1 minute read
Control, operation
Operating and control elements
S21 – Fast run
Switching of travel drive between normal travel and fast run mode.
Normal travel: maximum drawing pull at moderate speed. Fast run: reduced drawing pull at maximum speed.
On slopes and uneven terrain, the machine shows improved traction when it is set to fast run mode.
S47 - Hydraulic quick-change adapter*
Actuate this switch to activate the hydraulic quick-change adapter for the attachment and removal of working tools. The quick-change adapter can be locked and released.
S241 - Additional users*
This switch determines whether the attachments (additional consumers) or the boom adjustment (if mounted) can be operated.
Depending on the switch position (see chapter "Tool Control"), the consumer is supplied with hydraulic oil at adjusted pressure and flow settings.
S360 - Acknowledgement of quick change adapter buzzer*
Switches off the acoustic warning signal of the quick-change adapter.
A warning signal indicates that the quick-change adapter is not properly locked. If no working tool is to be mounted, it is useful to deactivate the warning signal. This is also recommended to ensure that other buzzer sounds (i.e. from the overload warning system) are actually audible.
S422 - Radio mute mode
The radio mute mode allows you to reduce the volume of the radio to mute level without switching off the radio.
* optional equipment
** only in conjunction with overload warning system (optional equipment)
3.1.3.2Control console B
S1 - Ignition switch
The ignition switch is used to switch on the electrical equipment and to start the machine.
S92 - Air distribution in legroom
This rotary switch is used to adjust the blower air distribution in the legroom. When the switch is in the left position, the air flows from the exit nozzles at the windscreen. When it is in the right position, the air flows through the exit nozzles at the operator seat.
If the rotary switch is set to an intermediate position, the air is distributed between these two opening systems.
S93
- Heating
This rotary switch is used to adjust the temperature of the blower air.
S284 - Blower output
The blower has 4 output levels. The rotary switch is used to adjust the blower output.
S318 - A/c system*
During a/c operation, the blower air is cooled. The cooling effect can be adjusted with the heating S93. The cooling effect is greatest when the heating is switched off (rotary switch S93).