Parameter Summary
Push Protection Full, Partial, None
Options for protecting conveyor: Full is best option.
Delta Protection On, Off
This determines whether the delta action is allowed during the push cycle.
Abort Dist 1-6
Distance on each side that will abort if a shield is left back.
Max Time
Max time for push to complete.
2000-9000
Bankpush Start Group 1-10
How many shields that will come on at start of Bankpush.
Locking Push key For Time, For Stroke
Lock-Push Key works for time or stroke.
Locking Push Tgt Stk 1-100
Sets target stroke for Lock-Push key.
Headgate Push Ctl 1-10
Number of HG shields that push evenly at the same time. If set to 5, then #5 controls the HG push.
Headgate Push Group 1-20
Number of HG shields that are not allowed to push farther than the ‘HG Push Control’ shield.
Tailgate Push Ctl 1-10
Number of TG shields that push evenly at the same time. If set to 5, then 5th shield from TG controls the TG push.
Tailgate Push Group 1-20
Number of TG shields that are not allowed to push farther than the shield that is ‘TG Push Control’ from the TG.