1 minute read
4. Fuel demand valve (FDV) requirement
4. Fuel demand valve (FDV) requirement
EQUIPPED FOR UNITED STATES AND CANADA MODEL
The fuel demand valve prevents pressurized fuel from entering the engine and causing a possible fuel spillage. The fuel demand valve has a manual release. The manual release can be used (pushed in) to open (bypass) the valve in case of a fuel blockage in the valve.
Manual release
Fuel demand valve
! CAUTION
Be sure to use EPA approved tank and FDV as a set. Confirm shapes of EPA approved tank and regular tank.
Except for U.S. model (regular tank) For U.S. and Canada model (EPA approved tank)
5
Vent/water drain holes
Fuel demand valve - installed in the fuel hose between the fuel tank and primer bulb.
! CAUTION
● Do not make demand valve wet with water, gasoline or oil or, the function will be deteriorated. ● Located demand valve in a place that can protect it from damaging actions such as stepping on it.