1 minute read

Electrical systems – 5000

Parameters & adjustments

# 22 - Machine type

This parameter should be set according to the type of truck.

0= 7LOP10CW

1= 7LOP10CF

# 23 - Function selection

This parameter activates a number of different travel and lift functions.

0= The truck can be driven with the operator standing next to the truck.

1= The truck CANNOT be driven with the operator standing next to the truck.

2= Activate the “Walkie” button (not used)

3= A combination of mode 1 & 2

4= The pallet stops 100 mm above ground when lowering the forks (“Pallet to ground” function)

5= A combination of modes 1 & 4

6= A combination of modes 2 & 4

7= A combination of modes 1 & 2 & 4

# 24 - Special request

The parameters for a special request are entered as follows:

0 = Not activated

1 = Speed restriction. Only 7LOP10CF, special machine plates are required.

# 25 - Service interval

This parameter determines the time value in hours to the next service from 0 to 2000 hours in steps of 50 hours. Whenever this value is changed the timer is reset and will start counting activity time up to the set value. On reaching the set value caution code 29 (C29) will be shown on the display.

# 28 - Button selection

This parameter determines which button to be used for lifting/lowering.

1 = Lower lift/lower button activated (default)

2 = Upper lift/lower button activated

3 = Both lift/lower buttons are activated.

This article is from: