.154

480

12.5

322

2,280

1

150

37 /

2.25

15.75

2.5

1.2

27.8

0.3

2.0

33.9

1.9

0.126

440

12.5

370

2,660

1

185

37 /

2.52

17.64

2.5

1.2

29.6

0.3

2.0

35.7

1.9

0.100

400

12.5

422

3,090

1

240

61 /

2.25

20.25

2.6

1.2

32.5

0.4

2.2

39.5

2.1

0.0762

360

12.5

496

3,930

1

300

61 /

2.52

22.68

2.8

1.2

35.3

0.4

2.3

42.5

2.2

0.0607

350

12.5

571

4,690

0

Datasheet Ref: OFS-NK-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 NEK606

Medium Voltage Power Cables to NEK606 Specification

RFOU Power Cables, Multi Core, Armoured Cables:

Applicable Standards IEEE

NEK 606 IEC 60092-354 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228

Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009

IEC

3.6/6kV Flame Retardant

Conductor Identification The individual cores shall be identified by the coloured semi-conducting tape or coloured ribbon tape run longitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows: 3 Cores: Off-White (grey), Black and Red New harmonised core colours or project specified colours can be supplied upon special request.

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Conductor Screen:

Semi-conductive tape or extruded semi-conductive compound.

(3) Insulation:

EP-Rubber

(4) Insulation Screen:

Semi-conductive tape or extruded semi-conductive compound.

(5) Metallic Screen:

Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)

(6) Bedding:

Flame retardant halogen free compound. PET Tape

(7) Armour:

Tinned copper wire braid. PET Tape

(8) Outer Sheath

SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour

Datasheet Ref: OFS-NK-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


3.6/6kV Flame Retardant

Medium Voltage Power Cables to NEK606 Specification

RFOU Multi Core Armoured Cables Conductor No. of Cores

Nominal Area

Strand

Overall diameter Dia.

Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering

Conductor Resistance (at 20ºC) (Max.)

Insulation Resistance (at 20ºC) (Min.)

Test Voltage

Current Carrying Capacity (Max.) (at 45ºC)

Cable Weight

No.

mm²

NO./

mm

mm

mm

mm

mm

mm

mm

mm

±mm

Ω / km

MΏ-km

V/5min.

A

kg/km

3

25

7/

2.14

6.42

2.5

1.2

36.8

0.4

2.4

44.2

2.3

0.734

920

12.5

85

3,300

3

35

7/

2.52

7.56

2.5

1.4

39.8

0.4

2.5

47.4

2.4

0.529

810

12.5

105

3,890

3

50

19 /

1.78

8.90

2.5

1.4

42.6

0.4

2.6

50.4

2.5

0.391

710

12.5

130

4,540

3

70

19 /

2.14

10.70

2.5

1.4

46.4

0.4

2.7

54.4

2.7

0.270

610

12.5

161

5,530

3

95

19 /

2.52

12.60

2.5

1.6

50.9

0.4

2.9

59.3

2.9

0.195

530

12.5

195

6,810

3

120

37 /

2.03

14.21

2.5

1.6

54.4

0.4

3.1

63.2

3.0

0.154

480

12.5

225

7,960

3

150

37 /

2.25

15.75

2.5

1.6

57.8

0.4

3.2

66.8

3.2

0.126

440

12.5

258

9,130

3

185

37 /

2.52

17.64

2.5

1.6

61.7

0.4

3.4

71.1

3.3

0.100

400

12.5

295

10,700

0

Datasheet Ref: OFS-NK-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883

Medium Voltage Power Cables to NEK606 Specification NEK606

6/10kV Flame Retardant RFOU Power Cables, Single Core, Armoured Cables:

Applicable Standards

IEC

IEEE

NEK 606 IEC 60092-354 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228

Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009

Conductor Identification One core: Black New harmonised core colours or project specified colours can be supplied upon special request. Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Conductor Screen:

Semi-conductive tape or extruded semi-conductive compound.

(3) Insulation:

EP-Rubber

(4) Insulation Screen:

Semi-conductive tape or extruded semi-conductive compound.

(5) Metallic Screen:

Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)

(6) Bedding:

Flame retardant halogen free compound. PET Tape

(7) Armour:

Tinned copper wire braid. PET Tape

(8) Outer Sheath

SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour

Datasheet Ref: OFS-NK-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


6/10kV Flame Retardant

Medium Voltage Power Cables to NEK606 Specification

RFOU Single Core Armoured Cables Conductor No. of Cores

Nominal Area

Strand

Overall diameter Dia.

Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering

Conductor Resistance (at 20ºC) (Max.)

Insulation Resistance (at 20ºC) (Min.)

Test Voltage

Current Carrying Capacity (Max.) (at 45ºC)

Cable Weight

No.

mm²

NO./

mm

mm

mm

mm

mm

mm

mm

mm

±mm

Ω / km

MΏ-km

V/5min.

A

kg/km

1

25

7/

2.14

6.42

3.4

1.0

19.8

0.3

1.7

25.3

1.5

0.734

1,150

21

121

1,120

1

35

7/

2.52

7.56

3.4

1.0

21.0

0.3

1.7

26.5

1.6

0.529

1,020

21

149

1,270

1

50

19 /

1.78

8.90

3.4

1.0

22.3

0.3

1.8

28.0

1.6

0.391

900

21

186

1,470

1

70

19 /

2.14

10.70

3.4

1.0

24.1

0.3

1.8

29.8

1.7

0.270

780

21

230

1,760

1

95

19 /

2.52

12.60

3.4

1.0

26.0

0.3

1.9

31.9

1.8

0.195

690

21

278

2,110

1

120

37 /

2.03

14.21

3.4

1.2

28.0

0.3

2.0

34.1

1.9

0.154

620

21

322

2,480

1

150

37 /

2.25

15.75

3.4

1.2

29.6

0.3

2.0

35.7

1.9

0.126

570

21

370

2,820

1

185

37 /

2.52

17.64

3.4

1.2

31.4

0.4

2.1

38.2

2.0

0.100

520

21

422

3,390

1

240

61 /

2.25

20.25

3.4

1.2

34.1

0.4

2.2

41.1

2.1

0.0762

460

21

496

4,090

1

300

61 /

2.52

22.68

3.4

1.2

36.8

0.4

2.4

44.2

2.3

0.0607

420

21

571

4,900

0

Datasheet Ref: OFS-NK-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 NEK606

Medium Voltage Power Cables to NEK606 Specification

RFOU Power Cables, Multi Core, Armoured Cables:

Applicable Standards IEEE

NEK 606 IEC 60092-354 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228

Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009

IEC

6/10kV Flame Retardant

Conductor Identification The individual cores shall be identified by the coloured semi-conducting tape or coloured ribbon tape run longitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows: 3 Cores: Off-White (grey), Black and Red New harmonised core colours or project specified colours can be supplied upon special request.

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Conductor Screen:

Semi-conductive tape or extruded semi-conductive compound.

(3) Insulation:

EP-Rubber

(4) Insulation Screen:

Semi-conductive tape or extruded semi-conductive compound.

(5) Metallic Screen:

Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)

(6) Bedding:

Flame retardant halogen free compound. PET Tape

(7) Armour:

Tinned copper wire braid. PET Tape

(8) Outer Sheath

SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour

Datasheet Ref: OFS-NK-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


6/10kV Flame Retardant

Medium Voltage Power Cables to NEK606 Specification

RFOU Multi Core Armoured Cables Conductor No. of Cores

Nominal Area

Strand

Overall diameter Dia.

Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering

Conductor Resistance (at 20ºC) (Max.)

Insulation Resistance (at 20ºC) (Min.)

Test Voltage

Current Carrying Capacity (Max.) (at 45ºC)

Cable Weight

No.

mm²

NO./

mm

mm

mm

mm

mm

mm

mm

mm

±mm

Ω / km

MΏ-km

V/5min.

A

kg/km

3

25

7/

2.14

6.42

3.4

1.4

41.0

0.4

2.5

48.6

2.4

0.734

1,150

21

85

3,840

3

35

7/

2.52

7.56

3.4

1.4

43.6

0.4

2.6

51.4

2.6

0.529

1,020

21

105

4,400

3

50

19 /

1.78

8.90

3.4

1.4

46.4

0.4

2.7

54.4

2.7

0.391

900

21

130

5,080

3

70

19 /

2.14

10.70

3.4

1.6

50.7

0.4

2.9

59.1

2.9

0.270

780

21

161

6,210

3

95

19 /

2.52

12.60

3.4

1.6

54.8

0.4

3.1

63.6

3.0

0.195

690

21

195

7,480

3

120

37 /

2.03

14.21

3.4

1.6

58.3

0.4

3.2

67.3

3.2

0.154

620

21

225

8,640

3

150

37 /

2.25

15.75

3.4

1.6

61.7

0.4

3.4

71.1

3.3

0.126

570

21

258

9,880

3

185

37 /

2.52

17.64

3.4

1.8

66.0

0.4

3.5

75.6

3.5

0.100

520

21

295

11,530

3

240

61 /

2.25

20.25

3.4

1.8

71.8

0.4

3.8

82.0

3.8

0.0762

460

21

347

14,020

0

Datasheet Ref: OFS-NK-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883

Medium Voltage Power Cables to NEK606 Specification NEK606

8.7/15kV Flame Retardant RFOU Power Cables, Single Core, Armoured Cables:

Applicable Standards

IEC

IEEE

NEK 606 IEC 60092-354 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228

Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009

Conductor Identification One core: Black New harmonised core colours or project specified colours can be supplied upon special request. Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Conductor Screen:

Semi-conductive tape or extruded semi-conductive compound.

(3) Insulation:

EP-Rubber

(4) Insulation Screen:

Semi-conductive tape or extruded semi-conductive compound.

(5) Metallic Screen:

Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)

(6) Bedding:

Flame retardant halogen free compound. PET Tape

(7) Armour:

Tinned copper wire braid. PET Tape

(8) Outer Sheath

SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour

Datasheet Ref: OFS-NK-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


8.7/15kV Flame Retardant

Medium Voltage Power Cables to NEK606 Specification

RFOU Single Core Armoured Cables Conductor No. of Cores

Nominal Area

Strand

Overall diameter Dia.

Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering

Conductor Resistance (at 20ºC) (Max.)

Insulation Resistance (at 20ºC) (Min.)

Test Voltage

Current Carrying Capacity (Max.) (at 45ºC)

Cable Weight

No.

mm²

NO./

mm

mm

mm

mm

mm

mm

mm

mm

±mm

Ω / km

MΏ-km

V/5min.

A

kg/km

1

25

7/

2.14

6.42

4.5

1.0

22.0

0.3

1.7

27.5

1.6

0.734

1,400

30.5

121

1,270

1

35

7/

2.52

7.56

4.5

1.0

23.2

0.3

1.8

28.9

1.7

0.529

1,250

30.5

149

1,440

1

50

19 /

1.78

8.90

4.5

1.0

24.5

0.3

1.8

30.2

1.7

0.391

1,110

30.5

186

1,630

1

70

19 /

2.14

10.70

4.5

1.0

26.3

0.3

1.9

32.2

1.8

0.270

970

30.5

230

1,950

1

95

19 /

2.52

12.60

4.5

1.2

28.6

0.3

2.0

34.7

1.9

0.195

860

30.5

278

2,350

1

120

37 /

2.03

14.21

4.5

1.2

30.2

0.4

2.1

37.0

2.0

0.154

780

30.5

322

2,800

1

150

37 /

2.25

15.75

4.5

1.2

31.8

0.4

2.2

38.8

2.1

0.126

720

30.5

370

3,170

1

185

37 /

2.52

17.64

4.5

1.2

33.6

0.4

2.2

40.6

2.1

0.100

660

30.5

422

3,620

1

240

61 /

2.25

20.25

4.5

1.2

36.6

0.4

2.3

43.8

2.3

0.0762

590

30.5

496

4,400

1

300

61 /

2.52

22.68

4.5

1.4

39.4

0.4

2.5

47.0

2.4

0.0607

530

30.5

571

5,190

0

Datasheet Ref: OFS-NK-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 NEK606

Medium Voltage Power Cables to NEK606 Specification

RFOU Power Cables, Multi Core, Armoured Cables:

Applicable Standards IEEE

NEK 606 IEC 60092-354 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228

Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009

IEC

8.7/15kV Flame Retardant

Conductor Identification The individual cores shall be identified by the coloured semi-conducting tape or coloured ribbon tape run longitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows: 3 Cores: Off-White (grey), Black and Red New harmonised core colours or project specified colours can be supplied upon special request.

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Conductor Screen:

Semi-conductive tape or extruded semi-conductive compound.

(3) Insulation:

EP-Rubber

(4) Insulation Screen:

Semi-conductive tape or extruded semi-conductive compound.

(5) Metallic Screen:

Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)

(6) Bedding:

Flame retardant halogen free compound. PET Tape

(7) Armour:

Tinned copper wire braid. PET Tape

(8) Outer Sheath

SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour

Datasheet Ref: OFS-NK-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


8.7/15kV Flame Retardant

Medium Voltage Power Cables to NEK606 Specification

RFOU Multi Core Armoured Cables Conductor No. of Cores

Nominal Area

Strand

Overall diameter Dia.

Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering

Conductor Resistance (at 20ºC) (Max.)

Insulation Resistance (at 20ºC) (Min.)

Test Voltage

Current Carrying Capacity (Max.) (at 45ºC)

Cable Weight

No.

mm²

NO./

mm

mm

mm

mm

mm

mm

mm

mm

±mm

Ω / km

MΏ-km

V/5min.

A

kg/km

3

25

7/

2.14

6.42

4.5

1.4

45.8

0.4

2.7

53.8

2.7

0.734

1,400

30.5

85

4,520

3

35

7/

2.52

7.56

4.5

1.6

48.8

0.4

2.8

57.0

2.8

0.529

1,250

30.5

105

5,180

3

50

19 /

1.78

8.90

4.5

1.6

51.6

0.4

2.9

60.0

2.9

0.391

1,110

30.5

130

5,890

3

70

19 /

2.14

10.70

4.5

1.6

55.5

0.4

3.1

64.3

3.1

0.270

970

30.5

161

7,030

3

95

19 /

2.52

12.60

4.5

1.6

59.5

0.4

3.3

68.7

3.2

0.195

860

30.5

195

8,330

3

120

37 /

2.03

14.21

4.5

1.6

63.0

0.4

3.4

72.4

3.4

0.154

780

30.5

225

9,530

3

150

37 /

2.25

15.75

4.5

1.8

66.8

0.4

3.6

76.6

3.6

0.126

720

30.5

258

10,890

3

185

37 /

2.52

17.64

4.5

1.8

70.7

0.4

3.7

80.7

3.7

0.100

660

30.5

295

12,520

0

Datasheet Ref: OFS-NK-PC-MV-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


Section 6 Medium Voltage Power Cables to NEK 606 Specification

BFOU FIRE RESISTANT

FPAL Verify

Verified No.10049350

ABS

6


BS6883

Medium Voltage Power Cables to NEK 606 Specification

BFOU - Power/Control Cables – Single Core, Medium Power, armoured cables

NEK606

3.6/6 kV Fire Resistant

Applicable Standards

IEC

IEEE

NEK 606 IEC 60092-354 IEC 60331 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228

Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009

Conductor Identification One core: Black New harmonised core colours or project specified colours can be supplied upon special request.

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Fire Protection:

Mica Glass Tape

(3) Insulation:

EP-Rubber

(4) Insulation Screen:

Semi-conductive tape or extruded semi-conductive compound.

(5) Metallic Screen:

Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)

(6) Bedding:

Flame retardant halogen free compound. PET Tape

(7) Amour:

Tinned copper wire braid. PET Tape

(8) Outer Sheath:

SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour

Datasheet Ref: OFS-NK-PC-MV-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com

FPAL Verify

Verified

No.10049350

ABS


3.6/6 kV Fire Resistant

Medium Voltage Power Cables to NEK 606 Specification

BFOU Single Core Armoured Cables Conductor No. of Cores

Nominal Area

Strand

Overall diameter Dia.

Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering

Conductor Resistance (at 20ºC) (Max.)

Insulation Resistance (at 20ºC) (Min.)

Test Voltage

Current Carrying Capacity (Max.) (at 45ºC)

Cable Weight

No.

mm²

NO./

mm

mm

mm

mm

mm

mm

mm

mm

±mm

Ω / km

MΏ-km

V/5min.

A

kg/km

1

25

7/

2.14

6.42

2.5

1.0

20.3

0.3

1.7

26.1

1.5

0.734

920

12.5

114

1,190

1

35

7/

2.52

7.56

2.5

1.0

21.4

0.3

1.7

27.2

1.6

0.529

810

12.5

141

1,360

1

50

19 /

1.78

8.90

2.5

1.0

22.7

0.3

1.8

28.7

1.6

0.391

710

12.5

176

1,590

1

70

19 /

2.14

10.70

2.5

1.0

24.5

0.3

1.8

30.5

1.7

0.270

610

12.5

218

1,920

1

95

19 /

2.52

12.60

2.5

1.0

26.4

0.3

1.9

32.6

1.8

0.195

530

12.5

264

2,330

1

120

37 /

2.03

14.21

2.5

1.2

28.4

0.3

2.0

34.8

1.9

0.154

480

12.5

305

2,760

1

150

37 /

2.25

15.75

2.5

1.2

30.0

0.4

2.1

37.2

2.0

0.126

440

12.5

350

3,280

1

185

37 /

2.52

17.64

2.5

1.2

31.9

0.4

2.2

39.3

2.1

0.100

400

12.5

400

3,830

1

240

61 /

2.25

20.25

2.6

1.2

34.7

0.4

2.3

42.3

2.2

0.0762

360

12.5

470

4,690

1

300

61 /

2.52

22.68

2.8

1.4

38.2

0.4

2.4

46.1

2.3

0.0607

350

12.5

541

5,710

0

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

Datasheet Ref: OFS-NK-PC-MV-FS www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883

Medium Voltage Power Cables to NEK 606 Specification

BFOU - Power/Control Cables – Multi Core, Medium Power, armoured cables

NEK606

3.6/6 kV Fire Resistant

Applicable Standards

IEC

IEEE

NEK 606 IEC 60092-354 IEC 60331 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228

Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009

Conductor Identification The individual cores shall be identified by the coloured semiconducting tape or coloured ribbon tape run longitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows: 3 Cores: Off-White (grey), Black and Red Note: picture is for illustration purposes only

New harmonised core colours or project specified colours can be supplied upon special request.

Construction

Specifications

(1) Conductor:

Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Fire Protection:

Mica Glass Tape

(3) Insulation:

EP-Rubber

(4) Insulation Screen:

Semi-conductive tape or extruded semi-conductive compound.

(5) Metallic Screen:

Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)

(6) Bedding:

Flame retardant halogen free compound. PET Tape

(7) Amour:

Tinned copper wire braid. PET Tape

(8) Outer Sheath:

SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour

Datasheet Ref: OFS-NK-PC-MV-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


3.6/6 kV Fire Resistant

Medium Voltage Power Cables to NEK 606 Specification

BFOU Multi Core Armoured Cables Conductor No. of Cores

Nominal Area

Strand

Overall diameter Dia.

Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering

Conductor Resistance (at 20ºC) (Max.)

Insulation Resistance (at 20ºC) (Min.)

Test Voltage

Current Carrying Capacity (Max.) (at 45ºC)

Cable Weight

No.

mm²

NO./

mm

mm

mm

mm

mm

mm

mm

mm

±mm

Ω / km

MΏ-km

V/5min.

A

kg/km

3

25

7/

2.14

6.42

2.5

1.4

41.9

0.4

2.6

50.2

2.5

0.734

920

12.5

80

4,110

3

35

7/

2.52

7.56

2.5

1.4

44.3

0.4

2.7

52.8

2.6

0.529

810

12.5

99

4,720

3

50

19 /

1.78

8.90

2.5

1.4

47.1

0.4

2.8

55.9

2.7

0.391

710

12.5

123

5,500

3

70

19 /

2.14

10.70

2.5

1.6

51.3

0.4

2.9

60.3

2.9

0.270

610

12.5

152

6,730

3

95

19 /

2.52

12.60

2.5

1.6

55.4

0.4

3.1

64.8

3.1

0.195

530

12.5

185

8,170

3

120

37 /

2.03

14.21

2.5

1.6

58.9

0.4

3.2

68.6

3.2

0.154

480

12.5

213

9,510

3

150

37 /

2.25

15.75

2.5

1.6

62.3

0.4

3.4

72.4

3.4

0.126

440

12.5

245

10,930

3

185

37 /

2.52

17.64

2.5

1.8

66.8

0.4

3.6

77.4

3.6

0.100

400

12.5

280

12,910

3

240

61 /

2.25

20.25

2.6

1.8

73.4

0.4

3.8

84.4

3.9

0.0762

360

12.5

329

16,010

3

300

61 /

2.52

22.68

2.8

1.8

79.4

0.4

4.1

91.1

4.1

0.0607

350

12.5

379

19,190

0

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

Datasheet Ref: OFS-NK-PC-MV-FS www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883

Medium Voltage Power Cables to NEK 606 Specification

BFOU - Power/Control Cables – Single Core, Medium Power, armoured cables

NEK606

6/10 kV Fire Resistant

Applicable Standards

IEC

IEEE

NEK 606 IEC 60092-354 IEC 60331 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228

Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009

Conductor Identification One core: Black New harmonised core colours or project specified colours can be supplied upon special request.

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Fire Protection:

Mica Glass Tape

(3) Insulation:

EP-Rubber

(4) Insulation Screen:

Semi-conductive tape or extruded semi-conductive compound.

(5) Metallic Screen:

Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)

(6) Bedding:

Flame retardant halogen free compound. PET Tape

(7) Amour:

Tinned copper wire braid. PET Tape

(8) Outer Sheath:

SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour

Datasheet Ref: OFS-NK-PC-MV-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


6/10 kV Fire Resistant

Medium Voltage Power Cables to NEK 606 Specification

BFOU Single Core Armoured Cables Conductor No. of Cores

Nominal Area

Strand

Overall diameter Dia.

Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering

Conductor Resistance (at 20ºC) (Max.)

Insulation Resistance (at 20ºC) (Min.)

Test Voltage

Current Carrying Capacity (Max.) (at 45ºC)

Cable Weight

No.

mm²

NO./

mm

mm

mm

mm

mm

mm

mm

mm

±mm

Ω / km

MΏ-km

V/5min.

A

kg/km

1

25

7/

2.14

6.42

3.4

1.0

22.6

0.3

1.8

28.6

1.6

0.734

1,150

21.5

114

1,360

1

35

7/

2.52

7.56

3.4

1.0

23.7

0.3

1.8

29.7

1.7

0.529

1,020

21.5

141

1,540

1

50

19 /

1.78

8.90

3.4

1.0

25.1

0.3

1.9

31.3

1.8

0.391

900

21.5

176

1,770

1

70

19 /

2.14

10.70

3.4

1.0

26.9

0.3

1.9

33.1

1.8

0.270

780

21.5

218

2,120

1

95

19 /

2.52

12.60

3.4

1.2

29.2

0.3

2.0

35.7

1.9

0.195

690

21.5

264

2,590

1

120

37 /

2.03

14.21

3.4

1.2

30.8

0.4

2.1

38.0

2.0

0.154

620

21.5

305

3,090

1

150

37 /

2.25

15.75

3.4

1.2

32.3

0.4

2.2

39.7

2.1

0.126

570

21.5

350

3,510

1

185

37 /

2.52

17.64

3.4

1.2

34.2

0.4

2.3

41.8

2.2

0.100

520

21.5

400

4,070

1

240

61 /

2.25

20.25

3.4

1.2

37.1

0.4

2.4

44.9

2.3

0.0762

460

21.5

470

4,980

1

300

61 /

2.52

22.68

3.4

1.4

39.9

0.4

2.5

48.0

2.4

0.0607

420

21.5

541

5,920

0

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

Datasheet Ref: OFS-NK-PC-MV-FS www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883

Medium Voltage Power Cables to NEK 606 Specification

BFOU - Power/Control Cables – Multi Core, Medium Power, armoured cables

NEK606

6/10 kV Fire Resistant

Applicable Standards

IEC

IEEE

NEK 606 IEC 60092-354 IEC 60331 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228

Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009

Conductor Identification The individual cores shall be identified by the coloured semiconducting tape or coloured ribbon tape run longitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows: 3 Cores: Off-White (grey), Black and Red Note: picture is for illustration purposes only

New harmonised core colours or project specified colours can be supplied upon special request.

Construction

Specifications

(1) Conductor:

Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Fire Protection:

Mica Glass Tape

(3) Insulation:

EP-Rubber

(4) Insulation Screen:

Semi-conductive tape or extruded semi-conductive compound.

(5) Metallic Screen:

Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)

(6) Bedding:

Flame retardant halogen free compound. PET Tape

(7) Amour:

Tinned copper wire braid. PET Tape

(8) Outer Sheath:

SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour

Datasheet Ref: OFS-NK-PC-MV-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


6/10 kV Fire Resistant

Medium Voltage Power Cables to NEK 606 Specification

BFOU Multi Core Armoured Cables Conductor No. of Cores

Nominal Area

Strand

Overall diameter Dia.

Thickness Thickness Nominal dia. Dia. Of wire Thickness of of inner Inner for armour of sheath Nominal Tolerance Insulation covering covering

Conductor Resistance (at 20ºC) (Max.)

Insulation Resistance (at 20ºC) (Min.)

Test Voltage

Current Carrying Capacity (Max.) (at 45ºC)

Cable Weight

No.

mm²

NO./

mm

mm

mm

mm

mm

mm

mm

mm

±mm

Ω / km

MΏ-km

V/5min.

