V. OPERATING INFORMATION

Spray System

The spraying system is a constantly-monitored and continuously-adjusted computer-controlled system. The cab-mounted digital monitor receives information from various inputs to help determine GPM (gallons per minute) and GPA (gallons per acre).

Spray System Operation Instructions

1. Calibrate spraying system monitor.

2. Check contents and quantity in spray tank.

NOTE :

Never attempt to operate the spray system without solution in the spray tank. Operating the spray system with no solution in the tank will cause severe da mage and void the warranty.

3. Completely open the tank valves.

4. Start engine and maintain a relatively low engine RPM setting (1,000 RPM). Increase engine RPM slowly until full recommended operating RPM is reached.

5. If desired, activate the agitation system.

6. Turn on the solution pump switch.

7. Turn on main spray power.

8. Place individual boom solution valve switches to the “ON” position.

9. Slowly move the hydrostatic control lever forward to obtain the desired ground speed.

10. Frequently observe the pressure gauge. When it drops to zero, or spray pattern deteriorates, shut off main spray power, solution pump, and agitation system until refilling solution.