1 minute read

Seat and Restraint Bar Switches

Electrical switches in the seat and restraint bar must be closed (operator sitting in the seat and restraint bar lowered) and the auxiliary hydraulics must be in neutral to complete the circuit and start the engine.

Bucket Cutting Edge

The bucket cutting edge should be replaced when it is worn to within 25 mm (1 in.) of the bucket body.

Electrical System

Inspect and check the machine’s electrical equipment at regular intervals. Defects, such as loose connections or scorched cables must be repaired before using the machine.

Warning

Only use proper, original equipment fuses with the specified current rating. Turn off the machine immediately if there are any problems with the electrical system.

Work on the machine’s electrical system must be performed only by a trained technician.