A

kg/km

3

25

7/

2.14

6.42

3.4

1.4

46.8

0.4

2.8

55.6

2.7

0.734

1,150

21.5

80

4,860

3

35

7/

2.52

7.56

3.4

1.6

49.6

0.4

2.9

58.6

2.8

0.529

1,020

21.5

99

5,570

3

50

19 /

1.78

8.90

3.4

1.6

52.6

0.4

3.0

61.8

3.0

0.391

900

21.5

123

6,390

3

70

19 /

2.14

10.70

3.4

1.6

56.5

0.4

3.1

66.0

3.1

0.270

780

21.5

152

7,650

3

95

19 /

2.52

12.60

3.4

1.6

60.6

0.4

3.3

70.5

3.3

0.195

690

21.5

185

9,160

3

120

37 /

2.03

14.21

3.4

1.8

64.5

0.4

3.5

74.8

3.5

0.154

620

21.5

213

10,640

3

150

37 /

2.25

15.75

3.4

1.8

67.7

0.4

3.6

78.3

3.6

0.126

570

21.5

245

12,080

3

185

37 /

2.52

17.64

3.4

1.8

71.8

0.4

3.8

82.8

3.8

0.100

520

21.5

280

14,030

3

240

61 /

2.25

20.25

3.4

1.8

77.9

0.4

4.0

89.4

4.1

0.0762

460

21.5

329

17,140

3

300

61 /

2.52

22.68

3.4

1.8

83.1

0.4

4.2

95.0

4.3

0.0607

420

21.5

379

20,160

0

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

Datasheet Ref: OFS-NK-PC-MV-FS www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883

Medium Voltage Power Cables to NEK 606 Specification

BFOU - Power/Control Cables – Single Core, Medium Power, armoured cables

NEK606

8.7/15 kV Fire Resistant

Applicable Standards

IEC

IEEE

NEK 606 IEC 60092-354 IEC 60331 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228

Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009

Conductor Identification One core: Black New harmonised core colours or project specified colours can be supplied upon special request.

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Fire Protection:

Mica Glass Tape

(3) Insulation:

EP-Rubber

(4) Insulation Screen:

Semi-conductive tape or extruded semi-conductive compound.

(5) Metallic Screen:

Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)

(6) Bedding:

Flame retardant halogen free compound. PET Tape

(7) Amour:

Tinned copper wire braid. PET Tape

(8) Outer Sheath:

SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour

Datasheet Ref: OFS-NK-PC-MV-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


8.7/15 kV Fire Resistant

Medium Voltage Power Cables to NEK 606 Specification

BFOU Single Core Armoured Cables Conductor No. of Cores

Nominal Area

Strand

Overall diameter Dia.

Thickness of Thickness of Nominal dia. Insulation inner covering Inner covering

Dia. Of wire for armour

Thickness of sheath

Nominal

Tolerance

Cable Weight

No.

mm²

NO./

mm

mm

mm

mm

mm

mm

mm

mm

±mm

kg/km

1

25

7/

2.14

6.60

4.5

1.0

25.0

0.3

1.9

30.9

1.7

1,520

1

35

7/

2.52

7.90

4.5

1.0

26.1

0.3

1.9

32.0

1.8

1,700

1

50

19 /

1.78

9.10

4.5

1.2

27.9

0.3

2.0

34.0

1.9

1,980

1

70

19 /

2.14

11.00

4.5

1.2

29.5

0.3

2.0

35.6

1.9

2,290

1

95

19 /

2.52

12.90

4.5

1.2

31.3

0.4

2.1

38.1

2.0

2,820

1

120

37 /

2.03

14.50

4.5

1.2

33.0

0.4

2.2

40.0

2.1

3,240

1

150

37 /

2.25

16.20

4.5

1.2

34.4

0.4

2.3

41.6

2.2

3,640

1

185

37 /

2.52

18.00

4.5

1.2

36.3

0.4

2.3

43.5

2.2

4,170

1

240

61 /

2.25

20.60

4.5

1.4

39.5

0.4

2.5

47.1

2.4

5,130

1

300

61 /

2.52

23.10

4.5

1.4

41.9

0.4

2.6

49.7

2.5

6,000

0

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

Datasheet Ref: OFS-NK-PC-MV-FS www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883

Medium Voltage Power Cables to NEK 606 Specification

BFOU - Power/Control Cables – Multi Core, Medium Power, armoured cables

NEK606

8.7/15 kV Fire Resistant

Applicable Standards

IEC

IEEE

NEK 606 IEC 60092-354 IEC 60331 IEC 60332 part 3 (Category A) IEC 60332-1 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC60228

Application Fixed installation for medium voltage (MV) power in both EX and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009

Conductor Identification The individual cores shall be identified by the coloured semiconducting tape or coloured ribbon tape run longitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows: 3 Cores: Off-White (grey), Black and Red Note: picture is for illustration purposes only

New harmonised core colours or project specified colours can be supplied upon special request.

Construction

Specifications

(1) Conductor:

Tinned, annealed stranded compacted copper conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Fire Protection:

Mica Glass Tape

(3) Insulation:

EP-Rubber

(4) Insulation Screen:

Semi-conductive tape or extruded semi-conductive compound.

(5) Metallic Screen:

Tinned copper wire braid (If necessary, suitable tape may be applied on the braid)

(6) Bedding:

Flame retardant halogen free compound. PET Tape

(7) Amour:

Tinned copper wire braid. PET Tape

(8) Outer Sheath:

SHF2 thermoset compound halogen-free & MUD reisistant low temperature (-40 Deg C) Red Outer Sheath Colour

Datasheet Ref: OFS-NK-PC-MV-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


8.7/15 kV Fire Resistant

Medium Voltage Power Cables to NEK 606 Specification

BFOU Multi Core Armoured Cables Overall diameter

Conductor No. of Cores

Nominal Area

Strand

Dia.

Thickness of Thickness of Nominal dia. Insulation inner covering Inner covering

Dia. Of wire for armour

Thickness of sheath

Nominal

Tolerance

Cable Weight

No.

mm²

NO./

mm

mm

mm

mm

mm

mm

mm

mm

±mm

kg/km

3

25

7/

2.14

6.60

4.5

1.6

51.8

0.4

3.0

60.4

2.9

5,500

3

35

7/

2.52

7.90

4.5

1.6

54.2

0.4

3.1

63.0

3.0

6,170

3

50

19 /

1.78

9.10

4.5

1.6

57.2

0.4

3.2

66.2

3.1

7,020

3

70

19 /

2.14

11.00

4.5

1.6

60.6

0.4

3.3

69.8

3.3

8,150

3

95

19 /

2.52

12.90

4.5

1.8

64.9

0.4

3.5

74.5

3.5

9,690

3

120

37 /

2.03

14.50

4.5

1.8

68.6

0.4

3.6

78.4

3.6

11,120

3

150

37 /

2.25

16.20

4.5

1.8

71.6

0.4

3.7

81.6

3.8

12,460

3

185

37 /

2.52

18.00

4.5

1.8

75.7

0.4

3.9

86.1

3.9

14,380

3

240

61 /

2.25

20.60

4.5

1.8

81.6

0.4

4.1

92.4

4.2

17,410

3

300

61 /

2.52

23.10

4.5

2.0

87.2

0.4

4.4

98.6

4.4

20,520

0

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

Datasheet Ref: OFS-NK-PC-MV-FS www.interkab.com FPAL Verify

Verified

No.10049350

ABS


Section 7 Marine Instrument Cables Marine Power & Control Cables

FPAL Verify

Verified No.10049350

ABS

7


BS6883 IEC 600/1000V Fire Resistant

IEC 60092-353 - Power Cables Armoured:

NEK606 NEK606

Marine Cables to IEC 60092-353 Specification

Applicable Standards

IEEE IEEE

IEC 60092-353 IEC 60092-351 IEC 60092-350 IEC 60332 part 3 (Category A) IEC 60331-21 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228

IEC BS6883

Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Conductor Identification One core: Black Two cores: Brown - Blue Two cores + Earth: Brown - Blue - Yellow/Green Three Cores: Brown - Black - Grey Three Cores + Earth: Brown - Black - Grey - Yellow/Green Four Cores: Blue - Brown - Black - Grey Four Cores + Earth: Blue - Brown - Black - Grey - Yellow/Green Five Cores & above: Black numbers on white base. New harmonised core colours or project specified colours can be supplied upon special request

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to IEC 60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Mica tape:

Layer of mica tape

(3) Insulation:

XLPE Complying with IEC 60092-351

(4) Bedding:

Lapped or Extruded Halogen Free Compound

(5) Armour:

Tinned or Plain Copper wire braid to IEC 60092-350

(6) Outer Sheath:

Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359

Datasheet Ref: MC-PC-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000V Fire Resistant

Marine Cables to IEC 60092-353 Specification

Marine Single Core Armoured Cables - Table 1/4 Cable

1 x 10

1 x 16

1 x 25

1 x 35

1 x 50

1 x 70

1 x 95

1 x 120

Approximate Overall Diameter (mm)

10

11

Current rating (A)

72

96

13

14

16.5

18.5

20.5

22.5

127

157

196

242

293

339

Approximate Weight (kg/km)

195

270

390

495

Min. bending radius fixed installation (mm)

60

70

80

85

670

915

1180

1465

100

115

125

135

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

2 x 25

1 x 150

1 x 185

1 x 240

1 x 300

25

28

30.5

34

389

444

522

601

1770

2190

2820

3475

150

170

185

205

Orange

Orange

Orange

Orange

Orange

2 x 35

2 x 50

3 x 1.5

3 x 2.5

3x4 13.5

Marine Multi Core Armoured Cables - Table 2/4 2 x 1.5

2 x 2.5

Approximate Overall Diameter (mm)

Cable

2x4

2x6

2 x 10

11

11.5

Current rating (A)

20

26

Approximate Weight (kg/km)

145

175

225

2 x 16

13

14

16.5

19

23

25

28

11

12.5

34

44

61

82

108

133

167

16

21

28

340

505

700

1130

1420

1860

170

215

275

Min. bending radius fixed installation (mm)

60

70

80

85

100

115

125

140

160

70

75

85

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Marine Multi Core Armoured Cables - Table 3/4 Cable

3x6

3 x 10

3 x 16

3 x 25

3 x 35

3 x 50

3 x 70

3 x 95

3 x 120

4 x 1.5

4 x 2.5

4x4

4x6

4 x 10

Approximate Overall Diameter (mm)

15

17.5

20

25

28

32

37

42

46

12.5

13.5

15.5

16.5

19.5

Current rating (A)

36

50

67

89

110

137

169

205

237

16

21

28

36

50

Approximate Weight (kg/km)

430

595

845

1285

1655

2175

3005

4010

4925

210

260

370

505

720

Min. bending radius fixed installation (mm)

90

105

120

150

170

195

225

255

280

75

85

95

100

120

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Marine Multi Core Armoured Cables - Table 4/4 Cable

4 x 16

4 x 25

4 x 35

4 x 50

5 x 1.5

5 x 2.5

7 x 1.5

7 x 2.5

12 x 1.5

12 x 2.5

19 x 1.5

19 x 2.5

27 x 1.5

27 x 2.5

37 x 1.5

Approximate Overall Diameter (mm)

22.5

27.5

30.5

35.5

13.5

14.5

14.5

16.5

19

21.5

22.5

25

27

30

30

Current rating (A)

67

89

110

137

14

18

12

16

10

13

9

11

8

10

7

Approximate Weight (kg/km)

1050

1570

2035

2700

245

310

295

415

495

665

705

950

965

1325

1260

Min. bending radius fixed installation (mm)

135

165

185

215

85

90

90

100

115

130

135

150

165

180

180

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Datasheet Ref: MC-PC-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 600/1000V Flame Retardant

IEC 60092-353 - Power Cables Armoured:

NEK606

Marine Cables to IEC 60092-353 Specification

Applicable Standards

IEEE

IEC 60092-353 IEC 60092-351 IEC 60092-350 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228

Application IEC

This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Conductor Identification One core: Black Two cores: Brown - Blue Two cores + Earth: Brown - Blue - Yellow/Green Three Cores: Brown - Black - Grey Three Cores + Earth: Brown - Black - Grey - Yellow/Green Four Cores: Blue - Brown - Black - Grey Four Cores + Earth: Blue - Brown - Black - Grey - Yellow/Green Five Cores & above: Black numbers on white base. New harmonised core colours or project specified colours can be supplied upon special request

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to IEC 60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Insulation:

XLPE Complying with IEC 60092-351

(3) Bedding:

Lapped or Extruded Halogen Free Compound

(4) Armour:

Tinned or Plain Copper wire braid to IEC 60092-350

(5) Outer Sheath:

Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359

Datasheet Ref: MC-PC-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000V Flame Retardant

Marine Cables to IEC 60092-353 Specification

Marine Single Core Armoured Cables - Table 1/5 1 x 1.5

1 x 2.5

Approximate Overall Diameter (mm)

Cable

1x4

1x6

1 x 10

1 x 16

1 x 25

1 x 35

1 x 50

5

5.4

6

7

Current rating (A)

23

30

40

52

Approximate Weight (kg/km)

40

50

70

95

140

1 x 70

1 x 95

1 x 120

1 x 150

8

9

11.5

12.5

72

96

127

157

205

320

420

1 x 185

1 x 240

1 x 300

14.5

17

18.5

20.5

23.5

196

242

293

339

389

26

29

31.5

444

522

555

790

1040

1300

1610

2005

601

2615

3235

Min. bending radius fixed installation (mm)

