4.2.4 Connecting the motor and sensor cables

4.2.4

• An appropriately designed controller and speed monitoring system must be used to ensure that the maximum speed is not exceeded (refer to chapter Error! Reference source not found.).

Connecting the motor and sensor cables

F motor and sensor cables in the or information about installing and connecting the ools required for this purpose, refer to vehicle as well as a description and the use of the t the vehicle manufacturer’s separate instructions. information must additionally be heeded: The following • The connection leads must not be damaged. • for free laying or 5 x d for fixed The bending radius must be a minimum of 10 x d laying. • The silicone cable covering must on no account be damaged when the motor cables are stripped or else it will tear. The protective fabric and the shielding are only allowed to be cut using shears or a special tool.

Make sure the shielding is properly contacted over the full 360° when the cable gland is connected.

If parts have been removed again. We recommend that you ask your local Siemens Service

Center for assistance.

• Take suitable steps (e.g. seal with a cloth) to prevent parts from falling into the motor when the terminal box is open. are dropped inside the motor, it must on no account be operated until they

CAUTION

The main terminal connection must comply with the applicable standards and guidelines!

Danger Incorrect connection of the motor can result in fatal injuries!

The information contained in the accessories pack drawing no. A5E03039147A

must be heeded at all times.

Fig. 4.2 Detail of the accessories pack drawing, connection diagram for swing motor