Installation of Arm Cylinder Hoses

(1) Remove the blind plug from the piping at the arm cylinder end, 13038 x 4) with new parts, and connect the arm cylinder hoses 07074-01211 x 2).

Use the split flange, bolt, and other blind parts again. then replace the O-rings (07OOO(PC600: 07074-01215 x 2, PC650:

Precautions

1. Becareful nottoietthearmcylinderrod jump out during operation. 2. After removing the flanges, O-rings, and heads, keep them in a safe place so that they can be used again. 3. When installing the hoses, be extremely careful not to get the O-rings caught. 4. When installing the hoses, be extremely care- ful not to let dirt or dust get into the circuit. - No.

42

Parts sent individually

Part Name Part No. Hose 07074-01215 O-ring 07000-13038 Above parts are for PC600

Hose O-ring 07074-01211 07000-13032 Above parts are for PC650 Q’ty 2 4

2 4