OPERATING INSTRUCTIONS RH 90 C E Inspection and servicing

Greasing the electric motor

Grease the bearings at regular intervals while the electric motor is running.

Drive end

Unscrew brass plug (arrow,Fig. 3-17:), which is accessible through an opening in the flange mount.

Add new grease through nipple (1, Fig. 3-18:) until new grease emerges from bearing housing.

Wipe old grease away from the housing.

Fan end

Remove screws from grease relief plunger (3, Fig. 3-19:).

Pull out plunger (3) completely. This is necessary for removal of all old grease

Wipe off old grease and replace plunger (3) fully.

Add the same quantity of new grease through the nipple (2, Fig. 3-18:) as was removed by the plunger.

Pull out plunger (3) again and remove old grease. Repeat this operation until new grease emerges on plunger (3).

Put plunger in place again (3) and screw in securely.

Further information on the described servicing work on the electric motor is given in the operating instructions issued by the motor manufacturer.

Other servicing works

Any other servicing work beyond that outlined above is carried out by the Terex|O&K After-Sales Service or by the motor manufacturer's agent.