15

20

25

30

35

40

50

50

60

70

75

85

95

160

175

190

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Marine Multi Core Armoured Cables - Table 2/5 Cable

2 x 1.5

2 x 2.5

2x4

2x6

2 x 10

2 x 16

2 x 25

2 x 35

2 x 50

3 x 1.5

3 x 2.5

3x4

3x6

3 x 10

3 x 16

3 x 25

Approximate Overall Diameter (mm)

10

10.5

12

13

15.5

18

22.5

25

26.5

10

11

12.5

14

16.5

19

24

Current rating (A)

20

26

34

44

61

82

108

133

197

16

21

28

36

50

67

89

Approximate Weight (kg/km)

130

160

205

315

480

665

1030

1305

1500

155

195

260

370

570

805

1240

Min. bending radius fixed installation (mm)

60

65

75

80

95

110

135

150

170

60

70

75

85

100

115

145

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Marine Multi Core Armoured Cables - Table 3/5 Cable

3 x 35

3 x 50

3 x 70

3 x 95

3 x 120

3 x 150

4 x 1.5

4 x 2.5

4x4

4x6

4 x 10

4 x 16

4 x 25

4 x 35

4 x 50

Approximate Overall Diameter (mm)

27

31.5

36

40

45

50

11

12.5

13.5

15.5

18

21.5

26.5

29.5

34.5

Current rating (A)

110

137

169

205

237

272

16

21

28

36

50

67

89

110

137

Approximate Weight (kg/km)

1600

2125

2970

3825

4890

5970

180

240

315

475

695

1020

1540

2030

2675

Min. bending radius fixed installation (mm)

165

190

220

240

270

300

70

75

85

95

110

130

160

180

210

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Datasheet Ref: MC-PC-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000V Flame Retardant

Marine Cables to IEC 60092-353 Specification

Marine Multi Core Armoured Cables - Table 4/5 Cable

4 x 10

4 x 16

4 x 25

4 x 35

4 x 50

4 x 70

4 x 95

4 x 120

4 x 150

4 x 185

4 x 240

4 x 300

5 x 1.5

5 x 2.5

7 x 1.5

Nominal Conductor Stranding mm

56/0.52

80/0.52

128/0.52

176/0.52

240/0.52

360/0.52

496/0.52

624/0.52

768/0.52

960/0.52

1280/0.52

1504/0.52

7/0.53

7/0.67

7/0.53

Minimum Overall Diameter (mm)

16.97

19.88

23.76

26.67

30.07

36.37

39.28

43.65

48.01

53.35

59.65

65.96

11.15

12.61

12.12

Maximum Overall Diameter (mm)

17.5

20.5

24.5

27.5

31

37.5

40.5

45

49.5

55

61.5

68

11.5

13

12.5

Approximate Weight (kg/km)

685

980

1460

1940

2640

3710

4810

5960

7370

9040

11510

14270

205

270

250

Hawke Flame Proof Stuffing Gland

-25H-A

-32H-A

-32H-A

-40H-A

-40H-A

-50H-A

-50H-A

-63H-A

-63H-A

-63H-A

-75H-A

-75H-A

-20SH-A

-20H-A

-20H-A

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Marine Multi Core Armoured Cables - Table 5/5 Cable

7 x 2.5

10 x 1.5

12 x 1.5

12 x 2.5

14 x 1.5

17 x 1.5

19 x 1.5

19 x 2.5

24 x 1.5

27 x 1.5

27 x 2.5

30 x 1.5

37 x 1.5

37 x 2.5

Nominal Conductor Stranding mm

7/0.67

7/0.53

7/0.53

7/0.67

7/0.53

7/0.53

7/0.53

7/0.67

7/0.53

7/0.53

7/0.67

7/0.53

7/0.53

7/0.67

Minimum Overall Diameter (mm)

14.06

16

16.49

17.94

16.97

17.94

19.4

21.82

22.79

23.28

25.7

24.25

25.7

29.1

Maximum Overall Diameter (mm)

14.5

16.5

17

18.5

17.5

18.5

20

22.5

23.5

24

26.5

25

26.5

30

Approximate Weight (kg/km)

380

400

440

585

490

540

620

870

790

850

1170

930

1090

1530

Hawke Flame Proof Stuffing Gland

-25H-A

-25H-A

-25H-A

-25H-A

-25H-A

-25H-A

-25H-A

-32H-A

-32H-A

-32H-A

-40H-A

-32H-A

-40H-A

-40H-A

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Datasheet Ref: MC-PC-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 IEC 150/250V Fire Resistant

IEC 60092-376 - Instrumentation Cables Armoured - Collective Screen

NEK606 NEK606

Marine Cables to IEC 60092-376 Specification

Applicable Standards

IEC BS6883

IEEE IEEE

IEC 60092-376 IEC 60092-351 IEC 60092-350 IEC 60332 part 3 (Category A) IEC 60331-21 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228

Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Conductor Identification Pair: White / Blue with printed pair number Triple: White / Blue / Brown with printed triple number New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to IEC 60228 Class 2

(2) Mica tape:

Layer of mica tape

(3) Insulation:

XLPE Complying with IEC 60092-351

(4) Bedding:

Lapped polyester tape / filler tape

(5) Armour:

Copper wire braid with copper drain wire to IEC 60092-350

(6) Outer Sheath:

Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359

Datasheet Ref: MC-INS-CS-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250V Fire Resistant

Marine Cables to IEC 60092-376 Specification

Marine Instrumentation Armoured Cables - Collective Screen - Table 1/3 Cable

1x2x0.75

2x2x0.75

4x2x0.75

7x2x0.75

8x2x0.75

10x2x0.75

12x2x0.75

14x2x0.75

19x2x0.75

24x2x0.75

Approximate Overall Diameter (mm)

9.5

11

16.5

20

21

24.5

25.5

27

1

34.5

Approximate Weight (kg/km)

115

160

325

465

510

630

705

800

1015

1245

Min. bending radius fixed installation (mm)

60

70

100

120

130

150

155

165

190

210

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Marine Instrumentation Armoured Cables - Collective Screen - Table 2/3

Cable

1x3x0.75

2x3x0.75

4x3x0.75

7x3x0.75

10x3x0.75

1x2x1.5

2x2x1.5

4x2x1.5

7x2x1.5

Approximate Overall Diameter (mm)

8.5

13

14.5

18.5

21

10.5

12

18.5

22.5

Approximate Weight (kg/km)

120

260

360

550

750

155

220

430

650

Min. bending radius fixed installation (mm)

50

80

90

115

130

65

75

115

140

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

19x2x1.5

1x3x1.5

2x3x1.5

4x3x1.5

7x3x1.5

Marine Instrumentation Armoured Cables - Collective Screen - Table 3/3

Cable

8x2x1.5

10x2x1.5

12x2x1.5

14x2x1.5

Approximate Overall Diameter (mm)

24

27.5

29

30.5

32.5

9.5

16

17.5

22.5

Approximate Weight (kg/km)

715

875

1000

1125

1280

150

390

500

770

Min. bending radius fixed installation (mm)

140

150

165

175

185

60

100

105

140

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Datasheet Ref: MC-INS-CS-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 IEC 150/250V Fire Resistant

IEC 60092-376 - Instrumentation Cables Armoured - Individual Screen

NEK606 NEK606

Marine Cables to IEC 60092-376 Specification

Applicable Standards

IEC BS6883

IEEE IEEE

IEC 60092-376 IEC 60092-351 IEC 60092-350 IEC 60332 part 3 (Category A) IEC 60331-21 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228

Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Conductor Identification Pair: White / Blue with printed pair number Triple: White / Blue / Brown with printed triple number New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to IEC 60228 Class 2

(2) Mica tape:

Layer of mica tape

(3) Insulation:

XLPE Complying with IEC 60092-351

(4) Individual Screen:

Pairs / Triples screened with plastic coated aluminium tape and a tinned copper drain wire

(5) Bedding:

Lapped polyester tape / filler tape

(6) Armour:

Copper wire braid with copper drain wire to IEC 60092-350

(7) Outer Sheath:

Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359

Datasheet Ref: MC-INS-IS-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250V Fire Resistant

Marine Cables to IEC 60092-376 Specification

Marine Instrumentation Armoured Cables - Individual Screen - Table 1/3 Cable

1x2x0.75

2x2x0.75

4x2x0.75

7x2x0.75

8x2x0.75

Approximate Overall Diameter (mm)

9.5

14.5

17

20

22

Approximate Weight (kg/km)

125

225

355

515

585

10x2x0.75

12x2x0.75

14x2x0.75

19x2x0.75

24x2x0.75

25

26

27.5

32

35

710

800

910

1175

1425

Min. bending radius fixed installation (mm)

60

90

105

125

135

150

155

170

195

215

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Marine Instrumentation Armoured Cables - Individual Screen - Table 2/3

Cable

1x3x0.75

2x3x0.75

4x3x0.75

7x3x0.75

10x3x0.75

1x2x1.5

2x2x1.5

4x2x1.5

7x2x1.5

Approximate Overall Diameter (mm)

11

13.5

15.5

19

22

10.5

16.5

19

23

Approximate Weight (kg/km)

210

280

400

610

850

165

320

475

720

Min. bending radius fixed installation (mm)

65

80

95

115

135

65

100

115

140

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Marine Instrumentation Armoured Cables - Individual Screen - Table 3/3

Cable

8x2x1.5

10x2x1.5

12x2x1.5

14x2x1.5

19x2x1.5

24x2x1.5

1x3x1.5

2x3x1.5

4x3x1.5

Approximate Overall Diameter (mm)

24.5

28

29.5

31.5

33

37

15

16.5

18.5

Approximate Weight (kg/km)

810

985

1145

1295

1500

1970

310

420

550

Min. bending radius fixed installation (mm)

150

170

180

190

200

215

90

100

115

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Datasheet Ref: MC-INS-IS-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 150/250V Flame Retardant

IEC 60092-376 - Instrumentation Cables Armoured - Collective Screen

NEK606

Marine Cables to IEC 60092-376 Specification

Applicable Standards

IEEE

IEC 60092-376 IEC 60092-351 IEC 60092-350 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228

IEC

Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Conductor Identification Pair: White / Blue with printed pair number Triple: White / Blue / Red with printed triple number New harmonised core colours or project specified colours can be supplied upon special request

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to IEC 60228 Class 2

(2) Insulation:

XLPE Complying with IEC 60092-351

(3) Bedding:

Lapped polyester tape / filler tape

(4) Armour:

Copper wire braid with copper drain wire

(5) Outer Sheath:

Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359

Datasheet Ref: MC-INS-CS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250V Flame Retardant

Marine Cables to IEC 60092-376 Specification

Marine Instrumentation Armoured Cables - Collective Screen - Table 1/3 Cable

1x2x0.5

Approximate Overall Diameter (mm)

2x2x0.5

4x2x0.5

Approximate Weight (kg/km)

7x2x0.5

8x2x0.5

7.5

8

85

100

10x2x0.5

12x2x0.5

14x2x0.5

11.5

14

170

245

19x2x0.5

24x2x0.5

14.5

17

17.5

270

350

390

37x2x0.5

1x2x0.75

18.5

21

440

545

2x2x0.75

23.5

28

7.5

9

665

930

95

125

Min. bending radius fixed installation (mm)

45

50

70

85

90

105

105

115

130

145

170

45

55

Sheath Colour

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Marine Instrumentation Armoured Cables - Collective Screen - Table 2/3 Cable

4x2x0.75

7x2x0.75

8x2x0.75

1x3x0.75

2x3x0.75

4x3x0.75

7x3x0.75

10x3x0.75

Approximate Overall Diameter (mm)

12.5

15.5

16

10x2x0.75 12x2x0.75 14x2x0.75 19x2x0.75 24x2x0.75 18.5

19

20.5

23.5

26

8

12

13

17

19.5

Approximate Weight (kg/km)

215

330

375

440

490

565

715

860

100

200

250

420

580

Min. bending radius fixed installation (mm)

75

95

100

115

115

125

146

160

50

75

80

105

120

Sheath Colour

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Marine Instrumentation Armoured Cables - Collective Screen - Table 3/3 Cable

1x2x1.5

2x2x1.5

4x2x1.5

7x2x1.5

8x2x1.5

10x2x1.5

12x2x1.5

14x2x1.5

19x2x1.5

1x3x1.5

2x3x1.5

4x3x1.5

Approximate Overall Diameter (mm)

10

11

17

20

21.5

24.5

25.5

27

31

9

14.5

16.5

7x3x1.5 21

Approximate Weight (kg/km)

140

190

375

545

625

760

855

960

1230

140

300

430

660

Min. bending radius fixed installation (mm)

60

70

105

120

130

150

155

165

190

50

90

100

125

Sheath Colour

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Datasheet Ref: MC-INS-CS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 150/250V Flame Retardant

IEC 60092-376 - Instrumentation Cables Armoured - Individual Screen

NEK606

Marine Cables to IEC 60092-376 Specification

Applicable Standards

IEEE

IEC 60092-376 IEC 60092-351 IEC 60092-350 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228

IEC

Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Conductor Identification Pair: White / Blue with printed pair number Triple: White / Blue / Red with printed triple number New harmonised core colours or project specified colours can be supplied upon special request

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to IEC 60228 Class 2

(2) Insulation:

XLPE Complying with IEC 60092-351

(3) Individual Screen:

Pairs / Triples screened with plastic coated aluminium tape and a tinned copper drain wire

(4) Bedding:

Lapped polyester tape / filler tape

(5) Armour:

Copper wire braid with copper drain wire

(6) Outer Sheath:

Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359

Datasheet Ref: MC-INS-IS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250V Flame Retardant

Marine Cables to IEC 60092-376 Specification

Marine Instrumentation Armoured Cables - Individual Screen - Table 1/3 Cable

2x2x0.5

4x2x0.5

7x2x0.5

10x2x0.5

14x2x0.5

19x2x0.5

24x2x0.5

1x2x0.75

2x2x0.75

4x2x0.75

7x2x0.75

Approximate Overall Diameter (mm)

9.5

11

13

15.5

17

19.5

22

8

11.5

13

15.5

Approximate Weight (kg/km)

140

170

250

380

40

600

740

95

170

240

375

Min. bending radius fixed installation (mm)

60

65

75

100

110

120

130

50

70

75

100

Sheath Colour

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

24x2x0.75

2x3x0.75

4x3x0.75

7x3x0.75

10x3x0.75

Marine Instrumentation Armoured Cables - Individual Screen - Table 2/3 Cable

8x2x0.75

10x2x0.75

12x2x0.75

14x2x0.75

19x2x0.75

1x2x1.5

Approximate Overall Diameter (mm)

16.5

19

20

21

24

27

12.5

13.5

18

20.5

10

Approximate Weight (kg/km)

420

520

585

650

835

1035

230

290

500

700

150

Min. bending radius fixed installation (mm)

105

115

120

130

145

160

75

80

110

120

60

Sheath Colour

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

19x2x1.5

2x3x1.5

4x3x1.5

Marine Instrumentation Armoured Cables - Individual Screen - Table 3/3 Cable

2x2x1.5

4x2x1.5

7x2x1.5

8x2x1.5

10x2x1.5

12x2x1.5

14x2x1.5

Approximate Overall Diameter (mm)

14.5

17

20

22

25

26

28

32

15.5

17.5

Approximate Weight (kg/km)

255

415

610

700

855

965

1105

1440

380

490

Min. bending radius fixed installation (mm)

85

105

125

130

150

155

165

190

95

110

Sheath Colour

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Datasheet Ref: MC-INS-IS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


IEC BS6883

Marine Cables Cables to to IEC IEC 60092-353 60092-353 Specification Specification Marine

IEC 60092-353 - Power Cables Unarmoured:

NEK606 NEK606

600/1000V 600/1000V Flame Retardant Fire Resistant

Applicable Standards

IEEE IEEE

IEC 60092-353 IEC 60092-351 IEC 60332 part 3 (Category A) IEC 60331-21 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228

IEC BS6883

Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Conductor Identification One core: Black Two cores: Brown - Blue Two cores + Earth: Brown - Blue - Yellow/Green Three Cores: Brown - Black - Grey Three Cores + Earth: Brown - Black - Grey - Yellow/Green Four Cores: Blue - Brown - Black - Grey Four Cores + Earth: Blue - Brown - Black - Grey - Yellow/Green Five Cores & above: Black numbers on white base. New harmonised core colours or project specified colours can be supplied upon special request

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to IEC 60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Mica tape:

Layer of mica tape

(3) Insulation:

XLPE Complying with IEC 60092-351

(4) Bedding:

Lapped or Extruded Halogen Free Compound

(5) Outer Sheath:

Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359

Datasheet Ref: MC-PC-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000V Fire Resistant

Marine Cables to IEC 60092-353 Specification

Marine Single and Multi Core Unarmoured Cables - Table 1/3 Cable

1 x 25

1 x 35

1 x 50

1 x 70

1 x 95

1 x 120

2 x 1.5

2 x 2.5

2x4

2x6

2 x 10

2 x 16

3 x 1.5

Approximate Overall Diameter (mm)

10.5

11.5

13

15

17.5

20

9.5

10

12

13

15

17.5

10

3 x 2.5 11

Current rating (A)

127

157

196

242

293

339

20

26

34

44

61

82

16

21

Approximate Weight (kg/km)

310

410

560

780

1030

1290

100

125

165

265

380

555

125

160

Min. bending radius fixed installation (mm)

85

90

100

115

130

145

60

65

70

80

90

105

65

70

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Marine Multi Core Unarmoured Cables - Table 2/3 Cable

3x4

3x6

3 x 10

3 x 16

3 x 25

3 x 35

3 x 50

3 x 70

3 x 95

4 x 1.5

4 x 2.5

4x4

4x6

4 x 10

Approximate Overall Diameter (mm)

11.5

13

16

18.5

21.5

24.5

29

33

37

11

11.5

13.5

15

17

Current rating (A)

28

36

50

67

89

110

137

169

205

16

21

28

36

50

Approximate Weight (kg/km)

220

325

490

725

1100

1470

1955

2780

3655

150

205

280

410

605

Min. bending radius fixed installation (mm)

75

85

100

115

140

160

180

210

235

70

75

85

95

110

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Marine Multi Core Unarmoured Cables - Table 3/3 Cable

4 x 16

4 x 25

4 x 35

4 x 50

5 x 1.5

5 x 2.5

7 x 1.5

7 x 2.5

12 x 1.5

12 x 2.5

19 x 1.5

19 x 2.5

27 x 1.5

37 x 1.5

Approximate Overall Diameter (mm)

20.5

24

27.5

31.5

11.5

13

13

14.5

16.5

18.5

19.5

22

24

27

Current rating (A)

67

89

110

137

14

18

12

16

10

13

9

11

8

7

Approximate Weight (kg/km)

915

1405

1875

2510

190

251

235

315

380

525

580

795

800

1055

Min. bending radius fixed installation (mm)

125

155

175

205

75

85

80

90

105

120

130

140

155

170

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Datasheet Ref: MC-PC-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 600/1000V Flame Retardant

IEC 60092-353 - Power Cables Unarmoured:

NEK606

Marine Cables to IEC 60092-353 Specification

Applicable Standards

IEEE

IEC 60092-353 IEC 60092-351 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228

Application IEC

This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Conductor Identification One core: Black Two cores: Brown - Blue Two cores + Earth: Brown - Blue - Yellow/Green Three Cores: Brown - Black - Grey Three Cores + Earth: Brown - Black - Grey - Yellow/Green Four Cores: Blue - Brown - Black - Grey Four Cores + Earth: Blue - Brown - Black - Grey - Yellow/Green Five Cores & above: Black numbers on white base. New harmonised core colours or project specified colours can be supplied upon special request

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to IEC 60228 Class 2 (Flexible Class 5 conductors available upon request)

(2) Insulation:

XLPE Complying with IEC 60092-351

(3) Bedding:

Lapped or Extruded Halogen Free Compound

(4) Outer Sheath:

Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359

Datasheet Ref: MC-PC-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000V Flame Retardant

Marine Cables to IEC 60092-353 Specification

Marine Single Core Unarmoured Cables - Table 1/5 1 x 1.5

1 x 2.5

Approximate Overall Diameter (mm)

Cable

1x4

1x6

1 x 10

1 x 16

1 x 25

1 x 35

1 x 50

5

5.4

6

7

Current rating (A)

23

30

40

52

Approximate Weight (kg/km)

40

50

70

95

140

1 x 70

1 x 95

1 x 120

1 x 150

8

9

11.5

12.5

72

96

127

157

205

320

420

1 x 185

1 x 240

1 x 300

14.5

17

18.5

20.5

23.5

196

242

293

339

389

26

29

31.5

444

522

555

790

1040

1300

1610

2005

601

2615

3235

Min. bending radius fixed installation (mm)

15

20

25

30

35

40

50

50

60

70

75

85

95

160

175

190

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

2 x 10

2 x 16

2 x 25

2 x 35

2 x 50

3 x 1.5

3 x 2.5

3x4

3x6

3 x 10

3 x 16

3 x 25

Marine Multi Core Unarmoured Cables - Table 2/5 Cable

2 x 1.5

Approximate Overall Diameter (mm)

2 x 2.5

2x4

2x6

8.5

10

11

12

14

16.5

20.5

23.5

25

9

10

11.5

13

15

17.5

22

Current rating (A)

20

26

34

44

61

82

108

133

167

16

21

28

36

50

67

89

Approximate Weight (kg/km)

80

115

155

240

360

525

805

1100

1290

100

145

200

305

460

680

1045

Min. bending radius fixed installation (mm)

35

40

45

50

60

70

85

95

110

40

40

50

55

60

70

90

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

4 x 70

Marine Multi Core Unarmoured Cables - Table 3/5 Cable

3 x 35

3 x 50

3 x 70

3 x 95

3 x 120

3 x 150

4 x 1.5

4 x 2.5

4x4

4x6

4 x 10

4 x 16

4 x 25

4 x 35

4 x 50

Approximate Overall Diameter (mm)

25

29

34

38

42.5

47.5

10

11

12.5

14

17

19.5

24.5

27.5

32.5

38

Current rating (A)

110

137

169

205

237

272

16

21

28

36

50

67

89

110

137

169

Approximate Weight (kg/km)

1425

1910

2740

3600

4525

5585

135

180

260

375

585

875

1355

1825

2460

3515

Min. bending radius fixed installation (mm)

150

175

205

230

255

285

40

45

50

60

70

80

100

165

195

230

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Datasheet Ref: MC-PC-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


600/1000V Flame Retardant

Marine Cables to IEC 60092-353 Specification

Marine Multi Core Unarmoured Cables - Table 4/5 Cable

4 x 95

4 x 120

5 x 1.5

5 x 2.5

5x4

5x6

5 x 10

5 x 16

7 x 1.5

7 x 2.5

10 x 1.5

10 x 2.5

12 x 1.5

12 x 2.5

Approximate Overall Diameter (mm)

42.5

47

11

12

14

15.5

18

21.5

12

13.5

15

17

15.5

17.5

Current rating (A)

205

237

14

18

25

30

44

56

12

16

11

14

10

13

Approximate Weight (kg/km)

4670

5820

160

220

315

465

710

1065

200

285

290

415

335

470

Min. bending radius fixed installation (mm)

255

285

45

50

60

65

75

90

50

55

60

70

65

70

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Marine Multi Core Unarmoured Cables - Table 5/5 Cable

14 x 1.5

14 x 2.5

16 x 1.5

16 x 2.5

19 x 1.5

19 x 2.5

24 x 1.5

24 x 2.5

27 x 1.5

27 x 2.5

37 x 1.5

37 x 2.5

Approximate Overall Diameter (mm)

16.4

18.5

17.5

19.5

18.5

20.5

22

25

22.5

25.5

25

28

Current rating (A)

10

13

9

12

9

11

8

10

8

10

7

9

Approximate Weight (kg/km)

375

545

425

615

490

700

635

915

690

1005

910

1300

Min. bending radius fixed installation (mm)

70

75

70

80

75

85

90

150

90

155

150

195

Sheath Colour

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Black

Datasheet Ref: MC-PC-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 IEC 150/250V Fire Resistant

IEC 60092-376 - Instrumentation Cables Unarmoured - Collective Screen

NEK606 NEK606

Marine Cables to IEC 60092-376 Specification

Applicable Standards

IEC BS6883

IEEE IEEE

IEC 60092-376 IEC 60092-351 IEC 60092-350 IEC 60332 part 3 (Category A) IEC 60331-21 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228

Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Conductor Identification Pair: White / Blue with printed pair number Triple: White / Blue / Brown with printed triple number New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to IEC 60228 Class 2

(2) Mica tape:

Layer of mica tape

(3) Insulation:

XLPE Complying with IEC 60092-351

(4) Bedding:

Lapped polyester tape / filler tape

(5) Outer Sheath:

Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359

Datasheet Ref: MC-INS-CS-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250V Fire Resistant

Marine Cables to IEC 60092-376 Specification

Marine Instrumentation Unarmoured Cables - Collective Screen - Table 1/3 Cable

1x2x0.5

2x2x0.5

4x2x0.5

Approximate Overall Diameter (mm)

6

6.5

9.5

Approximate Weight (kg/km)

50

60

100

Min. bending radius fixed installation (mm)

45

50

55

Sheath Colour

Orange

Orange

Orange

7x2x0.5

10x2x0.5

14x2x0.5

11

13

14.5

150

220

270

65

80

85

Orange

Orange

Orange

19x2x0.5

24x2x0.5

1x2x0.75

2x2x0.75

17

19

8.5

10

350

450

75

120

100

115

55

60

Orange

Orange

Orange

Orange

Marine Instrumentation Unarmoured Cables - Collective Screen - Table 2/3 Cable

4x2x0.75

7x2x0.75

8x2x0.75

Approximate Overall Diameter (mm)

15.5

18.5

20

Approximate Weight (kg/km)

