Parameter Summary

Next Article
Reed Rod

Reed Rod

Push Protection Full, Partial, None

Options for protecting conveyor: Full is best option.

Delta Protection On, Off

This determines whether the delta action is allowed during the push cycle.

Abort Dist 1-6

Distance on each side that will abort if a shield is left back.

Max Time

Max time for push to complete.

2000-9000

Bankpush Start Group 1-10

How many shields that will come on at start of Bankpush.

Locking Push key For Time, For Stroke

Lock-Push Key works for time or stroke.

Locking Push Tgt Stk 1-100

Sets target stroke for Lock-Push key.

Headgate Push Ctl 1-10

Number of HG shields that push evenly at the same time. If set to 5, then #5 controls the HG push.

Headgate Push Group 1-20

Number of HG shields that are not allowed to push farther than the ‘HG Push Control’ shield.

Tailgate Push Ctl 1-10

Number of TG shields that push evenly at the same time. If set to 5, then 5th shield from TG controls the TG push.

Tailgate Push Group 1-20

Number of TG shields that are not allowed to push farther than the shield that is ‘TG Push Control’ from the TG.