Stopping SRB

Next Article
Pressure Sensor

Pressure Sensor

Press to see

S R B : * t o c h g p o s , S t o p K e y t o s t o p S R B .

Press

(The display does not change.)

Pressing the Star key (0-key) moves the manual position to the operator’s shield. To confirm this and mark the shearer position, the Jumbo LED, immediately above the IR receiver window will be lit.

Press to see

or

S R B : * t o c h g p o s , S t o p K e y t o s t o p S R B .

S R B F A C E A U T O M A T I O N T o s t o p , p r e s s S t o p .

(manual tracking mode) (IR or serial tracking mode)

Press to see

S R B C a n c e l l e d

Pressing the SRB key and the Stop key is the recommended way to stop SRB if there is no emergency. Shields that have been triggered will complete their Autosequence so they will not be left off the roof. SRB can also be canceled by pressing the Quickstop button on any face PMC-R. In this case, all shield movement stops immediately. When SRB is canceled, all shields in the SRB Area (defined by parameters "Beginning Shield" and "Ending Shield") will "notice-beep" and will show the SRB Canceled display message.

Parameters "Beginning Shield” “Ending Shield”

Note: If Serial shearer position stays in one position for a set time, SRB will shut down. A new start or a restart can be done when the shearer position changes and a direction is identified.