215

330

380

Min. bending radius fixed installation (mm)

95

115

120

Sheath Colour

Orange

Orange

Orange

10x2x0.75

12x2x0.5

14x2x0.75

19x2x0.75

24x2x0.75

23

24

25.5

29.5

33.5

480

545

620

805

1030

140

145

155

180

205

Orange

Orange

Orange

Orange

Orange

1x3x0.75

2x3x0.75

4x3x0.75

7

11

12.5

70

150

190

50

65

75

Orange

Orange

Orange

4x3x1.5

Marine Instrumentation Unarmoured Cables - Collective Screen - Table 3/3 Cable

7x3x0.75

10x3x0.75

1x2x1.5

2x2x1.5

4x2x1.5

7x2x1.5

10x2x1.5

14x2x1.5

19x2x1.5

1x3x1.5

2x3x1.5

Approximate Overall Diameter (mm)

15.5

18

8

9

13.5

16.5

20

22.5

26

9

13.5

15

Approximate Weight (kg/km)

310

440

90

130

230

370

510

690

910

100

240

320

Min. bending radius fixed installation (mm)

95

115

50

55

85

100

125

135

155

55

85

95

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Datasheet Ref: MC-INS-CS-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 IEC 150/250V Fire Resistant

IEC 60092-376 - Instrumentation Cables Unarmoured - Individual Screen

NEK606 NEK606

Marine Cables to IEC 60092-376 Specification

Applicable Standards

IEC BS6883

IEEE IEEE

IEC 60092-376 IEC 60092-351 IEC 60092-350 IEC 60332 part 3 (Category A) IEC 60331-21 IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228

Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Conductor Identification Pair: White / Blue with printed pair number Triple: White / Blue / Brown with printed triple number New harmonised core colours or project specified colours can be supplied upon special request Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to IEC 60228 Class 2

(2) Mica tape:

Layer of mica tape

(3) Insulation:

XLPE Complying with IEC 60092-351

(4) Individual Screen:

Pairs / Triples screened with plastic coated aluminium tape and a tinned copper drain wire

(5) Bedding:

Lapped polyester tape / filler tape

(6) Outer Sheath:

Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359

Datasheet Ref: MC-INS-IS-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250V Fire Resistant

Marine Cables to IEC 60092-376 Specification

Marine Instrumentation Unarmoured Cables - Individual Screen - Table 1/3 Cable

1x2x0.5

2x2x0.5

4x2x0.5

Approximate Overall Diameter (mm)

6

8.5

10

Approximate Weight (kg/km)

50

90

120

7x2x0.5

10x2x0.5

14x2x0.5

19x2x0.5

24x2x0.5

1x2x0.75

2x2x0.75

4x2x0.75

12

14

15.5

18.5

190

260

340

460

20.5

6

6.5

11.5

580

50

60

130

Min. bending radius fixed installation (mm)

40

55

60

70

90

95

115

125

40

40

65

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

19x2x0.75

24x2x0.75

1x3x0.75

2x3x0.75

4x3x0.75

7x3x0.75 16.5

Marine Instrumentation Unarmoured Cables - Individual Screen - Table 2/3 Cable

7x2x0.75

8x2x0.75

10x2x0.75

12x2x0.75

14x2x0.75

Approximate Overall Diameter (mm)

14

15

17

18

19

22

24.5

7

11.5

13

Approximate Weight (kg/km)

260

270

370

395

490

650

840

70

160

220

350

Min. bending radius fixed installation (mm)

90

95

105

110

115

135

150

45

70

80

100

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

10x2x1.5

14x2x1.5

19x2x1.5

1x3x1.5

2x3x1.5

4x3x1.5

Marine Instrumentation Unarmoured Cables - Individual Screen - Table 3/3 Cable

10x3x0.75

1x2x1.5

2x2x1.5

4x2x1.5

7x2x1.5

Approximate Overall Diameter (mm)

19

8

12

14

17.5

21

23.5

27

8.5

14

16

Approximate Weight (kg/km)

510

90

190

270

440

610

820

1020

100

260

350

Min. bending radius fixed installation (mm)

115

50

70

90

105

125

145

165

50

85

100

Sheath Colour

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Orange

Datasheet Ref: MC-INS-IS-FS

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 150/250V Flame Retardant

IEC 60092-376 - Instrumentation Cables Unarmoured - Collective Screen

NEK606

Marine Cables to IEC 60092-376 Specification

Applicable Standards

IEEE

IEC 60092-376 IEC 60092-351 IEC 60092-350 IEC 60092-359 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228

IEC

Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Conductor Identification Pair: White / Blue with printed pair number Triple: White / Blue / Red with printed triple number New harmonised core colours or project specified colours can be supplied upon special request

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to IEC 60228 Class 2

(2) Insulation:

XLPE Complying with IEC 60092-351

(3) Screen:

Aluminium polyester tape coverage 100%/ copper drain wire

(4) Outer Sheath:

Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359

Datasheet Ref: MC-INS-CS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250V Flame Retardant

Marine Cables to IEC 60092-376 Specification

Marine Instrumentation Unarmoured Cables - Collective Screen - Table 1/3 Cable

1x2x0.5

2x2x0.5

4x2x0.5

7x2x0.5

8x2x0.5

10x2x0.5

12x2x0.5

14x2x0.5

19x2x0.5

24x2x0.5

37x2x0.5

Approximate Overall Diameter (mm)

6

7

10.5

12.5

13.5

15.5

16

17.5

20

22

27

Approximate Weight (kg/km)

45

65

120

175

200

245

280

315

410

515

745

Min. bending radius fixed installation (mm)

40

45

65

75

85

95

100

105

120

135

165

Sheath Colour

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

14x2x0.75

19x2x0.75

24x2x0.75

2x3x0.75

Marine Instrumentation Unarmoured Cables - Collective Screen - Table 2/3 Cable

1x2x0.75

2x2x0.75

4x2x0.75

7x2x0.75

8x2x0.75

10x2x0.75

12x2x0.75

Approximate Overall Diameter (mm)

6.5

7.5

11.5

14

15

17

18

19

22

24.5

11

Approximate Weight (kg/km)

55

80

150

225

260

320

365

415

555

680

150

Min. bending radius fixed installation (mm)

40

45

70

85

90

105

110

115

135

150

65

Sheath Colour

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

10x2x1.5

14x2x1.5

19x2x1.5

2x3x1.5

4x3x1.5

Marine Instrumentation Unarmoured Cables - Collective Screen - Table 3/3 Cable

4x3x0.75

7x3x0.75

Approximate Overall Diameter (mm)

12

15.5

Approximate Weight (kg/km)

190

310

Min. bending radius fixed installation (mm)

70

95

Sheath Colour

Grey

Grey

10x3x0.75

2x2x1.5

4x2x1.5

7x2x1.5

18

9

13.5

16.5

20

22.5

26

13.5

15

440

130

230

370

510

690

910

240

320

105

55

85

100

120

140

155

85

90

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Datasheet Ref: MC-INS-CS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


BS6883 150/250V Flame Retardant

IEC 60092-376 - Instrumentation Cables Unarmoured - Individual Screen

NEK606

Marine Cables to IEC 60092-376 Specification

Applicable Standards

IEEE

IEC 60092-376 IEC 60092-351 IEC 60092-350 IEC 60092-359 IEC 60332 part 3 (Category A) IEC 60754-1 IEC 61034 Stranded class 2 or tinned annealed copper conductors to IEC 60228

IEC

Application This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Conductor Identification Pair: White / Blue with printed pair number Triple: White / Blue / Red with printed triple number New harmonised core colours or project specified colours can be supplied upon special request

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor to IEC 60228 Class 2

(2) Insulation:

XLPE Complying with IEC 60092-351

(3) Individual Screen:

Pairs / Triples screened with plastic coated aluminium tape and a tinned copper drain wire

(4) Screen:

Aluminium polyester tape coverage 100%/ copper drain wire

(5) Outer Sheath:

Halogen Free Polyolefin SHF1 Compound Complying with IEC 60092-359

Datasheet Ref: MC-INS-IS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


150/250V Flame Retardant

Marine Cables to IEC 60092-376 Specification

Marine Instrumentation Unarmoured Cables - Individual Screen - Table 1/3 Cable

1x2x0.5

2x2x0.5

4x2x0.5

7x2x0.5

Approximate Overall Diameter (mm)

6

9.5

11

13

Approximate Weight (kg/km)

50

95

145

220

Min. bending radius fixed installation (mm)

50

60

65

80

Sheath Colour

Grey

Grey

Grey

Grey

8x2x0.5

10x2x0.5

12x2x0.5

14x2x0.5

19x2x0.5

24x2x0.5

14

16

16.5

245

305

350

85

95

Grey

Grey

1x3x0.5

1x2x0.75

17.5

20

395

520

22.5

6

6.5

655

55

100

110

60

125

140

50

55

Grey

Grey

Grey

Grey

Grey

Grey

1x3x0.75

2x3x0.75

4x3x0.75

Marine Instrumentation Unarmoured Cables - Individual Screen - Table 2/3 Cable Approximate Overall Diameter (mm) Approximate Weight (kg/km)

2x2x0.75

4x2x0.75

7x2x0.75

8x2x0.75

10x2x0.75 12x2x0.75 14x2x0.75 19x2x0.75 24x2x0.75

10

12

14.5

15

17.5

18

19.5

22.5

23

7

11.5

13

115

180

275

310

380

440

520

680

840

70

160

220

Min. bending radius fixed installation (mm)

65

75

90

95

105

110

120

135

155

50

70

80

Sheath Colour

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

10x2x1.5

14x2x1.5

19x2x1.5

1x3x1.5

2x3x1.5

4x3x1.5

Marine Instrumentation Unarmoured Cables - Individual Screen - Table 3/3 Cable

7x3x0.75

Approximate Overall Diameter (mm)

10x3x0.75

1x2x1.5

16.5

19

8

Approximate Weight (kg/km)

350

510

90

2x2x1.5

4x2x1.5

7x2x1.5

12

14

17.5

21

23.5

27

8.5

14

16

190

270

440

610

820

1020

100

260

350

Min. bending radius fixed installation (mm)

100

120

50

75

85

110

130

145

165

50

85

95

Sheath Colour

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Grey

Datasheet Ref: MC-INS-IS-FR

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


Section 8 Offshore Fibre Optic Cables

FPAL Verify

Verified No.10049350

ABS

8


MARINE NEK606

AICI Fibre Optic Cable

(1)

Applicable Standards

(2) (3) (4)

IEEE

IEC 60332-1 IEC 60332-3-22 IEC 60754-1-2 IEC 61034-1-2

Optical cable for industrial environments. The cable is suitable

(5)

for both indoor and outdoor installation. Continiuous submergence in water is not recommended. The outer sheath

IEC

Application

is made from black UV-stabilized and weather resistant

(6)

material which is SHF1 classified, and may be exposed for shorter periods to fluids such as diesel and mineral oils. The resistance to these fluids is according to IEC60811-2-1.

Note: picture is for illustration purposes only

Construction

Specifications

(1) Central Strength Member:

Dielectric Strength Member (FRP)

(2) Tight Coating:

850 Micron Tight Buffered Optical Fibres

Fibre Colour Code: Cable Core Stranded:

EIA/TIA 598 The Fibres are Bundled Around a Central Strength Member (FRP)

(3) Strain Relief:

Water Blocking Aramid Yarns

(4) Inner Jacket:

Black LSZH, SHF1

(5) Metallic Armour:

Galvanised Steel Wire Braid (GSWB)

(6) Outer Sheath:

Black LSZH SHF1

Datasheet Ref: SC-FIBRE-AICI

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


AICI Fibre Optic Cable Specification

No. of Fibres

Tight Diameter (Micron)

Nominal O.D (mm)

Cable Weight

Tesile Strength Inst. / Oper (N)

2

850 ± 50

7.8

88

500/200

4

850 ± 50

8

98

600/240

8

850 ± 50

9

110

800/350

12

850 ± 50

10

130

1000/400

16

850 ± 50

10.5

165

1000/400

24

850 ± 50

12

190

1200/480

Mechanical & Installation Characteristics

Temp. Range

(Operation)

Temp. Range

(Installation)

-40°C to +70°C -40°C to +70°C

Temp. Range

(Storage)

-40°C to +70°C

Min. Bending radius

(Static)

10 x Ø

Min. Bending radius

(Dynamic)

20 x Ø

Max. Tensile Strength

(Installation)

(IEC 60794-1-2E1)

See Above

Crush

(IEC 60794-1-2E3)

2000 N/100mm

Impact

(IEC 60794-1-2E4)

1 Impact, 25J

Torsion

(IEC 60794-1-2E7)

± 1 turns/ 1 m

Water Tightness*

(IEC 60794-1-2E7)

<3 m/24 Hours

* Steel Wire Braid is not Water Tight

Behaviour Under Fire Conditions

Fire Resistance

IEC 60331-25

Fire Resistance

IEC 60331-25

Flame Retardant

IEC 60332-1-2

No-Fire Propagation

IEC 60332-3-22

Halogen Content

IEC 60754-1-2

Smoke Density

IEC 61034-1-2

Upgraded

750°C, 3 hours

< 1.0 dB/excess loss

1000°C, 3 hours

< 1.5 dB/excess loss

Datasheet Ref: SC-FIBRE-AICI

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


AICI Fibre Optic Cable Optical Characteristics Single Mode IEC 11801 Classification

OS1/OS2

ITU-T Type

G.652D

± 0.4 µm

Mode Field Diameter

at 1310 nm

9.0

Mode Field Diameter

at 1550 nm

10.1 ± 0.5 µm

Cladding Diameter

125.0 ± 0.7 µm

Coating Diameter (nom.)

