1 minute read

Derating conditions

Wärtsilä NSD Nederland B.V. Engine type W26 Chapter 1.0 Subject Main data Issue date June '00

Derating conditions

Standard conditions

Max. Nom. Min.

Air temperature engine inlet-marine Air temperature engine inlet-power Site elevation above sea level Barometric pressure L.T. coolant before air cooler-marine L.T. coolant before air cooler-power Pressure loss before the compressor of the turbocharger Pressure loss in the air cooler at max. load of p receiver [ C] 45 - 15 [ C] 35 - 15 [m] [mbar] 100 0 1000 982 [ C] 38 - [ C] 45 - [mbar] 10 - -

[mbar/bar] % (70) 2%

(35) 1% Pressure loss exhaust gas after the turbocharger [mbar] 30 - -

Note: For exact values, see order specification

NOTE: For higher temperatures the output of the engine has to be corrected according the drawing curves or according to ISO 3046/1 (mechanical efficiency is 0,9). No compensation is allowed for conditions better than specified.