2 minute read
Module A62 - External control (EXT
Module A62 - External control (EXT)
Module A62 - External control (EXT)
Pin Function CCN Component Circuit diagra m Measuri ng variable Directio n
42 28 14 29 15 1
1 Power supply for power F09 Fuse 8a, 8b, 9a, 10a 12 Volt Input
2 ISO transmission pulses (theor. ground speed) 3 Power relay for ISO sockets LX2 Snap-on connection 11a Frequen cy Output
K3, K4 Relay 10a 12V Output
4 Hydraulic valve 1 (white) lower, with external control XCD Snap-on connection 9a Ground Input
5 Hydraulic valve 2 (red) lower, with external control XCD Snap-on connection 9a Ground Input
6 Lighting (parking light) F76 Fuse 9a 12V Input 7 not used - - 9a - Input 8 not used - - 8a, 8b - Input 9 Hydraulic valve 2 (red) raise, with external control XCD Snap-on connection 9a Ground Input 10 Hydraulic valve 3 (yellow) raise, with external control XCD Snap-on connection 9a Ground Input 11 Hydraulic valve 4 (green) raise, with external control XCD Snap-on connection 9a Ground Input 12 not used - - 9a - -
13 Vehicle CAN1 Low - - 6a, 6b 3.2±0.2 Volt eff
14 Power supply (electronics) of EXT module F10 Fuse 6a, 6b 12V Input
15 not used - - - - Output
Module A62 - External control (EXT)
Pin Function CCN Component Circuit diagra m Measuri ng variable Directio n
401264 42 28 14 29 15 1
16 ISO PTO shaft pulses (ISO) LX Snap-on connection 11a Frequen cy Output
17 Not used - - 9a - Input 18 Not used - - 9a - Input 19 Indicator signal, left S16 Switch Indicator 36a 12V Input
20 Worklights F61 Fuse 47a, 47b 12V Input
21 Not used - - 9a - Input 22 Not used - - 9a - Input 23 Not used - - 9a - Input 24 Start hectare counter, with external control XCC Snap-on connection 9a 12V Input
25 Not used (never use as a connection) 26 Reference voltage Uref JW Snap-on connection 9a 5V Output 27 ISO-CAN-Bus High (CAN2_H) - - 6a, 6b 2.52V ± 0.1V eff.
28 Terminal 31 -31 -31 6a, 6b 0V (ground)
29 T signal (clock signal) for EXT module - - 8a, 8b T. signal approx. 6Volt eff Input
Output
30 Not used - - 9a, - Output 31 Hydraulic valve 4 (green) lower, with external control XCD Snap-on connection 9a Ground Input
32 Hydraulic valve 1 (white) raise, with external control XCD Snap-on connection 9a Ground Input
Module A62 - External control (EXT)
Pin Function CCN Component Circuit diagra m Measuri ng variable Directio n
42 28 14 29 15 1
33 Indicator signal, right S16 Switch Indicator 36a 12V Input
34 Not used - - 9a - Input 35 Not used - - 9a - Input 36 Not used - - 8a, 8b - Input 37 Hydraulic valve 3 (yellow) lower, with external control XCD Snap-on connection 9a Ground Input
38 Not used - - 9a - Input 39 Not used - - 9a - -
40 Vehicle CAN bus High CAN1_H - - 6a, 6b 1.9±0.2 Volt eff
41 ISO-CAN Bus Low CAN2_L - - 6a, 6b 2.49V ± 0.1V eff.
42 Terminal 31 -31 -31 6a, 6b Ground Input