242 ± 7 µm

Numerical Aperture Attenuation (max.)

Bending Loss (max.) 1 turns D= 30mm

0.13 (nom) at 850 nm

-

at 1300 nm

-

at 1310 nm

≤ 0.35 dB/km

at 1383 nm

≤ 0.35 dB/km

at 1460 nm

≤ 0.25 dB/km

at 1550 nm

≤ 0.21 dB/km

at 1625 nm

≤ 0.23 dB/km

at 1550 nm

≤ 0.25 dB

at 1625 nm Bandwidth

Chromatic Dispersion

Gigabit Ethernet

≤ 1.0 dB

at 850 nm

-

at 1300 nm

-

at 1285 - 1330 nm

≤ 3.0 ps/nm x km

at 1550 nm

≤ 18 ps/nm x km

at 1565 - 1625 nm

≤ 22 ps/nm x km

SX (1310 nm)

10000 m

LX (1550 nm) 10 Gigabit Ethernet

40000 m

SX (1310 nm)

10000 m

LX (1550 nm)

40000 m

Multi Mode 62.5/125

Multi Mode 50/125

IEC 11801 Classification

OM1

OM2

ITU-T Type

-

G.651

Core Diameter

62.5 ± 2.5 µm

50 ± 2.5 µm

Cladding Diameter

125.0 ± 2.0 µm

125.0 ± 2.0 µm

Coating Diameter (nom.)

242 ± 5.0 µm

242 ± 7.0 µm

Numerical Aperture Attenuation (max.)

Bending Loss (max.) 1 turns D= 75mm

0.275 ± 0.015 µm

0.200 ± 0.015 µm

at 850 nm

≤ 3.5 dB/km

≤ 2.8 dB/km

at 1300 nm

≤ 1.0 dB/km

≤ 1.0 dB/km

at 1550 nm

≤ 0.05 dB

≤ 0.5 dB

≤ 0.05 dB

≤ 0.5 dB

≥ 200 MHz x km

≥ 500 MHz x km

at 1300 nm

≥ 500 MHz x km

≥ 500 MHz x km

SX (850 nm)

275 VCLS (m)

550 VCLS (m)

LX (1300 nm)

550 Laser (m)

550 Laser (m)

SX (850 nm)

33 VCSL (m)

82 VCSL (m)

LX (1300 nm)

300 WWDM (m)

300 WWDM (m)

at 1625 nm Bandwidth

Gigabit Ethernet

10 Gigabit Ethernet

at 850 nm

Datasheet Ref: SC-FIBRE-AICI

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


MARINE NEK606

QFCI Fibre Optic Cable

Applicable Standards

IEEE

IEC 60754-1 IEC 61034-2 IEC 60331-25 IEC 60332 part 3 (Category A)

This range of cables is specially designed for use in communication and emergency systems than need to be operational during a fire. These cables are ideal for many different ap-

IEC

Application

plications including the following; PA/GA System, DP System ESD System, Security System & PLC Control System

Note: picture is for illustration purposes only

Construction

Specifications

(1) Central Strength Member:

Steel with Plastic Oversheathing

(2) Loose Tube:

Thermoplastic Material (PBT), Jelly Filled

(3) Fire Barrier:

Fire Resistant Mica/Glass Tapes

Fibre Colour Code:

EIA/TIA 598

Tubes Colour Code:

1 - Red / 2 - Green - Others White

Filler Elements:

Thermoplastic Rods

Cable Core:

Loose Tubes (and Fillers) are stranded around a steel strength member

(4) Wrapping: (5) Inner Jacket:

Black LSZH, SHF1

(6) Metallic Armour:

Galvanised Steel Wire Braid (GSWB)

(7) Outer Sheath:

Black LSZH SHF1

Datasheet Ref: SC-FIBRE-QFCI

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


QFCI Fibre Optic Cable Specification

No. of Fibres

No. of Tubes + Fillers

4

2+2

6

3+2

8

2+2

12

Tube Diameter (mm)

Nominal O.D mm

Cable Weight (kg/km)

2.5

13.5

230

2.5

13.5

230

2.5

13.5

230

3+1

2.5

13.5

230

24

4+0

2.5

13.5

230

36

3+1

3.0

14.5

250

48

4+0

3.0

14.5

250

Mechanical & Installation Characteristics

0

Temp. Range

(Operation)

Temp. Range

(Installation)

-40°C to +70°C

Temp. Range

(Storage)

-40°C to +70°C

Min. Bending radius Min. Bending radius

-40°C to +70°C

(Static)

10 x Ø

(Dynamic)

20 x Ø

Max. Tensile Strength

(Installation)

(IEC 60794-1-2E1)

1500 N

Max. Tensile Strength

(Operation)

(IEC 60794-1-2E1)

500 N

Crush

(IEC 60794-1-2E3)

3000 N/10cm

Impact

(IEC 60794-1-2E4)

20 impacts, 5J

Torsion

(IEC 60794-1-2E7)

± 1 turns/ 1 m

Immersion Test SAE 20 4h/70 ° (IEC 60811-2-1)

PASS

Immersion Test IRM 902 4h/70°

PASS

(IEC 60811-2-1)

Behaviour Under Fire Conditions

Fire Resistance

IEC 60331-25

Fire Resistance

IEC 60331-25

Flame Retardant

IEC 60332-1-2

No-Fire Propagation

IEC 60332-3-22

Halogen Content

IEC 60754-1-2

Smoke Density

IEC 61034-1-2

Upgraded

750°C, 3 hours

< 1.0 dB/excess loss

1000°C, 3 hours

< 1.5 dB/excess loss

Datasheet Ref: SC-FIBRE-QFCI

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


QFCI Fibre Optic Cable Optical Characteristics

Single Mode IEC 11801 Classification

OS1/OS2

ITU-T Type

G.652D

± 0.4 µm

Mode Field Diameter

9.0

Mode Field Diameter

10.1 ± 0.5 µm

Cladding Diameter

125.0 ± 0.7 µm

Coating Diameter (nom.)

242 ± 7 µm

Numerical Aperture Attenuation (max.)

Bending Loss (max.) 1 turns D= 30mm

0.13 (nom) at 850 nm

-

at 1300 nm

-

at 1310 nm

≤ 0.35 dB/km

at 1383 nm

≤ 0.35 dB/km

at 1460 nm

≤ 0.25 dB/km

at 1550 nm

≤ 0.21 dB/km

at 1625 nm

≤ 0.23 dB/km

at 1550 nm

≤ 0.25 dB

at 1625 nm Bandwidth

Chromatic Dispersion

Gigabit Ethernet

≤ 1.0 dB

at 850 nm

-

at 1300 nm

-

at 1285 - 1330 nm

≤ 3.0 ps/nm x km

at 1550 nm

≤ 18 ps/nm x km

at 1565 - 1625 nm

≤ 22 ps/nm x km

SX (1310 nm)

10000 m

LX (1550 nm) 10 Gigabit Ethernet

40000 m

SX (1310 nm)

10000 m

LX (1550 nm)

40000 m

Multi Mode 62.5/125

Multi Mode 50/125

IEC 11801 Classification

OM1

OM2

ITU-T Type

-

G.651

Core Diameter

62.5 ± 2.5 µm

50 ± 2.5 µm

Cladding Diameter

125.0 ± 2.0 µm

125.0 ± 2.0 µm

Coating Diameter (nom.)

242 ± 5.0 µm

242 ± 7.0 µm

Numerical Aperture Attenuation (max.)

Bending Loss (max.) 1 turns D= 75mm

0.275 ± 0.015 µm

0.200 ± 0.015 µm

at 850 nm

≤ 3.5 dB/km

≤ 2.8 dB/km

at 1300 nm

≤ 1.0 dB/km

≤ 1.0 dB/km

at 1550 nm

≤ 0.05 dB

≤ 0.5 dB

≤ 0.05 dB

≤ 0.5 dB

≥ 200 MHz x km

≥ 500 MHz x km

at 1300 nm

≥ 500 MHz x km

≥ 500 MHz x km

SX (850 nm)

275 VCLS (m)

550 VCLS (m)

LX (1300 nm)

550 Laser (m)

550 Laser (m)

SX (850 nm)

33 VCSL (m)

82 VCSL (m)

LX (1300 nm)

300 WWDM (m)

300 WWDM (m)

at 1625 nm Bandwidth

Gigabit Ethernet

10 Gigabit Ethernet

at 850 nm

Datasheet Ref: SC-FIBRE-QFCI

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


MARINE NEK606

QFCI Fibre Optic Cable MUD Resistant

Applicable Standards

IEEE

IEC 60754-1 IEC 61034-2 IEC 60331-25 IEC 60332 part 3 (Category A)

This range of cables is specially designed for use in communication and emergency systems than need to be operational during a fire. These cables are ideal for many different ap-

IEC

Application

plications including the following; PA/GA System, DP System ESD System, Security System & PLC Control System

Note: picture is for illustration purposes only

Construction

Specifications

(1) Central Strength Member:

Steel Strength Member or Glass Fiber Reinforced Plastic (FRP)

(2) Loose Tube:

Thermoplastic Material, Jelly Filled

(3) Fire Barrier:

Fire Resistant Mica/Glass Tape Applied to Each Tube

Fibre Colour Code:

EIA/TIA 598

Tubes Colour Code:

1 - Red / 2 - Green - Others White

Filler Elements:

Thermoplastic Rods, Where Needed

Cable Core:

Loose Tubes (and Fillers) are stranded around a steel strength member

(4) Wrapping: (5) Inner Jacket:

Black LSZH, SHF1

(6) Metallic Armour:

Galvanised Steel Wire Braid (GSWB)

(7) Outer Sheath 1:

LSZH SHF1

(8) Outer Sheath 2:

SHF2 Compound (MUD, Oil, Hydrocarbon Resistant and UV Stabilised)

Datasheet Ref: SC-FIBRE-QFCI-MUD

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


QFCI Fibre Optic Cable MUD Resistant Specification

No. of Fibres

No. of Tubes + Fillers

Tube Diameter (mm)

Nominal O.D mm

Cable Weight (kg/km)

12

3+1

2.5

15

290

24

4+1

2.5

15

290

Mechanical & Installation Characteristics

0

Temp. Range

(Operation)

Temp. Range

(Installation)

-40°C to +70°C -40°C to +70°C

Temp. Range

(Storage)

-40°C to +70°C

Min. Bending radius

(Static)

10 x Ø

Min. Bending radius

(Dynamic)

20 x Ø

Max. Tensile Strength

(Installation)

(IEC 60794-1-2E1)

1500 N

Max. Tensile Strength

(Operation)

(IEC 60794-1-2E1)

500 N

Crush

(IEC 60794-1-2E3)

3000 N/10cm for 15 min

Impact

(IEC 60794-1-2E4)

20 impacts, 5J

Torsion

(IEC 60794-1-2E7)

± 1 turns/ 1 m

Behaviour Under Fire Conditions

Fire Resistance

IEC 60331-25

Fire Resistance

IEC 60331-25

Flame Retardant

IEC 60332-1-2

No-Fire Propagation

IEC 60332-3-22

Halogen Content

IEC 60754-1-2

Smoke Density

IEC 61034-1-2

Upgraded

750°C, 3 hours

< 1.0 dB/excess loss

1000°C, 3 hours

< 1.5 dB/excess loss

Datasheet Ref: SC-FIBRE-QFCI-MUD

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


QFCI Fibre Optic Cable MUD Resistant Optical Characteristics Single Mode IEC 11801 Classification

OS1/OS2

ITU-T Type

G.652D

± 0.4 µm

Mode Field Diameter

at 1310 nm

9.0

Mode Field Diameter

at 1550 nm

10.1 ± 0.5 µm

Cladding Diameter

125.0 ± 0.7 µm

Coating Diameter (nom.)

242 ± 7 µm

Numerical Aperture

0.13 (nom)

Attenuation (max.)

at 850 nm

-

at 1300 nm

-

at 1310 nm

≤ 0.35 dB/km

at 1383 nm

≤ 0.35 dB/km

at 1460 nm

≤ 0.25 dB/km

at 1550 nm

≤ 0.21 dB/km

at 1625 nm

≤ 0.23 dB/km

at 1550 nm

≤ 0.25 dB

Bending Loss (max.) 1 turns D= 30mm

at 1625 nm Bandwidth

≤ 1.0 dB

at 850 nm

-

at 1300 nm

-

at 1285 - 1330 nm

≤ 3.0 ps/nm x km

at 1550 nm

≤ 18 ps/nm x km

at 1565 - 1625 nm

≤ 22 ps/nm x km

SX (1310 nm)

10000 m

Chromatic Dispersion

Gigabit Ethernet

LX (1550 nm)

40000 m

SX (1310 nm)

10000 m

LX (1550 nm)

40000 m

10 Gigabit Ethernet

Multi Mode 62.5/125

Multi Mode 50/125

IEC 11801 Classification

OM1

OM2

ITU-T Type

-

G.651

Core Diameter

62.5 ± 2.5 µm

50 ± 2.5 µm

Cladding Diameter

125.0 ± 2.0 µm

125.0 ± 2.0 µm

Coating Diameter (nom.)

