TRANSFER (15 – 18 WEEKS) · How to prepare a flock for transfer to the laying house. · How to transfer a flock correctly to the laying house. · How to house a flock correctly in the laying house.
PREPARING THE FLOCK TO MOVE TO THE LAYING HOUSE It is recommended to transfer the birds between 15 and 18 weeks. The birds should have time to become familiar with the new environment before they start to lay. If the feed and water systems used in the rearing and the laying house are similar it will help the birds make a smooth transition. The same light program as in the rearing house should be applied. As the page 25 graph shows, good communication and coordination between the rearing and the laying house is necessary to synchronize flock management. It is good management practice to visit the pullets several times during the rearing period.
PRODUCTION HOUSE
FLOCK
TRANSPORT
Complete the vaccination program before transfer.
All maintenance completed House clean and disinfected Feed in the silos Correct temperature Sampling of C&D process performed and satisfactory laboratory results received. Pullets on body weight Vaccine program administered Approved Sanitary certificate Flock information sent to production house (lighting program, feeding times, type of feed, body weight, …) Transport truck ready Catching crew ready Housing crew ready Weather condition checked
Where possible do not administer vaccine during the transport or in the catching process.
STOCKING DENSITY IN THE LAYING HOUSE The bird should have enough space, especially in hot climates. Important is not only cm² of cage floor/bird, but also the height of the cage and how many cm of feeder and how many drinkers are available per bird (a minimal recommendation is given in table 5). Overstocking has a strong impact on mortality, body weight and body weight uniformity, feathering status and, finally, in eggs laid per hen. In addition, local legislation should be respected.
24
Table 5: Stocking density at production house Equipment
Requirements*
Stocking Density
450 – 750 cm2/hen
Drinkers Round drinkers Linear drinkers Nipple drinkers
1 drinker (Ø 46 cm) for 125 hens 1 running meter for 80 – 100 hens 1 nipple for 6 – 8 hens (access to 2 nipples/hen)
Feeders Round feeder Chain feeder
1 feeder (Ø 40 cm) for 25 hens 10 – 15 cm/hen
* These recommendations should be adjusted to the local specific regulation.