1 minute read
Derating conditions
Wärtsilä NSD Nederland B.V. Engine type W26 Chapter 1.0 Subject Main data Issue date June '00
Derating conditions
Standard conditions
Max. Nom. Min.
Air temperature engine inlet-marine Air temperature engine inlet-power Site elevation above sea level Barometric pressure L.T. coolant before air cooler-marine L.T. coolant before air cooler-power Pressure loss before the compressor of the turbocharger Pressure loss in the air cooler at max. load of p receiver [ C] 45 - 15 [ C] 35 - 15 [m] [mbar] 100 0 1000 982 [ C] 38 - [ C] 45 - [mbar] 10 - -
[mbar/bar] % (70) 2%
(35) 1% Pressure loss exhaust gas after the turbocharger [mbar] 30 - -