242 ± 5.0 µm

242 ± 7.0 µm

Numerical Aperture Attenuation (max.)

Bending Loss (max.) 1 turns D= 75mm

0.275 ± 0.015 µm

0.200 ± 0.015 µm

at 850 nm

≤ 3.5 dB/km

≤ 2.8 dB/km

at 1300 nm

≤ 1.0 dB/km

≤ 1.0 dB/km

at 1550 nm

≤ 0.05 dB

≤ 0.5 dB

≤ 0.05 dB

≤ 0.5 dB

≥ 200 MHz x km

≥ 500 MHz x km

at 1300 nm

≥ 500 MHz x km

≥ 500 MHz x km

SX (850 nm)

275 VCLS (m)

550 VCLS (m)

LX (1300 nm)

550 Laser (m)

550 Laser (m)

SX (850 nm)

33 VCSL (m)

82 VCSL (m)

LX (1300 nm)

300 WWDM (m)

300 WWDM (m)

at 1625 nm Bandwidth

Gigabit Ethernet

10 Gigabit Ethernet

at 850 nm

Datasheet Ref: SC-FIBRE-QFCI-MUD

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


Section 9 Coaxial Cables

FPAL Verify

Verified No.10049350

ABS

9


MARINE NEK606

RG11A/U 75 Ohm Coaxial Cable

Applicable Standards

IEEE

DIN EN 13602 Cu-ETP-A...-B DIN EN 50290-2-29 IEC 60092-359 / SHF-2 IEC 60332 part 3 (Category A)

Application IEC

This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor

(2) Insulation:

Polyethylene

(3) Armour:

Bare Copper Braid

(4) Outer Sheath:

SHF2

Datasheet Ref: SC-COAX-RG11A-SHF2

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


RG11A/U 75 Ohm Coaxial Cable Electrical Characteristics

Electrical Characteristics @ 20°C Stranding mm

7/0.4

Inner Conductor Diameter mm

1.21

Insulation Diameter mm

7.25

Armour/Braid Diameter mm

8

Overall Diameter (min/max) mm

10.0/10.6

Conductor Resistance – Ohm/km

≤ 22 ≥ 10

Insulation Resistance – GOhm/km Capacitance 1 KHz – nF/m

≈ 68

Characteristic Impedance Ohm

75 ± 3

Operating Voltage V

≤ 300

Test Voltage (wire/screen)

2000V rms 50 Hz 1min

Re. Velocity of Propagation %

66

Frequency (MHz)

Attenuation dB/100m

5

1.3

10

1.8

50

4.1

100

6.1

200

9

300

11.4

500

15.5

1000

24

2000

39.5

2500

47.5

Other Characteristics

Other Characteristics RoHS Compliant Permissable Temperature Range °C

- 40 up to + 105

Min. Bending radius allowed:

8 x OD repeated, 4 x single

Weight kg/km

145

Datasheet Ref: SC-COAX-RG11A-SHF2

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com

FPAL Verify

Verified

No.10049350

ABS


MARINE NEK606

RG58C/U 50 Ohm Coaxial Cable

Applicable Standards

IEEE

DIN EN 13602 Cu-ETP-R...-B DIN EN 50290-2-23 IEC 60092-359 / SHF1-1 IEC 60332 part 3 (Category A)

Application IEC

This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Tinned Stranded Copper Conductor

(2) Insulation:

Polyethylene

(3) Armour:

Tinned Copper Braid

(4) Outer Sheath:

LSZH SHF1

Datasheet Ref: SC-COAX-RG58C-SHF1

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


RG58C/U 50 Ohm Coaxial Cable Electrical Characteristics

Electrical Characteristics @ 20°C

Frequency (MHz)

Attenuation dB/100m

50

12

100

17

200

27

300

34

Stranding mm

19/0.19

Inner Conductor Diameter mm

0.93

Insulation Diameter mm

2.85

Armour/Braid Diameter mm

3.4

Overall Diameter (min/max) mm

4.80/5.10

Conductor Resistance – Ohm/km Insulation Resistance – GOhm/km

≤ 37 ≥ 10

Capacitance 1 KHz – nF/m

≈ 105

500

41

Characteristic Impedance Ohm

50 ± 2

1000

65

Operating Voltage V

≤ 300

Test Voltage (wire/screen)

2000V rms 50 Hz 1min

2000

95

Re. Velocity of Propagation %

66

2500

110

Other Characteristics

Other Characteristics RoHS Compliant Permissable Temperature Range °C

- 25 up to + 80

Min. Bending radius allowed:

10 x OD repeated, 5 x single

Weight kg/km

39

Datasheet Ref: SC-COAX-RG58C-SHF1

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com

FPAL Verify

Verified

No.10049350

ABS


MARINE NEK606

RG59B/U 75 Ohm Coaxial Cable

Applicable Standards

IEEE

DIN EN 13602 Cu-ETP-A... DIN EN 50290-2-23 IEC 60092-359 / SHF-2 IEC 60332 part 3 (Category A)

Application IEC

This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Solid Bare Copper Conductor

(2) Insulation:

Polyethylene

(3) Armour:

Bare Copper Braid

(4) Outer Sheath:

SHF2

Datasheet Ref: SC-COAX-RG59B-SHF2

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


RG59B/U 75 Ohm Coaxial Cable Electrical Characteristics

Electrical Characteristics @ 20°C

Frequency (MHz)

Attenuation dB/100m

50

7.8

100

11.2

200

16.3

Inner Conductor Diameter mm

0.6

Insulation Diameter mm

3.7

Armour/Braid Diameter mm

4.3

Overall Diameter (min/max) mm

5.80/6.20

Conductor Resistance – Ohm/km

300

20.5

Insulation Resistance – GOhm/km

≤ 64 ≥ 10

500

26.7

Capacitance 1 KHz – nF/m

≈ 67

Characteristic Impedance Ohm

75 ± 3

1000

39.5

Operating Voltage (peak) V

≤ 100

2000

59.4

Test Voltage (wire/screen)

2000V rms 50 Hz 1min

2500

67.3

Other Characteristics

Other Characteristics RoHS Compliant Permissable Temperature Range °C

- 40 up to + 80

Min. Bending radius allowed:

10 x OD repeated, 5 x single

Weight kg/km

53

Datasheet Ref: SC-COAX-RG59B-SHF2

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


MARINE NEK606

RG213/U 50 Ohm Coaxial Cable

Applicable Standards

IEEE

DIN EN 13602 Cu-ETP-R... DIN EN 13602 Cu-ETP-A... DIN EN 50290-2-23 IEC 60092-359 / SHF-2 IEC 60332 part 3 (Category A)

Application IEC

This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Bare Stranded Copper Conductor

(2) Insulation:

Polyethylene

(3) Armour:

Bare Copper Braid

(4) Outer Sheath:

SHF2

Datasheet Ref: SC-COAX-RG213-SHF2

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


RG213/U 50 Ohm Coaxial Cable Electrical Characteristics

Frequency (MHz)

Electrical Characteristics @ 20°C Stranding mm

7/0.75

Inner Conductor Diameter mm

2.25

Insulation Diameter mm

7.25

Armour/Braid Diameter mm

8

Overall Diameter (min/max) mm

10.1/10.5

Insulation Resistance – GOhm/km

≤ 6.2 ≥ 10

Capacitance 1 KHz – nF/m

≈ 101

Characteristic Impedance Ohm

50 ± 2

Operating Voltage V

≤ 250

Test Voltage (wire/screen)

1500V rms 50 Hz 1min

Conductor Resistance – Ohm/km

Attenuation dB/100m

100

7.7

200

11.1

300

13.8

400

16.1

500

18.2

1000

27

1300

31

2000

40

2500

46

Other Characteristics

Other Characteristics RoHS Compliant Permissable Temperature Range °C

- 40 up to + 80

Min. Bending radius allowed:

10 x OD repeated, 5 x single

Weight kg/km

160

Datasheet Ref: SC-COAX-RG213-SHF2

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


MARINE NEK606

RG213/U 50 Ohm Coaxial Cable

Applicable Standards

IEEE

DIN EN 13602 Cu-ETP-R... DIN EN 13602 Cu-ETP-A... DIN EN 50290-2-23 IEC 60092-359 / SHF-2 IEC 60332 part 3 (Category A)

Application IEC

This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Bare Stranded Copper Conductor

(2) Insulation:

Polyethylene

(3) Armour:

Bare Copper Braid

(4) Outer Sheath:

SHF2

Datasheet Ref: SC-COAX-RG213-SHF2

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


RG213/U 50 Ohm Coaxial Cable Electrical Characteristics

Frequency (MHz)

Electrical Characteristics @ 20°C Stranding mm

7/0.75

Inner Conductor Diameter mm

2.25

Insulation Diameter mm

7.25

Armour/Braid Diameter mm

8

Overall Diameter (min/max) mm

10.1/10.5

Insulation Resistance – GOhm/km

≤ 6.2 ≥ 10

Capacitance 1 KHz – nF/m

≈ 101

Characteristic Impedance Ohm

50 ± 2

Operating Voltage V

≤ 250

Test Voltage (wire/screen)

1500V rms 50 Hz 1min

Conductor Resistance – Ohm/km

Attenuation dB/100m

100

7.7

200

11.1

300

13.8

400

16.1

500

18.2

1000

27

1300

31

2000

40

2500

46

Other Characteristics

Other Characteristics RoHS Compliant Permissable Temperature Range °C

- 40 up to + 80

Min. Bending radius allowed:

10 x OD repeated, 5 x single

Weight kg/km

160

Datasheet Ref: SC-COAX-RG213-SHF2

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


MARINE NEK606

RG214/U 50 Ohm Coaxial Cable

Applicable Standards

IEEE

DIN EN 13602 Cu-ETP-R... DIN EN 13602 Cu-ETP-A... DIN EN 50290-2-23 IEC 60092-359 / SHF-1 IEC 60332 part 3 (Category A)

Application IEC

This range of cables is designed for use in fixed installation in most areas and on open deck in ships

Note: picture is for illustration purposes only

Construction

Specifications

(1) Conductor:

Stranded Silvered Copper Conductor

(2) Insulation:

Polyethylene

(3) Armour:

Silvered Copper Braid

(4) Armour:

Silvered Copper Braid

(5) Outer Sheath:

LSZH SHF1

Datasheet Ref: SC-COAX-RG214-SHF1

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


RG214/U 50 Ohm Coaxial Cable Electrical Characteristics

Electrical Characteristics @ 20°C Stranding mm

7/0.75

Inner Conductor Diameter mm

2.25

Insulation Diameter mm

7.25

Armour/Braid Diameter mm

7.9

Armour/Braid Diameter mm

8.5

Overall Diameter (min/max) mm

10.5/11.1

Conductor Resistance – Ohm/km Insulation Resistance – GOhm/km

≤ 6.2 ≥ 10

Operating Voltage (peak) V

≤ 250

Characteristic Impedance Ohm Capacitance 800 Hz – pF/m Relative Velocity of Propagation %

66

Test Voltage (wire/screen)

5kV rms 50 Hz 1min

Frequency (MHz)

Attenuation dB/100m

100

6.9

200

10

300

12.5

400

15

500

16.8

1000

25

50 ± 2

1300

29.8

≈ 101

2000

41.6

2500

49.6

Other Characteristics

Other Characteristics RoHS Compliant Permissable Temperature Range °C

- 25 up to + 80

Min. Bending radius allowed:

10 x OD repeated, 5 x single

Weight kg/km

191

Datasheet Ref: SC-COAX-RG214-SHF1

INTERKAB House Aberdeen, AB11 5DY Tel: 0044 (0)1224 595 640 Fax: 0044 (0)1224 594 416 Email: info@interkab.com

www.interkab.com FPAL Verify

Verified

No.10049350

ABS


Aberdeen Head Office

Middle East Regional Office Dubai

CIS Regional Office Kazakhstan

INTERKAB House Links PLace Aberdeen AB11 5DY

INTERKAB 1901 Grosvenor Business Tower TECOM P.O. Box 123560 Dubai

INTERKAB Republic of Kazakhstan Atyrau, Azattyk Avenue, bid. 48 Business Centre ‘Premier Atyrau’ 7-floor

Tel 0044 (0)1224 595 640 Fax 0044 (0)1224 594 416

Tel 00971 43746808 Fax 00971 43746806

Tel 007 (8) 7122 251197 Fax 007 (8) 7122 251197

www.interkab.com DISCLAIMER All drawings, data and narrative and information contained within this catalogue is for guidance only and provided without warranty.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.